Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0758 4515 Blakely Drive (3)PHOTOVOLTAIC ROOF MOUNT SYSTEM 16 MODULES - SYSTEM SIZE STC (5.44 kW DC / 3.84 kW AC) 4515 BLAKELY DR, ANACORTES, WA 98221, USA (48.49613)-122.66627) SYSTEM SUMMARY STC DC/AC (5.44 kW DC / 3.84 kW AC) • 2x STRINGS OF 8 CONNECTED IN PARALLEL - (16) Hanwha Q.Peak Duo-G6 340 MODULES - (16) Enphase IQ7-60-2-US MICROINVERTERS STC DC: (16) 340 = 5.44 kW STC AC: (16) 240 = 3.84 kW GOVERNING CODES 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL RESIDENTIAL CODE GENERAL NOTES: • ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. • THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. • ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE LISTED BY .'UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. • WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN CONCEALED SPACES (UNLESS APPROVED OTHERWISE) AND SCHEDULE- 40 PVC FOR BELOW GROUND INSTALLATION UNLESS NOTED OTHERWISE. • AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION. • IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF NECESSARY. SAFETY PLANS NOTES: • INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. • INSTALLERS SHALL UPDATE NAME, ADDRESS AND PHONE NUMBER OF NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK. PROPERTY Lit LOCATION OF NEAREST URGENT CARE FACILITY NAME: ADDRESS: CITY OF ANACORTES PHONE NUMBER: PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT #: BLD-2020-0758 ADDRESS: 4515 Blakely DR APPROVED BY: SUBJECT TO FIELD INSPECTION. APPROVED PL S SHALL NOT BE ALTERED WITHOUT AUTHORIZA ON. / —lc_ O MSP MAIN SERVICE PANEL qG` AC DISCONNECT UNFUSED I NV (0) INVERTER gqg SUB -PANEL EEEX ST EQU PIING MENT ROOF ATTACHMENT - — — - PROPERTY LINE r NEW (200A) NEW N/A N/A m U M UTILITY METER ACF AC DISCONNECT FUSED LOAD CENTER LC (COMBINER PANEL) NEW DCD DC DISCONNECT N/A ■ OPTIMIZER — —DIMENSIONS FENCE m NEW N/A 7 PM PRODUCTION METER Jg JUNCTION BOX SM SOLAREDGE METER ECIC DC COMBINER N/A MICRO -INVERTER PV MODULE � GATE N/A NEW N/A I gqT BATTERY I qT AUTO TRANSFORMER gLp BACKUP LOAD PAN N/A N/A N/A SITE PLAN & SAFETY PLAN SCALE: 1/16" = V-0" SHEET INDEX PV-1 SITE PLAN & SAFETY PLAN ' • PV-2 ROOF PLAN WITH MODULES ' PV-3 ATTACHMENT DETAIL • ' • PV-4 SINGLE LINE DIAGRAM PV-5 THREE LINE DIAGRAM CONTRACTOR PV-6 WIRING CALCULATION PV-7 PLACARDS NAME: N/A PV-8+ EQUIPMENT SPECIFICATION ADDRESS: N/A PHONE#:N/A LICENSE #: N/A PROJECT ID: N/A AHJ: SKAGIT ARRAY LOCATION N� 3 HOUSE PHOTO SCALE: NTS PROJECT SITE 4515 Blakely ❑rive VICINITY MAP SCALE: NTS REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME VJ D z N O �00 0� Lu Q W Q L1J m Lu Lo I— LL,I � cy �O z Q SHEET NAME SITE PLAN & SAFETY PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 MODULE AREA & WEIGHT CALCULATIONS PANEL TYPES (COUNT, AREA, WEIGHT): • (16x) Hanwha Q.Peak Duo-G6 340 (68.5" x 40.55", 43.9 LBS) ATTACHMENT COUNT: 45 MOUNTING SYSTEM WEIGHT/MODULE: 1.5 LBS TOTAL ROOF AREA: 1992 SF TOTAL ARRAY AREA: (16) 68.5" x 40.6" = 308.63 SF TOTAL ARRAY WEIGHT: (16) 43.9 + (16) 1.5 = 726 LBS WEIGHT AT EACH CONNECTION: 726 LBS / 45 = 16.14 LBS DISTRIBUTED LOAD: 726 LBS / 308.63 SF = 2.35 PSF ROOF AREA COVERED BY ARRAY: 309 SF / 1992 SF = 15.5% BILL OF MATERIALS SOLAR PV MODULES 16 Hanwha Q.Peak Duo-G6 340 MICRO INVERTERS 16 Enphase IQ7-60-2-US LOAD CENTER 01 AC COMBINER PANEL (MIN RATING 20A) AC DISCONNECT 01 PV VISIBLE LOCKABLE LABELED DISCONNECT (30A UNFUSED 1PH 240VAC) ATTACHMENTS 45 IronRidge - FIashFoot2 RAIL IronRidge - XR10 ROOF DESCRIPTION ROOF ARRAY TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING (ATTACHMENT SPACING) #1 20' 100, 2"X4" 12" o.c. (48") #2 20° 280' 2"X4" 12" o.c. (48") M S P MAIN SERVICE PANEL qC AC DISCONNECT UNFUSED I N V (0) INVERTER SUB -PANEL 9�q NEW (200A) NEW N/A N/A E-7 UTILITY METER ACF AC DISCONNECT FUSED LC LOAD CENTER (COMBINER PANEL) NEW DCD DC DISCONNECT N/A NEW N/A ��] PRODUCTION METER J g JUNCTION BOX SM SOLAREDGE METER DG'G' DC COMBINER N/A N/A NEW N/A gqT BATTERY qT AUTO TRANSFORMER gip BACKUP LOAD PANEL N/A N/A N/A ROOF PLAN WITH MODULES SCALE. 1 /8 = 1 0 EE EXISTING EQUIPMENT ■ OPTIMIZER MICRO -INVERTER 1r_2„ • ROOF ATTACHMENT — // —DIMENSIONS PV MODULE M 0) LL O O cc RAFTERS r m ROOF RAILS m z p—� f FIRE SETBACK N CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A LICENSE #: N/A REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME Q U) N 0 _j00 d') W Q m Q w m W Lo F-- w � �0 Q z Q SHEET NAME ROOF PLAN WITH MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 ATTACHMENT DETAIL SCALE: NTS SEI EN I. IRONRIDGE INTEG GROUNDING & El ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT IRONRIDGE FLASI FOOT2 ATTACHMENT; 2 ATTACHMENT DETAIL (ENLARGED SECT SCALE: NTS CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A R O F LICENSE #: N/A NGLE REVISIONS DESCRIPTION DATE V MODULES IRONRIDGE XR10 RAIL (E) SINGLE LAYER OF COMPOSITE SHINGLE FLASHING 6"x3.5" SS LAG BOLT TH MIN 2%2" THREAD IBEDMENT, SEALED NETRATION \AFTERS SIGNATURE & SEAL PROJECT NAME Q U) z � 0 N O >- co W Q m Q w J U) co Lu L w � O Q z Q SHEET NAME ATTACHMENT DETAIL SFitt I SILL ■ ANSI B 11" X 17" SHEET NUMBER PV-3 SYSTEM SUMMARY STC MAC (5.44 kW DC / 3.84 kW AC) • 2x STRINGS OF 8 CONNECTED IN PARALLEL - (16) Hanwha Q.Peak Duo-G6 340 MODULES - (16) Enphase IQ7-60-2-US MICROINVERTERS STC DC: (16) 340 = 5.44 kW STC AC: (16) 240 = 3.84 kW MOD: Hanwha Q.Peak Duo-G6 340 INV: Enphase IQ7-60-2-US (240V) (1 STRING X 8 MICRO-INV) 71i • M S-01 MOD: Hanwha Q.Peak Duo-G6 340 INV: Enphase IQ7-60-2-US (240V) (1 STRING X 8 MICRO-INV) M S-01 JUNCTION BOX 600V, NEMA 3R UL LISTED M C B-01 M C B-01 ELECTRICAL SINGLE LINE DIAGRAM SCALE: NTS AC COMBINER PANEL WITH ENPHASE ENVOY XAM1-120 (OR EQUIV) 10A E�-, I LC-01 15A 15A NOTE: • ALL GROUNDING TO COMPLY WITH NEC 690.47. • ROOF TOP CONDUIT SHALL BE LOCATED MIN. 7/8" ABOVE ROOF SURFACE. • ALL TERMINALS SHALL BE MIN. 90 DEG. C RATED. PV VISIBLE LOCKABLE LABELED DISCONNECT (30A UNFUSED 1PH 240VAC) LC-01 NOTE: GROUNDING ELECTRODE CONDUCTOR/SYSTEM BONDING JUMPER NOT REQUIRED FOR SOLAREDGE POWER OPTIMIZER. PROPERLY INSTALLED SYSTEM MEETS THE REQUIREMENTS OF NEC 690.35 FOR UNGROUNDED PV POWER SYSTEMS. PROVIDE EQUIPMENT GROUNDING PER MANUFACTURER'S REQUIREMENTS IN COMPLIANCE WITH THE NEC. MAIN SERVICE PANEL (NEW, TOP -FED) BUS RATING: 200A MAIN BREAKER: 200A (N) 20A UTILITY METER UTILITY: PSE SERVICE: 240V 60HZ 1 PH 4 TO M UTILITY GRID CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A LICENSE #: N/A REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME Q 07 z � N 0 _00 O� LU Q m Q w CO L LJ Lo F-- w � � OU AC wire details Wire Min Ampacity Live Neutral Ground PVC Min RMC ���/� vJ Q MS-01 10.00A (2) 10 AWG PV 10 AWG PV 16 AWG THWN-20.75 MEMTin in 0.75 in z MCB-01 10.00A (2)10AWGTHWN-2 10AWGTHWN-2 10 AWG THWN-20.50 in 0.50 in Q LC-01 20.00A (2)10AWGTHWN-2 10AWGTHWN-2 10 AWG THWN-20.50 in 0.50 in INTERCONNECTION 120% RULE (MAIN PANEL) UTILITY FEED + TOTAL BACKFEED 200A + 20A = 220A LESS OR EQUAL TO BUS RATING X 120% 200A x 120% = 240A CALCULATION ENSURES BUS IS SAFE REGARDLESS OF LOADS EXTREME CASE MODULE OUTPUT Hanwha Q.Peak Duo-G6 340 Isc(25°C) = 10.68A, Tisc = 0.040%/°C Isc(T) = Isc(25°C) x [1 + Tisc x (T-25°C)] Isc(0°C) = 10.57A, Isc(40°C) = 10.74A Voc(25°C) = 40.24V, Tvoc =-0.280%/°C Voc(T) = Voc(25°C) x [1 + Tvoc x (T-25°C)] VOC(0°C) = 43.06V, Voc(40°C) = 38.55V SHEET NAME SINGLE LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 SYSTEM SUMMARY STC MAC (5.44 kW DC / 3.84 kW AC) • 2x STRINGS OF 8 CONNECTED IN PARALLEL - (16) Hanwha Q.Peak Duo-G6 340 MODULES - (16) Enphase IQ7-60-2-US MICROINVERTERS STC DC: (16) 340 = 5.44 kW STC AC: (16) 240 = 3.84 kW MOD: Hanwha Q.Peak Duo-G6 340 INV: Enphase IQ7-60-2-US (240V) (1 STRING X 8 MICRO-INV) ml� m M S-01 MOD: Hanwha Q.Peak Duo-G6 340 INV: Enphase IQ7-60-2-US (240V) (1 STRING X 8 MICRO-INV) 1 II 2 1 0 01 8 MS-01 III JUNCTION BOX 600V, NEMA 3R UL LISTED MCB-01 ELECTRICAL THREE LINE DIAGRAM SCALE: NTS AC COMBINER PANEL WITH ENPHASE ENVOY XAM1-120 (OR EQUIV) 10A LC-01 EE 15A NOTE: • ALL GROUNDING TO COMPLY WITH NEC 690.47. • ROOF TOP CONDUIT SHALL BE LOCATED MIN. 7/8" ABOVE ROOF SURFACE. • ALL TERMINALS SHALL BE MIN. 90 DEG. C RATED. PV VISIBLE LOCKABLE LABELED DISCONNECT (30A UNFUSED 1 PH 240VAC) LC-01 NOTE: GROUNDING ELECTRODE CONDUCTOR/SYSTEM BONDING JUMPER NOT REQUIRED FOR SOLAREDGE POWER OPTIMIZER. PROPERLY INSTALLED SYSTEM MEETS THE REQUIREMENTS OF NEC 690.35 FOR UNGROUNDED PV POWER SYSTEMS. PROVIDE EQUIPMENT GROUNDING PER MANUFACTURER'S REQUIREMENTS IN COMPLIANCE WITH THE NEC. MAIN SERVICE PANEL (NEW, TOP -FED) BUS RATING: 200A MAIN BREAKER: 200A (N) UTILITY METER UTILITY: PSE SERVICE: 240V 60HZ 1 PH TO M UTILITY GRID CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A LICENSE #: N/A REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME Q U) N O _00 d� LU Q m Q w CO L LJ Lo F-- w � AC wire details � OU Wire Min Ampacity Live Neutral Ground Min EMT Min PVC Min RMC vJ MS-01 10.00A (2) 10 AWG PV 10 AWG PV 10 AWG THWN-2 0.75 in 0.75 in 0.75 in z MCB-01 10.00A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in Q LC-01 20.00A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in INTERCONNECTION 120% RULE (MAIN PANEL) UTILITY FEED + TOTAL BACKFEED 200A + 20A = 220A LESS OR EQUAL TO BUS RATING X 120% 200A x 120% = 240A CALCULATION ENSURES BUS IS SAFE REGARDLESS OF LOADS EXTREME CASE MODULE OUTPUT Hanwha Q.Peak Duo-G6 340 Isc(25°C) = 10.68A, Tisc = 0.040%/°C Isc(T) = Isc(25°C) x [1 + Tisc x (T-25°C)] Isc(0°C) = 10.57A, Isc(40°C) = 10.74A Voc(25°C) = 40.24V, Tvoc =-0.280%/°C Voc(T) = Voc(25°C) x [1 + Tvoc x (T-25°C)] VOC(O°C) = 43.06V, Voc(40°C) = 38.55V SHEET NAME THREE LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 SYSTEM SUMMARY STC DC/AC (5.44 kW DC / 3.84 kW AC) • 2x STRINGS OF 8 CONNECTED IN PARALLEL - (16) Hanwha Q.Peak Duo-G6 340 MODULES - (16) Enphase IQ7-60-2-US MICROINVERTERS STC DC: (16) 340 = 5.44 kW STC AC: (16) 240 = 3.84 kW AC wire details WirelD #Modules Nominal Voltage Backfeed *1.25 /cond. set Min OCPD Total Power Conductor sets ccConductors /conduit Expected max temp Temp derate Conduit fill derate Conductor & neutral size EGC size (Cu) Conductor metal Insulation Max length V drop Min EMT size Min PVC size Min RMC size MS-01 8 240 V 10.00 A 15 A 1.9 kW 1 2 40 0.91 1.00 10 AWG 10 AWG Cu PV 50 ft 0.35 % 0.75 in 0.75 in 0.75 in MCB-01 8 240 V 10.00 A 15 A 1.9 kW 1 2 40 0.91 1.00 10 AWG 10 AWG Cu THWN-2 50 ft 0.35 % 0.50 in 0.50 in 0.50 in LC-01 16 240 V 20.00 A 20 A 3.8 kW 1 2 40 0.91 1.00 10 AWG 10 AWG Cu THWN-2 10 ft 0.14 % 0.50 in 0.50 in 0.50 in INTERCONNECTION 120% RULE (MAIN PANEL) UTILITY FEED + TOTAL BACKFEED 200A + 20A = 220A LESS OR EQUAL TO BUS RATING X 120% 200A x 120% = 240A CALCULATION ENSURES BUS IS SAFE REGARDLESS OF LOADS ELECTRICAL NOTES 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. L9GBL-4DBT MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO LAY -IN LUG. ) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. ) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. ) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). EXTREME CASE MODULE OUTPUT Hanwha Q.Peak Duo-G6 340 Isc(25°C) = 10.68A, Tisc = 0.040%/°C Isc(T) = Isc(25°C) x [1 + Tisc x (T-25°C)] Isc(0°C) = 10.57A, Isc(40°C) = 10.74A Voc(25°C) = 40.24V, Tvoc =-0.280%/°C Voc(T) = Voc(25°C) x [1 + Tvoc x (T-25°C)] VOC(O°C) = 43.06V. Voc(40°C) = 38.55V CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A LICENSE #: N/A REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME LU m Q W J m LL] V-- yj SHEET NAME Q U) N N 00 M U7 0 Q Z Q WIRING CALCULATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 LABEL LOCATION: BACKFED BREAKER CODE REF: NEC 705.2(4) LDO WARNING TER OUTPUT CONNECTI NOT RELOCATE THI ERCURRENT DEVIC FAI LABEL LOCATION. BACKFED BREAKER CODE REF: 2017 NEC 705.12(2)(3)(b) 0 rPH WARNING OTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS WARNING A GENERATION SCOURGE IS CONNECTED TO THE SUPPLY (UTILITY) SIDE OF THE MAIN SERVICE DISCONNECT. FOLLOW THE PROPER , LOCK-OUT/TAG-OUT PROCEDURES TO ENSURE THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH IS OPENED PRIOR TO PERFORMING WORK ON THIS DEVICE LABEL LOCATION: (IF APPLICABLE) SUPPLY SIDE TAP CODE REF: UTILITY LABEL LOCATION: MAIN PANEL AC DISCONNECT(S) CODE REF: NEC 690.54 � ID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 6\ LABEL LOCATION: MAIN PANEL CODE REF: NEC 690.12 WARNING 7 ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: COMBINER PANEL AC DISCONNECT JUNCTION BOX INVERTER(S) CODE REF: NEC 690.13(b) LABEL LOCATION: DEDICATED KWH METER CODE REF: NEC 690.4(B) UTILITY A LABEL LOCATION: AC COMBINER PANEL CODE REF: NEC 690.12(B) OWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT,COMBINE BOX CODE REF: NEC 690.13(B) OLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: SERVICE METER MAIN PANEL CODE REF: UTILITY WARNING mINVERTER OUTPUT CONNECTION DO NOT RELOACATE THIS OVERCURRENT DEVICE LABEL LOCATION: IF APPLICABLE CODE REF: NEC 705.12(D)(7) LABEL LOCATION: AC DISCONNECT CODE REF: UTILITY OWARNING • ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED SOLAR ELECTRIC PV PANELS A LABEL LOCATION: MAIN SERVICE CODE REF: NEC 690.12 NEC 690.56(C)(1)(A) 12 WARNING PHOTOVOLTAIC POWER SOUR&I LABEL LOCATION: AC DISCONNECT COMBINER BOX SERVICE PANEL CODE REF: NEC 690.5(C) LABEL LOCATION: MAIN PANEL DEAD FRONT CODE REF: NEC 705.12(B)(2)(3)(B) LOCATION: DC CONDUIT JUNCTION BOX NO MORE THEN 1OFT CODE REF: NEC 690.31(G)(3) NEC 690.31(G)(4) REFLECTIVE AND WEATHER RESISTANT LABEL REQUIRES CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8 INCH,WHITE LETTERS ON RED BACKGROUND LABELS SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES EVERY 10FEET, WITHIN 1 FOOT OF TURNS ON BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OF BARRIERS. CONTRACTOR NAME: N/A ADDRESS: N/A PHONE M N/A LICENSE #: N/A REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME U) � N O 00 d� Lu >Q m Q L1J m Lu Lo F-- LLJ � �� Z a SHEET NAME PLACARDS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-7 powered by The new tt.PEAK DUO-G6 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding perfor- mance under real conditions - both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY wi Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5%. In INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE CELLS Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTm. TOP rIaANo vv EXTREME WEATHER RATING �0; 2018 High-tech aluminium alloy frame, certified for high snow (5400Pa) and wind loads (4000Pa). O A RELIABLE INVESTMENT pPm°Poe°° Inclusive 12-year product warranty and 25-year linear o a ,:y Tested ^,J47 performance warranty2. 4'°°°°� STATE OF THE ART MODULE TECHNOLOGY ni a'oo3zsa7 \�' J Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. APT test conditions according tolEC/TS 62804-1:2015, method B (-1500V, 168h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on Rooftop arrays on ^" residential buildings commercial/industrial buildings Engineered in Germany %,.A CE LLS Format 1740mm x 1030mm x 32mm (including frame) Weight 19.9 kg Comm Front Cover 3.2mm thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction box 61-71 mm x 41-50mm x 13-21 mm Protection class IP67, with bypass diodes�� Cable 4mma Solar cable; (+) 1150mm, (-) 1150mm cm a'°"' Connector Multi -Contact MC4, IP68 I�32mm Baca ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE+SW /-OW) Power at MPP' NIP [W] 330 335 340 345 Short Circuit Current' [sc [A] 10.57 10.62 10.68 10.73 Open Circuit Voltage' Vac IV] 39.74 39.99 40.24 40.49 E Current at MPP I- [A] 10.06 10.11 10.16 10.22 Voltage at MPP Valp IV] 32.81 33.13 33.45 33.76 Efficiency' rl [%] z18.4 z18.7 z19.0 z19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOP Power at MPP NIP IWl 246.5 250.2 254.0 257.7 E Short Circuit Current Iu [A] 8.52 8.56 8.60 8.65 e Open Circuit Voltage Vac IV] 37.39 37.63 37.87 38.10 Current at MPP I- [A] 7.92 7.96 8.00 8.04 Voltage at MPP VuPP IV] 31.14 31.45 31.75 32.04 'Measurement tolerances P. x3%;Ix,Vcct5%at STC: 1000W/mz,25x2°C,AMLEG according to IEC 60904-3.1800 W/mz, NMOT, spectrum AM LEG Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE _ At least 98%of nominal power during ocPru 10 T----- m mu°v„„mm w,,;,,,,,,,,,„nm first year. Thereafter max. 0.54% ® - 'm°"°°°^0im m„;.m..,amH --------------- degradation per year. At least 93.1 %f e 8 nominal power up to 10 years. At least a m LL 85%of nominal power up to 25 years. ' All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales m organisation of your respective country. sm °00 800 B0° ' IRMDIANCE tWIMI m Typical module performance under low irradiance conditions in woos comparison to STC conditions(25 "C, 1000W1m2). TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vsc B [%/Kl -0.28 Temperature Coefficient of PuPP Y [%/K] -0.37 Normal Module Operating Temperature NMOT PC] 4333 PROPERTIES"1' SYSTEM DESIGN Maximum System Voltage Vs,s IV] 1000 Safety Class II Maximum Reverse Current IR [A] 20 Fire Rating C Max. Design Load, Push/ Pull [Pal 3600/2667 Permitted Module Temperature -40°C up to+85°C on Continuous Duty Max. Test Load, Push / Pull [Pa] 5400/4000 VDE Quality Tested, IEC 61215:2016; IEC 61730:2016, Application class A This data sheet complies with DIN EN 50380. DVE C NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany I TEL +4910)3494 66 99-23444 1 FAX +49 (0)3494 66 99-230001 EMAIL sales®q-cells.com I WEB www.q-cells.com Engineered in Germany CACELLS CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A LICENSE #: N/A REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME vJ 0 N O>_ 0 � 0 LU Q wMJ W vJ LU W IN- I..1_ Q SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" THINK `_ENE'GY Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters Region: AMERICAS t • r • : • t r t INPUT DATA (DC) IQ7-60-2-US; / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' 235 W - 350 NI + 235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V CONTRACTOR Min/Max start voltage 22 V / 48 V 22 V / 60 V NAME: N/A Enphase The high-powered smart grid -ready n Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II ADDRESS: N/A PHONE#:N/A Enphase IQ 7 Micro- and Enphase IQ 7+ Micro- DC port backfeed current 0 A 0 A LICENSE #: N/A dramatically simplify the installation process while Q 7 a n d I Q 7 PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit REVISIONS OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter DESCRIPTION DATE REV achieving the highest system efficiency. Microinverters Part of the En hase IQ S stem, the IQ 7 and p y Peak output power 20 VA 295 VA Maximum continuous output power 2440 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal (L-L) voltage/range2 240V/ 208V/ 240V/ 208V/ IQ Envoy', Enphase IQ Battery'", and the Enphase Enlighten" monitoring and analysis software. 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz SIGNATURE &SEAL Extended frequency range 47 - 68 Hz 47 - 68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3cycles 5.8Arms 5.8Arms standards set forth by previous generations and undergo over a million hours of power -on testing, Maximum units per 20 A (L-L) branch circuit3 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A enabling Enphase to provide an industry -leading Power factor setting 1.0 1.0 warranty of up to 25 years. Power factor (adjustable) 0.7leading ... 0.7lagging 0.7leading ... 0.7lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 % 97.6 % 97.5 % 97.3 % PROJECT NAME CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA U) % Easy to Install Lightweight and simple Ambient temperature range -400C to +650C Relative humidity range 4%to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) PV2 to MC4: order ECA-S20-S22 PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) ` N 0 nI Productive and Reliable Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - No fans Approved for wet locations Yes O >_ CO Li j Q Optimized for high powered 60-cell and 72-cell* modules Pollution degree PD3 M Y More than a million hours of testing Enclosure Class II double -insulated, corrosion resistant polymeric enclosure LJJ Class II double -insulated enclosure UL listed Environmental category / UV exposure rating NEMA Type 6 / outdoor w J (n \ m IJ FEATURES Communication Power Line Communication (PLC) / L ENPHASIE Smart Grid Ready NO Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, w 'T-- LO O �+ Q Z grid requirements Configurable for varying grid profiles CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC Q Meets CA Rule 21 (UL 1741-SA) and DC conductors, when installed according manufacturer's instructions. * The IQ 7+ Micro is required to support 72-cell modules. U1 1. No enforced DC/AC ratio. See the compatibility calculator at httos://enphase.com/en-us/suonort/module-compatibility. SHEET NAME , 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. EQUIPMENT EM � E N P H AS E I o learn more about Enphase offerings, visit enphase.com �./ To learn more about Enphase offerings, visit enphase.com � © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. E N P H AS E SPECIFICATION SHEET SIZE 2018-05-24 ANSI B 11" X 17" SHEET NUMBER PV-9 /lr IRONRIDGE Built for solar's toughest roofs. Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant Online software makes it simple to create, share, and price projects. 20-Year Warranty Twice the protection offered by competitors. XR Rails O XR10 Rail A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear and black finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear and black finish Clamps & Grounding O UFOs Stopper Sleeves Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Attachments O — FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill and black finish Resources - Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Slotted L-Feet Drop -in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled and lubricated Bonded Splices All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled Design Assistant NABCEP Certified Training —.. _ etERFA PR04 _ Go from rough layout to fully m Earn free continuing education credits, NABCEP _ engineered system. For free. while learning more about our systems. Go to IronRidge.com/design Go to IronRidge.com/training CONTRACTOR NAME: N/A ADDRESS: N/A PHONE #: N/A LICENSE #: N/A ■ REVISIONS - DESCRIPTION I DATE I REV SIGNATURE & SEAL PROJECT NAME Z 3: m LU LL1 ���^ VJ �1 � N 00 J M W Q Q J U) CO LLJ Lr) O IZI- U Q Z Q SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 THINK `_ENE'GY /lr IRON RIDGE Integrated Grounding System Installation Overview - Install Roof Attachments I . • = • ' ' ' Simplified Grounding • Install appropriate roof flashing and/or standoff for roof type. I CONTRACTOR For Greater Safety & Lower Cost - iL •Attach L-Feet to flashing or standoff. ADDRESS: N/A Traditionally, solar modules are grounded by attaching . PHONE#:N/A lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the © Prepare Rail Connections LICENSE #:NIA REVISIONS DESCRIPTION DATE REV array. This process adds time and cost to the installation, Insert splice into first rail, then secure with Grounding Strap and ® and often results in improper grounding, creating self -drilling screw. significant long-term safety risks. • Slide second rail over splice, then secure with opposite end of The IronRidge Integrated Grounding System solves these Grounding Strap and self -drilling screw. SIGNATURE & SEAL challenges by bonding modules directly to the mounting rails. This approach eliminates separate module - grounding hardware, and it creates many parallel Mount & Ground Rails grounding paths throughout the array, providing greater safety for system owners. • Attach rails to L-Feet and level rails. Grounding Mid Clamp •Install one Grounding Lug per row of modules. Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and Connect Grounding Lug to grounding conductor. 9 9 9 9 the mounting rail to form secure electrical bonds, which are repeated throughout the array. Install Modules & Clamps PROJECT NAME �/ i 1/ • Install first module usingEnd Clamps and Grounding Mid Clamps. p 9 p Q /I//��/I//I//�I/ �/ '�� 1 i1I �1/��/��/�/��/ �./��/��/�/•/��/I • Install additional modules using Grounding Mid Clamps. j • Finish row with a second pair of End Clamps. ��/����� ,�/•�%•/��//•//�/ •/ �.,yi��., ®��� ./, •�, Testing &Certification B Module Frame Compatibility J 00 ,II.,,�I, � The IronRidge Integrated Grounding r W Q m Y System has been tested and certified to Dimension Range UL 2703 by Intertek Groulc. p pA 31.Omm - 51.Omm Q w J (n CO W > /� // '�• UL 2703 is a proposed UL standard A B 5.08mm (minimum) Lo F-- W � � \; �►��; -� � ' for evaluating solar module mounting An module frames whose parameters are not listed in the Y P and clamping devices. It ensures these provided table have not been tested for compatibility. Ln O U 3 devices will maintain strong electrical and (%) Q f\� / \ mechanical connections over an extended period of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60-cell and Z Q environments. 72-cell solar module frames with box construction and a range of thicknesses. /�\ anodization 2 \.•may Grounding Strap , The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction of UL 1703, the solar module testingSHEET within the parameters stated above are compatible with the NAME Grounding Straps are used to bond rail -to -rail connections. / Grounding Lug standard, includingtemperature and p IronRidge Integrated Grounding System. humidity cycling, electrical and mechanical EQUIPMENT They are only required on the A single Grounding Lug rail with the grounding lug. an entire row load testing, and manufacturing quality O Go to ironrid ironridge.com/ig 9 g SPECIFICATION of PV modules to the grounding conductor. reviews. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11 THINK `_ENE'GY ZIA IRONRIDGE UFO Family of Components System Diagram Simplified Grounding for Every Application - - I - . r: -- - - - - ---- - - - - -----m- ---- - - - - ---- - -- - - - The UFO family of components eliminates the need for __ coNTRACTOR separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature EA the UFO family —Flush Mount, Tilt Mount and Ground PHONE#: PHONN/A LICENSE #:NIA Mount —are fully listed to the UL 2703 standard. ---------------- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ --———————— — — — — —— —-- ———-- — — — — ——-- — — ---— REVISIONS DESCRIPTION DATE REV UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more s reliable installations. SIGNATURE & SEAL 211L—_ Stopper Sleeve Universal Fastening Object (UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO, converting it into Rails. It comes assembled and lubricated, and — — — — — — — — — _ — — — — — — — _ — — — — — — — — — — — — — — — — — a bonded end clamp. can fit a wide range of module heights. — — — — — — — — — — — — — — — — — _ m _ _ — — — — — — — — — — — — — _ ��• PROJECT NAME �%m" P OUFO Stopper Sleeve • Grounding Lug m Bonded Splice _ Ground Wire U) MAN N 4 Approved Enphase microinverters can provide equipment roundin of IronRid e systems, eliminating the need for Pp p pgrounding 9 Y 9 grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. 00 O J W Q UL CertificationCross-System Compatibility w J U) The IronRidge Flush Mount, > Tilt Mount, and Ground Mount XR Rails d d XR1000 Only W � Bonded Splice / Systems have been listed to UL � O Each Bonded Splice uses e \� self -drilling screws to form a secure connection. No 2703 by Intertek Group plc. UFO/Stopper Bonded Splice d d N/A �� ^^ U V J bonding strap needed. j `� ; FMO15q \� UL 2703 is the standard for z evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array Q systems. It ensures these devices Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 Grounding Lug will maintain strong electrical and & Power Darfon - MIG240, MIG300, G320, G640 SHEET NAME A single Grounding Lug Bonded Attachments mechanical connections over Optimizers SolarEdge P300, P320, P400, P405, P600, P700, P730 an extended period of time in connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-foot to the extreme outdoor environments. Fire Rating Class A Class A N/A EQUIPMENT grounding conductor. rail. It is installed with the same socket as the rest of the Modules Tested or Evaluated with over 400 Framed Modules SPECIFICATION system. O Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-12