Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2022-0927 1604 Latitude Circle
City of Anacortes Invoice/Permit#: BLD-2022-0927 904 6th Street Applied date: 12/06/2022 P.O.Box 547 , WA 98221-0547 Issue date: 12/06/2022 Anacortes r �► Expire date: 06/03/2024 (360) 293-1901 Job Address: 1604 LATITUDE CIR Permit Type: PV Solar Permit ANACORTES WA 98221 Project: APN: Remarks: Install a PV solar rooftop system, 5.55kW, 2 circuits. Owner: DENISE GECHAS Contractor: SOLGEN POWER Address: 1604 LATITUDE CIR Address: 5715 BEDFORD ST ANACORTES WA 98221 PASCO WA 99301 Phone: (360) 899-9859 Phone: (509)931-1663 License M General Information: Fees: Building Valuation 4773 Building Permit Fee 111.25 Plan Review Fee 72.31 State Building Code Fee Resi 6.50 Total Calculated: 190.06 Deposits/Receipts: 0.00 Total Due: 190.06 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law,or of any order, proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUE PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT r Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6th Street,Anacortes WA 98821 � 4� Phone: (360)293-1901 FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: 1604 Latitude Circle Anacortes Washington 98221 APNP133677 Subdivision/Lot#: Zoning Designation: Lot area (size): zone 5 sq.ft. 2. TYPE OF PROJECT Mf New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) ❑ New Duplex ❑ Attached to Primary Unit ❑ Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building ❑ Fence or retaining wall or duplex (new/repair) ❑ Other: Project Summary: PV Solar Roof Mount Installation,5.55kw,2 circuits Project Valuation: $ 4,773 3. PROPERTY OWNER INFORMATION Name: Denise Gechas Phone: 2629602287 Address(Street,City,State,Zip): Email Address: 1604 Latitude Circle Anacortes WA 98221 dmgechas@yahoo.com 4. CONTRACTOR INFORMATION Name:*Solgen Power,LLC Phone: 8557091181 Contractor's Business Licenses State License#: City License#: *All Contractors&Subcontractors must have a valid City SOLGEPL820BE 604182705 of Anacortes business license prior to doing work in the Expiration Date: Expiration Date: City 01/05/24 3/21/23 Address(Street City State,Zip): Email Address: 5715 Bedford St.Pasco WA 99301 permitting@solgenpower.com 5. CONTACT PERSON Select one person the city will contact for anything related to this project: W Applicant ❑ Property Owner El Contractor ❑ Other list below Name: Ingrid Lomera Phone: 8557091181 Address(Street,City,State,Zip): Email Address: 5715 Bedford St. Pasco WA 99301 permitting@solgenpower.com Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 5 of 18 GAT Y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6th Street,Anacortes WA 98821 \�'�yq,cow� Phone: (360)293-1901 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write"no lenders"on the Name Line below. Name: n/a Phone: Address(Street,City,State,Zip): Email Address: 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technically complete and sufficient for staff review. I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. I understand and acknowledge that I could be responsible for providing as-built drawings (on paper or electronically) as part of the project's certificate of occupancy process. I understand and acknowledge that Special Inspections could be required as part of my project,and if needed I will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. I understand that if permits are reviewed concurrently such as design review,site plan,traffic concurrency, etc.,any required revisions to one permit may affect the entire plan set and could add costs and time to the project. I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects,true, correct, and complete to the best of knowledge and belief. Y • 12/02/2022 Signature Date Ingrid Lomera Printed Name Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 6 of 18 ,TY o City of Anacortes Photovoltaic System Permit Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic (PV) systems, including roof top arrays, ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor & Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code (Current Edition) International Fire Code (Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot, with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE: The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review. To Be Completed By the Applicant Project Address: 1604 Latitude Circle Anacortes WA 98221 Project Applicant: Solgen Power, LLC Applicant Email:permitting@solgenpower.com Phone No.:8557091181 Site Owner Name: Denise Gechas PV System Description: PV Solar Roof Mount Installation, 5.55kw, 2 circuits Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or ❑ ❑ townhome. X 2. PV System is designed for rooftop of house in general compliance with applicable ❑ ❑ codes. X 3. Mounting system is engineered and designed for PV. )p ❑ 4. Rooftop is made from light weight material such as shingles. x1 ❑ 5. PV system will be permitted and pre-approved by Labor& Industries Electrical ❑ ❑ division. X 6. To address uplift, panel are mounted no higher than 18"above the surface of the EX ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings, race ways,and all other )U ❑ appurtenances weight no more than one of the following. IF Yes, indicate which: ❑ No more than three and one half(3.5 pounds per square foot(PSF) ❑ Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF ❑ Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many Ex ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. x7 ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to ❑ ❑ pitched roofs). X Comments: vi By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑Yes ❑ No SOLGr- N I,' P O W E R December 03, 2022 Subject: Proposed Solar Panel Installation Denise Gechas Residence, 1604 Latitude Circle,Anacortes,WA To Whom it May Concern, Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar panel installation at the above-referenced address. The purpose of our review was to determine the structural adequacy of the existing roof. Based on our review and analysis of the available information, and in accordance with governing building codes, it is our professional opinion that the existing structure is permitted to remain unaltered for the proposed solar installation. Design Parameter Summary Governing Building Code: 2018 Washington Building Code (2018 IBC) Risk Category: II Design Wind Speed: 110 mph (per ASCE 7-16) Ground Snow Load: 15 psf Roof Information Roof Structure: 2x4 Manufactured Trusses @ 24" O.C. Roofing Material:Asphalt Shingles (1 layer) Roof Slope: 18 degrees Roof Connection Details RT Minis into 2x rafters or truss top chords at 48" O.C., install per design drawings and manufacturer specs Locations per design drawings Note:Required embedment length excludes the tapered tip of the screw,and embedment into sheathing. Analysis The proposed installation complies with the requirements of WAC Section 51-51-03240 R324.4 (Exception) and is therefore deemed adequate to support the load of the rooftop solar system. Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3) the total dead load of all items is less than 4 psf(actual value is approximately2.65 psf);4) Modules are not mounted more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof-framing members and does not exceed 50 Ibs at any point. Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading has been used to verify the adequacy of the connection specified above. Connection locations should be in accordance with design drawings. Conclusion The roof structure need not be altered for either gravity or lateral loading. Therefore, the existing structure is permitted to remain unaltered. Connections to the roof must be made per the "Roof Connection Details" section above. Copies of all relevant calculations are enclosed. Limitations and Disclaimers The opinion expressed in this letter is made in reliance on the following assumptions: the existing structure is in good condition; the existing structure is free from defects in design or workmanship; and the existing structure was code-compliant at the time of its design and construction.These assumptions have not been independently verified, and we have relied on representations made by the property owner and his or her agents with respect to the foregoing.The undersigned has not inspected the structure for patent or latent defects. Electrical engineering is beyond the scope of this analysis. Solar panels must be installed per manufacturer specifications. Structural design and analysis of the adequacy of solar panels, racks, mounts, rails, and other components is performed by each component's respective manufacturer and the undersigned makes no statement of opinion regarding such components. This letter and the opinions expressed herein are rendered solely for the benefit of the permitting authority (city or county building department), and may not be utilized or relied on by any other party. If you have any questions or concerns, please contact our office at (855)-709-1181, or email me directly at Trevor.Jones@solgenpower.com. Sincerely, Trevor A.Jones, P.E. OR sO�FS h� O h 2 J. b 201148 8 Q7 RFGIs \� ASS/ONALEN� 03/12/2022 SOLGrzN P O W E R WA State Exception Criteria - Calculation This calculation justifies the additional solar load by showing the solar dead load at each attachment is less than 50 Ibs (WAC 51-51-03240, R324.4, Exception Criteria). Connection Demand Spacing perpendicular to rail 32.5 in 1/2 panel length Spacing parallel to rail 48 in Max spacing Solar Dead Load 2.65 psf Solar DL Point Load 28.70833333 Ilbs OK SOLGr- N P O W E R RT Mini Connection Calculation This calculation justifies the connection of the solar panels to existing roof members, by showing the connection capacity is equal to or greater than the uplift force demands. Connection Demand Spacing perpendicular to rail 32.5 in 1/2 panel length Spacing parallel to rail 48 in Max spacing Effective Wind Area on each connection 10.8 ft2 Roof Angle 18 degrees ,OLAROOFINO/ Wind Speed 110 mph LFOOT FTECH Exposure Coefficient, K, 0.82 6 Topographic Factor, K,t ROOINI 1 MINI CHIKO Directionality Factor, Kd 0.85 7#R.iI Elevation Factor, Ke 0.99 Velocity Pressure, q, 21.5 psf Mont through roofsheatMng into existing rafters Zone 1 Zone 2 Zone 3 GCp(max) 1.80 2.57 2.57 Exposed Panels? (YE= 1.5) No No No Pressure Equalization Factor,ya 0.79 0.79 0.79 Uplift Force 30.4 43.3 43.3 psf Max. Uplift Force/Connection (1.0 WL) 328.8 469.1 469.1 Ibs ASD Factored (0.6 WL) 197.3 281.5 281.5 Ibs Solar Dead Load (0.6 DL) 17.2 17.2 17.2 Ibs Max. Uplift Force (0.6 WL-0.6 DL) 180.1 264.3 264.3 Ibs Connection Capacity Connection Type RT Mini into 2x Rafter Total Allowable Capacity 447.0 Ibs (per manufacturer) Compare ASD Factored Demand to Capacity Demand 264.3 Ibs Capacity 447.0 Ibs Result Capacity exceeds demands.Therefore,connection passes. 1 2 3 4 5 vi = z p a O _ a ~ } UO Ow Q z O - o � w� z ? wz w z w Y U z� LLf c� w_ pw z � 0v! OzW mU �nw Zo LL z a O U w ly W QLU � QU � � � z w = � w0WU W � Ja = Q > z O w = z Qz WO o o N a O vOf 0LLJ n � U Z00- w � � CO a � 0Q Q Q N z0 zzJ � W0 O 0E- < O W ww 25 ~ Z W w Z F � wppci viWcnOfw � U 000 Yw (D = N w0zQ2ix � wm canz W w O � � UJ � = i� Q U N N J = � Z � °� zww � rv - wzz0 wviH UQ zz zzz p Q N OUz00wz00 j � Za v» c) c~npo O » LLLLwZm - Q ~ w (D H = � Z0XO = w � O Owzw �LLJ � � W � wzZOOO < Uw0 Z_ p Q O7 LL] HLuOpJ � F- pzF- H � 2CDcn - QOQ p2HaYOf F- ZU H Q Z 0m — w -j5Eww0y0Wwz — Jw = p JZ � JU � � UQU Z Q w LLI � Ymh- OO 2 � [if Z) WDF- W 0 > -1 E: wJF- 0 U 11 U w 2 w p H O H LLJ� p p w O f 0 L U /� Q W �• � O0 W F- W � h- 0_ -1z ZLLCJJU) w (n } JOJ F- W J W U J W LU GO J = } (D � Z) � J O w O a W U >- Q > >- Z J w Q U) 0- J = m J O J c 0- U) m v�,\ - M In (c r z LLI W � � woacnaUOUcn � ? cn > ? cnaamLL ? cna �aUw Z a I i c i cri v 6 C.6 ti ao o; z a U o o O LLB } � p p � p L2U v/J w aWLL D � p N LU O O VU^ 0 > F- Z ~ z > W = 06 V)Z Z LLJ O J H W O QO = mZ mw — pp � O � C° -- Co CN � �= 7Z0pp >. (DZ0Q_ �Z - QOa � 0' Z p W pa � Wo +� � Z Qm0 ? Q pwzOfLLM3: CD a wQU > F- p Z UN O LL O Z NZ OZ aJ — O Z a C-� CLLJL U H � W $Q Q Qz = 0coU c CO Q_ UZ ZWO � p = dOJ m0 �QO CJH 0 5w > ww U w pZ 0pm wQ0 Z W CD � p Q �0E- WZwm U awwQ = wppz = O6' ZZ Q � WZ 0- - - � = aLLCo2LL02Z D F- gypO zrwaOf Wp co F- — Wp0 _ W -1 > — . aoz U O ap z � Q N LL mO � JWLLJJQUF � aOZ7fnWWJapLLaT0Z � Z -i - F- Zf- W W W XX W D2 W w2OaZNJN WpUp LL Q UJ Wz - z QZ) DZ � Oa2Z0W mZ Lu 0Z) 0_ � 02 < LLJ � M: U p = I Ln p p = p00 W z = = z w ° F- ° F- = C) 0 w= � �LLI � w 00 o >- � o o �� pWnHWh- m _ aQJWaan - 2 < MD2iW0 < Y— r•V^W(^�W- - Uaco � N co I- r w M CO W p M 0o' m Oa. ga zw - rn CW.7o0 0 U O �; LO U) Q_ p w w U) l zw wp ? w ZW0F _ 0 � ODULLZ � Xcw � i I W Zf- Z d' wp � O Z W W W Z Z o Q = m 0F oa = w 2awa0 � W � � � w � ZONQ � a 000000 W ~ Z � H Z 4 O z O U" p Q W Z W WWW0m � H2O p o J 2 Cn r � = O rl O U LLJ h h- QjLL1pU � (n i LLl QwwW z � w0 Um � wwpww Q . U W = 0 0 m a > Z ti• , o U, J z J W W w W ry LL.I f z = JOJ �LIJ ZQ_ Z LL) "� 0 Y.� - Vz = z = = 0w0 I o WaWHU0_ U U) IJyll r �I +ui N h"# Li ui I VJl7`l7 K > .f Y." LL i • ��I1 I� _ �t a _ Z V 7 1 2 3 4 5 o Nw _ J � Q00 U II (4 N > N - z :!zZ L � _ X w N ono Z a U N d N La O U) U) N N � U) N N LLI c� z z LO o N z m O Q I — LLr) o W v o (n N O J LO Ln o J U � � o � � DOOM �Z � Q � (n (n � � X U �c3 p� �j� O W W Z �? m 2 = O W U m W o ) co Q N N LL W - Z a ¢ a U) W W W w w 0 ova CNNo �w� U � L W W m F- Z) H U) co �_ d���dd S � (� •— U- U) U 0 W C) J z � 0 P� (�n > 0 r1 col z 2 z C) Q I I I _0 U) }' CN U ~ ~ O C� LL Cam J LU U U O o + fl w ° awLLI ° o Loa a O Cl) LLI W Z W I Wp Z— F- W Qw w — H = LL = (� � ILH Zc� 0 0E- OUwZOX ? � 0 LU zwLULU2 � O � wm � = OQ = w � 0 = 0- 0 � J ~ Q 0 U) H Z O N Q w w F- — cq Z = O O O Q W Z W U LO 'IT N 2Z � U) 0o = a0 ~ QU) wUcn ~ 5 (f) 0 Q Y m � Z Z LU 0 O Waoom LU a_ F ?LU F- Z W H 0 0 0 Z zF- < W ZfnZ O = Z 2 2 0 W 0 U ? c) Qc) F- UD� U LU -j z 0 J m z � u � � w 00 woo 0 = NO o > N d (D Nw J o w w O Q w O " a W L �LL 0 � /� Q V I 0 0 N M cM QZ CA W N O Q W o OQO z s t 5 1 2 3 4 5 M Q z W `' , � D IiiQ LU -I Q U wCO Oz � O m O z ? z = w 9 LU z `LOU < Ow a o 0 Q OW oJY U N o w � Qw Q O w = JOB w N �o cnF m 00 N II 00 N N M N N co M w O =¢ Z O F O N o � O w 9 v n U C m O== on U Q Q o U W °J' 0 } / ) V H + K U J0.9 n m \/ Q @ Of N O N a O N L Z Q ~ O _h U W 0 p 0 N Y I (n N r z z z w C,4 W a s Q N K K K W m m U U U m == Z Z Z VJ ^1 oZQo Z¢ Za u W F O O Q N O ~N Lu W N 2 H f`') U \V = a = a = a O (•i w U 0Of 0 K O ~ N wO 0 0 xQ o xo�( wQ UQ UQ x (+') Ra U LL U u U u U r U �• , W ZZ Z Z LUw III Fn U Ir Ir j N 33 U U V U¢ U U w a s Z 7 In Z Z)a Z Z)N w Q�QF FF0- ¢¢ F� m W O w 0 w 0 x •� "' g?� o o Z J U U U w Q X ¢ x ¢ X w W W W U O U= rn Z Z Z 0 M 0- 0- LU w Ix a W U_ U_ U_ ° Q LL LL LL O O O W w Q¢ a$ W o v� O rn � Q zw � rn LU o CD O o N J - w L!) In 0 LIB Q IL Y uQi ua') l Q H H_ K C) L) Q m � U U (f) LU W m� ¢ z_ W of Z � W _ w Q W LL W (n LL F 00 Z ` Zc50P a- 0L: u u 000 O H W LU W 2' U U O U N Q (O N Z O J LU P7 Z ~ Z LL W C) D Z�m �� 00 �) D z W W W Z z O u u 11 11 co W 2� Q m 0 O Q 2 W LL UowW° IIz =o II � � 2 OQJ � O In N N N M J Z v Z N Z Q N Q �' LL' �M O m W ~ Z Z U)_ m=� �� z D 0 0 m Q W z W x x x U ¢ W~ ` O ww ` W 0 0U) � Q LLJ � U Q O ¢¢¢ D o U) J Moo- U � U= � N ui Q J wr WOJ�LL 6 W N D> Z U ~ Q co O > I I II I I II W Z> Y m Q OD W Z W H U U U Z w 0 z — W W W Z Q,0o� W • • �L = J O J � z � fn ILFF = � Z � Q � QWz (Az OOWa�a¢ O /O 2Z220 W0 m J W N C 0 0 2 U � Z0 -cj 2 mg Z 0 U u F Z o co K U 2C(moo O Z _ Y Z (oo�w^ ° aw¢ Z � =o z O �_j II u mN Z U lZJ�N m xX x az F <n a>-z LL W 4 W Q W W Of U~ IXW Q ZN� Z� o W 2 Z w H W z U Z 5 W of N U � oN m �' O Qga III � � o - -, az00 0 U ( WW IY —U 00 O W 2 co O LL 0 � (n Z W� _U OW O II W LL m �LL =2 wD-N7 co W � Z Q W �Z� 2O oN two OUWQ ?gWM //�� =g N� � UZ N m=H �/ z _ 0 0 Ld W cb X OO 2 mmm J a w � � N bww `. II� 0 0 o X j-j � � �fn adz W Z O� Q W L0 Z� =O Q FFFFF Q< fn ON OZNU>- WF ����� �N LU N N M.��U> UUUUU tnN O JJ Z� UUUUU m Z � (VM vQQ co Z E 5 1 2 3 4 5 U 6S W z > ow = w p a U N Q N W O N N N N N 00 Q (D m (� Z a i oq LL 4-0 U Q Ca � � L v U v � Q- U)10 +� J O) 0 C O � O W Ur � M (� 1 UJ Q CO >Q> Z W > � C�LLI 0 0 O Q J U) In 0 LO a a p * LLI W W Z w 7- Z aW W0 ? � w H = LL = 0 LLH zcn0P D- o OU Ej-Z0U LU Of cw � E z Z � � LLU o � � zm � Wzz0 � w = oQ = W ~ _0 cn FLU Z0N U Q � � O E �: 2 02 W ~ Z0HZO E a) S = OoOQWZW LL O Zn O Ln U - J W 0 W 0 ao _0 E = ZUJU LU 0 = o OO Q o � �O 0co - Cn o J0 - § o 2 O O 0E- zCn w0 O > o0maULU F- Z W H U U Z nrz= oJ LU zF- �- Qwznz = z = = Ow0 vz-:7 n Q n H U CY U OO---------------------------- T 4111 -4 Cl) m N u w COJ w m N N O � -CD>- U - c J LL �/ N Z co �' �•' 0 LO IR co o0 2ua —1 Q Q 0 0 cn r 2 O ` 1},; pz H Q O � O m CD �� O o ��� U = 9 R c� 0 C: U �, w o p U) W Z i �. Q Q D U .X �/ w m -1 a O � — Q o Z o J 0 � � •� o O 0 0 N CM 4 6 Z E b 5 1 2 3 4 5 z w o r ' O Q � . ~ u < cn > w W O < CO Z It 2 LU � W FnFn 0 O W H LU p O d z �2 X Q Q CV J Q � � c� UU) n L w w wCN m CN N N Z) w� JofOvi Q N�o — Z:) 00 00 �o w o 4 Z Uo w0 (Ifc= Q b NZ d Z a w U O w w CD o QO Z � a Z)O _ Z xU) P Z p 00 zr 0 'oO 0 0o d� reds �� R 0' o p� cn U N N C6 (a �/� (Q N c0 I� V) `D LL O N °oJ = i W CD aD 0 U � O O w 0 � � M w co � O (.0 Q Z w oo O o J LO U Ora a 0 C/) W Z W � Wp Z Qw w W- - � = LL LL �- Zcn0 OF- OUwZOX ? � OzwwwZZOo� H w m3: = O Q = W � O = � O �zJ ~ � � W � ZONQ § w W — cq LL CO zOLLJwomwU' U N = ZWO0O = 0. O ~ QmWUcn ~ = � 0 Q W m W E Z Z w o W a O O m a O > F- Z w H U U U Z C, JZJ � Z W W W 00 o z <Q - < w Z w Z 2 Z = = O w o 07 O J = U ? cnQc� � U � U Q m u W (D fV J S p 0 Q a o V) c� z Q z m _ r 1 2 3 4 5 U �cm) r � 912 z It = U wl co 1 fl-c t o a } 0 ul (� N � W N N N OQ cn Q x O L m � } (n� co _ z ~ Q Z5 p U a U O —a 0_� a� < � [7 C7 p p + Q U a C,) a V LL � v U v Z • a I� I� • d 0co > zoi 4-0, '�^ }� o s }j pa a - _ { zoo a _ J � z Q W � w p C) LL1 ! W p co co � � rn — �Z rn PAM U) IL Mom ' is41 ; Rz 0 cc Li F W Z W �' W = z W W 0 Z � W H = W = 0 LL ~ z w o P o � 0zL- z0c) U) U U) X ~ O z Z W w W o ~ � � o� D �L -1 ~ LU w 0 < � O O CO ZNQ OOQ < Wzwn U � D �7 0- z w0p0 � � 2 -�1 U ry w Q � o J LU Q Q -1O = - O U w - LL z Q Q W W W O Z w 0 0 o w 1 V ZamomI - LL ZJ �_ Z N c\lU w O W O Z H W W U W 0 rn � (D = J O J �< Lu Z d (n O0- ¢ W O ~ 2 Z 2 2 0 W 0 C0 T Z UZcnQw w0 CO Cl) Q2 0 x Q ZZ °' O � U 0 E d 0 LU U ILO m mOU 6 ww O a Zw CO O J z 2 v = z o� O O �? i Q ry J WO H O � � s Q 5SUNTECH Full Black Series 350-370 Watt 120 HALF-CELL ALL BLACK MONOFACIAL ST PXXXS - 660/Wn h b MODULE Features High power output =1 High PID resistant Compared to 158.75 mm half- Advanced cell technology cell module,the power output � and qualified materials lead to • can increase 25-30 Wp esist` high resistance to PID Excellent weak light Suntech current sorting performance I 2 process More power output in weak I 2 System output maximized by light condition,such as haze, reducing mismatch losses up cloudy,and morning to 2%with modules sorted& packaged by amperage Extended wind and snow Withstanding harsh load tests environment Module certified to Marsh Reliable quality leads to a withstand extreme wind better sustainability even in (3800 Pascal) and snow harsh environment like desert, loads (5400 Pascal) farm and coastline Certifications and standards: UL 61730 ETA (T Intertek - Trust Suntech to Deliver Reliable Performance Over Time Special Cell Design • World-class manufacturer of crystalline silicon photovoltaic modules The unique cell design • Unrivaled manufacturing capacity and world-class technology leads to reduced electrodes • Rigorous quality control meeting the highest international standards: resistance and smaller ISO 9001, ISO 14001 and ISO]7025 current, thus enables higher • Regular independently checked production process from international fill factor. Meanwhile, it can accredited institute/company reduce losses of mismatch • Tested for harsh environments (salt mist, ammonia corrosion and sand and cell wear, and increase blowing testing: IEC 61701, IEC 62716, DIN EN 60068-2-68)** total reflection. • Long-term reliability tests • 2 x 100% EL inspection ensuring defect-free modules Industry-leading Warranty based on nominal power IP68 Rated Junction Box • 98%in the first year,thereafter,for The Suntech IP68 rated years two(2)through twenty-five junction box ensures an oo Industr (25),0.55%maximum decrease from outstanding waterproof 98 Yleadingllne MODULE's nominal power output level, supports installations ar 90% warranty peryear,ending with the 84.8% in all orientations and 81 in the 25th year after the defined reduces stress on the cables. �oPo WARRANTY STARTING DATE*** High reliable performance, 1 10 25 • 12-year product warranty low resistance connectors • 25-year linear performance ensure maximum output warranty for the highest energy production. *Please refer to Suntech Standard Module Installation Manual for details. **Please refer to Suntech Product Near-coast Installation Manual for details. ***Please refer to Suntech Product Warranty for details. NSUNTECH STC STPXXXS-B60/Wnhb Maximum Power at STC (Pmax) 370 W 365 W 360 W 355 W 350 W 1039[40.911±2[0.081 989[38.94Y[0.041 Optimum Operating Voltage(Vmp) 34.3 V 34.1 V 33.9 V 3_17 V 33.5 V Drainage holes F Optimum Operating Current(Imp) 10.79 A 10.71 A 10.62 A 10.54 A 10.46 A ---------------------------------------------------------------- ------------------- ----------------- ------------------ ------------------ ------------------- Open Circuit Voltage(Voc) 40.9 V 40.7 V 40.5 V 40.3 V 40.1 V 4-05.1[00.2] Product label B - - - - - ----------------- ----- - --- ---- - ---- - -- - --- ----- - -- - ---- ----- -- - ----- Grounding hales Short Circuit Current(Isc) 11.49 A 11.42 A 11.35 A 11.28 A 11.21 A ---------------------------------------------------------- ------------------- ----------------- ------------------ ------------------ ------------------- Module Efficienty Mounti 20.3% 20.0% 19.7% 19.5% 19.2% 8-1Mount155X0.35] ng slots Operating Module Temperature -40°C to+85°C Barcode --------------------------------------------------------------- ----------------------------------------------------------------------------------------------- Maximum System Voltage 1000 V DC(IEC) Section A-A ------ ------- ------- -------- --------- ----------------- (Rear View) Maximum Series Fuse Rating 20 A Ar IA PowerTolerance 0/+5 W m Junction box ±1 +1 STC:Irradiance 1000 W/m',module temperature 25°C,AM=1.5; m CO Tolerance of Pmax is within+/-3%. o6 n m 35[1.381 y rn NMOT ba STPXXXS-B60/Wnhb Section B-B Maximum Power at NMOT(Pmax) 278.2 W 274.3 W 270.7 W 266.8 W 263.3 W 7 Optimum- -Operating Voltage(Vmp) 32.0-V 31.8-V 31.6-V 31.5 V 31.3-V n Optimum Operating Current(Imp) 8.69 A 8.62 A 8.56 A 8 48 A 8.42 A Open Circuit Voltage(Voc) 38.7 V 38.5 V 38.4 V 38.2 V 38.0 V Short Circuit Current(Isc) 9.17 A 9.10 A 9.04 A 1 8.96 A 8.89 q Note:mm[inch] NMOT:Irradiance 800 W/m',ambient temperature 20°C,AM=1.5,wind speed 1 m/s. 111-Temperature Characteristics Nominal Module Operating Temperature(NT) 2 -------------------------------------------------------------------------------MO---------------- ------------------------42------±------°C--------------------------- Current-Voltage & Power-Voltage Curve (370S) Temperature Coefficient of Pmax -0.36%/oC 12 -400 ----------------------------------------------------------------------------------------------- --------------------------------------------------------------- Temperature Coefficient of Voc -0.304%/oC 10 350 Temperature Coefficient of Isc 0.050%/oC 300 a 250 a � C 6 200 y V a° 150 Mechanical Characteristics 100 Solar Cell Monocrystalline silicon 166 mm 2 50 No.of Cells 120(6 x 20) ----------------------------------------------------- ------------------------------------------------------------------------------------------------------- Dimensions 1756 x 1039 x 35 mm (69.1 x 40.9 x 1.4 inches) ° o 10 20 30 40 50° ----------------------------------------------------- -------------------------------------------------------------------------------------------------------- Weight 20.3 kgs (44.8 lbs.) Votage(V) ------------------------------------------------------ -------------------------------------------------------------------------------------------------------- Front Glass 3.2 mm (0.13 inches)tempered glass -,000wim=- 800wim=-e0°w/m=- 400w/m'-20owar,= Frame Anodized aluminium alloy Junction Box IP68 rated (3 bypass diodes) ------------------------------------------------------ -------------------------------------------------------------------------------------------------------- Output Cables 4.0 mm2, Portrait:(-)350 mm and (+)160 mm in length Landscape:(-)1300 mm and (+)1300 mm in length or customized length Connectors MC4 compatible Dealer information Packing Configuration Container 20'GP 40'HC Pieces per pallet 31 31 ------------------------------------------------------ --------------------------------------------------- --------------------------------------------------- Pallets per container 6 26 Pieces per container 186 806 Packaging box dimensions 1786 x 1130 x 1203 mm Packaging box weight 679 kg Information on how to install and operate this product is available in the installation instruction.All values indicated in this data sheet are subject to change without prior announcement.The specifications may vary slightly.All specifications are in accordance with standard EN 50380.Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. RT� MINI Self-flashing base for asphalt & metal roof-top PV mounting systems RT- MINI is suitable for mounting any rail system with a conventional L- Foot. - fir � P .A WW T�~ - I •.�J'4,T1� r.}. F f r+ f f. ' • Dual bolt design : M8 or 5/ 16" for L- Foot & 1 /4" for EMC /� •y 4''•r 4 Easy tapping 1/4" Hex Bolt screw guide upper channel 1CC Flat lip for M8 or 5/16" Hex Bolt M ICC ESR 3575 PV Cable clips bottom channel Installation Manual oo ec Smarter PV mounting solutions from • • of • • to bottom www.roof-tech.us • • • RT� MINI Flexible Flashing certified by the International Code Council (ICC) Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) Components Dimensions in (mm) RT2-00-M I N I B K C' 0 0 0 3 1/2 ( 90 ) 0 0 2 ( 50 ) 0 0 M ��ti MINI base : 20 ea. �- Screw : 40 ea. Rafter installation Qr6z Extra RT-Butyl : 10 ea. Optional item 5 x 60mm Mounting screw (RT2-04-SD5-60) : 100 ea./Bag 5/16" Hex bolt, washer & nut set (RT-04-BN30SL-US) : 100 ea./Bag RT-Butyl (RT2-04-BUTYLT) : 10 ea./Box RT-Butyl is Roof Tech s flexible flashing used in one million residential PV systems for the last 26 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. Engineered to withstand wind speeds up to 180 mph and `J ground snow up to 90 psf. Metal Flashing Retrofit Flexible Flashing or -} +` Deck installation 70 Shedding water? 100% Waterproof ICC ESR-3575 ASTM2140 testing UV testing (7500 hrs.) E. P.E. Stamped Letters available at www.roof-tech.us/support TAS 100 A on metal and asphalt roof. Roof Tech Inc. www.roof-tech.us • • • 858.935.6064 v.03-2020 1IOL11TA1125 open Energy For All u Microinvefter Description Datash _ _ Hoymiles 2-in-1 microinverter can connect up to 2 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. H M-600 N H M-7OON All of the three models listed are equipped with reactive power H M-8OON control and are compliant with IEEE 1547, UL 1741 and CA Rule21 . Features Easy installation,just plug and play External antenna for stronger communication with DTU � With Reactive Power Control, compliant with CA Rule 21 High reliability, NEMA 6 (IP67) enclosure, Compliant with U.S. NEC-2017&NEC-2020 6000 V surge protection 690.12 rapid shutdown Technical Specifications Model HM-60ON HM-70ON HM-80ON Input Data (DC) Commonly used module power(W) 240 to 405+ 280 to 470+ 320 to 540+ Maximum input voltage (V) 60 MPPT voltage range (V) 16-60 Start-up voltage (V) 22 Maximum input current(A) 2 X 11.5 2 X 11.5 2 X 12.5 Output Data (AC) Peak output power(VA) 600 700 800 Maximum continuous output power(VA) 590 696 766 Maximum continuous output current(A) 2.46 2.84 2.90 3.35 3.19 3.68 Nominal output voltage/range (V)' 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range(Hz)' 60/55-65 Power factor(adjustable) >0.99 default 0.8 leading...0.8 lagging Total harmonic distortion <3% Maximum units per branch 6 5 5 4 5 4 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range(°C) -40 to +65 Dimensions(W X H X D mm) 250 X 170 X 28 Weight(kg) 3 Enclosure rating Outdoor-NEMA 6(IP67) Cooling Natural convection - No fans Features Communication 2.4GHz Proprietary RF(Nordic) Monitoring S-Miles Cloud Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA(240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. ©2021 Hoymiles Power Electronics Inc.All rights reserved. 1IOL11TA1C25 Open Energy For All um��n MIME � a Microinverter Description Datasheet Hoymiles 4-in-1 microinverter is one of the most cost-effective module-level solar solutions, as it can support up to 4 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and H M-1200N NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. H M-150ON All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21 . Features Easy installation,just plug and play External antenna for stronger communication with DTU � With Reactive Power Control, compliant with CA Rule 21 High reliability, NEMA 6 (IP67) enclosure, 1 Compliant with U.S. NEC-2017&NEC-2020 6000 V surge protection 690.12 rapid shutdown Technical Specifications Model HM-120ON HM-150ON Input Data (DC) Commonly used module power(W) 240 to 405+ 300 to 505+ Maximum input voltage (V) 60 MPPT voltage range(V) 16-60 Start-up voltage(V) 22 Maximum input current(A) 4 X 11.5 4 X 11.5 Output Data (AC) Peak output power(VA) 1260 1200 1500 1350 Maximum continuous output power(VA) 1200 1109 1438 1246 Maximum continuous output current(A) 5 5.33 5.99 5.99 Nominal output voltage/range(V)' 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range(Hz)' 60/55-65 Power factor(adjustable) >0.99 default 0.8 leading...0.8 lagging Total harmonic distortion <3% Maximum units per branch 3 3 2 2 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range(°C) -40 to +65 Dimensions(W X H X D mm) 280 X 176 X 33 Weight(kg) 3.75 Enclosure rating Outdoor-NEMA 6(IP67) Cooling Natural convection - No fans Features Communication 2.4GHz Proprietary RF(Nordic) Monitoring S-Miles Cloud' Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA(240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. ©2021 Hoymiles Power Electronics Inc.All rights reserved. Sense Energy Monitor Technical Specifications Sense is a home energy monitoring device. It is used to measure current and voltage in the service mains and solar supply of your home. If installed outside, it must be kept dry and within specified temperature ranges. The Sense monitor should only be installed by a licensed electrician. Monitor (Monitor Model Nos. SM3, SM3S) Compatibility: 120VAC (90V-130V), 60 Hz Processor: 1 GHz ARM Wi-Fi: 2.4 GHz 802.11b/g/n Power Consumption: <5 watts, 0.1 amps Dimensions: 5 3/8" H x 2 5/8" W x 1 1/4" D y Weight: 220 g RH < 90%; Elevation < 3000 meters; Temperature: 0 - 500C Current Transformers CAT III, 300V, 200A max May be used on uninsulated conductors Dimensions: 3 6/16" H x 2" W x 12/16" D T Inside Diameter: 1" - � Cable length: 46" f Power Cable 16 AWG (UL), THHN or THWN, 600V. 44 Cable length: 14" Per UL requirements, the Sense energy monitor power cable itself is marked with all the required safety information, and compliance was verified as part of obtaining our safety certifications. It is jacketed with PVC to form a flexible power cord of UL type SVT, and marked as such. Certifications Certified to CSA STD C22.2 No. 61010-1 Conforms to UL STD 61010-1 Conforms to CAN ICES-3(B)/NMB-3(B) C T 0S'� US * sense I ntertek 5002148