HomeMy WebLinkAboutDOC-2021-Revised Second Floor Plan -FLOOR PLAN NOTES. 1. PROVIDE BARRIER FREE SIGNAGE AT ALL ADA RESTROOMS 2. CONFIRM ALL ROUGH OPENINGS FOR DOORS AND WINDOWS PRIOR TO FRAMING AND ORDERING, 3. CONFIRM ALL FINISHES W/ OWNER AND CONTRACTOR PRIOR TO ORDERING 4. CONTRACTOR TO COORDINATE BUILDING ALARM/SECURITY SYSTEM W/ OWNER PRIOR TO DRYWALL INSTALLATION. 5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL CASEWORK FOR APPROVAL BY ARCHITECT/ OWNER PRIOR TO CONSTRUCTION. 6. SOUND INSULATE ALL WALLS TYP, THROUGH -OUT, 7, SEE WALL TYPE DETAILS 1-20/A-7.1 AND 22-37/A-7.1A 8" HEAT FOR THE CORE SPACE WILL BE GAS PACK UNITS ON THE ROOF W/ DIFFUSERS AS REQUIRED. COORDINATE LOCATIONS OF DIFFUSERS AS REQUIRED WITH LIGHTING. REFER TO MECHANICAL DRAWINGS TYP: THE MOTEL UNITS WILL BE HEATED BY P-TAC ELECTRIC HEATERS TYP. PER MECHANICAL DRAWINGS TYP, 9, ALL RESTROOMS TO HAVE GREEN GWB TYPICAL ALL WALLS AND CEILING. 10, VENT HOT WATER TANK OUTSIDE AS REQUIRED. PROVIDE RELIEF VALVE PAN. AND SEISMIC STRAPPING AS REQUIRED. 11. ALL WINDOWS ARE TO RECEIVE SOLID SURFACE SILL 12. DUCTS MAY NOT PENETRATE FIRE BARRIER BETWEEN UNITS WITHOUT DAMPERS PER IBC 717.5.2. (NOTED AT INTERCONNECTED BATH FANS) =3= 0 d- 0 N 0 N C4 1� D2 3 2'-6' :.2'-9r F1i 0 d- DS II I 25 �II NIT UNIT o <a>Lll 2 A 202 [= _ p F REF , 24 R F u \ n / � � HOUS216EEPING UNIT �I V V 3'-7r 2'-7r 4'-2 ' rC222'-4' 5'-4' O 77 C EXIT PLAN NOTES; 1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL -, 75'-0' PER TABLE 1014.3 (OK) 2, OVERALL EXIT TRAVEL DISTANCE < 200'-0' FOR (R-1) OCC: WITH SPRINKLERS PER TABLE 1016.2 (OK) 3. (7) EXITS PROVIDED AND (3) ARE REQUIRED PER 1015.1:1, SINCE WE HAVE BETWEEN 501 AND 1000 OCCUPANT LOAD. (OK) 4. WHERE 2 EXITS ARE REQUIRED WE HAVE MET THE REQUIREMENT THAT THE EXITS DOORS ARE GREATER THAN 1/3 THE DIAGONAL DISTANCE APART OF THE OCCUPANT AREA SERVED PER 1015.2.1 EXCEPTION 2. (OK) 5. EGRESS WIDTH PER OCCUPANT SERVED 638 OCCUPANTS (PER COVER SHEET) (.20) INCHES PER OCCUPANT (PER TABLE xxx WITH (I-2) OCCUPANCIES WITH SPRINKLER SYSTEM ) 638 X (.20) a 128 INCHES. WE PROVIDED (7) EXIT DOORS (46+46+46+46+46+46+46) 322 INCHES WHICH IS > 128 INCHES (OK) 6. INSTALL EXIT LIGHTS & FIRE EXTINGUISHERS SHOWN ON PLAN AND AS DIRECTED BY THE FIRE MARSHALL FLOOR PLAN LEGEND EX TI DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE W/ BATTERY � SEE WALL TYPES DETAILS ON SHEET A-6.1 BACKUP BUILDING DOWN SPOUT LOCATIONS COMBINATION EXIT SIGN/EMERGENCY LIGHTING WITH DS 6' m FLOOR DRAIN. SLOPE FLOOR TO DRAIN EXIT BATTERY BACKUP HARDWARE 0 FD FREEZE PROOF HOSE BIB, PER MECHANICAL EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE +HB STRUCTRUAL POST OR BUNDLED STUDS. OR HSS ❑FE 2A 1OBC SEMI -RECESSED FIRE EXTINGUISHER SEE ❑ ❑ SIZE PER STRUCTURAL FLOOR PLAN SHEETS FOR LOCATIONS Ox DOOR NUMBER SEE SHEET A-2.5 FOR SCHEDULE ®R CLASS I STANDPIPE IN STAIR LANDINGS AND ROOF AS REQ'D BY FIRE MARSHALL OWINDOW NUMBER SEE SHEET A-2,5 FOR SCHEDULE AND 905 OF THE IBC X X X ROOM FINISH TAG SEE SHEET A-2.6 FOR SCHEDULE 4 5 6 7 98'-0' 6-2' v 8'-1'00 4'-3� COORD. LOCATION OF MINI PLIT HEAD AND CONDIINSER AN HEAL DRYER VENT AS REQUIRED BY ELEV. SU PLIER TO OUTSIDE POST DOOR 'ELE ATOR EQ IPMEN E _4 -4. ROOM' El 4' CMU VENEER W/ REINFORCEMENT (1) HOUR STRUCTURAL/ BEARING WALL - 2 X 6 WD FRAMED WALLS 0 16' O.C, W/ EXTERIOR SIDING PER ELEVATIONS, - 0/ TYVEK COMMERCICAL WRAP 0/ 1/2' EXT. SHEATHING PER STRUCT. W/ R-21 BATT INSULATION W/ INTERIOR V.B. W/ (1) LAYER 5/8' TYPE 'X' GWB LEVEL 4 FINISH, PNT, 0 INTERIOR WALLS TO BE 2 X _ WD FRAMING 0 16' O.C. W/ 5/8' TYPE 'X' GWB BOTH SIDES, TAPED, MUDDED, AND SANDED. LEVEL 4 FINISH. PNT. BOTH SIDES W/ SOUND BATT INSULATION 0 COMMON SPACES ONLY. INTERIOR OFUNITS NO INSULATION FRAME ALL WALLS TO BOTTOM OF (1) HOUR CLG ASSEMBLY CLG GWB TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE CAULK/ SEAL GWB TO CLG. SEE STRUCTURAL FOR SHEARWALL LOCATIONS AND PLYWOOD SHEATHING LOCATIONS 0 2-HOUR WALL AT STAIR AND ELEVATOR ENCLOSURES. (2) LAYERS I' 'X' GWB EA. SIDE OF 2X6 WOOD STUDS 0 16' O,C. SEE STRUCTURAL FOR SHEARWALL LOCATIONS AND PLYWOOD SHEATHING LOCATIONS (1/2) HOUR UNIT SEPARATION WALLS TO BE 2 X 6 P.T. WD SILL PLATE 0 W/ 2X4 STUDS 0 8' O.C. STAGGERED EA. SIDE W/ R-21 BATT INSULATION W/ ON 1/2' RC CHANNEL 5/8' TYPE 'X' GWB BOTH SIDES, LEVEL 4 FINISH, PNT. BOTH SIDES TYP. FRAME ALL WALLS TO BOTTOM OF (1) HOUR CEILING ASSEMBLY U.N.O. CLG GWB TO BE INSTALLED TO WALL TOP PLATE PRIOR TO WALL GWB. FIRE CAULK/ SEAL GWB TO CLG, SEE STRUCTURAL FOR SHEARWALL LOCATIONS AND PLYWOOD SHEATHING LOCATIONS 2'-7r �I I 5 3 'd- I� n I I UNIT I I 204 5'-01' 2'-7' v 4'-2REF I � I UNIT R-EF� 205 2'-4'le I I U ® - - ® ® UP `��6 DN. 20 8'-6' o o . STAIR 36 d- 41 8'-8' 44 47 d- O 219 TO O GW o BATH 37 a I \ BATH a BATH BATH( 201E BATH \ I i; 203B -2 205B 26 :-2o2B `�I ELEV ��� ;� - F 0 2o4B 0 0.1 n in 40 ��zo I 43 4;): � 49 :,N EXIT .4- `t ® 39 9 �- 42 ® 48 N FE O O 45 O _ - - - - - - 4'-6 ' 4-11 ' 6'-10�' 9'-9� 4'-0' S'-3 ' 7'-Or 7'-3r 5'-0J' 5'-3r 6'-9�' 4'-5' 4'-4' W LL BATH 4'-3� 5'-24' 6'-10�' 3'-11� 4'-9f 10'-7r' 1 21 5'-Or 212B 72 O N 71 68 - -' W/d W/d ELEV. EQUIP. ODS 215 ;ND d- GU LAY 7'-4' 23 �j I 69 FEN EXIT - 73 � 0 BATH -1 211 B 1 I N 4'-8 3 -9 4 -3 STAIRS 213 BATH - UNIT o 7o 4'-0' F] 4'-3' 21oB 212 d- I ® UP DN. O 66 >\ REF NIT 2'_7e 5'-1 ' 13'-1�' RE 211 UNIT-B.F d- I 210 r.rr /< I d- d- d- I 0 0 0 DW 0 REF O s2 ATH o N 2068 5 -3 6 -10 7 -0 5 -1 4 -4r 3,_ 6e 2 -9�' QF -7 6'_ 3� 1 O 62 � I 10�0 co 63 ® 59 54 - FI"� i O 660 �Oi 0'-1 ' ATH BATH 011 209E 208E UZZI TUB W/ TILED c 0 SURROUND PREFAB E STALL W/ N p 64 61 p U207 AT�PLASS DOOR Ili" - 5'-0' UNIT 2'-7' L 3'-11 - 209 UNIT �,,, 57 - 8'-3r v 208 I Ili REF REF d- 58 L EDRoo 2o7c �„ 2'-0' ELECTRIC FIREPLA DECK p W/ MANTLE AND HEARTH SURROUND R I S --- ---- DS O DS DS DS N ON C M I 2'-9�' M s.o 3'-1�' H1 M 2'-6' 2'-9�' M � 7 I 5 -0 \031- 4 -1 13'-2e 20'-4e 16'-1' 11'-7e 12'40 -61' 10'-0' 14'-2' 98'-0' 1 2 4 2.9 3 4 4.7 5 6 6. j77 °, 8 8. 9 9.9 4 10. 11 12 SECON1) FLC0R PLAN SCALE; 1/4'=1'-0' _ n CARLETTI ARCHITECTS P.S. architecture, planning, interior design 116 EAST FIR STREET SUITE A MOUNT VERNON, WA. 98273 Phone: R60 60� 424-0394 Fax: 424-5726 6429 REG STERED HITECT IPETER TTI STATE 0 WASHINGTON SALISH INN 907 30TH STREET ANACORTES, WA 98221 EK TERA ASARA, LLC 905 20TH STREET ANACORTES, WA 98211 CONTACT: KULJIT SHOKER EMAIL: JAS.SH037eGMAILCOM PHONE. 360-770-3701 ERrA CONSTRUCTION 360.354.3500 MB 19-312 Stair landing as r NUj�U I INUIVIDCI�: drawn meets the requirements of 2015 IBC 1011.6. REVISIONS: 6/14/19 PERMIT SUBMITTAL 8/27/19 PERMIT REVISIONS 5/14/21 RECORD DWG STAIRS C SHEET TITLE: SECOND FLOOR PLAN F CODE �0 y 0 PJC PROJECT ARCHITECT: PJC 4COg� ��O DRAWN BY: G �To FrEL���� P J C CHECKED BYe __�L 02/08/19 H DATE 19-312.DWG COMPUTER FILE NAME COPYRIGHT 2019 CARLETTI ARCHITECTS. P.S.