Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2018-0172 4603 Anaco Beach Road
City of Anacortes Invoice/Permit#: BLD-2018-0172 904 6th Street Applied date: 03/30/2018 P.O.Box 547 Issue date: 03/30/2018 f= C Anacortes, WA 98221-0547 " � (360) 293-1901 Expire date: 09/26/2019 Job Address: 4603 ANACO BEACH RD Permit Type: Fire Sprinkler Permit ANACORTES WA 98221-8708 Project: APN: P61819 Remarks: Install NFPA 13D sprinkler system Owner: STEVEN &TARA NELSON & DOWD Contractor: ADVANCED FIRE PROTECTION INC Address: 4603 ANACO BEACH RD Address: PO BOX 1543 ANACORTES WA 98221-8708 WOODINVILLE WA 98072 Phone: Phone: License#: ADVANFP199B6 General Information: Fees: Building Valuation 12000 Building Permit Fee 209.25 Plan Review Fee 136.01 State Building Code Fee 4.50 Total Calculated: 349.76 Deposits/Receipts: 0.00 Total Due: 349.76 C) i Q t r, !-a ,-1- 1.> Co ri' y. _. 6 .-- --.I d 2> 77 F-f yE =2 ;P. !1 iC, 7 i, •.. m 1- 7 *E. .t 6 -n 77 YL x H Y, Z. ii, 73 4' in CO r- THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITH& 180 DAYr,' 2 CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK1S COMfeIEcEQ.k I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL P!RCE/p.[OttS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR' f�}9TLTt GRANTING OF A PERMIT DOES NOT PRE ,UME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHEFVSThTT LOCAL LAW RE LATING CONSTRUCT! N OR THE PERFORMANCE OF CONSTRUCTION. = :o r.0 r•a '01)/ S GA R I NEL OWNER 0 A ZED AGENT ISSUED BY ....I y.. Fyrrce, Groc From: Fyrrce, Groc Sent: Wednesday, March 21, 2018 8:43 AM To: 'Mike Balsley' Cc: Kennedy,Jack Subject: RE: Nelson/Dowd Residence Hi Mike, Please see the attached plan review notes from Jack Kennedy, for items that need to be corrected so that he can finish his plan review: BLD-2018-? Mike, After reviewing the submitted plans,the following revisions are required: 1. Sprinkler heads will be required in the garage area. (Living space above garage) 2. Water to all toilets to be supplied by sprinkler system. 3. Show horn strobe location and connection to flow switch. Jack.Kennedy Assistant Chief/Fire Marshal Anacortes Fire Department 360-293-1932 Office 360-661-3437 Cell Best regards, Groc Fyrrce Building Inspector/Permit Technician City of Anacortes (360)293-1901 A,7 tc/57frrie%n d (e i2/ouin.itie4//Toeyi; (11/6(11(w aitr/ecyeralrf.�r- My incoming and outgoing email messages are subject to public disclosure requirements per RCW 42.56. From: Mike Balsley [mailto:mike@advfire.net] Sent: Wednesday, March 21, 2018 8:09 AM To: Fyrrce, Groc<gfyrrce@cityofanacortes.org> Subject: Nelson/Dowd Residence Groc, 1 Checking on the status of the fire sprinkler permit for the Nelson/Dowd Residence.4603 Anaco Beach Road. Thanks, Michael Balsley,VP Advanced Fire Protection Inc. (425)483-5657ext113 (206)730-9632 cell 2 oxY fThG,COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT i. -1 o1 & 1M, �tE SPRINKLER PERMIT APPLICATION .Mailing Address:P.O. Box 547,Anacortes, WA 98221 `L FEB 1. 2 2018 Office Location: 904 6th Street,Anacortes WA 98821 COg: � Phone: (360)293-1901, Fax: (360)293-1938 CITY OF ANACOAiTES PLEASE REFER TO THE FIRE SPRINKLER PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS MODIFY EXISTING SYSTEM Q INSTALL NEW SYSTEM 0 UNDERGROUND FIRE LINE 0 PROJECT3 (Street, 'tee `Z oAP PROJECT VALU TION: Parcels)#: IZ,O y "` ?loi et p (I4 Phone: Fax: `�1� ��e¢' {��'cs �a-t 425`4533 'S6s? 42s43.sa-11 Address(Street,City,State,Zip): E-Mail Address: ?-0, ')o'}- 1543 W OoPki-1►/iuk; Lop qg a 7 2 v re Q act V-Cnt. ,tc4. PROPERTY OWNER: Phone: Fax: KA-L.56A-I l IVo LAO Address(Street,City,State,Zip): E-Mail Address: 4(003 A0-1-,r .3 ekc u -Za,A-A i4,41 al-ms CONTACT PERSON: Phone: Fax: rv\tF LSLg-1 306- 730-%3 42r 423-5077 rdress_f4Street,City,State,Zip): E-Mail Address: v- t 5 c3 1.0410 t,--141c4, WA_ 98072 v "ke JLClag*.re. bk e+- CONTRACTOR:* Phone: Fax: VA9 \,9-lic ° C et-- a- ,.1 425-4%3-.S6S7 4?3--4S3-Sol/ ddres Street,City,State,Zip): E-Mail Address 'KO, ls43 WOtkr utu..4, Luvl Q 72 vulict. •ec?elUg./e_ /1—i- *All Contractors&subcontractors must have a valid City of Aate Sprinkler Certificate&License#: Exp.Date: Anacortes business license prior to doing work in the City. ��h-I�� �� 5-1 -2- 9 Contact the City's Finance Department at(360)299-1968. B siness`Li3n2s 6-?(6 Ex3 Date:q COMMERCIAL 0 RESIDENTIAL G OCCUPANCY CLASS: SPRINKLER STANDARD: HAZARD CLASS: Is this work,associated with another project? Yes 0 No 0 If yes,specify: PROPOSED WORK: ( TitL fr / ( rJC PA 13P }�--t Q� {�►,uKlr.� I declare under penalty of perjury that the information I have provided on this foini/application is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of acortes. Print Name: plc ,01 d- L L -1 Owner 0 Agent (specify): Signature: .,_/ Date: �-` 9 - 20/ t PLANNING,COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT L ,f FIRE SPRINKLER PERMIT C ,7ECKLIST Mailing Address:P.O. Box 547, Anacortes, WA 98221 ' Office Location: 904 6th Street, Anacortes WA 98821 co Phone: (360)293-1901, Fax: (360)293-1938 Plans shall be of sufficient clarity to indicate the location,nature,and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: n z O .d c 'cs 5 „• e, C5' SUBMITTAL REQUIREMENTS: Pi) o., `D F The number indicates the number of e. a copies for submittal(if applicable). AD CO U, O '1 5. CD Ni Fire Sprinkler Permit Application 1 1 Floor Plan(scaled construction drawings showing): 3 3 o Location of sprinkler heads,piping size and layout o Interior, exterior and underground fire sprinkler components o Indicate wet pipe or dry pipe system o System calculations &manufacturer's information on system components o Water flow and control valves o Site Plan(showing FDC &PTV locations) Final inspection&approval from the Fire Marshal and Building Inspector 1 J is required once work is complete—Requested by the applicant Underground&above ground installation certificate(provided after / 1 installed) Fyrrce, Groc From: Kennedy,Jack Sent: Tuesday, March 20, 2018 2:05 PM To: Fyrrce, Groc Subject: 4603 Anaco Beach Road BLD-2018-? Groc, After reviewing the submitted plans, the following revisions are required: 1. Sprinkler heads will be required in the garage area. (Living space above garage) 2. Water to all toilets to be supplied by sprinkler system. 3. Show horn strobe location and connection to flow switch. Jack Kennedy Assistant Chief/Fire Marshal Anacortes Fire Department 360-293-1932 Office 360-661-3437 Cell 1 Q UiCK RESPONSE Q,_ i i,4Lt\ai ,L AUTOMATIC SPRINKLERS i I j r_� uI p�Q)1 ,---* l-Jr SERIES 'r r r j DRY TYPE PENDENT -h IrrIf IrrI r' 'i�._'.M uLl IE `1 )l P P I I F! 1 y j ^I i k, rL, , y� ,r 1 DESCRIPTION AND OPERATION ' 2 6 201$ The Globe Quick Response GL Series Dry Type Pendent Sprinkler is — - - - designed for use in special applications such as freezing environments C ANALCif P_ ' and conditions where sediment or foreign materials might accumulate ;=- in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler I� t utilizes a 3mm frangible glass ampule as the thermosensitive element. t This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler ', \ opens releasing the bulb seat, causing the inner tube assembly to _ I` move, allowing the spring assembly to pivot alongside the inner tube. < � -i- a ', At this time, water flows through the sprinkler and is distributed by the . , n, deflector in an approved discharge pattern. It can be installed wherever r1;-- standards spray PP sprinklers are specified but offers the additional feature + I '' pi) p Yp of greatly increased safety to life. Quick Response Sprinklers should y?�.___ '- _ be used advisedly and under the direction of approving authorities , SURFACE SLEEVE &SKIRT /` having jurisdiction. ':. MOUNT - The heart of Globe's Model GL Series sprinkler proven actuating \ assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the �— -_ t liquid within the bulb expands increasing the internal pressure. At the I. prescribed temperature the internal pressure within the ampule exceeds I . >._ the strength of the glass causing the glass to shatter. This results in s water discharge which is distributed in an approved pattern. fi TECHNICAL DATA - ! } o See reverse side for Approvals and Specifications. t, o Temperature Ratings - - 1 135°F (57°C), 155°F (68°C), 175°F (79°C) F-- 1_ „,- _' 200°F (93°C), 286°F (141°C) f4 li' 1 G Water Working Pressure Rating - 175 psi (12 Bars) _., -y_ i • Factory tested hydrostatically to 500 psi (34 Bars) EXTENDED RECESSED o Maximum low temperature glass bulb rating is -67°F (-55°C) o Frame - bronze ° Deflector- brass ° Screw- brass 4 Bulb Seat - brass o Spring - nickel alloy ° Seal -teflon • Retainer- brass ° Pin - stainless steel • Torsion Spring - stainless steel ° Orifice Insert - brass o Bulb - glass with alcohol based solution, 3mm size o 3/4"NPT or 1"NPT o Outer Tube - galvanized steel pipe ° Inner Tube - stainless steel SPRINKLE? TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A.MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C APR 2017 GFS-505a(Formerly A-55) QUBCK RESPONSE AUTO,' lATIC SPr INKLEL S DL SERIES DRY TYPE PENDENT SPECIFICATIONS NOMINAL THREAD SIZE LENGTH FINISHES i1K'1 FACTOR 5.6(80 metric) 3/4"or 1"NPT Factory Bronze _� cULus Variable to 48" Chrome FM Variable to 36" White Polyester2 8.0(115 metric) 1"NPT Black Polyester'•2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 2cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS SIN K THREAD 135°F 155°F 175°F 200°F 286°F NYC-DOB STYLE MODEL FACTOR SIZE HAZARD' (57°C) (68°C) (79°C) (93°C) (141°C) *FM cULus MEA ,_____ 101-92-E NDENT GL5635 5.6 1"NPT LH/OH X X X X X X X X PE RECESSED GL5636 5.6 3/4"NPT LH/OH X X X X X --- X X PENDENT GL8135 8.0 1"NPT LH/OH X X X X X --- X X 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPAI3 AND ANY OTHER RELATED DOCUMENTS. *PENDENT STYLE-FM APPROVED 155°F(68°C),200°F(93°C),AND 286°F(141°C) °RECESSED PENDENT STYLE-FM APPROVED 155°F(68°C)AND 200°F(93°C) LH:LIGHT HAZARD; OH:ORDINARY HAZARD CI!;OSS SECTIONS IMPORTANT INSTALLATION DATA r- '-_' TEE FITTING ///TEEFTITING Globe GL Series Dry Pendent Sprinklers should be installed in V 14%:163 CV5G ISS OR k AN51016.3CV553550R AN6]336.4 CLASG 126 I;/ ANSI 016.4 CLASS 125 rr11 accordance with the requirements set forth in NFPA 13. These `_r, Imo5-_J FA OF lEE FACE OF sprinklers are to be installed using a pipe wrench applied to NG N 1TINM=-1[ ;r I L J I the outer tube. When this is not possible, the proper sprinkler _;� % ;;;r i;.';:;r I. head wrench may be used with extreme care for lengths up to y����f _El_ - 221/4111N.l'NFT approximately 18". Excessive force may distort the frame thus I Al - FACE OF 1f/2'NIL DIA. • CEILINGI °OIE➢ICFIlW6 destroying the unit. �� When installed in a wet system extending into a freezing TWO PIECE 439 MAX. c� /. { c� ' = ESCUTCHEON 3%31 I FACE s OF area see chart on Dry Caution Sheet for minimum exposed ESCUTCHEON 1/4' CEILING barrel length to prevent. ice plugs. Please refer to our Dry ,�/ 2' Caution Sheet for further important installation data. EXTENDED RFAGE M ORDERING llNFoRMA���N s-1 r-t 1 TEE FIITNG I TEE FITTING i I AN6[6363C�-1550R V AN$IP163CIA6- 650R SPECIFY ANSI P16.4C 125 1 ANSI 016.4 CLASS- _ I _ I ° Quantity•Model Number•Style•Orifice•Temperature•Finishes FACE OF L_r� J LNG T o ti i FACE FA. •Quantity-Wrenches-P/N 333010 - 1 I °Quantity Recessed Wrenches-P/N 337014 1 IIII 33/9'MIN.GCERLIIANGI • Escutcheons Desired .A. HGIEN .A. 31/9' IN.3/4NPT 13/4-MIN.3/4.NPT • Quantity-Protective Caps-P/N 327109-cap(Friction Fit Recessed) 23/9' IN.1-NFT �/ 11/2-MIN.1'NPT r @.OA. - i��'■' /� "A"Dimension Distance from face of fitting to the finished ceiling line Al linN°LENCIRID -., , %/ .- regardless of escutcheon used. �/� ^ 3]/32'NM FACEOF /�1 yy���%/� ' fil _1(1; � TWO PIECE 212•MW.CEILING GLOBE®PRODUCT WARRANTY ■ TI ESCUTCHEON q'MA% (/�j` it/4'X. ,'r 1C caENO ,1r Globe agrees to repair or replace any of its own manufactured 2'MAX. CUP RETANER / products found to be defective in material or workmanship for a RECESSED SLEEVE&SKIRT period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). -_- __ -— 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 FAX 989-846-9231 EIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com APR 2017 PRINTED U.S.A. GFS-505a(Formerly A-55) r "� ._,` F RESIDENTIAL&COMMERCIAL FIRE PUMP SPECIALISTS y 6040P12TH AVE. 0RT WT/ALCOFLAND, O N 97220 HONE 800-878 805 IRE.COM HOME HYDRANT U.S.Patents#8,678,032&8,905,069 NFPA-13D Packaged Residential Fire Pump & Tank H H 3- 150 C - ,- __ t. 40GPM @ 40PSI _ 02 • 29 �I1 350 Gallon Water TankA7N -© ll D, Tank Drain /2"(GHT) �._%f 1k .O 22 Overflow Fitting 1"(NPT) -® a3 Auto-Fill Valve 3/4"(NPT _ Applip,11.5HP Electric Motor rm� ��0 g ��� �r'���'� —_ 240 Volt Single-Phase FEB 1. 2018k` 8.1 Amp (Full Load) ` \ism& . 1`1�m/ CITY OF ANACO E /11111W i Ill".........; C' 1 %4" Discharge (NPT) 1I Smart Riser Control System 76 \ =. ® Isolation Ball Valve 2. -aj 'k ® Test Line/System Drain \ tr. 09© 40-60 Pressure Switch i— \ (7 Pressure Gauge `-�='___ - 10 ___ ® Flow Switch \ , r �� ® Discharge Check Valve i� •►ems,.. 0 10 Suction Shut-off Valve ,_ -49 _ PerformancePerformance values based on multiple pump tests.Not for certification purposes. GPM 0 20 25 30 35 40 45 PSI 47 45 44 43 41 40 39 i., "THE INCH" L.AL e -, RESIDENTIAL i AUTOMATIC SPRINKLERS r- EIRE SPRINKLER R ' 4:TI MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a flat plate profile that utilizes a 3mm frangible glass ampule as the thermosensitive element. It features economy, aesthetics and the lowest allowable water flow with a nominal 1" of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of Underwriters Laboratories Inc. as described in UL Standard, 1626, for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. All that is seen at the ceiling is the 3 5/16" diameter flat ceiling plate color finished to match the speci- fier's exact requirements. The ceiling plate is soldered to the sprinkler's special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the residential pendent spray sprinkler. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distrib- uted in an approved pattern. 0 i...: g ft.--2. 0I , , , , ,- i FEB 1. 2 2018 CITY OF ANACORTE ,, TECHNICAL DATA • See reverse side for Approvals and Specifications. eoen • Temperature Rating - 155°F (68°C) i . , b Cyr Aa o . • Water Working Pressure Rating - 175 psi (12 Bars) o Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze o Deflector- brass o Screw - brass • Lodgement Wire - stainless steel o Bulb seat- copper o Spring - nickel alloy o Seal -teflon RESIDENTIAL o Bulb - glass with alcohol based solution, 3mm size FLAT PLATE CONCEALED • Cover Plate - brass o Upper Escutcheon Assembly - steel PENDENT . SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 155°F 68°C 1 RED i 100°F 38°C DEC 2016 GFS-360(Formerly A-10) "THE INCH' RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4 90 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS AND AFFR•VALS SIN NOMINAL THREAD LENGTH FLAT COVER cULus MODEL "K"FACTOR SIZE PLATE FINISHES CE • 1/2"NPT 3" Chrome GL4906 4.9 (68 metric) (15mm) (7.6cm) White Painted X Other Painted Finishes1,2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. °FOR PAINTED PLATES OTHER THAN WHITE,CONTACT GLOBE FOR ORDERING SPECIFICATIONS. INSTALLATION DATA FOR FLAT AND SL•PED CEILINGS** SPRINKLER MAX.AREA OF *MIN. *MIN. MIN.DISTANCE SIN BETWEEN MODEL STYLE TEMPERATURE COVERAGES • PRESSURE FLOW• SPRINKLERS 155°F(68°C) Feet(Meters) P.S.I.(bars) G.P.M.(L/min.) Feet(Meters) X 12(3.7)x 12(3.7) 7.0(.48) 13(49) "THE INCH"ONE INCH X 14(4.3)x 14(4.3) 7.0(.48) 13(49) GL4906 ADJUSTABLE X — lir 16(4.9)x 16(4.9) 7.0(.48) 13(49) °,— 9(2.7) CONCEALED PENDENT X 18(5.5)x 18(5.5) 12.0(.83) 17(64) X 20(6.1)x20(6.1) 16.7(1.15) 20(76) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. *WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS,A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. **REFER TO PAGE 2 OF GLOBE'S RESIDENTIAL SPRINKLER INSTALLATION GUIDE(BULLETIN R.S.I.G.)FOR NFPA 13D AND 13R REQUIREMENTS. "FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED,USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIAARE STATED. CROSS SECTION • - FLAT COVER WHITE 135°F(57°C) CHROME 135°F(57°C) 2 3/4"DM.MIN. PLATE SIZE PART# PART# HOLE IN CEILING 2 3/8"DIA. 3 5/16"DIA. 332892 332891 L 1 r • r�x I/z" I\ / REDUCER 1 ORDERING INFORMATION I_ SPECIFY CUP 1 4� °1 • Quantity•Model Number•Style Orifice••Temperature••Finishes desired ,i ii DEFLECTOR • Quantity-Wrenches-P/N 332765 DROP PINlit 2 3/4"MAX. Ill I /8"MIN. • • Quantity-Protective Caps-P/N 332868 SUPPORT SHELL-\ ZIA IAI 1 GLOBE®PRODUCT WARRANTY • Globe agrees to repair or replace any of its own manufactured CEILING 3 5/i6"DIA. .1 products found to be defective in material or workmanship for a CEILING COVER PLATE 1/8�� period of one year from date of shipment. 1"ADJUSTMENT FLAT PLATE For specific details.of our warranty please refer to Price List CONCEALED PENDENT Terms and Conditions of Sale(Our Price List). • �• 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 ( 1 z� - I • 989-846-4583 FAX 989-846-9231 FIRE SPRINKLERCoaPORA7ION 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. DEC 2016 GFS-360(Formerly A-10) ADVANCED FIRE PROTECTION, INC. P. O. BOX 1543 WASHINGTON STATE WOODINVILLE,WA 98072 CERTIFICATE OF COMPETENCY I PI-ft FIRE FROTECTiON SPRINKLER SYSTEMS D �'' Michael BalsIe ` ,' HYDRAULIC CALCULATIONS FOR Y t. l' Nelson/Dowd Residence 2437-09 1-CG LEVEL 3 2 2018 Advanc ire P to tion, Inc. i; FEB0) , ADVAN 6 2�Q-1,�, �__.. 4603 Anaco Beach Road CITY OF ANACORE E N SWiti m_.. as,. 1213i 06 Anacortes, WA. 98221 >r a DRAWING NUMBER: WC5088 DATE: Revised 2-8-18 -DESIGN DATA- REMOTE AREA NUMBER: 1 REMOTE AREA LOCATION: Upper Floor Hallway OCCUPANCY CLASSIFICATION: Redidential NFPA 13D DENSITY: . 05 gpm/sq. ft. AREA OF APPLICATION: 2 Heads sq. ft. COVERAGE PER SPRINKLER: 256 sq. ft. TYPE OF SPRINKLERS CALCULATED: Globe GL4906 NUMBER OF SPRINKLERS CALCULATED: 2 TOTAL WATER REQUIRED (INCLUDING HOSE) : 27 . 2 gpm FLOW AND PRESSURE (SRC) :27 .2 gpm @ 34 psi TYPE OF SYSTEM: Wet *DETAILS: WATER SUPPLY Source: TANK Static: 60 psi Residual: 43 psi Flow: 30 gpm • Source Elevation Relative to Finished Flow Level: 0 ft. INSTALLING CONTRACTOR • Name: Advanced Fire Protection • Address : P.O. Box 1543 Woodinville, WA. 98072 Phone: 425-483-5657 Certification number: ADVANFP199B6 NAME OF DESIGNER: Michael Balsley AUTHORITY HAVING JURISDICTION: City of Anacortes NOTES: Calculations performed by HASS under license # 49040769 , granted by HRS SYSTEMS, INC. (Notes continue after pipe calculations results. ) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/8/2018 C: \PROGRAM FILES\HRS SYSTEMS\HASS87\NELSON. SDF JOB TITLE: Nelson/Dowd Residence WATER SUPPLY ANALYSIS Static: 60. 00 psi Resid: 43 . 00 psi Flow: 30. 0 gpm 80 . 0 70 . 0 _ LEGEND 1 0 Available pressure 60 . 0 _ 45 . 85 psi @ 27 . 2 gpm G A 2 m Required pressure U 33. 98 psi @ 27 . 2 gpm 50 . 0 1 A. Source Supply Curve P 40 . 0 B. System Demand Curve R E 2 S � I 30 . 0 S U R E 20 . 0 p 10 . 0B s i 0 . 0 — — - -�— - - — —....— - - — -14 . 7 I I 1 1 1 1 1 1 20 30 40 50 60 70 80 90 100 FLOW (GPM) ote: (1) Dashed Lines indicate extrapolated values from Test Results 1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/8/2018 C: \PROGRAM FILES\HRS SYSTEMS\HASS87\NELSON. SDF JOB TITLE: Nelson/Dowd Residence NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS . PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 60 . 0 43. 0 30 . 0 45 . 9 27 .2 34 . 0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 27 . 2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0 . 0 GPM. OTHER HOSE STREAM ALLOWANCES 0. 0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 27 . 2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) SRC 0. 0 SOURCE 34 . 0 27 . 2 TOR 6. 0 - - - - 29. 8 - - - W1 22 . 0 - - - - 13. 1 - - - W2 23. 0 - - - - 9. 2 - -Si - 24 . 0 K= 4 . 90 8. 3 14 . 1 S2 24 . 0 K= 4 . 90 7 . 0 13 . 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/8/2018 C: \PROGRAM FILES\HRS SYSTEMS\HASS87\NELSON. SDF JOB TITLE: Nelson/Dowd Residence • NFPA3 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) To Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Frm Node El (ft) PT Tot. (Q) Disch Act ID (ft. ) T Pf/ft. (Pf) Pipe: 1 0. 0 0. 0 8 . 00 120 29. 8 TOR 6. 0 29. 8 27 .2 W1 A1. 250 4E: 12 . 0 18 . 00 2 . 6 SRC 0 . 0 34. 0 ' 27 . 2 1.380 T: 6. 0 26. 00 0 . 060 1. 6 Pipe: 6 0. 0 0. 0 6E: 15. 0 50. 00 150 13. 1 W1 22 . 0 13. 1 27 . 1 W2 F1. 000 2T: 12 . 0 32 . 10 6. 9 TOR 6 . 0 29. 8 27 . 1 -1. 101 3R: 5. 1 82 . 10 0. 120 9. 8 Pipe: 7 0. 0 13. 0 S2 18 . 00 150 9.2 W2 23 . 0 9. 2 14 . 1 S1 F1. 000 2E: 5 . 0 11. 00 0 . 4 W1 22 . 0 13. 1 27 . 1 1. 101 T: 6. 0 29. 00 0. 120 3 . 5 Pipe: 8 4 . 90 14. 1 Disch 3 . 00 150 8 . 3 S1 24 . 0 8 .3 0. 0 F1. 000 E: 2 . 5 8 . 50 0 . 4 W2 23 . 0 9.2 14 . 1 1. 101 T: 6. 0 11. 50 0. 036 0 . 4 Pipe: 9 4 . 90 13. 0 Disch 23. 00 150 7 . 0 S2 - 24 . 0 7 . 0 0 . 0 F1. 000 8E: 20 . 0 32 . 00 0 . 4 W2 23. 0 9.2 13. 0 1. 101 2T: 12 . 0 55 . 00 0. 031 1 . 7 NOTES (HASS) :. (1) Calculations were performed by the HASS 8 . 7 computer program in accordance with NFPA13 (2017) under license no. 49040769 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0. 027 gpm and a maximum imbalance at any node of 0.134 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 9. 1 ft/sec at pipe 6. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. • (5) Available pressure at source node SRC under full flow conditions is 41. 50 psi with a flow of 31 . 40 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 2/8/2018 C: \PROGRAM FILES\HRS SYSTEMS\HASS87\NELSON. SDF JOB TITLE: Nelson/Dowd Residence (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter. Equivalent Fitting Lengths in Feet (in) E - T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPVly NPTee 1.380 3. 00 6. 00 2 . 00 7 . 00 6. 00 1 . 00 10. 00 10. 00 6. 00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) • F E T R K C G F45 El Tee RunT Kplg ChkVly Gate 1.101 1 . 40 2 . 50 6. 00 1. 70 1. 00 8 . 00 0 . 40