HomeMy WebLinkAboutPermit File BLD-2021-0308 4708 Queen Ann Way (11)REVISIONS I BY 6-3-21 1 TP A B c 4'-0" I 6'-O" 12'-I1" I- N WSP WSP WSP I O BRACED WALL FLAN SCALE: 1/4" = V-O" 3'-0" PRESCRIPTIVE WALL SRACING PER 2015 RIC 602.10 BRACED WALL NOTES: 1, SEE WALL PANEL DETAILS FOR REQUIRED BRACING a EACH WALL/SECTION 8 FOR BRACING PROVIDED a EACH BWL, ADJUSTMENT FACTORS 6 CALCULATIONS PERFORMED USING "APA-The Engineered Wood Association" PROPRIETARY CALCULATOR 2, PER IRC TABLE Rro02.10.4 INTERMITTENT BRACING METHODS: METHOD GB: INSTALL 1/2" GYPSUM WALLBOARD W/ NAILS OR SCREWS a T" SPACING AT PANEL EDGES INCLUDING TOP 4 BOTTOM PLATES: FOR ALL BRACED WALL PANEL LOCATIONS, EXTERIOR SHEATHING NAIL OR SCREW SIZE, SEE TABLE R602.3(1): FOR INTERIOR GYPSUM BOARD NAIL OR SCREW SIZE, SEE TABLE R-102.3.5 3. PER IRC TABLE R(o02.10.4 SHEATHING METHODS: METHOD WSP: INSTALL MINIMUM 3/0" WOOD STRUCTURAL PANEL W/ 6d COMMON NAILS a (o" SPACING PANEL EDGES AND 12" SPACING FIELD --BUILDER TO EXAMINE EXISTING CONSTRUCTION DURING SIDING REMOVAL AND ADD NAILING AS NEEDED 9, BRACED WALL LINE CALCULATIONS HAVE APPLIED AN ADDITIONAL ADJUSTMENT FACTOR OF 1.4 TO ALL LINES, PER 2012 IRC r602.10.3(4) TO ALLOW A MAXIMUM BWL SPACING OF UP TO 35'. l "> 30 feet and < 35 feet" - IRC rro02.10.3(4) --MAIN ROOM = 564 S.F. WSP Q 3 WSP O 9, LU Z 4 (V Q OU N J O 3 Zzw Zz Lu z � � Q� 0 MD MILLENNIUM DESIGN 360-424-3334 troy ID drawnbymillsnnium.com DRAWN TP/DW DATE 8-19-20 JOB NO, 19-360 3 OF: BUILDER TO VERIFY ALL DIMENSIONS. CONSTRUCTION TO COMPLY WITH THE 2010 INTERNATIONAL RESIDENTIAL CODE AND ALL APPLICABLE LOCAL, STATE AND FEDERAL BUILDING CODES.