Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0021 5203 Doon Way (4)u HIMIZU= MITH REMODEL 5203 DOON WAY ANACORTES, WASHINGTON PARCEL I D# P60031 SKYLINE NO 11 LOT 18 PROJECT DESCRIPTION: INTERIOR REMODEL OF 1-1/2 STORY SINGLE FAMILY RESIDENCE. NOTE: NO CHANGES WILL BE MADE OUTSIDE OF EXISTING FOOTPRINT. NOTE: IN THE SECTION OF THE HOUSE WHERE WALL CHANGES ARE TO BE MADE (IE: KITCHEN/GREAT ROOM AREA) THE ROOF STRUCTURE IS PRE -MANUFACTURED ROOF TRUSSES. IT IS PRESUMED THERE ARE NO INTERIOR BEARING WALLS AT THIS SECTION. BUILDING CODES CONSTRUCTION WILL COMPLY WITH: 5UILDING ;STRUCTURAL 2015 IRC MECHANICAL 2015 IRC PLUM5ING 2015 UPC ENERGY ; VENTILATION 2015 WSEG FLOOR PLAN NOTES • THE FOLLOWING NOTES REFER TO ANY NEW FLOOR PLAN ELEMENTS. • WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. • CONFIRM ALL DOOR, WINDOW, CLOSET, AND ANY OTHER ROUGH OPENING SIZES WITH OWNER/ CONTRACTOR PRIOR TO WALL CONSTRUCTION. • ALL WOOD IN CONTACT WITH CONCRETE MUST 5E PRESSURE TREATED MATERIAL. USE CORROSION RESISTANT FASTENERS WHEN IN CONTACT WITH PRESSURE TREATED LUMBER. • ALL INTERIOR WALLS TO 5E FRAMED WITH 2 X 4 STUDS AT Ifo° O.G. AND SHEATHED WITH 1/2' GYPSUM WALL50ARD UNLESS NOTED OTHERWISE. • ALL GLASS TO HAVE LOW E (0.40) GLAZING. GLAZING IN HAZARDOUS LOCATIONS TO 5E TEMPERED PER IRC SECTION R305. SEE R305.4 FOR DEFINITION OF HAZARDOUS AREAS. • ALL SHOWER AREAS TO 5E FINISHED WITH A SMOOTH, HARD I NON -ABSORBENT MATERIAL TO MIN. 12` A50VE DRAIN INLET. THIS MATERIAL TO 5E INSTALLED OVER WATER RESISTANT PLASTER BOARD. • TOILETS TO 5E LOCATED IN AREA WITH MIN. 3e` WIDTH OF TOTAL FINISHED CLEARANCE, AND HAVE CLEARANCE OF MIN. 21" IN FRONT OF TOILET. TOILETS TO 5E LIMITED TO Lro GALLONS PER FLUSH. • PROVIDE EXHAUST FAN IN KITCHEN AT MIN. 100 GFM AND BATHROOMS AT MIN. 5e GFM. ALL FANS AND DRYER EXHAUST TO 5E VENTED TO OUTSIDE OF RESIDENCE. MIN. lee CRI REMOVE ADD W< AD] RE-GONFh ADD D0 SINK JOI: NO- �T,L (MAIN) FLOOR PLAN Jo ) SCALE: 1/4" = I'-T CITY OF ANACORTES PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT#: BLD-2021-0021 ADDRESS: 5203 Doon Way APPROVED BY: SUBJECT TO FIELD INSPECTION. APPROVED PL S SHALL NOT BE ALTERED WITHOUT AUTHC1R17A ON. FLOOR PLAN LEGEND EXISTING WALL NEW WALL OR FRAMING --------------- ___________ ______ OLD/REMOVED WALL EXHAUST FAN Ojd design JIM DUNLAP (360) 982-0535 JIM@JDDESIGNDRAFTING.COM u I I I I I I I I I I I I I I I I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I I I I I I I I I I I I I I I I I I I � I I I I I I I I I I I � I I I I I I F7 � I I I I I STORAGE DN�R I I I I I I I I I I I I I I I I I I ADD SITTING BENCHES LOFT � Q � Q To X w (OPEN BELOW) I I I I I I LOFT FLOOR PLAN SCALE: 1/4" = 1'-0" EXISTING MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" Ojd design JIM DUNLAP (360) 982-0535 JIM@JDDESIGNDRAFTING.COM