Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2021-0021 5203 Doon Way (3)
1l Y o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 _ Office Location: 904 6th Street, Anacortes WA 98821 17 Phone: (360) 293-1901 Residential Building Permit Application Submittal Packet New Single Family Residences (SFR) Duplexes Additions and Remodels (SFR & Duplex) Accessory Dwelling Units Manufactured Homes Residential decks and retaining walls SUBMITTAL CHECKLIST 0 CZ c 3 Residential Building Permit ° R t ¢ � _ 3 o Requirement Checklist i T � 0 @ o Submittal . M H U. *- t7 N "a ON c e "a N 4.. W _QJ H O .0 See pages 2-3 of this handout for information about each 3 v u u W E O cc *'' Qt submittal item listed below. Z c m Q p Cr = U Residential Building Permit Application Form X X X X X ., (FORM BP-1-attached) Structure & Site Information Form X X X X X `v' (FORM BP-2—attached) Mechanical & Plumbing Fixtures Form X X X V' (FORM BP-3—attached) Architectural Plans X X X X X (requirements listed on FORM BP-4 - attached) Stormwater Management Minimum Requirements X Determination X X X (FORM BP-5, attached) X X X X Stormwater Site Plan I Site Plan & Landscape Plans X X X X X (requirements listed on Form BP-6) Structural Plans & Calculations X X X X X A- Energy Code Plans & Forms X X Manufacturer's Specifications/Cut Sheets X N Copy of recorded survey X X X X � Technical Reports X X X X Other Required Permits X X X X X �j Lu ADU Affidavit of Owner Occupancy (signed) X Required Number of Copies and Plan Size Fees • Plan review deposit is taken at time of 2 paper copies of each item above „ Plans must be minimum 11 x 17 , to scale, and legible application submittal. . Permit fees are paid prior to building „ 1 reduced size copy (maximum size 11 X 17 ) of the Site permit issuance. Plan, Floor Plan and complete Building Plans Page 1 of 18 Res. Building Permit Application Submittal Checklist Updated October 10, 2019 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT �4 W V" Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 61h Street, Anacortes WA 98821 ` Phone: (360) 293-1901 Additional details on certain submittal items is proviaea oeiow w CfIZOU1 C „JJtJ" ,o 11 what City staff will be looking for when an application is submitted to the City. FORMS AND PLANS • FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION FORM. Provides key information about your project, including type of permit you are applying for, and property owner, contractor, and contact information. • FORM BP-2: STRUCTURE AND SITE INFORMATION FORM. Provides key information about the proposed structure, including height, floor areas, fire protection proposed, and asks questions about site characteristics that are used to determine whether your project requires any other information or additional permit applications to be submitted. • FORM BP-3: PLUMBING AND MECHANICAL INFORMATION. Form BP-3 provides space for you to fill in fixture information for plumbing and mechanical appliances and equipment that are included as part of your project. • FORM BP-4: ARCHITECTURAL PLAN REQUIREMENTS. Form BP-4 contains a list of all the items required to be shown on Architectural Plans. • FORM BP-5: STORMWATER MANAGEMENT DETERMINATION FORM. Most development within the City of Anacortes that involves disruption of soils, or construction of buildings, streets, parking lots, etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed (grading, vegetation removal), or the amount of hard surface that is created or replaced on a site (building footprint, concrete, asphalt or gravel parking, sidewalk, etc.). Form BP-5 assists you in determining the level of stormwater review (applicable Minimum Requirements) required for your project. • STORMWATER SITE PLAN. The Stormwater Site Plan is the comprehensive report containing all of the technical information and analysis necessary for regulatory agencies to evaluate your project for compliance with stormwater requirements. The level of stormwater review and contents of the Stormwater Site Plan will vary with the type and size of the project, and individual site characteristics. Use Form BP-5 to determine the level of stormwater review and then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Eneineering Department Forms website and provide required submittal items/plans. • FORM BP-6: SITE PLANS & LANDSCAPE PLANS. Form BP-6 contains a list of all the items required to be shown on Site and Landscape Plans. • STRUCTURAL PLANS: Plans prepared and stamped by a State of Washington licensed professional structural engineer drawn at a scale approved by the Building Official clearly indicating the information required by the "Permits" section of the currently adopted International Building Code and Chapter 19.27 RCW (State Building Code Act, Statewide amendments), and City submittal forms including: structural members labeled as to size and spacing as well as bracing, blocking, bridging, special connectors, and anchor bolts; cross-section details, as needed, to show typical foundation, floor, wall, ceiling and roof construction; insulation of walls, floors and roof/ceiling; and details of stairs, fireplaces and special construction, if any. Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 2 of 18 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6tn Street, Anacortes WA 98821 Phone: (360) 293-1901 0 - • STRUCTURAL CALCULATIONS: An analysis of loads, materials, etc., prepared and stamped by a State of Washington licensed professional structural engineer. • ENERGY CODE FORMS: The standard Washington State Energy Office form requesting the information required under Chapter 51-11 WAC detailing building components used to comply with the State Residential or Nonresidential Energy Code, as applicable. • MANUFACTURER'S SPECIFICATIONS/CUT SHEETS: A document that summarized the performance and other technical characteristics of a product, machine, component, material, or subsystem (e.g., a power supply) in sufficient detail that allows the City to determine the product will be incompliance with applicable codes. • COPY OF RECORDED SURVEY. A survey of your property is needed so that conformance with minimum setback requirements and other development standards can been confirmed and verified on site by the inspectors. Property markers must be visible on your property. If they are not at the time an inspection is requested, you may need to have a new survey completed. OTHER SUBMITTALS DETERMINED ON A CASE -BY -CASE BASIS TECHNICAL REPORTS Following is a list of technical reports that will be required to be submitted to the City when certain circumstances exist on or near a site an Applicant is planning on making improvements to. The general triggers for each of the listed technical reports I provided below: A. CRITICAL AREAS REPORTS: In general, Critical Area reports are required when wetlands and/or streams are located on or near a site. Critical area mitigation plans may also be required, depending on the project proposal. See Anacortes Municipal Code Ch. 17.70 for additional information. B. GEOTECHNICAL REPORT: In general, Geotechnical Reports are required when work is proposed on or near slopes in excess of 15% and/or known landslide hazard areas. See Anacortes Municipal Code Ch. 17.70 for additional information. OTHER PERMITS DETERMINED ON A CASE -BY -CASE BASIS OTHER FORMS Following is a list of other permits that could be required in certain circumstances. The general triggers for each of the listed permits is provided below. A. FILL AND GRADE PERMIT: Grading (importing, exporting, and/or moving material on a site) of more than 50 cubic yards and/or if grading modifies the existing flow of stormwater or groundwater. B. RIGHT-OF-WAY PERMIT: A right-of-way permit is required anytime the public right-of-way is disturbed or obstructed in any way by private development or the general public. Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 3of18 Y 0 PLANNING, COMMUNITY, 9, ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 -1cpr: Page left blank intentionally. Res. Building Permit Application Submittal Checklist updated October 10, 2019 Page 4 of 18 NJ y � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT `' Mailing Address: P.D. Box 547, Anacortes, WA 98221 Office Location: 904 6t" Street, Anacortes WA 98821 } ` Phone: (360) 293-1901 1. PROPERTY INFORMATION Project Address (Street, Suite #): 5a-O, cOlu IAJtY Subdivision/Lot #: I Zoning Designation: Ivu- r L-U i I V 9. 2. TYPE OF PROJECT Assessor Parcel Number: r (P 0031 Lot area (size): sq. ft. ❑ New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) El New Duplex ❑ Attached to Primary Unit P Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building ❑ Fence or retaining wall or duplex (new/repair) ❑ Other: Project Summary: 1 V 9 12— i2c5M ODi5L, — f k(' L V. I N G--►g --e PA-) Ff 6 Project Valuation: $ "-fb' + 060 • 00 3. PROPERTY OWNER INFORMATION Name: Phone: -r i.,� J & _Q14.1 AA 1 z 14 / I SD Ai 'rM (1�- Address (Street, City, State, Zip): lit K441-RV 0 f Email Address: I �� Ni,. 9. i1v 512�'w1 � � n� �= C e � 4. CONTRACTOR INFORMATION Name:* 0 Phone: Contractor's Business Licenses State Lie nse #: City License #: *Ali contractors & Subcontractors must have a valid City of Anacortes business license prior to doing work in the Expiration Date: Expiration Date: City. T 90 d-og Z City, Address (Str t,State, � Email Address: ©_p ''s l(3a S VC, ` act `• L S. CONTACT PERSON Select one person the city will contact for anything related to this project: Name: Address (Street, City, State, Zip): ( c', -)A7 K`� SA ilyi cLC —Ire-5 , L.v J2v- q'502-1 Applicant ❑ Property owner N Contractor Phone: 3L'R0 - Email Address: jC.. 6�i`�,nt? °�ii..r'� �c���ey�v-� art° 1- C..��v►' Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 5 of 18 �,-t y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 5 Phone: (360) 293-1901 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write "no lenders" on the Nam, e Line below. `_ Name:'i—T f �d-e— &4,,L IN,4 ( Phone: Z55— 5T?— 5qS Address (Street, City, State, Zip): Email Address: , t,�ix j Gt b i n -Q s 4e- OD �� . 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean ( the application has been deemed technically complete and sufficient for staff review. I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. i� I understand and acknowledge that I could be responsible for providing as -built drawings (on paper or electronically) as part of the project's certificate of occupancy process. I understand and acknowledge that Special Inspections could be required as part of my project, and ° if needed I will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am r " completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. I understand that if permits are reviewed concurrently such as design review, site plan, traffic concurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. L.+ I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. l� 1 Signatur' Date Printed Name Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 6 of 18 ti PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT ' Mailing Address: P.O. Box 547, Anacortes, WA 98221 JPXJWFP"P Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 9 .: •' AND INFORMATION 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: ��- a 0 3 0 O Af ir2^S PARCEL NUMBER Sn0 2. DETAILED PROPOSED STRUCTURE INFORMATION Complete the following information as it relates to your project. Mark items that are not applicable with "N/A". Structure height: % AREA SQUARE FOOTAGE OCCUPANCY GROUP CONSTRUCTION TYPE OCCUPANT LOAD 15t Floor: 2"d Floor: 3rd Floor: Basement: Garage:Z Total deck: Total porch: Other: EOther:tEE : 3. QUESTIONS ABOUT THE PROPOSED STRUCTURE Is a fire sprinkler system being installed? ❑ YES"NO Is a monitored fire alarm being installed? ❑ YES ❑` NO Are retaining wall(s) being built? ❑ YES aNO Are structural plans required? ❑ YES DINO 4. PROJECT SITE INFORMATION A. Is work within the City's right-of-way proposed? If yes, you will be required to submit a right-of-way permit application. If you have already submitted a ROW permit, list the permit number here: ❑ YES [a NO B. Is the property located in a flood zone? If yes, list the flood zone designation: ❑ YES 0'N0 C. Are there slopes in excess of 15% on or abutting the site? If yes, a geotechnical report will likely need to be submitted. ❑ YES NO Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 7 of 18 y r}� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 N, Phone: (360) 293-1901 OpR , D. Are there critical areas or buffers on or abutting (within 300-feet of) the �YES ❑ NO project site? If yes, a critical report will likely need to be syubmitted. {areas it to �i If — � VV E. Is the lot less than 5,000 sq. ft. in area? ❑ YES LINO If yes, your site and building will need to comply with the standards in AMC 19.43.010. C. F. Is your project involving an accessory dwelling unit? ❑ YES DINO If yes, your site and building will need to comply with the standards in AMC 19.47. G. Will more than 2-acres be cleared and/or more than 5,000 board feet ❑ YES CDINO (about 1 log truck load) of timber be harvested? If so you may need to obtain a forest practices permit from DNR. H. Is this project subject to the SEPA process? If yes, you will be required to ❑"`YES ❑ NO submit a SEPA checklist. If you have already completed the SEPA process, list the permit number here: itJ , lv— — &L- - 0,e" t`Z- Q AJ 5. REQUIRED SIGNATURE I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. IS 2� t Signature ° Date Printed Name Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 8 of 18 8,V y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 MECHANICAL Equipment Type: Appliance/Equipment Information (new and relocated): Total #: Furnace: Gas #: Elec #: BTU: Other #: Wall Heater: Gas #: Elec #: Other: #: Location(s): Gas Water #: Location(s): Heat Pump: Air Conditioning: Elec #: Elec #: Other #: Capacity: Other #: Capacity: Radiant /Hydronic Gas #: Bath #: Elec #: Other: #: Location(s}: Laundry#: Other: Exhaust Fans: Range Hood: #: [ Location(s): IL r Fireplace: Clothes Dryer & Duct: Gas #: j Gas #: Elec #: Other: #: Location(s): Elec #: Other: #: Location(s): Stove/Range/Oven: Gas Piping/ Outlet(s): Boiler Gas #: l #: Gas #: Elec #: Other: #: Location(s): Location(s): Elec #: BTUs: Location(s): ' Other: #: Location(s): TOTAL MECHANICAL OUTLETS: ' PLUMBING Fixture Type (new and relocated): Total #: Fixture Type (new and relocated): Total #: Water Closet (Toilet): Refrigerator water supply (for water/ice Kitchen Sink: Pressure Reduction Valve/Pressure Regulator: Utility Sink: Tub: Water Service Line: Water Piping: Hand Sink: Clothes Washer: Shower: C Electric Water Heater: Tank -less? Yes ❑ Dishwasher: Backflow Prevention Assembly: Hose Bib: Other: TOTAL PLUMBING FIXTURES: Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 9 of 18 t y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office location: 904 6th Street, Anacortes WA 98821 ` - Phone: (360) 293-1901 . N0 REQUIREMENTSFORM BP-4: ARCHITECTURAL PLAN 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: D 0 N Ltl PARCEL NUMBERS) 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant architectural plans. Please to sure they contain each of the listed items. To the right of the check the plans you wish to submit make Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11" x 17" and drawn in an architectural scale. 4,000 square feet or larger are required to be prepared and • Architectural plans for structures stamped by an architect licensed in the State of Washington. • Structural plans must be stamped by a structural engineer licensed in the state of Washington. 3. REQUIREMENTS FOR ALL ARCHITECTURAL PLANS COMPLETE REQUIREMENTS PAGE # ON YOUR PLANS 7 Cover (or 1st page) must include: • Site address • Parcel number-- V • Lot number (if applicable) • Lot size • Lot coverage • % impervious surface coverage - Floor plans with existing (if applicable) and proposed building layout with square footages and with the use of each room/area labeled. Window and door sizes labeled and window ventilation area. Commercial, ' Multi -Family, and Mixed -Use Structures must also include door=dow schedules. Plumbing, duct, and electrical layout. Penetration protection must be shown. N j ; Opening headers, size, and material. Cross section details, showing typical foundation, floor, wall, ceiling and roof IV IA-- construction and insulation. Structural members labeled as to size and spacing as well as bracing, blocking, A bridging, special connectors, and anchor bolts. €U 1 Details documenting energy code compliance. r,j Exterior building elevations demonstrating compliance with applicable structure type design standards (small lot, duplex, or ADU) and maximum building height Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 10 of 18 y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT PqWW Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 1co , Phone: (360) 293-1901 Building height (see AMC 19.42.120 for measurement methods, exceptions and modifications). • Label the building height at the highest point of the structure from the average of the natural topography at the foundation at the front of the building. • Label the average elevation of the natural topography at the front of the building. • Label the elevation at the center of all exterior walls of the proposed building. • For ADUs only, include elevations demonstrating compliance with the height/setback plane (see AMC 19.47.030(C)(6)). t Special details as needed (i.e., stairs, fireplaces, special construction). ,,,, A- Insulation and insulation values of wails, slab, floors, and roof/ceiling. i (y- Existing and proposed grades with slope of lot shown. Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 11 of 18 SHIMIZU-SMITH REMODEL 5203 DOON WAY ANACORTES, WASHINGTON PARCEL ID# P60031 SKYLINE NO 11 LOT 18 PROJECT DESCRIPTION: INTERIOR REMODEL OF 1-1/2 STORY SINGLE FAMILY RESIDENCE. NOTE: NO CHANGES WILL BE MADE OUTSIDE OF r EXISTING FOOTPRINT. NOTE: IN THE SECTION OF THE HOUSE WHERE WALL CHANGES ARE TO BE MADE (IE: KITCHEN/GREAT ROOM AREA) THE ROOF STRUCTURE MIN, lee`FMEXHAUST FAN IS PRE -MANUFACTURED ROOF TRUSSES. IT IS PRESUMED THERE ARE PRIMARY NO INTERIOR BEARING WALLS AT THIS SECTION. eeDRooM i U, ZONING DESIGNATION: R2 Y 9 REMOVE tJNEN CLOSET ADD WALL AND DOOR 0. ADD BARN DOOR ` BUILDING CODES 969 BARN DR CONSTRUCTION WILL COMPLY W TH; BUILDING Q STRUCTURAL 2 151RC U�LO.E RE-CgJFIGURE CLOSETMECHANCAL 2—IRC2015 UPENERGY Q VENTILATION 2015 WSEC � LAUNDRY _ FLOOR PLAN NOTES • THE FOLLOWING NOTES REFER TO ANY NEW FLOOR PLAN ELEMENTS. • WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS, VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD • CONFIRM ALL DOOR, WINDOW, CLOSET, AND ANY OTHER ROUGH OPENING SIZES WITH OWN-1CONTRACTOR PRIOR TO WALL CONSTRUCTION • ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED MATERIAL USE CORROSION RESISTANT FASTENERS WHEN IN CONTACT WITH PRESSURE TREATED WMBER. • Al__ INTERIOR WALLS TO BE FRAMED WITH 2 X 4 STUDS AT 16' O,C, AND SHEATHED WITH 112' GYPSUM WALLBOARD UNLESS NOTED OTHERWISE. • Al__ GLA.. TO HAVE LOW E (—) GLA9NG. GLAZING IN HAZARDOUS LOCATIONS TO BE TEMPERED PER IRC SECTION R3 SEE R3RF1 FOR DEFINITION OF HAZARDOUS AREAS. • ALL SHOWER AREAS TO BE FINISHED WITH A SMOOTH, HARD Q NON -ABSORBENT MATERIAL TO MIN, T2" ABOVE DRAIN INLET. THIS MATERIAL TO 5E INSTALLED OVER WATER RESISTANT PLASTER BOARD. • TOLET9 TO BE LOCATED IN AREA WITH MIN. S.- WIDTH OF TOTAL FINSHED CLEARANCE, AND HAVE CLEARANCE OF MIN 21' IN FRONT G TOLET. TOILETS TO BE LIMITED TO 1.6 GALLONS PER 1W9H. • PROVIDE EXHAUST FAN IN KITCHEN AT MN IB® CfM AND BATHROOMS AT MIN 50 CFM. ALL FANS AND DRYER EXHAUST TO BE VENTED TO OUTSIDE OF RESIDENCE. VICINITY MAP ADD DCUGLE VANITY Q OPEN SHELVES {BEAN 0 G A99 SINK JCTSTS FOR PLUSH-CUO O NORB 9HCWER FT P- II II II II it I II II II II II __ II II it II II II II GARAGE II II II II II r____ ------------ r__ _-r I III I I I III I I I III I I III I I II I I I III I I I III I I W DN5R REMOVE HEARTH INSTALL GAS INSERT FIREPLACE GREAT ROOM 'm REMOVE WALL. 5' OPENNG FOR FUTURE 7_- DcuBLE DooR CENTERED 0 ENTRY �n REMovE DOOR tH 7 OI \ / (� OFFICE REMOVE HALLWAY WALL5 Q DOORS 9EDROOM2 MUSIC ROOM GAS FIREPLACE ((+-)��?��OSED'M�AIN) FLOOR PLAN FLOOR PLAN LEGEND EX.NG WALL I NEW WALL OR FRAMING EXHAUST FAN (ID jd design JIM DUNLAP (560) '02-0535 J IMOJDDESI G N DRAF TIN G. COM LOFT FLOOR PLAN IXISTING MAIN FLOOR PLAN vjd design JIM DUNLAP (360) 9152-0535 J I M OJDDESIGNDRAF TING. C OM