Loading...
HomeMy WebLinkAboutPermit File 1506 10th Street c's-'r Y C Cityof Anacortes_ Permit#: BLD-2013-0076 904 6th Street Issue date: 03/08/2013 r x.:, P.O.Box 547 Expire date: 09/04/2014 '., '0 Anacortes, WA 98221-0547 41111 0 ,�+� /`bK (360) 293-1901 Job Address: 1506 10TH ST Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-1926 Project: APN: P55842 Remarks: Addition to residence. Owner: LEWIS PHINNEY Contractor: Address: 3010 ESCAPARDO CIR Address: COLORADO SPRINGS CO 80917 Phone: (719)332-3562 Phone: License#: General Information: Fees: Building Valuation 35000 Building Permit Fee 492.75 #of Lavatories 1 Plan Review Fee 320.29 #of Ventilation Fans 1 State Building Code Fee 4.50 #of Showers 1 Mechanical Permit Fees 30.75 #of Water Closets 1 Plumbing Permit Fee 41.00 Total Calculated: 889.29 Deposits/Receipts: 0.00 Total Due: 889.29 -0 1- frA CA C.i it• i�i fi- i, - I fty U'' C:? !mot CI -4 I t IA Cad C S t w, 4A. f-.. CO t•.? THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF!; CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. .• " HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL , PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR N-• NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. •..0 SIGNATURE OF OWNER OR AUT D AGENT ISSUED BY FrAreED I i i„„L,) lA ivnot t r, l Mechanical Fixtures er FEB 1 5 2013 fnrr Fuel Type s� a ; . `� �6�.: ..w. 1E1 Natural Gas ❑ Electric ❑ Wood ❑ Propane Gas El Other Type of Equipment Number of Type of Equipment Number of Fixtures Fixtures Furnace<=100K BTU Gas Fireplace Boilers/AC/Heat Pump Other Units Gas Outlets Ventilation Fans Gas Water Heater Range Hood Commercial Plumbing Fixtures Type of Fixture Number of Type of Fixture Number of Fixtures Fixtures Toilet Utility Sink Dishwasher Hose Bibb Hand Sink j Water Piping Kitchen Sink w/Disposal Additional Fixtures Clothes Washer Electric Water Heater I HEREBY ACKNOWLEDGE IF HAVE READ THIS PERMIT APPLICANT AND STATE THE INFORMATION IS CORRECT,AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING ACITIVIES COVERED BY THIS PERMIT APPLICATION. WITH THIS PERMIT ALL CONTRACTORS AND SUBCONT RS SHALL HAVE A CURRENT WASHINGTON STATE CONTRACTORS LICENSE AND A CITY BUSINESS LICENSE. STOP WO HERS WILL E ISSUED ON JOB SITES WHERE CONTRACTORS/SUBCONTRACTORS ARE WORKING WITHOUT PROPS a � r j df�f4i/ ANT'S IGNATF RE DATE Last Updated 11-29-05 1. £ 1513 t� drafting Property Line 60.00' Alley ------------- I e� 11 u a 1115 (e) Garage C5ca I `el Jonathan Richards I I 5105 Sterling Drive Anacortes,Washington 98221 (e) Patio - ph 360.391.0832 Establish And Preserve em jonathan_590ho1mail.com Benchmark For Elevation Control I (Refer To Elevations For Height) b 0 Project Description: o Connect New Downspouts Into ' 'jr ' ' Addition To An Existing Existing Drainage System c i - ? ' ;;' EXISTING RESIDENCE FOOTPRINT 802 SF Single Family Residence =r / EXISTING GARAGE 660 SF 10 1 p EXISTING WALKWAYS,DRIVEWAYS 193 SF A O.a. t5 A I NEW ADDITION FOOTPRINT 327 SF P. , w, [1506] i TOTAL IMPERVIOUS 1982 SF l)(e) Residence ' LOT AREA 6000 SF N I 0LOT COVERAGE 1 33% N 15 ' I O. N _ i. Lomi 0O 20'Setback O 0mC .S _ Property Line 60.00' I ® Illlllimi N a (e) Concrete Sidewalk CD IRMINI N Gravel Parking Water Meter Power Pole a)--..-,,—.--_---._.-.------------- o 2 8o co 10th Street C Lir) Q u e p T Site Plan -- ' 0 5 10 20 30 Scale:1"=20' • 0 A 1 ____ i£ li FEB 1 5 2013 ' Phinney Addition 1506 10th Street Anacortes, Washington draftw ±1 & desjgn ac 6, February 2013 ,, NEW ADDITION MODIFIED AREA EXISTING TO REMAIN ENGINEERED TRUSS ES PROJECT INFORMATION: Jonathan SdnDflve Richards Anacortes,Washington 98221 1 Project Description: Addition To An Existing Single Family ph 340.391.0832 12 Residence ern Jonathan 59®holmnll,com a I Building Official: Skagit County, Washington Project Description: ® i___ —sr sf_ I -1 I L Addition To An Existing I Building Classification: Type V-B (NON-SPRINKLERED� Single Family Residence i 8'-1i18 L ' Zoning: R3 - Old Town District Plan information: Bedroom Closet Hall Bathroom 7' 0" Crafts Room Parcel# 135533 9 12"TM Wi'P Title Holder: Lewis & Bonnie Phinney Existing Floor 1 786 SF I // 3/A"T.tgPlwood Li 3010 Escapardo Circle Existing Floor 2 380 SF + - -- Colorado Springs, Colorado 80917 Total Existing 1166 SF �_ - AddlNon Floor 1 344 SF Beam Per Par: Addition Floor 2 359 SF Contact: Lewis & Bonnie Phinney Total New 703 SF 3010 Escapardo Circle Total Heated 1869 SF ryplcaiHea•Header Colorado Springs, Colorado 80917 Dools Ana Windows 8'-101/2" 9'-i" Great Room Laundry Kitchen Living Room Project Location: 1506 10th Street -9 1;2„T I Wi r Anacortes, Washington 98221 Tjai i * _ --1 __*_ .__I+ ——, % 3/4"Tag P:ywood Skagit County �.. ,� - i j i Tax Lot Number: P55842 F` -I I Crawl Space ,�_E z�•LR. I n ul Li Li Legal Description: LOTS 17 AND 18, BLOCK 130, ANACORTES, fI RECORDED IN VOLUME 2 OF PLATS, PAGE 4, 0) Building Section AA RECORDS OF SKAGIT COUNTY, WASHIGNTON. 0) N N 0 2 5 10 Plan Note: Plans Are Ta Be Reviewed By All MIMR a • Scale: l/8"= 1' Subcontractors Prior To Starting �/� C • Construction. If Discrepancies Exist Please t/ / 2 Contact The Contractor For Further ,' •\\ \ 12 ',, G Information. n re C �_ elm VI /// \\\ O / \ / \ \ / \ 11) SCOPE OF WORK: -t o `• � Complete Application New Addition To SFR O C) • C In < \ \ Property Line ao.00' Alley O IS \\ \\ I J dI1U \ \ �e`°`" � i CODE BREAKDOWN: \ �, (e)Garage n o �co \ I le\l Lo E • \\ \ = o„ -o i \ - 2009 IRC INTERNATIONAL RESIDENTIAL CODE \\ \\ 12 (e) Patio 38-1" SO'-1 1/2' 2009 IEBC INTERNATIONAL EXISTING BUILDING CODE v \ 1 4 Establish And Preserve o \ \ Benchmark For Elevation Control�o i 2009 IMC INTERNATION MECHANICAL CODE d \ \ (Refer To Elevations For Height) �_ _ I 2009 UPC UNIFORM PLUMBING CODE \ O o ,+ ,R \ "S \. Connect New Into o Addition • -- �-o'" 2009 NEC NATIONAL ELECTRICAL CODE `\ ExistingDain Downspoutsstem 2009 WSEC WASHINGTON STATE ENERGY CODE Revisions: ------3!'-0”----..- -r ; - EXISTING RESIDENCE FOOTPRINT 802 SF Print Date 2/6/13 ;� p EXISTING GARAGE 660 SF 9 E p EXISTING WALKWAYS,DRIVEWAYS 193 SF / i G a NEW ADDITION FOOTPRINT 327 SF ,�t. Beam Per Plan a .S-._. . I « ltl ! !',, - .," .- TOTAL IMPERVIOUS 1982 SF 1 ' 't 1ryt'r� [JFi�}�71 t,FF, I (-( U rt tt ���''']]] a (e) Residence ,t- LOT AREA 6000 SF -!' X�a�;1'»»'"& ' c 10'"Tread N Lu l I L LOT COVERAGE 33% Ft I_„ , Bearing`Nall/ Reeder r 0'Setback — — — �lJiJRi 5 ? � • 0 6�_ /O ( I ., 3 A:. index: 7 3(4" Riser 39' 10` PFyf�i7.'E t ,r_lv A1.0 x -1 _" ^t Cover rBuildinP Page/Site Sections A1.0 A1.0 t;)B.iEC T C? (�!= Foundation Plan A1,1 9'-8'Floor To Floor 12'-3" l.+J fA3 t'i»{;T1C�PI. C15i:=r';t' t ® 1J�i 1` ' T �`i�t OF CODF iS FL r 2nd Floor Framing Plan A1.1 © } + i 7;I_, I�t 4 5, Roof Plan A1.1 Property Line 60.00' j / 1st Level Floor Plan A2.1 2nd Level Floor Plan A2.1 (e) Concrete Sidewalk Legend: Devotions A3.1 LT e Gravel Parking Water Meter? Power Pole Existing Wall I ��///� New Wail Cover Page I ���. / � Wall To Be Removed {Light} Site Plan Building Sections 10th Street I __ _ _ _ Wall Of Floor Below Si R r pi/ New Item Stair Section /N Site Plan . (el Existing Item 0 1 2 5 I 0 10 25 5I 0 Detector As Labelled A1 . 0 I Ventilation Fan Scale: 1"=20' Scale: 1/2"= 1' 24' 0" FOUNDATION / FLOOR FRAMING / ROOF PLAN NOTES: 10'-0" 4'-C' 10"-0" 1. PLANS TO BE REVIEWED BY ALL SUBCONTRACTORS PRIOR TO / Gable End STARTING CONSTRUCTION. IF DISCREPANCIES EXIST PLEASE • CONTACT THE OWNER, GENERAL CONTRACTOR, OR THE r -- st 12/12 Slope-# --a.<4 Columns (2 PL) ' ► Roof Trusses For New Structure DRAFTSMAN FOR FURTHER INFORMATION.ALL CONSTRUCTION Dropoed/Hanged Joists i '� d rafttin See DeIai 3n s Pace I I ABU44 Footing Connection E[ a T E #' / TO MATCH EXISTING CONDITIONS, VERIFY PRIOR TO Q, L -J L - J C C044SDS2.5 Beam Connection VL design LC 0 48'Sq,Carcrele1 r a• �/ CONSTRUCTION. op r 'd r m Landing D" C,H.TYP ,Match Existing I v I I 1 2. MATERIALS TO MEET THE FOLLOWING GRADES: T __ _ •DS HEADERS TO BE 6X10 HF#2 UNLESS NOTED OTHERWISE. J- ` 1- I ) ) ) 1 ( ) 1 I I a * r -1- -I- p q - - - - _ GLAM BEAMS TO BE DF SPECIES AND HAVE A 24F-V4 RATING. r COLUMNS TO BE DF#2 OR HF#2, y • FT--, �;-T- �1- a - + - --{- + - -T- -, - _ '-Typical Foundation 'gents: I • I I I I I Jonathan Richards 1 I r-, • I II III I I 1 1 1 - Space 24"Flum Comer, I I 1 1 I I f 1 f 1 f I I I ORDP AND TYPICAL FRAMING MATERIALS TO BE DF#2, HF#2, 5105Sterling Drive i I I ! I I I I I I I I I I I I Anacorles,Washington 98221 And Away From 0 0- I I 1 1 1 1 i 1 1 I I I Reinforcing. I 1 I I I 1 I I N 3. ALL BOTTOM PLATES AND ANY LUMBER IN CONTACT WITH ph 360.391.0832 dawl $pa e I I ( Provide Retaining Barriers ca c� em Jonathan 59®aohnar.com I I I I CONCRETE MUST BE PRESSURE TREATED. • I ( I I I I I " • where Necessary I ! 1 I I I I ! °la ' °' J 2 I I lith [{Anil VK�por(ic ie1 a Roof Ridge Line With Ridge Vent r ' - I 2 C I I I I I I I �__��''� , NEW FRAMING u 1 , �' FOOTING THICKNESS TO BE 16"AND DEPTH OF 8" WITH 1, , „ I I I r 4, TYPICAL OTIN THI KN A Protect Description: 91/2 TJi 110 ca 16"O.C. ( I ( 1 '� I , '-4 1/2 711 110 4 16'O,C. I I I I C THE TYPICAL FOUNDATION WALL THICKNESS TO BE 8" UNLESS o I I I I I 1 I I I I I I I o 1 m NOTED OTHERWISE. SEE DETAILS ON THIS PAGE FOR FURTHER Addition To An Existing ' I I ` I I I I I I I ( a_ -, INFORMATION. Single Family Residence i t 1 I i I l i 6 9 3/4" 6' 0 1 6 0 5'-2 t/4" I I I I L c __ _ -.-Use IUS Se€ies Simpson Face Mour:- I %� m /,- - , -- 4 5. ANCHOR BOLT PLACEMENT WILL BE EVERY 48" O.C.AND A -f- I € • I I 1 -I I o - - i ( - - I ��T~ Hangers Or. Flush Connection on `© of MINIMUM OF 2 PER WALL. I . I I 9 I I • I ! I - a° ql. Plan Information: �. -i T'" I I 4x0 m 4O Bum 1 I tpg I �4- x{ $12.a•r --r42(221,41,71‘ats_ o_ :- - 7.. r �- F-1T I L_ _1 �4 - -_i r-_1- L - - - -'- - - - - J Parcel# 135533 I I I ' ?- _ H - - - 2- - 1 6. CRAWL SPACE TO BE VENTILATED BY FOUNDATION VENTS. r Bea rg Wall -3.125x9 Glam Beam'.,- - -1 L - - - - r - 1 r - jr(I I I , E I l I ( ; PROVIDE 1 SF PER 150 SF OF AREA (4 MIN. PER 440 SF).VENTS Existing Floor 1 786 SF I I I I r --__--. I • I MUST BE COVERED WITH 1/4"CORROSION RESISTANT WIRE MESH. Existing Floor2 380SF \ I ; ( m I I I II I I I I I 1 LOCATE AWAY FROM ANCHOR BOLTS AND HOLDDOWNS. 7oial Exfsring 1166 SF I I I I I - -- - - -"- - -- -- - i I- -1 II I � _ _ - - � L- _ _ _J } I N' 4x4 PT Posts To I 4x10Berm [ . i E [ IF - __ _ _ a I SupportBerm I -.-- I r a - -- -- -- - - - I I I 4r12 S c'oe a Addition Floor l 344 SF I I Sew Note IO I • I / �, I X ' - - - m - - 1 I� c 1 - -- 12/12 Slope • 7. 4"CONCRETE LANDINGS TO BE 1/8"LOWER THAN THRESHOLD. Addition Floor 2 359 SF 0;1I L J Frcm.in"hoot 9e xisrng Floor' } N I - I )- Kc I I I \ I I SLOPE AT 1/4"PER FOOT AWAY FROM BUILDING. Total New 703 SF I 9 Bearing Wall To SFr - - _ --- -- ...._.. --__ _._. _- .._..._Nr I i{ v L _ I Extend Roof-Match Existing -- , Beam With Flush Hanger ,. ,- 1 I r I B. PROVIDE FULL BEARING UNDER ALL POINT LOAD LOCATIONS Total Heated 1869 SF n - - - - --- - - ( \T r (Simpson Supplementaln Connection. N 1 (BEAM & HEADER ENDS). t Add Joists I I As Necessary. -- { - N L ' J I I a I I 9. PROVIDE BLOCKING ABOVE ALL BEARING WALLS AND BEAMS. -7,N.t L- - - - -- -- - - ------ ----(-- /,, .. o _ 4 - 11- t I i DSL - -- - �1 r 1_/12 Slope 10• POSTS AT NOTED LOCATIONS.4X4 PRESSURE TREATED DF# NG BEAM ITH A - - - - � Existing CTaWIS Space I II I_. I O16DNOAIS. USEDFOUNDAPONIWALLFOOTI FOOTING n POSTS TO AND J I II- 1 I It n 11 1 �1 POSITIVE CONNECTION TO POST. 4' 0 17 t 7 (I ----. -.-.._ _---.-. - - -� ce •rll-.".- 4112 Slope \�G`// I a I I 11. FOLLOW ALL TJI FRAMING DETAILS PER MANUFACTURER. Lif f II I ._ - - - _ _ _ -- - -- -1-� I � II _ _, I mlim IL_ - - - - - - - - I - - - - _ - - - - _ I I I I r r I 12. FLOOR FRAMING TO HAVE I/4" BEAD OF CONSTRUCTION I- - D D -� I I L _ 1 r- _ - - - J ADHESIVE WHERE ATTACHED TO 3/4"TONGUE AND GROOVE 11) C ` r 1r -, j L - .- _ JL = Ji- Jff fir _ - i SUBFLOOR. 1 fT T1 Iraw ' may I I I EXISTING FRAMING L_ _ _ I N I - L -- - - - -"I - -"- - --- - - --"- -J{ L -- I 13. ADD AND ALIGN JOISTS TO ACCOMODATE FOR PLUMBING. N 7t7 O I � II I L ® I o • L -- - - - - _ .._ - .- -._.___._._ - _ - _._._ c R� Q• µ [ I {' ri 0 14. PROVIDE FIRESTOPS AT ALL APPLICABLE LOCATIONS, INCLUDING L J z I 1 I u HOLES AND ANY OPEN AREAS. C t �_.._. - -"--- - - --. -- -. ._.. - - - - -1 'a 6/12 Slope Ir► a I e v 15.STAIRS TO BE FRAMED WITH MIN (3) 2x12 STRINGERS, ONE AT a)I I EACH SIDE AND ONE AT THE CENTER.PROVIDE FIRE STOPS C � -- -I --- --- - -"-" -- - - - ) 12/ 2 Slope I BETWEEN STRINGERS AT TOP, MID, BOTTOM, AND BETWEEN km� I STUDS ALONG THE RUN OF THE STAIRS.SEE DETAILS. N MIIMI I ® { I I I I 16.ROOF TRUSSES TO BE SHEATHED WITH 1/2"O.S.B. WITH 30# FELT FI I I 1 AND TILE ROOFING. CEILING LID TO USE 5/8"GYPSUM --I .-.-.-,_--_ .__- _ ._.__-- I WALLBOARD. MATCH NEW WITH EXISTING. I1 12/12Slope -}''_". -110" J at r=-0 a_=_ J 17. PROVIDE ROOF CROSS VENTILATION FOR EACH SEPARATE I - 1U I SPACE, AND CONTINUOUS RIDGE VENT PER 2009 IRC.TOTAL NET %Clu r 11 r - - -- - - -- - - - - - - - - - -'- - - - - I Gable End FREE VENTILATION AREA SHALL NOT BE LESS THAN 1 TO 150 OF O a I _ _ - - - - - i n THE AREA OF THE SPACE VENTILATED. C _-_._--_-.._ -_ N L I N $ 18. FOLLOW ALL TRUSS FRAMING DETAILS PER MANUFACTURER. la CZ I I I I I of. I I `" I _ __ I I- -'- -'- - -'- - -'- I -'- -'- - -' - -'- - '-fl II 19.ALL ROOF PITCHES ARE TO HAVE SLOPES AS NOTED.VERIFY - t J I l L \ / - 1 - - � - -- J I- - } L L 6 , li - -- HEIGHT WITH TRUSS ENGINEER TO MEET HEIGHT RESTRICTION. SEE \ / \\\` 12l12 Slape�► ELEVATIONS. o \` 20. PROVIDE ATTIC ACCESS THRU 22"X30"MIN OPENING o Gabe End WITH REMOVABLE PANEL. FRAME WITH 2x12 MEMBERS. c TFoundation Plan T 2nd Level Floor Framing T Roof Plan 21. ALL OVERHANGS TO MATCH EXISTING (12") U.N.O. rw I 0 2 5 10 I 0 2 5 10 I 0 2 5 10 22. INSULATION TO MEET THE MINIMUM PERSCRIPTIVE REQUIREMENTS OF THE 2009 WESC. INSULATION VALUES ARE AS FOLLOWS: Scale: 1/8"= 1' Scale: 1/8"= 1' Scale: 1/8"= 1' CEILINGS R-49 OR R-38 ADV. Revisions: EXTERIOR WALLS R-21 Print Date 2/6/13 JOIST FLOORING R-30 rlr s7Ca ' r _ CONCRETE FLOOR R-10 ( SIDING PER ELEVATIONS ASPHALT SHINGLE ROOFING zMAX (OR USE-Y3# FELT BARRIER) 30#FELT,NTERWOVEN SIMPSON ITS TOP FLANGE HANGERS #15 BUILDING PAPER 1!T OSB SHEATHING 1/2"CDX PLYWOOD SHEATHING 3/4"T&G PLYWOOD SUBFLOOR )CZ.. PRESSURE TREATED 2x8 RIPPED FOR 1/7' VENT BAFFLES BETWEEN TRUSSES AIRGAP 30# FELT OVER SILL INBETWEEN W/ 1"MINIMUM AIR GAP .. TREATED WOOD AND HANGER „nisi TRUSS PER PLAN J �T� �� � \ #4 CONT.TOP BAR, U.N.O. - \1 VENTED BLOCKING BETWEEN TRUSSES Index: U ili ' -GRAD \% Building Sections A1.0 VENTED SOFFIT TO MATCH EXISTING Cover Page/Site Plan/ A1.0 GRADE o ( PRESSURE TREATED POST PER PLAN Foundation Plan A1.1 . --- III - - _ 4"CONCRETE PATIO `, 2nd Floor Framing Plan A1,1 1/2" AIR GAP _ - I I ( SIMPSON AB66 COLUMN BASE 2X CEDAR OR SPRUCE FASCIA Roof Plan A1.1 OR SIMILAR 1st Level Floor Plan A21 FLOOR JOISTS PER PLAN - I p RELATIVELY IMPERMEABLE 2nd Level Floor Nan A2.1 W/R-30 BATT INSULATION . I I - - - LAYER TOP SOIL \ _ i --- I . 7 q 12 c? 1 r 5"CONTINUOUS Legend: Elevations A3.1 ' METAL GUTTER #4 VERTICAL REBAR a, .6,6. 1 ' " -•`- Ex sti g Wa l n v TIGHTLINE STORM DRAIN 8"SONOTUBE 48"O.C.. U.N.O. e , z PER ROOF PLAN• z 0-0Cf//i%( New Wall '�'v* '._... -� W II T B R ( ) 2nd FIoo�Framing Plan n Plan VAPOR BARRIER .,,r,.#a 2 5"•" ' DRAINAGE GRADE GRAVEL FOOTING PAD ' " a o e emoved Light Roof Plan Vittorio PER PLAN INSULATION PER CODE Wall Of Floor Below a. ut✓elm e " .. - - - - - ~ _ r.� FOUNDATION DRAIN - - - � : " AIN 1 - ��" \ \ HURRICANE CLIP PER TRUSS (n) New Item (2) #4 CONT, - I -_ - i PER PLAN (24'.TYP UN())I ( SIDING PER ELEVATIONS BOTTOM BARS, U.N.O. / / UNDISTURBED NATURAL SOIL 4' - -. ,i� e) c 3." ,ti Existing Item /.._./r OR ENGINEERED FILL €& Jeteclor As Labelled A1 • 1 ( - �, Sonotube Exterior Column Support Scale: 1" 1'-0" -- Iventilation Fan Foundation Detail scale: 1"= 1'-0 rp , Roof, Truss Connection S�a,e: , = ,'-0 �A1.91Th " ' \A!1 FLOOR PLAN NOTES: - 8 0 1. PLANS TO BE REVIEWED BY ALL SUBCONTRACTORS PRIOR TO .te II r0 m STARTING CONSTRUCTION. IF DISCREPANCIES EXIST PLEASE " e "':•-•—` CONTACT THE OWNER,° , OR THE o DRAFTSMAN FOR FURTHER E NNERAL FORMATTION.ALTLOCONST CONSTRUCTION d raft i n i coL m` a =a a ^ CONSTRUCTION.TO MATCH EXISTING CONDITIONS, VERIFY PRIOR TO des• „At ..- Lc O ? O LL '� II II _ v II 13 o F. o ° Legend: ; o c O r m a` a a 2. MATERIALS TO MEET THE FOLLOWING GRADES: 6 ' : c a a `° HEADERS TO BE 6X10 HF#2 UNLESS NOTED OTHERWISE. t c t p n O it:, Existing Wall GLAM BEAMS TO BE DF SPECIES AND HAVE A 24F-V4 RATING. v " %/////// New Wall COLUMNS TO BE DF#2 OR HF#2. vl ve o o ob .°' c m STUDS AND TYPICAL FRAMING MATERIALS TO BE DF#2, HF#2, Jonathan Richards g .g c Wall To Be Removed (Light) OR SPF. Anacortes,51 SteDrrling 98221 ce j U it 0 - " N _ — — — _ Wail Of Floor Below 3. PLANS AND CONSTRUCTION OF RESIDENCE TO MEET ph 360.391.0832 a O I. O ro O O PERSCRIPTIVE BRACING REQUIREMENTS OF THE 2009 IRC BY em Ionaehan_Stehoemall.com LL 24'-C" ^ '� > > 2 O (n) New Item a-- r 3 w o- CONTINUOUS SHEATHING-WOOD STRUCTURAL PANELS(CS). USE w o ce o [e) Existing lienl 1/2"OSB PLYWOOD SHEATHING TO SPAN FULL-HEIGHT WITH 6D C.) Tr. 0 NAILS @ 6"EDGE NAILING AND 12"INTERMEDIATE NAILING. Project Description: ----(2) 4x4 Wrapped "a "`o N. 6f4 Detector As Labelled LOCATIONSPANELS AND SIZE REQUIREMENTS Columns 24'-0" r: a_ 48"Sq.Concrete - - "-- -" --- -" - - "- - .. . _ __ -_ _.. __ ... .___ .� AND IMPLEMENT.SEE DETAILS. Addition To An Existing 12'-0" v Landing 5'-i 1/2" 2'-9" 4'-i I/T OJ Ventilation Fan Single Family Residence 71-6" 9'-0" / _ _ ' " "" " / / 4' / 4. AL WOOD IN CONTACT (BOTTOM PLATES) MUST BE PRESSURE CS CS 8 ' (B I CS 11,5 Ft Required Min. Length Of Braced Wall D f D) WINDOW SCHEDULECONTRACT WITH RESSSUREE TREATED LUMBER.FASTENERS Plan Information: TREATED WHEN IN q 9 11 .5 Ft Required Min. Length Of Braced Wall EXTERIOR WALLS ARE FRAMED WITH 2X6 STUDS AT 16" O.C.AND a \.....-- -- /////////////////////i//>//// /1//// //////// "- -- --"- "-" "---� ? "-" � ///////i"/ //////iP'-4'/i/// iiiii//iii lam--W//,�i%r%/i %ik` VINYL DOUBLE PANE LOW-E WINDOWS 0.40) Parcel # 135533 / 3C:o8 / For Continuous Sheeting [16 Ft. Provided] % For Continuous Sheeting [19 Ft. Provided ! / j g ] SHEATHED WITH 1/2"OSB PLYWOOD OR BETTER WITH 15# / Zv r 5BUILDING PAPER. ALL INTERIOR WALLS ARE FRAMED WITH 2X4 �_ U / / ID Size Description OtyExisting Floor 1 786 SF • / U STUDS AT 16"O.C. AND SHEATHED WITH 1/2"GYPSUM Existing Floor 2 380 SF c c r ° A 2'-6"x 4'-0" Single Hung1 WALLBOARD UNLESS NOTED OTHERWISE. / IT B 2'-6"x 5'-0" Single Hung 6 Total Existing 1166 SF cr v Den Dining C 6-10 6 6 C 2'-6"x 2'-6" Awning 2 5. STAIRS TO BE WIDTH SHOWN ON PLAN WITH 10"MIN RUN Addition Floor 1 344 SF g 1 s'-e"Ceiling a'•a^Cenng I \ ' D 2 6'x 4-6" Casement 2 LENGTH AND 7 3/4" MAX RISE HEIGHT. TREADS AND RISERS NOT Addition F or 2 359 SF to Carpet Carpet b; 2-0" Master Bedroom r 1E 2'-0'x 2'-0" Awning 1 TO VARY MORE THAN 3/8"FROM ONE TO ANOTHER. MAINTAIN Total New 703 SF N Great Room - 8'Ceiling i 12 MINIMUM 6'-8"HEADROOM. PROVIDE CONTINUOUS HANDRAIL Total Heated 1869 SF 8 8 CIX�ng ,J Carpet / ON AT LEAST ONE SIDE OF RUN.SEE DETAILS, • / ` = / Existing Wall ; Walk-In ` 6. CONFIRM ALL DOOR, WINDOW, FIREPLACE, AND OTHER ca / / / Closet % ROUGH OPENING SIZES WITH OWNER/CONTRACTOR PRIOR TO / /New Heal Runs(Great Room)Into CaoM / floor 2 Supply 8 Return€nto 2nd Hoof attic Space / U ' / I `n oke d % WALL CONSTRUCTION. ALL GLASS TO HAVE A LOW E (0.40) 21'-11" / `r / I Deiactar v j U / 21'-11" N GLAZING AND TO MEET TEMPERED REQUIREMENTS. 1 v '✓ / Gas 4"Drop Ceiling �y 1 7. PROVIDE SMOKE DETECTORS WIRED TO THE ELECTRICAL SYSTEM Furnace HDU2-SDS2.5 Holddown With SST616 or � - BATTERY BACKUP ON OR NEAR THE CEILING OF EACH DRY WASH 5/8"Epoxied All-thread with 8"Embeddment L — — J 4 % C onra' " / c? �,, FLOOR AND IN ALL BEDROOMS. CARBON MONOXIDE (CO) .11 a al✓ Fon I / \ ALARMS TO BE PLACE OUTSIDE BEDROOMS. 0 Laundry - . „ i K: WITH 866 —" A n 9'Ceiling q • �� 8. PROVIDE EXHAUST FANS KITCHENS AT MIN OF 100 CFM AND Up2emove Hardwo ® 1 BATHROOM FANS AT MIN OF 50 CFM. DRYER EXHAUST FANS r Existing Wal {nl • ., a `� SHALL BE INDEPENDENT OF OTHER SYSTEMS AND EQUIPED WITH _ r' 2 PER 468 .J' Remove �� " BACKN \ • - • ' _ -\ Existing Walls MANUFACTURERS RE S SPECIFICATIONS.ALL RAFT DAMPER AND TO BE LFANS TO BE VENTED TO N N / Handrail 3 - ( CO/Stake Ur. Detector THE OUTSIDE OF THE RESIDENCE. FANS ARE SHOWN AS O . 0. 11 j i� 15R•4A73/4" , We ter I i_ is c % I I I Heater m Kitchen Hall L / ` ---- - 9'Ceiling 9. CERTIFIED PREMANUFACTURED WOOD BURNING FIREPLACE WITH ♦_-- R. _ _ ///Y/✓//// g L _ .7i)ii/iii , ///i/i///)i/iiliiL A- 7'CeNng CO CS T I Hardwood "" -- \•. Q•- Hardwood DAMPER AND OUTSIDE COMBUSTION AIR SOURCE DIRECTLY tin 0 C i Linen" Ben=` CONNECTED TO THE FIREBOX. INSTALL PER MANE.SPECS. �% • `V _ inflow Replace EWith Neg T Fan Bathroor+ 9 10. PROVIDE FULL BEARING UNDER ALL POINT LOAD LOCATIONS C 4-0K ___..i Window With New ('� 1 EE V Bathroom Isom __ g / (BEAM & HEADER ENDS). 9'Ceiling �' 7_4^ �, Hardwood _c la Hardwood p. . -- — Remove Existing c 0 , // s c 11. PROVIDE BLOCKING ABOVE ALL BEARING WALLS AND BEAMS. a i Wails tb Extend Dormer 3'-1" ; S . � It � t �( ' `-- _ +-Q al .,_ i— 12. PROVIDE FIRESTOPS AT ALL APPLICABLE LOCATIONS, INCLUDING i� H ' HOLES AND ANY OPEN AREAS. 0 Closet a ¢$ N let o Wall In Line WIhAO— S M1" 13.INSULATION TO MEET THE FOLLOWING REQUIREMENTS: V o "� Exlerld Dormer To Wall Existing Chase 4 CEILINGS R-49 OR R-38 ADV. CO SQ G0 IS-3" 4'-0" EXTERIOR WALLS R-21 C JO / X ST FLOORING R-30 CONCRETE NCRETEE FLOOR R-0 tO Q Bedroom 2 1 9'Ceilingxing Hardwood Living I Crafts Room i 9'Ceiling I V 7'Ceiling Hardwood LI Hardwood ` i I c0 t ! t >�� E MINIMUM 24"WOOD STRUCTURAL— ORIENTATION OF STUD MAY VARY c PANEL SHEATHING CORNER RETURN j u a O 16d NAIL AT 12"O.C.-. GYPSUM WALL BOARD INSTALLED IN a_ ACCORDANCE WITH CHAPTER 7 Entry ���— Revisions: Office 9'Ceiling OPTIONAL NONSTRUCTURAL FILLER PANEL �,'�i 9'Cegng Hardwood " `) Print Date 2/6/13 Hardwood 6d NAIL AT 6"O.G. ON ALL FRAMING / ------ \CONTINUOUS WOOD STRUCTURAL 6 d r LLB -�� MEMBERS AT PANEL EDGES AND 12" PANEL BRACED WALL LINE \\\ / / O.C.ON ALL FRAMING MEMBERS NOT b w j \ ` / AT PANEL EDGES (a) OUTSIDE CORNER DETAIL 1 1/4"DIA. MIN TO 2"DIA.MAX CONTINUOUS HANDRAIL ORIENTATION OF STUD MAY VARY Index: TERMINATE HANDRAIL / Cover Page/Site Plan/ A1.0 AT NEWEL POST DOUBLE JOIST / GYPSUM WALL BOARD INSTALLED IN Building Sections A1.0 ACCORDANCE WITH CHAPTER 7 Foundation Plan A1.1 / Roof Plan dFraming Plan A1.1 1st Level Floor Plan 21st level Floor Plan AA2.1 /� 2nd Level Floor Plan ::: W V lr 2nd Level Floor Plan A2.1 ' 0 2 5 10 I 0 2 5 10 i-► _/ Elevations A3.1 Scale: 1/8"= 1' Scale: 1/8"= 1' n 16d NAIL AT 12"O.C. z 1st Level Floor Plan w 10"MIN TREAD HANGERS / 6d NAIL AT 6"O.C.ON ALL FRAMING 2nd Level Floor Plan vt / / MINIMUM 24"WOOD STRUCTURAL �/ MEMBERS AT PANEL EDGES AND 12" PANEL SHEATHING CORNER RETURN i • ° O.C.ON ALL FRAMING MEMBERS NOT • (3) 2X12 STRINGERS >�C AT PANEL EDGES r?, (b) INSIDE CORNER DETAIL 2X4 THRUST BLOCK A2 . 1 Stair Detail SCALE: 1/2"= 1'-o" CONTINUOUS SHEATHING DETAIL R602.10.4.4(1) Scale:1' = 1'-0" drafting . & design LLC -- Fascia And Freeze Board -- Asphalt Shingle Roofing To Match Existing To Match Existing r [24.21 Top of Roof 1 777 Jonathan Richards / -.". 8 -12 5105 sterling Drive / \ `' - _ - / • Anacortes,Washington 98221 / // \\ \ - a — — .._ - [17.81 8' Ceiling Height // i em )oo0 man'596M1olmon.com a [16.31 Header Height 1 t / / / A/ - — <,// . Soffited Eave To -- -- -- % _-_ // f/ I Project Description: ,- / / s Match Exisiting �/ /�/ / / / / ',/ /. i_ Addition To An Existing 12 / 8' 1 1/8" / Single Family Residence / / / / ,/ / , b 8' 24' 0" To Average Natural Grade: / 12 -- -- 12 / - - \ 1 \ ;22' d 7/8" Plan Information: 12 s Parcel# 135533 1 - }- - - - - - [9.7'j Finished Floor - Existing Floor 1 786 SF - - - - -- -- ---{- -' - - - - a _ - - - - [9.1'j 9' Ceiling Height1 r Existing Floor 2 380 SF .- Total Existing 1166 SF y ,, x n /, - - - - - (b.Tj Header Height r / g . '// / / / - - //, // /, - - Addition Floor 2 359 SF - - 'r /. Addition Floor 2 359 SF .i --- - /• % 4_i" i % , Total New 703 SF b 8„ / ; _ - - - Total Heated 1869 SF — mot — z —---'" '^ I - � — [[OD] Finshed Floor l I l —I 1 Lap Siding And Trim -f --Door And Window Casing To Match Existing To Match Existing North Elevation West Elevation Si 0 2 5 10 0 2 5 10 I I I I Scale: 1/8" = 1' N Scale: 1/8"= 1' N N QO }- C tinO m sr N Q 3 rim N N \ 12 V \\ 12 % 12 8 Q c• 4I I IRO a IIII �lll� � ll • \ 12 12 o \ , 12 at 4 - d Revisions: Print Date / / 3 Lx_._ , n /i i //'r // - �/ / // MIA , . . __ 0 "j ; /4, I - --- - H- - - � imma I 1 - - Index: Cover Page/Site Plan/ A1,0 Building Sections A1.0 rril Foundation Plan A1.1 2nd Floor Framing Plan A1.1 Roof Plan A1.1 1st Level Floor Plan A2.1 South Elevation 2nd Level Floor Plan A2.1 East Elevation Elevations A3.1 0 2 5 10 I I 0 2 5 10 I I Scale: 1/8"= 1' Scale: 1/B"= 1' Elevations A3 . 1 1210203-1 0006 04/11/2012 001 3 Permit Fees 009331 $40.18 'VC Y Qom:. City of Anacortes Permit#: BLD-2012-0116 $ 904 6th Street Issue date: 04/11/2012 '*•"' iAlr.+' P.O.Box 547 $ WA 98221-0547 Expire date: 10/08/2013 'U,�r Anacortes, - (360) 293-1901 Job Address: 1506 10TH ST Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-1926 Project: APN: P55842 Remarks: Rebuild deck at front door. Owner: JOSEPH WERMUS Contractor: Address: 752 DAYTON ST Address: EDMONDS WA 98020-3433 Phone: Phone: License#: General Information: Fees: Building Valuation 800 Building Permit Fee 26.25 Plan Review Fee 9.43 State Building Code Fee 4.50 Total Calculated: 40.18 Deposits/Receipts: 0.00 Total Due: 40.18 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDIN• CES OVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT _ -•NTING OF A PERMIT DOES OT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER •TE OR L• AL LAW : LATI CO TRUCTION OR THE PERFORMANCE OF CONSTRUCTION. (24)/ �r AUTHORIZED AGENT ISSUED BY SIGNAT E OF, NER OR AU HO it, • 11.......00...". ., . : „,„1 ,...,,, , . , I el I , . , , 11 . . • . il ,t r•ri i ' • , . ±•`,V ,•' I 1 ' • , .. 1 •• , „ •. I „• / •f „,,,,,,ti re,!'id ) -77.7" : :' ".; '•':I' : ,,...."., '-‘'• ' - •'; ,,••-; -:',--Z''.',1 r i •• C:\ r"::..-••- ' ':**4;"r-,. r * '• -,,•#''''ir- ;.: 777-77".7.":7/-*- " ', N:.- ''1l'... t ,. • , ,:,. ' .:, ',:---:i'',.,..-'''''':'''.1 q iff, -_,'"''''A RJ- 1 A Al--4:, ,,- r - 4 ', .4 . T, I r; : J., ' # 't• - ; 4,----7 • -" i i- i , d• 36- i . . t p- '.. ! ! '1 '• , I ALI_ f'''•':::;;......3 „ I ,__. ._. :' .4cC___ _..., se' ' tE, ,<' ..-i' 9// ' II E •4( --------.--- t:i •-•-,----4---"----4-- ), 4 -. --- -----,----- ---1,-,--,---,-- --4, - -- --4,-.. --.--s, '.., WL........, ,_ - .! ,L D i ET:T .0' -F. E L D,INSPECsT ICN. . -R GH) : ,••••"----------77 '1. CP , ,L ,- , OFCODF N7 : -) 1 -r / 7_.....__,:2-- -_-•-- / ------- ., _ fe7,1.-t. 7L-- fr ." tc1,.-; i, ,'" 4_,.,,,,,,/ 4,4e- .._,:e..,"fri,e /Y: '1,4\ 1,,,....• - , [ / f , ,i. - 1 .jOre:.s*, itieer.„041/ ,r0,44..-‘,...- OT,, ,. /.,- ?I_ ..,-,;si ,, , ,, ....,-:-.:, -5 , -- 1 --•- ---, ..• , t t ) ,t, '-! ow '0740•104+.0A4-4/ >I/ '':•51j 4-,0fre,".50 :___.-4 k•-•'...-,_/_,A.-________ ...-; . - , - - -- 4!'"."' . e) . el <1010eCAe !.' ' W.}0** ' , ' '( •1-4C7 .,or....Li-s I '/ * • ,—— / • . Pre-0.44--, .4,,k-- V 1,,f,,A e:0 ifri/dt' le- bk 4, / , otia.3 Poi "ty 3.,---,-; he -,4,,,:y _/ ay vi, '' (, '1 ti,e - • I 5. 14.7541 021C 4•"" /14= 1--5 L. 4 5 Z,s. A 3/,// rileel. - . 4 5.A4--e V 5"Ak'il-1-,-'4,..rit,:/5 ,c4.4,1 )(7'el'''''‘• ' Z Mg' . I . . ,4ke 57.5-ki.yr i'.4•67.-62,,,,,,„,,,,!‘„/ (2.,,,,,,x, /2_ . . , - 0 i,e....4- leeCi7e".."'" lor-,e- 4./...1 /7:5, 7- 6-r-I, hot-dipfrd .0!.4 / h/7-e-d 54,h te.‘ ,,-.' 15./..te/ wr: -- , . 1-- ... MECHANICAL PERMIT CITY OF ANACORTES PERMIT NO. : MEC94-0057 P.O. BOX 547 APPLIED: 05/13/94 ANACORTES, WA 98221 ISSUED: 05/13/94 (206) 293-1901 EXPIRES: 05/13/95 SITE ADDRESS: 1506 10TH ST ASSESSOR'S PARCEL NO. : 3772-130-018 PROJECT DESCRIPTION: install gas freestanding stove — OWNER — CONTRACTOR RICHARD HALVERSON 1506 10TH STREET ANACORTES WA 98221 293-7178 TYPE OF WORK. . . :ADD BOILERS/COMPRESSORS- DOMES. INCIN • 0 TYPE OF USE •RES 0-3 HP • 0 COMML. INCIN • 0 3-15 HP • 0 RELOC/REPAIR. . . : 0 FUEL TYPES 15-30 HP • 0 CLOTHES DRYERS. : 0 : /GAS/ / / : 30-50 HP • 0 GAS WTR HEATERS: 0 FURN < 100K BTU: 0 50+ HP • 0 STOVE, APPLI. . . : 1 FURN >=100K BTU: 0 AIR HANDLING UNITS-- FIRE LOG/LITE. . : 0 FURN - FLOOR. . . : 0 <= 10000 cfm. : 0 WOODSTOVES • 0 UNIT HEATERS. . . : 0 > 10000 cfm. : 0 OTHER UNITS • 0 VENT FANS • 0 EVAP COOLERS. . . : 0 GAS OUTLETS • 1 VENT SYSTEMS. . . : 0 HOODS • 0 VENT W/O APPLI. : 0 — FEES — NOTES , Code Amount---- By- Date---- Receipt PRMT $ 24.50 DM 05/13/94 2442 TOTAL $ 24.50 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and Laws regulating activities covered by this permit. I4 cam& Issued by Applicant or Owner' s Signature 24 Hour Notice Required For All Inspections mec_prmt, Rev: 06/11/92 BUILDING PERMIT CITY OF ANACORTES PERMIT NO. : BLD94-0061 P.O. BOX 547 APPLIED: 02/16/94 ANACORTES, WA 98221 ISSUED: 02/16/94 (206) 293-1901 EXPIRES: 02/16/95 SITE ADDRESS: 1506 1OTH ST ASSESSOR'S PARCEL NO. : 3772-130-018 PROJECT DESCRIPTION: Replace wood foundation with concrete — OWNER — CONTRACTOR — LENDER RICHARD HALVERSON 1506 10TH STREET ANACORTES WA 98221 293-7178 TYPE OF WORK •ADD AREA (sf) VALU. . . $: 4000 TYPE OF USE •SF LOT • 0 REQUIRED SETBACKS---- CENSUS CATEGORY •434 1ST FLR • 0 FRONT 0 ft ZONING 2ND FLR • 0 SIDE • 0 ft :? BASEMENT • 0 REAR • 0 ft OCCUPANCY GROUP GAR/CARPORT. . . : 0 REQUIRED PARKING-- :R3 :? :? •? OTHER 0 TOTAL • 0 TYPE OF CONSTRUCTION HANDICAPPED: 0 :5N : ? : ? :? NUMBER OF UNITS • 0 COMPACT • 0 OCCUPANT LOAD STORIES • 0 IMPRV SURF. : 0 sf . 0: 0: 0: 0: BUILDING HEIGHT. : 0 ft — FEES — NOTES Code Amount---- By— Date---- Receipt PRMT $ 44.50 MD 02/16/94 19 STBC $ 4.50 MD 02/16/94 19 TOTAL $ 49.00 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Issued by Applicant or Owner' s Signature 24 Hour Notice Required For All Inspections / bld_prmt, Rev: 06/11/92 " FOR INSPECTIONS CALL: CITY OF ANACORTES PERMIT .t''' 092 293.1901 BUILDING PERMIT 24 Hrs. Notice Requested Site Address 1506 I0th NAME(OR NAME OF BUSINESS) I PLUMBING Robert Halvorsen MAILING ADtittESS No. TYPE OF FIXTURE OR ITEM FEE 1508 10th Street CITY TELEPHONE NUMBER Water Closet $ Anacartee, WA 98221 293-6940 Bathtub NAME Lavatory Shower ADDRESS Kitchen Sink Dishwasher CITY TELEPHONE NUMBER Laundry Tray r Clothes Washer NAME Water Heater Westcoast Roofing, Inc. Urinal re iADDRESS Drinking Fountain 1144 S. Burlington Blvd Floor Sink or Drain CITY TELEPHONE NUMBER Slop Sink 8 Burlington, Wa 757-4000 Water Piping STATE LICENSE NUMBER CITY LICENSE NUMBER - WESTGRI11oKH 4575 LN?e}i4eniial ❑ Non-Residential PERMIT $ O New"' ❑Add ❑ Alter OSfjepair TOTAL FEE $ [Muil:ling ❑ Plumbing Q Mechanical MECHANICAL ❑,Sign't ❑ Demolition 0 Other 0 GAS 0 OIL 0 ELECT. 0 OTHER Legal Description of Property or Ilex Account Number Na TYPE OF dLot t 7+18Block 130 of EQUIPMENT FEE Or g nal Plat 3772-130-015- AirCond. Unit $ Refrigeration Unit— HP Boiler— HP Forced Air System— BTU/KW Describe Work Floor Furnace Reroof Residence. Wall Heater Unit Heater Clothes Dryer Occupancy Use Ventilation Fan [Mingle Family Residence 0 Multi-Family Residence Range Hood ❑Office 0 Retail 0 Storage 0 Church Air Handling Unit— CFM . ❑ Restaurant 0 Other Pre-manufactured Stove or Fireplace NOTICE Gas Piping This permit is issued by the Building Official and,under the provisions of the Uniform Building Code,shall expire by limitation and become null and void if the building'or work authorized by such perndt is not com- PERMIT $ menced within 180 days from the date of permit issuance,or if the building TOTA LFEE $ suchpermit is suspended or abandoned at anytime or work authorized byPe after the work is commenced for a period of 180 days. TOTAL FEES VALVATION FEE By affixing my signature, I hereby certify that I am the owner of the Building 3,294 .00 $ 45.00 property for which this permit is issued or am an authorized represen- tative of the owner. 11 provisions of laws and ordinances erns this of work will Plumbing A Ppli herein o not, dine Mechanical be complied with whether specified or including routine calls for inspections. Sign ,ill r - Demolition ,,, _��; ;', G._ �'i;,/l ,.,i l-1,il/i a ,::.i' 97 Energy Surcharge signature of Owns or Authorized Agent (Dew) State Surcharge 4.SO Sued Setback Side Yard Setback Rear YaIPSe lack Other TOTAL S 49. 50 M1M1 Use Zone Occupancy Group Type or Conn. Conditions: Lot Area Vacant Site Dealing Units ❑Yes O No Fht Sprinklers Required No.of Stories Bedrooms occupant Load OYa ONo She of Bldg. Plans Checked By: Wog B,GNED.AND DATED SMART.ThN N YOUR PflMTT Perriiaien is hereby veto do the above • • bark stealing to the aoditiar hereto end amnina to•ths approved plus end 'r '. "•' p therte abject to tetpatoas with the redline/es of the CITY), A(XIRTE8. r f 08/02/31 Permit Issued By>( ' .-..c: Building Official (Due) .win Frank awefgi Pti1 Psi $ Address /574 /?), S.71 Legal Description ic7-5. /71 /eP f3Lk /yen (fix/sue, Assessors Account No. Permit No. Date Description Date Finaled 22 3 5- 6-3a gait` ' �9 3`f 747 =/ 22'x 30 f CA-"Ace 15// @ 36Z3 — kegtot- y?6 c2u, e 5