HomeMy WebLinkAboutDOC-2019-Salish Inn Plans -PROJECT TEAM
OWNER
EK TERA ASARA LLC
905 20TH STREET
ANACORTES, WA 98221
PHONE: (360) 770-3701
FAX:
EMAIL: jas.sho37®gmail.com
CONTACTS: KULJIT SHOKER
ARCHITECT
CARLETTI ARCHITECTS, P.S.
116 E FIR ST. SUITE A
MOUNT VERNON. WA. 98273
PHONE: (360) 424-0394
FAX: (360) 424-5726
EMAIL: peterocarlettiarchitects.com
CONTACTS: PETER CARLETTI
CONTRACTOR
FABER CONSTRUCTION
131 E. GROVER STREET
LYNDEN, WA 98264
PHONE: 360-383-8920
FAX:
EMAIL: Dale6faberconstruction.com
CONTACTS: DALE KING
CIVIL ENGINEER/ SURVEYOR
RAVNIK & ASSOCIATES
P.O. BOX 361
BURLINGTON. WA 98233
PHONE: (360) 707-2048
FAX: (360) 707-2216
EMAIL: jravnikoravnik.net
CONTACT: JOHN RAVNIK
STRUCTURAL ENGINEER
BRADLEY ENGINEERING
810 YEW STREET
BELLINGHAM, WA 98229
PHONE: (360) 752-5795
FAX: -
EMAIL: david®bradleyengineeringinc.com
CONTACT: DAVID BRADLEY
MECHANICAL ENGINEER
BERONA ENGINEERS, INC.
4630 200TH STREET SW, SUITE C
LYNNWOOD. WA 98036
PHONE: (425) 744-6033
FAX: -
E-MAIL: mberona®beronaengineers.com
CONTACT: MELCHOR BERONA
SYMBOLS
00f N1,
NORTH ARROW
1 GRID LINE
A
-4.0 BUILDING SECTION
A WALL SECTION
2 DETAIL
A.6.0
PROPERTY CORNER
INTERSECTION
TOP OF SUBFLOOR ELEVATION MARK
EL. 10'-10 1/2'
25.00' (NEW) SPOT ELEVATION
23.72' (EXIST.)
ROOM -NAME
1-01-1 ROOM NAME / NUMBER
ODOOR MARK
OWINDOW MARK
0-
FLOOR MATERIAL
z ADJACENCY
0
U ALIGN ALIGNMENT OF ITEM
REVISION MARK
INTERIOR ELEVATION
MARKS
ABBREVIATIONS
ABV ABOVE
AFF ABOVE FINISH FLOOR
AC TILE ACOUSTICAL TILE
ACP ACOUSTICAL CEILING PANEL
ACT ACTUAL
AL ALUMINUM
ARCH ARCHITECTURAL
A TILE ASPHALT TILE
AVG AVERAGE
B F F BOTTOM FINISH FLOOR
BLKG BLOCKING
BR BRICK
BOS BOTTOM OF STRUCTURE
CPT
CARPET
CLG
CEILING
CEM
CEMENT
CENTER LINE
C TO C
CENTER TO CENTER
CT
CERAMIC TILE
CLO
CLOSET
CW
COLD WATER
COL
COLUMN
CONIC
CONCRETE
CMU
CONCRETE MASONRY UNIT
CONST
CONSTRUCTION
CONT
CONTINUOUS
COORD
COORDINATE
COR
CORRIDOR
CFM
CUBIC FEET PER MINUTE
DTL
DETAIL
DIA
DIAMETER
DIM
DIMENSION
DO
DITTO
DR
DOOR
DN
DOWN
D.S.
DOWNSPOUT
DWG
DRAWING
DF
DRINKING FOUNTAIN
EA
EACH
ELEC
ELECTRICAL
ELEV, EL
ELEVATION
EQ
EQUAL
(E) EXIST
EXISTING
EXT
EXTERIOR
GENERAL NOTES
PROJECT DATA
1.
IN GENERAL, PLAN DIMENSIONS SHOWN ARE TO FACE OF STUD OR
PROPERTY INFORMATION
JNT
JOINT
FACE OF CONCRETE. UNLESS OTHERWISE NOTED. DO NOT SCALE THESE
DRAWINGS, USE CALCULATED DIMENSIONS ONLY. VERIFY ALL DIMENSIONS
PROPERTY ADDRESS 907 30TH STREET
LVL
LEVEL
DATUM, AND LEVELS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT
ANACORETES, WA 98221
L
LONG, LINE
IMMEDIATELY OF ANY DISCREPENCIES.
BUILDING CODE 2015 IBC/ 2012 IFC
LAV
LAVATORY
2.
CONTRACTOR SHALL VERIFY ALL EXISTING CO0
ENERGY CODE 2018 WASHINGTON STATE NREC
LIN
LINOLEUM
INITIATING THE WORK. NOTIFY ARCHITECT OF ANY DISCREPANC S.
LT
LIGHT
3.
ALL WORK SHALL COMPLY WITH THE 2015 IB IFC. IPC. IMC AS AM NDED BY WASH.
FIRE SPRINKLERS YES
STATE. PROJECT SHALL ALSO COMPLY WITH HE 2018 NREC AND TH VIACQ CODES.
MAR
MARBLE
PROJECT SHALL ALSO COMPLY W/ JURISDICT NAL CODE AMENDME TS BY THE LOCAL
FIRE ALARM YES
MO
MASONRY OPENING
AGENCY. CONTRACTOR IS RESPONSIBLE FOR OB INING NECESSA PERMITS &
ZONING
MFR
MANUFACTURE
INSPECTIONS TO COMPLETE THE WORK. CONTRAC A URRENT VALID CITY
OR COUNTY BUSINESS LICENSE PRIOR TO ISSUANCE OF PERMIT. WHEN REQUIRED BY LAW.
ZONING: C- COMMERCIAL
MATL
MATERIAL
MAX
MAXIMUM
4.
ERRORS, OMISSIONS. AND DISCREPANCIES. IF ANY, SHALL BE REFERRED
SITE SF/ ACRES:.35 ACRES
MECH
MECHANICAL
TO THE ARCHITECT IMMEDIATELY FOR DIRECTION OF HOW TO PROCEED.
..µµ
PARCEL
MTL
METAL
5.
VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THE CONTRACT BY
PARCEL: P60611 AND P60612
MIN
MINIMUM
OTHERS PROVIDE ALL BLOCK -OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR
MUL
MULLION
DUCTS, PIPES, CONDUITS, EQUIPMENT. FIXTURES, AND CABINETS. VERIFY SIZE AND
TW N . / R N G. / SEC.
LOCATION.
TWN35 RNG02 SEC30
NAT
NATURAL
6.
DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN. EXCEPT
BUILDING SETBACKS
NOM
NOMINAL
UPON WRITTEN INSTRUCTIONS OF THE ARCHITECT.
NA
NOT APPLICABLE
7.
VERIFY LOCATION OF ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO:
FRONT STREET (NORTH): 0'-0' REQUIRED (OK)
NIC
NOT IN THIS CONTRACT
SEWER, SEPTIC, WATER, GAS, POWER, AND TELEPHONE. CAP, MARK AND PROTECT.
SIDE: INTERIOR (EAST): 0'-0' REQUIRED (OK)
NTS
NOT TO SCALE
8.
DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR MODIFICATION
SIDE: INTERIOR (WEST): 0'-0' REQUIRED (OK)
NO, #
NUMBER
MAY BE REQUIRED TO SUIT THE FIELD DIMENSIONS OR CONDITIONS AND SUCH
REAR: (SOUTH): 0'-0' REQUIRED (OK)
MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK OF THE CONTRACT.
BUILDING HEIGHT
OC
ON CENTER
9.
PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF ALL GOVERNING
OD
OUTSIDE DIMENSION
AUTHORITIES. AT RATED PARTITIONS. FLOORS, CEILINGS. AND ROOF
40'-0' MAX ALLOWED PER ZONING
0/
OVER
LOCATIONS. ALL REQUIRED FIRE -RATED PARTITIONS SHALL BE
(42'-0' MAX ALLOWED FROM AVERAGE EXISTING GRADE)
OVHD
OVERHEAD
CONTINUOUS FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE.
PARKING CALCULATION
10.
THE CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES, INCLUDING
PNT
PAINT
DESIGN -BUILD DOCUMENTS REQUIRED BY CONTRACT DOCUMENTS, TO VERIFY
-PARKING REQ'D MOTEL
PTD
PAINTED
SIZE. WEIGHT, POWER, LOCATION AND OTHER REQUIREMENTS AND LOCATION
1 STALLS REQUIRED PER UNIT
PL
PLASTER. PLATE
OF THOSE ITEMS TO BE INSTALLED PRIOR TO COMMENCEMENT OF WORK.
36 UNITS 36 STALLS PROVIDED
P LAM
PLASTIC LAMINATE
11.
NO BUILDING OR PORTION OF A BUILDING SHALL BE OCCUPIED OR USED
-(2) ACCESSIBE ADA STALLS PROVIDED 1 BEING VAN(OK)
PLYWD
PLYWOOD
FOR STORAGE PRIOR TO THE ISSUANCE OF THE CERTIFICATE
OF OCCUPANCY. NO EXCEPTIONS.
BUILDING CODE DATA
PT
POST -TENSIONED CONCRETE
12. SEPERATE PERMITS ARE REQUIRED FOR PLUMBING, MECH.. ELEC.. FIRE SPRINKLER,
PRESSURE -TREATED WOOD OCCUPANCY IR-11 -RESIDENTIAL -HOTEL
QT
QUARRY TILE
RL
RAIN LEADER
REF
REFRIGERATOR.
REFERENCE
REINF
REINFORCING BAR
REV
REVISION
R
RISER, RADIUS
RM. RMS
ROOM. ROOMS
RO
ROUGH OPENING
SCHED
SCHEDULE
SEC
SECTION
PO
FACE OF, FINISH OPENING
SHT
SHEET
FRP
FIBERGLASS REINF POLYESTER
SV
SHEET VINYL
FIN
FINISH
Sc
SOLID CORE
FAAP
FIRE ALARM ANNUNCIATOR
SPECS
SPECIFICATIONS
PANEL
SF
SQUARE FEET
FD
FIRE DAMPER
S & V
STAIN & VARNISH
FE
FIRE EXTINGUISHER
SV
SHEET VINYL
FF
FACTORY FINISH
STRWY
STAIRWAY
FF
FINISH FLOOR
STL
STEEL
FRT
FIRE RETARDANT TREATED
STOR
STORAGE
FLASH
FLASHING
STRUCT
STRUCTURAL
FLR
FLOOR
SUSP
SUSPENDED
F.A.
FLUID -APPLIED
THRESH
THRESHOLD
FND
FOUNDATION
T.O.
TOP OF
FOIC
FURNISHED BY OWNER,
T
TREAD, THICKNESS
INSTALLED BY CONTRACTOR
TEMPERED
FOIO
FURNISHED BY OWNER,
TS
TUBE STEEL
INSTALLED BY OWNER
TYP
TYPICAL
FCIC
FURNISHED BY CONTRACTOR.
UNPIN
UNFINISHED
INSTALLED BY CONTRACTOR
UNO
UNLESS NOTED OTHERWISE
UR
URINAL
GA
GAUGE
GALV
GALVANIZED
VCT
VINYL COMPOSITION TILE
GAP
GENERATOR ALARM PANEL
VERT
VERTICAL
GL
GLASS
VIN
VINYL
GWB
GYPSUM WALLBOARD
VR
VAPOR RETARDER
VTO
VENT TO OUTSIDE
HC
HANDICAP
WC
WATER CLOSET
HDWE
HARDWARE
WP
WATERPROOFING
HP
HEAT PUMP
WS
WHEEL STOP
HT
HEIGHT
W
WIDTH
HM
HOLLOW METAL
WDO
WINDOW
HOR
HORIZONTAL
W/
WITH
HB
HOSE BIB
WD
WOOD
HW
HOT WATER
WI
WROUGHT IRON
HWT
HOT WATER TANK
WRGB
WATER RESISTANT
HMD
HOLLOW METAL DOOR
GYPSUM BOARD
HMF
HOLLOW METAL FRAME
ZINC.
ZINCALUME
ID
INSIDE DIMENSION
INSUL
INSULATION
INT
INTERIOR
VICINITY MAP
FIRE ALARM SYSTEMS & SIGNAGE.
13. ALL EXPOSED EXTERIOR SHEET METAL SHALL BE GALVANIZED, PRIMED AND PAINTED. (B) - ACESSORY USES TO HOTEL- OFFICE- FRONT DESK, BREAKFAST ROOM
14. ALL WOOD IN CONTACT W/ CONCRETE SHALL BE PRESSURE TREATED. CONSTRUCTION TYPE V-A FULLY SPRINKLED.
PRESSURE TREATED WOOD SHALL BE USED FOR WOOD MEMBERS WHICH R-1 ALLOWABLE (4I STORY 36.000 S.F AND 70'-0' TALL.
FORM THE STRUCTURAL SUPPORT OF BALCONIES. DECKS, OR PORCHES
ETC. WHEN SUCH MEMBERS ARE EXPOSED TO THE WEATHER. FIRST FLOOR
15. SLOPE ALL DECKS. PATIOS, AND WALKWAYS AWAY FROM BUILDING SECOND FLOOR
MINIMUM OF 1/8'/FT FOR POSITIVE DRAINAGE. THIRD FLOOR
FOURTH FLOOR
16. PROVIDE EXPANSION JOINTS IN ALL CONCRETE SLABS AS REQUIRED
TO PREVENT CRACKING, SAW CUT ALL SLABS AS REQ'D. TOTAL SF
17. PROVIDE FIREBLOCKING, DRAFTSTOPS, AND FIRESTOPS IN ATTICS, FLOORS,
AND WALL CAVITIES AS REQUIRED PER THE IBC. FIRE FLOW
18. ROOF DRAINS, AND OVERFLOW DRAINS SHALL COMPLY W/ THE IPC & IBC.
AND WALL CAVITIES AS REQUIRED PER THE IBC. V-A 17,812 FIRE FLOW 2,750
REDUCE BY 75% FOR SPINKLERS - 1,500 REQURIED (OK)
3.358 S.F. COVERED PARKING/CANOPY 1,410 S.F.
4.818 S.F.
4.818 S.F.
4.818 S.F.
17,812 S.F. NO STORY EXCEEDS 36,000 S.F.
W.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF
SIMILAR CHARACTER TO DETAILS SHOWN. SIMILAR DETAILS OF
DEFERRED SUBMITTALS
CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ARCHITECT.
20.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE MEANS,
-ELECTRICAL PERMIT/ DRAWINGS
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK.
-FIRE PROTECTIONS SYSTEM - FIRE SPRINKLERS
-FIRE PROTECTIONS SYSTEM - FIRE ALARM & DETECTION SYSTEM
21.
CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL
-SIGNAGE PERMITS
CHANGES DURING CONSTRUCTION. THE SET SHALL BE A PART OF THE CONTRACTOR'S
-LIGHTING PLAN AND NREC
CLOSE-OUT PACKAGE TO THE OWNER. CLOSE-OUT PACKAGE SHALL INCLUDE:
(1) SET OF SHOP DRAWINGS, PRODUCT LITERATURE. EQUIPMENT WARRANTEE MANUALS.
SPECIAL INSPECTIONS REQUIRED
22.
CONTACTOR SHALL PROVIDE SOLID BLOCKING, UNLESS NOTED OTHERWISE AS REQUIRED
PER IBC CHAPTER 17 PROVIDE THE FOLLOWING
FOR NAILING OF ALL INTERIOR AND EXTERIOR TRIMS, FINISHES. AND FIXTURES. THE
SPECIAL INSPECTIONS:
CONTRACTOR SHALL PROVIDE FOR ALL THE NECESSARY FRAMING AND BRACING FOR THE
EARTHWORK AND COMPACTION
INSTALLATION OF OWNER FURNISHED ITEMS SUCH AS SIGNAGE. MENU BOARDS ETC.
STEEL CONSTRUCTION AND HIGH STRENGTH BOLTING
EPDXY AND DOWLED ANCHORS AND REBAR
23.
WHERE EXISTING WORK IS DAMAGED, CUT, OR DEFACED DUE TO PERFORMANCE
STEEL REINFORCEMENT
OF NEW WORK. THE CONTRACTOR SHALL PATCH AND REPAIR SAME TO MATCH ADJOINING
CONCRETE
SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL
STRUCTURAL OBSERVATION
BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE OR SIMILAR.
SEE STRUCTURAL DRAWINGS FOR ADDITIONAL NOTES
24. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT
AND MAY BE REPRODUCED ONLY WITH THE WRITTEN PERMISSION OF THE
ARCHITECT. AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME OF
THE ARCHITECT.
SPECIAL USE SECTION 420
420.2 -SEPARATING WALLS -WALLS SEPARATING
ENERGY
CODE
DWELLING UNITS IN THE SAME BUILDING SHALL BE
BUILDING ENVELOPE
CONSTRUCTED AS FIRE PARTITIONS PER IBC 708
420.3 - HORIZONTAL SEPARATION - WALLS SEPARATING
1. SLAB INSULATION, IF ANY SHALL CONFORM TO THE SPECIFICATIONS
DWELLING UNITS IN THE SAME BUILDING SHALL BE
AND, IF EXPOSED, SHALL BE PROTECTED AGAINST DAMAGE FROM ALL
CONSTRUCTED AS HORIZONTAL ASSEMBLIES IN
SOURCES.
ACCORDANCE WITH SECTION 711. (NOT REQUIRED
2. ALL INSULATION SHALL BE OF THE THICKNESS AND DENSITY AS
BECAUSE THERE IS NOT HORIZONTAL SEPARATION
PRESCRIBED IN THE PLANS. INSULATION SHALL BE INSTALLED
BETWEEN DWELLING UNITS.)
ACCORDING TO THE MANUFACTURERS' RECOMMENDATIONS.
3. DOORS AND GLAZING SHALL BE OF THE TYPE AND SIZE OF THOSE
420.5 - AUTOMATIC SPRINKLER SYSTEM. GROUP R
PRESCRIBED IN THE PLAN. U-VALUES SHALL MEET OR BE LESS THAN
OCCUPANCIES SHALL BE EQUIPPED THROUGHOUT WITH
THOSE SHOWN ON THE PLAN.
AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
4. AIR LEAKAGE IS CONTROLLED BY SEALING OR CAULKING ALL JOINTS
WITH SECTION 903.2.8 (OK) PROVIDING FIRE SPRINKLER
AND GAPS IN FRAMING. SEALANTS SHALL BE OF THE NON -HARDENING
SYSTEM
5. WALL, CEILING AND SLAB INSULATION SHALL BE AS CALLED
RATED ASSEMBLIES
OUT ON THE APPROVED PLANS AND SHALL CONFORM TO STANDARDS
REGARDING DENSITIES AND R-VALUES. AN APPROPRIATE MOISTURE
TABLE 601 RATING REQ'D FOR BUILDING ELEMENTS
BARRIER SHALL BE INSTALLED ON THE WARM SIDE OF THE EXPOSED
WALLS. IT SHALL BE CONTINUOUS AND SEALED.
BUILDING ELEMENT
TYPE V-A
6. FRAMING ASSEMBLIES SHALL BE SHOWN ON THE APPROVED PLANS
PRIMARY STRUCTURAL FRAME
1-HOUR
BEARING WALLS EXTERIOR
INTERIOR
1-HOUR
NON -BEARING WALLS AND
PARTITIONS
0-HOUR
FLOOR ASSEMBLY
1-HOUR
ROOF CONSTRUCTION
1-HOUR
ALL BEARING WALLS 1-HOUR RATED SEE FILE # GA
3661
-ALL STAIR/ ELEVATOR/ SHAFT WALLS 2-HOUR RATED
SEE FILE # GA WP 4230
-1/2 HOUR FIRE PARTITION BETWEEN UNITS SEE GA
FILE # GA 3380
-ALL FLOOR ASSEMBLIES 1-HOUR RATED SEE FILE
# PC 5012
-ALL ROOF ASSEBLIES 1-HOUR RATED SEE FILE
# RC 2603
708 FIRE PARTITIONS
708.1 GENERAL - R-1 SHALL COMPLY WITH THIS
SECTION.
708.3 FIRE RESISTANCE RATING - FIRE PARTITIONS
SHALL HAVE A FIRE RESISTANCE RATING OF NOT LESS
THAN 1 HOUR:
EXCEPTION 2: DWELLING UNIT AND SLEEPING UNIT IN
BUILDINGS OF TYPE V-B CONSTRUCTION SHALL HAVE
FIRE RESISTANCE RATING OF NOT LESS THAN 1/2 HOUR
IN BUILDINGS EQUIPPED THROUGHOUT WITH AND
AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
SECTION 903.3.1.1
708.4 CONTINUITY - FIRE PARTITIONS SHALL
EXTEND FROM THE TOP OF THE FOUNDATION OR
FLOOR/ CEILING ASSEMBLY BELOW TO THE UNDERSIDE
OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK
ABOVE OR TO THE FIRE -RESISTANCE - RATED FLOOR/
CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND
SHALL BE SECURELY ATTACHED HERETO. (1/2) HOUR
RATED WALLS BETWEEN DWELLING UNITS EXTEND FROM
FOUNDATION TO THE UNDERSIDE OF THE FLOOR AND
ROOF SHEATHING ABOVE (OK)
SECTION 713.4 FIRE RESISTANCE RATING. SHAFT
ENCLOSURES SHALL HAVE A FIRE RESISTANCE RATING OF
NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR
STORIES OR MORE. AND NOT LESS THAN 1 HOUR WHERE
CONNECTION LESS THAN FOUR STORIES.
SECTION 711 HORIZONTAL ASSEMBLIES:
SECTION 711.2.4.3 DWELLING UNITS AND SLEEPING UNITS.
HORIZONTAL ASSEMBLIES SERVING AS DWELLING OR
SLEEPING UNIT SEPARATIONS IN ACCORDANCE WITH
SECTION 420.3 SHALL BE NOT LESS THAN 1-HOUR
FIRE -RESISTANCE RATED CONSTRUCTION
RATED WALLS - IDENTIFICATION
IBC 703.7 MARKING AND IDENTIFICATION FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS,
SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE
PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY
IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL:
1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR -CEILING OR ATTIC SPACES;
2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT
EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION; AND
3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8' STROKE
IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING. 'FIRE AND/OR SMOKE
BARRIER - PROTECT ALL OPENINGS' OR OTHER WORDING.
DRAWING INDEX
A-0.0 COVER SHEET/ CODE ANALYSIS
A-0.1 OCC. LOAD/ GA ASSEMBLIES
CIVIL
SHEET 1 OF 17 COVERSHEET
SHEET 2 OF 17 EROSION CONTROL PLAN 1 OF 2
SHEET 3 OF 17 EROSION CONTROL PLAN 2 OF 2
SHEET 4 OF 17 ONSITE PLAN
SHEET 5 OF 17 OFFSITE SITE PLAN 1 OF 2
SHEET 6 OF 17 OFFSITE SITE PLAN 2 OF 2
SHEET 7 OF 17 30TH ST PLAN & PROFILE 1
SHEET 8 OF 17 30TH ST PLAN & PROFILE 1
SHEET 9 OF 17 'Q' AVE PLAN & PROFILE
SHEET 10 OF 17 DIMS, PARKING .SIGNAGE
SHEET 11 OF 17 BUILDING SETBACK AND CROSS -SECTIONS
SHEET 12 OF 17 DETAILS
SHEET 13 OF 17 DETAILS
SHEET 14 OF 17 DETAILS
SHEET 15 OF 17 SPECIFICATIONS
SHEET 16 OF 17 SPECIFICATIONS
SHEET 17 OF 17 SPECIFICATIONS
ARCHITECTURAL
A-1.0 SITE PLAN
A-2.0 FIRST FLOOR PLAN
A-2.1 SECOND FLOOR PLAN
A-2.2 THIRD FLOOR PLAN
A-2.3 FOURTH FLOOR PLAN
A-2.4 ROOF PLAN
A-2.5 SCHEDULES
A-2.6 SCHEDULES
A-2.7 FIRST FLOOR REFLECTED CLG PLAN
A-2.8 SECOND FLOOR REFLECTED CLG PLAN
A-2.9 THIRD FLOOR REFLECTED CLG PLAN
A-2.10 FOURTH FLOOR REFLECTED CLG PLAN
A-3.0 ELEVATIONS
A-4.0 SECTIONS
A-4.1 SECTIONS
A-4.2 SECTIONS
A-4.3 SECTIONS
A-4.4 SECTIONS
A-4.5 SECTIONS
A-5.0 TYP. WALL SECTIONS
A-5.1 TYP. WALL SECTIONS
A-5.2 TYP. WALL SECTIONS
A-6.0 STAIR DETAILS
A-6.1 WALL TYPES
A-6.2 DOOR/ WDO DETAILS
A-6.3 SIDING DETAILS
A-6.4 ROOF DETAILS
STRUCTURAL
S-1 of 10 FOUNDATION PLAN
S-2 of 10 DETAILS
S-3 of 10 SECOND FLOOR FRAMING
S-4 of 10 THIRD FLOOR FRAMING
S-5 of 10 FOURTH FLOOR FRAMING
S-6 of 10 ROOF FRAMING
S-7 of 10 MAIN FLOOR SHEAR WALLS
S-8 of 10 SECOND - FOURTH FLOOR SHEAR WALLS
9-9 of 10 ELEVATION HOLD DOWNS
S-10 of 10 NOTES SPECS
MECHANICAL
M-0.0 LEGEND & NOTES
M-0.1 HVAC SCHEDULES
M-2.1 FIRST FLOOR HVAC PLAN
M-2.2 SECOND FLOOR HVAC PLAN
M-2.3 THIRD FLOOR HVAC PLAN
M-2.4 FOURTH FLOOR HVAC PLAN
M-2.5 HVAC ROOF PLAN
M-3.0 HVAC DETAILS
P-0.0 LEGEND & NOTES
P-0.1 PLUMBING SCHEDULES
P-2.0 FOUNDATION PLUMBING PLAN
P-2.1 FIRST PLUMBING PLAN
P-2.2 SECOND PLUMBING PLAN
P-2.3 THIRD PLUMBING PLAN
P-2.4 FOURTH PLUMBING PLAN
P-3.1 FIRST FLOOR DOMESTIC WATER PLAN
P-3.2 SECOND FLOOR DOMESTIC WATER PLAN
P-3.3 THIRD FLOOR DOMESTIC WATER PLAN
P-3.4 FOURTH FLOOR DOMESTIC WATER PLAN
P-4.0 PLUMBING WASTE & VENT RISERS
P-4.1 PLUMBING DETAILS
LANDSCAPE
L-1 PLANTING PLAN
VELOPE REQUIREMENTS PER 2012 IF -CC. WSEC AMENDMENTS
THE FOLLOWING ARE REFERENCES DIRECTLY FROM CHAPTER 51-11C WAC
FOR ENVELOPE REQUIREMENTS. CONTRACTOR TO VERIFY ALL SUB TRADES
RECOGNIZE ALL REQUIREMENTS TO ACHIEVE ENVELOPE LEAKAGE
MINIMUMS AS REGULATED BY STATE CODE.
C402.4.1.2.3 BUILDING TEST.
THE COMPLETED BUILDING SHALL BE TESTED AND THE AIR LEAKAGE
RATE OF
THE BUILDING ENVELOPE SHALL NOT EXCEED 0.40 CFM/FT2 AT A
PRESSURE DIFFERENTIAL OF 0.3 INCHES WATER GAUGE IN
ACCORDANCE WITH ASTM E 779 OR AN EQUIVALENT METHOD APPROVED
BY THE CODE OFFICIAL. A REPORT THAT INCLUDES THE TESTED
SURFACE AREA, FLOOR AREA, AIR BY VOLUME, STORIES ABOVE GRADE,
AND LEAKAGE RATES SHALL BE SUBMITTED TO THE BUILDING OWNER
AND THE CODE OFFICIAL.
C402.4.2 AIR BARRIER PENETRATIONS.
PENETRATIONS OF THE AIR BARRIER AND PATHS OF AIR LEAKAGE
SHALL BE CAULKED, GASKETED OR OTHERWISE SEALED IN A MANNER
COMPATIBLE WITH THE CONSTRUCTION MATERIALS AND LOCATION.
JOINTS AND SEALS SHALL BE SEALED IN THE SAME MANNER OR
TAPED OR COVERED WITH A MOISTURE VAPOR -PERMEABLE WRAPPING
MATERIAL. SEALING MATERIALS SHALL BE APPROPRIATE TO THE
CONSTRUCTION MATERIALS BEING SEALED. THE JOINTS AND SEALS
SHALL BE SECURELY INSTALLED IN OR ON THE JOINT FOR ITS ENTIRE
LENGTH SO AS NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR ITS
ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND,
STACK EFFECT AND MECHANICAL VENTILATION.
C402.4.3 AIR LEAKAGE OF FENESTRATION.
THE AIR LEAKAGE OF FENESTRATION ASSEMBLIES SHALL MEET THE
PROVISIONS OF TABLE C402.4.3. TESTING SHALL BE IN ACCORDANCE
WITH THE APPLICABLE REFERENCE TEST STANDARD IN TABLE C402.4.3
BY AN ACCREDITED, INDEPENDENT TESTING LABORATORY AND LABELED
BY THE MANUFACTURER.
C402.4.5.2 OUTDOOR AIR INTAKES AND EXHAUSTS.
OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS SHALL
BE PROVIDED WITH CLASS IA MOTORIZED DAMPERS WHICH CLOSE
AUTOMATICALLY WHEN THE SYSTEM IS OFF. RETURN AIR DAMPERS
SHALL BE EQUIPPED WITH MOTORIZED DAMPERS. DAMPERS SHALL HAVE
A MAXIMUM LEAKAGE RATE OF 4 CFM/FT2 AT 1.0 INCH WATER GAUGE
(W.G.) (249 PA) WHEN TESTED IN ACCORDANCE WITH AMCA 500D.
BLDG OFFICAIL TO CHOOSE 12 UNITS TO DO BLOWER DORR TEST
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0` 424-0394
Fax: 424-5726
6429
EG STERED
'--, A HITECT
STATE ORIWASHINGTON
6-14-19
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
rABER
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE
COVERSHEET
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A - n�j I
n�j
0
COPYRIGHT 2019 CARLETTI ARCHITECTS, P.S.
PLUMBING CALCULATIONS
EACH HOTEL UNIT HAS 1 RESTROOM, 1 LAV., 1 SHOWER. 3 UNITS ARE ADA ACCESSIBLE. TWO RESTROOMS
PROIVED ON FIRST FLOOR FOR GUEST AND STAFF.
7'-6'
eS;O 60 6' CLEAR
FLOC SPACE
o INK IN
d P-LAM
" o OUNTER
1'-6''� 2'-6' LINE OF
36' MIN. 30' X 48' CLEAR
5'-0' FLOOR SPACE
&RLN.-PLAN
_z -
N
ELEVATION
ELEVATION
GWB, PAINT
24 X 48 MIRROR
SOAP DISP.
19
�-6.0
60' P-LAM o
COVED SV
BASE
^SEEN GWB. PAINT
X 48 MIRROR
PER TOWEL
WENSER
' P-LAM
AT COVER DISP.
12' GRAB BAR
BASE
ELEVATION
GENERIC NOTES FOR W.C. COMPARTMENTS
PER ANSI A117.1 CHAPTER 6
1. MIN. SIZE OF STALL 60' WIDE PERP. TO SIDEWALL
56' DEEP FOR WALL HUNG W.C. & 59' DEEP FOR FLR. MTD.
2. PROVIDE TOE CLEARANCES 0 FRONT PORTION AND MIN. (1)
SIDE 9' A.F.F. HIGH EXTENDING MIN. 6' BEYOND PARTITION.
TOE CLEARANCE SHALL BE PERMITTED TO EXTEND MAX. 25' UNDER AN ELEMENT.
TOE CLEARANCE SHALL EXTEND 17' MIN. BENEATH ELEMENT WHEN T.C. IS REQ'D.
AS PART OF A CLEAR FLOOR SPACE.
TOE CLEARANCE SHALL BE A MIN. OF 30' WIDE.
3. IN MULTIPLE STALL RESTROOMS OF (6) SIX OR MORE PROVIDE MIN. (1) AMBULATORY
STALL W/ MIN. MIN. 36' WIDE BY 60' DEEP COMPARTMENT. INSTALL SIDE -WALL GRAB
BARS EA. SIDE OF COMPARTMENT.
4. STALL DOOR TO BE HINGED MAX. 4' FROM THE ADJACENT WALL OR PARTITION
FARTHEST FROM THE W.C.
5. STALL DOOR SHALL BE SELF -CLOSING. DOOR PULL SHALL BE PLACED ON
EA. SIDE OF STALL DOOR. MNT. PULL MIN. 34' MAX. 48' A.F.F. PULL SHALL NOT
REQUIRE TIGHT GRASPING. PINCHING. OR TWISTING OF THE WRIST TO OPERATE.
6. PROVIDE MIN. 42' CLEAR IN FRONT OF STALL DOOR.
7. PROVIDE COAT HOOKS WITHIN TOILET COMPARTMENT MAX. 48' A.F.F.
GENERIC NOTES FOR ONE W.C. TOILET RM.
PER ANSI A117.1 CHAPTER 6
1. UNLESS NOTED OTHERWISE ALL DIMENSIONS SHOWN ARE MINIMUM.
2. OVER AND UNDER DIMENSIONS INDICATE ACCEPTABLE LIMITS.
3. DIMENSIONS SHOWN ARE ACCEPTABLE MINIMUM. AND MAY BE
USED IN CONJUNCTION WITH OTHERS AS SHOWN.
4. EXPOSED DRAIN PIPES AND HOT WATER PIPES SHALL BE RECESSED.
INSULATED OR GUARDED TO PREVENT BURN ACCIDENTS.
5. GRAB BARS SHALL BE 1 1/4' TO 1 1/2' OUTSIDE DIA. AND SHALL BE
ABLE TO SUPPORT A 300 LB LIVE LOAD WITHOUT PERMANENT DEFLECTION.
6. PLUMBING FIXTURES AND ACCESSORIES ARE FOR ILLUSTRATIVE PURPOSES
ONLY. REFER TO ACTUAL PLANS. INTERIOR ELEVATIONS. SPECIFICATIONS. ECT.
FOR SPECIFIC FIXTURES AND ACCESSORIES FOR THIS PROJECT.
7. ALL HANDICAPPED TOILET ROOMS FIXTURES AND ACCESSORIES SHALL
COMPLY W/ CHAPTER 11 OF THE IBC. ANSI A117.ADA. AND WAC 51-50.
8. ADDITIONAL FIXTURES SHALL BE MOUNTED AS FOLLOWS:
T.P. DISP. 7-9' MAX. IN FRONT OF W.C. AND BTWN. 15' & 48' A.F.F.
ALLOW MIN. 1-1/2' BETWEEN G.B. AND DISP. MNT. SOAP DISPENSER
MAX. 40' A.F.F. BTM. EDGE OF MIRROR MAX. 40' A.F.F.
9. PROVIDE ADA SIGNAGE PER IBC 2006 AND ANSI A117.
10. SEE ACTUAL TOILET ROOM PLANS FOR ACTUAL DIMENSIONS AND LAYOUT.
11. PROVIDE OPEN ENDED TOILET SEATS PER IPC 409.2.3.
12. T.O. W.C. SEAT MIN.17' /MAX.19' A.F.F. SEAT SHALL NOT RETURN AUTOMATICALLY.
13. FLUSH CONTROLS HAND OPERATED OR AUTOMATIC.
14. MAX. DEPTH OF LAV. BOWL TO BE 6-1/2' DEEP. HAND OPERATED FAUCETS,
SELF -CLOSING SHALL REMAIN ON FOR MIN. 10 SECONDS.
15. FRONT OF LAV. TO BE MAX. 34' A.F.F. MEASURED TO RIM OF SINK.
18' VERT.
GRAB BAR
GWB. PAINT
1 1/2'
GRAB BAR
60' P-LAM
TISSUE PAPER
DISPENSER
COVED SV BASE
GREEN GWB, PAINT
60' P-LAM
COVED SV BASE
GENERIC NOTES FOR SHOWER STALLS
PER ANSI A117.1 CHAPTER 6
1. MIN. SIZE OF STALL 36' X 36' W/ 36' WIDE BY 48' DEEP CLEAR FLOOR IN FRONT OF STALL.
2. PROVIDE GRAB BARS ACROSS THE CONTROLL WALL AND ON THE BACK WALLTO A POINT 18,
FROM THE CONTROL WALL.
3. PROVIDE SWING UP SEAT WHICH FASTENS TO WALL. SEAT TO SUPPORT MIN. 250# LIVE LOAD.
MNT. SEAT MIN. 17' MAX. 19' A.F.F.
4. MNT. CONTROLS ON THE SIDE WALL OPP THE SEAT 38' MIN. AND 48' MAX. THE SHOWER FLOOR.
5. MAX. THRESHOLD FOR SHOWER LIP TO BE Y'. RECESS STALL INTO CONC. SLAB PER MANF'S.
6. PROVIDE SHOWER SPRAY UNIT W/ HOSE MIN. 59' LONG. CONTROLS FOR HEAD TO Be WITHIN 15,
LEFT OR RIGHT OF THE CENTERLINE OF THE SEAT.
7. GRAB BARS TO BE 1-V DIA. W/ MIN. WV CLEAR BETWEEN G.B. AND WALL.
8. INSTALL LIMIT DEVICE TO PREVENT THERMAL SHOCK PROTECTED TO 120 DEGREES F.
One -Hour Assembly
Assembly F
CAN/ULC-S101 and ASTM E119;
[CC ES report ESR-2994. PFS
Corporation listing directory. See
reports for additional construction
information.
ROOF - �GA FILE NO
1. 48/24 tahgue-and-groove, span -rated sheathing (Exposure 1)
2. 5/e" thick Type C gypsum board
3. Red -I" joist (with flange size minimum of 11/2" thick x 31/2" wide).
Maximum spacing of 24" on -center for floor/ceiling assemblies.
When used in roof/ceiling assembly, spacing is permitted to
exceed 24" on -center.
4. Resilient channel at 16" on -center
5. Minimum 11/2" thick (2.3 pcf minimum) mineral wool Batts
R C 2603
GA FILE NO. WP 4230 I I GENERIC
GYPSUM WALLBOARD, WOOD STUDS,
MINERAL FIBER INSULATION
Base layer 5/s" type X gypsum wallboard applied at right angles to each side of 2 x 6 wood
studs 24" o.c. with 21/4" Type S or W drywall screws 24" o.c. Face layer 5/8" type X
gypsum wallboard applied at right angles to each side with 21/4" Type S drywall screws
8" o.c. 5112" mineral fiber insulation, nominal 3 pcf, friction fit in stud space.
Joints staggered 24" each layer and side.
Tested at 5,506 Ibs per stud or 100 percent of design load. (LOAD -BEARING)
SCALE: N.T.S.
2 HOUR
FIRE
Thickness: 8"
Approx. Weight: 13 psf
Fire Test: ITS J20-06170.3, 12-00
WALL. _ GA FILE NO. WP 4230
GA FILE NO. WP 36" I GENERIC I
GYPSUM WALLBOARD, WOOD STUDS,
MINERAL FIBER INSULATION
One layer 5/s" type X gypsum wallboard applied at right angles to each side of 2 x 4 wood
studs 16" o.c. with 21/4" Type S or W drywall screws 12" o.c. 3112" mineral fiber
insulation, nominal 2.5 pcf, friction fit in stud space.
Vertical joints staggered 16" o.c., horizontal joints staggered 24" o.c., on opposite sides.
Tested at 2,578 Ibs per stud or 100 percent of design load. (LOAD -BEARING)
4� WALL - GA FILE NO.
WALLS AND INTERIOR PARTITIONS, WOOD -FRAMED
GA FILE NO. WP 3380 GENERIC
GYPSUM WALLBOARD, WOOD STUDS
One layer 5/8" type X gypsum wallboard or gypsum veneer base applied parallel or at
right angles to each side of 2 x 4 wood studs 16" o.c. staggered 8" o.c. on 2 x 6 wood
plates with 6d coated nails, 1 7/8" long, 0.0915" shank, 1/4" heads, 7" o.c.
Joints staggered 24" on opposite sides. Horizontal bracing required at mid -height.
(LOAD -BEARING)
WALL - GA FILE NO.
GA FILE NO. WP 3661 GENERIC I
GYPSUM WALLBOARD, WOOD STUDS,
MINERAL FIBER INSULATION
One layer 5/a" type X gypsum wallboard applied at right angles to each side of 2 x 6 wood
studs 16" o.c. with 21/4" Type S or W drywall screws 12" o.c. 51/2" mineral fiber
insulation, nominal 2.5 pcf, friction fit in stud space.
Vertical joints staggered 16" o.c., horizontal joints staggered 24" o.c., on opposite sides.
Tested at 5,156 Ibs per stud or 100 percent of design load. (LOAD -BEARING)
2 \
GA FILE NO.
GA FILE NO. CM 1450 I GENERIC
GYPSUM WALLBOARD, STEEL COLUMN COVER
Base layer 1/2" type X gypsum wallboard applied around TS4x4x0.188 tube steel column
and held in place with paper masking tape. Second layer 1/2" type X gypsum wallboard
applied around column and held in place with paper masking tape. Face layer either 24
ga galvanized steel column cover consisting of two L-shaped sections with snap -lock
sheet steel joints or 22 ga galvanized steel column covers consisting of two L-shaped
sections with lap joints fastened with No. 8x1/2" sheet metal screws 12" o.c.
Horizontal joints staggered 24" between layers.
SCALE: N.T.S.
1 HOUR
FIRE
k�.
i �' %, X
i
Thickness: 43/4"
Approx. Weight: 7.5 psf
Fire Test: ITS J20-06170.1, 4-00
WP 3644
SCALE: N.T.S.
1 HOUR 40 to 44 STC
FIRE SOUND
Thickness: 6 3/4"
Approx. Weight: 8 psf
Fire Test: See WP 3605
(UL R1319-4, 6, 6-17-52;
UL R2717-39, 1-20-66:
UL R3501-52, 3-15-66,
UL Design U305;
ULC Design W301)
Sound Test: Estimated
WP 3380
SCALE: N.T.S.
1 HOUR
FIRE
IM11 Ii 1w,
91
Thickness: 63/4"
Approx. Weight: 8.5 psf
Fire Test: ITS J99-22441.1, 10-99
WP 3661
SCALE: N.T.S.
COLUMNS, NONCOMBUSTIBLE
1 HOUR
FIRE
C.
Fire Test: UL NC505-(1-6), 71 NK2639,
12-23-75;
UL NC505, 77NK1518;
UL Design X526
OCCUPANT LOAD/ EXIT REQUIREMENTS
ROOM
NAME
AREA
OCC.
FACTOR
OCC.
LOAD
EXITS REQ'D
FIRST FLOOR
VESTIBULE
132.3
200
66
(5) EXITS PROVIDED (OK)
LOBBY/ SEATING
515.3
300
1
(1) EXIT PROVIDED (OK)
FRONT DESK
199.5
-
-
(1) EXIT PROVIDED (OK)
OFFICE
139.3
-
-
5 EXITS PROVIDED OK
RESTROOM
30.4
15
29
5 EXITS PROVIDED OK
ELEVATOR
73.8
-
-
(5) EXITS PROVIDED (OK)
STAIR
167
-
-
(1) EXIT PROVIDED (OK)
HALLWAY
355.6
300
1
(1) EXIT PROVIDED (OK)
LINEN CHUTE
10.6
-
-
(4) EXIT PROVIDED (OK)
LAUNDRY
264.31
300
1
(2) EXIT PROVIDED (OK)
BREAKFAST
575.21
300
1
(2) EXIT PROVIDED (OK)
PREP
135.2
300
1
(2) EXIT PROVIDED (OK)
FITNESS
296
300
1
(2) EXIT PROVIDED (OK)
HOT TUB
181.9
300
1
(2) EXIT PROVIDED (OK)
MECHNICAL
140
300
1
(2) EXIT PROVIDED (OK)
ELECTRICAL ROOM
108.5
300
1
(2) EXIT PROVIDED (OK)
STAIR
157.21
300
1
(2) EXIT PROVIDED (OK)
RESTROOM
60.9
300
1
(2) EXIT PROVIDED (OK)
SUB TOTAL
3,543
98
(4) EXITSPROVIDEDDRETAILNG
SECOND FLOOR
UNIT 201
305.5
200
4
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 202
245.8
200
2
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 203
256.7
200
2
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 204
305.6
200
3
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 205
252
200
3
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 206
413.9
200
3
(1) EXIT PROVIDED (OK)
UNIT 207
517.8
200
5
1) EXIT PROVIDED OK)
UNIT 208
263
200
5
1 EXIT PROVIDED OK
UNIT 209
249.9
-
-
-
UNIT 210
329.8
-
-
-
UNIT 211
251.1
-
-
-
UNIT 212
329.4
-
-
-
STAIRS
251.1
300
1
-50 ONE EXIT REQ'D
HALLWAY
549.5
-
-
-,50 ONE EXIT REQ'D
GUEST LAUNDRY
43.2
300
1
>50 TWO EXITS REQ'D
HOUSEKEEPING
84.7
300
1
-,50 ONE EXIT REQ'D
ELEVATOR EQUIP. ROOM
59.2
15
24
-,50 ONE EXIT REQ'D
STAIRS
157.5
-
-
-
ELEVATOR
73.8
-
-
-
LAUNDRY CHUTE/ MECH. SHAFTS
30.2
-
-
-
S U B TOTAL
4,969.7
72
;P-50 TWO EXITS RE'D
(3) EXITS PROVIDEDQ(OK)
THIRD FLOOR
UNIT 201
305.5
200
4
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 202
245.8
200
2
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 203
256.7
200
2
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 204
305.6
200
3
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 205
252
200
3
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 206
413.9
200
3
(1) EXIT PROVIDED (OK)
UNIT 207
517.8
200
5
1) EXIT PROVIDED (OK)
UNIT 208
263
200
5
1 EXIT PROVIDED OK
UNIT 209
249.9
-
-
-
UNIT 210
329.8
-
-
-
UNIT 211
251.1
-
-
-
UNIT 212
329.4
-
-
-
STAIRS
251.1
300
1
-,50 ONE EXIT REQ'D
HALLWAY
530.6
-
-
-,50 ONE EXIT REQ'D
STAFF BREAKROOM
135.5
300
1
T50 TWO EXITS REQ'D
HOUSEKEEPING
72.5
300
1
-,50 ONE EXIT REQ'D
STAIRS
157.5
-
-
-
ELEVATOR
73.8
-
-
-
LAUNDRY CHUTE/ MECH. SHAFTS
30.2
-
-
-
S U B TOTAL
4,969.7
-
76
;-50 TWO EXITS
(I EXITS PROVIDED Q(OK)
FOURTH FLOOR
UNIT 201
305.5
200
4
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 202
245.8
200
2
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 203
256.7
200
2
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 204
305.6
200
3
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 205
252
200
3
(1) EXIT PROVIDED EA UNIT (OK)
UNIT 206
413.9
200
3
(1) EXIT PROVIDED (OK)
UNIT 207
517.8
200
5
1) EXIT PROVIDED (OK)
UNIT 208
263
200
5
1 EXIT PROVIDED OK
UNIT 209
249.9
-
-
-
UNIT 210
329.8
-
-
-
UNIT 211
251.1
-
-
-
UNIT 212
329.4
-
-
-
STAIRS
251.1
300
1
-50 ONE EXIT REQ'D
HALLWAY
499.8
-
-
-,50 ONE EXIT REQ'D
BUSINESS CENTER
238.8
300
1
-50 TWO EXITS REQ'D
STAIRS
157.5
-
-
-
ELEVATOR
73.8
-
-
-
LAUNDRY CHUTE/ MECH. SHAFTS
30.2
-
11-
-
S U B TOTAL
4,969.7
74
(3) EXITS PROVIDED>50 TO EXITSQ(OK)
3,543
B L D G TOTAL Fro RS 2-4 F-A 14.909.1
4 STORIES- 18,452.1
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: 4360` 424-0394
Fax: 360 424-5726
6429
EG STERED
HITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
SABER
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
COVERSHEET
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COLUMN - GA FILE NO. CM 1450
SCALE: N.T.S.
COMPUTER FILE NAME
0
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
------------------- ------
2 + 0 0 S 89°59' 13" E 380.00' (380' PLAT) - } - - 3 + 0 0 -
w w w w w w w w w w
30TH ST_T-�'EET
L A I 40.00' I g
c c
w w n 34.00'
-- --- --- --- --- - L� _ _ azv - - - --- ---
a d
° <
4 d 4 d
d 4
d° a Q° d. °
d d ° ° 4 2$,00' a ° �] °
Q d a ° a d a° a a
s a d °
39
- - - - _ °s 1 1 W se�o - - - L x
T O z
A+ll
8.00' w N
17.00' Lu O w `
-1 z
o T s.00' u
1�
19.50' 18.00' ST-
59.50'
a
8.50' 8.50' 8.50' 8.50' 8.50' 8.50' 8.50' 4.00'
T-
1181
9.00' , -1
4.00' Oo
TANK TO�ET
-0 - �
OL
I 5'x12' CONCRETE PAD WITH ° d1
FN�
24.00' BIKE RACK TO ACCOMMODATE
BICYCLES a ° F. F. = 69.60
I d l II ffi
a o
w I I J
I � -
w
U M
o
w
0
z C C C
r L - - U
(n
Q Z �L
8.50' 8.50' 8.50' 8.50' 8.50' 8.50' 8.50' 8.00' 8.00' 8.00' 0 `n
LLI
cnF I� LL n
w 20.00'
84.0 '
vo
p
41L
o 0 0 0 0 o a o LL
LL LI
0
84. 0' +I
8.00'
20.00'
4
16.00'
I o -'To U. 0' 8.50 8.50 8.50 8.00 8.50 8.50 8.50 8.50 8.50 8.00 9.50 �--
.0 8.00' 8.00' 8.00'
F_
� I�
° D D° °b C C C C C C
P 10.00°
8.00
° D P
23.00'
I
0. REVISION DATE I BY 1APPROVED SHEET DESCRIPTION:
Ravnik & Associates- Inc -
d
4 /
d d
a a
<'x
a
x
0
a
0
° d.
0
x In ol
I I i
4
I
R OOOH-II d I I
Lu I I
°
N 10 d I 1
LL
Q Z I I
Lu
� Q
°
I I I i
I I FI
d
I I
4 � I
a
Q I I i
I �
�I
°
I I
_ d a
I I
0 8.00' 8.00'
25.58'
C C
° d d
o � a
1.50' Q
1.00,
4 a
15.00' Q o
a Q
°
a °d
EX. ECOLOGY BLOCK WALL
3
I
I
a
x
�
3
I
I
4+00
SCALE: 1" = 10'
3
x
0+00 SOUTH =
0 5 10 20
3+80 EAST
W W W
SIGN LEGEND
0 "HANDICAPPED PARKING ONLY" R7-8b.
12"x18" "VAN ACCESSIBLE" R7-8P5, 12"x6"
a
x
0
STRIPING LEGEND
ST- TYPICAL 4" WIDE YELLOW PAINT LINES
AND BORDER (2 COATS) PER WSDOT
STD PLAN M-17.10-02 FOR A VAN
a
ACCESSIBLE STALL.
I
TYPICAL ACCESS PARKING SPACE SYMBOL
(WSDOT STANDARD SIZE) CONSISTING OF A
WHITE WHEEL CHAIR SYMBOL UPON A BLUE
BACKGROUND HAVING A WHITE BORDER PER
WSDOT STD PLAN M-24.60-02.
TYPICAL 4" WIDE WHITE PAINT STALL STRIPE
o
(2 COATS)
PARKING REQUIREMENTS:
�I
a
1 STALL/GUEST ROOM
O
'O
0
ONE THIRD OF PARKING STALLS MAY BE COMPACT
O
ONE BICYCLE RACK PER 5 PARKING STALLS SHALL BE
O
PROVIDED. RACK TO ACCOMMODATE 7 BICYCLES.
_
O
N E3
36 MOTEL ROOMS REQUIRES 36 ONSITE PARKING STALLS
w
0
ONSITE PARKING PROVIDED = 36 STALLS
�
M
O
zl
STANDARD STALL: MUST BE AT LEAST 8.5 FEET WIDE AND
°
a
AT LEAST 18' DEEP.
I
0
COMPACT STALL: MUST BE AT LEAST 8.0 FEET WIDE AND
-
AT LEAST 16' DEEP.
C = COMPACT PARKING STALL (STENCILED WHITE
T 1 +00
COMPACT LETTERS 12 HIGH)
CAR CHARGING STATIONS: SHALL BE PROVIDED FOR A
MINIMUM 20% OF THE PROVIDED ONSITE PARKING.
THEREFORE, 8 CAR -CHARGING STATIONS SHALL BE
PROVIDED AT THE LOCATIONS DENOTED AS � TO SERVE
TWO STALLS EACH.
a
I �
I
I
I
a
0
I
I
I �
LAN STATUS:
I
SCALE: 1"=10' SHEET TITLE:
DRAWN BY: D. REMSEN 3002
CHECKED BY: J. RAVNIK
DATE: 06.13.19
ENGINEER I DATE
THIS PLAN SHEET IS ACCEPTED FOR CONSTRUCTION IN ACCORDANCE WITH THE CITY OF
ANACORTES ORDINANCES AND POLICIES. ACTUAL CONFORMANCE OF THE DESIGN WITH
APPLICABLE LAWS IS THE SOLE RESPONSIBILITY OF THE PROFESSIONAL ENGINEER, WHOSE
NAME AND STAMP APPEAR ON THIS SHEET. ACQUIRING, COMPLYING WITH, AND PROVIDING
MITIGATION FOR ALL FEDERAL, STATE, COUNTY, AND LOCAL LAWS, PERMITS, AND MANDATES,
INCLUDING BUT NOT LIMITED TO THE ENDANGERED SPECIES ACT, FEDERAL WETLAND PERMIT,
STATE DEPARTMENT OF FISHERIES AND HYDRAULICS PERMIT, FEDERAL FLOOD PLAIN
PERMITS, NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT IS THE
RESPONSIBILITY OF THE DEVELOPER, LAND OWNER, AND THEIR ENGINEER. THE ISSUANCE OF
THIS PERMIT SHALL NOT BE CONSTRUED AS PROOF OF COMPLIANCE WITH APPLICABLE
LAWS AND PERMIT REQUIREMENTS.
-------------------------------
CITY ENGINEER DATE
CONSTRUCTION FOR THE ACCEPTED PROJECT IS TO START WITHIN
1 YEAR OF THE DATE.
SALISH INN
"Q" AVENUE (907 30TH STREET)
FOR
EK TERA ASARA, LLC
SECTION 30 T. 35 N., R. 2 E., W.M.
DRAWING NO.
18025.SITE.dwg
JOB NO.
18025
SHEET NO.
10 OF 17
FLOOR PLAN NOTE&
1, VIDE BARRIER FREE SIG E AT ALL ADA RESTROOMS
CONFIRM ALL ROUGH OPENINGS DOORS AND WINDOWS PRIOR TO
FRAMING AND ORDERING.
3. CONFIRM ALL FINISHES W/ OWNER AN CONTRAC
TO ORDERING.
4_ CONTRACTOR TO COORDINATE BUILDING AL RM/SECURITY
SYSTEM W/ OWNER PRIOR TO DRYWALL INSTALLATION.
5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL CASEWORK FOR
APPROVAL BY ARCHITECT/ OWNER PRIOR TO CONSTRUCTION:
6. SOUND INSULATE ALL WALLS TYP_ THROUGH -OUT.
7. SEE WALL TYPE DETAILS 1-20/A-7.1 AND 22-37/A-7.1A
& HEAT FOR THE CORE SPACE WILL BE GAS PACK UNITS ON THE ROOF
W/ DIFFUSERS AS REQUIRED. COORDINATE LOCATIONS OF DIFFUSERS
AS REQUIRED WITH LIGHTING, REFER TO MECHANICAL DRAWINGS TYP.
THE MOTEL UNITS WILL BE HEATED BY P-TAC ELECTRIC HEATERS TYP.
PER MECHANICAL DRAWINGS TYP,
9. ALL RESTROOMS TO HAVE GREEN GWB TYPICAL ALL WALLS AND CEILING.
10. VENT HOT WATER TANK OUTSIDE AS REQUIRED. PROVIDE RELIEF VALVE
PAN, AND SEISMIC STRAPPING AS REQUIRED.
11, ALL WINDOWS ARE TO RECEIVE SOLID SURFACE SILL
12. DUCTS MAY NOT PENETRATE FIRE BARRIER BETWEEN UNITS WITHOUT
DAMPERS PER IBC 717.5.2. (NOTED AT INTERCONNECTED BATH FANS)
1�
1. 3'-0'
D
a
i
n - CD -
p
2.0' 8' CMU
COLUMN
WRAP
"
6X6 HSS
-4.
"
(Dc)
0
c
8' CMU
COLUMN
WRAP
0
cV 1
N
21'-10'
E
-4.
7
0
d-
DS I
PARKING
119
EXIT PLAN NOTES:
1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-0' PER
TABLE 1014.3 (OK)
2. OVERALL EXIT TRAVEL DISTANCE < 200'-0' FOR t10151.
00Ca ITH
SPRINKLERS PER TABLE 1016.2 (OK)
3. (7) EXITS PROVIDED AND (3) ARE REQUIRED PER CIE WE HAVE
BETWEEN 501 AND 1000 OCCUPANT LOAD. (OK)
4. WHERE 2 EXITS ARE REQUIRED WE HAVE MET THE REQUIREMENT THAT
THE EXITS DOORS ARE GREATER THAN 1/3 THE DIAGONAL DISTANCE
APART OF THE OCCUPANT AREA SERVED PER 1015.2-1 EXCEPTION 2, (OK)
EGRESS WIDTH PER OCCUPANT SERVED 638 OCCUPANTS (PER COVER
SHEET) (.20) INCHES PER OCCUPANT (PER TABLE xxx WITH (I-2)
OCCUPANCIES WITH SPRINKLER SYSTEM ) 638 X (.20) 128 INCHES.
WE PROVIDED (7) EXIT DOORS (46+46+46+46+46+46+46) 322 INCHES
WHICH IS > 128 INCHES (OK)
INSTALL EXIT LIGHTS & FIRE EXTINGUISHERS SHOWN ON PLAN AND
AS DIRECTED BY THE FIRE MARSHALL
m
"
I
I
IIBREAKFAST
108
M
20'-11r
5
FLOOR PLAN LEGEND
EXIT
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE W/ BATTERY
�
SEE WALL TYPES DETAILS ON SHEET A-6,1
BACKUP
BUILDING DOWN SPOUT LOCATIONS
COMBINATION EXIT SIGN/EMERGENCY LIGHTING WITH
o DS
6' m FLOOR DRAIN. SLOPE FLOOR TO DRAIN
EXIT
BATTERY BACKUP HARDWARE
O FD
FREEZE PROOF HOSE BIB. PER MECHANICAL
EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
+ H �
STRUCTRUAL POST OR BUNDLED STUDS. OR HSS
❑FE
2A 1OBC SEMI -RECESSED FIRE EXTINGUISHER SEE
El [3
SIZE PER STRUCTURAL
FLOOR PLAN SHEETS FOR LOCATIONS
Ox
DOOR NUMBER SEE SHEET A-2,5 FOR SCHEDULE
OR
CLASS I STANDPIPE IN STAIR LANDINGS
AND ROOF AS REQ'D BY FIRE MARSHALL
OWINDOW
NUMBER SEE SHEET A-2.5 FOR SCHEDULE
AND 905 OF THE IBC
X X X
ROOM FINISH TAG SEE SHEET A-2.6 FOR SCHEDULE
Lei
4' CMU VENEER W/ REINFORCEMENT
(1) HOUR STRUCTURAL/ BEARING WALL - 2 X 6 WD FRAMED
WALLS 0 16' O,C: W/ EXTERIOR SIDING PER ELEVATIONS,
- 0/ TYVEK COMMERCICAL WRAP 0/ 1/2' EXT. SHEATHING PER STRUCT. W/ R-21
BATT INSULATION W/ INTERIOR V.B. W/ (1) LAYER 5/8' TYPE 'X' GWB
LEVEL 4 FINISH, PNT.
0 INTERIOR WALLS TO BE 2 X _ WD FRAMING
0 16' O.C. W/ 5/8' TYPE 'X' GWB BOTH SIDES, TAPED. MUDDED.
AND SANDED, LEVEL 4 FINISH, PNT. BOTH SIDES W/ SOUND BATT
INSULATION 0 COMMON SPACES ONLY. INTERIOR OFUNITS NO INSULATION
FRAME ALL WALLS TO BOTTOM OF (1) HOUR CLG ASSEMBLY CLG GWB
TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE
CAULK/ SEAL GWB TO CLG, SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
0 2-HOUR WALL AT STAIR AND ELEVATOR ENCLOSURES. (2) LAYERS I' 'X' GWB
EA. SIDE OF 2X6 WOOD STUDS 0 16' O.C, SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
(1/21 HOUR UNIT SEPARATION WALLS TO BE 2 X 6 P.T. WD SILL PLATE
0 W/ 2X4 STUDS 0 8' O.C. STAGGERED EA. SIDE W/ R-21 BATT
INSULATION W/ ON 1/2' RC CHANNEL 5/8' TYPE 'X' GWB BOTH SIDES.
LEVEL 4 FINISH, PNT. BOTH SIDES TYP. FRAME ALL WALLS
TO BOTTOM OF (1) HOUR CEILING ASSEMBLY U.N.O. CLG GWB TO BE
INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB, FIRE CAULK/
SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
l3 i -
7 95'-0' -4.1 8 9 10 11
73'- 21 PROVIDE POWER FOR
DS AUTO/OPEN PUSH BUTTONS
18 _ AT VESTIBULE DOORS
13'-4' -6• BOTH SETS ADJUST 38'-10r
:6TQR_ERRG_NIT AS R9QUIRE-9
E CONC.
O SIDEWALK
SLOPE AWAY
I
VESTIBULE -6r 11'-8' 9'-21'
100 x
- - - - F 1 - -
-4.
AUTO EN
PISH BUTTON 2'-21 3 __W
1 O DS O HB H1 DS �/
O
I
O EXIT O F I ®R
LI Y,
-1 STAIR
111 4'-0'
I I
LOBBY 0 I I SEATING
101 110
I 110
GAS FIREPLACE V.Ta .
WITH MANTLE AND I
HEARTH SURROUND
1
I 1 I
I cof ee
I I
0
0 R R.0 F.D. COD l
c9 RE ;,c, -I 109 FLOOR
0 SINK
Y II /u \ II S 1 RECESSED 17
IL---- I I I 0 15
9'-4' 9'-2r 2'-10i' 16-3 ' W 0 8'-2' 4'-8' 6'-2f
_ `" HALL 19
O rn O
6'-1 '-3' 6'-3' 3'-6' 3'- 114
/ R "
16
FLOOR
SINK
RECESSED
13'-5'
10'-1'
12
0)
ELECTRICAL ; I
ROOM
112 O
4
SWBD.
O
HWT HWT
MECHANICAL
113 F.Do O
SPRINK,
Ln
nuuu d-.
FITNESS
JA
115
Dc
DN O Cq
F
I I O
4'-1ALUMI UM ENCING
PREP I �SYSTE W/ TEMPERED
116 GLAZING
11 -'X
XI I I I I I o HOT
.
DRYER VaTaOa .+ 118 -6.3 '
-s.3 w F 0 I.C. I I I I I HB
Q V.T.O,
COLUMN I } DRYER I I I I I I I 1 RIEF 8' CMU
WRAP I o F.O.LC, PROVIDE POWER,
DISCONNECT AND DRAIN COLUMN
G \ ®R WRAP \ G
1
H S - DS O O DS -� - - - _ DS� - - - -�-- 3-1-H1---- 5'-0' I- � ----��
3'_0' I 2 8'-g' I 2'-5�' 6'-6' I 6' 5' 6'-0' I ALUMINUM FENCING
6X6 HSS t6.0) �_ � - - SYSTEM W/ TEMPERS 6X6 HSS
13 7� 27 7�' GLAZING
E
1 2 -4 2 . 3 4 g 4.7 5 6 6.97 ° 8) 8. � 9 19.9 41 10.9 11 12
FIRST F 00 PLAN
SCALE: 1/4'=1'-0' -
UF -11
107
I I
I I
WASHER
F.O�LC.
I F.D.
�? 10
o
F SHER
I I
II
II � o
II
II
II
II � II
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
424-0394
Fax: 424-5726
6429
REG STERED
HITECT
IPETER TTI
STATE 0 WASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
[rA E
�M R
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
Al 8/27/19 PERMIT REVISIONS
2 9/16/19 PERMIT REVISIONS
SHEET TITLE:
FIRST FLOOR PLAN
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
o
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
FLOOR PLAN NOTES:
1. PROVIDE BARRIER FREE SIGNAGE AT ALL ADA RESTROOMS
2. CONFIRM ALL ROUGH OPENINGS FOR DOORS AND WINDOWS PRIOR TO
FRAMING AND ORDERING.
3. CONFIRM ALL FINISHES W/ OWNER AND CONTRACTOR PRIOR
TO ORDERING.
4. CONTRACTOR TO COORDINATE BUILDING ALARM/SECURITY
SYSTEM W/ OWNER PRIOR TO DRYWALL INSTALLATION.
5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL CASEWORK FOR
APPROVAL BY ARCHITECT/ OWNER PRIOR TO CONSTRUCTION.
6. SOUND INSULATE ALL WALLS TYP. THROUGH -OUT.
7. SEE WALL TYPE DETAILS 1-20/A-7.1 AND 22-37/A-7.1A
8. HEAT FOR THE CORE SPACE WILL BE GAS PACK UNITS ON THE ROOF
W/ DIFFUSERS AS REQUIRED. COORDINATE LOCATIONS OF DIFFUSERS
AS REQUIRED WITH LIGHTING. REFER TO MECHANICAL DRAWINGS TYP.
THE MOTEL UNITS WILL BE HEATED BY P-TAC ELECTRIC HEATERS TYP.
PER MECHANICAL DRAWINGS TYP.
9. ALL RESTROOMS TO HAVE GREEN GWB TYPICAL ALL WALLS AND CEILING.
10. VENT HOT WATER TANK OUTSIDE AS REQUIRED. PROVIDE RELIEF VALVE
PAN. AND SEISMIC STRAPPING AS REQUIRED.
11. ALL WINDOWS ARE TO RECEIVE SOLID SURFACE SILL
12. DUCTS MAY NOT PENETRATE FIRE BARRIER BETWEEN UNITS WITHOUT
DAMPERS PER IBC 717.5.2. (NOTED AT INTERCONNECTED BATH FANS)
EGE
0
N
E
0
N
N
G
z
C
N
EXIT PLAN NOTES:
1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-0' PER
TABLE 1014.3 (OK)
2. OVERALL EXIT TRAVEL DISTANCE < 200'-0' FOR (I-2) OCC. WITH
SPRINKLERS PER TABLE 1016.2 (OK)
3. (7) EXITS PROVIDED AND (3) ARE REQUIRED PER 1015.1.1. SINCE WE HAVE
BETWEEN 501 AND 1000 OCCUPANT LOAD. (OK)
4. WHERE 2 EXITS ARE REQUIRED WE HAVE MET THE REQUIREMENT THAT
THE EXITS DOORS ARE GREATER THAN 1/3 THE DIAGONAL DISTANCE
APART OF THE OCCUPANT AREA SERVED PER 1015.2.1 EXCEPTION 2. (OK)
5. EGRESS WIDTH PER OCCUPANT SERVED 638 OCCUPANTS (PER COVER
SHEET) (.20) INCHES PER OCCUPANT (PER TABLE xxx WITH (I-2)
OCCUPANCIES WITH SPRINKLER SYSTEM ) 638 X (.20) - 128 INCHES.
WE PROVIDED (7) EXIT DOORS (46+46+46+46+46+46+46) - 322 INCHES
WHICH IS > 128 INCHES (OK)
6. INSTALL EXIT LIGHTS & FIRE EXTINGUISHERS SHOWN ON PLAN AND
AS DIRECTED BY THE FIRE MARSHALL
FLOOR PLAN LEGEND
EX TITI
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE W/ BATTERY
�
SEE WALL TYPES DETAILS ON SHEET A-6.1
BACKUP
BUILDING DOWN SPOUT LOCATIONS
COMBINATION EXIT SIGN/EMERGENCY LIGHTING WITH
DS
6' 0 FLOOR DRAIN. SLOPE FLOOR TO DRAIN
EXIT
BATTERY BACKUP HARDWARE
O FD
FREEZE PROOF HOSE BIB. PER MECHANICAL
EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
+ HB
STRUCTRUAL POST OR BUNDLED STUDS. OR HSS
❑FE
2A 1OBC SEMI -RECESSED FIRE EXTINGUISHER SEE
I 1 ❑
SIZE PER STRUCTURAL
FLOOR PLAN SHEETS FOR LOCATIONS
0 DOOR NUMBER SEE SHEET A-2.5 FOR SCHEDULE ®R CLASS I STANDPIPE IN STAIR LANDINGS
AND ROOF AS REQ'D BY FIRE MARSHALL
OWINDOW NUMBER SEE SHEET A-2.5 FOR SCHEDULE AND 905 OF THE IBC
X X X ROOM FINISH TAG SEE SHEET A-2.6 FOR SCHEDULE
4' CMU VENEER W/ REINFORCEMENT
(1) HOUR STRUCTURAL/ BEARING WALL - 2 X 6 WD FRAMED
WALLS 0 16' O.C. W/ EXTERIOR SIDING PER ELEVATIONS.
- 0/ TYVEK COMMERCICAL WRAP 0/ 1/2' EXT. SHEATHING PER STRUCT. W/ R-21
BATT INSULATION W/ INTERIOR V.B. W/ (1) LAYER 5/8' TYPE 'X' GWB
LEVEL 4 FINISH. PNT.
0 INTERIOR WALLS TO BE 2 X _ WD FRAMING
0 16' O.C. W/ 5/8' TYPE 'X' GWB BOTH SIDES. TAPED, MUDDED,
AND SANDED. LEVEL 4 FINISH. PNT. BOTH SIDES W/ SOUND BATT
INSULATION 0 COMMON SPACES ONLY. INTERIOR OFUNITS NO INSULATION
FRAME ALL WALLS TO BOTTOM OF (1) HOUR CLG ASSEMBLY CLG GWB
TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE
CAULK/ SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
0 2-HOUR WALL AT STAIR AND ELEVATOR ENCLOSURES. (2) LAYERS I' 'X' GWB
EA. SIDE OF 2X6 WOOD STUDS 0 16' O.C. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
(1/21 HOUR UNIT SEPARATION WALLS TO BE 2 X 6 P.T. WD SILL PLATE
0 W/ 2X4 STUDS 0 8' O.C. STAGGERED EA. SIDE W/ R-21 BATT
INSULATION W/ ON 1/2' RC CHANNEL 5/8' TYPE 'X' GWB BOTH SIDES.
LEVEL 4 FINISH. PNT. BOTH SIDES TYP. FRAME ALL WALLS
TO BOTTOM OF (1) HOUR CEILING ASSEMBLY U.N.O. CLG GWB TO BE
INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE CAULK/
SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
SECOND FLOOR PLAN �\
scnLe va',r.o' -)
Fl/
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
601 424-0394
Fax: 424-5726
6429
EG STERED
ITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
WFJR
CONSTRUCTION
360.354.3500
19-312
REVISIONS
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECOND FLOOR PLAN
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A===:-- 0
COPYRIGHT 2019 CARLETTI ARCHITECTS, P.S.
AG
FLOOR PLAN NOTES:
1. PROVIDE BARRIER FREE SIGNAGE AT ALL ADA RESTROOMS
2. CONFIRM ALL ROUGH OPENINGS FOR DOORS AND WINDOWS PRIOR TO
FRAMING AND ORDERING.
3. CONFIRM ALL FINISHES W/ OWNER AND CONTRACTOR PRIOR
TO ORDERING.
4. CONTRACTOR TO COORDINATE BUILDING ALARM/SECURITY
SYSTEM W/ OWNER PRIOR TO DRYWALL INSTALLATION.
5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL CASEWORK FOR
APPROVAL BY ARCHITECT/ OWNER PRIOR TO CONSTRUCTION.
6. SOUND INSULATE ALL WALLS TYP. THROUGH -OUT.
7. SEE WALL TYPE DETAILS 1-20/A-7.1 AND 22-37/A-7.1A
8. HEAT FOR THE CORE SPACE WILL BE GAS PACK UNITS ON THE ROOF
W/ DIFFUSERS AS REQUIRED. COORDINATE LOCATIONS OF DIFFUSERS
AS REQUIRED WITH LIGHTING. REFER TO MECHANICAL DRAWINGS TYP.
THE MOTEL UNITS WILL BE HEATED BY P-TAC ELECTRIC HEATERS TYP.
PER MECHANICAL DRAWINGS TYP.
9. ALL RESTROOMS TO HAVE GREEN GWB TYPICAL ALL WALLS AND CEILING.
10. VENT HOT WATER TANK OUTSIDE AS REQUIRED. PROVIDE RELIEF VALVE
PAN. AND SEISMIC STRAPPING AS REQUIRED.
11. ALL WINDOWS ARE TO RECEIVE SOLID SURFACE SILL
12. DUCTS MAY NOT PENETRATE FIRE BARRIER BETWEEN UNITS WITHOUT
DAMPERS PER IBC 717.5.2. (NOTED AT INTERCONNECTED BATH FANS)
1 2
3
EXIT PLAN NOTES:
1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-0' PER
TABLE 1014.3 (OK)
2. OVERALL EXIT TRAVEL DISTANCE � 200'-0' FOR (I-2) OCC. WITH
SPRINKLERS PER TABLE 1016.2 (OK)
3. (7) EXITS PROVIDED AND (3) ARE REQUIRED PER 1015.1.1. SINCE WE HAVE
BETWEEN 501 AND 1000 OCCUPANT LOAD. (OK)
4. WHERE 2 EXITS ARE REQUIRED WE HAVE MET THE REQUIREMENT THAT
THE EXITS DOORS ARE GREATER THAN 1/3 THE DIAGONAL DISTANCE
APART OF THE OCCUPANT AREA SERVED PER 1015.2.1 EXCEPTION 2. (OK)
5. EGRESS WIDTH PER OCCUPANT SERVED 638 OCCUPANTS (PER COVER
SHEET) (.20) INCHES PER OCCUPANT (PER TABLE xxx WITH (I-2)
OCCUPANCIES WITH SPRINKLER SYSTEM ) 638 X (.20) - 128 INCHES.
WE PROVIDED (7) EXIT DOORS (46+46+46+46+46+46+46) - 322 INCHES
WHICH IS � 128 INCHES (OK)
6. INSTALL EXIT LIGHTS & FIRE EXTINGUISHERS SHOWN ON PLAN AND
AS DIRECTED BY THE FIRE MARSHALL
0
Le
FLOOR PLAN LEGEND
EX TI
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE W/ BATTERY
�
SEE WALL TYPES DETAILS ON SHEET A-6.1
BACKUP
BUILDING DOWN SPOUT LOCATIONS
COMBINATION EXIT SIGN/EMERGENCY LIGHTING WITH
Im DS
6' m FLOOR DRAIN. SLOPE FLOOR TO DRAIN
EXIT
BATTERY BACKUP HARDWARE
O FD
FREEZE PROOF HOSE BIB. PER MECHANICAL
EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
+HB
STRUCTRUAL POST OR BUNDLED STUDS. OR HSS
[:]FP-
2A 1OBC SEMI -RECESSED FIRE EXTINGUISHER SEE
00 ❑
SIZE PER STRUCTURAL
FLOOR PLAN SHEETS FOR LOCATIONS
0 DOOR NUMBER SEE SHEET A-2.5 FOR SCHEDULE ®R CLASS I STANDPIPE IN STAIR LANDINGS
AND ROOF AS REQ'D BY FIRE MARSHALL
OWINDOW NUMBER SEE SHEET A-2.5 FOR SCHEDULE AND 905 OF THE IBC
X X X ROOM FINISH TAG SEE SHEET A-2.6 FOR SCHEDULE
7
10
4' CMU VENEER W/ REINFORCEMENT
(11 HOUR STRUCTURAL/ BEARING WALL - 2 X 6 WD FRAMED
WALLS 0 16' O.C. W/ EXTERIOR SIDING PER ELEVATIONS.
- 0/ TYVEK COMMERCICAL WRAP 0/ 1/2' EXT. SHEATHING PER STRUCT. W/ R-21
BATT INSULATION W/ INTERIOR V.B. W/ (1) LAYER 5/8' TYPE 'X' GWB
LEVEL 4 FINISH. PNT.
0 INTERIOR WALLS TO BE 2 X - WD FRAMING
0 16' O.C. W/ 5/8' TYPE 'X' GWB BOTH SIDES. TAPED, MUDDED,
AND SANDED. LEVEL 4 FINISH. PNT. BOTH SIDES W/ SOUND BATT
INSULATION 0 COMMON SPACES ONLY. INTERIOR OFUNITS NO INSULATION
FRAME ALL WALLS TO BOTTOM OF (1) HOUR CLG ASSEMBLY CLG GWB
TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE
CAULK/ SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
0 2-HOUR WALL AT STAIR AND ELEVATOR ENCLOSURES. (2) LAYERS I' 'X' GWB
EA. SIDE OF 2X6 WOOD STUDS 0 16' O.C. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
(1/21 HOUR UNIT SEPARATION WALLS TO BE 2 X 6 P.T. WD SILL PLATE
0 W/ 2X4 STUDS 0 8' O.C. STAGGERED EA. SIDE W/ R-21 BATT
INSULATION W/ ON 1/2' RC CHANNEL 5/8' TYPE 'X' GWB BOTH SIDES.
LEVEL 4 FINISH. PNT. BOTH SIDES TYP. FRAME ALL WALLS
TO BOTTOM OF (1) HOUR CEILING ASSEMBLY U.N.O. CLG GWB TO BE
INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE CAULK/
SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
�1 2� �2�3) 4�q 4.7 5 U6 6.97 9�91i ,16. 10� 11 12
THIRD FLOOR PLAN �'� Ak
SCALE: 1/4'=1'-0' VF)
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: 4360� 424-0394
Fax: 360 424-5726
TERED
ITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
VrA
AMER
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
THIRD FLOOR PLAN
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A - 2 o 2
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
FLOOR PLAN NOTES:
FLOOR PLAN LEGEND
1. PROVIDE BARRIER FREE SIGNAGE AT ALL ADA RESTROOMS
2. CONFIRM ALL ROUGH OPENINGS FOR DOORS AND WINDOWS PRIOR TO
FRAMING AND ORDERING.
3. CONFIRM ALL FINISHES W/ OWNER AND CONTRACTOR PRIOR
TO ORDERING.
4. CONTRACTOR TO COORDINATE BUILDING ALARM/SECURITY
SYSTEM W/ OWNER PRIOR TO DRYWALL INSTALLATION.
5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL CASEWORK FOR
APPROVAL BY ARCHITECT/ OWNER PRIOR TO CONSTRUCTION.
6. SOUND INSULATE ALL WALLS TYP. THROUGH -OUT.
7. SEE WALL TYPE DETAILS 1-20/A-7.1 AND 22-37/A-7.1A
8. HEAT FOR THE CORE SPACE WILL BE GAS PACK UNITS ON THE ROOF
W/ DIFFUSERS AS REQUIRED. COORDINATE LOCATIONS OF DIFFUSERS
AS REQUIRED WITH LIGHTING. REFER TO MECHANICAL DRAWINGS TYP.
THE MOTEL UNITS WILL BE HEATED BY P-TAC ELECTRIC HEATERS TYP.
PER MECHANICAL DRAWINGS TYP.
9. ALL RESTROOMS TO HAVE GREEN GWB TYPICAL ALL WALLS AND CEILING.
10. VENT HOT WATER TANK OUTSIDE AS REQUIRED, PROVIDE RELIEF VALVE
PAN, AND SEISMIC STRAPPING AS REQUIRED.
11. ALL WINDOWS ARE TO RECEIVE SOLID SURFACE SILL
12. DUCTS MAY NOT PENETRATE FIRE BARRIER BETWEEN UNITS WITHOUT
DAMPERS PER IBC 717.5.2. (NOTED AT INTERCONNECTED BATH FANS)
0
d-
0
cV
O
to
0
cV
N
G
H
co
0
EXIT PLAN NOTES:
1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-0' PER
TABLE 1014.3 (OK)
2. OVERALL EXIT TRAVEL DISTANCE < 200'-0' FOR (I-2) OCC. WITH
SPRINKLERS PER TABLE 1016.2 (OK)
3. (7) EXITS PROVIDED AND (3) ARE REQUIRED PER 1015.1.1. SINCE WE HAVE
BETWEEN 501 AND 1000 OCCUPANT LOAD. (OK)
4. WHERE 2 EXITS ARE REQUIRED WE HAVE MET THE REQUIREMENT THAT
THE EXITS DOORS ARE GREATER THAN 1/3 THE DIAGONAL DISTANCE
APART OF THE OCCUPANT AREA SERVED PER 1015.2.1 EXCEPTION 2. (OK)
5. EGRESS WIDTH PER OCCUPANT SERVED 638 OCCUPANTS (PER COVER
SHEET) (.20) INCHES PER OCCUPANT (PER TABLE xxx WITH (I-2)
OCCUPANCIES WITH SPRINKLER SYSTEM ) 638 X (.20) - 128 INCHES.
WE PROVIDED (7) EXIT DOORS (46#46+46+46+46+46+46) - 322 INCHES
WHICH IS T 128 INCHES (OK)
6. INSTALL EXIT LIGHTS & FIRE EXTINGUISHERS SHOWN ON PLAN AND
AS DIRECTED BY THE FIRE MARSHALL
EXIT
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE W/ BATTERY
�
SEE WALL TYPES DETAILS ON SHEET A-6.1
BACKUP
BUILDING DOWN SPOUT LOCATIONS
COMBINATION EXIT SIGN/EMERGENCY LIGHTING WITH
DS
6' m FLOOR DRAIN, SLOPE FLOOR TO DRAIN
EXIT
BATTERY BACKUP HARDWARE
O FD
FREEZE PROOF HOSE BIB, PER MECHANICAL
EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
+ H
STRUCTRUAL POST OR BUNDLED STUDS. OR HSS
❑FE
2A 1OBC SEMI -RECESSED FIRE EXTINGUISHER SEE
❑ ❑
SIZE PER STRUCTURAL
FLOOR PLAN SHEETS FOR LOCATIONS
�x DOOR NUMBER SEE SHEET A-2.5 FOR SCHEDULE OR CLASS I STANDPIPE IN STAIR LANDINGS
AND ROOF AS REQ'D BY FIRE MARSHALL
OWINDOW NUMBER SEE SHEET A-2.5 FOR SCHEDULE AND 905 OF THE IBC
X X X ROOM FINISH TAG SEE SHEET A-2.6 FOR SCHEDULE
4' CMU VENEER W/ REINFORCEMENT
(11 HOUR STRUCTURAL/ BEARING WALL - 2 X 6 WD FRAMED
WALLS 0 16' O.C. W/ EXTERIOR SIDING PER ELEVATIONS.
- 0/ TYVEK COMMERCICAL WRAP 0/ 1/2' EXT. SHEATHING PER STRUCT. W/ R-21
BATT INSULATION W/ INTERIOR V.B. W/ (1) LAYER 5/8' TYPE 'X' GWB
LEVEL 4 FINISH. PNT.
0 INTERIOR WALLS TO BE 2 X - WD FRAMING
e 16' O.C. W/ 5/8' TYPE 'X' GWB BOTH SIDES, TAPED, MUDDED,
AND SANDED. LEVEL 4 FINISH. PNT. BOTH SIDES W/ SOUND BATT
INSULATION 0 COMMON SPACES ONLY. INTERIOR OFUNITS NO INSULATION
FRAME ALL WALLS TO BOTTOM OF (1) HOUR CLG ASSEMBLY CLG GWB
TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE
CAULK/ SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
0 2-HOUR WALL AT STAIR AND ELEVATOR ENCLOSURES. (2) LAYERS I' 'X' GWB
EA. SIDE OF 2X6 WOOD STUDS a 16' O.C. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
(1/2) HOUR UNIT SEPARATION WALLS TO BE 2 X 6 P.T. WD SILL PLATE
0 W/ 2X4 STUDS 0 8' O.C. STAGGERED EA. SIDE W/ R-21 BATT
INSULATION W/ ON 1/2' RC CHANNEL 5/8' TYPE 'X' GWB BOTH SIDES.
LEVEL 4 FINISH. PNT. BOTH SIDES TYP. FRAME ALL WALLS
TO BOTTOM OF (1) HOUR CEILING ASSEMBLY U.N.O. CLG GWB TO BE
INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE CAULK/
SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
FOURTH FLOOR PLAN A
\
SCALE: 1/4'=1'-0' w
/
m N&
:E)
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60� 424-0394
Fax: 424-5726
6�?LEG�STERED
ITECT
STATE OKIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
1MERrA
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
FOURTH FLOOR PLAN
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A 2o #/'�
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
ROOF NOTES:
❑ INDICATES 3 X 4 RECTANGULAR SMOOTH
FACED DOWNSPOUT TIGHTLINE AS REQUIRED.
1. ALL ROOFS SLOPES ARE AS NOTED.
2. ALL ROOF OVERHANGS ARE AS NOTED.
3. CONNECT ALL DOWNSPOUTS TO TIGHTLINES
AS REQUIRED, COORDINATE ALL DOWNSPOUT
LOCATIONS WITH CIVIL.
4. LOCATE ALL DOWNSPOUTS SO AS NOT TO
INTERFERE W/ WINDOWS OR DOORWAYS.
3. PROVIDE AND INSTALL STEP FLASHING AS REQ'D.
4. SIZE OF GUTTERS & DOWNSPOUTS TO BE
OVERSIZED WHERE NECESSARY TO HANDLE
RAINWATER FROM VALLEYS AND ROOF SURFACES.
5. PLUMBING/ELEC./MECH. SUBCONTRACTORS TO
PROVIDE/ INSTALL FLASHING BOOTS AT ALL ROOF
PENETRATIONS TYP.
6. ALL RAKE. SAVE. AND VALLEY FLASHING TO
BE SHEET METAL TYPICAL.
7. PROVIDE AND INSTALL SHEET METAL AND
PARAPET CAP FLASHING AS REQUIRED.
8. PROVIDE MIN 1/8' SLOPED CRICKETS AT ALL ROOF
OPENINGS AND PARAPET WALLS FOR DRAINAGE
TO Ar[IPPFPA TYP
(I
- ----(�A)
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60` 424-0394
Fax: 424-5726
6429
REG STERED
IA ITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
C 905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
' DD
E
i
E
1 2 -4 '2.9& 4 ; 4. `5 6 6. 7 ° 8 8� gOC' 1)
12
IABER
CONSTRUCTION
360.354.3500
rlompi
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
ROOF PLAN
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
ROOF PLAN �\
SCALE: 1/4'=1'-0' w
/
A
COPYRIGHT 2010 CARLETTI ARCHITECTS. P.S.
GENERAL BUILDING DOOR SCHEDULE
NO.
SIZE
DOOR LEAF
FRAME
HARDWARE RATING
NOTES
TYPE
MAT'L.
FIN.
MAT'L.
FIN.
CLSR.
PANIC
GRP.
1
(2) 3'-0' X T-O'
F
ALUM.
FF
ALUM.
FF
YES
YES
-
-
KEYED LOCK, WEATHERSTRIP, THRESHOLD, SWEEP, DEADBOLT, TUBULAR PUSH/PULL, CONTINUOUS HINGE, OVERHEAD CONCEALED CLOSER, AUTO OPENER POWER
2
(2) 3'-0' X T-O'
F
ALUM.
FF
ALUM.
FF
YES
YES
-
-
KEYED LOCK. WEATHERSTRIP. THRESHOLD, SWEEP, DEADBOLT. TUBULAR PUSH/PULL, CONTINUOUS HINGE. OVERHEAD CONCEALED CLOSER, AUTO OPENER POWER
3
3'-0' X T-0'
A
HMD
PNT
HMF
PNT
-
-
-
-
KEYED LOCK WITH INTEGRAL MORTISED DEADBOLT, INSULATED, WEATHERSTRIP. THRESHOLD, SWEEP, DRIP HEAD
4
3'-0' X T-O'
A
HMD
PNT
HMF
PNT
-
-
-
-
KEYED LOCK WITH INTEGRAL MORTISED DEADBOLT, INSULATED, WEATHERSTRIP. THRESHOLD, SWEEP. DRIP HEAD
5
3'-0' X T-O'
A
HMD
PNT
HMF
PNT
-
-
-
-
KEYED LOCK WITH INTEGRAL MORTISED DEADBOLT. INSULATED. WEATHERSTRIP. THRESHOLD. SWEEP, DRIP HEAD
6
3'-0' X T-O'
F
HMD
PNT
HMF
PNT
-
-
-
-
KEYED LOCK WITH INTEGRAL MORTISED DEADBOLT, INSULATED, WEATHERSTRIP. THRESHOLD. SWEEP, DRIP HEAD
7
3'-0' X T-O'
H
HMD
PNT
HMF
PNT
YES
YES
-
-
KEYED LOCK WITH INTEGRAL MORTISED DEADBOLT, INSULATED, WEATHERSTRIP, THRESHOLD, SWEEP, DRIP HEAD
8
3'-0' X T-0'
A
WD
PNT
-
-
-
-
-
-
POCKET DOOR WITH BARRIER FREE HARDWARE, PRIVACY LOCK
9
3'-0' X T-0'
A
WD
PNT
HMF
PNT
-
-
-
-
LEVER HARDWARE WITH KEYED LOCKSET
10
3'-0' X T-O'
A
WD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HARDWARE WITH KEYED LOCKSET
10B
3'-0' X T-O'
A
WD
PNT
HMF
PNT
YES
-
-
145 MIN.
LEVER HANDLE KEYED LOCKSET ELECTRONIC CARD SWIPE, S.S. KICKPLATES
11
3'-0' X T-O'
H
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
12
3'-0' X T-O'
A
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE, STAINLESS STEEL KICKPLATES, KEYKED LOCKSET THRESHOLD, WEATHERSTRIP
13
4'-0' X T-0'
A
HMD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE KEYED LOCKSET. ELECTRONIC CARDSWIPE. STAINLESS STEEL KICKPLATES.THRESHOLD
14
(2) 3'-0' X T-0'
F
WD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PASSAGE SET
15
3'-0' X T-O'
A
WD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
16
3'-0' X T-O'
H
WD
PNT
HMF
PNT
YES
-
-
-
LEVER HANDLE, STAINLESS STEEL KICKPLATES, KEYED LOCKSET
17
3'-0' X T-0'
H
HMD
PNT
HMF
PNT
YES
-
-
190 MIN.
LEVER HANDLE, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
18
NOT USED
19
3'-0' X T-0'
H
HMD
PNT
HMF
PNT
YES
-
-
-
LEVER HANDLE PASSAGE SET
20
2'-0' X 4'-0'
A
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET
21
3'-0' X T-O'
H
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
22
2'-0' X 4'-0'
A
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET
23
3'-0' X T-O'
A
HMD
PNT
HMF
PNT
YES
45 MIN.
LEVER HANDLE KEYED LOCKSET
24
3'-0' X T-O'
H
HMD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE KEYED LOCKSET, ELECTRONIC CARD SWIPE
25
4'-0' X T-0'
A
HMD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE PASSAGE LOCKSET
26
3'-0' X T-0'
H
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
27
3'-0' X T-O'
H
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
28
2'-0' X 4'-0'
A
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET
29
3'-0' X T-O'
A
HMD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE KEYED LOCKSET ELECTRONIC CARD SWIPE. S.S. KICKPLATES
30
3'-0' X T-O'
A
HMD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE KEYED LOCKSET ELECTRONIC CARD SWIPE, S.S. KICKPLATES
31
3'-0' X 7'-0'
H
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET. STAINLESS STEEL KICKPLATES, THRESHOLD. WEATHERSTRIP
32
3'-0' X T-0'
H
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
33
2'-0' X 4'-0'
A
HMD
PNT
HMF
PNT
YES
-
-
90 MIN.
LEVER HANDLE PASSAGE SET
34
3'-0' X T-O'
H
HMD
PNT
HMF
PNT
YES
45 MIN.
LEVER HANDLE KEYED LOCKSET ELECTRONIC CARD SWIPE, S.S. KICKPLATES
34B
3'-0' X T-O'
H
HMD
PNT
JHMF
I PNT
YES
-
-
45 MIN.
LEVER HANDLE KEYED LOCKSET ELECTRONIC CARD SWIPE. S.S. KICKPLATES
35
1 3'-0' X T-0'
IH
I HMD
PNT
JHMF
I PNT
I YES-F-
-
90 MIN.
I LEVER HANDLE PASSAGE SET, STAINLESS STEEL KICKPLATES, THRESHOLD, WEATHERSTRIP
NOTES:
1. ALL DOORS TO BE 1 3/4' THICK. ALL WOOD DOORS OUTSIDE OF UNITS OR DOORS FROM
CORRIDOR TO UNIT TO BE SOLID CORE. ALL INTERIOR DOORS IN UNITS TO BE SOLID CORE
2. VERIFY ALL R.O. AND JAMB DEPTHS PRIOR TO ORDERING.
3. ALL DOORS TO HAVE BARRIER FREE HARDWARE AS REQUIRED.
4. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
5. ALL GLAZING WITHIN A 24 INCH ARC OF EITHER EDGE OF DOORS
AND WITHIN 18 INCHES OF FLOORS SHALL BE SAFTEY GLAZING AS
REQUIRED BY IBC SECTION 2406. ALL SUCH GLAZING SHALL HAVE
PERMANENT IDENTIFICATION SAFETY GLAZING STAMP.
6. DOORS SHALL HAVE LEVER HARDWARE WHICH WILL PERMIT OPERATION
BY WRIST OR ARM PRESSURE.
7. ALL DOORS W/ DEADBOLTS MUST HAVE SINGLE ACTION OPERATION BY
HANDLE INSIDE AND KEY ON THE EXTERIOR MORTISE LOCKS
8. FINISH OF ALL STOREFRONT TO BE CLEAR ANODIZED
9. ALL EXTERIOR DOORS TO BE UA .60 OR BETTER
10. ALL DOOR/GATE HARDWARE TO BE ADA COMPLIANT. MEET SECTION 1010 OF THE IBC
T- TEMPERED
A B C D E F H
TEMPERED
(WIRED GLASS AT
RATED DOORS)
OR 'FIRELITE' GLAZING
UNITS BUILDING DOOR SCHEDULE
NO.
QTY.
SIZE
DOOR LEAF
FRAME
HARDWARE RATING
NOTES
TOTAL
TYPE
MAT'L.
FIN.
MAT'L.
FIN.
CLSR.
PANIC
GRP.
36
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD. SWEEP, DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
37
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
38
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
WIRE PULLS
39
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE, WEATHERSTRIP, THRESHOLD, SWEEP, DEADBOLT. PEEPHOLE, DOOR SECURITY LATCH
40
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
LEVER HANDLE PRIVACY LOCKSET
41
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
42
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD. SWEEP, DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
43
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
44
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
45
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE, WEATHERSTRIP, THRESHOLD, SWEEP, DEADBOLT. PEEPHOLE, DOOR SECURITY LATCH
46
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
LEVER HANDLE PRIVACY LOCKSET
47
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
48
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD. SWEEP, DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
49
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
50
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
IWIRE PULLS
51
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.1
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE, WEATHERSTRIP, THRESHOLD, SWEEP, DEADBOLT. PEEPHOLE, DOOR SECURITY LATCH
52
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
LEVER HANDLE PRIVACY LOCKSET
53
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
54
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD. SWEEP, DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
55
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
56
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
-
-
LEVER HANDLE PRIVACY LOCKSET
57
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PASSAGE SET
58
3
6-0' X T-O'
C
ALUM
FF
-
-
-
-
-
SLIDING GLASS DOOR WITH TEMPERED GLAZING
59
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE, WEATHERSTRIP, THRESHOLD. SWEEP. DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
60
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
ILEVER HANDLE PRIVACY LOCKSET
61
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
62
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD. SWEEP, DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
63
3
2'-8' X T-O'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
64
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
65
2
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE, WEATHERSTRIP, THRESHOLD. SWEEP. DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
66
2
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
-
LEVER HANDLE PRIVACY LOCKSET
67
2
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
66B
1
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
WIRE PULLS
66C
1
2'-8' X T-O'
A
WOOD
PNT
HMF
PNT
-
-
LEVER HANDLE PRIVACY LOCKSET
68
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET, ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD, SWEEP, DEADBOLT, PEEPHOLE, DOOR SECURITY LATCH
69
3
2'-8' X T-O'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
70
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
WIRE PULLS
71
3
3'-0' X 7'-0'
A
WOOD
PNT
HMF
PNT
YES
-
-
45 MIN.
LEVER HANDLE LOCKSET. ELECTRONIC CARDSWIPE. WEATHERSTRIP. THRESHOLD. SWEEP. DEADBOLT. PEEPHOLE. DOOR SECURITY LATCH
72
3
2'-8' X T-0'
A
WOOD
PNT
HMF
PNT
-
-
-
-
LEVER HANDLE PRIVACY LOCKSET
73
3
3'-0' X 7'-0'
B
WOOD
PNT
HMF
PNT
-
-
-
-
WIRE PULLS
WINDOW SCHEDULE FOR GENERAL BUILDING-
(NON UNITS)
NO.
QTY.
SIZE
TYPE
FRAME
U-VALUE
NOTES
TOTAL
MAT'L.
FIN.
A
1
6'-0'
X
5'-0'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON
B
1
4'-6'
X
5'-0'
FIXED
ALUM
FF
.30
ILOW
E
GLAZING. ARGON
C
1
8'-10'
X
8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON
D
1
12'-4'
X
8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON
E
1
8'-10'
X
8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON. SEE DOOR SCHEDULE
F
1
8'-10'
X
8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON, SEE DOOR SCHEDULE
G
1
12'-5
1/2' X 8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON
H
6
3'-0'
X
3'-4'
FIXED
ALUM
FF
.30
LOW
E
GLAZING. ARGON
H1
8
3'-0'
X
3'-4'
FIXED
VINYL
FF
.30
LOW
E
GLAZING.
ARGON
I
3
6'-0'
X
8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON
J
3
6'-0'
X
8'-6'
FIXED
ALUM
FF
.30
LOW
E
GLAZING.
ARGON
K
1
6'-0'
X
2'-0'
FIXED
VINYL
FF
.30
LOW
E
GLAZING.
ARGON
M
36
6'-0'
X
4'-0'
FIXED
VINYL
FF
.30
LOW
E
GLAZING.
ARGON
N
3
3'-0'
X
3'-6'
FIXED
VINYL
FF
.30
LOW
E
GLAZING. ARGON
P
NOT
USED
Q
1
6'-0'
X
6'-0'
FIXED
VINYL
FF
1.30
LOW
E
GLAZING.
ARGON
R
1 2
3'-0'
X
6'-O'
FIXED
WOOD
PNT.
00
O O OSTOREFRONT
OSTOREFRONT
00
a
T-TEMPERED
00
0�
OSTOREFRONT
9
O ALUM
VINYL
0000
I
I
I I I
I I
00�0
OSTOREFRONT
< STOREFRONT
OSTOREFRONT O O O
NOTES:
1. ALL GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE
THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24' ARC OR EITHER
VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE
BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60' ABOVE THE
WALKING SURFACE SHALL BE TEMPERED.
(GLAZING SUBCONTRACTOR TO VERIFY LOCATIONS) OF ALL SAFTEY GLAZING.)
2. GLAZING SHALL BE TEMPERED IN AN INDIVIDUAL FIXED OR OPERABLE PANEL,
OTHER THAN THOSE LOCATIONS
DESCRIBED IN ITEM 1. ABOVE, THAT MEETS ALL THE FOLLOWING CRITERIA.
A) EXPOSED AREA OF INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET.
B) EXPOSED BOTTOM EDGE IS LESS THAN 18' ABOVE THE FLOOR.
C) EXPOSED TOP EDGE GREATER THAN 36' ABOVE THE FLOOR.
D) ONE OR MORE WALKING SURFACES WITHIN 36' ABOVE THE FLOOR.
3. REFER TO THE DOOR SCHEDULE FOR SIZE OF ALL DOORS WITH GLAZING.
4. SEE BUILDING ELEVATIONS FOR MUTTON, LOUVER AND DOOR PLACEMENTS
5. ALL WINDOW SIZES ARE ROUGH OPENINGS AND SHALL BE FIELD MEASURED
PRIOR TO FABRICATION.
6. CONTRACTOR TO VERIFY ALL WINDOW QUANTITIES.
7. CONTRACTOR TO VERIFY ALL WINDOW SIZES
8. ALL STOREFRONT TO BE THERMALLY BROKEN.
9. MAX SHGC IS TO BE 0.35
OSTOREFRONT
00
�0
OSTOREFRONT
0
T
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: MO
0I 424-0394
Fax: 424-5726
s4Z,_J(RLEG�STERED
ITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
�rA
MER
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
DOOR SCHEDULE
WINDOW SCHEDULE
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
2.5
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
FINISH SCHEDULE
FIRST FLOOR
FLOOR
BASE
NORTH WALL
SOUTH WALL
EAST WALL
WEST WALL
CEILING
ROOM NUMBER
ROOM NAME
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
HGT.
100
VESTIBULE
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
9'-0'
WOOD CHAIR RAIL PAINTED
101
LOBBY
LVT
FF
LVT-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
9'-0'
WOOD CHAIR RAIL PAINTED
102
OFFICE
CPT.
FF
CPT-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
ACP
FF
9'-0'
103
RESTROOM
LVT
FF
LVT-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-0'
P.LAM. WAINSCOT TO 60' A.F.F.
104
FRONT DESK
CPT.
FF
CPT-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
9'-0'
105
ELEVATOR
LVT
FF
LVT-1
P.LAM
FF
P.LAM-1
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
FF
8'-0'
P.LAM. ALL WALLS WITH STAINELESS STEEL CHAIR RAIL
106
STAIR
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
jGWB
PAINT
GWB
PNT.
-
107
LAUNDRY
LVT
FF
LVT-2
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-0'
F.
108
BREAKFAST
LVT
FP
LVT-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
ACP
FF
8'-0'
WOOD CHAIR RAIL PAINTED
109
RESTROOM
LVT
FF
LVT-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-0'
TILE WAINSCOT TO 60' A.F.F.
110
SEATING
CPT
FF
CPT-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
FF
8'-0'
WOOD CHAIR RAIL PAINTED
111
STAIR
SV
FF
SV-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
FF
-
112
ELECTRICAL ROOM
CONC.
SEAL
FF
VRB
FF
VRB -1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
9'-6'
113
MECHANICAL ROOM
CONC.
SEAL
FF
VRB
FF
VRB -1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
9'-6'
114
HALL
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
ACP
FF
8'-0'
WOOD CHAIR RAIL PAINTED
115
FITNESS
LVT
FF
LVT-1
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
ACP
FF
9-0'
116
PREP
LVT
FP
LVT-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
FF
9'-6'
P.LAM. WAINSCOT TO 60' A.F.F.
117
HOUSEKEEPING
LVT
FF
LVT-1
VRB
FF
VRB -1
1 GWB
I PAINTI
GWB
PAINT
GWB
PAINT
GWB
PAINT
IGWB
PNT.
8'-6'
118
HOT TUB
CONC.
SEAL
I -
-
I
-
-
-
-
-
-
I GWB
FF
9'-6'
EXTERIOR GYPSUM WITH PLASTER FINISH AT CEILING
119
PARKING
ASPHALT
FF
-
I -
I -
-
I
I-
-
1
-
-
1
1-
-
jGWB
FF
9'-6'
EXTERIOR GYPSUM WITH PLASTER FINISH AT CEILING
FINISH SCHEDULE
SECOND FLOOR
FLOOR
BASE
NORTH WALL
SOUTH WALL
EAST WALL
WEST WALL
CEILING
ROOM NUMBER
ROOM NAME
MAT'L FIN. NO.
MAT'L FIN. NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
HGT.
NOTES:
213
STAIRS
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PNT.
-
214
ELEVATOR
LVT
FF
LVT-1
P.LAM
FF
P.LAM-1
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
FF
8'-0'
215
ELEVATOR EQUIPMENT
LVT
FF
LVT-1
VRB
FF
VRB -1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
W-6'
216
HOUSEKEEPING
LVT
FF
LVT-1
VRB
FF
VRB -1
I
PNT.
8'-6'
217
GUEST LAUNDRY
LVT
FF
LVT-1
VRB
FF
VRB -1
PNT.
8'-6'
218
HALL
CPT
FF
CPT-2
WD
PNT.
PNT-1
1 8'-0'
213
STAIRS ___tCPT
FF
CPT-2
WD
PNT.
PNT-1
PNT.
8'-6'
FINISH SCHEDULE
THIRD FLOOR
FLOOR
BASE
NORTH WALL
SOUTH WALL
EAST WALL
WEST WALL
CEILING
ROOM NUMBER
ROOM NAME
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
HGT.
NOTES:
313
STAIRS
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
-
314
ELEVATOR
LVT
FF
LVT-1
P.LAM
FF
P.LAM-1
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
FF
8'-0'
315
HOUSEKEEPING
LVT
FF
LVT-1
VRB
FF
VRB -1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
316
HOUSEKEEPING
LVT
FF
LVT-1
VRB
FF
VRB -1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
317
IHALL
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
ACP
FF
8'-0'
318
ISTAIRS
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
-
FINISH SCHEDULE
FOURTH FLOOR
FLOOR
BASE
NORTH WALL
SOUTH WALL
EAST WALL
WEST WALL
CEILING
ROOM NUMBER
NAME
MAT'L
FIN.
NO.MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
HGT.
NOTES:
413
STAIRS
CPT
FF
CPT-2
WD
PNT.
PNT-1
PNT.
-
414
ELEVATOR
LVT
FF
LVT-1
P.LAM
FF
P.LAM-1
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
P.LAM.
FF
FF
8'-0'
415
CONFERENCE ROOM
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
416
HALL
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
ACP
FF
8'-0'
- 417STAIRS
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
-
HOUSEKEEPING
LVT
FF
LVT-1
VRB
FF
VRB -1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
FINISH SCHEDULE
UNITS
FLOOR BASE
NORTH WALL
SOUTH WALL
EAST WALL
WEST WALL
CEILING NOTES:
ROOM NUMBER
ROOM NAME
MAT'L
FIN.
NO.MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
NO.
MAT'L
FIN.
HGT.
201/301/401
UNIT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
202/302/402
UNIT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
203/303/403
IT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
204/304/404
IT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
205/30
I
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
206/306/406
1N209/309/409
UNIT
CPT
FF
CPT-2
WD
PNT.
PNT-1
PNT.
8'-6'
207/307/407
IT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
W-6'
208/308/408
UNIT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
IT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
210/310/410
IT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
211/311/411
UNIT
CPT
FF
CPT-2
WD
PNT.
PNT-1
PNT.
8'-6'
212/312/412
UNIT
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
201B/301B/401B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
I PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
202B/302B/402B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
jGWB
PAINT
I
GWB
PNT.
8'-6'
203B/303B/403B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
jGWB
PAINT
GWB
PNT.
8'-6'
204B/304B/404B
BATH
TILE
FF
T-1
TILE
FF
T-1
I
PNT.
8'-6'
205B/305B/405B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
206B/306B/406B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
207B/307B/407B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
207C/307C/407C
BEDROOM
CPT
FF
CPT-2
WD
PNT.
PNT-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
208B/308B/4088
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
209B/309B/409B
BATH
TILE
FF
T-1
TILE
FF
T-1
PNT.
8'-6'
21OB31OB/410B
BATH
TILE
FF
T-1
TILE
FF
T-1
PNT.
8'-6'
211B/311B/411B
BATH
TILE
FF
T-1
TILE
FF
T-1
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PAINT
GWB
PNT.
8'-6'
212B/312B/412B
BATH
TILE
FF
T-1
TILE
FF
T-1
PNT.
8'-6'
TILE
FF
T-1
TILE
FF
T-1
8'-6'
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60� 424-0394
Fax: 424-5726
6�rEGSTERED
H I TECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
! rA
MEN
OR
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
FINISH SCHEDULE
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
2o6
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
LEGEND
SURFACE MOUNTED 6' X 4'-0' LED STRIP LIGHT z RECESSED 2' X 2' LED TROFFER W/ ACRYLIC LENS AT (KITCHEN, SURFACE MOUNTED LED STRIP LIGHTING AT (UTILITY ROOMS)
AT STAIR LANDINGS STORAGE, LAUNDRY, ART, BREAK) � 22' X 36' (1) HOUR RATED ACCESS HATCH IN TRUSSES FOR
ATTIC ACCESS. LOCATION ON RCP ARE APPROXIMATE
SURFACE MOUNTED 36' DIA. LED LIGHT (LOBBY HIGH CEILING RECESSED 2' X 4' LED ACRYLIC LENS AT (KITCHEN. ART. LAUNDRY. EXTERIOR - TRACK LIGHTING MOUNT TO BEAM AT (6) LOCATIONS TYPICAL
o L
AND DINING HIGH CEILING) STORAGE. BREAK) PORTE CO CHERE
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE
WALL MOUNT LED UP -DOWN SCONCE AT (CORRIDOR/ ELEVATOR/ ® W/ BATTERY BACKUP
SURFACE MOUNTED 24' LED LIGHT (COFFEE/ SITTING/ FIRE SIDE/ 4 LOBBY/ STAIRWELLS)
�r- INTERIOR -TRACK LIGHTING MOUNT TO CEILING AT (STORE)
O SKY LOUNGE/ ELEVATOR LOBBY/ LOBBY/ FAMILY DINING) � COMBINATION EXIT SIGN/EMERGENCY LIGHTING
CABLE HUNG LED PENDANT LIGHTS AT (BISTRO/ RECEPTION/ CEILING HUNG LED CHANDELIER AT DINING WITH BATTERY BACKUP HARDWARE
a WALL MOUNTED 6' X 3'-0' LED RESTROOM VANITY STORE) EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
LIGHT ABOVE MIRROR W/ (3) BULB DOWN -LIGHT AT (PUBLIC RR/ COVED LIGHTING LED AT (DINING) EXTERIOR RATED LED WALL MOUNTED DECORATIVE DOWN
STAFF RR/ SALON/ SPA/ BATHING/ -----'
® 0 SURFACE MOUNTED 12' LED LIGHT AT (RESIDENT BEDROOMS) LIGHTS AT EXTERIOR DECKS AND ENTRANCE DARK BRONZE FINISH $ SWITCHES PER ELECTRICAL
EXTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH 0 DELIVERY
ENTRANCE TO KITCHEN Q EXTERIOR 10' DIA X 12' TALL CYLINDER CABLE HUNG ® EXHAUST FAN V.T.O. AS REQUIRED PER MECHANICAL DRAWINGS
SURFACE MOUNTED 18' LED LIGHT AT (RESIDENT LIVING/ KITCHEN) DARK BRONZE FINISH
0 INTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH THROUGHOUT NOTES:
® RECESSED 2' X 2' LED TROFFER DIFFUSED CENTER OPTIC WALL MOUNTED 6' X 2'-0' LED RESIDENT RESTROOM VANITY 1. LOCATE ALL DIFFUSERS & RETURN AIR GRILLES
AT CORRIDORS, OFFICES. BOWLING. GAME. SALON, SPA, BATH. ° CABLE HUNG LED PENDANT LIGHTS AT (RESIDENT ROOMS) LIGHT ABOVE MIRROR W/ (2) BULB DOWN -LIGHT AT (RESIDENT SO AS NOT TO INTERFERE W/ LIGHTS.
STORE, FAMILY DINING. LOBBY, EXERCISE) - NL NIGHT LIGHT OUTLET LED LIGHTS AT (RESIDENT RESTROOMS) RESTROOMS)
2. ALL EXTERIOR LIGHTS TYPICAL (INCLUDING SITE LIGHTING)
® RECESSED 2' X 4' LED TROFFER DIFFUSED CENTER OPTIC m INTERIOR - 4' LED CAN W/ CLEAR ALZAK TO BE ON AN ASTROLOGICAL CLOCK PHOTOCELL SO THEY COME ON
AT (OFFICES, HIGH STAIR) OS AUDIO SPEAKERS (T.B.D.) FINISH AUTOMATIC WHEN IT IS DARK OUT.
FLOOR ABOVE
9
L
DVVC
l 11 �Z.
FIRST FLOOR REFLECTED CEILING PLAN
B
4 5 6 7 -4 8
I
9 10 11 12
-- ROOF ABOVE
I FLOOR ABOVE I FLOOR ABOVE \—FLOOR ABOVE
4 4. (5 6 6.97 ° 8 8. 9 C99 A4 109 11 12
SCALE: 1/4'=1'-0' w
— -----(�B)
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60� 424-0394
Fax: 424-5726
6�EGSTERED
IA HITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
�rA
MER
coNsrRucnoN
360.354.3500
19-312
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
FIRST FLOOR REFLECTED CLG.
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
I n /
A - 07
COPYRIGHT 2019 CARLETTI ARCHITECTS, P.S
LEGEND
SURFACE MOUNTED 6' X 4'-0' LED STRIP LIGHT z RECESSED 2' X 2' LED TROFFER W/ ACRYLIC LENS AT (KITCHEN, SURFACE MOUNTED LED STRIP LIGHTING AT (UTILITY ROOMS)
AT STAIR LANDINGS STORAGE, LAUNDRY, ART, BREAK) El ATTIC
X 36' (1) HOUR RATED ACCESS HATCH IN TRUSSES FOR
ATTIC ACCESS. LOCATION ON RCP ARE APPROXIMATE
SURFACE MOUNTED 36' DIA. LED LIGHT (LOBBY HIGH CEILING RECESSED 2' X 4' LED ACRYLIC LENS AT (KITCHEN. ART, LAUNDRY. EXTERIOR - TRACK LIGHTING MOUNT TO BEAM AT (6) LOCATIONS TYPICAL
o L
AND DINING HIGH CEILING) STORAGE. BREAK) PORTE CO CHERE
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE
WALL MOUNT LED UP -DOWN SCONCE AT (CORRIDOR/ ELEVATOR/ ® W/ BATTERY BACKUP
° SURFACE MOUNTED 24' LED LIGHT (COFFEE/ SITTING/ FIRE SIDE/ a LOBBY/ STAIRWELLS) COMBINATION
INTERIOR -TRACK LIGHTING MOUNT TO CEILING AT (STORE)
O SKY LOUNGE/ ELEVATOR LOBBY/ LOBBY/ FAMILY DINING) � COMBINATION EXIT SIGN/EMERGENCY LIGHTING
CABLE HUNG LED PENDANT LIGHTS AT (BISTRO/ RECEPTION/ CEILING HUNG LED CHANDELIER AT DINING WITH BATTERY BACKUP HARDWARE
a WALL MOUNTED 6' X 3'-0' LED RESTROOM VANITY STORE) EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
LIGHT ABOVE MIRROR W/ (3) BULB DOWN -LIGHT AT (PUBLIC RR/ STAFF RR/ SALON/ SPA/ BATHING/ COVED LIGHTING LED AT (DINING) EXTERIOR RATED LED WALL MOUNTED DECORATIVE DOWN
------
®
EXTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH ®DELIVERY SURFACE MOUNTED 12' LED LIGHT AT (RESIDENT BEDROOMS) LIGHTS AT EXTERIOR DECKS AND ENTRANCE DARK BRONZE FINISH $ SWITCHES PER ELECTRICAL
ENTRANCE TO KITCHEN 0 EXTERIOR 10' DIA X 12' TALL CYLINDER CABLE HUNG OF EXHAUST FAN V.T.O. AS REQUIRED PER MECHANICAL DRAWINGS
SURFACE MOUNTED 18' LED LIGHT AT (RESIDENT LIVING/ KITCHEN) DARK BRONZE FINISH
0 INTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH THROUGHOUT NOTES:
® RECESSED 2' X 2' LED TROFFER DIFFUSED CENTER OPTIC WALL MOUNTED 6' X 2'-0' LED RESIDENT RESTROOM VANITY 1. LOCATE ALL DIFFUSERS & RETURN AIR GRILLES
AT CORRIDORS. OFFICES. BOWLING. GAME. SALON, SPA. BATH. ° CABLE HUNG LED PENDANT LIGHTS AT (RESIDENT ROOMS) LIGHT ABOVE MIRROR W/ (2) BULB DOWN -LIGHT AT (RESIDENT SO AS NOT TO INTERFERE W/ LIGHTS.
STORE. FAMILY DINING. LOBBY. EXERCISE) - NL NIGHT LIGHT OUTLET LED LIGHTS AT (RESIDENT RESTROOMS) RESTROOMS)
2. ALL EXTERIOR LIGHTS TYPICAL (INCLUDING SITE LIGHTING)
® RECESSED 2' X 4' LED TROFFER DIFFUSED CENTER OPTIC m INTERIOR - 4' LED CAN W/ CLEAR ALZAK TO BE ON AN ASTROLOGICAL CLOCK PHOTOCELL SO THEY COME ON
AT (OFFICES. HIGH STAIR) OS AUDIO SPEAKERS (T.B.D.) FINISH AUTOMATIC WHEN IT IS DARK OUT.
E
T
T
3 4 5) � 7
i
0 2
SECOND
42(3
FLOOR PLAN
4 � 9 10 11 12
Fl/
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
601 424-0394
Fax: 424-5726
6429
EG STERED
ITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
WFJR
CONSTRUCTION
360.354.3500
19-312
REVISIONS
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECOND FLOOR REFLECTED CLG.
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A 2 0
COPYRIGHT 2019 CARLETTI ARCHITECTS, P.S
Ilk
SCALE: 1/4'=1'-0' W)
LEGEND
V
/1
F
SURFACE MOUNTED 6' X 4'-0' LED STRIP LIGHT
AT STAIR LANDINGS
SURFACE MOUNTED 36' DIA. LED LIGHT (LOBBY HIGH CEILING
AND DINING HIGH CEILING)
SURFACE MOUNTED 24' LED LIGHT (COFFEE/ SITTING/ FIRE SIDE/
SKY LOUNGE/ ELEVATOR LOBBY/ LOBBY/ FAMILY DINING)
WALL MOUNTED 6' X 3'-0' LED RESTROOM VANITY
LIGHT ABOVE MIRROR W/ (3) BULB DOWN -LIGHT AT (PUBLIC RR/
STAFF RR/ SALON/ SPA/ BATHING/
EXTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH 0 DELIVERY
ENTRANCE TO KITCHEN
INTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH THROUGHOUT
RECESSED 2' X 2' LED TROFFER DIFFUSED CENTER OPTIC
AT CORRIDORS. OFFICES. BOWLING. GAME. SALON, SPA. BATH.
STORE, FAMILY DINING. LOBBY, EXERCISE)
RECESSED 2' X 4' LED TROFFER DIFFUSED CENTER OPTIC
AT (OFFICES. HIGH STAIR)
RECESSED 2' X 2' LED TROFFER W/ ACRYLIC LENS AT (KITCHEN.
STORAGE. LAUNDRY. ART. BREAK)
RECESSED 2' X 4' LED ACRYLIC LENS AT (KITCHEN. ART. LAUNDRY.
STORAGE. BREAK)
4 WALL MOUNT LED UP -DOWN SCONCE AT (CORRIDOR/ ELEVATOR/
LOBBY/ STAIRWELLS)
CABLE HUNG LED PENDANT LIGHTS AT (BISTRO/ RECEPTION/
STORE)
------ COVED LIGHTING LED AT (DINING)
SURFACE MOUNTED 12' LED LIGHT AT (RESIDENT BEDROOMS)
SURFACE MOUNTED 18' LED LIGHT AT (RESIDENT LIVING/ KITCHEN)
C CABLE HUNG LED PENDANT LIGHTS AT (RESIDENT ROOMS)
NL NIGHT LIGHT OUTLET LED LIGHTS AT (RESIDENT RESTROOMS)
QS AUDIO SPEAKERS (T.B.D.)
SURFACE MOUNTED LED STRIP LIGHTING AT (UTILITY ROOMS)
EXTERIOR - TRACK LIGHTING MOUNT TO BEAM AT
PORTS CO CHERE
INTERIOR - TRACK LIGHTING MOUNT TO CEILING AT (STORE)
CEILING HUNG LED CHANDELIER AT DINING
EXTERIOR RATED LED WALL MOUNTED DECORATIVE DOWN
LIGHTS AT EXTERIOR DECKS AND ENTRANCE DARK BRONZE FINISH
O EXTERIOR 10' DIA X 12' TALL CYLINDER CABLE HUNG
DARK BRONZE FINISH
WALL MOUNTED 6' X 2'-0' LED RESIDENT RESTROOM VANITY
LIGHT ABOVE MIRROR W/ (2) BULB DOWN -LIGHT AT (RESIDENT
RESTROOMS)
m INTERIOR - 4' LED CAN W/ CLEAR ALZAK
FINISH
22' X 36' (1) HOUR RATED ACCESS HATCH IN TRUSSES FOR
ATTIC ACCESS. LOCATION ON RCP ARE APPROXIMATE
(6) LOCATIONS TYPICAL
® DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE
W/ BATTERY BACKUP
COMBINATION EXIT SIGN/EMERGENCY LIGHTING
WITH BATTERY BACKUP HARDWARE
EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
$ SWITCHES PER ELECTRICAL
Q EXHAUST FAN V.T.O. AS REQUIRED PER MECHANICAL DRAWINGS
NOTES:
1. LOCATE ALL DIFFUSERS & RETURN AIR GRILLES
SO AS NOT TO INTERFERE W/ LIGHTS.
2. ALL EXTERIOR LIGHTS TYPICAL (INCLUDING SITE LIGHTING)
TO BE ON AN ASTROLOGICAL CLOCK PHOTOCELL SO THEY COME ON
AUTOMATIC WHEN IT IS DARK OUT.
4 � 9 10 11 12
i
I I I
4 4 4. 5 6 6. 7 8) 8. 9 9. 4 10. 11 12
THIRD' FLOORP�_AN Ak
SCALE: 1/4'=1'-0' VF)
A
-4.
0
IN
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60� 424-0394
Fax: 424-5726
TERED
ITECT
STATE ORIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
VrA
AMER
CONSTRUCTION
360.354.3500
19-312
REVISIONS
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
THIRD FLR REFLECTED CLG.
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
����71�i�i����►_1r71:
A 2o�)
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S
LEGEND
SURFACE MOUNTED 6' X 4'-0' LED STRIP LIGHT z RECESSED 2' X 2' LED TROFFER W/ ACRYLIC LENS AT (KITCHEN. SURFACE MOUNTED LED STRIP LIGHTING AT (UTILITY ROOMS)
AT STAIR LANDINGS STORAGE. LAUNDRY. ART. BREAK) ❑A 22' X 36' (1) HOUR RATED ACCESS HATCH IN TRUSSES FOR
ATTIC ACCESS. LOCATION ON RCP ARE APPROXIMATE
SURFACE MOUNTED 36' DIA. LED LIGHT (LOBBY HIGH CEILING RECESSED 2' X 4' LED ACRYLIC LENS AT (KITCHEN, ART, LAUNDRY, EXTERIOR - TRACK LIGHTING MOUNT TO BEAM AT (6) LOCATIONS TYPICAL
o L
AND DINING HIGH CEILING) STORAGE. BREAK) PORTE CO CHERE
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE
WALL MOUNT LED UP -DOWN SCONCE AT (CORRIDOR/ ELEVATOR/ O ® W/ BATTERY BACKUP SURFACE MOUNTED 24' LED LIGHT (COFFEE/ SITTING/ FIRE SIDE/ 4 LOBBY/ STAIRWELLS)
INTERIOR -TRACK LIGHTING MOUNT TO CEILING AT (STORE)
O SKY LOUNGE/ ELEVATOR LOBBY/ LOBBY/ FAMILY DINING► COMBINATION EXIT SIGN/EMERGENCY LIGHTING
CABLE HUNG LED PENDANT LIGHTS AT (BISTRO/ RECEPTION/ CEILING HUNG LED CHANDELIER AT DINING WITH BATTERY BACKUP HARDWARE
a WALL MOUNTED 6' X 3'-0' LED RESTROOM VANITY STORE) EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
LIGHT ABOVE MIRROR W/ (3) BULB DOWN -LIGHT AT (PUBLIC RR/ COVED LIGHTING LED AT (DINING) EXTERIOR RATED LED WALL MOUNTED DECORATIVE DOWN
STAFF RR/ SALON/ SPA/ BATHING/ ------
® SURFACE MOUNTED 12' LED LIGHT AT (RESIDENT BEDROOMS) LIGHTS AT EXTERIOR DECKS AND ENTRANCE DARK BRONZE FINISH $ SWITCHES PER ELECTRICAL
EXTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH 0 DELIVERY
ENTRANCE TO KITCHEN O EXTERIOR 10' DIA X 12' TALL CYLINDER CABLE HUNG ® EXHAUST FAN V.T.O. AS REQUIRED PER MECHANICAL DRAWINGS
SURFACE MOUNTED 18' LED LIGHT AT (RESIDENT LIVING/ KITCHEN) DARK BRONZE FINISH
0 INTERIOR - 6' LED CAN W/ CLEAR ALZAK FINISH THROUGHOUT NOTES:
® RECESSED 2' X 2' LED TROFFER DIFFUSED CENTER OPTIC WALL MOUNTED 6' X 2'-0' LED RESIDENT RESTROOM VANITY 1. LOCATE ALL DIFFUSERS & RETURN AIR GRILLES
AT CORRIDORS. OFFICES, BOWLING. GAME. SALON. SPA. BATH. ° CABLE HUNG LED PENDANT LIGHTS AT (RESIDENT ROOMS) LIGHT ABOVE MIRROR W/ (2) BULB DOWN -LIGHT AT (RESIDENT SO AS NOT TO INTERFERE W/ LIGHTS.
STORE, FAMILY DINING, LOBBY, EXERCISE) - NL NIGHT LIGHT OUTLET LED LIGHTS AT (RESIDENT RESTROOMS) RESTROOMS)
2. ALL EXTERIOR LIGHTS TYPICAL (INCLUDING SITE LIGHTING)
® RECESSED 2' X 4' LED TROFFER DIFFUSED CENTER OPTIC m INTERIOR - 4' LED CAN W/ CLEAR ALZAK TO BE ON AN ASTROLOGICAL CLOCK PHOTOCELL SO THEY COME ON
AT (OFFICES. HIGH STAIRI 0 AUDIO SPEAKERS (T.B.D.) FINISH AUTOMATIC WHEN IT IS DARK OUT.
�Ar
115mll
Nqwl
E
1 2
T
2 D4
FOURTH FLOOR REFLECTED CEILING PLAN
7
10
12
RAJ
_ A
-4.
I
- UF
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
60� 424-0394
Fax: 424-5726
642s
EG STERED
ITECT
STATE OKIWASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS SH037@GMAILCOM
PHONE: 360-770-3701
1MERrA
CONSTRUCTION
360.354.3500
19-312
REVISIONS
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
FOURTH FLR REFLECTED CLG.
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
KelT" Ion Q 0214ailk I_ 819
A-2-10
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
SCALE: 1/4'=1'-0' /
m
00
m
10 F O a D O O O B O e O OO
A A n 24 GA. SHT. METAL -PARAPET CAP
B.O.ot
WINDOW 7'-0' ABOVE
4TH
F.F.
B.O.IF
ot
WINDOW 4'-0' ABOVE
4TH
F.F.
IF
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
B.O.IF
ot WINDOW 7'-0' ABOVE 3RD F.F.
IF
B.O. WINDOW 4'-0' ABOVE 3RD F.F.
T.O. 3RD F.F. 21'-2' A.F.F.
4, B.O. WINDOW T-O' ABOVE 2ND F.F.
B.O. WINDOW 4'-0' ABOVE 2ND F.F.
SOUTH ELEVATION
(D0
J
NORTH ELEVATION
ELEVATION NOTES:
1. CAULK ALL SIDING TRANSITIONS, COLOR TO BE APPROVED BY
ARCHITECT
2. MASONRY SUBCONTRACTOR TO CLEAN AND SEAL ALL CMU AS PER
SPECIFICATIONS
3. COORDINATE ANY SEALING/ CLEANING OF CMU VENEER W/
MANUFACTURES RECOMMENDATIONS.
4. ELEVATIONS SHOW GENERAL LAYOUT OF ELECTRICAL LIGHT
LOCATIONS. VERIFY/ COORDINATE ALL W/ ELEC. DWGS. AND
PROVIDE TRIM AS REQ'D
5. COORDINATE ALL LIGHT FIXTURES WITH ELEC. DWGS.
6. PROVIDE MTL TRIM OVER ALL EXPOSED TOP BEAM SURFACE AREAS
AND RUN DOWN SIDE OF BEAM MIN. 2' AS REQ'D.
7. PROVIDE MTL. FLASHING AT ALL ROOF TO WALL TRANSITIONS.
8. PROVIDE PUTTY PADS AT ALL EXTERIOR ELEC. 'J' BOX LOCATIONS
FOR AIR BARRIER LEAKAGE STANDARDS.
9. ELECTRICIAN TO PROVIDE 20 AMP DEDICATED POWER TO ALL
EXTERIOR SIGNAGE LOCATIONS TYP.
m
SCALE: 1/4'4-0'
T.O. PARAPET 42'-0' A.F.F.
T.O. WINDOW T-O' ABOVE 4TH F.F.
B.O. WINDOW 4'-0' ABOVE 4TH F.F.
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
T.O.
WINDOW T-O'
ABOVE
3RD
F.F.
B.O.
WINDOW 4'-0'
ABOVE
3RD
F.F.
T.O. 3RD F.F. 21'-2' A.F.F.
T.O. WINDOW T-0' ABOVE 2ND F.F.
B.O. WINDOW 4'-0' ABOVE 2ND F.F.
a.0. WINDOW 8'-6' A.F.F.
T.O. DOOR T-O' A.F.F.
_-VA
SCALE: 1/4'4-0'
WEST ELEVATION
EAST ELEVATION
ENVELOPE REQUIREMENTS PER 2015 IF -CC, WSEC AMENDMENTS
REFERENCE CHAPTER 51-11C WAC FOR ENVELOPE REQUIREMENTS. CONTRACTOR TO VERIFY ALL SUB
TRADES RECOGNIZE ALL REQUIREMENTS TO ACHIEVE ENVELOPE LEAKAGE MINIMUMS AS REGULATED BY
STATE CODE.
CAULK ALL SILL PLATES ON INTERIOR AND EXTERIOR SIDE OF PLATES TO ENSURE FULL BUILDING
LEAKAGE SEAL. CAULK ALL WDO'S / PENETRATIONS FOR AIR LEAKAGE SEAL.
INSTALL CLG GWB FIRST. CAULK SEAL GWB TO TOP PLATE OF ALL PARTITION WALLS WITH FIRE
RATED CAULK FOR 1-HOUR RATED CLG ASSEMBLY AND AIR LEAKAGE SEAL PRIOR TO ANY WALL GWB
INSTALLATION.
PROVIDE PUTTY PADS AT ALL EXTERIOR FACING ELEC. PENETRATIONS FOR PROPER AIR LEAKAGE SEAL.
PROVIDE PUTTY PADS AT ALL ELEC. PENETRATIONS THROUGH GWB CLG LID FOR PROPER AIR LEAKAGE
SEAL.
SEE SHEET A-0.1 FOR ADDITIONAL NOTES ON REQUIRED TESTING AND CODE REFERENCES. ENSURE
ALL PENETRATIONS, FENESTRATION, AIR INTAKES AND EXHAUST MEET ALL APPLICABLE CODES.
c
MASONRY NOTES:
1. THE MASON MUST PROVIDE A MIN. 4'-0' X 4'-0' MOCK UP OF
THE CMU WALL/ CULTURED STONE CAP,
AND GROUT LINES FOR THE ARCHITECT AND OWNERS
APPROVAL FOR COLOR SIZE AND SHAPE NO EXCEPTIONSIII
IF MASON FAILS TO PROVIDE MOCK UP FOR ARCHITECT
AND OWNERS APPROVAL PRIOR TO CONSTRUCTION THEY ARE
WORKING AT THEIR OWN RISK, AND WILL BE HELD RESPONSIBLE
FOR THEIR ACTIONS.
2. MASON MUST PROVIDE ARCHITECT WITH A COURSING PLAN FOR
CMU WALL AND CAP PRIOR TO CONSTRUCTION NO EXCEPTIONSIII
IF MASON FAILS TO PROVIDE COURSING PLAN FOR ARCHITECT AND
OWNERS APPROVAL PRIOR TO CONSTRUCTION THEY ARE WORKING
AT THEIR OWN RISK. AND WILL BE HELD RESPONSIBLE FOR THEIR
ACTIONS
3. CONTROL JOINTS TO BE INSTALLED BY MASONRY INSTITUTE CMU
MANUFACTURER. MASON TO COORDINATE ON CONTROL JOINT LOCATION
WITH ARCHITECT PRIOR TO CONSTRUCTION IF MASON FAILS TO
COORDINATE LOCATION WITH ARCHITECT AND OWNERS APPROVAL
PRIOR TO CONSTRUCTION THEY ARE WORKING AT THEIR OWN RISK,
AND WILL BE HELD RESPONSIBLE FOR THEIR ACTIONS
4. IT IS THE RESPONSIBLITY OF THE MASON TO SEAL ALL CMU/
CULTURED STONE W/ FOG COAT PER MANUFACTURER'S INSTRUCTIONS
W/ FABRISHIELD 653 0 CMU.
5. ALL CMU/ CULTURED STONE AND CAPS MUST BE CLEANED AND
APPROVED BY ARCHITECT/OWNER PRIOR TO SEALING NO EXCEPTIONSIII
IF MASON FAILS TO RECIEVE ARCHITECT AND OWNERS APPROVAL THEY
ARE WORKING AT THEIR OWN RISK. AND WILL BE HELD RESPONSIBLE
FOR THEIR ACTIONS
6. EXPANSION JOINTS TO BE INSTALLED BY MASONRY CONTRACTOR AS
REQUIRED BY THE MASONRY INSTITUTE & CMU MANUFACTURER
COORDINATE W/ ARCH.
7. ATTACH CMU WITH HOT DIPPED GALVANIZED, 2 PIECE WALL TIES,
TIE TO EXTERIOR WALL FRAMING. SUPPORT MAXIMUM 2 SQUARE FEET
OF AREA. TIE SHALL HAVE A HOOK ON THE EXTENDED LEG THAT
WILL ENGAGE OR ENCLOSE A HORIZONTAL JOINT REINFORCEMENT WIRE.
MANUFACTURER TO BE FERO'S 'RAP TIE' OR APPROVED SUBSTITUTION.
24 GA. VERT. METAL SIDING
T.O. PARAPET 42'-0' A.F.F.
B.O. WINDOW T-O' ABOVE 4TH F.F
24 GA. HORIZ. METAL SIDING
B.O. WINDOW 3'-0' ABOVE 4TH F.F.
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
B.O. WINDOW 7'-0' ABOVE 3RD F.F.
I
B.O. WINDOW 3'-0' ABOVE 3RD F.F.
T.O. 3RD F.F. 21'-2' A.F.F.
B.O. WINDOW 7'-0' ABOVE 2ND F.F.
VINYL WINDOWS TYP.
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
P-TAC UNIT TYP. AT UNITS
T.O. 2ND F.F. W-3-3/4' A.F.F. 19,
BEAM PER STRUCT/ WRAP W/ CEDAR
8 X 8 WOOD COLUMN PER STUCTURAL
PRIME. PNT. TYP.
24 X 24 CONCRETE PLYNTH
W/ MOO LINER PANEL FOR
SMOOTH ARCHITECTURAL FINISH
CHAMFER ALL EDGES TYP.
SCALE: 1/4'4-0'
TRII
B.O. WINDOW T-0' ABOVE 4TH F.F. is
B.O. WINDOW 3'-0' ABOVE 4TH F.F.
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
B.O. WINDOW T-O' ABOVE 3RD F.F.
B.O. WINDOW 3'-0' ABOVE 3RD F.F.
T.O. 3RD F.F. 21'-2' A.F.F.
B.O. WINDOW 7'-0' ABOVE 2ND F.F.
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
T.O. 2ND F.F. 11'-3-3/4' A.F.F. Al
6'-0' TAL� DECORATIVE
ORNAMEN AL BLACK MTL. FENCING
T^ ICI% CI ^^n n. A•
SCALE: 1/4'4-0'
MATERIAL SCHEDULE
MATERIAL:
MANUFACTURER:
COLOR:
HMF/ HMD EXTERIOR PAINT COLORS
PAINT #1
1 BENJAMIN MOORE
TBD
METAL HR 36 HORIZONTAL SIDING
METAL #1
AEP SPAN
JTBD
METAL HR 36 VERTICAL SIDING
METAL #2
JAEP SPAN
TBD
METAL MINI V RIB SIDING
METAL #3
AEP SPAN
TBD
CONCRETE MASONRY UNIT
CMU #1
MUTUAL MATERIALS
I GROUND FACED - COLOR TBD
DOWNSPOUT/ GUTTERS
METAL #2
1 AEP SPAN
ICOLOR TBD
COLORED CONCRETE
CONC. COLOR #1
1 DAVIS COLORS
ADOBE
SOFFITS
EXT. GWB
SAND PEPPLE FINE
STUCCO FINISH COAT COLOR TBD
ALUMINUM STOREFRONT WINDOW SYSTEMS (INSULATED -THERMALLY BROKEN)
ANODIZED
I ARCADIA
JTBD
GLAZING 1 INCH) ANNEALED GLASS)
CLEAR + CLEAR
PPG
SOLARBAN 60 CLEAR LOW E AS REQ'D TO MEET .39 UV AND .40 SC
METAL PARAPET CAP
METAL #1
JAEP SPAN
JTBD
ORNAMENTAL FENCE
TBD
IBLACK
WINDOWS
TBD
I COLOR TBD
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
6429
EG STERED
HITECT
STATE
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
�rA
ABER
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
PRELIM SET 5-21-19
6/14/19 PERMIT SUBMITTAL
�8/27/19 PERMIT REVISIONS
SHEET TITLE:
ELEVATIONS
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A��j
0
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
E
r;
R
G;
� O O
A-4.1
F
U
COVERED PARKING
BUILDING SECTION 'A'
UNIT
NUNIT
HOUSEKEEPING
ELEV. EQUIP.
HALL
EC PT ON �
o
�UNIT
Q
IT
A
2-HOUR SHAFT —
TYP. AT ALL
STAIRWELLS TO
UNDERSIDE
OF ROOF DECK
C
IT
C
ELECTRICAL
T.O. PARAPET 42'-0' A.F.F.
T.O. SHEATHING 40'-7' A.F.F.
T.O. WINDOW T-O' ABOVE 4TH F.F.
B.O. WINDOW 4'-0' ABOVE 4TH F.F.
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
T.O. WINDOW 7'-0' ABOVE 3RD F.F.
B.O. WINDOW 4'-0' ABOVE 3RD F.F.
T.O. 3RD F.F. 21'-2' A.F.F.
T.O. WINDOW T-O' ABOVE 2ND F.F.
B.O. WINDOW 4'-0' ABOVE 2ND F.F.
T.O. 2ND F.F. W-3-3/4' A.F.F.
T.O. FINISHED FLOOR 0'-0'
SCALE: 1/4'=1'-O'
CAA RLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
642s
EG STERED
HITECT
STATE
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
M[3FJ�
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
PRELIM SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECTIONS
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A — oO
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
EO
G 0 H
I--- -
T.O. PARAPET 42'-0' A.F.F.
T.O. SHEATHING 40'-7' A.F.F.
T.O. WINDOW 7'-0' ABOVE 4TH F.F.
B.O. WINDOW 1'-6' ABOVE 4TH F.F.
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
2
OPP.
1/4' PER\12' ROOF SLOPE
I
C NFERENCE ROOM
T.O.
WINDOW 7'-0' ABOVE
3RD
F.F.
_
� I
B.O.
WINDOW 3'-0' ABOVE
31RD
F.F.
BRE KROOM
T.O. 3RD F.F. 21'-2' A.F.F.
_1 1
T.O. WINDOW 7'-0' ABOVE 2ND F.F. _
HOUSE-
B.O. B.O. WINDOW 3'-0' ABOVE 2ND F.F.
T.O.
II cc
T.O. FINISHED PLO, )R 0'4
HOUSEKEEPING
ELEV.
EQUIP.
cV
2-HOUR SHAFT.
TYP. AT ELIEVA
O a
I -
0 FICE REST
ROOM
ELEVATOR
,.
i' L
1 �
-� ---------------�--
BUILDING SECTION 'B"
HALL
HALL
HALL
1/4' PER 12' ROOF SLOPE
2-HOUR SHAFT
TYP. AT STAIRS
AND VENT
STAIR
k:
T.O. PARAPET 42'-0' A.F.F.
T.O. SHEATHING 40'-7' A.F.F.
T.O. WINDOW 1'-5' ABOVE 4TH F.F.
T.O. 4TH F.F. 31'-0-1/4' A.F.F.
B.O. WINDOW 8'-0' ABOVE 3RD F.F.
T.O. LANDING 5'-0' ABOVE 3RD F.F.
T.O. WINDOW 1'-5' ABOVE 3RD F.F.
T.O. 3RD F.F. 21'-2' A.F.F.
B.O. WINDOW T-11' ABOVE 2ND F.F.
T.O. LANDING 4'-11' ABOVE 2ND F.F. o.
T.O. WINDOW 0'-8' ABOVE 2ND F.F.
T.O. 2ND F.F. 11'-3-3/4' A.F.F.
B.O. WINDOW 8'-8' A.F.F.
T.O. LANDING 5'-8' A.F.F.
- - -v I. - I T.O. FINISHED FLOOR 0'-0'
SCALE: 1/4'=1'-O'
C'ARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
642s
EG STERED
HITECT
STATE
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
rmrER
CONSTRUCTION
360.354.3500
19-312
REVISIONS
PRELIM SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECTIONS
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A - - I
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S
BUILDING SECTION 'C'
ET 42'-0' A.F.F.
HING 40'-7' A.F.F.
F. 31'-0-1/4' A.F.F.
F. 21'-2' A.F.F.
F. 11'-3-3/4' A.F.F.
ED FLOOR 0'-0'
SCALE: 1/4'=1'-O'
CAA RLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
6429
STATE
TERED
ITECT
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
M[3FJ�
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
PRELIM SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECTIONS
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
BUILDING SECTION 'D'
C'ARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
6429 EG STERED
HITECT
STATE
SALISH INN
907 30TH STREET
� ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
rER
aNsrnoN
� 360.354.3500
SCALE: 1/4'=1'-O'
19-312
REVISIONS
PRELIM SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECTIONS
Pic
PROJECT ARCHITECT:
Pic
DRAWN BY:
Pic
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A o j
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
BUILDING SECTION 'E"
i0 C�PRLETTI ARCHITECTS P.S.
architecture, planning, interior design
)P.
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
SCALE: 1/4'=1'-O'
6429
STATE
TERED
ITECT
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
WFJ�
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
PRELIM. SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECTIONS
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
ob T.O. WINDOW 8'-0' A.F.
IF
T.O. FINISHED FLOOR
BUILDING SECTION 'F"
ET 42'-0' A.F.F.
HING 40'-7' A.F.F.
r'-O' ABOVE 4TH F.F.
F. 31'-0-1/4' A.F.F.
14,
7'-0' ABOVE 3RD F.F
21'-2' A.F.F.
7'-0' ABOVE 2ND F.F.
F. W-3-3/4' A.F.F.
ED FLOOR 0'-0' Ah
i
SCALE: 1/4'=1'-O'
C'ARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: NO
0� 424-0394
Fax: 424-5726
642s
EG STERED
HITECT
STATE
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
rmrER
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
PRELIM. SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
SECTIONS
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
A - .5
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
TYP. ROOF CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
T.O. PARAPET CAP 42'-0' A.F.F.
MY SHT. METAL PARAPET CAP
9 7/10
A-6.4
jh T.O. ROOF SHEATHING 40'-7' A.F.F.
RIM JOIST PER STRUCTURAL
HEADER PER STRUCTURAL
T.O. WINDOW T-O' ABOVE 2ND F.F.
SHT. MTL. DRIP EDGE
1w
In
VINYL WINDOW
SHT. MTL. DRIP EDGE
B.O. WINDOW 1'-6' ABOVE 2ND F.F.
IRV
12
-6.
T.O. FOURTH FLOOR 31'-0-1/4' A.F.F.
RIM JOIST PER STRUCTURAL
GRID
SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F
TYP. FLOOR CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
SLOPE RIM JOIST PER STRUCTURAL
T.O. THIRD FLOOR 21'-2' A.F.F.
mv
TYP. WALL CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. DRIP EDGE
T.O. WINDOW T-O' ABOVE 2ND F.F.
ACP CEILING I IV
HEADER PER STRUCTURAL
GWB JAMB/
HEAD
WINDOW
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
IV
SHT. MTL. DRIP EDGE
1 X 4 WD SILL TYP. FLOOR CONSTRUCTION
RIP AS REQ'D. (11 HOUR RATED TYPICAL
PRIME & PAINT SEE 1/A-5.0
1 X 4 APRON
PRIME & PAINT
HEADER PER STRUCTURAL
T.O. WINDOW T-O' ABOVE 2ND F.F.
ACP CEILING
SHT. MTL. DRIP EDGEIF
F-HEAD
GWB JAMB/
VINYL WINDOW
11 1 X 4 WD SILL
RIP AS REQ'D.
SHT. MTL. DRIP EDGE PRIME & PAINT
B.O. WINDOW 3'-0' ABOVE 2ND F.F. 1 X 4 APRON
PRIME & PAINT
TYP. FLOOR CONSTRUQjj0hLI
AL
111 HOUR RATED TYPIC
SEE 1/A-5.0
RIM JOIST PER STRUCTURAL -
T.O. THIRD FLOOR 21'-2' A.F.F.
TYP. WALL CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. DRIP EDGE Dr:::\��-HEAD
T.O. WINDOW 7'-0' ABOVE 2ND F.F.
mv ACP CEILING
HEADER PER STRUCTURAL GWB JAMB/
DOW
--�TYPICALxWALL SECTION
CONTINUED
SCALE: 3/4'=1'-O'
T.O. SECOND FINISHED FLOOR 11'-3-3/4' A.F.F.
BLOCKING PER STRUCTURAL
SHI. MIL. DRIP EDGE
1X4WDSILL
RIP AS REQ'D.
PRIME & PAINT
1 X 4 APRON
PRIME & PAINT
ACP CEILING
GWB JAMB/
HEAD
1 X 4 WD SILL
RIP AS REQ'D.
PRIME & PAINT
1 X 4 APRON
CLR. LAQ.
I PRIME & PAINT
2' CONT. STRIP VENT
METAL SIDING
SHT. MTL. DRIP EDGE
SHT. MTL. DRIP EDGE
CULTURED STONE CAP / 13
A-6
TYP. WALL CONSTRUCTION
(11 HOUR RATED TYPICAL
GROUND FACE CMU-VENEER 0/
V AIR SPACE 0/ 60 MIN. B.P. 0/
TYVEK BUILDING WRAP 0/
SHEATHING 0/
2 X 6 FRAMING 0 16' O.C. W/
R-21 BATT INSULATION W/
VAPOR BARRIER WARM SIDE
W/ 5/8' GWB INTERIOR FACE
TAPE. MUD, SAND. PRIME. PNT
T.O. CMU VENEER BEYOND/ ' A.F.F.
ANCHOR BOLT PER
;STRUCTURAL
B.O. WINDOW 3'-0' A.F.F.
>. X 6 P.T. SILL PLATE
NERVESTRAL FLASHING/ WEEPS
EA GRAVEL
SLAB EDGE INSULA /IO��—
T.O. FINISHED FLOOR -
FINISHED GRADE
SLOPE Ys':1'-O' — — — — —
6' PVC TIGHT LINE FOR I I —I I MI I I —I I MI I I —I I M
DOWN SPOUTS SEE CIVIL I-� I I I -I I I —I I I —I I I —I I I-
DWGS FOR LOCATION TYP. III=I I=I I I -I I I —I
4' PVC PERFERORATED =I I I —I I (-
FOOTING DRAIN TOAPPROVED OUTFLOW WRAP 1—
I I I I=I I I=I
WITH FILTER FABRIC AND —
FREE DRAIN MATERIAL. I— —
CONC. FOOTING/ STEM
WALL PER STRUCTURAL —,-
TYPICAL. WALL SECTION
RID
d m.
TYP. ROOF CONSTRUCTION
(1) HOUR RATED TYPICAL
60 MIL TPO ROOFING 0/
R-38 RIGID INSULATION 0/
6 MIL VAPOR BARRIER 0/
J' DENSDECK 0/
3/4' SHEATHING 0/
11-7/8' TJI ROOF JOISTS 6 24' O.C.
W/ 7/8' HAT CHANNEL
W/ 5/8' GWB. TAPE. MUD, SAND,
PRIME, PNT. TYP. LEVEL 4 FINISH
T.O. PARAPET CAP 42'-0' A.F.F.
SHT. TAL PARAPET CAP
7/10
A-6.4
T.O. ROOF SHEATHING 40'-7' A.F.F.
I' I -.,—RIM JOIST PER STRUCTURAL
-HEADER PER STRUCTURAL
T.O. WINDOW T-O' ABOVE 2ND F.F.
-SHT. MTL. DRIP EDGE
16
A-6.2
VINYL WINDOW
-SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
12
-6.
T.O. FOURTH FLOOR 31'-0-1/4' A.F.F.
—RIM JOIST PER STRUCTURAL
—SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
CARLETTI ARCbITECTS P.S.
- TYP. FLOOR CONSTRUCTION
architecture, planning, interior design
(11 HOUR RATED TYPICAL
1' GYP CRETE 0/
116 EAST FIR STREET
3/4' SHEATHING 0/
SUITE A
14' TJI FLOOR JOISTS 0 16' O.C.
W/ R-49 BATT INSULATION TO FILL
MOUNT VERNON, WA. 98273
VOID W/ 7/8' HAT CHANNEL
W/ 5/8' GWB, TAPE. MUD. SAND,
Phone: 0� 424-0394
PRIME. PNT. TYP. LEVEL 4 FINISH
Fax: 424-5726
RO
-RIM JOIST PER STRUCTURAL
T.O. THIRD FLOOR 21'-2' A.F.F.
_ TYP. WALL CONSTRUCTION
9
(11 HOUR RATED TYPICAL
EG STERED
24 GA. MTL. WALL PANLES 0/
HITECT
TYVEK COMMERCIAL BUILDING WRAP 0/
7PETERO
SHEATHING 0/
2 X 6 FRAMING 0 16' O.C. W/
TTIR-21
BATT INSULATION W/
STATE WASHING TON
VAPOR BARRIER WARM SIDE 0/
W/ 5/8' GWB INTERIOR FACE
TAPE. MUD. SAND. PRIME. PNT.
LEVEL 4 FINISH
-SHT. MTL. DRIP EDGE
T.O. WINDOW T-O' ABOVE 2ND F.F.
SAL I S H I N N
907 30TH STREET
- HEADER PER STRUCTURAL
ANACORTES, WA 98221
WINDOW
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
B.O. WINDOW 3'-0' ABOVE 2ND F.F. PHONE: 360-770-3701
-SHT. MTL. DRIP EDGE
- TYP. FLOOR CONSTRUCTION r
(11 HOUR RATED TYPICAL
1' GYP CRETE 0/ B E R
3/4' SHEATHING 0/ CONSTRUCTION
14' TJI FLOOR JOISTS 0 16' O.C. 360.354.3500
W/ R-49 BATT INSULATION TO FILL
VOID W/ 7/8' HAT CHANNEL
W/ 5/8' EXTERIOR GWB W/
STUCCO FINISH COAT
T.O. SECOND FINISHED FLOOR 11'-3-3/4' A.F.F. 19-312
BEAM PER STRUCTURAL
REVISIONS:
I — BLOCKING PER STRUCTURAL
SHT. MTL. DRIP EDGE PRELIM. SET 5-21-19
7/8' HAT CHANNEL W/
5/8' GWB W/ STUCCO FINISH COAT 6/14/19 PERMIT SUBMITTAL
HEADER PER STRUCTURAL BEAM PER STRUCTURAL
T.O. WINDOW 7'-0' ABOVE 2ND F.F. WRAP W/ 5/8' GWB 8/27/19 PERMIT REVISIONS
ACP CEILING SHT. MTL. DRIP EDGE METAL WALL PANELS
"-HEADER PER SHT. MTL. DRIP EDGE
STRUCTURAL
GWB JAMB/ 2' CONT. STRIP VENT
HEAD
—ALUMINUM VINYL WINDOW SHT. MTL. CORNER TRIM
STOREFRONT
WINDOW SYSTEM METAL WALL PANELS BEYOND
SHEET TITLE:
SHT. MTL. DRIP EDGE
19 B.O. WINDOW 3'-0' ABOVE 2ND F.F. CULTURED STONE CAP TYP. WALL SECTIONS
L— TYP. FLOOR CONSTRUCTION
� 1 X 4WD SILL (1) HOUR RATED TYPICAL
T.O. CMU VENEER 4'-0' A.F.F.
RIP AS REQ'D,PRIME & PAIN j I 1' GYP CRETE 0/
1 X 4 APRON PRIME & PAIN I 3/4' SHEATHING 0/
14' TJI FLOOR JOISTS 0 16' O.C.
W/ R-49 BATT INSULATION TO FILL
TYP. SLAB CONSTRUCTION VOID W/ 7/8' HAT CHANNEL
4' SLAB ON GRADE W/ W/ 5/8' GWB. TAPE, MUD, SAND.
#4 BAR 0 18' O.C. EA. WAY PRIME, PNT. TYP. LEVEL 4 FINISH
PER STRUCTURAL 0/
15 MIL VAPOR BARRIER I RIM JOIST PER STRUCTURAL
0/ 6' CAPILARY BREAK I CMU VENEER BEYOND
PER GEO - TECH REPORT I T.O. THIRD FLOOR 21'-2' A.F.F.
0/ COMPACTED TYP. WALL CONSTRUCTION F-
STRUCTURAL FILL (1) HOUR RATED TYPICAL
Ir 24 GA. MTL. WALL PANLES 0/ ASPHALT PARKING GARAGE SURFACE
TYVEK COMMERCIAL BUILDING WRAP 0/ PJC
A-6.3 SHEATHING 0/ PER CIVIL ENINGEER PROJECT ARCHITECT:
2 X 6 FRAMING 0 16' O.C. W/ T.O. FINISHED FLOOR 0'-0'
R-21 BATT INSULATION W/ PJC
-----------------4------ VAPOR BARRIER WARM SIDE 0/ DRAWN BY:
W/ 5/8' GWB INTERIOR FACE ' PJC
TAPE. MUD. SAND. PRIME. PNT.
_ I I I I IIII I LEVEL 4 FINISH i 6' PVC TIGHT LINE FOR CHECKED BY:
IIIIIIIII—III SHT. MTL. DRIP EDGE i DOWN SPOUTS SEE CIVIL
I=III=III=III=III=I I = I T.O. WINDOW 7'-0' ABOVE 2ND F.F. i DWGS FOR LOCATION TYP.
EI I I=I I I=I I I=I I I=I I I=I 11- 4' PVC PERFERORATED DAT 08/19
i
-I I I -I I I -I I I -I I I —I I I- H
ADER PER STRUCTURAL i FOOTING DRAIN TO 19-312.DWG
III=I I I=I I I=I I I=I I �- i APPROVED OUTFLOW WRAP
I I I=I I I=I I I=I I i ---------------------- WITH FILTER FABRIC AND COMPUTER FILE NAME
I I MI I I —I I MI I I FREE DRAIN MATERIAL.
I I I=I I I l � l WINDOW
;IIIIIII5oo
TYPICAL WALL. SECTION TYPICAL. WALL SECTION
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
CONTINUE1)SCALE: 3/4'=1'-O' SCALE: 3/4'=1'-O' SCALE: 3/4'=1'-O'
�IiQ•i
GWB JAMB/
HEAD
1 X 4 WD SILL
RIP AS REQ'D.
PRIME & PNT.
1 X 4 APRONI
PRIME & PNT.
GWB JAMB/
HEAD
1X4WDSILL
RIP AS REQ'D.
PRIME & PNT.
1 X 4 APRON —
PRIME & PNT.
X 4 WD SILL
GRID RIP AS REQ'D.
PRIME & PNT.
TYP. ROOF CONSTRUCTION 1 X 4 APRON—
(11 HOUR RATED TYPICAL PRIME & PNT.
SEE 1/A-5.0
T.O. PARAPET CAP 42'-0' A.F.F.
META DRIP EDGE
12
A-6.3
T.O. ROOF SHEATHING 40'-7' A.F.F.
6' MTL. BOX GUTTER
2 X 4 P.T. NAILER
RIM JOIST PER STRUCTURAL
HEADER PER STRUCTURAL
T.O. WINDOW 7'-0' ABOVE 2ND F.F.
SHT. MTL. DRIP EDGE
GWB JAMB/
16 HEAD
WINDOW
I �
1 X 4 WD SILL
RIP AS REQ'D.
PRIME & PNT.
SHT. MTL. DRIP EDGE 1 X 4 APRON—
PRIME8.0. WINDOW 9'-0' ABOVE 2ND F.F. &PNT.
12
T.O. FOURTH FLOOR 31'-0-1/4' A.F.F.
—RIM JOIST PER STRUCTURAL
HEADER PER STRUCTURAL
T.O. WINDOW 7'-O' ABOVE 2ND F.F.
SHT. MTL. DRIP EDGE
WINDOW
`SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
TYP. FLOOR CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
—RIM JOIST PER STRUCTURAL
T.O. THIRD FLOOR 21'-2' A.F.F.
TYP. WALL CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. DRIP EDGE
T.O. WINDOW 7'-O' ABOVE 2ND F.F.
HEADER PER STRUCTURAL
GWB JAMB/
HEAD
WINDOW
TYPICAL WALL SECTION
II
13
-6.
GWB JAMB/
HEAD
—SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
- TYP. FLOOR CONSTRUCTIO
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
RIM JOIST PER STRUCTURAL
T.O. THIRD FLOOR 21'-2' A.F.F.
TYP. WALL CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. DRIP EDGE
T.O. WINDOW T-O' ABOVE 2ND F.F.
— HEADER PER STRUCTURAL
— WINDOW
i B.O. WINDOW 3'-0' ABOVE 2ND F.F.
— SHT. MTL. DRIP EDGE
- TYP. FLOOR CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
T.O. SECOND FINISHED FLOOR W-3-3/4' A.F.F.
--� BEAM PER STRUCTURAL
—BLOCKING PER STRUCTURAL
—SHT. MTL. DRIP EDGE
— METAL SIDING
— HEADER PER STRUCTURAL
T.O. WINDOW 8'-0' A.F.F.
SHT. MTL. DRIP EDGE
ALUMINUM STOREFRONT
WINDOW SYSTEM
—CULTURED STONE CAP BEYOND
T.O. CMU VENEER 4'-0' A.F.F.
TYP. SLAB CONSTRUCTION
SEE 2/A-5.0
CMU VENEER BEYOND
15 SLAB EDGE INSULATION
A-6.2 SHT. METAL FLASHING TYP.
CULTURED STONE CAP
CMU VENEER
T.O. FINISHED FLOOR 0'-0' AK
------ s=--_ --- ' FINISHED GRADE
SLOPE Ye':1'-O'
I
z i _ III i i iI I I
I i i41—qI1= I I=III=1 i i LINE FOR
—III—I —I —I I —I I I 4MI1SEE CIVIL
I= I—I11OCATION TYP.
I Ed I —I I El —I I I— —I I — PERFERORATED
—I � I —I � I —III— '' III- I I 7�=OV�
DRAIN TO
11—I I I —I I IED OUTFLOW WRAP
—I I I —I I I —I I I I I=I I ITH FILTER FABRIC AND
—I I —I __,o\�_ 4 I=_—IFREE DRAIN MATERIAL.
—I 11=1 I I —I I I III ,; I
CONC. FOOTING/ STEM
— —IIII I I=I I I —I I I=I I I —I I I —I 15 WALL PER STRUCTURAL
TYPICAL WALL SECTION
GRID
TYP. ROOF CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
T.O. PARAPET CAP 42'-0' A.F.F.
SHT. METAL PARAPET CAP
7/10
A-6.4
T.O. ROOF SHEATHING 40'-7' A.F.F.
RIM JOIST PER STRUCTURAL
HEADER PER STRUCTURAL
T.O. WINDOW 7'-0' ABOVE 2ND F.F.
SHT. MTL. DRIP EDGE
16
A-6.2
WINDOW
SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
12
A-6.2
T.O. FOURTH FLOOR 31'-0-1/4' A.F.F.
RIM JOIST PER STRUCTURAL
HEADER PER STRUCTURAL
,` T.O. WINDOW 7'-O' ABOVE 2ND F.F.
SHT. MTL. DRIP EDGE
WINDOW
SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
TYP. FLOOR CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
RIM JOIST PER STRUCTURAL
T.O. THIRD FLOOR 21'-2' A.F.F.
TYP. WALL CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
GWB JAMB/
HEAD
TYP. ROOF CONSTRUCTION -----\
(1) HOUR RATED TYPICAL
1 X 4 WD SILL
60 MIL TPO ROOFING 0/
RIP AS REQ'D.
TAPERED INSULATION 0/
PRIME & PNT.
R-38 RIGID INSULATION 0/
1/4' DENSDECK 0/
1 X 4 APRON
6 MIL VAPOR BARRIER 0/
= PRIME &PNT.
3/4' SHEATHING 0/
14' TJI ROOF JOISTS 0 24' O.C.
W/ 7/8' HAT CHANNEL
W/ 5/8' GWB. TAPE. MUD, SAND,
PRIME. PNT. TYP.
T.O. PARAPET CAP 12'-8' A.F.F.
SHT. METAL PARAPET CAP
ROOF DRAIN/ OVERFLOW PER
ROOF PLAN
jA T.O. SECOND FINISHED
FLOOR 11'-3-3/4' A.F.F.
METAL SIDING
BEAM PER STRUCTURAL
4
BLOCKING PER STRUCTURAL
SHT. MTL. DRIP EDGE
7/8' HAT CHANNEL W/ —
5/8' GWB W/ STUCCO FINISH COA
SHT. MTL. DRIP EDGE
T.O. WINDOW 7'-O' ABOVE 2ND F.F.
HEADER PER STRUCTURAL
WINDOW
TYPICAL WALL SECTION
GWB JAMB/
HEAD
1 X 4 WD SILL
RIP AS REQ'D.
CLR. LAQ.
1 X 4 APRON
CLR. LAQ.
IC 0 N T I N U E D SCALE: 3/4'=1'-0' � I J SCALE: 3/4'=1'-0' CONTINUED SCALE: 3/4'=1'-0'
METAL SIDING
SHT. MTL. DRIP EDGE
SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
TYP. FLOOR CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
RIM JOIST PER STRUCTURAL -
T.O. THIRD FLOOR 21'-2' A.F.F.
TYP. WALL CONSTRUCTION —
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. DRIP EDGE
T.O. WINDOW T-O' ABOVE 2ND F.F.
HEADER PER STRUCTURAL
WINDOW
TYP. FLOOR CONSTRUCTION
(11 HOUR RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. DRIP EDGE
B.O. WINDOW 3'-0' ABOVE 2ND F.F.
SHEET MTL. REGLET/
SNAP LOCK FLASHING
\ RUN TPO UNDER SNAP LOCK
LASHING MINIMUM 6'
w
2'-0'
`—HEADER PER
STRUCTURAL
13 GWB JAMB/
HEAD
-6.2
ALUMINUM
STOREFRONT
WINDOW
SYSTEM
TYP. SLAB CONSTRUCTION
SEE 2/A-5.0
�T T
.Y t•t .
------------------
WALL PER STRUCTURALI—
IIIi
TYPICAL WALL SECTION
3
1 X 4 WD SILL
RIP AS REQ'D.
CLR. LAQ.
1 X 4 APRON
CLR. LAQ.
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: RO
0� 424-0394
Fax: 424-5726
6429
EG STERED
HITECT
STATE
SALISH INN
GWB JAMB/ 907 30TH STREET
HEAD ANACORTES, WA 98221
EK TERA ASARA, LLC
1 X 4 WD SILL
905 20TH STREET
RIP AS REQ'D,
CLR. LAQ.
ANACORTES, WA 98211
1 X 4 APRON
CONTACT: KULJIT SHOKER
CLR. LAQ.
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
15
A-6.3
E R-1
trAAB
CONSTRUCTION
360.354.3500
-- — 19-312
REVISIONS:
4'-0' PRELIM. SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SHEET TITLE:
TYP. WALL SECTIONS
Pic
PROJECT ARCHITECT:
Pic
DRAWN BY:
Pic
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
SCALE: 3/4'=1'-O'
GRID
GWB JAMB/
HEAD
GWB JAMB/
HEAD
GWB JAMB/
HEAD
5
BLOCKING PER STRUCTURAL
METAL SIDING
HEADER PER STRUCTURAL
SHT. MTL. DRIP EDGE
18
A-6.3
VINYL SLIDER
DOOR
SHT_-MTL. FLASHING SET
IN CONT. BED OF SEALANT
PT 2 X 6 LEDGER ATTACH'
PER STRUCTURAL
JOIST -HANGER"' O.C.
DECK SLOPE
1/8':1'-O'
MET
TYP. ROOF CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
T.O. PARAPET CAP 42'-0' A.F.F.
META DRIP EDGE
12
A-6.3
T.O. ROOF SHEATHING 40'-7' A.F.F.
6' MTL. BOX GUTTER
2 X 4 P.T. NAILER
MTL. SIDING
BEAM PER STRUCTURAL
SHT. MTL. DRIP EDGE
T.O. DOOR 7'-0' ABOVE 2ND F.F.
7/8' HAT CHANNEL W/
5/8' GWB W/ STUCCO FINISH COAT
DARK BRONZE ANODIZED
ALUMINUM GUARDRAIL
SYSTEM 42' A.F.F.
EPDXY WATERPROOF
DECK SYSTEM 0/
1-1/8' PLYWOOD 0/
2 X 6 PT JOISTS 0 16' O.C.
BLOCKING PER STRUCTURAL
W/ H2.5 JOIST TO BEAM
T.O. FOURTH FLOOR 31'-0-1/4' A.F.F.
DOUBLE PT 2 X 10 RIM BOARDS PER
STRUCTURAL
tT PT BEAM PER STRUCTURAL
POCKET IN WALL FRAMING
16
A-6.3
I T.O. DOOR 7'-0' ABOVE 2ND F.F.
—SHT. MTL. DRIP EDGE
SLIDER
DOOR
TYP. FLOOR CONSTRUCTION
"OUR -RATED TYPICAL
SEE 1/A-5.0
SHT. MTL. FLASHING SET
IN CONT. BED OF SEALANT
PT 2 X 6 LEDGER ATTACH'
PER STRUCTURAL W/
liv:l-v
-RIM JOIST PER STRUCTURAL
TYP. WALL CONSTRUCTION
METAL -SIDING
HEADER PER STRUCTURAL
4.1
TYPICAL WALL SECTION
DARK BRONZE ANODIZED
ALUMINUM GUARDRAIL
SYSTEM 42' A.F.F.
EPDXY WATERPROOF
DECK SYSTEM 0/
1-1/8' PLYWOOD 0/
2 X 6 PT JOISTS 0 16' O.C.
BLOCKING PER STRUCTURAL
W/ H2.5 JOIST TO BEAM
T.O. THIRD FLOOR 21'-2' A.F.F.
-DOUBLE PT 2 X 10 RIM BOARDS PER
STRUCTURAL
- PT BEAM PER STRUCTURAL
POCKET IN WALL FRAMING
T.O. DOOR T-O' ABOVE 2ND F.F.
GWB JAMB/
HEAD
5
-SEE 1/A-5.0
SHT. MTL. FLASHING SET
It"ONT. BED OF SEALAt
PT 2 X 6 LEDGER ATTAC
PER STRUCTURAL W/
I�nT 1 1 •I��nn .'.^ —
-- RIM JOIST PER STRUCTURAL
TYP. WALL CONSTRUCTION
(11 HOUR RACTED TYPICAL
SEE 1/A-5.0
TYPICAL
METAL
J..;,
SHT. MTL. FLASHING SET
IN CONT. BED OF SEALANT
Y9 19 LEDGER -ATTACH'
PER STRUCTURAL W/
JOIST HANGERS 16' O.C.
BEAM PER STRUCTURAL
10
-6.3
I-
'�
WALL SECTION
DARK BRONZE ANODIZED
ALUMINUM GUARDRAIL
SYSTEM 42' A.F.F.
EPDXY WATERPROOF
DECK SYSTEM 0/
1-1/8' PLYWOOD 0/
2 X 6 PT JOISTS 0 16' O.C.
BLOCKING PER STRUCTURAL
W/ H2.5 JOIST TO BEAM
T.O. THIRD FLOOR 21'-2' A.F.F.
DOUBLE PT 2 X 10 RIM BOARDS PER
STRUCTURAL
PT BEAM PER STRUCTURAL
POCKET IN WALL FRAMING
T.O. DOOR T-0' ABOVE 2ND F.F.
DARK BRONZE ANODIZED
ALUMINUM GUARDRAIL
SYSTEM 42' A.F.F.
EPDXY WATERPROOF
DECK SYSTEM 0/
1-1/8' PLYWOOD 0/
2 X 12 JOISTS 0 16' O.C.
RIP TOP FOR SLOPE AS
REO'D W/ SPRAY INSULATION
FOR R-38 VALUE
W/ 7/8' HAT CHANNEL W/
5/8' GWB, TAPE. MUD. PRIME. PNT. TYP.
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: RO
0� 424-0394
Fax: 424-5726
6429
EG STERED
HITECT
STATE
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
rMA ER
�B
CONSTRUCTION
360.354.3500
T.O. SECOND FINISHED FLOOR W-3-3/4' A.F.F.
SHT. MTL. DRIP EDGE 19-312
2 X 10 RIM BOARDS PER
STRUCTURAL
REVISIONS:
-SHT. MTL. DRIP EDGE
PRELIM. SET 5-21-19
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
-SHT. MTL. DRIP EDGE SHEET TITLE:
-CULTURED STONE CAP
TYP. WALL SECTIONS
T.O. CMU VENEER 4'-0' A.F.F.
-TYP. WALL CONSTRUCTION
(1) HOUR RATED TYPICAL
SEE 1/A-5.0
- TYP. SLAB CONSTRUCTION
SEE 2/A-5.0
ANCHOR BOLT PER
STRUCTURAL
r-- 2 X 6 P.T. SILL PLATE
SLAB EDGE INSULATION
NERVESTRAL FLASHING/ WEEPS
PEE GRAVEL
CMU VENEER PJC
T.O. FINISHED FLOOR 0'-0' PROJECT ARCHITECT:
FINISHED GRADE PJC
SLOPE Y':1'-0' DRAWN BY:
I —III —I —
I I owt ftli r::W0I IFOR
III=1 I I=1 Door: CIVIL PH CHECKED BY:
III= I=I IIII f- `T 0 LOCATION TYP.
C PERFERORATED 02/08/19
OTING DRAIN TO DATE
III=I - PROVED OUTFLOW WRAP
I -I I H FILTER FABRIC AND 19-312.DWG
-I I I— FREE DRAIN MATERIAL. COMPUTER FILE NAME
CONC. FOOTING/ STEM
WALL PER STRUCTURALA - 52
0
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
CONTINUED
SCALE: 3/4'=1'-O'
SCALE: 3/4'4-0'
5'-0'
SECTION 1011 STAIRWAY NOTES:
SECTION 1014 HANDRAIL NOTES:
SECTION 1015 GUARDRAIL NOTES:
1. STAIRWAY WIDTH TO BE NO LESS THAN 44' CLEAR UNLESS
1.
HANDRAIL HEIGHT MEASURED ABOVE STAIR TREAD NOSING.
1.
PROVIDE GUARDRAIL MIN. 42' ABOVE NOSE OF TREAD/LAND LLNN�? TANDPIPE COORD.
SERVING AN OCCUPANT LOAD OF LESS THAN 50 OCCUPANTS.
OR FINISH SURFACE OF RAMP SLOPE. SHALL BE UNIFORM.
FOR ALL HEIGHTS 30' A.F.F. OR GREATER TYP. CLEARANCE REQ'S W/
THEN REQUIRED WIDTH IS 36'
NOT LESS THAN 34 INCHES AND NOT MORE THAT 38
2.
MAX. SPHERE OPENING TO BE 4' BETWEEN MEMBERS UP TO A FIRE MARSHALL
2. MIN. CLEAR HEAD HEIGHT ABOVE ANY TREAD NOSING IS 6'-8'.
INCHES.
HEIGHT OF 36'. OPENING CAN BE 4 3/8' FROM 36' TO 42'.
3. MAXIMUM RISER HEIGHT 7'. TREAD WIDTH 11'. RISERS TO BE
2.
HANDRAIL- GRIPPING SURFACE SHALL BE CONTINUOUS.
3.
THE TRIANGULAR OPENING FORMED BY THE RISER. TREA &
CLOSED OFF. NO OPEN RISERS ALLOWED.
WITHOUT INTERRUPTION BY NEWEL POST OR OTHER
BOTTOM RAIL AT THE OPEN SIDE OF A STAIRWAY CAN BE OF
4. PROVIDE HANDRAILS EA. SIDE OF STAIRS. HANDRAILS TO BE
OBSTRUCTIONS.
A MAXIMUM SIZE SUCH THAT A SPHERE OF 6' IN DIA. CANNOT
1-Y2' GRASPABLE DIA. MIN. 34' -MAX. 38' ABOVE NOSE OF
3.
HANDRAILS SHALL RETURN TO A WALL. GUARD. OR
PASS THROUGH THE OPENING BETWEEN RISER. TREAD AND BTM.
TREAD/LANDING. MTD. 36' TYP. A.F.F. PROVIDE MIN. 1-1/2'
WALKING SURFACE OR SHALL BE CONTINUOUS TO THE
RAIL.
DISTANCE BETWEEN HANDRAIL AND WALL SURFACES.
HANDRAIL OF ADJACENT STAIR FLIGHT OR RAMP RUN.
4.
21' DIA. OPENING BETWEEN VERTICAL & HORIZONTAL MEMBERS
5. PROJECTIONS INTO CLEAR STAIRWAY WIDTHS SHALL NOT
WHERE HANDRAILS ARE NOT CONTINUOUS BETWEEN
IS ALLOWED IN INDUSTRIAL APPLICATIONS NOT ACCESSIBLE TO
EXCEED 4.5' AT OR BELOW THE HANDRAIL HEIGHT.
FLIGHTSTHE HANDRAIL SHALL EXTEND HORIZONTALLY AT
.
THE PUBLIC IN GROUP I-3. F. H. OR S OCCUPANCIES.
6. EXTERIOR TREADS/RISERS TO BE OPEN DIAMOND PLATE MESH
LEAST 12 INCHES BEYOND THE TOP RISER AND CONTINUE
5.
GUARDRAILS SHALL HAVE A HANDRAIL PER SECTION 1014 OF
TO ALLOW WATER/SNOW TO DRAIN.
TO SLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE
IBC
7. TREAD NOSING SHALL HAVE A CURVATURE OR BEVEL NOT LESS
4.
BOTTOM RISER.
HANDRAILS SHALL BE ON BOTH SIDES OF STAIRS.
THAN 1/16' BUT NOT MORE THAN 9/16'
5.
CLEAR SPACE BETWEEN HANDRAIL AND WALL SHALL BE
8. STAIR TREADS TO BE UNIFORM IN ANY FLIGHT OF STAIRS.
9. STAIR LANDINGS SHALL BE NOT LESS THAN THE WIDTH OF NOT LESS THAN 1.5.6. PROJECTION OF HANDRAIL FROM WALL SHALL NOT 1j DIA. STEEL POWDER COATED
STAIRWAY SERVED. LANDING DEPTH PERPENDICULAR TO STAIR EXCEED 4.5' HANDRAIL MTD. 36' A.F.F.
SHALL NOT BE LESS THAN STAIRWAY WIDTH. 7. CIRCULAR CROSS SECTION SHALL NOT BE LESS THAN TYP. EA. SIDE OF STAIR.
1.25' OR GREATER THAN 2'.
,,\,COMMON STAIR TOWER
9 RISERS 0 6.65'
10 TREADS 0 11'
,K 60' X 54' FRONT
APPROACH PULL
I SIDE CLEAR.
PLAN
413
2)
SCALE: 1/4'=1'-O'
RISERS 0 6.56'
RISERS 0 6.65'
10 TREADS 0 11'
V9
10 TREADS 0 11'
F9
5'-0'
T-4'
5'-0'
4'-10t
4'-10t
0
P
RAPET 42'-0' A.F.F.
10
EATHING 40'-7' A.F.F.
5'-0'
7'
4'
1
5,-0.
60' X 54' FRONT
0
o`F�
N. APPROACH PULL
SIDE CLEAR.
AL
9 RISERS 0 6.56'
10 TREADS 0 11'
PLAN
NDOW 1'-5' ABOVE 4TH F.F.
STAIR 313
20
H F.F. 31'-0-1/4' A.F.F.
SCALE: 1/4'=1'-O'
NDOW 8'-0' ABOVE 3RD F.F.
RISERS 0 6.56'
9 RISERS 0 6.56'
10 TREADS 0 11'
V9
10 TREADS 0 11'
5'-0.
T-4'
5'-0'
NDING 5'-0' ABOVE 3RD F.F.
4'-10t
4'-10f
mod- ."*
0 `F UP
NDOW 1'-5' ABOVE 3RD F.F.
F.F. 21'-2' A.F.F.
7' 4' 5'-0' 60' X 54' FRONT
NDOW 7'-11' ABOVE 2ND F.F. APPROACH PULL
0 `F DN. SIDE CLEAR.
NDING 4'-11' ABOVE 2ND F.F.
NDOW 0'-8' ABOVE 2ND F.F.
D F.F. 'IT-3-3/4' A.F.F.
NDOW 8'-8' A.F.F.
NDING 5'-8' A.F.F.
IISHED FLOOR 0'-0'
10 RISERS 0 6.78'
11 TREADS 0 11'
,,R �213
1-1/2' DIA. HANDRAIL 10 RISERS 0 6.78'
EA. SIDE MAX. 36' A.F.F. 11 TREADS 0 11'
EXTEND 12' TOP AND BTM.
L,,. 77�
OF STAIRS
5'-0' '-3
��% STAIR 106
SCALE: 1/4'•1'-0' `-
f
10 RISERS 0 6.78'
11 TREADS 0 11'
PLAN
SCALE: 1/4'=1'-O'
7
LINEN
CHUTE
PLAN
SCALE: 1/4'=1'-O'
C ARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
9 RISERS 0
6.65'
STANDPIPE COORD.
SUITE A
ROOF HATCH
V10 TREADS
0 11'
CLEARANCE REQ'S W/
FIRE MARSHALL
MOUNT VERNON, WA. 98273
ACCESS LADDER
5'-0.
T-4'
5'-0'
4'-10t
4'-10r
601 424-0394
Phone: R60
Fax: 424-5726
^3Nk
'ram
--'t
0 O
-6.
9
E STERED
HITECT
7PEERO
60' X 54' FRONT
APPROACH PULL
DN.
o p
TTTI
STATE WASHINGTON
SIDE CLEAR
1J DIA. STEEL POWDER COATED
HANDRAIL MTD. 36' A.F.F.
TYP. EA. SIDE OF STAIR.
STAI � 417
1
9 RISERS 0 6.65'-
10 TREADS 0 11'
4'-10r
UP.
60' X 54' FRONT
APPROACH PULL -
SIDE CLEAR
I� STAIR 318
5'-0'
4'-10t
60' X 54' FRONT
APPROACH PULL -
SIDE CLEAR.
UP
I R �219
\-9 RISERS 0 6.48'
10 TREADS 0 11' PLAN SALISH INN
907 30TH STREET
ANACORTES, WA 98221
SCALE: 1/4'=1'-0'
9 RISERS 0 6.56' STANDPIPE COORD.
10 TREADS 0 11' CLEARANCE REQ'S W/
FIRE MARSHALL
7'-4' 5'-0'
EK TERA ASARA, LLC
4'-10f 905 20TH STREET
9 RISERS 0 6.56'
10 TREADS 0 11'
9 RISERS 0 6.56'
10 TREADS 0 11'
7'-4'
ANACORTES, WA�98211
3 CONTACT: KULJIT SHOKER
-6 EMAIL: JAS.SH037@GMAILCOM
PHONE: 360J70-3701
MERtI
CONSTRUCTION
360.354.3500
PLAN
19-312
SCALE: 1/4'=1'-O'
STANDPIPE COORD. REVISIONS:
CLEARANCE REQ'S W/
5'-0' PI MARSHALL 6/14/19 PERMIT SUBMITTAL
4'-10t 8/27/19 PERMIT REVISIONS
3
� 0 0
2-HOUR RATED
STAIR
ENCLOSURE TYP.
0 0
FN
10 RISERS 0 6.78'
11 TREADS 0 11' PLAN SHEET TITLE:
1-1/2' DIA. HANDRAIL 20 RISERS 0 6.78'
EA. SIDE MAX. 36' A.F.F. 11 TREADS 0 11'
EXTEND 12' TOP AND BTMq
OF STAIRS
4'-1'
� � STAIR 111
STAIR TOWER
SCALE: 1/4'=1'-O'
STANDPIPE COORD.
CLEARANCE REQ'S W/
FIRE MARSHALL
''0 M 3
- 6.
;D
PJC
PROJECT ARCHITECT:
0
r0�
P J C
DRAWN BY:
jr PJC
CHECKED BY:
1-1/2' DIA. HANDRAIL
EA. SIDE MAX. 36' A.F.F. 02/08/19
EXTEND 12' TOP AND BTM.
OF STAIRS PLAN DATE
19-312.DWG
COMPUTER FILE NAME
SCALE: 1/4'=1'-0'
A-6.0
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
GRIND SMOOTH
ALL WELDS TYP.
POWDERCOATED
1 1/2' STEEL PIPE
W/ 3/4' STEEL PIPE
ATTACHMENT WELD
TO STEEL PLATE TYP.
(4) LAG BOLTS
INTO SOLID BLKG.
1L
>i
Q 0 0
4 X 4 STEEL PLATE
BRACKETS SPACED EQUALLY
(6 FT. O.C. MAX.) U.N.O.
0 WALL TYP.
POWDERCOATED
1 1/2' STEEL PIPE
W/ 3/4' STEEL PIPE
ATTACHMENT WELD
TO STEEL PLATE TYP.
BRACKETS SPACED EQUALLY
(6 FT. O.C. MAX.) U.N.O.
PROVIDE BLOCKING
IN WALL AS REQUIRED
TO ATTACH BRACKETS
WALL PER
WALL TYPES
LAG INTO WALL
SOLID BLOCKING
BLKG
SBER STAIR SKIRT
kRPET
BLKG
STRUCT.
R PER STRUC. BEYOND
8' GWB
SBER STAIR SKIRT
,RPET
! WD BLKG
RPET
B PLYWD
RINGER PER STRUC
YOND
Y GWB
�19 HANDRAIL � STAIR LANDING � STAIR TREAD
SCALE: 1 1/2'=1'-0'
17 SCALE: 3'=1'-0' 1 SCALE: 3'=1'-0'
NOTE: GWB OF 1-HOUR CLG TO RUN OVER
GWB/ HAT CHANNEL AND CAULKED/ SEALED
TO WALL TOP PLATE
Iu �
2X6 WD BLKG
RUBBER STAIR SKIRT
CARPET
CARPET
OSB PLYWD
BEAM
SEE STRUCT.
STRINGER PER STRUC
BEYOND
5/8' GWB
SEE WALL TYPES
RAMSET ANCHOR 0 24' O.C.
�OR A.B. PER STRUCT.
AT WOOD FRAMING
ATTACH PER STRUCTURAL
BASE & FINISH
PER SCHEDULE
PARTITION EASE
SECTION
SCALE: 3'=1'-O'
5/8' GYPSUM BOARD 0/
2X4 WD STUDS 6 16' O.C.
W/ 5/8' GYPSUM BOARD
f'0 COMMON
NALLS
FRAME TO B.O. OF
FLOOR/ CEILING
ASSEMBLY
1 X _ WD CAP
X 3 SKIRT
I8' GWB
X 4 WALL FRAMING
1 HOUR RATED CLG ASSEMBLY TYP.
rATTIC BATT INSULATION
I---PRE-FAB WD TRUSS
G TYPE 'X' GWe
'ER 1/2' HAT
IANNEL
TYP.
CLG GWB TO
I'E. CRITICAL
/ HAT CHANNEL
4LL WITH
' INSULATION
SIDES OF WALL
ARTITION HEAD TO CLG
LID
SCALE: 3'=1'-O'
RUBBER ST/
CARPET C
OSB PLYN
2X_WAL
PER PLAN
5/8' GWB
STRINGER
5/8' GWB
ENVELOPE REQUIREMENTS PER 2015 IECC, WSEC AMENDMENTS
REFERENCE CHAPTER 51-11C WAC FOR ENVELOPE REQUIREMENTS.
CONTRACTOR TO VERIFY ALL SUB TRADES RECOGNIZE ALL REQUIREMENTS TO
ACHIEVE ENVELOPE LEAKAGE MINIMUMS AS REGULATED BY STATE CODE.
CAULK ALL SILL PLATES ON INTERIOR AND EXTERIOR SIDE OF PLATES TO
ENSURE FULL BUILDING LEAKAGE SEAL. CAULK ALL WDO'S / PENETRATIONS
FOR AIR LEAKAGE SEAL.
INSTALL CLG GWB FIRST. CAULK SEAL GWB TO TOP PLATE OF ALL
PARTITION WALLS WITH FIRE RATED CAULK FOR 1-HOUR RATED CLG
ASSEMBLY AND AIR LEAKAGE SEAL PRIOR TO ANY WALL GWB INSTALLATION.
SEE SHEET A-0.1 FOR ADDITIONAL NOTES ON REQUIRED TESTING AND
CODE REFERENCES.
BUILDING OFFICIAL TO CHOOSE 12 UNITS AT RANDOM TO BLOWER DOOR
TEST.
NOTE CLG ASSEMBLY IS 1-HOUR RATED AND ALL PENETRATIONS MUST MEET
REQUIRED FIRE SAFETY RATING.
1-HOUR RATED WALL
5/8' GYPSUM BOARD 0/
1/2' HAT CHANNEL 0/
2X4 WD STUDS STAGGERED
16' O.C. 0/ 2X6 P.T. WD PLATE
W/ R-11 BATT INSULATION
W/ 1/2' RC CHANNEL
W/ 5/8' GWB
CAULK SEAL GWB
TO 1-HOUR RATED
CLG
2-HOUR RATED WALL
RUBBER STAIR SKIRT
STRINGER PER STRUC BEYOND
CARPET 0/
OSB PLYWD(TYP) <
1X2 WD BLKG
3/4' PLYWD(TYP)
PT 2X6 CONT. WD
w/NOTCH ®STRINGERS
/�DCCAI nl IIE BETWEEN GWB AT
;T TO LIVING UNITS
LAYERS 5/8'
TYPE (X)
rPSUM BOARD
0/
?' SHEATHING
PER STRUC.
;6 WD STUDS
0 16' O.C. W/
11 BATT INSULATION 0/
LAYERS 5/8'
TYPE (X)
rPSUM BOARD
0/
CAULK SEAL GWB
TO 1-HOUR RATED
CLG
FRAME TO B.O. OF
FLOOR SHEATHING
ABOVE
STAIR LANDING
F2-HOUR RATED WALL
T) 2X6 WD STUD WALL 2-HOUR- SHEAR scare s.r-o��
0
5/8' GYPSUM BOARD 0/
1/2' SHEATHING PER STRUC.
2X4 WD STUDS STAGGERED
16' O.C. 0/ 2X6 P.T. WD PLATE
W/ R-11 BATT INSULATION
1/2' HAT CHANNEL
W/ 5/8' GWB
CARPET 0/
OSB PLYWD(TYP)
CARPET 0/
OSB PLYWD(TYP)
C ARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: 4360� 424-0394
Fax: 360 424-5726
7AVSTERED
HITECT
r��
5-8-18
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
STRINGER PER STRUC EK TERA ASARA, LLC
BEYOND 905 20TH STREET
WD JOISTS ANACORTES, WA 98211
PER STRUCT. CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
5/8' GWB PHONE: 360-770-3701
r
[ARBE
CONSTRUCTION
360.354.3500
SCALE: 3'=1'-O'
19-312
/-IDCCAI "-I UE BETWEEN GWB AT
'XT TO LIVING UNITS
REVISIONS:
LAYERS 5/8' TYPE (X) 6/14/19 PERMIT SUBMITTAL
rPSUM BOARD 0/
r. 1/2' SHEATHING PER STRUC. 8/27/19 PERMIT REVISIONS
',6 WD STUDS 0 16' O.C. W/
11 BATT INSULATION 0/
LAYERS 5/8' TYPE (X)
fPSUM BOARD 0/
CAULK SEAL GWB
TO 1-HOUR RATED
CLG
FRAME TO B.O. OF
FLOOR SHEATHING
ABOVE
SHEET TITLE:
2 X 6 WD STUD WALL
WALL TYPES
2-HOUR- SHEAR
1-HOUR RATED WALL
SCALE: 3'=1'-0'
STAIR DETAILS
5/8' GYPSUM BOARD 0/
1/2' HAT CHANNEL 0/ 2X6
WD STUDS 0 16' O.C.
W/ R-11 BATT INSULATION
W/ 5/8' GYPSUM BOARD
PJC
PROJECT ARCHITECT:
PJC
CAULK SEAL GWB
DRAWN BY:
TO 1-HOUR RATED
CLG
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
2X4 WD STUD WALL- !„
NON BEARING
SCALE: 3'=1'-0'
�2X6 WD NON -BEARING �
SCALE: 3'-0' 3 SCALE: 3'=1'-0' 2
=1'
2X6 WD STUD WALL
SHEAR/ BEAR. scn�e 3.r-oC
2X6 WD STUD WALL
SCALE: 3'=1'-O'
A-6
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S
WINDOW PER SCHEDULE
FOR TYPE
AND SIZE TYPICAL
SHIM SPACE
B. ROD & SEALANT
MTL. 'L' FLASHING
'C' CLOSURE —
ADHERE TYVEK
STRAGHTFLASH TO
TYVEK FLEXWRAP AND
OVER BACK LEG OF
FLASHING PAN
WOOD JAMB/ HEAD —
AT ENTRY 100/
CONFERNECE 101 ONLY
WINDOW PER SCHEDULE
SET IN SHEET MTL. FLASH
PAN W/ END DAMS
SEALANT (TYP) SHIM SPACE
SEALANT (TYP)
5/4 WOOD B. ROD & SEALANT 1
5/4 WOOD
SILL W/ 1x3 APRON ROWLOCK SILL
SILL W/ 1x3 APRON
PRIME & PNT. TYPICAL
PRIME & PNT.
o PERM -A -BARRIER
o
FLASHING RUN
UP & OVER
WINDOW SILL 1
ADHERE TYVEK 1
—WD STUD WALL STRAGHTFLASH TO I
WD STUD WALL
PER WALL TYPES TYVEK FLEXWRAP AND I
PER WALL TYPES
OVER BACK LEG OF
FLASHING PAN
TYVEK COMMERCIAL I BATT TYVEK COMMERCIAL I BATT
WRAP I INSULATION WRAP I INSULATION
SHEATHING 1 5/8' TYPE 'X' GWBSHEATHING 1 5/8' TYPE 'X' GWB
MTL SIDING I BRICK VENEER
1' AIR SPACE
STOR��RONT SILL. MTL. STOR FRONT SILL. BRICK R <SHAPE
2 � SEE 1/A-6.2 SCALE: 3'=1'-0' � 9 SEE 1/A-6.2 SCALE: 3'=1'-0'
SEALANT TYP.
STOREFRONT WINDOW PER
PLAN ATTACH FRAME MIN. 1/2'
OVER EDGE OF FOUNDATION
PER MANUFACTURER'S SPEC'S
SHIM SPACE
SEALANT AND BACKER —
ROD BOTH SIDES TYP
CONC FOUNDATION WALL
W/ REINFORCING PER STRUCT
(FLOORING PER SCHEDULE)
RIGID SLAB EDGE
INSULATION PER TY�
WALL SECTIONS
ELASTOMERIC SEALANT
W/ ASPHALT EXPANSION
JOINT
3/_4'
SLOPE 1/8'
PER FOOT
W/ AIR GAP
SECTION
STOR. WDO SILL @ CONC. STOREFRONT @ CMU
SSCALE: 310
EE 1/A-6.2 SCALE: 3'=1'-0' � 4 SEE 1/A-6.2 SCALE: 3'--1'-0' 1 3 SEE 1/A-6.2 12 SEE 1/A-6.2 SCALE: 3'=1'-0'
-21 BATT BATT INSULATION-
gSULATION W/ MIL VAPOR
BARRIER
iEALANT (TYP) 5/8' GWB
HIM AS REQ'D (TYP)
2X6 FRAMING W/ -
f2' SHEATHING BATT INSUL.
FILL BACK OF
5/8' GWB .
5/8' G)
R-21 BATT
TAPE- MUD
LUIM. STOREFRONT
INSULATION
PREP FOR
DO
PNT.
R-21 B�
SEALANT (TYP)
ETURN CORNERS
2 X 6
IN. 2'
SHIM AS REQ'D (TYP)
HEADS
1/2' SHEATHING
STRUC
TL POST PER STRUC.
WINDOW PER
SCHEDULE
I
�
I
SEAL V
------- ---
TAPE
METAL WALL PANELS
PER ELEVATIONS
1/2' SHEATHING W/
TYVEK COMMERCIAL
WRAP RUN OVER TOP
OF ALL FLASHING
TYVEK FLEXWRAP
• \ I MTL 'L' FLASHING
SHIM AS REQ'D I ATTACH W/ MECH
BACKER ROD & FASTNER
SEALANT (TYP) MTL FLASHING
MTL TRIM FLASHING TYVEK WRAP I SET INDRIP EDGE BED
TL. BREAK FLASHING
TO MATCH EXIS
TIN
G CORNER BEAD SEALANT/ BACKEROD
MTL (TYP.)
NEOPRENE CLOSURE PANELS LL J RUNNER (TYP) PER LSCHIED�LE
SET IN SEALANT
GAS2. wew� �.���
STOREFRONT JAMB @ MTL./WINDOW HEAD � MTL.
(::
SCALE: 3'=1'-0' SEE 1/A-6.2 SCALE: 3'=1'-O' SEE 1/A-6.2 SCALE: 3'=1'-0'
TURN UP TYVEK FLEXWRAP
-MTL WALL PANELS AND ADHERE TO BLOCKING
WINDOW SET IN SHEET
1/2' SHEATHING MTL. FLASHING PAN 5/8' GWB V.B. PNT.
W/ END DAMS CONT. MIL VAPOR
SEAL TYVEK FLEXWRAP BARRIER
TYVEK COMMERCIAL GWB SILL TO TYVEK
CAULK
Ll BACKER ROD
AND SEALANT
MTL. 'L' FLASHING ALUM. NAIL
2 X 6 FRAMING FLANGE
)QC —\/ \/ J WINDOW
1�i'1►�J
IINDOW PER
CHEDULE
HEADER W/ R-10
INSUL. PER CODE
LL
L L_As
I
TYVEK STRAIGHTFLASH
LLI
VF
TEMPORARY 3/4'
5/8' GWB HEAD &
LLL
SEAL BOTTOM USING
MARINE GRADE PLY
JAMB W/ J TRACK.
LLLI
3' TYVEK TAPE
STORE SITE
CORNER BEAD &
LL
CAULK
SEALANT, TYP.
i
MTL L TRIM ATTACHED
LLL_
W/ GASKETED SCREWS
�ACKER ROD &
I
0 48' O.C.
EALANT (TYP)
YVEK COMMERCIAL
WRAP
GWB W/ PN
'LOSURE BATT INSUL.
PRENE CLOSURES
1/2' SHEATHIN
SHEATHING W/ W/ TYVEK
EK COMMERCIAL COMMERCIAL '
P
DOOR PER SCHEDULE
FFSET SADDLE
HRESHOLD
IAX. 1/2' THRESHOLD
ET INTO SEALANT
ONC FOUNDATION
1/2' COMPRESSIBLE
Q JOINT FILLER W/
ELASTOMERIC SEALANT
CONC SLAB
SLOPE 01/8'/FT,
STOREFRONT DOOR
PER DOOR SCHEDULE
CONCEALED BOTTOM RAIL
WEATHERSTRIP
ALUMINUM DOOR THRESHOLD
MAX. 1/2' ABOVE FLOOR
CONC SLAB
� EXT. H.M.D. THRESHOLD �)STOREFRONT SILL
10 SEE 1/A-6.2 SCALE: 3'=1'-0' g SEE 1/A-6.2
\,INT HMD HEAD
R-11 SOUND BATTS
WD STUD WALL PER
WALL TYPES
HEADER PER STRUCTURE
5/8' TYPE 'X' GWB. PNT.
EA SIDE
HOLLOW METAL
DOOR FRAME
DOOR PER
DOOR SCHEDULE
SECTION
SCALE: s•=r-o• 4�� N T. H M D JAM B
SCALE: 3'=1'-O'
WD STUD WALL PER
WALL TYPES
R-11 SOUND BATTS
HOLLOW METAL
DOOR FRAME
DOOR PER
DOOR SCHEDULE
5/8' TYPE 'X' GWB. PNT.
EA SIDE
PLAN
I
SCALE: 3'=1'-0'�
2'x4-1/2' 6
STOREFRC
WINDOW
ALUMINUM
STOREFRC
DOOR
TEMPERED
SHIM SPAT
1X3WD
SEAL RUN
PRIME & f
5/8' GWB
BOTH SIDI
SECTION
D
STnRwDO sri i i SrnRnRcTnppFn r�� �n�n c,� L
SEE 1/A-6.2 SCALE: 3'=1'-0' 7 SCALE: 3'=1'-0'
5/8' GWB BOTH SIDES
WALL FRAMING PER WALL
TYPES TYP.
CAULK
FLASH COVE CAP
STRIP v
SHEET VINYL
W/ 6' COVED ZO
SHEET VINYL
BASE
MTL L FLASHING
GWB BATT INSULATION
BEYOND _� TOREFRONT WINDOW W1 MIL VAPOR
1' BARRIER L r
TOREFRONT FLANGE HEAD WINDOW SILL @ MTL
MTL SIDI
SET IN SEALANT
WI NSOW JAM B@ MTL
R,
WD S"
WALL
5/8' GWB
BOTH SIDI
TEMPERED
SHIM SPAI
GENERAL NOTES:
1. SEAL ALL TYVEK JOINTS AND PENETRATIONS WITH APPROVED TAPE.
(ex. DUPONT CONTRACTOR TAPE).
2. FASTEN TYVEK F TO SHEATHING WITH LARGE HEAD NAILS
OR USE NAILS WITH LARGE PLASTIC WASHER HEADS.(ex. DUPONT WRAPCAPS)
3. ALL SIDES WINDOWS JAMBS SILLS AND HEADS TO RECEIVE FLEXWRAP
INSTALLED PER MANUFACTURERS INSTRUCTION.
4. CAULK SEAL WDO TO FRAMING ON ALL SIDES OF WDO IN ORDER TO PASS
THE AIR BUILDING LEAKAGE TESTING AS MANDATED BY ENVELOPE REQ'S PER
2015 IF -CC AND WSEC AMENDMENTS.
5. CAULK SEAL EXTERIOR WALL PLATE TO SLAB ON INSIDE. CAULK SEAL TYVEK
WRAP TO PLATE ON OUTSIDE IN ORDER TO PASS THE AIR BUILDING LEAKAGE
TESTING AS MANDATED BY ENVELOPE REQ'S PER 2015 IECC AND WSEC AMENDMENTS.
6. ENSURE REQ'D ON SITE MEETING WITH TYVEK REP IN ORDER TO OBTAIN
MANUFACTURES. WARRANTY
CARLETTI ARCHITECTS Po
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: 4360� 424-0394
Fax: 360 424-5726
s42s
E STERED
STATE 0 WASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
'RAIGHTFLASH 905 20TH STREET
TO SEAL TO
VEKAND ANACORTES, WA 98211
NDOW FRAMECONTACT: KULJIT SHOKER
�CKER RODEMAIL: JAS.SHO37@GMAIL.CO�
JD SEALANT PHONE: 360-770-3701
TL TRIM
_ASHING
MATCH ���(ISTING
ix
mmm
CONSTRUCTION
360.354.3500
SEE 1/A-6.2 SCALE: 3 =1-0
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
8/27/19 PERMIT REVISIONS
SECTION SHEET TITLE:
STOPPED IN WD HEAD N1D0 DETAILS
SCALE: 3'=1'-0'
NOTE: GWB
OF 1-HOUR CLG TO
RUN OVER
GWB/ HAT
CHANNEL AND CAULKED/
SEALED
TO WALL TOP PLATE
TYPICAL WALL
SIDING PER PLAN
TYVEK COMMERCIAL WRAP
SHEATHING (PER STRUCT)
WOOD STUDS
BATT INSULATION
VAPOR RETARDER
GYPSUM BOARD
0
LAP AND TAPE TYVEK
i%
®
AT JOINTS
Pic
PROJECT ARCHITECT:
0
Pic
°
BUTTON CAP STAPLE
DRAWN BY:
FASTENERS TYPICAL
FASTEN SING �<'FLEXW MECHANICAL
° � Pic
CORNER USING MECHANICAL � o � PER MANUFACTURERS
FASTENER DIRECTION CHECKED BY:
CONCRETE SLAB J INSTALL TYVEK kFLEXWRAPi11
ON GRADE OR AROUND PERIMETER OF OPENING
GYP CRETE WHERE
OCCURS CAULK/SEAL ° IC
AROUND PERIMETER OF OPENING o CAULK/SEAL
WALL BASE PLATE
OVED BASE DETAIL WINDOW DOOR WALL WRAP DETAIL
SCALE: 3'=1'-0'
FLASH COVE STICK
SCALE: N.T.S
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
-6.
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S
5/8' GWB
BATT INSUL.
2x6 FRAMING
15
—TYVEK COMMERCIAL
WRAP
TYVEK STRAIGHTFLASH
VP
SEAL BOTTOM USING
3' TYVEK TAPE
MTL L TRIM ATTACHED
W/ GASKETED SCREWS
0 48' O.C.
,-LAG ATTACHMENT
1/2' SHEATHING
TERMINATION
BAR
TPO ROOFING RUN UNDER
TERMINATION BAR. BAR SHOULD
MAINTAIN 18' ABOVE ROOF
1' AIR SECTION
L
SPACE 1/2' SHEATHING
TERMINATION BAR
w
z
3
SCALE: N.T.S. 14
1HEAD @ SLIDER
I V � SEE
14/A-6.2
HORIZONTAL MTL
NEOPRENE CLOSURE SET
SIDING
IN SEALANT TOP
AND BOTTOM
MTL FLASHING
STOREFRONT
TYVEK
BACKER ROD/
TRANSOM
COMMERCIAL
SEALANT
WINDOW ABOVE
WRAP
COORDINATE
1/2' PLYWOOD
WITH WINDOW
MANUF.
MOTOR PER
MANUFACTURER
MOTION PRESENCE SENSOR
ALUMINUM SLIDING
DOORS PER DOOR
SCHEDULE. PER
MANUFACTURER
2x6 FRAMING
SECTION 5/8' GWB V.B. PNT.
BATT INSUL.
TANLEY @ HEAD @ EXT. TL TO MTL TRANS.
SHEATHING
GWB
`.K COMMERCIAL WRAP
SIDING
>ER PER STRUCTURAL
K STRAIGHTFLASH VP
BOTTOM USING
'VEK TAPE
L TRIM ATTACHED
GASKETED SCREWS
.8, O.C.
FLASHING
2'x2' GUARD RAIL 42' ABOVE
DECK
OPERABLE PANEL IS II III FIXED PANEL
INTERMEDIATE RAILINGS
CONTRACTOR BIDDER DESIGN
FLOORING SEALANT SEE GUARD RAIL NOTES ON
SHEET A-6.0
EXTERIOR FLOORING DECK TOP COATING
ti
OVER SHEATHING LOWER RAIL SUPPORT
RECESS
,ANT
SEAL ALL SCREW---/
HEADS AT SILL
1/4' DIA. FLAT HEAD
CONC. ANCHORS
SILL @ SLIDER
SCALE: 3'=1'-0' 17 SEE 14/A-6.2
VERTICAL MTL SIDING
MTL. FLASHING
CONT. BED OF - - LAG INTO BLOCKING TYP.
NON -SHRINK _� _ DECK FRAMING PER
HYDRAULIC GROUT STRUC. PNT.
BEAM PER STRUC. PNT.
GUARDRAIL
16
SCALE: 3'21'-0' SCALE: 1'=1'-0'
RIGID INSULATION
TYVEK TPO ROOFING TURN
COMMERCIAL WRAP 7 DOWN GUTTER
WOOD SILL/ APRON PER —
MATERIAL SCHEDULE
TYPICAL WALL CONSTRUCTION
2 X 6 FRAMING PER STRUCT
WALL TIES I
4' CMU VENEER
® 16' O.C.
0/ 1' AIR SPACE
VERTICAL TYP. I
0/ TYVEK COMMERCIAL WRAP 0/
R-21 BATT INSULATION
1/2' SHEATHING 0/
5/8' GWB. PNT.
2X6 WOOD STUDS 0
16' O.C. W/ R-21 BATT
> I
INSULATION W/
VAPOR BARRIER W/
5/8' TYPE 'X' GWB.
P-TAC UNIT PER MECH.
_______ _
6 J
PAINT
SET P-TAC FLUSH WITH WALL
MIN. INTRUSION INTO INTERIOR
TYVEK COMMERCIAL WRAP
SPACE
'
— LAP 6' OVER FLASHING
�i
NERVESTRAL
CONCRETE SLAB/
— a
FLASHING
FOOTING/ STEM
o 0
—_ WEEPS 0 32' O.C.. MAX
WALL PER STRUCTURAL
_ 1 i _
FILL AIR SPACE
— W/ PEA GRAVEL
i
BELOW SLAB
FOOTING/ STEMWALL/
Ed
REBAR/ ANCHOR BOLT
_
11 PER STRUCTURAL
11 El I E111-111-115:
��TYPICAL PRICK VENEER �)-SEE
P-TAC
SCALE: 1'=1'-0' 9 1/A-6.2
SIDING
tENE CLOSURE
TRIM
`K COMMERCIAL
°ATHING
FRAMING
T INSUL.
GWB
PLAN
SCALE: 3'=1'-0' 13 SCALE: 3'=1'-0'
4'
o 1/2' SHEATHING W/
TYVEK WRAP
MTL SIDING
N
MTL 'L' TRIMS W/ TEK
SCREWS
MTL DRIP EDGE
FLASHING W/ BACKER
ROD/ SEALANT
SECTION
CONDENSATE
DRAIN
MTL DRIP EDGE
FLASHING W/ BACKER
ROD/ SEALANT
MTL SIDING
I- L f-\ IN
ETAL TRIM
:H. FASTNER
iT.
PLYWOOD
COMMERCIAL
NG
ROOF SLOPE
1/4':1'-0' GASKETED TEK SCREW
METAL DRIP EDGE
/7
12
2 X 4 P.T. NAILER
6' MTL. BOX
GUTTER
MTL TRIM
NEOPRENE CLOSER STRIP
MTL SIDING
6' MTL. BOX
GUTTER
UTTER @ ROOF
METAL SIDING
1/2' PLYWOOD W/
TYVEK COMMERCIAL WRAP
2 X 6
FRAMING
SCALE: 3'=1'-0'
EOPRENE CLOSURE BACKER
SET IN SEALANT ROD/
SEALANT
STRAIGHTFLASH VP
TO SEAL TO TYVEK
HM DOOR AND FRAME
SOLID IGROUT SCHEDULE
BATT INSUL.
5/8' GWB
NEXT. H M F JAMB
SCALE: 1'=1'-0' MTL SIDING
SCALE: 3'21'-0'
SEE 14/A-6.2
MTL CORNER BEAD
MTL SIDING
�
2x6 FRAMING
TYVEK COMMERCIAL
BRICK VENEER
WRAP
I
TYVEK COMMERCIAL
5/8' GWB
WRAP
TYVEK STRAIGHTFLASH
VP
2x6 FRAMING
BRICK VENEER
SEAL BOTTOM USING
1
1' AIR SPACE
I
3' TYVEK TAPE[.
MTL L TRIM ATTACHED
-
BATT INSUL.
W/ GASKETED SCREWS
3
® 48' O.C.
1
z
2' PLYWOOD
I
CEDAR SHIM FOR SLOPE
3
BACKER ROD —
1/2' PLYWOOD
& SEALANT 1
TYVEK COMMERCIAL
24 GA. MTL.
WRAP
FLASHING TUCK
UNDER MTL SIDING
18' GWB
ATT INSUL.
BRICK VENEER
1
1' AIR SPACE
PLAN
PLAN
SECTION
1/2' SHEATHING
1' AIR
SPACE
SCALE: 3'=1'-0'
5/8' GWB
BATT INSUL.
2x6 FRAMING
2'-0'
6X6HSS
COLUMN PER
STRUCTURAL.
0
N
8' SOLID GRO
GROUND FACE
TYP.
PROVIDE CMU CAP
3/4' DIA. X 2-1/2' THREADED RODS WELDED TO T.S.
COLUMN PER STRUCTURAL 0 24' O.C. CONNECT INTO
CMU COLUMNS PLAN
" * " ,� CM�UCOLUMN
SCALE: 1 1/2'=1'-O'
1TT INSUL.
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: 4360� 424-0394
Fax: (360 424-5726
6429
RE STERED
H ITECT
STATE 0 WASHINGTON
5-8-19
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAILCOM
PHONE: 360-770-3701
c DER
CONSTRUCTION
360.354.3500
19-312
SHEATHING
s• GWB REVISIONS:
'VEK COMMERCIAL WRAP
L SIDING 6/14/19 PERMIT SUBMITTAL
ADER PER STRUCTURAL 8/27/19 PERMIT REVISIONS
VEK STRAIGHTFLASH VP
AL BOTTOM USING
TYVEK TAPE
ITL L TRIM ATTACHED
I/ GASKETED SCREWS
48' O.C.
ITL L FLASHING
ALANT
HM DOOR AND FRAME
PER FIN. SCHEDULE SHEET TITLE:
SOLID GROUT
6)EXT. H M H �EA11 DOOR DETAILS
_ SEE 14/A-6.2 SCALE: 3'=1'-0'
5/8' TYPE X
GWB
BATT INSULATION
2X6 WD STUD WALL
00 PER WALL TYPES
HOLLOW MTL. FRAME
GROUT SOLID PAINT
SHIM
TYVEK Pic
COMMERCIAL WRAP PROJECT ARCHITECT:
SHEATHING
STRAIGHTFLASH VP TO PJC
SEAL TO TYVEK AND DRAWN BY:
WINDOW FRAME PJC
' I DOOR AND FRAME CHECKED BY:
PER DOOR SCHEDULE
SEALANT AND 02/08/19
BACKER ROD DATE
1' AIR
SPACE 19-312.DWG
BRICK COMPUTER FILE NAME
VENEER
EXT. H.M.D. JAMB @ BRICK A- 6
SEE 14/A-6.2 SCALE: 3'=1'-0' °
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.
1/2" M
(3 mn
HOT PIPE EXIST.
- SEALA RAIN HOOD
WATER CUT-OFF MASTIC
STAINLESS STEEL CLAMPING RING
METAL COLLAR
(SEE NOTE 3)
FLASHING MEMBRANE
HOT AIR WELD
ROOFING
MEMBRANE
INSULATION
APPLY HEAT TO FLASHING
AND FORM BY HAND PRIOR
\ TO HOT AIR WELDING
/ STRUCTURE
1"MIN. Ij
2.5 cm 1. -
APPRO .) M
NOTES:
1. FIELD FABRICATED PIPE FLASHING
FOR USE WITH HOT PIPE. 12V F
(49' C) OR HOTTER.
2. FLASHING
MEMBRANE WRAPPED AROUND
PIPE SHALL HAVE MIN. 1-1/2-
(4 cm) VERTICAL HOT AIR WELD.
3. TEMPERATURE OF METAL
COLLAR MUST NOT EXCEED
120' F (49' C).
ROOF PENETR
MTL FLASHING UP PARAPET--,,
EXTEND SADDLE DOWN -
BACK SIDE OF PARAPET
OVER TPO ROOFING
LOWER PARAPET
FRAMING. SADDLE
FLASH OVER
BUILDING WRAP/
TPO. CAP FLASH
AND SIDING OVER
TOP
031
1-HOUR RATED CLG I
ASSEMBLY o
0
SOFFIT FRAMING
BELOW CLG GWB.
HOLD DIMENSION
TIGHT TO DUCTING
WD SOFFIT FRAMING
0'-10'
ATIO
NOTE 1
WATER CUT—OFF MASTIC
STAINLESS STEEL til
CLAMPING RING
I
PIPE SEAL
ATION
44 m1/2"
c)
HOT AIR WELD
(NOTE 3)
MEMBRANE
ROOF
STRUCTURE
NOTES:
HN AN
1. TEMPERATURE OF PIPE MUST NOT EXCEED am
120' F (49' C).
2. PIPE SEAL MUST HAVE INTACT RIB AT TOP
EDGE, REGARDLESS OF PIPE DIAMETER.
3. PIPE SEAL DECK FLANGE MUST BE HOT
AIR WELD A MINIMUM OF 1 1/2" (4 cm).
4. INSTALL A SECTION OF TPO WE
MEMBRANE OVER SEAM INTERSECTIONS
PRIOR TO INSTALLING PRE —MOLDED PIPE SEAL
N ROOF PENETR
SCALE: N.T.S.' 17
—VAKAVr- I I-•KAM1NU
AND BUILDING
WRAP/ TPO
HARDIE SIDING
COVER TOP OF MTL FLASHING
SADDLE FLASH W/ HOLES DRILLED
0 24' O.C. MITRE
ALL CORNERS
MTL FLASHING
BLOCKING
T.O. LOWER LIGHT FIXTURE
PARAPET WALL
11' X 18' STEEL PLATE
24 GA. GALVANIZED
SADDLE FLASHING W/ MTL TRIM
SOLDERED JOINTS EXTEND
OVER ALL FACES OF MTL. PANELS 0/
FRAMING TYVEK COMMERCIAL WRAP 0/
1/2' SHEATHING 0/
2X6 FRAMING W/ R-21 INSULATION 0/
5/4' GWB
R.R. EXHAUST
VAN DUCTING
1�1.M1E
MK 1-1/r Hm M Ma
ATION
N.T.S.
NOTE SIM CONDITION:
P.T. BLOCKING AT EXISTING
CMU WALL. SIDING &
FLASHING REMAINS SAME
T�
T.O. CEILING
EXTEND LADDER TO TOP
OF ROOF HATCH
WELDED GALV. STEEL LADDER
W/ 2-1/2'x 3/8' BAR STRINGERS
& 3/4' 0 RUNGS 0 1'-0' O.0
W/ 3'x8'x1/4'
ANGLES WELDED TO STRINGERS
ON LADDER AND 0 WALL ATTACHE
W/ 1/2'x4' LAG BOLTS /
2-EA ANGLE
4 X 6 SOLID "
BLOCKING IN WALL
FRAMING 0 WALL ATTACHMENT
TYP.
T.O. SLAB
ACCESS LADDER
DOWNSPOUT STRAP —
FASTEN TO WALL
PANEL W/ WALL
STITCH FASTENER
BEND TAB TO
SECURE BOTH
HALVES OF STRAP
TOGETHER. 2 STRAPS
PER 10' SECTION OF
DS
DS BOOT CONNECT
TO APPROVED
OUTFLOW
6' PVC, PNT.
CONNECT TC
TIGHT -LINE
22 X 36 (1) HOUR SMOKE RATED ACCESS HATCH AT
(5) LOCATIONS TO ACCESS ATTIC TYPICAL 1/8' JOINT 0 BREAK
METAL SECTIONS FOR
EXP./ CONTRACTION
24 GA. GALV. JOINT
BLOCKING
COVER 0 BREAK MTL.
BETWEEN
SECTIONS. SET IN BED
TRUSSES TYP.
OF SILICONE SEALANT
SLOPE TO
T.O. TRUSS
INSIDE
13'-0' AFF
PARAPET
5/8' GWB 0/ 1/2'
RC CHANNEL
PNT. TYP. (1 HOUR)
T.O. CEILING
9'-0' AFF
ACP CEILING v I IIIII
FRAME FINN WALLS
DOWN W/ GWB (4)
SIDES TO FORM
SHAFT
z
:2 SEALANT
TJI JOISTS �' I
PER STRUCT
DOUBLE —
LSL BLOCKING
PER STURCTURAL
HANGER
N
SCALE: GOOF HATCH
NOTE: SEE ROOF PLAN
FOR QUANTITY OF DS
CONNECT TO GUTTER AS
REQ'D PER MANUFACTURER
-10
R.R. VENT SOFFIT 1 HOUR CEILING ACCESS PARAPET COPING
g SCALE: 1 1/2'=1'-0' 8 Do(
DOOR
�8�
L O C SCALE: 1 1/2'=1'-0' 7
3X4 ALUMINUM SMOOTH
FACE DS FASTEN TO DS
NIPPLE W/ 3 POP RIVETS
5
PARTITION WALL —
ALL WIRE TIES ARE TO BE (3)
TIGHT TURNS AROUND ITSELF
1ITTI IT\1 2
WIRE TIES
j WALL
8' MAX.
'MIN.
O O � M O
0 0 0 0 0 0 0 0 0 0 0 0
WALL MOLDING
' MIN.
NOTE: (1) END OF CEILING GRID SHALL BE ATTACHED TO WALL
MOLDING, THE OTHER END SHALL HAVE A 3/4' CLEARANCE FROM
WALL & FREE TO SLIDE. GRID SHALL BE ATTACHED AT (2)
ADJACENT WALLS (POP RIVETS OR APPROVED METHOD)
GRID AT WALE
SCALE: N.T.S. SCALE: N.T.S. 3
-PREMANUF. ROOF
HATCH W/SELF-
FLASHING CURB
1' RIGID INSULATION
-STEEL ANGLE. NOTCH
AND BEAR ON JOISTS
TYP. ALL 4 SIDES
-SUPPORTS 0
4'-0' O.C.. MAX
SEE DETAIL
13/A-6.4
1/2' SHEATHING
0 LADDER ONLY
1/4' TH. STL. WELDED TO STL.
SEALANT
—CANT. RUN ROOFING
UP CURB
TJI JOISTS
PER STRUCT
HANGER
DOUBLE LSL BLOCKING
PER STRUCTURAL
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: E360� 424-0394
Fax: 360 424-5726
6429
E STERED
HITECT
PETER TTI
STATE 0 WASHINGTON
SCALE: N.T.S. 5-8-19
ANGLE & BOLTED TO DBL WD STUD 24 GA. SHEET MTL
ALL WOOD TO BE FIRE TREATED PARAPET CAP
MIRROR KYNAR 500 FINISH SALISH INN
4" SOLID SURFACE 2X2 CONTINOUS BEVELED SIDING 907 30TH STREET
BACKSPLASH P.T. BLOCKING SHIM TO SLOPE
ANACORTES, WA 98221
SOLID SURFACE COUNTER
NEOPRENE
2x CONT. CLOSURE
IL CONT. MTL TECH SC EW
`t w CLEAT 0 24' O.C.
>
FASTEN
I
EK TERA ASARA, LLC
0 24' O.C.
1x4 BLOCKING AT BRACE
905 20TH STREET
2 X 6 FRAMING
I
I
ANACORTES, WA 98211
2"x2"x24" LG. STL. ANGLE BRACE
I
CONTACT: KULJIT SHOKER
THRU BOTT. 0 STUD WITH (4)
I
EMAIL: JAS.SH037@GMAIL.COM
1/2' DIA. M.B.. COORD. w/
MTL SIDING
PLUMB'G NOT TO EXCEED
PANELS
T.P.O. SINGLE PLY
PHONE: 360-770-3701
48' O.C.
MEMBRANE
INSULATION WRAP
1/2' SHEATHING
I
WRAP UP &OVER
BOTH SIDES
I
PAPAPET WALL &
r
KNEE BRACE AS REQUIRED
DOWN FACE MIN. 2'
TYVEK COMMERCAIL
— FRP OR P-LAM WAINSCOT
WRAP
CONSTRUCTION
PER FINISH SCHEDULE
360.354.3500
DETAIL , NHKANt I (;AN @ NEW.
C, A _ , , „ SCALE: 3., o
VERTICAL 9 GA HANGER SPACED
4'-0' O.C. ALONG MAIN RUNNER TO
STRUCTURE ABOVE.
COMPRESSION STRUT 0 12'-0' O.C.
(4) 12 GA WIRES SECURED TO MAIN
RUNNER.
SPLAY 90D FROM EA OTHER, N.T.E.
45 FROM CLG PLANE. HORIZONTAL
RESTRAINT POINTS SHALL BE PLACED
12'-0' O.C. IN BOTH DIRECTIONS, W/
THE FIRST POINT WITHIN 4'-0' FROM
EA WALL. SECURE TO STRUCTURE
ABOVE.
1 1/2' COLD ROLLED CHANNEL
0 4'-0' O.C.
7/8' HAT CHANNEL
0 2'-0' O.C.
I6\SUSPENDED GWB
SCALE- N.T.S. \
SUPPORT WIRES
SEE A.C.T. SWAY
BRACE DETAIL
VERTICAL STRUT
CAPABLE OF RESISTING
VERTICAL LOADS
CEILING BRACE
VERTICAL 12 GA HANGER SPACED
4'-0' O.C. ALONG MAIN RUNNER TO
STRUCTURE ABOVE.
(4) 12 GA WIRES SECURED TO MAIN
RUNNER WITHIN 2' OF CROSS RUNNER
SPLAYED 90 FROM EA OTHER. N.T.E.
45 FROM CLG PLANE. HORIZONTAL
RESTRAINT POINTS SHALL BE PLACED
12'-0' O.C. IN BOTH DIRECTIONS. W/
THE FIRST POINT WITHIN 4'-0' FROM
EA WALL. SECURE TO STRUCTURE
ABOVE.
MAIN RUNNER
A.C.T.
\ CROSS RUNNER
NOTE: SUSPENDED CLG SHALL BE INSTALLED PER 2003 IBC AND
ASTM C 635 and ASTM C 636.
2 A.C.T. SWAY BRACE
SCALE: N.T.S.
SCALE: N.T.S.
NOTE: GWB OF 1-HOUR CLG TO RUN OVER
GWB/ HAT CHANNEL AND CAULKED/ SEALED
TO WALL TOP PLATE
MAX. TYP.
19-312
VERTICAL STRUT
0 12'-0' O.C.
REVISIONS:
6/14/19 PERMIT SUBMITTAL
12 GA. SWAY SUPPORT
8/27/19 PERMIT REVISIONS
WIRES 0 12'-0' O.C.
9 GA. SUSPENSION WIRE
0 4-0' O.C.
COLD ROLLED CHANNEL
0 4-0' O.C.
16 GA. TIE WIRE
5/8' GWB
HAT CHANNEL
0 2-0' O.C.
SHEET TITLE:
WALL TYPES
N.T.S
STAIR DETAILS
#12 GA. WIRE HANGER TO
STRUCTURE AT EACH
CORNER OF FIXTURE
ATTACH SLACK WIRES
DIRECTLY TO FIXTURE
AT DIAGONAL CORNERS
PJC
PROJECT ARCHITECT:
PJC
ATTACH FIXTURE TO DRAWN BY:
CEILING SUSPENSION
SYSTEM WITH POSITIVE PJC
CLAMP DEVICES HAVING CHECKED BY:
CAPACITY OF 100% OF
LIGHTING FIXTURE WEIGHT
IN ANY DIRECTION 02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
SIGHT FIX. SUPPORT A - 1 0
SCALE: N.T.S.
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.