Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0655 4410 San Juan Avenue (8)AERIAL VIEW: MAP VIEW: SHEET INDEX: in inityhome _ - - PV01 COVER PAGE �+ SOLUTIONS ! w P ' • = PV02 PROPERTY PLAN p i , " PV03 ROOF PLAN PV04 ROOF ATTACHMENTS + BOM LL _>! c` ry 4 �- � PV05 MOUNTING DETAIL Z /0 ryoo V) ��� W W . } r s A y *4e S'; PV06 ELECTRICAL DIAGRAM Q LL z > �_ W o > O it 2 `_..-~i�%E' .- _yam • �w PV07 LABELS PV08 PLACARD O g a w• f t �X`�i . _ u •+ .=' ° ' 'may PLfkNNING PV09 SITE PHOTOS CITY OF ANACORTES AND BUILDING DEPT: APPROVED PLANS NNW•44} 4 .- REVIEWED FOR CODE COMPLIANCE �*' PE MIT #: BLD-2020-0671 4410 SAN JUAN AVE ti 14- Jr- *�Y -, .,9 ADDRESS: ROVED BY: _ ,T $' : + - ', AP u Q w J `� _ �•. -� x 4' ^ _;1 r _ _ 4 JEC TO FIELD INSPECTION. APPROVED PL S SHALL NOT 0 +iir e.."•vy BE ALTERED WITHOUT AUTHORIZA ON. Y q a O N M a GENERAL NOTES: DESCRIPTION OF DESIGN: 00 INSTALLATION OF GRID -TIED, UTILITY INTERACTIVE PHOTOVOLTAIC SYSTEM < N � ' 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE v + Lij w 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. EQUIPMENT: a) Lu o N m z 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL MAX CONTINUOUS AC SYSTEM SIZE: 6.96 kW AC M c:U o� EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. DC SYSTEM SIZE: 9.86 kW DC z a N 00 o N 3. ALL WIRES INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PV MODULES: (29) Q. Cells Q.Peak DUO BLK-G6+ 340 ° ' � Q o w Y 1D PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 INVERTERS : 29 Enphase IQ7-60-2-US () ( ) p a v g z a RACKING: IRONRIDGE XR FLUSH MOUNT RAILING & ROOF ATTACHMENT SYSTEM - 48" O.C. C ; � d �, 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER o z UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. APPLICABLE GOVERNING CODES: SITE SPECIFICATIONS: Ln U Q cl w 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.81 2017 NATIONAL ELECTRIC CODE [NEC] OCCUPANCY: R-3 l rn '3 N N 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 2015 INTERNATIONAL BUILDING CODE [IBC] ZONING: RESIDENTIAL v v 7• ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. 2015 INTERNATIONAL RESIDENTIAL CODE [IRC] 2015 INTERNATIONAL FIRE CODE [IFC] EXPOSURE CATEGORY: B DATE: September24, 2020 PAGE: SHEET NAME: PV01 COVER PAGE DRAWN BY: SoloCAD in inityhome SOLUTIONS II J -0 °m00 w .� Q 0 L i �w z Lo ° ILL o co (o z> & 1'0 V416]1 EQUIPMENT LEGEND: Q J UTILITY METER o Msp MAIN SERVICE PANEL 00 a rn Ac VISIBLE, LOCKABLE, LABELED Q N � AC DISCONNECT M Lu w v pV METER SOCKET (FOR UTILITY PV METER) O u Z N Y m N c u p ENV INVERTER Q Q oo N O rn o 0 Q O= N v `^° COMBINER BOX � � � O c Z w1' �+ LC LOAD CENTER z V) u N >- IZ H `-' v Q u � � 2 0 d LLI ® FIRE ACCESS PATHWAY (3' TYP) rn rn N N i PROPERTY LINE DATE: September 24, 2020 PV02 PROPERTY PLAN BAT BATTERY(IES) DRAWN BY: SCALE: SoloCAD 1" = 15.05' VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER \ \ \ 1391-311 \ \ \ MP4 \ \ PITCH: 14' \ \ AZIMUTH:300' \ \ \ MP3 \ \ PITCH: 14' AZIMUTH: 300' I JB I JB INV I AC PV I --- JB MP2 PITCH: 14' / MP1 AZIMUTH: 120' PITCH: 14' FRONT OF HOME / AZIMUTH: 120' San loan:p,,:j 4410 _ in inityhome SOLUTIONS II J "0 O : (-o c)m00 w .c: Q O�� 2 Ste_ L L i ~ w O Z Ln c� LL o c� Z > & 1'0 V416]1 Q J EQUIPMENT LEGEND: o O :2 M UTILITY METER 0 a Q N o) v MSP MAIN SERVICE PANEL N M w 1° Ac VISIBLE, LOCKABLE, LABELED °J Lu o j AC DISCONNECT O c Z 00 N METER SOCKET Q Q N Pv (FOR UTILITY PV METER) O ; of o 0 Q v < O N �Q NV INVERTER M Z VI d � D Z Lu O� c Z w Li- " �+ c COMBINER BOX M V) u N O X U� CL Lu V) L 'u v Q o C Lu �c LOAD CENTER rn rn N N ® FIRE ACCESS PATHWAY (3' TYP) DATE: September 24, 2020 PAGE: SHEET NAME: PV03 ROOF PLA BATr BATTERY(IES) DRAWN BY: SoloCAD PITCF AZIMUTH: PITC AZIMUTI- VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER FRONT OF HOME in inityhome SOLUTIONS Z O (n O O -j-0QO O? co O Z co 0°°M — w.�Q oa JB U I —_ L L: w o ~ Z Z Lf) 0 � O LL C c� U z co > JB I NV AC U Q w J p Y O PV ONO am .. w aN 7m d o n rnL w JB a)Luo Y M JB u mz c:u a� QQ0 Z N V) p O > Y O � � Q O w a z N a � a PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: MOUNTING EQUIPMENT QTY: FRAMING INFO: ROOF ATTACHMENT COUNT: 66 o oEu z v) ROOF ATTACHMENT COUNT: (66) RAFTER SIZE: 2X4 m u PV MODULE COUNT: 29 ARRAY AREA: MODULE COUNT * 18.06ft2 - 523.74 -i Q w PV MODULE COUNT: (29) RAFTER SPACING: 24" ROOF AREA: 2049 ft2 MID CLAMP COUNT: (42) FRAMING TYPE: Rafters N N DATE: September24, 2020 PERCENT OF ROOF COVERED: 26% END CLAMP QTY: (32) ARRAY WEIGHT: MODULE COUNT * 501bs = 1450 PAGE: SHEET NAME: (8) DISTRIBUTED LOAD: ARRAY LBS/ATTACHMENTS = 21.97 PV04 ROOF ATTACHMENTS +gOM SPLICE COUNT: DRAWN BY: SOloCAD 7F IPOINT LOAD: (IbS/ft2) (ARRAY) WEIGHT/AREA = 2.77 Ibs/ft2 ATTACHMENT SPACING: 48 in inityhome SOLUTIONS U) Z O J -0 co O ro (n m 00 LLI C Q O _ S L' L i ~ Lu o Z � � LL o c� Z � > U w Q J � o Y 0 ONO d an w Q N O n zT cn � rn w CC a)Luu L L mow\ \ O } Z MV) mN a� QQ00 Z N aJ N CJl 0 O Q O w a '"^"'RIDGE UNIVERSAL ENING OBJECT IRONRIDGE RAIL 1 END CLAMP DETAILS IRONRIDGE UNIVERSAL FASTENING OBJECT PV MODULE FRAME IRONRIDGE RAIL 2 MID CLAMP DETAILS PV MODULE IRONRIDGE XR RAIL (E) COMP SHINGLE ROOF (1 LAYER) IRONRIDGE FLASHFOOT2 ASSEMBLY FLASHING (SEE DATASHEET FOR DETAILS) 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT (PER MANUFACTURER) (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING Q z N a PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: z E 0 0 Ln ROOF ATTACHMENT COUNT: 66 LL v �0� v� z "' `' > Q PV MODULE COUNT: 29 -i Q C� w ARRAY AREA: MODULE COUNT * 18.06ft2 = 523.74 ROOF AREA: 2049 ft2 N N DATE: September24, 2020 PERCENT OF ROOF COVERED: 26% PAGE: PV05 SoloCAD SHEET NAME: ARRAY WEIGHT: MODULE COUNT * 501bs = 1450 MOUNTING DETAIL DISTRIBUTED LOAD: ARRAY LBS/ATTACHMENTS = 21.97 POINT LOAD: (Ibs/ft') (ARRAY) WEIGHT/AREA = 2.77 Ibs/ft2 V-8" 48" MAX." MAX. IRONRIDGE XR RAIL FLASHFOOT2 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORD FRONT VIEW 10" MIN - 7 1 '-411 MAX r SIDE VIEW MOUNTING EQUIPMENT QTY: PV MODULE IRONRIDGE XR RAIL i 3 2'-8" MIN - 3'-10" MAX (E) RAFTER/TOP CHORDS 10" MIN - 17 1 ' —4" MAX FRAMING INFO: ROOF ATTACHMENT COUNT: (66) RAFTER SIZE: 2x4 PV MODULE COUNT: (29) RAFTER SPACING: 24" MID CLAMP COUNT: (42) FRAMING TYPE: Rafters END CLAMP QTY: (32) SPLICE COUNT: (8) ATTACHMENT SPACING: 148 WIRE SCHEDULE (1) 6 AWG THWN-2 COPPER - (11) 1 (1) 12-2 TC-ER, THWN-2, COPPER (OR CODE APPROVED EQUIVALENT) (1) 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER -(POSITIVE) (1) 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER -(NEGATIVE) (2) 10 AWG THHN/THWN-2, COPPER - (L1) (2) 10 AWG THHN/THWN-2 COPPER- (1-2) (1) 6 AWG THWN-2 COPPER - (1-2) (1) 6 AWG THWN-2 COPPER - (NEUTRAL) (1) 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER -(GROUND) (1) 10 AWG THHN/THWN-2 (GROUND) (1) 10 AWG THWN-2 COPPER - (GROUND) in inityhome (1) 6 AWG BARE, COPPER (GROUND) (1) 3/4" LIQUID TIGHT OR EMT OR FMC CONDUIT: 3/4" LIQUID TIGHT OR EMT (1) CONDUIT: 3/4" LIQUID TIGHT OR EMT SOLUTIONS (OR CODE APPROVED EQUIVALENT) (OR CODE APPROVED EQUIVALENT) (OR CODE APPROVED EQUIVALENT) Z O (n H Z O O (0 z U)m00 w �Q O 0�� 2 L Ste_ L i ~ LJJ O ZZ U SUPPLY SIDE CONNECTION: (E)200A MAIN SERVICE PANEL LO O u NEC 230.46, NEC 230.79, (E)200A / 2P MAIN BREAKER Z STRING (1): 14.0 A AC NEC 705.12(A) ENPHASE (X-IQ-AM1-240-3) AC COMBINER BOX PV AC DISCONNECT (E) UTILITY METER 14 MODULES SOLAR LOADS ONLY FUSED, AIC 10kA UL 1741 COMPLIANT VISIBLE, LOCKABLE, LABELED, OPEN UTILITY PV PRODUCTION 60A, 240V, 2-POLE METER BASE (E) 200A-2P STRING (2): 15.0 A AC J-BOX (N) 40A FUSES (E) LOADS 1 2 15 MODULES (2) 20A-2 (E) v) � OLE I I I I >Q 0 Y � a G J BOX J BOX 4 4 4 N 120/240 VAC TO UTILITY GRID rn .. G N M w 1 2 3 vi � l+0 � AHD C7w o } Z GROUNDING &GENERAL NOTES: M N c u "0 co N O INTERCONNECTION NOTES 1. A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [NEC[ VISIBLE, LOCKABLE, Q Q N 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 690.47(C)(3)] LABELED AC DISCONNECT (E) GROUNDING Z (1 `) > 215.91 & [NEC 230.951 2. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. LOCATED WITHIN 10' ELECTRODE - 0 O w Q Z) N rYa ai I� 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING OF UTILITY METER Z in a C1 [NEC705.12(A)] WITH SERVICE ENTRANCE CONDUCTORS IN F- 2 C7 ai ACCORDANCE WITH [NEC 240.21(B)] ELECTRODE EQUIPMENT SCHEDULE: O c Z w w O F- �' ^ 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS TYPE: QTY: DESCRIPTION: RATING: Z cn U N p X N NM U Q C DISCONNECT NOTES FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL MODULES: (29) Q. Cells Q.Peak DUO BLK-G6+ 340 340 W F- `-'Lu Q u "' 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT INSPECTION. INVERTERS: (29) Enphase IQ7-60-2-US 240 W WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING 5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE N N LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE AC DISCONNECT(S): TYPE TRANSITIONS. (1) PV AC DISCONNECT, 240V, 2-POLE 60 A DATE: September 24, 2020 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER PAGE: SHEET NAME: PV06 ELECTRICAL DIAGRAM PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH. 3. FUSED AC DISCONNECT TO BE USED. AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. DRAWN BY: SoloCAD in inityh0me SOLUTIONS Z O ry 0 LL Z 0' 0 Q Z 0 U) Z o_ H J 0 U) w 0 2 H Z_ LL Z m c W u') O 00 Q m O U C M U Q w J 0 Y O 00 a rn . Lu Q o in N M w AHD (7w > O u Z N Y m N cut.0 Q Q oo OZ) N O ; Z) of D o �<0Lu N ram 41 Z cn d cf o(D Zw °n z m v)U N U >_ I= N N DATE: September 24, 2020 PV07 LABELS DRAWN BY: SoloCAD AWARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION r. RATED AC OUTPUT CURRENT 29 A NOMINAL OPERATING AC VOLTAGE 240 V &WARNING I DUAL POWER SUPPLY I SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABELING NOTES: LABEL 1 AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING SERVICE. NEC. 690.35(F) LABEL 2 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.17(E), NEC 705.22 LABEL 4 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. NEC 690.54, NEC 690.13 (B) LABEL 5 AT POINT OF INTERCONNECTION FOR EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FORM MULTIPLE SOURCES, EACH SERVICE EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCE LOCATIONS. NEC 705.12(D)(3) LABEL 6 AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 1OFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. NEC 690.31(G)(3&4) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCUIRRENT DEVICE PHOTOVOLTAIC SYSTEM EQUIPPED WITH D SHUTDOWN A WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OFALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF"PCSITIONTo sanaeamc SHUT DOWN PV SYSTEM wr^ s AND REDUCE SHOCK HAZARD IN THE ARRAY R1 tit 1 1 RAPIDSHUTDOWIN SWITCH TO THE "OFF° POSITION TO SHUTDOWN CONDUCTORS ------, OUTSIDE THE ARRAY CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.211 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] JUNCTION BOX LABEL 7 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. NEC 705.12(D)(2)(3)(B) LABEL 8 SIGN LOCATED AT UTILITY SERVICE EQUIPMENT. NEC 690.56(C) LABEL 9 (ONLY IF 3 OR MORE SUPPLY SOURCES TO A BUSBAR) SIGN LOCATED AT LOAD CENTER IF CONTAINS 3 OR MORE POWER SOURCES. NEC 705.12(D)(2)(3)(C) LABEL 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 11 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABELING DIAGRAM: PV COMBINER SUBPANEL- IF USED TO COMBINE PV OUTPUT CIRCUITS AC DISCONNECT M El El ---- El --- -- o MAIN SERVICE PANEL (E) SUB PANEL (ONLY IF POINT OF �2 INTERCONNECTION IS MADE WITHIN �4 SUB PANEL) ❑ o 0 5 El El ❑ o00 8 l 10 OR 11 El a (ONLY IF PV (ONLY IF PV INTERCONNECTION INTERCONNECTION CONSISTS OF LOAD CONSISTS OF LOAD SIDE BREAKER) SIDE BREAKER) ** ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE. ** in inityhome CAUTIONSOLUTIONS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED z O SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: U) z < O_ O —1-0co z U) m 00 PV ARRAY ui Q O0 pad 2 LL W O ~ z z INVERTER & RAPID B E= o z SHUTDOWN DC e coo DISCONNECT SWITCH 'NV AG PV AC DISCONNECT M MSP J5Je MAIN DISTRIBUTION UTILITY DISCONNECT FRONT OF HOME U w Q J 0 4410 San Juan Ave, Anacortes WA 98221 ONO d Q N � ' DIRECTORY + � PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE L U o Uj SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. O } J Z � N Y m N "O aaco � 1° N z (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: ? M 0 6 °' °—Qow �� NEC 690.56(B)&(C), [NEC 705.101) N N rZ � v "o Z cn a Ci Of v OC7 Li- z v r00� v� Ln U } U Q LU ''-'0 < C1w N N DATE: September 24, 2020 PAGE: SHEET NAME: PV08 PLACARD DRAWN BY: SoloCAD SITE PHOTOS: in init home YSOLUTIONS z O Q 75 ry O LL Z ry 0 U Q ry Z O U m Lu L() 0 co U w Q J 0 Y � � cp G ONO d an w Q N o n ZT cn � rn w � CC a) Lu U L L (> Lu > O } J Z M N Y m N O Q Q 00 Z N aj N M 0 O QOw N cow aJ cc v p C7 Z LL LL v COI— Z Ln U Vn v� } � '-'0Qv U Q C1w vi���0 rnrn N N DATE: September 24, 2020 PAGE: SHEET NAME: PV09 SITE PHOTO: DRAWN BY: SoloCAD ip powered by bill* THE IDEAL SOLUTION FOR: Rooftop arrayson residential buildings MECHANICAL SPECIFICATION Format 68.5 x 40.6 x 1.26 in (including frame) (1740 x 1030 x 32 mm) �'0.'0°mm) ssoyseomm) Weight 43.9lbs(19.9kg) - - --- _ . s.slsssomm) _ Front Cover 0.13in (3.2mm) thermally pre -stressed glass with anti -reflection technology a.om uMFg P°Imam 0.1]T 14.Smm) Fmme Back Cover Compositefilm sesxleenmm) ■d Frame Black anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half cells ED Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71 in (53-101 x 32-60 x 15-18 mm), Protection class IP67, with bypass diodes 1e°°�� °Isssomm) Cable 4mm2 Solar cable; (+)>-45.3in(1150mm),(-)>-45.3in(1150mm) --11- 9KDr.�re9m nw.. Connector Staubli MC4, Hanwha Q CELLS HQC4, Amphenol UTX, -4,. mu^d^9 (DETAIL A) _ Renhe 05-6, Tongling TL-CableOlS, JMTHY JM601; IP68 or-If-a2.-IN mm) -LA Friends PV2e; IP67 0.986'(24.5mm1I_0 I0.935y0.6mm) • ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE+5 W /-0 W) Power at MPP' PNPP [w] 330 335 340 345 QCELLS E Short Circuit Current' 6[A] 10.41 10.47 10.52 10.58 Open Circuit Voltage' Voc [V] 40.15 40.41 40.66 40.92 EUPD RESEARCHCurrent at MPP INPP [A] 9.91 9.97 10.02 10.07 TOP BRAND PV oDeStyreseed � VOltageatMPP VNPP [V] 33.29 33.62 33.94 34.25 ow,oma eMp E�soEE Efficiency' q [%] >_18.4 >_18.7 >-19.0 >-19.3 2UW9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 - / Damro.cam lo.40032567 Power at MPP PNPP [W] 247.0 250.7 254.5 258.2 E Short Circuit Current Isc [A] 8.39 8.43 8.48 8.52 E Open Circuit Voltage Voc IV] 37.86 38.10 38.34 38.59 'c Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Current at MPP INPP [A] 7.80 7.84 7.89 7.93 Higher yield per surface area, lower BOS costs, higher Voltage at MPP VNPP IV] 31.66 31.97 32.27 32.57 power classes, and an efficiency rate of up to 19.5 %. 'Measurement tolerances PNPP m3%; Isc; Voc t5% at STC:1000 W/m2, 25m2°C, AM 1.5 according to IEC 60904-3.2800 W/m2, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE INNOVATIVE ALL-WEATHER TECHNOLOGY n7 oe - �];w _:�." %'a -°°"*' __ -- At least98%of nominal al powt93.1% W ux Eao At least 98%of nominal powercuring 7°60 T Optimal yields, whatever the weather with _ y ` excellent low -light and temperature behavior. LL o 9 p y of nominal power up to 10 years. At --------------- a c 25 ye of nominal power up to ENDURING HIGH PERFORMANCE cQ w as. Full warrantiessuremnttoleanc B0 sr uo eoo m Long-term yield security with Anti LID and Anti PID Technologyl, All data within measurementtoleranc- \/ Hot -Spot Protect and Traceable Quality Tra.QTm. 00 the warranty terms of the Q CELLS IRRADIANCE [W/mI] o ]° sales organization of your respective EXTREME WEATHER RATING 9 u ,9 country. High-tech aluminum alloy frame, certified for high snow YEARS comTypical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2) (5400 Pa) and wind loads (4000 Pa). TEMPERATURE COEFFICIENTS Temperature Coefficient of Is, a [%/K] +0.04 Temperature Coefficient of VDc [%/K] -0.27 A RELIABLE INVESTMENT Temperature Coefficient of PNgg Inclusive25-year product warranty and25-year p Y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] 109t5.4(43t3°C) linear performancewarranty2. PROPERTIES FOR SYSTEM DESIGN Maximum System VoltageVsysIV] 1000(IEC)/1000(UL) Safety Class II STATE OF THE ART MODULE TECHNOLOGY Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI /UL 1703 C (IEC)/TYPE 2 (UL) Q.ANTUM DUO combines cutting edge cell separation Max. Design Load, Push/Pull' [Ibs/ft] 75(3600Pa)/55(2667Pa) Permitted Module Temperature-40°Fupto+185°F and innovative wiring with Q.ANTUM Technology. Max. Test Load, Push/Pulls [Ibs/ft2] 113 (5400PEI(4000Pa) "Continuous Duty (-40°C up to+85°C) ' APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) sSee Installation Manual 2 See data sheet on rear for further information QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ILL 1703, VIDE Quality Tested, CE-compliant, IEC 61215:2016, IEC 61730:2016, Number of Modules per Pallet 32 Application Class II, U.S. Patent No. 9,893,215 (solar cells) Number of Pallets per 53' Trailer 28 SA® Number of Pallets per 40' HC-Container 24 DVE C E c�,^„„us Pallet Dimensions(LxWxH) 71.5x45.3x48.01n(1815x1150x1220mm) Pallet Weight 1505lbs (683kg) Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved Installation and use of this product. CELLS 400 Spectrum t CELLS Center Drive, Engineered in Germany 400 Spectrum Center Drive, Suite 1400,Irvine, CA 92618, USA I TEL +1949 74859961EMAIL inquiry®us.q-cells.coml WEB www.q-cells.us Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ7and IQ 7+ Microinverters a To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'"" and Enphase IQ 7+ MicrOTM dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnvoyT", Enphase IQ BatteryT", and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+ Micro is required to support 72-cell modules. � ENPHASE, Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' Module compatibility Maximum input DC voltage Peak power tracking voltage Operating range Min/Max start voltage Max DC short circuit current (module Isc) Overvoltage class DC port DC port backfeed current 235 W - 350 W + 60-cell PV modules only 48 V 27V-37V 16V-48V 22V/48V 15A OA 235 W - 440 W + 60-cell and 72-cell PV modules 60 V 27V-45V 16V-60V 22V/60V 15A OA PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range2 240 V / 208 V / 240 V / 208 V / 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit3 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range Relative humidity range Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Dimensions (WxHxD) Weight Cooling Approved for wet locations Pollution degree -400C to +65°C 4% to 100% (condensing) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA-S20-S22 PV2 to UTX: order ECA-S20-S25 212 mm x 175 mm x 30.2 mm (without bracket) 1.08 kg (2.38 Ibs) Natural convection - No fans Yes PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (LIL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at https:Henphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Referto local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com u E N P H A S E © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) UL LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner 3T" with Enphase IQ EnvoyTM consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty • UL listed ENPHASE Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy'" printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5°i) and optional* consumption monitoring (+/- 2.5°i). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect'" CELLMODEM-03 (4G / 12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G / 5-year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M / 5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole,1 OA, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole,15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65 A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64 A Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre -installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 Ibs) Ambient temperature range -400 C to +460 C (-400 to 1150 F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance, Combiner UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 * Consumption monitoring is required for Enphase Storage Systems To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. E N P H A S E 2018-09-13 v /lam IRONRIDGE Solar Is Not Always Sunny XR Rail Family XR Rail Family Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. A XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Corrosion -Resistant Materials XR Rails are Iron Ridge offers All XR Rails are made of 6000-series compatible with a range of tilt leg aluminum alloy, then protected with an FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof roof mounting and structural corrosion, while also providing attachments. applications. a more attractive appearance. §:6 The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. 6' spanning capability Moderate load capability Clear & black anodized finish Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. 8' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. None 10-20 30 40 50-70 80-90 100 120 140 XR10 160 100 120 140 160 100 160 100 160 160 _" 160 ail Span W 10, XR100 XR1000 © 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.13 /lam IRONRIDGE FlashFoot2 The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both _ elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. I r_ Twist -On Cap FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric = = load path. Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Flush Mount System components. I Installation Features Three -Tier Water Seal IR FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. /An eievacea piacrorrn ulverts water away from the water seal. Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2 is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. Testing & Certification Structural Certification A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. B Rounded Corners Makes it easier to handle and insert under the roof shingles. C Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. 1200 1000 aoo Q 600 rG aoo n 200 0 FEashFoas2 FlashFoot ■ Leading Competitor 1 2 Rail -to -Lag Offset (in) Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. f Low-cost Competitor Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0