Loading...
HomeMy WebLinkAboutPermit File BLD-2022-0835 3505 Malland Court 1 C} City of Anacortes Invoice/Permit M BLD-2022-0835 904 6th Street Applied date: 10/24/2022 P.O.Box 547 Issue date: 10/25/2022 _, Anacortes, WA 98221-0547 Expire date: 04/22/2024 (360) 293-1901 Job Address: 3505 MALLAND CT Permit Type: Single Family Interior Only Alteration Permit ANACORTES WA98221-3691 Project: APN: P118706 Remarks: Replace existing deck and add additional support. Owner: BRIAN & BARBARA FENDLY& MOTTICE Contractor: ISLAND DECK AND RAIL LLC Address: 3505 MALLAND CT Address: 4017 W 6TH ST ANACORTES WA98221-3691 ANACORTES WA98221-1275 Phone: (541)255-9313 Phone: (360)391-8262 License M General Information: Fees: Deck Square Footage 80 Building Permit Fee 209.25 Building Valuation 12000 Plan Review Fee 136.01 State Building Code Fee Resi 6.50 Total Calculated: 351.76 Deposits/Receipts: 0.00 Total Due: 351.76 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY & ( k _ \ k 2 \ \ C - z E z - \ % 0 - w \ / / \ « § w J ) ( } \ \ £ d \ } § / § X \ 2 r E / 9 F- � \ i D @ 0 \E z \ { \ / OD ± 2 m m = \ \CL I \ / ) •2 ® - _ j \ tw - f .. k < 0 Wp&. �; �o §■ ± / v CD \j \ § f \ \\ a) z ai . \ } \c \ ` \�S o I \ \r\ \ _\\ / \\z � J % « ^ C E m E k / \ < 0 c = a U \ \ § / / § _ � « § = k i 4 0 k $ \ \ \ § 2 \ _ o = Q » \ ƒ Cl) = - $ 2 / ƒ 2 E - = o @ e / / J / § e k < / / } ¥ § r 7 j Cl) k < 2 = z E { = CD ƒ @ - [ \ ? ƒ < e 0') t \ 1 / Q o % a ƒ O < _ _ n k k § / \ \ * - \ 2 Q 2 } § ® / \ \ - \ -FD \ \ E _ tw - \ - % 0 _ § r 2 \ r J \ \ E d o « @ z = 2 _ E _ % G / k \ IL W < l \ < � � ) - \ - - \ 3 \ { E \ GAT Y O.n AVRWW PLANNING,COMMUNITY,& ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 ; 9 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360)293-1901 RESIDENTIAL BUILDING PERMIT APPLICATION THIS APPLICATION PACKET IS USED FOR THE FOLLOWING PROJECT TYPES: Single-Family Residences (SFR), Duplexes, Additions & Remodels, Accessory Structures (i.e. garages, carports), Accessory Dwelling Units, Manufactured Homes, Residential Decks & Retaining Walls, and Docks& Pilings. FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY INFORMATION PROJECT ADDRESS(STREET,SUITE#) ASSESSOR PARCEL NUMBER 3505 Malland Court 118706 SUBDIVISION/LOT# ZONING LOT AREA(SIZE) 8971 Malland Meadows, Lot 1 R3 s4. FT. TYPE OF PROJECT NEW ADDITION Lj REPAIR X REMODEL CHANGE OF USE SFR Duplex N Deck/Porch Accessory Dwelling Unit: Detached ❑Attached Retaining Wall ❑Manufactured Home ❑Accessory Structure ❑ Shoreline Structure(dock,pilings,floats etc.) * ❑Other: *If application is for a shoreline structure,please complete the Shoreline Structure Checklist. IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? HYES ,( NO If YES,provide the permit/application number: PROJECT SUMMARY: PROJECT VALUATION Replace existing deck. Add additional support & bracing. (Cost of Materials&Labor) Replace composite decking, replace wood rails/caprails with $12,000 powder-coated aluminum and SS cable wiring. PROPERTY OWNER INFORMATION NAME PHONE Fendly-Mottice 1996 Trust 541-255-9194 (Barbara) 541-255-9313 (Brian) ADDRESS(STREET,CITY,STATE,ZIP) EMAIL ADDRESS 3505 Malland CT,Anacortes, WA 98221 mvpassage@gmail.com CONTRACTOR INFORMATION NAME* PHONE Dylan Halverson 360-391-8262 CONTRACTOR'S BUSINESS LICENSES STATE LICENSE# EXPIRATION *All Contractors&Subcontractors must have a valid City ISLANDR792LD 06/04/2023 of Anacortes business license prior to doing work in the UBI# EXPIRATION City. 604-744-442 06/04/2023 ADDRESS(STREET,CITY,STATE,ZIP) EMAIL ADDRESS 4017 W 6th St Anacortes, WA 98221 islanddeckandrail@gmail.com Page 1 of 17 Res.Building Permit Application Submittal Checklist Updated April 20,2021 CONTACT PERSON-Select one person the city will contact for anything related to this project: ❑■ APPLICANT gPROPERTY OWNER ❑CONTRACTOR ❑OTHER(LIST BELOW) NAME PHONE Barbara Mottice 541-255-9194 ADDRESS(STREET,CITY,STATE,ZIP) EMAIL ADDRESS 3505 Malland CT Anacortes, WA 98221 mvpassage@gmail.com LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lender involved with your project, write "no lenders"on the Name Line below. NAME PHONE No Lenders ADDRESS(STREET,CITY,STATE,ZIP) EMAIL ADDRESS ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technical!y complete and su icient for staff review. I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. I understand and acknowledge that I could be responsible for providing as-built drawings(on paper D+� or electronicall as part of the ro'ect's certificate of occupancy process. I understand and acknowledge that Special Inspections could be required as part of my project, and if needed i will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. I understand that if permits are reviewed concurrently such as design review,site plan, traffic concurrenty, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. SIGNATURE DATE Barbara A Mottice PRINTED NAME Res.Building Permit Application Submittal Checklist Updated December 2021 Page 2 of 17 �r ,aT I -- Y i _ p �e k gym ' r 3505 Malland Court Q F C P � Anacortes, WA 98221 �� K �) Parcel #118706 "eo_ 3505 Malland Court Anacortes, WA 98221 D ��K Parcel #118706 �t i r d y �.. ! �Y FORM BP-2: STRUCTURE AND SITE INFORMATION PROPERTY WHERE WORK IS OCCURRING ADDRESS 3505 Malland Court, Anacortes, WA 98221 PARCEL NUMBERS) 118706 DETAILED PROPOSED STRUCTURE INFORMATION Complete the following information as it relates to your project. Mark items that are not applicable with "N/A". STRUCTURE HEIGHT 45 inches AREA SQUARE FOOTAGE OCCUPANCY GROUP CONSTRUCTION TYPE OCCUPANT LOAD 1sT FLOOR: N/A 2ND FLOOR: N/A 3RD FLOOR: N/A BASEMENT: N/A GARAGE: N/A TOTAL DECK: 80 sf -- -- -- TOTAL PORCH: N/A OTHER: N/A OTHER: N/A OTHER: N/A QUESTIONS ABOUT THE PROPOSED STRUCTURE Is a fire sprinkler system being installed? YES ONO Is a monitored fire alarm being installed? LJYES ®NO Are retaining wall(s) being built? ❑YES ENO Are structural plans required? I YES LJNO PROJECT SITE INFORMATION A. Is work within the City's right-of-way proposed? ❑YES ONO If YES,you will be required to submit a right-of-way permit application. If you have already submitted a ROW permit, list the permit number here: B. Is the lot less than 5,000 sq.ft. in area? AYES ONO If YES,your site and building will need to comply with the standards in AMC 19.43.010.C. Res.Building Permit Application Submittal Checklist Updated December 2021 Page 6 of 17 C. Is your project involving an accessory dwelling unit? YES ZNO If YES,your site and building will need to comply with the standards in AMC 19.47.030. D. Will more than 2-acres be cleared and/or more than 5,000 board feet OYES NNO (about 1 log truck load)of timber be harvested? If YES,you may need to obtain a forest practice permit from DNR. E. Is this project subject to the SEPA process? DYES X NO If YES,you will be required to submit a SEPA checklist. If you have already completed the SEPA process, list the permit number: REQUIRED SIGNATURE 1 hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. 1 also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application farm is in all respects, true, correct, and complete to the best of knowledge and belief. SIGNATURE DATE Barbara A Mottice PRINTED NAME Res.Building Permit Application Submittal Checklist Updated December 2021 Page 7 of 17 FORM BP-6: SITE PLAN REQUIREMENTS GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant site plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11"x 17" and drawn in an engineering or architectural scale. INFORMATION REQUIRED ON ALL SITE PLANS COMPLETE? L �REQUIREMENTS PAGE# ON PLANS COVER SHEET: x Vicinity Map '�p b 10 ) Name of the project Name, address, and telephone number of owner and agent(s) 4)lL Name, address, and telephone number of Applicant (if different from the owner) Zoning designation of the site Area, in square feet and acreage,of the project site Reference to the Building Code used 0 Proposed use N 1 I2" Occupancy group tQ1 Construction type Square footage and height of each individual building N I (� Percent lot coverage - , 1-1 °lo Percent impervious surfaces Scale and North Arrow Property features Location, identification, and dimensions of all property lines and easements. All easements shown on the title report, Record of Survey, or plat must be dimensioned and shown. Location and dimensions of existing critical areas (wetlands, streams, steep slopes)and their associated buffers. Location of Ordinary High Water Mark and shoreline jurisdiction limits (i adjacent to a shoreline). Existing and proposed contours and site elevations(i.e. finished grades) at 5 foot minimum increments. The horizontal and vertical control datum must b clearly shown. Structures �. Location, identification, dimensions and size of all existing and proposed buildings and other structures. Res.Building Permit Application Submittal Checklist Updated December 2021 Page 15 of 17 Location of existing and proposed retaining walls, rockeries, and fences. Q , 6 \_ Location, identification, and dimensions of all setbacks. Show proposed projections into required setbacks, including dimensions(see AMC 19.44.140) Utilities & Easements Location and dimensions of existing and proposed stormwater,sanitary sewer, potable water, and fiber lines/facilities. All wells and septic systems located on or near the project site must also be identified. Location of all existing and proposed fire hydrants within 300 feet of the boundary of the project site. Location and dimensions of existing and proposed freestanding lighting fixtures, utility junction boxes, public utility transformers. stormwater Proposed Temporary Erosion and Sediment Control Measures, if not located on other plans. Proposed permanent stormwater management BMPs. Access, Circulation & Parking Location, identification, and dimensions of all existing and proposed on-site and adjacent streets and alleys, including the location and dimensions of all existing and proposed curbs,gutters, sidewalks, median islands, and street trees. ` Show existing and proposed vehicular access to the site, including the size and location of driveways and curb cuts. Show existing and proposed parking spaces, including surface material and dimensions of spaces. Open Space(ADUs,Small Lots, and Duplexes) Show calculations, location, dimensions and provided square footage of required open space area per AMC 19.43.010.C, E, or AMC 19.47, as applicable. Landscaping Show the location and design of landscape areas to be preserved and planted, and a plant list to include the location, number, size and type of plant material by botanical and common name. Location of irrigation system if a permanent or temporary system is proposed. Show the location of existing trees to be retained in conformance with AMC 16.50, and tree protection measures to be implemented,when applicable. Provide a maintenance plan for any infiltration-based stormwater best management practices(BMPs) built as part of the landscaping design, including the specifications and maintenance procedures of any soil amendments. Show new trees to be planted and tree unit credit calculations, in conformance with AMC 16.50 Tree preservation,when applicable Res.Building Permit Application Submittal Checklist Updated December 2021 Page 16 of 17 �� ( P\ A table similar to the following with project specific information provided, must be placed on the site plan: Required Landscaping For Example Calculations Site Area 7,500 s .ft. %of site area to be landscaped(per 20%- R2A zone AMC Tables 19.42.020-.030) 1,500 sq.ft. required 1,850 s .ft. provided Compliance with AMC Ch. 16.50 Tree unit credits required: Tree Preservation. • 8 tree units required Tree unit credits retained: • 2 trees 6"dbh=4 tree unit credits retained Tree unit credits provided: • 2 new deciduous trees(min. 2" caliper @ 6"above ground) • 2 new evergreen trees(8'in height) Number of required street trees 1 per 30'of frontage 60 lineal feet of frontage=3 street trees Res.Building Permit Application Submittal Checklist Updated December 2021 Page 17 of 17 -operty Search LRLP5.11JAQ�1RVUUL�.uVu�liUwua.vYv �, .... ANACORTES,WA 98221 Property map CA L 35CS KALLAND C7 + I",\U,.iK o-L &-k-(--- 51��r� -. i CIE 0 .a 1 cti c t-eS 3TT -s7KCET �- 5z4I as5 - 130 d 0 4 Center Property Open in iMap Directions Top Back Home Privacy&Terms of Use ©2021 Skagit County ?-oft-- 10/19/2022,3:12 PM C N o LU Z 1� "w' V `) Z� r U v I 191 `n^04 M v J - i YI i W 4 a a C O V � o G) m I c U U U U U C C C C U C C C C co in b� io v rnI m 'v 'v 'a io 'n M � rnO Oco uO� g O aOAo I o(0O�1 rMOI 79 N O OtC O I O O O O O O C14 cm N NI - N N N N N N N N N J W U d H Q J J SG U c� cw Q �4- + o� v + e + -a L4, 0) '< S1 U 6LU In N ;xe xew ww V/ C I r M Q-C W a =e g a Lu 5 � � W � r - _ � Q M 0 0- 0 1 L - Iv M fi Via Q � LL Z t ` .Z c,- � � C Q'Imin -� o V W Z LJJ (7 Q S F- Z CAa U o N �Z) '^ a� ° 0 J a om Z o V a uOOLLJO a c t- o Z m wONQ aj o- � E c i� � Q 0 > UO � 00 > cU - Z0o0 � � W� ,� a o 0 LA a v `�` Z Q 2�m co Lu '• � r LY J > '* Ln > La wow w cc � Q � om b ~ Q w U d a Q Q w m V Z) V) Vi o� t cA 0 pi C: sQZ a o -0 � m • .• N a t Z ` t J � d n '` E y A Z rn N m y U c cy{ U c a m O 0 7 c m T Z 0 _ 4 0 Y Z f ^ v � 4 BI9B188S N M � IL 3505 Malland Court Anacortes, WA 98221 Parcel 4118706 LA R-��� F N 1b `l c A_ f ti �•'��.w' - Lei i, .p - v . "ate G' 1 K �� .. •:. _.._ �x t i My6ui ldi ngPermit.com a service of eCrtyGov.net Construction Tip Sheet 02 Residential Handrails This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. Where Required Handrails are required on at least one side of each continuous run of treads or flight with four or more risers. Typical Details Handrails are continuous for the Full length or the flight. Handrails may be interrupted { by a newel post at a turn. Haridrads are required on not lairs than one side of each Handrail ends retume continuous run of to The wall or terminated treads or ftt in newel posts or safety , with four or more terminals. risers_ I r The height or the handraif is measured vertically from the sloped plane adjoining the tread nosing. Figure 1: Typical Handrail Elevation (IRC R311.7.8) The hared4l may e i a maximum of 4-1! 'm1a reau ired stair width. The grippable 1-112"minimum perimeterdimension is 4'rninkmum and 6-114" 9z maximum, Circular handrails not less than 1-114' or more than 2" in diameter. The non-6rcular handrail cross section is 2-114"maximum_ Figure 2: Type I Handrails (IRC R311.7.8.5) January 22, 2021 MyBuilding Permit.com I Residential Handrails 1 ecityGay.net M,:eCllyGow llianm My6ui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 02 1-1/4" minimum - 2-3/4" maximum Sand smooth, no sharp cornefs 1-314" 3/4" maximum minimum 5116" minimum 1-112" minimum Figure 3: Type II Handrails (At handrails with a perimeter greater than 6-1/4 inches) (IRC R311.7.8.5) Figure 4: Unacceptable Handrails January 22, 2021 MyBuildingPermit.com I Residential Handrails 2 eCityGwnet 2M,I:eGILVGovdllianca My6ui ldi ngPermit.com a service of eCrtyGov.net Construction Tip Sheet 03 Residential Guards (Guardrails) This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. Open stair handrail Open guard Solid guard See handrail Tip Sheet#2 for applicable handrail information. The top of gkxards for slWrwap,excliusive Of i Moir landings,rnU% have a minimum height of 34'measured ,c veWcally korn the 12D nosing of the treed_ e� A OPEN RAILING TYKES � A, A sphere 6"In 4iarneter cannot , pass through � B: A sphere 4"In diameter cannot M Ly pass through 6 no k- Grade or floor level C- A sphere 4-18"in d iamarer EUL i cannot pass through I Figure 1: Guard Elevation (IRC R312) Requirements ❑ Guards shall comply with IRC R312.1; refer to Figure 1 for major requirements. ❑ Guards shall be structurally designed to comply with IRC Table R301 .5 (i.e., designed for a 200-pound load in any direction along the top and a 50-pound point load elsewhere). ❑ For glass guards or guards with glazing, see IRC R308.4.4. January 22, 2021 MyBuilding Permit.com I Residential Handrails 1 ecityGov.net M,1:eCllyGow llianm