HomeMy WebLinkAboutPermit File BLD-2020-0772 4115 Oakes Avenue (5)17A PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT 0 -1c0ZL 2. AFC - 2702 Commercial Ave - 24 X 36 PERMIT SET 1.2 updated 1-10-22 - Copy with building comments.pdf Markup Summary robf (3) 2000 GPM Fire flow from 2 hydrants, or sprmW.rs required. Provide fire fiav report. �3o�°ga fire ° Subject: Text Box Page Label: 1 Author: robf Date: 1/11/2022 3:24:58 PM Status: Color: ■ Layer: Space: Subject: Text Box Page Label: 1 Author: robf Date: 1/11/2022 3:25:02 PM Status: Color: ■ Layer: Space: ------------------------ - - - - -- Subject: Callout Page Label: 11 Author: robf Date: 1/11/2022 2:56:12 PM Status: Color: ■ Layer: Space: Please provide WSEC compliance documents for lighting and HVAC. 2000 GPM Fire flow from 2 hydrants, or sprinklers required. Provide fire flow report. IBC 718.4 requires draft stops at 3000sq ft increments or above fire partitions. I'm not seeing either of those situations here. City of Anacortes 1904 6th ST, Anacortes, WA 982211 360-293-1901 1 buildingpermit@cityofanacortes.org I www.anacorteswa.gov