Loading...
HomeMy WebLinkAboutPermit File bld 4507 Queen Ann WayResidential Building Air Leakage Test (Blower Door Test) Results 6,Permit #: /-( 1 L, Y House address or lot number: 4-J`0 7 Q oe-e-h A h Ljo City: A1 ii c,2r t ?-J Cond. Floor Area (ft2): 3o �� Zip: Age of house: 0 Source (circle one): la Estimated Measured Results shall be reported as Air Changes per Hour at 50 Pascals (ACH5o) and shall be calculated as follows: Where: ACH5o = (CFM50 x 60)/ Volume CFM50 = Blower door fan flow at 50 Pascal pressure difference Volume = Conditioned Floor Area of the housing unit x ceiling height Blower Door Test Result: !' ACH5o 6 ` --j CFM@50Pa Ring (circle one if applicable): Open 6 B C Blower Door Fan Location: F�, �^y /�oro f- Weather Conditions: C L vv �y I certify that these blower door results are accurate and determined using standard industry protocol. Company Name: I r CUIJ y1 f'{ e C - %, Technician: P ar✓ Technician Signature: ► Date: ` Z I I-?— Phone Number: 2012 Washington State Energy Code reference: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3 5 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed the presence of a gasket (see Section 502.4), operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. Permit #: 5,< c-I l le T Duct Leakage Affidavit (New Construction) House address or lot number: - D 7 Q v e e h 1Y, i_j :� y City: Zip: Cond. Floor Area ftz : 3 V 3 6 ( ) Source (circle one): &s Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? 21 yes 0 no Circle Test Method: Leakage to Outside Air Handler present during test? 0 yes 0 no 6al Lea ge Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) _ L CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .04) _ Rough -In, total duct leakage with air handler not installed: (floor area x .03) _ Test Result: i bo CFM@25Pa Ring (circle one if applicable): Open Duct Tester Location: �v%+1 y et_ CFM@25 Pa 2 3 CFM@25 Pa Pressure Tap Location: R a �u � &I d r I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: _17 h c� �� jlz p t � V, y Technician: P $, ✓ Technician Signature: Date: 6-2- It' _ Z 1- Phone Number: Lf Z_g - 0 9 1 � GENERAL PLUS INSULATION, LLC &z GUTTERS 10614 COLLINS ROAD SEDRO-WOOLLEY, WA 98284 PH: 360-630-6341 EM: GPIinsulation@hotmail.com Bill To BURMASTER HOMES Job Site 4705 QUEEN ANN WAY ANACORTES, WA P.O. No. I JOB # 6657 Description COMPLETED INSTALLATION PER ESTIMATE 2" R14 CLOSE CELL SPRAY FOAM AT FLAT CEILING HOUSE. R38 OF BATTS AT FLAT CEILING AREA UNDER SPRAYED FOAM. RI 1 OF BATTS TO WRAP HOT WATER PIPES AT HOUSE. R21 OF BATTS AT EXTERIOR WALLS. R21 FSK BATTS AT BAND JOINS. R9.9 1.5" RIGIT BOARD AT EXTERIOR WINDOW HEADERS. R38 OF BATTS AT CRAWL SPACE, SECURED WITH TWINE. RI I OF BATTS TO WRAP WATER PIPES AT CRAWL SPACE AREA. 6MIL BLACK POLY FOR GROUND COVER AT CRAWL SPACE AREA. R38 OF BATTS AT BASEMENT CEILING UNHEATED AREA. AIR SEAL TO WA STATE ENERGY CODE. OPTIONS: RI 1 OF BATTS AROUND MASTER BEDROOM TO LIVING ROOM, BASEMENT BATH, POWDER ROOM AND LOUNDRY FOR SOUND. 2" CLOSE CELL SPARY FOAM AT GARAGE CEILING WITH R19 BATTS UNDER AND R19 AT EXTERIOR WALLS. RI 1 OF BATTS AT 2X4 STORAGE AND FURNACE EXTERIOR WALLS. R19 OF BATTS AT STORAGE EXTERIOR WALLS. RI 1 OF BATTS IN BETWEEN FLOORS. Thank you for your business. Subtotal Invoice Date Invoice # 3/16/2022 8819 Terms Rep Due on receipt EN Amount 15,400.00T Sales Tax (8.8%) Payments/Credits 432.00T 3,790.00T 250.00T 350.00T 450.00T $20,672.00 $1,819.14 $0.00 Balance Due $22,491.14