Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2023-0090 1316 10th Street
�T } Q City of Anacortes Invoice/Permit#: BLD-2023-0090 904 6th Street Applied date: 02/14/2023 P.O.Box 547 Issue date: 02/14/2023 Anacortes, WA 98221-0547 Expire date: 08/12/2024 -1901 (360) 293 0��. Job Address: 1316 10TH ST Permit Type: Mechanical Permit ANACORTES WA 98221-1902 Project: APN: P55614 Remarks: Install a gas tankless water heater. Owner: BRENT&MARGUERITE LADUE Contractor: CPI PLUMBING HEATING&CNG LLC Address: 9812 SUNSET DR Address: 1900 RAILROAD AVE LA CONNER WA 98257 MOUNT VERNON WA 98273-4957 Phone: (845) 559-3959 Phone: (360) 523-2227 License#: General Information: Fees: #of Gas Piping 1 Mechanical Permit Fees 55.40 #of Tankless Water Heaters 1 Total Calculated: 55.40 Deposits/Receipts: 0.00 Total Due: 55.40 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and e d this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISS PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6t" Street, Anacortes WA 98821 !` Phone: (360) 293-1901 PLUMBING & MECHANICAL PERMIT APPLICATION Please complete all applicable information and submit to buildingpermit@cityofanacortes.org PROPERTY INFORMATION PROJECT ADDRESS ASSESSORS PARCEL NUMBER 1-??NU 10tvl 5}-• P 5S l01 Lk PR JECT VALUATION COMMERCIAL PROPERTY OWNER OWNER PHONE 18U6- 559 -5q59 OWNER ADDRESS q$ZS OWNER EMAIL �r"�ve, la w n' �P�-� C- judcce rr1a�. APPLICANT INFORMATION PROPERTY OWNER ZCONTRACTOR OTHER: NAME PHONE CPI Plumbing, Heating, Cooling 360-218-7863 ADDRESS EMAIL 1900 Railroad Ave, Mt. Vernon, WA 98273 permitting@cpiplumbing.com CONTRACTOR INFORMATION NAME PHONE CPI Plumbing, Heating, Cooling 360-428-5636 CONTRACTOR'S BUSINESS LICENSES* STATE LICENSE# EXPIRATION *All Contractors & Subcontractors must have a valid CPIPLPG780MI 2023 City of Anacortes business license prior to doing work UBI LICENSE# EXPIRATION in the City. 604-909-749 2023 ADDRESS(STREET,CITY,STATE,ZIP) EMAIL 1900 Railroad Ave, Mt. Vernon, WA 98273 permitting@cpiplumbing.com PROJECT INFORMATION DESCRIPTION OF PROPOSED WORK: IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? u YES a NO If YES,provide the permit/application number: Plumbing/Mechanical Permit Application Updated December 2021 Page 1 of 3 MECHANICAL APPLIANCE/EQUIPMENT INFORMATION(NEW AND RELOCATED) EQUIPMENTTYPE Indicate the number of fixtures for each equipment type TOTAL GAS ELECTRIC OTHER-Please specify COMMENT Furnace Wall Heater Water Heater Heat Pump Air Conditioner/Handler Radiant/Hydronic Heating Exhaust Fans Range Hood Fireplace Clothes Dryer&Duct Stove/Range/Oven Refrigeration Unit Gas Piping/Outlet(s) Boiler BTUs: Other TOTAL MECHANICAL OUTLETS I PLUMBING FIXTURES FIXTURE TYPE(NEW AND RELOCATED) TOTAL FIXTURE TYPE(NEW AND RELOCATED) TOTAL Toilets Refrigerator water supply Kitchen Sink Pressure Reduction Valve/Regulator Utility Sink Water Service Line Tub Water Piping Hand Sink Washing Machine Shower Electric Water Heater:Tank-less? Yes No❑ Dishwasher Backflow Prevention Device Urinal Hose Bib Floor Drain/Floor Sink Drinking Fountain Hydronic Heat in:❑Floor ❑Wall Grease Interceptor Other-please specify: TOTAL PLUMBING FIXTURES Plumbing/Mechanical Permit Application Updated December 2021 Page 2 of 3 PLUMBING & MECHANICAL PERMIT APPLICATION CHECKLIST COMMERCIAL RESIDENTIAL 0M_ SUBMITTAL REQUIREMENTS c D 3 0 Z _ W_ m n Z n Z y D 6) D m r Plumbing&Mechanical Permit Application ✓ ✓ ✓4 Mechanical Plans ✓ Structural Calculations State Non-Residential Energy Code Compliance Form ✓ Manufacturer's Specifications/Cut Sheets ✓ ✓ ✓ Plumbing Plans ✓ Listed&Tested Fire Stopping Assemblies Elevation View for Roof Mounted Equipment ✓ ✓ Existing Floor Plan ✓ ✓ New Floor Plan ✓ ✓ ✓ NOTE: 1. Handouts and standard details may be found on the City's Planning, Community, & Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, & reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. If installing a backflow prevention device, it will need to pass test results of which will need to be submitted to the city for review. ACKNOWLEDGEMENTS & SIGNATURE By affixing my signature hereto,I certify that I am the owner,or am acting as the Owner's authorized agent, and that the application and documents contained with this submittal are complete and accurate to the best of my knowledge and abilities. SIGNATURE DATE Plumbing/Mechanical Permit Application Updated December 2021 Page 3 of 3 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater •Certified design according to ANSI Z21.10.3-CSA 4.3 latest standards for both indoor or outdoor installations(with optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to a length of 24 ft* (*see Installation Manual for additional information) •Compatible with 2"PVC vent up to 75 ft**and 150 it** ravren Gas Type using 3"PVC vent(**with no elbows) Recirclation/ Main/Sub Space Heating Flow Rate/Status •Designed for use in Residential and Commercial Temperature Setting applications(see below for available models and warranty terms) Combustion/Error •Gas Input Ranges NPE-180A2/S2-150,000 to 10,000 BTU/h Menu Button Up Button NPE-210A2/S2 -180,000 to 12,000 BTU/h Back Button Down Button NPE-240A2/S2 -199,900 to 13,300 BTU/h OK Button Power On/Off Button NPE-150S2 120,000 to 18,000 BTU/h •Hot Water Flow Rate Capacity(*based on 350F temperature rise) NPE-18OA2/S2 8.4 GPM NPE-21OA2/S2 10.1 GPM Sleek Design NPE-240A2/S2 11.2 GPM NPE-150 S2 6.8 GPM Compatible with Built-In Control Panel • TDR(Turn Down Ratio)up to15:1 2"PVC and 112"Gas Pipe •Dual Primary and Secondary Stainless Steel Heat with Diagnostics Exchangers for optimum efficiency and durability •Buit-In-Advanced Multi-Lines Control Panel with setup wizard allows adjustment of temperature settings and displays of Indoor and Outdoor operating status and error codes } 2"Intake Cap Venting Options •QOmOowfflOW-Technology-'A2"models come included with 2"Couplingt built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide r Pipemaximum comfort Outdoor Ven[Cap•INTELLIGENT Preheating-recognizes hot water usage patternsto intelligently provide hot water when needed(optional for"s"models)•Temperature Options -available temperature settings for Residential applications range from97°F up to 140*F with hightemperature Commercial mode capable of up to 185°F •Ready-Link Cascade Compatible for up to 32 units for increased Non-Direct Vent(Indoor) Non-Direct Vent(Outdoor) hot water production Common Vent Compatible-allows for cascade systems to use a Direct Veit(Indoor) single exhaust and/or intake pipe for up to 12 units with the use of the Common Vent Backflow Damper Collar Kit(n30014367A) _ oESlea •Compatible with Navffin(.Wi-Fi Control(nPBCM-AS-001) •Freeze Protection-maintains normal operation during freezing (D eFRrIFt�°® cENTIFIEo ambient temperatures down to-5°F(standard on all models) •Uniform Energy Factor Ratings for NG and LP units NPE-18OA2/21OA2/24OA2-0.95 UEF am NPE-180S2/21OS2/24OS2 -0.96 UEF NPE-150S2 -0.93 UEF *** •Compatible with Natural Gas(NG)and Propane(LPG) Job Name: (***requires installation of included Field Conversion Kit by a qualified gas servicer) •Approved for Installations on Manufactured Homes Location: •Optional NaviCirc Crossover Valve Compatible Engineer: •Certified by CSA,NSF 5,AHRI,AB1953 CA Low Lead,SCAQMD Wholesaler: (Rule 1146.2 Type 1-Complies with 14 ng/J or 20 ppm NOx @ 3%02) Contractor: •15-Year Heat Exchanger and 5-Year Parts Warranty(Residential)**** Model No.: 8-Year Heat Exchanger and 5-Year Parts Warranty(Commercial)**** (****see Navien Limited Warranty) Submitted to: •Optional accessories are available(see below) ®o 0 Q° CondensateNeutralaer Remote Controller Plumb 009323 -Lad (3/4") Ready-Link 3"VettTermilatan (GXXX001 322-Single Unit) OutdoorVent lGt External Pump Wire (30009323A-Lead Free) (GXXX001 324-Up to Units) CommumcationCable (30025801A) (GXXX001319) Caps and Wall Flanges (30022717B) (30025812A-for Pipe Cover) (GXXX001 325-Up to 16 Units) (GXXX000546) (GXXX3873B) 1-NPE2-SS-001-1.1 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater Specification Sheet Item NPE-150S2 NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 Heat Capacity Natural Gas, 18,000-120,000 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H (Input) Propane Gas BTU/H Uniform UEF(for NG&LP) 0.93 0.95 0.96 0.95 0.96 0.95 0.96 Energy Factor E 35°F(19°C) 6.8 GPM 8.4 GPM(32 Um) 10.1 GPM(38 Um) 11.2 GPM(42 Um) a Temp Rise (25.8 Um) Flow Rate 45 T(25°C) 5.3 GPM 6.5 GPM(25 Um) 7.8 GPM(30 Um) 8.7 GPM(33 Um) (DHW) Temp Rise (20 Um) 67T(36°Q 3AGPM 4.3GPM 4.4GPM 5.1GPM 5.3GPM 5.6GPM S.SGPM Temp Rise (13 Um) (16 Um) (17 Um) (19 Um) (20 Um) (21 Um) (22 Um) Dimensions 17.3 in(W)x 27A in(H)x 13.2 in(D) a Weight 62lbs 73lbs 168lbs 77lbs 73lbs 77lbs 73lbs (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) Installation Type Indoor or Outdoor Wall-Hung Overhead VleW Venting Type Forced Draft Direct Vent E Ignition Electronic Ignition 11�0emml 43.) a Water Pressure 15-150 PSI �_ Q s Natural Gas Supply Pressure �IJI (from source) 3.5 in WC-10.5 in WC m:� eamimmml T Propane Gas Supply Pressure 8 in WC-13in WC (from source) Natural Gas Manifold Pressure -0.04inWC (min-max) -0.40inWC -003inWC--0.55inWC -0.03 in WC--0.76 in WC -0.03 in WC--0.96 in WC Propane Gas Manifold Pressure -0.03inWC- _0.02 in WC--0.55 in WC -0.02 in WC--0.76 in WC -0.02inWC--0.96inWC NPE-180A2/210A2/240A2 (min-max) -0.40in WC SupplyConnections suppiyeonnections Minimum Flow Rate 0.5 GPM(1.9 Um),<0.01 GPM(0.04 Um)option for"A2"models* Description diameter 19 e © 40 Cold Water Inlet 3/4 in NPT A Airintake zin Connection Hot Water 3/,inNPT Sizes Outlet B Exhaust Gas Vent tin C Hot water Outlet 3/.m Gas Inlet 3/4inNPT D Gas Inlet '/.In W Main Supply 120VAC,60Hz E Recirculationlnlet =/.m " Power Supply Maximum F Condensate Outlet v,inPower 200 W(max 2 A),350 W(max 4 A)with external pump connected Consumption G Cold Water Inlet '/.in Casing Cold Rolled Carbon Steel ,3°homni Materials Heat Primary Heat Exchanger:Stainless Steel NPE-15092/180S2/210S2/240S2 Exchangers Secondary Heat Exchanger:Stainless Steel Exhaust 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel SupplyConnations SupplyConnections 2 in or 3 in Special GasVentType BH(Class II,A/B/C) Descr iodon diameter a Venting Intake 2 in or 3 in PVC,CPVC,Approved Polypropylene and stainless steel 2 in or 3 in Special GasVentType BH(Class II,A/B/C) A Air Intake tin �T Vent Clearances 0 in to combustibles B Exhaust Gas Vent tin C Hotwateroutlet V/in - ou r7p�gy® High Elevation 10,100 feet for both NG or LP gas.Please refer to Installation Manual for additional details and instructions. D Gas Inlet %in !LJ v,in 0 Flame Rod,APS,Ignition Operation Detector,WaterTemperature High Limit Switch,Exhaust Temperature High Limit Sensor,E Condensate Outlet Power Surge Fuse,Burner High Limit Fuse,Vent Installation Detector(VID) F Cold Waterinlet /.in - S ta° �smM -Available for"A2"models configured in an optional ComfonFlow recirculation mode.Energy consumption will increase when the system is configured for recirculation. Gas-fired,tankless,condensing,wall-mounted water heater(s)shall be direct vent NPE-2 Series models as manufactured by Navien,Inc.and are certified by CSA International to the latest edition ofANSI standard Z21.10.3/CSA 4.3.Water heater(s)shall have a 15(5)year limited Heat Exchanger warranty and 5(3)year limited Parts warranty(8(5)year Heat Exchanger and 5(3)year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is installed. (qty)NPE water heater(s)shall have a nominal flow rate capacity of GPM/GPH at-'F rise with rated input of BTU/hr.Water heater(s)shall be vented with 2"Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at a distance not to exceed 75'(or equivalent)with each elbow equal to 8'of pipe length or 3" Schedule 40/80 PVC/CPVC,approved polypropylene and stainless steel vent pipe at a distance of 150'(or equivalent)with each elbow equal to 5'of pipe length.Water heater(s)is rated for 150 PSI working water pressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WC for natural gas and 8.0"to 13.0"WCfor propane.Unit(s)shall have a steel case,dual stainless steel heat exchangers,eco premixed burner,negative pressure gas valve,dual venturi,3/4"inlet gas connection,3/4"brass inlet/outlet water connections,water holding capacity of 0.6 gallon for the NPE-150S2,1.0 gallon for the NPE-180A2 model(0.7gallonsfor NPE-180S2 model),1.2 gallons for the NPE-21OA2/NPE-24OA2 models(0.7 and 0.9 gallons for NPE-21OS2 and NPE-240S2 models respectively),and a condensate collector.The NPE-180A2 model weighs 73 lbs(NPE-I80S2 weighs 68lbs),and the NPE-21OA2/NPE-24OA2 models weigh 771bs(NPE- 210S2 and NPE-240S2 weigh 731bs)and The NPE-150S2 weigh 62lbs.Unit(s)shall include features such as an adjustment for installations at high elevation,temperature lockout,and temperature options from 97-120°Fin 1°F intervals and 120-140°F in 1°F intervals.The unit(s)shall include additional temperature options of 140-185°F in 1°Fintervals,for high temperature commercial applications.All NPE"A2"models shall include an internal circulation pump and 0.5-gallon buffer tank.The water heater(s)shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors,sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal combustion efficiency.Unit(s)shall include safety featuressuch as flame sensor system,high limitsensors,overheat prevention device,freeze protection mode,and fan motor rotation detector.Multi-system(cascade)applications that require 2 to 32 units shall be installed by connecting the units using cable only connections(Ready Link).The water heater(s)exceeds the energy efficiency requirements of ASHRAE 90.1-2010 and is listed by SCAQMD rule 1146.2(Type 1)for Low NOx that complies with 14 ng/)or 20 ppm NOx requirements @ 3%02. *Navien reserves the right to change specifications at any time without prior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.Navienlnc.com 1-NPE2-SS-001-1.1