Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0772 4115 Oakes Avenue (18)G1� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT �COg building plans.pdf Markup Summary robf (9) Please revise energy credits to reflect 2018 WSEC. pleaae vrooide dimenaiona on s miil plan pages, o the waY it is done on the foundation Subject: Text Box Page Label: 2 Author: robf Date: 1/10/2022 2:44:44 PM Status: Color: ■ Layer: Space: Subject: Area Measurement Page Label: 2 Author: robf Date: 1/11/2022 10:39:33 AM Status: Color: ■ Layer: Space: Subject: Callout Page Label: 2 Author: robf Date: 1/26/2022 8:04:30 AM Status: Color: ■ Layer: Space: Subject: Callout Page Label: 4 Author: robf Date: 1/11/2022 11:06:30 AM Status: Color: ■ Layer: Space: Please revise energy credits to reflect 2018 WSEC. 3,160.56 sf Please provide geotech approval of building location and site preparation. This will require a geotech report prior to issuing the permit, as well as a geotech assessment of the site prep and footing forms prior to pouring the footings. Please provide dimensions on floor plan pages, similar to the way it is done on the foundation pages. City of Anacortes 1904 6th ST, Anacortes, WA 982211 360-293-1901 1 buildingpermit@cityofanacortes.org I www.anacorteswa.gov G1T Y O� �C0 UPC 414.3 Air gap at r dishwasher. UPC 909 Island sink venting to meet UPC 909. ® R312 G—, per IRG— 36"he19v min. so 'hat] a 4- ph.. cannot pass throagh. Handrails end a-M shall be designed io resisi a ceniraietl loatl of 200 Dountls. lrh, tliate nd pane and cables, balusters l fillers :hell be designed in ..ita nwpirated I— of50pounds.IBG1607.8.1.2 DECK 1B'X 12'q" a Exterior walls are required to be insulated. Please provide revised drawings that reflect this. 5LA5 REC ROOM 22-9"X 13' PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT ------------------------------ Subject: Text Box Page Label: 4 Author: robf Date: 1/11/2022 2:31:45 PM Status: Color: ■ Layer: Space: Subject: Text Box Page Label: 4 Author: robf Date: 1/11/2022 2:35:09 PM Status: Color: ■ Layer: Space: Subject: Text Box Page Label: 5 Author: robf Date: 1/26/2022 8:06:31 AM Status: Color: ■ Layer: Space: Subject: Callout Please provide Page Label: 6 detail for Author: robf cantilever framing. Date: 1/26/2022 8:34:13 AM Status: Color: ■ Layer: Space: Ene g Please indicate Min R1 proposed ceiling Min R4 insulation. Min R2 Min Ri Min Wi Energ} 1a. Ef 3a. Hi ------------------------------- Subject: Callout Page Label: 9 Author: robf Date: 1/11/2022 12:14:07 PM Status: Color: ■ Layer: Space: UPC 414.3 Air gap at dishwasher. UPC 909 Island sink venting to meet UPC 909. R312 Guards per IRC — 36" height min, so that a 4" sphere cannot pass through. Handrails and guards shall be designed to resist a concentrated load of 200 pounds. Intermediate rails and cables, balusters and panel fillers shall be designed to resist a concentrated load of 50 pounds. IBC 1607.8.1.2 Exterior walls are required to be insulated. Please provide revised drawings that reflect this. Please provide detail for cantilever framing. Please indicate proposed ceiling insulation. City of Anacortes 1904 6th ST, Anacortes, WA 982211 360-293-1901 1 buildingpermit@cityofanacortes.org I www.anacorteswa.gov