HomeMy WebLinkAboutPermit File BLD-2022-0944 3010 Georgia Place T f3 City of Anacortes Invoice/Permit#: BLD-2022-0944 G 904 6th Street Applied date: 12/14/2022 "0 RO.Box 547 Issue date: 12/28/2022 t Anacortes, WA 98221-0547 Expire date: 06/25/2024 (360) 293-1901 Job Address: 3010 GEORGIA PL Permit Type: Fire Sprinkler Permit ANACORTES WA 98221 Project: APN: P108595 Remarks: Install a NFPA 13D multipurpose fire sprinkler system in a new SFR. Owner: BONNIE VANSICKLE Contractor: X-FIRE SECURITY Address: 3708 35TH AVE SW Address: 1511 KENTUCKY ST SEATTLE WA 98126 BELLINGHAM WA 98229-4718 Phone: (206)249-3182 Phone: (360) 715-8088 License#: General Information: Fees: Building Valuation 12521 Building Permit Fee 223.25 Plan Review Fee 145.11 State Building Code Fee Comm 25.00 Total Calculated: 393.36 Deposits/Receipts: 0.00 Total Due: 393.36 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation,guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and mine this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISS woo•uopom;suooaaplaj)l@8aj6:lIVW3 ° ° 0 133HS M3AOO Nro AS NMVJO A=.j31VOS ZZ/0£/LL31VO SV69-96L(09C)xej W W 99SS-LOL-09£:3NOHd ••� .M •°�� 990B-SLt(09E) x O LZZ96 VM'S'aINOOVNV -�=IHIVOS m NOISIA98 LZZ96 W31SAS HTDININdS Mild 6zz96 NOLL0f12115NOD 2i3013aN 6IOZ Q£ IsG OIJIGa[tddlQ 31VO tlM'S31tlOOtlNV 3SOdandu-1nw -IS AM n ua)4 LqL d Id VI'J;iO3J OLOE ;S tilon;ua�{LLSL 'NOlOVNiNOO :3di.LWNISAS NOISIA32i ;SS321OOV 31lS (If 1VdJN 3ON3aIS3N 31NOISNVA 086£-1 *� E. o w w W O O Ise S8 w a ? w a W w „€a €a r` g a _a� p w Aa � azw ❑ w L A3 sea 3 Q w - z wLLw " .�� c ❑-. a s _ a o o m a 3 z_ p � ._•� J _ ❑ i w w o _S4; " r g 33gg y,'f a Jlimrcx .''-E� d D a iy 1 ;! A31 w® b E a)a w ,/fir w m Rt w 5 w g a '❑ xw ac >w C ('� z Uo d , w a s V o w Z E _ c� wrca �. v 5 W F z < c k LsA xz z zoF Q LIJ a p wa -<.> S P;LL - /� < uS vw uF� = - w =ate 1' p YLL S rn� 6S� ai3^ . . ~en M iw �zRa � an � o a Q Hp '�~� a b N r�'f N N'R ...� /•• RII 2 aj :.`.. 1 a $Y G' UJ r� �'G9 •�)••S x� w w lip t7 .:. GC .�3 iw �� = a _ fad x w o•:. 121:2, o rcd a -rl° k� � oN oCZ 8 � a zLJIla i�oO r�H V wrcLL� mi o : a»6 ^e ` wK JJW OQ 6 :1T u�2Zi ;Ali .. ... 2 Op c 'U d B `'3iAa � w iw xw+ma v. x J W W ❑ a W ❑ i I ❑ 0 o W f �.I �I � II i G � I ,I �'III'� a•a j i' ' 1 sf 3� N m m � x G I O w O I� �F�FL' O li Z ; '!!-'��.''!�"; 1 t Z W l W I.7 W III' a E W � W '' G _ _� �. _ z r I' r r r o w e. w 1 w W w L yw3== o � J 1 I I'`KktL . �w 1 � as : k as^ € �a I I� 19 H. ab''B a n o ae L^E•" a5gs� =g a li �a= w Z �� .Jim=Swy I a. -3 »€x�r a wag I L�_ .I i. €sam>g3g€ooY€sz=€3n.. I ZO ®® a a v� x �.€� �a e a s w rr § sd g 1 a �a~ W� z°� ogf b € Z z 2 sa jai e g88 I. .I •A�•i O Q O Z _ �I DAve = DAve 0 II �t T cave EE 3x a WIRD �2 cm �° 7 a e3 IMP. g a i R uj ` rn� v, rnE �, V #aI: � a 'o �LL � ay O a 'i O 6 I W U 1 0 ; a ,,,t LU a N'6' j I Z Z W IIEI E 4o wG ., $g3� 1 ova W a m b €'S3e `) _. 93 E W g I va a� r o. w "s� e�',escewj 3 + �. a� Via= �e = u O L3O , li w U W ��CII7O�7 g�� wa > " u>I ❑$ s € o� a _j Of3 E 3 LU a as h a�a3 a5 € ` � Z o X of $w3 Z S 6 `� �.W n m a "CII� i g� a 0 a � e � � 3 a ❑4 y �a� y W - Wvl� V '1 u I �t aEzm �E � � mo Q :� f~q V,V y� V\ V W o u y O"Z.. S N <az ?Yv ry a7 woo•uol;oru;suoojaplau„@BajB:llyw3 0 NOOld N3mo-1 I OlN Ae wvNO ,L=„,,31VOS ZZIUM 31VO 9469-99L(0 9£)xej W l" G>vWa W 8899-LOt09£:3NOHd ,n ...m.m„m 8808-SLtl09£) U 2 LZZ96 tlM`S31NOOVNV �LwJ31VOS NOISIA3N LZZS6 W31SAS Z131)iN12ldS MIA 6ZZ86 ,z p.0 133111S NZZ OLOL KOIIIQ3 d VM`S3INO3VNtl 3SOd21ndllinW .'vm.wey6ulllae m • w NOLLonN1SNOO N3013NH 6IOZ Q£L V&im 31tl0 Id VIEJNO3�J OLO£ iS tiln;ua)i LLSL :NOlOVN1NO3 :adALW31SAS NOISIA3N :SS3N3OV3IIS a£6 tJd:jN 30N3alS3U 31MOISNVA 086£-1 )III s X)4!IPjV aauo4s < J o ................. 1 a I I ve. , • 1 I I i s // 914- cc m / I 1 1 I :^r 1 I rmr i 11 l z Z I I I \ 11 \7oCL o o. ilI I I Q' r m 1 p LL � m 11 t �_ um wa �6 I m W 0 / . h 1 'c _ KS - Z i L w f 1 }o � Hy s - ---—-—-—-—-—-—-—-—-—-— I v ---- =u ff s o s I , M1 J� -—-—- -—-—-—-—- I _ II 1 I I . F a \LPIA I n — 1 I 1 ` J I 3 _....._.... Z G L adols 1 ( c = I v5+ I -1 ;I II .,:III woo•uogoruysuoajaplaj)f@BaJB:•llvw3 O NOON NIVW 1 0111 AS NMVNO I L NIVOS ZZIO£IW31tl0 91,69-99L109E)xej � W W 98SS-LOL-09£ 3NOHd 8908-S LL-l09£) z O LZZ86 VM IS31NODVNV -L',VIVOS,U NOISIA3N LZZ96 W31SAS H31HNRIdS 3ZIId 6ZZ?6 o m q lz- 133N1S NZZ OLOL NOLLIQ3 t VM'S31NO3VNtl •tlM'wey6uglag w w W Oi p NOI onId1SNOD N30l3NN 6IOZ Q£I tld:OAI 31tl0 1d VION030 OLOE 3SOdtindllmw .,S,c)hr„uaN I•SI• S>a M M '.NOlOVN1NOO 3dA,LIA3•LS[S NOISIA316 SS3NOOV3119 OUWAN 30N3alS3N 31>101SNVA 086£-1 DIID!Suen aluuof r '-DONEIQIS3 �j 3-I�40ISNVA _ Q Z s4aalTyly aauOls a .......... �Ce. lr : m \ r.n' \ M z r i r z@V) ci e b ;q. keUP z � 1 - - N m m a� w m j I w \ aoelda�yuew '' pd 1 _ice - -i' Z i � J '1 �M � 5• r I i v �-, a T z - l e 3 O LL J 1 ,c z� cL U m m ¢) 3- 'Xt oAo c �—III I _ - n, I m 1 z" 3 a 1 I U m\\ + \ ✓III i I --!` l . L 1 Z III : I c 3. 3 -- —_—_ 1� -I--— — ------- —gam , d c c 9.z p a a '�1 (sY6)ooL e6uer - @ '; I o - -—-—-—-—-—-—-—-- L...-.�f-. _ �,I a 6- pj LL1y c 1- i Al o - -- - --�- 1- - (�� I I = I C �e ---- -- - PLANNING,COMMUNITY,& ECONOMIC DEVELOPMENT DEPARTMENT FIRE SPRINKLER PERMIT APPLICATION j Mailing Address:P.O. Box 547,Anacortes, WA 98221 `agCOR� Office Location: 904 6`r'Street, Anacortes YEA 98821 Phone: (360)293-1901 PLE4SE REFER TO THE FIRE SPRINKLE PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS ❑ MODIFY EXISTING SYSTEM INSTALL NEW SYSTEM ❑ UNDERGROUND FIRE LINE PROJECT ADDRESS(Street,Suite#): PARCEL(S)#: P108595 3010 Georgia Anacortes,WA 98221 PROJECT VALUATION: $12,621.50 APPLICANT: X-Fire Security Phone: 360-715-8088 Address(Street.City.State,Zip): Email Address: projects@x-fire.us 1511 Kentucky Street,Bellingham WA 98229 PROPERTY OWNER: Bonnie VanSickle Phone: Address(Street,City,State,Zip): 3708 35th Ave SW Email Address: Seattle,WA 98126 CONTACT PERSON: Dan Eardley Phone: 360-715-8088 Address(Street,City,State,Zip): Email Address: dan@x-fire.us 1511 Kentucky Street,Bellingham WA 98229 CONTRACTOR:* X-Fire Security Phone: 360-715-8088 Address(Street,City,State,Zip): Email Address 1511 Kentucky Street,Bellingham WA 98229 projects@x-fire.us *All Contractors&subcontractors must have a valid City of State Sprinkler Certificate&License#: Exp.Date: Anacortes business license prior to doing work in the Cin. XFIRE"961 PN 12131122 Contact the Citr's Finance Department at(360)299-1968. Business License#:602167180 Exp.Date: 12/31/22 COMMERCIAL ❑ RESIDENTIAL OCCUPANCY CLASS: SPRINKLER STANDARD: HAZARD CLASS: Is this work,associated with another project'? Yes❑ No If yes,specify: PROPOSED WORK: NFPA 13D Multipurpose Fire Sprinkler System.Installation in a New Residential Home I declare under penalty of perjury that the information I have provided on this form/application is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to ty City of Ana es. Print Name:( &P,54I t ONiner ❑ Agent ispecify): I lug Signature: Date: Fire Sprinkler System Calculations X-Fire Security 1511 Kentucky Street,Bellingham WA Job No: L-3980 Job Name: VanSickle Residence Building Type: Single Family Residence Location: 3010 Georgia PL,Anacortes WA System Type: NFPA 13D 2019 WAMma�■■■■■■■■■■■■■TON STATE■■■■■■■■ ■ i Ala M1oTtCT10N SPIONKM� � •'.' ■ Charlie Johnathar+FUmer as i 4425-0422-A UW911 XF 1PN i ■ ■ 1■nt � Designed by X-Fire Security- 1511 Kentucky Street,Bellingham WA- 360-715-8088 L-3980 VanSickle Residence-Two Head Calculation- (H.24 H.31) Page 2 of 9 Final Calculations-Summary Wednesday, November 30, 2022 Hydraulic Design Information Sheet Job Name VanSickle Residence Opened Date 11/30/2022 Location 3010 Georgia PL,Anacortes WA Job No L-3980 Building Type Single Family Residence Ceiling Height (ft) 9 Calculated By Charlie Rimer Construction Combustible Occupancy Residential System Design Type of Calculation NFPA 13D 2019 Listed Flow at Start Point(gpm) 13.000 System Type Wet Listed Pressure at Start Point(ps 9.100 Sprinkler Make Reliable Maximum Listed Spacing (ft) 16 Sprinkler Model RFC43 Domestic Flow(gpm) 0.000 Sprinkler Size (in) 0.50 Elevation at Highest Outlet (ft) 224 Sprinkler K-Factor 4.3 Temp. Rating (°F) 165 Coverage Area(ft2) 256 Listed Flow(gpm) 13.000 Calculation Summary Flowing Sprinkler Heads H.24 H.31 Flow Required (gpm) 26.000 Pressure Required (psi) 26.293 At Reference Point METER Overhead C-Factor Used 150 Underground C-Factor Used 150 Water Supply Water Flow Test: Static Pressur 60.000 Residual Pres 52.500 Flow(gpm) 35.000 Elevation (ft) 215 Manifold &Water Flow Switch Additional Pressure Loss (psi) 4.60 L-3980 VanSickle Residence-Two Head Calculation- (H.24 H.31) Page 3 of 9 Final Calculations-Water Supply Curve Wednesday, November 30, 2022 100 90 80 70 60 50 ■ ■ ■ 40 • ■ ■ ■ 30 20 N 10 en N N a` 0 5 10 15 20 25 30 35 40 45 Flow(N 1.85)(gpm) 00 Demand Curve Required Pressure: 26.293 psi @ 26.000 gpm Required Flow: 26.000 gpm O-----e Supply Curve Static Pressure: 60.000 psi @ 0.000 gpm Residual Pressure: 52.500 psi @ 35.000 gpm Available Flow: 35.000 gpm >4■ ■ ■■0 Pressure Cushion Available Pressure: 55.673 psi @ 26.000 gpm Pressure Cushion: 29.380 psi L-3980 VanSickle Residence-Two Head Calculation- (H.24 H.31) Page 4 of 9 Final Calculations-Nodes Wednesday November 30 2022 Actual Actual Elev. Press. Flow Node No. R (psi) (gpm) Model-Coverage(DxW)-Temperature S.0 205.0 24.547 0.000 SOURCE HA 213.0 20.803 0.000 RFC43-1616-165 D.T.1 224.0 13.129 0.000 Rehau PEX 1.00in Dom Tee R.1.A 213.0 20.751 0.000 T.1 213.0 20.763 0.000 CPVC 1.598x1.598x0.875in Tee LA 213.0 21.033 0.000 CPVC 1.50in 90 Ell H.2 213.0 20.936 0.000 RFC43-1616-165 D.T.2 224.0 13.614 0.000 Rehau PEX 1.00in Dom Tee R.2.A 224.0 15.902 0.000 L.2 213.0 20.786 0.000 CPVC 1.50in 90 Ell T.2 213.0 19.311 0.000 Rehau PEX 0.875x0.875x0.875in Tee H.3 213.0 20.457 0.000 RFC43-1212-165 D.T.3 213.0 19.594 0.000 Rehau PEX 1.00in Dom Tee L.3 224.0 15.895 0.000 CPVC 1.50in 90 Ell T.3 224.0 15.828 0.000 CPVC 0.875x0.875x1.598in Tee R.3.13 213.0 19.101 0.000 HA 213.0 20.575 0.000 RFC43-1818-165 T.4 224.0 14.989 0.000 Rehau PEX 0.8750.8750.875in Tee D.T.4 213.0 20.412 0.000 Rehau PEX 1.00in Dom Tee RA B 224.0 13.754 0.000 H.5 213.0 20.567 0.000 RFC43-1616-165 T.5 224.0 14.887 0.000 Rehau PEX 0.8750.8750.875in Tee H.6 213.0 20.979 0.000 F1 R44A6-1212-155 T.6 224.0 12.983 0.000 Rehau PEX 0.875x0.875x0.875in Tee H.7 213.0 20.285 0.000 RFC43-2020-165 H.8 213.0 19.978 0.000 RFC43-1616-165 H.9 213.0 19.634 0.000 RFC43-1616-165 H.10 213.0 19.466 0.000 RFC43-1616-165 H.11 213.0 19.371 0.000 RFC43-1212-165 H.12 213.0 20.059 0.000 RFC43-1616-165 H.13 213.0 20.336 0.000 RFC43-1616-165 H.14 213.0 19.900 0.000 RFC43-1616-165 H.15 213.0 19.580 0.000 RFC43-1616-165 H.16 213.0 19.725 0.000 RFC43-1616-165 H.17 224.0 15.677 0.000 RFC43-1616-165 H.18 224.0 15.450 0.000 RFC43-1212-165 H.19 224.0 15.057 0.000 RFC43-1616-165 H.20 224.0 15.321 0.000 RFC43-1616-165 H.21 224.0 14.701 0.000 RFC43-1616-165 H.22 224.0 11.435 0.000 RFC43-1616-165 H.23 224.0 14.303 0.000 RFC43-1616-165 H.24 224.0 9.133 13.000 RFC43-1616-165 H.25 224.0 12.105 0.000 RFC43-1616-165 H.26 224.0 13.572 0.000 RFC43-1818-165 H.27 224.0 13.350 0.000 RFC43-1616-165 H.28 224.0 13.947 0.000 RFC43-2020-165 H.29 224.0 12.808 0.000 RFC43-1616-165 L-3980 VanSickle Residence-Two Head Calculation - (H.24 H.31) Page 5 of 9 Final Calculations -Nodes Wednesday, November 30, 2022 Actual Actual Elev. Press. Flow Node No. (ft) (psi) (gpm) Model-Coverage(DxW)-Temperature H.30 224.0 14.934 0.000 RFC43-2020-165 H.31 224.0 9.100 13.000 RFC43-1616-165 FT.31 224.0 10.133 0.000 Rehau PEX 1.00in Sprinkler Tee FT.24 224.0 10.166 0.000 Rehau PEX 1.00in Sprinkler Tee L-3980 VanSickle Residence-Two Head Calculation - (H.24 H.31) Page 6 of 9 Final Calculations-Pipes Wednesday, November 30, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p2 T.4 -13.603 0.875 0.806 14.887 to 150 2R 1.400 0.000 Vel=4.7 T.5 8.894 0.0465 0.00 2.206 0.103 sup0 METE 0.000 1.610 85.000 24.547 to 150 MNF 0.000 -4.331 Vel =4.1 S.0 26.000 0.0174 4.60 85.000 1.477 p4 T.4 -20.143 0.875 12.765 14.934 to 150 1 H 1 R 1.200 0.000 Vel = 1.3 H.30 2.355 0.0040 0.00 13.965 0.056 p3 H.30 0.000 0.875 10.622 14.887 to 150 1 H1 R 1.200 0.000 Vel = 1.3 T.5 2.355 0.0040 0.00 11.822 0.047 p15 FT.24 11.249 0.875 15.345 12.105 to 150 1 H 1 R 1.000 0.000 Vel =-7.9 H.25 -14.751 0.1186 0.00 16.345 1.939 p16 H.25 0.000 0.875 6.207 12.983 to 150 1 R1 H 1.200 0.000 Vel =-7.9 T.6 -14.751 0.1186 0.00 7.407 0.879 p37 T.3 -27.709 0.875 7.530 15.677 to 150 1 R1 H 1.200 0.000 Vel =2.8 H.17 5.212 0.0173 0.00 8.730 0.151 p9 H.17 0.000 0.875 12.103 15.450 to 150 2H 1.000 0.000 Vel =2.8 H.18 5.212 0.0173 0.00 13.103 0.227 p8 H.18 0.000 0.875 6.434 15.321 to 150 2H 1.000 0.000 Vel =2.8 H.20 5.212 0.0173 0.00 7.434 0.129 p6 H.20 0.000 0.875 14.277 15.057 to 150 2H 1.000 0.000 Vel =2.8 H.19 5.212 0.0173 0.00 15.277 0.264 p7 H.19 0.000 0.875 19.573 14.701 to 150 2H 1.000 0.000 Vel =2.8 H.21 5.212 0.0173 0.00 20.573 0.356 p14 H.21 0.000 0.875 21.946 14.303 to 150 2H 1.000 0.000 Vel =2.8 H.23 5.212 0.0173 0.00 22.946 0.397 p13 H.23 0.000 0.875 19.597 13.947 to 150 2H 1.000 0.000 Vel =2.8 H.28 5.212 0.0173 0.00 20.597 0.357 p19 H.28 0.000 0.875 18.040 13.614 to 150 1 R1 H 1.200 0.000 Vel =2.8 D.T.2 5.212 0.0173 0.00 19.240 0.333 p18 D.T.2 0.000 0.875 1.226 13.572 to 150 1 H 1 R 1.200 0.000 Vel =2.8 H.26 5.212 0.0173 0.00 2.426 0.042 p20 H.26 0.000 0.875 11.807 13.350 to 150 2H 1.000 0.000 Vel =2.8 H.27 5.212 0.0173 0.00 12.807 0.222 L-3980 VanSickle Residence-Two Head Calculation- (H.24 H.31) Page 7 of 9 Final Calculations-Pipes Wednesday, November 30, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p17 H.27 0.000 0.875 11.564 13.129 to 150 1 R1 H 1.200 0.000 Vel =2.8 D.T.1 5.212 0.0173 0.00 12.764 0.221 p47 D.T.1 0.000 0.875 7.032 12.983 to 150 2R 1.400 0.000 Vel =2.8 T.6 5.212 0.0173 0.00 8.432 0.146 p51 T.2 -14.991 0.875 6.008 19.466 to 150 1 B1 H 8.000 0.000 Vel =-2.2 H.10 -4.088 0.0110 0.00 14.008 0.155 p22 H.10 0.000 0.875 9.284 19.580 to 150 2H 1.000 0.000 Vel =-2.2 H.15 -4.088 0.0110 0.00 10.284 0.114 p21 H.15 0.000 0.875 12.190 19.725 to 150 2H 1.000 0.000 Vel =-2.2 H.16 -4.088 0.0110 0.00 13.190 0.146 p25 H.16 0.000 0.875 14.817 19.900 to 150 2H 1.000 0.000 Vel =-2.2 H.14 -4.088 0.0110 0.00 15.817 0.175 p27 H.14 0.000 0.875 13.399 20.059 to 150 2H 1.000 0.000 Vel=-2.2 H.12 -4.088 0.0110 0.00 14.399 0.159 p26 H.12 0.000 0.875 19.471 20.285 to 150 2H 1.000 0.000 Vel =-2.2 H.7 -4.088 0.0110 0.00 20.471 0.226 p30 H.7 0.000 0.875 10.329 20.412 to 150 1 H1 R 1.200 0.000 Vel=-2.2 D.T.4 -4.088 0.0110 0.00 11.529 0.127 p29 D.T.4 0.000 0.875 2.814 20.457 to 150 1 R1 H 1.200 0.000 Vel =-2.2 H.3 -4.088 0.0110 0.00 4.014 0.044 p28 H.3 0.000 0.875 9.729 20.575 to 150 2H 1.000 0.000 Vel =-2.2 HA -4.088 0.0110 0.00 10.729 0.118 p46 HA 0.000 0.875 9.050 20.763 to 150 1 B 1 H 8.000 0.000 Vel =-2.2 T.1 -4.088 0.0110 0.00 17.050 0.188 p43 S.0 -20.549 0.875 4.990 20.979 to 150 1 H 0.500 3.465 Vel =2.9 H.6 5.451 0.0188 0.00 5.490 0.103 p34 H.6 0.000 0.875 20.937 20.567 to 150 2H 1.000 0.000 Vel =2.9 H.5 5.451 0.0188 0.00 21.937 0.413 p32 H.5 0.000 0.875 11.279 20.336 to 150 2H 1.000 0.000 Vel =2.9 H.13 5.451 0.0188 0.00 12.279 0.231 p31 H.13 0.000 0.875 18.013 19.978 to 150 2H 1.000 0.000 Vel =2.9 H.8 5.451 0.0188 0.00 19.013 0.358 L-3980 VanSickle Residence-Two Head Calculation- (H.24 H.31) Page 8 of 9 Final Calculations-Pipes Wednesday November 30, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p33 H.8 0.000 0.875 17.294 19.634 to 150 2H 1.000 0.000 Vel =2.9 H.9 5.451 0.0188 0.00 18.294 0.344 p23 H.9 0.000 0.875 0.905 19.594 to 150 1 H 1 R 1.200 0.000 Vel =2.9 D.T.3 5.451 0.0188 0.00 2.105 0.040 p24 D.T.3 0.000 0.875 10.671 19.371 to 150 1 R1 H 1.200 0.000 Vel =2.9 H.11 5.451 0.0188 0.00 11.871 0.223 p50 H.11 0.000 0.875 1.985 19.311 to 150 1 R1 H 1.200 0.000 Vel =2.9 T.2 5.451 0.0188 0.00 3.185 0.060 p39 T.1 -24.636 1.598 0.896 20.751 to 150 1 R 0.700 0.000 Vel =2.6 R.1.A 16.461 0.0077 0.00 1.596 0.012 i0 R.1.A 0.000 1.598 11.000 15.902 to 150 0.000 4.764 Vel =2.6 R.2.A 16.461 0.0077 0.00 11.000 0.085 p35 R.2.A 0.000 1.598 0.912 15.895 to 150 1 L 0.000 0.000 Vel =2.6 L.3 16.461 0.0077 0.00 0.912 0.007 p36 L.3 0.000 1.598 1.164 15.828 to 150 1 B1 L 7.500 0.000 Vel =2.6 T.3 16.461 0.0077 0.00 8.664 0.067 p38 TA -11.249 0.875 3.474 15.828 to 150 1 B1 R 8.200 0.000 Vel =-6.0 T.3 -11.249 0.0718 0.00 11.674 0.839 p48 T.6 -19.964 0.875 7.062 13.754 to 150 1 B 7.500 0.000 Vel =-5.1 R.4.B -9.539 0.0530 0.00 14.562 0.771 i1 R.4.B 0.000 0.875 11.000 19.101 to 150 0.000 4.764 Vel =-5.1 R.3.B -9.539 0.0530 0.00 11.000 0.582 p49 R.3.B 0.000 0.875 3.271 19.311 to 150 1 R 0.700 0.000 Vel =-5.1 T.2 -9.539 0.0530 0.00 3.971 0.210 p40 T.1 -20.549 1.598 1.236 20.786 to 150 1 R1 L 0.700 0.000 Vel =-3.3 L.2 -20.549 0.0117 0.00 1.936 0.023 p41 L.2 0.000 1.598 0.992 20.803 to 150 1 H 1 L 0.500 0.000 Vel =-3.3 H.1 -20.549 0.0117 0.00 1.492 0.017 p42 H.1 0.000 1.598 10.343 20.936 to 150 2H 1.000 0.000 Vel =-3.3 H.2 -20.549 0.0117 0.00 11.343 0.132 p45 H.2 0.000 1.598 4.349 21.033 to 150 1 L1 H 4.000 0.000 Vel =-3.3 L.1 -20.549 0.0117 0.00 8.349 0.097 L-3980 VanSickle Residence-Two Head Calculation- (H.24 H.31) Page 9 of 9 Final Calculations-Pipes Wednesday, November 30, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p44 L.1 0.000 1.598 0.770 24.547 to 150 1 L 3.500 3.465 Vel =-3.3 S.0 -20.549 0.0117 0.00 4.270 0.050 p12 FT.31 1.751 0.875 13.484 10.166 to 150 2R 1.000 0.000 Vel =-0.9 FT.24 -1.751 0.0023 0.00 14.484 0.033 p5 T.5 -11.249 0.875 20.941 12.808 to 150 1 B1 H 8.000 0.000 Vel=6.0 H.29 11.249 0.0718 0.00 28.941 2.079 p10 H.29 0.000 0.875 18.111 11.435 to 150 2H 1.000 0.000 Vel =6.0 H.22 11.249 0.0718 0.00 19.111 1.373 p11 H.22 0.000 0.875 17.126 10.133 to 150 1 R1 H 1.000 0.000 Vel=6.0 FT.31 11.249 0.0718 0.00 18.126 1.302 hp31 H.31 0.000 0.875 0.000 10.133 to 150 1 H 1 B 11.000 0.000 Vel =6.9 FT.31 13.000 0.0939 0.00 11.000 0.000 hp24 H.24 0.000 0.875 0.000 10.166 to 150 1 H 1 B 11.000 0.000 Vel =6.9 FT.24 13.000 0.0939 0.00 11.000 0.000 i I Bulletin 006 Rev.K February 2017 Fellable Model RFC Series Residential Sprinklers cULus Listed Flat Cover Plate,Concealed Pendent Sprinkler i Product Features • cULus Listed as Residential Sprinklers - • Push-On cover plate installationf J • Low water flow requirements Product Description Model RFC30 Model RFC43 Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. LIN Model RFC30, RFC43, and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC49 Model RFC58 Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C)temperature rated fusible-link op- erating element.Sprinklers with a 165°F(74°C)temperature rating are ordinary temperature classification and should be used with a 135°F(57°C)temperature rated cover plate. Sprinklers with a 212°F(100°C)temperature rating are inter- mediate temperature classification and should be used with a 165°F(74°C)temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup,Model RFC30,RFC43,and RFC49 sprinklers allow 1/2" (13 mm)of cover plate adjustment.Model RFC58 sprinklers ft allow 3/4"(19 mm)of cover plate adjustment. Model RFC cover plates are available in a variety of finishes Solid Perforated as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or Model RFC Cover Plate perforated cover plates. Nominal K-Factor Max.Coverage Area Sprinkler Sprinkler Model gpm/psi'/2(1/min/bar'/2) ft x ft(m x m) Identification Number(SIN) RFC30 3.0(43.2) 14 x 14(4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20(6.1 x 6.1) RA0612 RFC49 4.9(70.6) 20 x 20(6.1 x 6.1) RA0616 RFC58 5.8(84) 20 x 20(6,1 x 6.1) RA0613 www.rellablesprinkler.com Model •-ntial Sprinkler SIN RA0612 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NPT or ISO 7-1 R1/2 Nominal K-Factor:4.3(62 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Rating Material Specifications 165"F(74"C)sprinkler Thermal Sensor:Nickel Alloy Solder Link 135"F(57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC Pins:Stainless Steel �+ c_ Deflector.Bronze Alloy Listings and Approvals Bottom View 91 Cup:Steel cULus Listed Model RFC43 Sprinkler Components and Dimensions 2-5/16"(58 mm) Threads Dia. Body Cup Tower 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link Nominal face of fitting to ceiling Deflector(retracted) ������� �3/16"(5mm) Pin(extended) ;i i I Deflector(extended) i Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0,63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5,5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 3 of 7 February 2017 www.reliablesprinkler.com Bulletin 135 April 2021 Rel IIII� Q Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Features Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2(non- cULus Listed Residential Sprinklers recessed)and Model W4 recessed concealed are required. • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element.A variety of K-Factors as well as recessed and conical concealed options are available as = - detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626.They are intended for installation in accordance with NFPA 13, 13R,and 13D. Application The Model F1 Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R,or NFPA 13D.The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy,where permitted by the design density shall be a minimum of 0.1 gpm/sf(4.1 mm/ NFPA 13, NFPA 13R,or NFPA 13D.For NFPA 13R and NFPA min),but in no case shall the flow and pressure be less than the 13D applications,the design flow and pressure shall not be minimum flow and pressure specified in the Listed Design Criteria less than the minimum flow and pressure specified in the Listed tables in this bulletin.Model F1 Res Series sprinklers are listed for Design Criteria tables in this Bulletin.For NFPA 13 applications, use in wet systems only. Residential Sprinkler Summary Sprinkler Sprinkler K-Factor Thread Size Max.Coverage Area ft Model Identification Orientation gpm/psi11Z NPT or ISO7-1 Installation Options x ft(m x m) Number(SIN) (Ipm/bar ) F1 Res30 R3511 Pendent 3.0(43) 112 Pendent or Recessed 16 x16(4.9 x 4.9) F1 Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res58 R3513 Pendent 5.8(84) 112 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed 14 x 14(4.3 x 4.3) F1 Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20(6.1 x 6.1) F1 Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed 20 x 20(6.1 x 6.1) F1 Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20 x 20(6.1 x 6.1) F1 Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 0) F1 Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1 Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) Note:Please note SIN difference between F1 Res58 HSW(R3533)and F1 Res58 HSWX(RA3533). www.reliablesprinkler.com HorizontalModel F1 Res44 SWC Conical Concealed . Technical Specifications Finishes Style:Conical Concealed Sidewall (See Table N) Threads:1/2"NPT or ISO 7-1 R1/2 Sensitivity Nominal K-Factor:4.4(63 metric) Fast-response Max.Working Pressure:175 psi(12 bar) Temperature Ratings 155°F(68°C) Material Specifications 175°F(79°C)('t Thermal Sensor:3 mm glass-bulb Cover Plates SWC Sprinkler Frame:Brass Alloy SWC Conical Concealed Plate(2) Button:Copper Alloy SWC-2(Slotted)Conical Concealed Plate(3) _ Sealing Assembly:Nickel Alloy with PTFE Sprinkler Wrenches Load Screw:Bronze Alloy Model W4 _ Deflector:Bronze Alloy SWC-2 Note: (1)Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (1)135°F SWC Conical Concealed Plate for 1557(68°C)sprinklers lit 135°F SWC-2(Slotted)Conical Concealed Plate for 175°F(79'C)sprinklers Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 11111102VUrVall 1"(25mm) 1"(25mm) +1-1/4"(6mm) +/_1/4"(6mm) Face of fitting to finished wall �2-7116"(62mm)` -� 2-5/8" 2-5/16' �_____� Top of Deflector Down 3 5/16" _�_ __=js from Ceiling to t Either (67mm)(58mm) -- ------ -- 84mm 4"to 6"(100mm to ( ) DIA. DIA. 150mm)or 6"to 12° DIA. 5/16' (150mm to 300mm) (Smm) Based on Hydraulic Calculations 1 5/8" (41 mm) Dimensions SWC&SWC-2 Concealed Cover Plate Installation Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria F1_-.1 ram Minimum Flow and Residual Pressure in Wet Pipe Systems(') Ordinary Temperature Rating Intermediate Temperature Rating Maximum Coverage Area(2) 155°F(68°C) 175°F(79°C) Deflector to Ceiling ft.x ft.(m x m) Flow Pressure Flow Pressure Distance gpm(I/min) psi(bar) gpm(1/min) psi(bar) 12 x 12(3.7 x 3.7) 13(49) 8.7(0.60) 14(53) 10.2(0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2(0.7) 14(53) 10.2(0.7) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) -- -- 4 to 6 inches 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) -- __ (100 to 150 mm) 16 x 18(5.5 x 5.5) 19(72) 18.7(1.31) -- -- 16 x 20(4.9 x 6.1) 23(87) 27.4(1.89) -- -- 12 x 12(3.7 x 3.7) 14(53) 10.2(0.7) -- -- 14x14(4.3x4.3) 15(57) 11.7(0.81) -- -- 15 x 15(4.6 x 4.6) 17(64) 15.0(1.03) -- 6 to 12 inches (150 to 300 mm) 16 x 16(4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16 x 18(4.9 x 5.5) 20(76) 20.7(1.43) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 Page 11 of 15 April 2021 Ref® www.reliablesprinkler.com REHHU:1 Unlimited PolymerSolutions DesignFIREPEXB RESIDENTIAL FIRE SPRINKLER SY:STEM and Installation f` AWN v - 2. DESIGN & APPLICATIONS 2.1 Applications 2.2 Types of Fire Sprinkler Systems The FIREPEX residential fire sprinkler system serves the requirements The NFPA 13D standard categorizes all fire sprinkler systems within for fire sprinkler systems as defined by National Fire Protection two general types:wet pipe systems and dry pipe systems. Association(NFPA)Standard 13D Installation of Sprinkler Systems in Wet pipe systems are filled with water and installed in areas not One-and Two-Family Dwellings and lb1anufactured Homes and the subject to freezing, Intemational Residential Code Section(IRC)P2904, -Dry pipe systems are not filled with water,and can be located in unheated areas subject to freezing, The purpose of NFPA 13D and IRC P2904 is to provide a sprinkler system that aids in the detection and control of residential fires,thus The FIREPEX system is for wet pipe systems only. offering improved protection against injury and loss of life,A sprinkler Within the wet pipe systems,NFPA 13D defines the layout of systems system that is designed and installed in accordance with this standard under the following types,for which the FIREPEX system can be is expected to prevent flashover(total involvement of the fire)in the installed: room of fire origin,where sprinklered,and to improve the chance for -Multipurpose Sprinkler System occupants to escape or be evacuated. -Passive Purge Sprinkler System -Stand-alone Sprinkler System RAUPEX white UV shield pipe and EVERLOC+fittings are approved for use in residential fire sprinkler systems as defined by NFPA 13D and IRC P2904 for a variety of residential applications including single- 2.2.1 Multipurpose Sprinkler Systems or two-family homes,town homes,modular homes and manufactured MUltipurpose systems are defined in NFPA 13D and IRC P2904 as a housing, piping system intended to serve both fire sprinklers and domestic plumbing needs.A multipurpose system integrates the piping — connected to a water supply with sprinklers that automatically discharge water over a fire area.All piping in a multipurpose system supplying sprinklers must be listed or conform to the piping specifica- tions in NFPA 130 or IRC P2904, To 0 .0,Hol Wabr F.SprinNer •----- ---i T/f Relief Valve Lbmeafic �om�snc �' Water Healer F e p t Fi.Wre Fire Spnnlder DamesUc FMure Fig.2.1:FIREPFXinsht((ation �ameeac Hat Walu Water Meter Ovmestic mob Water Se•nRe Line City Water Main Fig,2.2,Multipmyose system 4 3. SYSTEM OVERVIEW 3.1 Application The FIREPEX residential fire sprinkler system includes RAUPEX white UV shield(PEXa)pipe,EVERLOC+polymer and lead-free brass fittings,PEXa compression sleeves and EVERLOC+compression- sleeve tools, ' 1 The EVERLOC+compression-sleeve fitting system is a cold- expansion PEXa fitting system available in polymer and lead-free(LF) brass,assembled with a specially designed PEXa compression sleeve. The fittings are designed specifically for use with RAUPEX pipe and must only be assembled with EVERLOC+compression-sleeve tools. — - fig.3.3:EOFRLOC+c:omptession-sleeve tools 3.2 Standards and Certifications " - — RAUPEX white UV shield pipes are certified for use in residential fire sprinkler systems as defined by NFPA 13D or IRC P2904. ,. RAUPEX red and blue UV shield are not certified for fire sprinkler systems. The FIREPEX system is third-party certified by NSF International --- ---~` - (www.nsf.org)to the following standards: UL 1821 Standard for Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service Fig,3.1:RAUPEX awhile UV shield cosslini ed polyeth.lene(PFV,#pipe ASTM F877 Standard Specification for Crosslinked Polyethylene (PEX)Hot-and Cold-Water Distribution Systems GSA B137,5 Crosslinked Polyethylene(PEX)Tubing Systems for Pressure Applications NSF/ANSI 14 Plastic Piping System Components and Related Materials NSHANSI 61 Drinking Water System Components and Related .� Materials j NSF/ANSI 372 Drinking Water System Components—Lead Content t (complies with the lead-free requirements of the U.S.Safe Drinking Water Act) 3.3 Warranty RAUPEX UV shield pipe and EVERLOC+compression-sleeve fittings _-- and sleeves are backed by a 25-year limited warranty.EVERLOC+ Fig 3. EVERLOC+compression-sleeve fillings and PEaa compression sleeves compression-sleeve tools are backed by a 2-year limited warranty, REHAU offers this warranty when the installation is carried out in accordance with the requirements outlined in the REHAU PEXa IVananty 855.018.which is available as a separate document at www.na.rehau.comhAiarranties. 4. RAUPEX PEXa PIPE 4.1 Pipe Properties Speciticaticin English Sl Standard Crosslinked polyethylene is polyethylene(PE)which has undergone a Tensile 4194-4355 psi 26-30 N/mm change in molecular structure whereby the polymer chains are strength @68'F @ 20'c 18-20 chemically linked,crosslinked(X),with each other to form a three- 261 G�176'F 60�'1` psi @807 N/mm G dimensional network.The result is a flexible thermoset polymer with per ASTM D638 per ASTM D638 improved mechanical,thermal and chemical properties. 1700I111111ct No Break No Preak Resistance There are three methods of nlanUfaetUring PEX: Roughness e=0.00026 in, e=F.007 mm The peroxide method(PEXa),ASTM requires a minimum of 70% Temperature -40 to 200 F -40 to 2e C: crosslinking Working Range -The silane method(PEXb),ASTM requires a minimum of 65% Maximum 150 psig(m 210'F 1035 kPa M 99 c A"i V Short-term (48 hr) (43 11r) crosslinking Exposure The radiation method(PEXc),ASTM requires a minimum of 65% uv Resistance See T6218 AS I M��657 crosslinking RAUPEX pipe is manufactured using the peroxide method(PEXa), 4.2 Pipe Dimensions and Weights which yields the highest, most consistent level of crosslinking.PEXa RAUPEX white UV shield pipe for residential fire sprinkler systems is technology enhances flexibility and thermal memory,providing ease of available in nominal sizes ranging from 3/4 to 2 in.,and is in accor- handling and kink repair compared to PEXb and PEXc, dance to the dimensional standards defined in ASTM F376 and GSA 8137.5.RAUPEX is copper tube size(CTS)outside diameter(OD), PEXa has distinct advantages over other polymer and metal pipes: which means that the actual OD of the pipe is 1/8 in(3.18 mm)larger Resists pitting and stress corrosion than the nominal size. Resists scaling and deposit build-up when used vvith both hard and softened water Wall thickness is defined by the standard dimensional ratio(SOR). Minimizes noise that is transmitted through pipes RAUPEX UV shield pipe is SDR9,which equates to the outside Resists notching and abrasion damage diameter being approximately nine times the wall thickness,Since PEX pipe has a thicker avall than copper tube,the inside diameter(ID) RAUPEX is manufactured by REHAU in a facility whose quality is slightly smaller,However:since PEX pipe is not susceptible to the management system is ISO 9001 certified.In addition,RAUPEX erosion and corrosion issues of copper tube,systems can be designed production is independently monitored annually by NSF International, at higher velocities which allow for comparable sizing of a system. GSA Group and Underwriters Laboratories Inc.(UL). Table 4.2:RAUPEX White UV Shield Pipe Dimensions and Weights Table 4.1:RAUPEX Properties Average DD Min Wall Thickness Specification English sl d. r Minimum 58lb/(i' 926 kg/m- ASTM 1`876 3;'4 in 0.675(2222) 0.097(2.47) 0.10(0.151 Ue"site 1 In 1.125(28.58) 0.125(3.13) 0.17(0.26) Minimum 70% 70% ASTM H76 1 1/4 in 1.373(34.921 .153(3.881 0.25(0, ) C'egre:,of CrDSSli1116nq 1 1/2 in 1.625(41.28) 0.181(4.59) 0.35(0.52) Th T in 2.125 53.98 0,236'6 00) 0.60 O.0C1 \der, ermal 2.84 btu inl(ft�°F.hr) 0.41 W/(m`Kj DIN 16392 ConductiVit,' Coefficient of 9.33 x 10-4 inlft'F 0.14 mm/(m'C) Mean @ inear @68'F @90'c 20-70 C per DIN 4.3 Pipe Markings exparsion 1,33 x 10-3 in/ft`F 0.2 mm/(m'C) 16c 92 @212 F @1n0C RAUPEX pipe mai kh igs are repeated every 3 ft(0,9 m),list all certifications and approvals,and include an incremental footage odulus of 8',D00-13u,500 psi 600-900 Worm' Minimum @ marking to assist with installation. Hastieity C 68'f (4VO'C 2WC per DIN 43,500-58,000 psi 300-400 N/mm' 16892 @176'F 0180'C 5. EVERLOC+ COMPRESSION-SLEEVE FITTINGS 5.1 Fitting Scope 5.1.2 Fitting and Sleeve Markings The EVERLOC+compression-sleeve system is a cold-expansion PEXa All polymer fittings include the follnwOg marks for identification fitting system that is available in polymer and lead-free(LF)brass and is assembled with a specially designed PEXa compression sleeve.The R E H A U OR (`fitting is designed specifically for use with RAUPEX pipe and must `.404, only be assembled with the EVERLOC+compression-sleeve tools. EVERLOC+fittings for residential fire sprinkler applications are available in 3/4 to 2 in.sizes and are listed for use with RAUPEX white UV shield pipe(3/4 to 2 in.)manufactured in accordance with ASTM F876. - For a detailed description of the REHAU system components,refer to the REHAU Building Solutions Product Catalog(855.312), 5.1.1 Fitting Features Fig.5.2:Rtingk�emarking (e,g.,31) EVERLOC+polymer and lead-free(LF)brass fittings have the following features: 1, Four sealing edges 2. Pipe stop 3. Fitting collar 4, Tool jaw body Fig.5.3:Satch code(e.g.,production date) All LF brass fittings are marked"REHAU" W' Orr" i All sleeves include the following marks for identification REHHU Sleeve size(e.g.,3/4") Batch code for production date ® Fig.5A Sleeve markings Fig.5.1:EVERLOC+fitting features 11 5.1.3 Polymer Fittings EVERLOC+polymer fittings are available in couplings,tees,elbows, multi-port tees and plugs.All polymer fittings are produced from a polyphenylsulfone(PPSU)material,See also REHAU Technical Bulletin TB265 EVERLOC+Polymer Fitting Material-PPSU 5.1.4 Lead Free(LF)Brass Fittings EVERLOC+LF brass fittings are available as Couplings,tees,elbows, plugs and transition fittings to NPT thread and copper solder connections.All metal fittings are produced from ECO BRASS- (UNS Fig. .6:gIERLOC+PEXa compression s!aeves 69300 or CW 724R).See also REHAU Technical Bulletin T8264 EVERLOC+Load-free Brass Fitting Material. 5.1.6 Certifications The EVERLOC+compression-sleeve fitting system is certified to the following standards: UL 1821 Standard for Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service ASTM F877,Standard Specification for Crosslinked Polyethylene (PEX)Hot and Cold-Water Distribution Systems NSF/ANSI 14,Plastic Piping System Components and Related Materials NSF/ANSI 61,Drinking Water System Components—Health Effects NSF/ANSI 372,Drinking Water System Components—Lead Content GSA B137.5,Crosslinked polyethylene(PEX)Tubing Systems for Pressure Applications Fig 5.5:LElERLOC+polymer and LF brass fi ings 5.1.5 PEXa Compression Sleeves EVERLOC+compression sleeves are pmdrrced using a specially formulated PEXa material and are designed specifically for use with EVERLOC+fittings and RAUPEX pipe.EVFRLOC+compression sleeves have the following features: Co-extruded platinum-colored PE coating Squarely cut ends that can be slid over the pipe in either direction Grooved and roughened inside surface for locking the sleeve into place once slid over the pipe and fitting 12 7. INSTALLATION CONSIDERATIONS The following sequence is recommended to install the FIREPEX fire 7.2 Mounting FIREPEX Sprinkler Fittings J q g p g sprinkler system: Determine location of sprinklers based on design,Be sure to verify Determine fire sprinkler location that there are no obstructions or deviations from design.If modifica- Install sprinkler fittings tions are necessary,consult with the designer to ensure proper Route and connect pipe coverage of sprinklered area. Install plumbing fittings Install plumbing pipe The FIREPEX sprinkler fittings are available in 3/4 and 1 in.sizes. Install fire sprinklers Each fitting has a 112 in.NPT female adapter for mounting of the fire Perform pressure test sprinkler with integrated mounting holes for both horizontal and Perform flow test vertical installation.Fittings should be mounted using#10 x 1 112 in. wood screws, 7.1.Ensuring Design Meets Installation Guidelines FIREPEX sprinkler fittings are specially designed to affix the fire RAUPEX white UV shield pipe in 3/4 to 2 in.sizes is listed to supply sprinkler in place so that during activation,the reaction forces caused the FIREPEX system. by the flow of water through the sprinkler will not displace the sprinkler.FIREPEX sprinkler fittings may be mounted to a wood RAUPEX pipe in all sizes is listed for plumbing applications and can be blocking structure. connected to the sprinkler system as allowed by the local code. The following are guidelines for using RAUPEX white UV shield pipe and EVERLOC+compression-sleeve fittings in fire sprinkler systems: Protection must be provided for RAUPEX pipe and EVERL00+ fittings.The minimum protection must consist of either: One layer of 3/8 in.(9.5 mm)gypsum wallboard, A suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 Ibs per sq ft(1.7 kg per sq m)when installed with metallic support grids, - 1/2 in.(13 mm)plywood soffits, =- - One layer of 1/2 in.(13 mm)plywood,or Other material having a 15 minute fire rating. During remodeling or ceiling repair,use appropriate precautions to F9.71:Mounting FIREPEX spunkier fitting properly protect the pipe, -Do not use RAUPEX pipe or EVERLOC+fittings for sprinkler systems in combustible concealed spaces where sprinklers are required. 7.2.1 Determining Mounting Height RAUPEX pipe and EVERLOC+fittings are intended for use in areas The following guidelines may be used to correctly position the where the maximum ambient temperature does not exceed 120°F FIREPEX sprinkler fittings.These guidelines apply to both the (490C),If the ambient temperature is expected to exceed this FIREPEX tee and elbow fittings, when installing,blocking may be limitation,the system must be properly protected. necessary in order to position the fitting and sprinkler correctly, Piping must be installed at least 24 in.(61 cm)from air return grilles or other openings in the ceiling. A WARNING Mounting height of sprinkler must be within sprinkler manufacturer guidelines.Failure to properly position the sprinkler can cause disruption in discharge or delay in sprinkler activation,resulting in property damage and possible loss of life. 24 7.2.1.1 Flat Plate Pendent Concealed Sprinkler Mounting For a flat-plate pendent concealed sprinkler,the bottom of the FIREPEX sprinkler fitting bracket can be located using: H=S—DW+0.35('inches) (1) where: H is the distance between the bottom of the joist and the bottom of the FIREPEX sprinkler fitting bracket S is the distance from the top of the threads of the fire sprinkler to the face of the drywall(provided by the sprinkler manufacturer) DW is the thickness of the drylivall. H _ g �y I DW Fig.7 Flat plate pendent concealed sprinkler mounting d;agiam Fig.73:F(at plate pendent conceated sprinkler mnunBng example 25 Product RENRU Submittal Product:RAUPEX"Non-Barrier Pipe Date:19-August-05 Submittal#:100RAUPEXNB Category: RAUPEX Pipes Page: 1 of: 1 C REHAU RAUPEX Non-Barrier Pipe QB Article No. Nominal A OD'In.(mm) B ID in.(mm) C Wall a in. Weight Capacity Diameter (mm) Ib/ft(kg/m) Gal*/foot(I/m) 261683 3/8" 0.500 12.7 0.360 9.1 0.070 1.8 0.04 0.06 0.0050 0.0624 261026 1/2" 0.625 15.9 0.485 12.3 0.070 1.8 0.05 0.08 0.0098 0.1222 261046* 3/4" 0.875 22.2 0.681 17.3 0.097 2.5 0.10 0.16 0.0189 0.2356 261066* 1" 1.125 28.6 0.875 22.2 0.125 3.2 0.17 0.26 0.0316 0.3939 261086 1 1/4" 1.375 34.9 1.069 27.2 0.153 3.9 0.25 0.37 0.0467 0.5827 261106 1 1/2" 1.625 41.3 1.263 32.1 0.181 4.6 0.35 0% 0.0650 0.8118 138331 2" 2.125 54.0 1.653 42.0 0.236 6.0 0.60 0.90 0.1114 1.3906 1-Average OD bnm ASTM F 876 2-Minimum Wall t from ASTM F 876 3-ID is calculated based on OD(1)and Wall t(2) *US Gallon TECHNICAL DESCRIPTION Specification English SI Standard 1 Specification English SI Standard Minimum 58 Ib/ft' 926 kg/m' ASTM F 876 4194-4355 psi 26-30 N/mm2 Density DIN 53479 Tensile @ 68°F @ 20°C Strength 2610-2900 psi 18-20 N/mm2 DIN 53455 Degree of 70-89% 70-89/ ASTM F 876 9 Cross-Linking DIN 16892 @ 176°F @ 80°C Thermal 0.24 0.41 DIN 51612 IZOD Impact No Break No Break DIN 53453 Conductivity BTU/(hrft°F) w/(m°K) Res. Linear Exp. 9.33 x 10-4 in/ft°F @ 68°F 0.14 mm/(m°C)@ 20°C DIN 42328 Temperature -40°F to 200°F -40°C to 93°C N/A 1.33 x 10-3 in/ft°F @ 212°F 0.2 mm/(m°C)@ 100°C Working Range 87,000-130,500 psi 600-900 N/mm2 Roughness e=0.00028 in a=0.007 mm N/A Modulus of @ 68°F @ 20°C Max.Short- 150 psig @ 1035 kPa @ Elasticity DIN 53457 term Exposure 210°F(48 hr) 99°C(48 hr) ASTM F 076 43,500-58,000 psi 300-400 N/mm2 @176°F @ 80°C UV Resistance 15 days 15 days PPI TN-33 FUNCTIONAL DESCRIPTION RAUPEX Non-Barrier pipe is manufactured using REHAU's high-pressure peroxide method for cross-linked polyethylene (Engel method, PEXa).All RAUPEX Non-Barrier pipe meets or exceeds the requirements of ASTM F 876,F 877,CSA B 137.5 and PPI TR-3,and is certified to NSF Standards 14/61. RAUPEX Non-Barrier pipe also meets the requirements of NSF P 171 and ASTM F 2023 for chlorine resistance. RAUPEX Non-Barrier pipe is produced in REHAU's ISO 9001 certified manufacturing facilities. *These pipes are certified by UL to UL 1821 and by ULC to ULC-ORD C199P for NFPA 13D fire protection applications. RAUPEX Non-Barrier pipe is rated for continuous operation of 160 psi @ 73.4°F(1105 kPa @ 23°C),130 psi @ 120°F(900 kPa @ 49°C),100 psi @ 180°F(690 kPa @ 82.2°C)and 80 psi @ 200°F(550 kPa @ 93.3°C).It is compatible with brass crimp ring fittings certified to ASTM F 1807, RAUPEX compression nut fittings, and EVERLOC compression-sleeve fittings certified to ASTM F 2080 and CSA B 137.5. Use of RAUPEX Non-Barrier pipe in heating systems requires corrosion protection and/or isolation by using a heat exchanger or non-ferrous components throughout the system. The information contained herein is believed to be reliable,but no representations,guarantees,or warranties of any kind are made as to Its accuracy,suitability for particular applications or the results to be attained therefrom. Before using,the user shall determine suitability of the information for user's intended use and shall assume all risk and liability in connection therewith. Installation shall comply with local codes where applicable. To the extent permitted by law,REHAU DISCLAIMS ALL WARRANTIES,EXPRESS OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. POLYETHYLENE CTS PIPE FASTENER Item#Submitted 555 series Tube Talon" Job Name SPECIFICATION Location Sioux Chief 555 Series Tube Talon'CTS pipe fasteners shall be used where Engineer necessary to secure CTS tube in piping systems.Fastener shall be 100% Contractor corrosion proof and U.V.resistant.Fastener shall be impact resistant to O'F, 130# TAG and be able to withstand continuous temperatures up to 160"F.Fastener shall have a preloaded nail,which shall be rust resistant,zinc plated yellow irradite. Preloaded nail shall have a continuous ring shank to provide a more permanent installation.Fastener shall snap onto CTS tube for easy installation,and shall allow for expansion and contraction of tube with less noise.Fastener shall be designed to avoid tube damage if nail is over driven. MATERIALS fastener body:High density black polyethylene;100%corrosion proof; U.V.resistant;impact resistant to 0°F;max temp:160°F continuous. nail: Rust resistant;zinc-plated yellow irradite;continuous ring shank. MAXIMUM LOAD RATING 555-1:3 lbs. 555-z 555-2:5 lbs. 555-3:8 lbs. 555-4:12 lbs. APPROVED USES Manufacturer has approved the Tube Talon for use with:copper tube,CPVC tube, PEX/PB tube,CSST lines,flexible gas tubing,plastic/steel conduit,low voltage DataCom cable. INSTALLATION Manufacturer suggests the Tube Talon be installed in alternating directions (so that the fastener's nail is on alternating sides of the tube being fastened)to ensure secure installation.Install fasteners at intervals described in local plumbing code for the type of pipe or tube being fastened. E ® ° To install IPS tube,use the next larger size fastener,e.g.if you are fastening 1/2 IPS tube,use a 3/a"fastener. 1 B DIMENSIONS: 555-1 555-2 555-3 555-4 A A: width 0.848" 1.125" 1.375" 1.6875" F B: height 0.735" 0.875" 1.1875" 1.4375" C: depth 0.375" 0.375" 0.4375" 0.5" J D: nail length 1.625" 1.625" 2.125" 2.375" O C E: hook height 0.468" 0.5625" 0.75" 0.9063" 1 F: width to center of tube 0.5" 0.6563" 0.75" 0.9375" Create Item Number 555-A e.g.555-3=Tube Talon for 3/4"CTS piping A TUBE SIZE ❑ 1 3/8"CTS ❑ 2 1/2'CTS ❑ 3 3/4"CTS ❑ 4 1"CTS Sio=Chllef Sioux Chief Manufacturing Company•tel:1-800-821-3944•www.siouxchief.com•fax:1800-758-5950 1108 �s PVC & CPVC TRUE UNION 2000 VALVES TU2000-2-0408 One of the Most Versatile, Compact Valve Designs Available Spears'True Union 2000 Ball Valves,3-Way Ball Valves and Ball Check Valves provide maximum versatility with fully interchangeable valve cartridges.Provides for easier system design modifications and upgrades in multiphase projects,or anywhere changes in valve types are desired.Simply exchange any True Union 2000 valve in-line using existing union nuts.Also mates with Spear 'new Schedule 80 Unions and Diaphragm Valves.All True Union 2000 valves feature a low profile, compact design for minimal space requirements.Available in PVC or CPVC with choice of EPDM or Dupont Dow Viton'O-ring seals and socket,flanged,spigot or optional Spears®patented Special Reinforced(SR)threaded end connectors.Additionally, Spearsi°offers valve Retrofit Kits for easy in-line replacement of other valves and factory installed Actuation Packages.Assembled with silicone-free lubricant. True Union 2000 Industrial Ball Valve • Multi-featured Industrial Grade • Built-in Handle Lockout • Fully Serviceable,Replaceable Components • Safe-T Blocked"'Seal Carrier-Full Rated Pressure • ISO Pattern Actuation Mounting Option • Spears' Dual O-ring Safe-T Shears'Stem • Self Adjusting PTFE Floating Seat Design • Sizes 1/2"-4"pressure rated to 235 psi @ 73°F, sizes 6"-8"and all flanged to 150 psi @ 73°F • NSF Certified for Potable Water Use • Also Available in SPEARS®LXTTm High Purity, Low Extractable PVC Material • Produced in IPS sizes 1/2"-6"with Socket, Flanged,Spigot or SR Threaded End Connectors True Union 2000 Industrial 3-Way Valve 8"with Socket and Flanged End Connectors • Industrial Grade,Multiport,Diverter,L-Pattern& T-Pattern configurations Vertical 3-Way or Horizontal Diverter(shown) • Built-in Handle Lockout • Fully Serviceable,Replaceable Components • Safe-T Blocked®Seal Carrier-Full Rated Pressure • ISO Pattern Actuation Mounting Option • Spears'-Dual O-ring Safe-T Shear'Stem • Self Adjusting PTFE Floating Seat Design • Sizes 1/2"-2"pressure rated to 235 psi @ 73°F, sizes 2-1/2"-4"and all flanged to 150 psi @ 73°F • NSF Certified for Potable Water Use • Produced in IPS sizes 1/2"-4"with Socket, Flanged,Spigot or SR Threaded End Connectors PROGRESSIVE PRODUCTS FROM SPEARS® OLPCB y INNOVATION&TECHNOLOGY yea ie`is'o rvJrH 0v�I Visit our web site: 9Op1 �••• • Avoid contact with eyes. Splash-proof chemical goggles are recommended. • Review the Material Safety Data Sheet (MSDS) and the important product information provided on the label for Spears'FS-5 One-Step Low VOC Solvent Cement. Failure to follow the above recommendations could result in death or serious personal injury. Listings,Approvals,Application&Use Spears' FlameGuard® CPVC Fire Sprinkler Products are fully tested and approved for use in wet pipe fire sprinkler systems by Underwriters Laboratories Inc., FM Global, and the Loss Prevention Certification Board. Spears° FlameGuard® CPVC Fire Sprinkler Products are approved for use in low pressure dry pipe or pre-action systems by Underwriters Laboratories Inc. Spears°FlameGuard®CPVC Fire Sprinkler Products are listed by NSF® International for use in potable water systems. For specific listing information not covered in this manual concerning Factory Mutual,The Loss Prevention Certification Board or NSF® International, please contact your nearest Spears®Regional Distribution Center. NOTICE: National Fire Protection Association (NFPA) Standards 13, 13R, and 13D must be referenced for design and installation requirements in conjunction with this manual and all local codes. CAUTION: Spears® FlameGuard° CPVC Fire Sprinkler Products are NOT listed for outdoor applications. Outdoor installation could result in product failure and property damage and will not be covered under the Spears® FlameGuard°CPVC Fire Sprinkler Products warranty. CAUTION: Spears® FlameGuard° CPVC Fire Sprinkler Products are to be used in wet pipe systems only, except as provided for dry pipe or pre-action systems in this manual. A wet pipe system is one that contains water and is connected to a water supply system so that the water will discharge immediately when the sprinkler is opened. A low pressure dry pipe or pre- action system is a piping system containing air or nitrogen under pressure that is release with the opening of a sprinkler which activates a special dry pipe valve allowing water to flow into the piping system and to the open sprinkler. WARNING: Spears®FlameGuard®CPVC Fire Sprinkler Products must never be used for distribution of compressed air or other gases except as provided for under Low Pressure Dry Pipe and Pre-action Systems specified in this manual. Failure to follow this warning could result in product failure, property damage and severe personal injury or death. Light Hazard Occupancies Spears'FlameGuard®CPVC Fire Sprinkler Products are UL Listed for use in Light Hazard Occupancies,as defined in the NFPA 13. In accordance with NFPA 13,2002 Edition paragraph 6.3.6.2,"Pipe or tube listed for light hazard occupancies shall be permitted to be installed in ordinary hazard rooms of otherwise light hazard occupancies where the room does not exceed 400 square feet". NOTICE: Local jurisdictions must approve of this exception. Residential Occupancies Spears®FlameGuard°CPVC Fire Sprinkler Products are UL Listed for use in: Residential occupancies up to and including four stories in height, as defined in NFPA 13R. Residential occupancies, as defined in the Standard for the Installation of Sprinkler Systems in One and Two Family Dwellings and Manufactured Homes, NFPA 13D. FG-3-1010 ©2010 Spears®Manufacturing Company Page 7 Revision 1/21/2011 Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe C US LISTED Size Range — 3/" through 2" Material — Carbon Steel, Pre-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. 1 Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type B A of installation. • The "Stand-Off" design eliminates the need for wood block extension. C • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket \� eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling \ tapping screws. �( � J • UL Listed as a hanger and a restrainer for fire sprinkler piping. a Approvals—Underwriters' Laboratory Listed in the USA(UL)and Canada(cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2)1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig.28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed 1 \ Nuts when used as a hanger and restraint. Use one Fig.27B Speed Nut on the upper + installed screw when used as a hanger only. I Order by — Figure number and pipe size. Pat.#7,455,268,Pat.#7,832,248 "N70 C ) (1)REQUIRED FIG— HIGH SIDE (2)REQUIRED \ of HANGERAI Dimensions •Weights HANGER APPLICATION HANGER&RESTRAINT Pipe Approx. APPLICATION Size A B C Wt. rroa 3/4 31/32 2 31/2 .180 _ 1 35/16 23/16 31/2 .210 11/4 35/8 23/9 31/2 .225 (-T- 11/2 4 21/2 31/2 .310 FIG.28-� _-� 2 41/2 211/18 35/8 .340 -F1028 F10.2B FGM OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.toko.com FOR SMALL PIPE E POTTER `'SR-SFG VANE TYPE WATERFLOW ALARM SWITCH R The Symbol of Protection WITH RETARD AND GLUE-IN UNION CUL,UL and CSFM Listed,CE Marked,NYMEA ACCEPTED Service Pressure: Up to 175 PSI(12,07 BAR) err*"•'.::-�` -� Minimum Flow Rate for Alarm: 8-10 GPM(30-38 LPM) ••� Maximum Surge: 18 FPS(5,5 m/s) Enclosure: Die-cast,red powdercoat finish No.1113555:Cover held in place with tamper resistant screws No.1113600- Tamper:Cover incorporates micro-switch. Cover Tamper:Activated by cover removal. Cover Tamper Switch Contacts:One set SPDT,Rated at 250VAC. Cover Tamper Switch Terminations:8"22AWG wire leads. Contact Ratings: Two sets of SPDT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Usage: Listed CPVC plastic piping systems manufactured by Central Sprinkler Corp.,Grinnell Sprinkler Corp.,Spears Manufacturing Co.,and IPEX(Scepter). Fits pipe sizes-1",1-1/4",1-1/2"and 2" US Patent No.6,471,255 Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket Stock No. 1113555 and die-cast housing. 1113600 W/TSK • For NEMA 4/IP55 rated enclosure-use with appropriate conduit Service Use: fitting and/or plugs. Automatic Sprinkler NFPA-13 • Temperature range:40°F to 120'F(4,5°C to 49'C) One or two family dwelling NFPA-13D Caution: This device is not intended for applications in explosive Residential occupancy up to four stories NFPA-13R environments. National Fire Alarm Code NFPA-72 The Model VSR-SFG is a vane type waterflow switch for use onwet sprinkler operation of the VSR-SFG. See Fig. 1.)Wait 2 to 4 hours to allow the systems using CPVC plastic fittings manufactured by Central Sprinkler glue to dry before attaching the VSR-SFG to the 1"male fitting.Select the Corp., Grinnell Sprinkler Corp., Spears Manufacturing Co., and IPEX proper paddle for the pipe size and type of TEE used.See Fig.3 and Fig.5 (Scepter)that use 1",1-1/4",1-1/2"or 2"pipe sizes.It is equipped with a for instructions on how to change paddle.Verify that the o-ring is properly union to accommodate installation in confined spaces. positioned in its groove.Hand tighten the nut on the union after orienting the The unit contains two single pole double throw snap action switches and an device in the appropriate direction to detect waterflow as shown in Fig.2. adjustable,instantly recycling pneumatic retard.The switches are actuated CAUTION:Do not over-tighten the union nut,hand tighten only! when a flow of 8-10 gallons per minute(30-38 liters per minute)or more The vane must not rub the inside of the TEE or bind in any way.The stem occurs downstream of the device.The flow condition must exist for a period should move freely when operated by hand of time necessary to overcome the selected retard period. INSPECTIONANDTESTING:Check the operation ofthe unit by opening INSTALLATION:These devices maybe mounted on horizontal or vertical the inspector's test valve at the end of the sprinkler line or the drain and test pipe.On horizontal pipe they should be installed on the top side of the pipe connection,if an inspector's test valve is not provided. where they will be accessible.The units should not be installed within 6"(15 cm)of a valve,drain or fitting which changes the direction of the waterflow. If there are no provisions for testing the operation of the flow detection The unit has a 1"male fitting for gluing into a CPVC plastic TEE. device on the system,application of the VSR-SFG is not recommended or advisable. Loosen the union nut and separate the V male fitting from the VSR-SFG. Glue the 1"male fitting into the TEE following the TEE manufacturer's The frequency of the inspection and testing and its associated protective instructions for preparation and gluing of CPVC piping systems.(NOTE: monitoring system should be in accordance with the applicable NFPA The V male fitting must bottom out on the stop of the TEE for proper Codes and Standards and/or authority having jurisdiction(manufacturer recommends quarterly or more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT#8800009-REV P PAGE I OF 2 MFG.#5401062-11/05 FOR SMALL PIPE E) POTTER VSR-SFG VANE TYPE WATERFLOW ALARM SWITCH ® The Symbol of Protection WITH RETARD AND GLUE-IN UNION FIG.1 FIG.2 APPROX.RETARD SETTINGS(IN SEC.) Retard Adjustment: 0 A B C D E (MINIMUM g:LEARArIGE To change time,turn knob(either direction) 0 10-25 20-40 35-55 50-70 60-90 REOUPED FOR I"MALE =ITTING INSTALLATION OR MUST BOTTOV OUT for desired time delay. Use the minimum DO NOT LEAVE COVER REMOVAL OF DEVIC=) ON STOP amount of retard necessaryt0 prevent false OFF FOR EXTENDED III P PERIOD OF TIME alarms.A"B"setting is usually adequate for this.Factory set at`B". RETARD ADJUSTING (WHITE) COM. FIG.3 KNOB (RED) N.O. (BLACK) N.C. DIRECTION RFLOW F MOUNT SO /\ CAUTION: INSURE ARROW IN THAT 0-RING IS BASE POINTS IN 0-RING GROOVE O DIRECTION BEFORE INSTALLING OF WATERFLOW NO 8JSHINGS. DWG.�I063-3 SWITCH. n ADD P .;R DWG. #106'-< Important: ACAPT RS CD ARE PERMITTED 7 paddles are furnished with each unit 1"MALE to accommodate the various sizes and RUN OF THE FITTING ON manufacturers of TEES.The paddles have TEE MAY BE ALL SIZES Glue the I"male fitting into the TEE following 1". 1 1/4". the TEE manufacturer's instructions for raised lettering that show the pipe size and I 1/2"GR 2" preparation and gluing of CPVC piping the TEE manufacturer they are to be used systems.Wait 2 to 4 hours to allow the glue with.The proper paddle must be used.The DI ERTIONWOF O DWG. N 1062-2 to dry before attaching the VSR-SFG to the paddle must be properly attached(see Fig.3) I"male fitting, and the screw that holds the paddle must be Shown with optional Cover securely tightened. romper swam xa. FIG.4 TYPICAL ELECTRICAL CONNECTIONS NOTES: COVER TAMPER 2SETSOFNORM— .1.1roNTACIS —FERFfAWZONE EOLR FROM 1. The model VSR-SFG has two SWITCH CLOSEONALARM ON FIRE PANEL FIRE PANEL switches,one can be used to operate a (SHOWN WITH central station,proprietary or remote COVER IN PLACE) signaling unit,while the other is used to operate a local audible or visual annunciator, b Ib U—c.ANo N.O.MAR1tL'Gs ON ......... 2. For supervised circuits see"Switch THESWDCHAREFORAN ALARM ORROTAC BELL Terminal Connections"drawingv and C N.O. N.C. CONDITION. O (WHT) (RED) (BLK) NEGATIVE DC OR:! Tf1ECONTACtRAREREVERSED NLOTRALAC caution note(Fig.6). WHEN THE DEVICE IS IN THE N'ORMALCO.NDITION. .i.... FIG.5 GRINNELL TEE FIG.6 SWITCH TERMINAL CONNECTIONS TEE's manufactured prior TEE's manufactured CLAMPING PLATE TERMINAL to 5/99 after 5/99 110.1 11 1 -d OJ�Oo\fit' Dwcx vva NOTICE: DWG./1062-I As of 5/99 Grinnell has changed the design of their TEE fittings.The new fittings CAUTION: will require the use of the standard paddle,while you will still be required to An uninsulated section of a single conductor should not be looped around the use the paddle marked Grinnell on all fittings manufactured prior to this date. terminal and serve as two separate connections.The wire must be severed,thereby Failure to install the correct paddle could cause the device to malfunction or providing supervision of the connection in the event that the wire becomes operate improperly. dislodged from under the terminal. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges,trapped air,or short retard times,waterHow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF,deluge,or chemical suppression systems. PRINTED IN USA MKT.#8900009-REV P PAGE 2 OF 2 MFG.#5401062-11105 SYSTEM .SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert°Advance outdoor audible visible products SPECTI AJCrt are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed devices,SpectrAlert Advance can meet virtually any application Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. Field-selectable candela settings:15,15/75,30,75,95,110,115,135, 150,177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes,and Automatic selection of 12-or 24-volt operation at 15 and 15/75 horn strobes for wall applications include a variety of features that candela increase application flexibility and simplify installation.First,field- Rotary switch for horn tone and three volume selections selectable settings,including candela,automatic selection of 12-or 24-volt operation,horn tones,and three volume options enable Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. Rated from—40"F to 151°F Universal mounting plate with an onboard shorting spring that Next,SpectrAlert Advance devices use a universal mounting plate tests wiring continuity before devices are installed for both wall and ceiling applications.This mounting plate includes Plug-in design with minimal intrusion into the back box an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without -Tamper-resistant construction mounting the devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill LIS holes for screw-in mounting.Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch FM MEA eDo-'a5a:)s c°um�,s; :t approved �53'aar°^",°' knock-outs at the back.A screw-in NPTplug with an O-ring gasket APPROVED ;.h:mefn°6ei) s,,+.._,,,,,,<,a)e,, 302357) VCA453-054 7 35-165313e(�° chim ) for a watertight seal is included with each back box. LOWN-IN INSULATION It Requires insulation be moved up above the sprinkler pipe to 0 0 0 0 allow heat from the conditioned O O O O O O space below to transfer into the O O O O O O O 0 0 0 attic space and keep the pipe O O O O O _ O O O O warm. 00000000 �0000000 00000000 0000000 O O O O O O O TRAPPED AIR SPACE 10 MIL PLASTIC TENTED OVER PIPING (STAPLE BATTS INSULATION (TRAPPED AIR SPACE OR PLASTIC"TENT") BATT INSULATION TENTED OVER PIPING TENTING TENTING(Fig.1) C TENTING A common method used for insulating sprinkler piping sections that are run within any unconditioned space, such as an attic or an exterior wall. It Requires insulation be moved up above the sprinkler pipe to allow heat from the conditioned space below to transfer into the attic space and keep the pipe warm. For it to be effective the insulation must be continuous over the pipe, with the assumption that any heat lost through the insulation will be replaced by the conditioned space. Even in moderate climates, the sprinkler system needs to be protected from freezing. This is done by keeping the sprinkler pipe inside the insulation envelope. Figure 1 shows tenting over residential sprinkler pipes to prevent blown insulation from getting between the pipe and building's warmth.