HomeMy WebLinkAboutPermit File BLD-2021-0021 5203 Doon Way (4)u
HIMIZU= MITH REMODEL
5203 DOON WAY
ANACORTES, WASHINGTON
PARCEL I D# P60031
SKYLINE NO 11 LOT 18
PROJECT DESCRIPTION: INTERIOR REMODEL OF 1-1/2 STORY SINGLE
FAMILY RESIDENCE. NOTE: NO CHANGES WILL BE MADE OUTSIDE OF
EXISTING FOOTPRINT.
NOTE: IN THE SECTION OF THE HOUSE WHERE WALL CHANGES ARE
TO BE MADE (IE: KITCHEN/GREAT ROOM AREA) THE ROOF STRUCTURE
IS PRE -MANUFACTURED ROOF TRUSSES. IT IS PRESUMED THERE ARE
NO INTERIOR BEARING WALLS AT THIS SECTION.
BUILDING CODES
CONSTRUCTION WILL COMPLY WITH:
5UILDING ;STRUCTURAL
2015 IRC
MECHANICAL
2015 IRC
PLUM5ING
2015 UPC
ENERGY ; VENTILATION
2015 WSEG
FLOOR PLAN NOTES
• THE FOLLOWING NOTES REFER TO ANY NEW FLOOR
PLAN ELEMENTS.
• WRITTEN DIMENSIONS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. VERIFY ALL DIMENSIONS AND
CONDITIONS IN THE FIELD.
• CONFIRM ALL DOOR, WINDOW, CLOSET, AND ANY
OTHER ROUGH OPENING SIZES WITH OWNER/
CONTRACTOR PRIOR TO WALL CONSTRUCTION.
• ALL WOOD IN CONTACT WITH CONCRETE MUST 5E
PRESSURE TREATED MATERIAL. USE CORROSION
RESISTANT FASTENERS WHEN IN CONTACT WITH
PRESSURE TREATED LUMBER.
• ALL INTERIOR WALLS TO 5E FRAMED WITH 2 X 4
STUDS AT Ifo° O.G. AND SHEATHED WITH 1/2' GYPSUM
WALL50ARD UNLESS NOTED OTHERWISE.
• ALL GLASS TO HAVE LOW E (0.40) GLAZING. GLAZING
IN HAZARDOUS LOCATIONS TO 5E TEMPERED PER
IRC SECTION R305. SEE R305.4 FOR DEFINITION OF
HAZARDOUS AREAS.
• ALL SHOWER AREAS TO 5E FINISHED WITH A SMOOTH,
HARD I NON -ABSORBENT MATERIAL TO MIN. 12`
A50VE DRAIN INLET. THIS MATERIAL TO 5E
INSTALLED OVER WATER RESISTANT PLASTER
BOARD.
• TOILETS TO 5E LOCATED IN AREA WITH MIN. 3e`
WIDTH OF TOTAL FINISHED CLEARANCE, AND HAVE
CLEARANCE OF MIN. 21" IN FRONT OF TOILET. TOILETS
TO 5E LIMITED TO Lro GALLONS PER FLUSH.
• PROVIDE EXHAUST FAN IN KITCHEN AT MIN. 100 GFM
AND BATHROOMS AT MIN. 5e GFM. ALL FANS AND
DRYER EXHAUST TO 5E VENTED TO OUTSIDE OF
RESIDENCE.
MIN. lee CRI
REMOVE
ADD W<
AD]
RE-GONFh
ADD D0
SINK JOI:
NO-
�T,L (MAIN) FLOOR PLAN
Jo
) SCALE: 1/4" = I'-T
CITY OF ANACORTES
PLANNING AND BUILDING DEPT:
APPROVED PLANS
REVIEWED FOR CODE COMPLIANCE
PERMIT#: BLD-2021-0021
ADDRESS: 5203 Doon Way
APPROVED BY:
SUBJECT TO FIELD INSPECTION. APPROVED PL S SHALL NOT
BE ALTERED WITHOUT AUTHC1R17A ON.
FLOOR PLAN LEGEND
EXISTING WALL
NEW WALL OR FRAMING
---------------
___________ ______ OLD/REMOVED WALL
EXHAUST FAN
Ojd design
JIM DUNLAP
(360) 982-0535
JIM@JDDESIGNDRAFTING.COM
u
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
— — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — —
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
�
I
I
I
I
I
I
I
I
I
I
I
�
I
I
I
I
I
I
F7
�
I
I
I
I
I
STORAGE
DN�R
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
ADD SITTING BENCHES
LOFT
�
Q
�
Q
To
X
w
(OPEN BELOW)
I
I
I
I
I
I
LOFT FLOOR PLAN
SCALE: 1/4" = 1'-0"
EXISTING MAIN FLOOR PLAN
SCALE: 1/4" = 1'-0"
Ojd design
JIM DUNLAP
(360) 982-0535
JIM@JDDESIGNDRAFTING.COM