HomeMy WebLinkAboutDOC-2019-Revised First Floor Plan -FLOOR PLAN NOTE&
1, VIDE BARRIER FREE SIG E AT ALL ADA RESTROOMS
CONFIRM ALL ROUGH OPENINGS DOORS AND WINDOWS PRIOR TO
FRAMING AND ORDERING.
3. CONFIRM ALL FINISHES W/ OWNER AN CONTRAC
TO ORDERING.
4_ CONTRACTOR TO COORDINATE BUILDING AL RM/SECURITY
SYSTEM W/ OWNER PRIOR TO DRYWALL INSTALLATION.
5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL CASEWORK FOR
APPROVAL BY ARCHITECT/ OWNER PRIOR TO CONSTRUCTION:
6. SOUND INSULATE ALL WALLS TYP_ THROUGH -OUT.
7. SEE WALL TYPE DETAILS 1-20/A-7.1 AND 22-37/A-7.1A
& HEAT FOR THE CORE SPACE WILL BE GAS PACK UNITS ON THE ROOF
W/ DIFFUSERS AS REQUIRED. COORDINATE LOCATIONS OF DIFFUSERS
AS REQUIRED WITH LIGHTING, REFER TO MECHANICAL DRAWINGS TYP.
THE MOTEL UNITS WILL BE HEATED BY P-TAC ELECTRIC HEATERS TYP.
PER MECHANICAL DRAWINGS TYP,
9. ALL RESTROOMS TO HAVE GREEN GWB TYPICAL ALL WALLS AND CEILING.
10. VENT HOT WATER TANK OUTSIDE AS REQUIRED. PROVIDE RELIEF VALVE
PAN, AND SEISMIC STRAPPING AS REQUIRED.
11, ALL WINDOWS ARE TO RECEIVE SOLID SURFACE SILL
12. DUCTS MAY NOT PENETRATE FIRE BARRIER BETWEEN UNITS WITHOUT
DAMPERS PER IBC 717.5.2. (NOTED AT INTERCONNECTED BATH FANS)
1�
1. 3'-0'
bD
n - CD -
p
2.0' 8' CMU
COLUMN
WRAP
CV'
6X6 HSS
-4.
N
I
(Dc)
0
c
-41 'd- 8' CMU
COLUMN
WRAP
0
cV 1
PARKING
119
21'-10'
EXIT PLAN NOTES:
1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-0' PER
TABLE 1014.3 (OK)
2. OVERALL EXIT TRAVEL DISTANCE < 200'-0' FOR t10151.
00Ca ITH
SPRINKLERS PER TABLE 1016.2 (OK)
3. (7) EXITS PROVIDED AND (3) ARE REQUIRED PER CIE WE HAVE
BETWEEN 501 AND 1000 OCCUPANT LOAD. (OK)
4. WHERE 2 EXITS ARE REQUIRED WE HAVE MET THE REQUIREMENT THAT
THE EXITS DOORS ARE GREATER THAN 1/3 THE DIAGONAL DISTANCE
APART OF THE OCCUPANT AREA SERVED PER 1015.2-1 EXCEPTION 2, (OK)
EGRESS WIDTH PER OCCUPANT SERVED 638 OCCUPANTS (PER COVER
SHEET) (.20) INCHES PER OCCUPANT (PER TABLE xxx WITH (I-2)
OCCUPANCIES WITH SPRINKLER SYSTEM ) 638 X (.20) 128 INCHES.
WE PROVIDED (7) EXIT DOORS (46+46+46+46+46+46+46) 322 INCHES
WHICH IS > 128 INCHES (OK)
INSTALL EXIT LIGHTS & FIRE EXTINGUISHERS SHOWN ON PLAN AND
AS DIRECTED BY THE FIRE MARSHALL
m
20'-11r I
FLOOR PLAN LEGEND
EXIT
DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE W/ BATTERY
�
SEE WALL TYPES DETAILS ON SHEET A-6,1
BACKUP
BUILDING DOWN SPOUT LOCATIONS
COMBINATION EXIT SIGN/EMERGENCY LIGHTING WITH
o DS
6' m FLOOR DRAIN. SLOPE FLOOR TO DRAIN
EXIT
BATTERY BACKUP HARDWARE
O FD
FREEZE PROOF HOSE BIB. PER MECHANICAL
EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE
+ H �
STRUCTRUAL POST OR BUNDLED STUDS. OR HSS
❑FE
2A 1OBC SEMI -RECESSED FIRE EXTINGUISHER SEE
El [3
SIZE PER STRUCTURAL
FLOOR PLAN SHEETS FOR LOCATIONS
Ox
DOOR NUMBER SEE SHEET A-2,5 FOR SCHEDULE
OR
CLASS I STANDPIPE IN STAIR LANDINGS
AND ROOF AS REQ'D BY FIRE MARSHALL
OWINDOW
NUMBER SEE SHEET A-2.5 FOR SCHEDULE
AND 905 OF THE IBC
X X X
ROOM FINISH TAG SEE SHEET A-2.6 FOR SCHEDULE
I
CD'
Lei
4' CMU VENEER W/ REINFORCEMENT
(1) HOUR STRUCTURAL/ BEARING WALL - 2 X 6 WD FRAMED
WALLS 0 16' O,C: W/ EXTERIOR SIDING PER ELEVATIONS,
- 0/ TYVEK COMMERCICAL WRAP 0/ 1/2' EXT. SHEATHING PER STRUCT. W/ R-21
BATT INSULATION W/ INTERIOR V.B. W/ (1) LAYER 5/8' TYPE 'X' GWB
LEVEL 4 FINISH, PNT.
0 INTERIOR WALLS TO BE 2 X _ WD FRAMING
0 16' O.C. W/ 5/8' TYPE 'X' GWB BOTH SIDES, TAPED. MUDDED.
AND SANDED, LEVEL 4 FINISH, PNT. BOTH SIDES W/ SOUND BATT
INSULATION 0 COMMON SPACES ONLY. INTERIOR OFUNITS NO INSULATION
FRAME ALL WALLS TO BOTTOM OF (1) HOUR CLG ASSEMBLY CLG GWB
TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE
CAULK/ SEAL GWB TO CLG, SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
0 2-HOUR WALL AT STAIR AND ELEVATOR ENCLOSURES. (2) LAYERS I' 'X' GWB
EA. SIDE OF 2X6 WOOD STUDS 0 16' O.C, SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
(1/21 HOUR UNIT SEPARATION WALLS TO BE 2 X 6 P.T. WD SILL PLATE
0 W/ 2X4 STUDS 0 8' O.C. STAGGERED EA. SIDE W/ R-21 BATT
INSULATION W/ ON 1/2' RC CHANNEL 5/8' TYPE 'X' GWB BOTH SIDES.
LEVEL 4 FINISH, PNT. BOTH SIDES TYP. FRAME ALL WALLS
TO BOTTOM OF (1) HOUR CEILING ASSEMBLY U.N.O. CLG GWB TO BE
INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB, FIRE CAULK/
SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL
LOCATIONS AND PLYWOOD SHEATHING LOCATIONS
l3 i -
7 95'-0' -4.1 8 9 10 11
73'- 21 PROVIDE POWER FOR
DS AUTO/OPEN PUSH BUTTONS
_ _ _ _ _ 1s _ AT VESTIBULE DOORS
13'-4' -6• BOTH SETS ADJUST 38'-10r
I
E CONC.
O SIDEWALK
SLOPE AWAY
VESTIBULE -6r 11'-8' 9'-21'
100 x
-6.
AUTO EN -4.
PISH BUTTON 2'-2r 3 -W
1 O DS O HB H1 DS C
O
I
O EXIT O F I OR
LI Y,
-1 STAIR
111 41-0'
I I
LOBBY 0 I I SEATING
10
101 � I 110
GAS FIREPLACE V.Ta .
WITH MANTLE AND I
I I HEARTH SURROUND I
1
I I I
I cof ee
I I
0
UP I
- - _ 4'-0'
0 R R.0 F.D, CD l
13'-5'
10'-1'
12
0)
ELECTRICAL ; I
ROOM
112 O
4
SWBD.
O
HWT HWT
MECHANICAL
113 F.Do O
SPRINK,
�n
nuuu d-.
m llll _'
uulill
uumi _ C
I -4.1
10,
CJ
115 Lo
1 L
m
c -
o �
:,. '5; x
DIW 6cq*%Q N
O x
Fu "t
PREP I ALUMI UM F ENCING
SYSTEM-0 W/ TEMPERED
116 �GLAZING ° o
' II I II 0
W
O HOT o a�
11X O TUB 11
1 DRYER I I I I I VaTaOa H B 118 -6.3 -
o
F.O.LC. U
I I I CU
.
II I II
Li
Q V.T.O.81 CMU coa
FpR k�
COLUMN I 0 } DRYER I I I I I I I I RIEF PROVIDE POWER, 8' CMU '�� 1� Y Oo
WRAP I o FA.LC_ G
C7 / OR I DISCONNECT AND DRAIN COLUMN (�
- - S - - - DS O O DS -� - - - ' DSI_ - - - - - - �� ,� N�°4coRS?
H - - - - H1- - - - / 5'-0' I �roFrE.n Se�
3'_0' I 2 g'_g' I 2'-5�' 6'-6' I 6' 5�' 6'-0' I ALUMINUM FENCING
6X6 HSS t6.0) �_ � - � � - SYSTEM W/ TEMPERS 6X6 HSS
13 7� 27 7T' 6 -9 16 5 GLAZING
E
FIRST F 1 2 PLAN 4 g4.7 5 6 6.97 °, 88. � 9 '9.9 410.9 11 12
00
SCALE: 1/4'=1'-0' -
N
c9 RE -1 109 FLOOR �-'=r7
T
0 SINK
RECESSED
15
9'4' 9'-2r 2'-10r 16'-3r W 0 8'-2' 4'-8' 6'-2f
_ `" O HALL 19 rn O
7
iti�lt
66'-9' ' ' 3'6' 3'- 114 12'-6' 6'-9'
R
cV
UF 11 107
1 1 WASHER
F.O�LC.
I F.D.
�? I C, 10
o
F SHER
I I
I
I
IIBREAKFAST
108
Y
Y
Plumbing to comply
with UPC. Provide
plumbing
description/layout
prior to inspection.
16
FLOOR
SINK
RECESSED
CARLETTI ARCHITECTS P.S.
architecture, planning, interior design
116 EAST FIR STREET
SUITE A
MOUNT VERNON, WA. 98273
Phone: R60
424-0394
Fax: 424-5726
6429
REG STERED
HITECT
IPETER TTI
STATE 0 WASHINGTON
SALISH INN
907 30TH STREET
ANACORTES, WA 98221
EK TERA ASARA, LLC
905 20TH STREET
ANACORTES, WA 98211
CONTACT: KULJIT SHOKER
EMAIL: JAS.SH037@GMAIL.COM
PHONE: 360-770-3701
[rA E
�M R
CONSTRUCTION
360.354.3500
19-312
REVISIONS:
6/14/19 PERMIT SUBMITTAL
Al 8/27/19 PERMIT REVISIONS
2 9/16/19 PERMIT REVISIONS
SHEET TITLE:
FIRST FLOOR PLAN
PJC
PROJECT ARCHITECT:
PJC
DRAWN BY:
PJC
CHECKED BY:
02/08/19
DATE
19-312.DWG
COMPUTER FILE NAME
o
COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.