Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0772 4115 Oakes Avenue (10)G1T Y O� 17A PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT 0 -1cpg`t. 1414 7th Garage 7.pdf Markup Summary (4) k � GGtaroc.9 G i Please provide completed Stormwater minimum [ requirement #2 packet. If roof system is designed as a antral beam, the collar ties may be.mided and the rafters may be retl — to 2X6 HF #2 or belle,. YP� Mlnlmum beam size would be 3 1Y X15 GLB or 51/ X13112" t: GLB. If the ceiling joists are lifted above the wall tops, this reduces the rafter spans t. 0.61 of Ma span tables. 2X10 minimum rafters if ridge board and collar tie method used. 3AJ6. Z .26,�'i� zxa RI06� s�cyr_3at Subject: Text Box Page Label: 5 Author: robf Date: 10/11/2021 8:43:48 AM Status: Color: ■ Layer: Space: Subject: Callout Page Label: 15 Author: robf Date: 10/11/2021 8:31:14 AM Status: Color: ■ Layer: Space: Subject: Text Box Page Label: 15 Author: robf Date: 10/11/2021 8:38:38 AM Status: Color: ■ Layer: Space• Please provide completed Stormwater minimum requirement #2 packet. Ceiling joist required in bottom third of wall to ridge height. If roof system is designed as a central beam, the collar ties may be omitted and the rafters may be reduced to 2X6 HF #2 or better. Minimum beam size would be 3 1/2 X 15 GLB or 5 1/2 X 13 1/2" GLB. If the ceiling joists are lifted above the wall tops, this reduces the rafter spans to 0.67 of the span tables. -------------------------------------------------------------------------------------------------------- Subject: Callout Page Label: 15 Author: robf Date: 10/11/2021 8:32:26 AM Status: Color: ■ Layer: Space: 2X10 minimum rafters if ridge board and collar tie method used. City of Anacortes 1904 6th ST, Anacortes, WA 982211 360-293-1901 1 buildingpermit@cityofanacortes.org I www.anacorteswa.gov