HomeMy WebLinkAboutPermit File BLD-2018-0695 4113 R Avenue (7)STRUCTURAL NOTES
(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)
CODE
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,
SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS
WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION.
DESIGN LOADS
DEAD LOADS:
ROOF 12 PSF
FLOOR 12 PSF
LIVE LOADS:
ROOF (SNOW LOAD) 25 PSF
RESIDENTIAL 40 PSF
DECK 60 PSF
EARTHQUAKE LOADS:
EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-10 SECTION 12.8.
SITE CLASS D
SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.106
ONE SECOND SPECTRAL RESPONSE ACCEL (Si) 0.437
SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) 0.780
ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.455
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR 00 1.0
SEISMIC DESIGN CATEGORY D
BASIC SEISMIC FORCE -RESISTING -SYSTEM PLYWOOD SHEAR WALLS
RESPONSE MODIFICATION FACTOR, (R) 6.5
REDUNDANCY FACTOR (p) 1.0
SEISMIC RESPONSE COEFFICIENT (CS) 0.120
W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-10 SECTION 12.7.2.
SS
BASE SHEAR (V), V = CSW = RID
I W
WIND LOADS:
BASIC WIND SPEED (3 SECOND GUST) 115 MPH
EXPOSURE B
KZT 1.0
SPECIAL INSPECTIONS
SPECIAL INSPECTIONS SHALL BE PROVIDED IF REQUIRED BY THE CITY OF ANACORTES BUILDING DEPARTMENT.
STRUCTURAL OBSERVATION IS NOT REQUIRED.
FOUNDATIONS: SPREAD FOOTINGS
ALLOWABLE SOIL PRESSURE: 2000 PSF (ASSUMED)
FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND
AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS
ABOVE, UNLESS NOTED OTHERWISE.
IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR
MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE
THAN 10% FINES (PASSING THE#200 SIEVE).
FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE
THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM
TEST METHOD D1557-00.
CONCRETE
ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH SECTION
CHAPTER 5 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE
FOR BUILDINGS (ACI 301).
ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS
PER CUBIC FOOT.
CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS:
MAXIMUM
MIN CEMENT
TYPE OF CONSTRUCTION
f'c
WATER/CEMENT
CONTENT PER CUBIC
MAXIMUM
SHRINKAGE STRAIN
RATIO
YARD
*ALL CONCRETE
3000 PSI
0.55
5 1/2 SACK
N/A
THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS
SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING
ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE
AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND
SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 5 OF ACI 318.
ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE
WITH ACI 318 TABLE 4.2.1 FOR MODERATE EXPOSURE CONDITION.
* PROVIDE 3000 PSI TO MEET DURABILITY REQUIREMENTS. 2500 PSI Pc CONCRETE MEETS STRENGTH
REQUIREMENTS FOR DESIGNED FOOTING, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy
= 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED
SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL
PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE
SUBMITTED.
REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI
318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS
SHALL BE PER SCHEDULE.
REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING
EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN
HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL
ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS.
MINIMUM LAPS AND EMBEDMENT
UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED
BELOW:
fc = 2500 PSI
DEVELOPMENT LENGTH
LAP SPLICE
BAR
TENSION
COMPRESSION
TENSION
COMPRESSION
SIZE
TOP BARS
OTHER BARS
ALL BARS
TOP BARS
THE
BAR#3
ALL BARS
24
18
9
30
23
12
#4
31
24
12
41
31
15
#5
39
30
15
51
39
19
#6
47
36
18
61
47
23
#7
68
53
21
89
68
27
#8
78
60
24
102
78
30
NOTE:
1. ALL LENGTHS ARE IN INCHES.
2. ALL LAP SPLICES ARE CLASS B.
3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF
CONCRETE IS CAST IN THE MEMBER BELOW THE BAR.
CONCRETE COVER ON REINFORCING
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
CONCRETE EXPOSED TO EARTH AND WEATHER:
#5 BARS AND SMALLER 1 1/2"
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS, WALLS AND JOISTS 3/4"
COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2"
CONCRETE GENERAL NOTES
VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE
NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A
HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS.
ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO
POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED
BEYOND JOINT.
BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR
APPROVED BY THE STRUCTURAL ENGINEER.
SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND
OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS
NOTED.
LUMBER
ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA
GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS:
SIZE CLASSIFICATION
SPECIES
GRADE
Fb (PSI)
Fc (PSI)
SLEEPERS
DOUG-FIR
STUD
700
-
LIGHT FRAMING (STUDS)
HEM -FIR
STUD
675
800
2x JOISTS AND PLANKS
HEM -FIR
#2
850
-
PLATES AND BLOCKING
HEM -FIR
#2
850
-
6x AND LARGER BEAMS AND
STRINGERS
DOUG-FIR
#2
875
-
4x AND SMALLER BEAMS AND
STRINGERS
HEM -FIR
#2
850
-
ALL POSTS AND TIMBERS
DOUG-FIR
1 #1
1200
1000
REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS.
UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN
CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY
VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1.
NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD
ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR
WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.9.1 NAILING
SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL
MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES:
NAIL
SHANK 0
MIN LENGTH
8d COMMON
0.1310
2 1/2" SHANK
10d COMMON
0.1480
3" SHANK
12d COMMON
0.1480
3 1/4" SHANK
16d COMMON
0.1620
3 1/2" SHANK
10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING
MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED
WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS
ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS
OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE
SHANK AND THREADED PORTIONS PER NDS 11.1.3.
CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG
TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED
BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS,
SCREWS, OR BOLTS IN EACH MEMBER.
INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE
(MINIMUM) AS MEMBERS CONNECTED.
GALVANIZATION
UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED
ACCORDING TO THE FOLLOWING TABLE:
GALVANIZATION
UNTREATED
WOOD
CCA-C
SBX
ACQ-C
ACQ-D
CBA-A
CA-B
OTHER
BORATE
ACZA
OTHER PT
WOOD
G90
X
X
X
G 185
X
X
X
X
X
X
HDG
X
X
X
X
X
X
STT300
j X
I X
I X
I X
I X
j X
I X
j X
G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA
G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA
HDG = HOT DIP GALVANIZED
SST300 = TYPE 316L STAINLESS STEEL
TIMBERSTRAND, MICROLLAM, AND PARALLAM MEMBERS
FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT
NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A
STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME,
PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED. MEMBERS
SHALL MEET THE FOLLOWING MINIMUM STANDARDS:
SIZE CLASSIFICATION
SPECIES
GRADE
Flo (PSI)
Fv (PSI
Fc (PSI)
BEAMS & POSTS (d < 9 1/2")
LSL
1.3E
1,700
425
1,835
RIMS & BEAMS (d >_ 9 1/2")
LSL
1.55E
2,325
310
-
BEAMS & POSTS
LVL
2.0E
2,600
285
2,510
POSTS (d < 9 1/2")
PSL
1.8E
2,400
190
2,500
BEAMS (d >_ 9 1/2")
PSL
2.2E
2,900
290
-
TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS.
UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER
MANUFACTURES RECOMMENDATIONS.
RATED SHEATHING
RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE
IN CONFORMANCE WITH IBC STANDARD 2303.1.4.
EXISTING BUILDING
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING
DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE
REDESIGN.
CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS
PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH.
w N/ wv
SHOP DRAWINGS
SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL
ENGINEER FOR REVIEW PRIOR TO FABRICATION:
1. STRUCTURAL STEEL
SHOP DRAWINGS SHALL BE REVIEWED, REVISED AS REQUIRED FOR FIELD CONDITIONS, AND DATE STAMPED BY THE
CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER. FABRICATION SHALL BEGIN ONLY AFTER SHOP DRAWINGS
BEARING THE STAMP AND SIGNATURE OF THE PROJECT ARCHITECT, ENGINEER OF RECORD, AND CONTRACTOR
HAVE BEEN RECEIVED.
STRUCTURAL STEEL
STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC
"SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST
EDITION.
SHAPES SHALL CONFORM TO ASTM A992, Fy = 50 KSI.
\ PLATES, ANGLES, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI.
STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy = 46 KSI.
STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B, Fy = 35 KSI.
BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N. ANCHOR BOLTS SHALL CONFORM TO
ASTM A307.
ALL EXTERIOR EXPOSED STEEL SHALL BE HOT -DIP GALVANIZED OR OTHERWISE COATED PER ARCHITECTURAL
RECOMMENDATIONS.
CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC
MANUAL OF STEEL CONSTRUCTION,
WELDING
WELDING SHALL CONFORM TO AWS "STRUCTURAL WELDING CODE", LATEST EDITION. ALL WELDING SHALL BE
DONE WITH 70 KSI LOW HYDROGEN ELECTRODES. WHERE NOT CALLED OUT, MINIMUM FILLET WELD SIZE SHALL BE
PER TABLE 5.8 IN AWS D1.1, LATEST EDITION.
ALL WELDING SHALL BE DONE BY WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) CERTIFIED WELDERS.
GENERAL
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND
CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE
PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE
PROCEEDING.
CONTRACTOR TO SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER
OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL
PERMANENT SUPPORT AND STIFFENING ARE INSTALLED.
CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL
ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS
ONLY WILL NOT SATISFY THIS REQUIREMENT.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL
ENGINEER.
FOUNDATION, FLOOR, AND ROOF FRAMING PLAN NOTES:
1. EXTERIOR FOOTINGS SHALL BEAR A MIN OF V-6" BELOW ADJACENT GRADE.
2. FOOTINGS AND SLAB ON GRADE SHALL BEAR ON FIRM NATIVE SOIL OR COMPACTED STRUCTURAL FILL.
3. WHERE SLAB ON GRADE IS INDICATED, SLAB SHALL BE 4" THICK W/ 6x6-W1.4 x W1.4 WELDED WIRE FABRIC
REINFORCEMENT (CENTERED). SLAB SHALL BE POURED OVER A 8 MIL VAPOR BARRIER OVER 4" OF 5/8"
CRUSHED ROCK.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, WALL LOCATIONS, AND CONCRETE ROUGH OPENINGS WITH
ARCHITECTURAL DRAWINGS AND NOTIFY ALL PARTIES OF ANY DISCREPANCIES.
5. FLOOR SHEATHING SHALL BE 3/4" PI 48/24 WITH 10d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM
BOUNDARIES, PANEL EDGES AND SHEAR WALLS AND 10" OC AT INTERMEDIATE FRAMING.
6. ALL DIAPHRAGMS UNBLOCKED UNO.
7. UNLESS NOTED OTHERWISE, ALL BEAM -TO -BEAM CONNECTIONS SHALL BE SIMPSON HU OR HUC SERIES FACE
MOUNT HANGERS W/ MAX NAILING.
8. UNLESS NOTED OTHERWISE, ALL JOIST -TO -BEAM CONNECTIONS SHALL BE SIMPSON HU SERIES FACE MOUNT
HANGERS W/ MAX NAILING.
9. UNLESS NOTED OTHERWISE, ALL BEAM -TO -POST CONNECTIONS AT ISOLATED POSTS (I.E. NOT IN A STUD WALL)
SHALL BE SIMPSON CCQ OR ECCQ COLUMN CAPS.
10. STUD WALL FRAMING SHALL BE 2x HF STUDS @ 16" OC FOR ALL STUD WALLS SHOWN ON THE PLAN
11. ROOF SHEATHING SHALL BE 1/2" PI 40/20 WITH 8d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM
BOUNDARIES, PANEL EDGES, SHEAR WALLS, COLLECTOR TRUSSES, AND BLOCKING OR TRUSS BLOCKING
PANELS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC.
12. SOLID BLOCKING EQUAL TO COLUMN WIDTH AND DEPTH SHALL BE INSTALLED IN THE JOIST SPACE BELOW
ALL UPPER LEVEL COLUMNS.
NOTE:
RAISE STEM WALL AS REQ'D AT PERIMETER AREAS
WHERE NEEDED DUE TO GRADES.
5/8" ABS @ 4'-0" O.C.
(2) #4 CONT TOP
STUD WALL PER
PROVIDE BLOCK OUT
FRAMING PLAN NOTES
AT DOOR OPENINGS
SLAB ON GRADE AND
SHEATHING AND
SUBGRADE PER
NAILING PER PLAN
FOUNDATION PLAN
z
Q
#4 @ 12" OC EA WAY
PAVING OR FINISHED
CENTERED IN WALL
GRADE PER ARCH °�
N
DRAWINGS
a
X X
000 CPO 000
(:�p0.0 0 0 0
*0 o o� o e� Oo o ,O
OO Oro O° O
o0 0 °
o 00
z
O��o 0
a
oo
0 000000
0o0 0°0
zl
O
OO ° O
-
0
11
FOOTING DRAIN /
8"
m
cr_
u
PER TYP DETAIL /
/
ALT HOOK AS
1' 4"
SHOWN
(3)-#4 BOTTOM
TYPICAL STEM WALL DETAIL
SCALE: 1" = V-0"
4" 0 PERFORATED PVC PIPE PER
LOCAL CODES WITH 6" OF 1"
MINUS GRAVEL ALL AROUND,
WRAPPED IN NON -WOVEN
GEOTEXTILE FABRIC. SLOPE TO
DRAIN 1/8" PER 1'-0" MIN. TURN
DOWN PERFORATIONS AS SHOWN
a
O 0 0 0° O
o0 OOP 0 a
0000 000
O a a
000 o0
0 0 OO 4
O °O�
OO
0 O
/�/ -III-III-III=
1
LINE OF MAX EXCAVATION.
IF SOIL IS OVER EXCAVATED,
REPLACE WITH LEAN MIX
CONCRETE. FIRM BEARING SOIL OR
COMPACTED
STRUCTURAL FILL
1 TYPICAL FOOTING DRAIN
SCALE: 1" = V-0"
STAGGER NAILS ON EA SIDE
OF PANEL JOINT
. . . . . . . . . . . . . . . . . .
-Fl------ - - - - - - - - - - - - - - - - - - - - - -------r-1-----�I�
II II II II
II II II II II II III
I j I I I I I I I I i 1 I ICI
II II II (�
HEADER PER PLAN I j I I I I I I I I 11 I I I
I.1 I•I I'I I'I I'I 1.1 1 1.
•11 11 II I II II II II I 1
•I
I•I 1 I j 1 1 I 1 2x FRAMING AT11
CRIPPLE STUDS PER 1 1 1 1 1 1 I I 11 11 ADJOINING PANEL EDGES I I I
PLAN; DO NOT CUT 1 II 1 1.1 I•I I 1• I'I I I I I 1 1
AWAY MATERIAL FROM 1 I• 1 1 I I I' 1 1 I I I I I I 1 1 I I
CRIPPLE STUDS j 1 1 1 I I I •1 1 I I I I I I I I I I I
1 11 II I 1 I II II II II II•I
11.11 11 II I'1 1 II II II II 111
1 1 1 1 1 I I I •1 1 1 I I
II II II I
II II II
FULL -HEIGHT 1 I•I 1 I'
HOLDOWN CHORD 1 1 1 1 1 1 I I I •1 1 1 _ _J L_-_-__J L_ -_-__J L_-_-_
1 1 1 1 1 1 I I 1 1 1 1Mi 1 I•I 1 1 1 I I I' I I I ' -� r--' --' 7 r' --' ---1 r-' --'
1 1 1 1 1 1 I I I •1 11 1 1 11 11
1 1 1 1 I.1 I I I. 1 1•I 101 101 101
11.11 11 II 1 1 11 II II II
1 1 1 1 1 1 I I I •1 1 1 I I I I I I
1111 11 II I 1 11 II II II
11.11 11 II I'1 11 II II II
1 1 1 1 1 1 I I I •1 1 1 I I I I I I
1 I I 1 I.1 I•I I. 1 1•I I'I I'I I'I
1 I•I 1 1 1 I I I � � � I I I I I I
1 1 I I I I I I I I I
1 1 I I 1 1 I I
AB W/ SIMPSON BP
PL WASHER, TYP I•I 1 1 I.1 I I I I I I
101 101 101
II I••1 11 II II II
II I.I �i II II II
II I II II II
I I I •I A 1�1 I I I I I I
PT SILL PLATE I'I I' 1 11 I'I I'I 101
-- - J1-- I I I I I I
-1L------1L------L
II ^� II II I I I I I
I I I I I I I I
4 II II 11
II II II
-I I I -III- 5/8" AB @ 5'-0" A 11 H- I I I I
CONCRETE FOOTING
1/
OR P/T SLAB RIM BOARD �\
OR RI OCKING
NOTES:
1. REFER TO STRUCTURAL NOTES FOR
ADDITIONAL INFORMATION.
2. FOR SHEAR WALLS WHERE NO HOLDOWNS
ARE SPECIFIED THE FIRST AB SHALL BE
LOCATED NOT MORE THAN V-0" AND NOT
LESS THAN (7) BOLT DIAMETERS FROM END
OF WALL.
NOTE:
SUPPORTS AT SOLID
POSTS SIM
BEAM PER
SIMPSON LTP4 C
A35 FRAMII`
ANCHOR EACH S11
OF BEA
SOLID OR MULT
STUD COLUMN PER F,_
TYPICAL SHEAR WALL DETAIL
SCALE: 3/4" = V-0"
ADJACENT NAILS IN A
ROW ARE TO BE
DRIVEN FROM
OPPOSITE SIDES, TYP
FOR 2x4 STUDS, PROVIDE SINGLE
ROW OF NAILS STAGGERED EA SIDE
WITH 1 1/2" EDGE DISTANCE. FOR
2x6 STUDS, PROVIDE (2) ROWS OF
NAILS SPACED AT 2 1/2" W/ 1 1/2"
EDGE DISTANCE
9" OC MAX SPACING BETWEEN
ADJACENT NAILS IN A ROW
0.131"0 x 3" NAILS, TYP
(5) STUDS MAX TO
BE USED FOR
BUILT-UP COLUMNS
TYPICAL BUILT-UP STUD COLUMN DETAIL
SCALE: 1" = V-0"
BEAM WIDTH,
MIN UNO
PARALLEL TO STUD WALL
JOIST DIRECTION
PER PLAN
STUD WALL
TYPICAL FLUSH BEAM SUPPORT DETAILS
SOLID
STUD COLU,.,,.
SIMPSON A35 (ONLY
REQUIRED AT EXTERIOR
HEADERS GREATER
THAN G SPAN)
(6) 0.131"0 x 3" NAILS -
TYPICAL STUDS
NOTE:
WHERE CONCRETE WALL WITH
HT> 2'-6" EXISTS, ROD MAY SHEAR WALL PER
EXTEND 24" MIN INTO WALL W/ PLAN
NUT & WASHER AS SHOWN
COUNTERSINK ADDITIONAL
END STUD AS REQ'D HOLDOWN PER PLAN
THREADED ROD AS REQ'D
FOR HOLDOWN W/ NUT AND
WASHER AT BASE. EXTEND
ROD INTO FTG, TYP UNO
II
Nli
TOP OF FTG
I
a II
1
a 3 a 11 a G
a I 1 a
4
II a a
a
a a
a � �
mU
HOEDOWN DETAIL (NEW FOOTING)
SCALE: 1" = V-0"
�e1►1����Zel�►1e11� 1►[e
PANEL EDGE NAILING INTO
HOLDOWN CHORDS, TYP
INTERMEDIATE
NAILING @ 12" OC
SHEATHING PER PLAN NOTES
2-2x HOLDOWN CHORD.
REFER TO TYPICAL
BUILT-UP COLUMN
DETAIL
ADDITIONAL END STUD
IF REQUIRED TO
PROVIDE
COUNTERSINK FOR
HOLDOWN BOLTS
HOLDOWN ANCHORAGE
PER PLAN
SIMPSON CNW COUPLER 1/2" TO
NUT W/ SIZE TO MATCH SHEATHED EDGE
HOLDOWN ANCHORAGE
PANEL EDGE
NAILING
CONTINUE HOLDOWN CHORD
TO FOUNDATION
CONCRETE STEM WALL
CONCRETE FOOTING
TYP DOUBLE
TOP PLATE
BEAM OR HEADER PER
PLAN AND NOTES
NAILING PER TYP
BUILT-UP STUD
COLUMN DETAIL
LEI I
AT HOEDOWNS: PROVIDE FULL HT MIN (2) CRIPPLE STUDS UNO PER PLAN
HOLDOWN CHORDS PER HD SCHED.
OTHERWISE: (1) 2x FULL HT
TYPICAL HEADER DETAIL
SCALE: 1" = V-0"
BEAM PER PLAN
SIMPSON A35 EACH
`SIDE OF BEAM
i
cn
=
o�
;w
J
LL
I
a
C
JK/
.
PERPENDICULAR TO STUD WALL
FSTUD
WALL
ROOF SHEATHING AND NAILING PER
PLAN NOTES (ON THIS SHFI-1
2x RI
16d @ 6" 0.
SHEATHING AND
NAILING PER PLAN
NOTES
STUD WALL PER PLAN
SECTION
3/16" x 3" x 3"
PLATE WASHER
TYP
II,
II a
I
II „
II
SECTION A -A
SCALE: 1 1/2" = V-0"
COUNTERSINK ADDITIONAL
END STUD AS REQ'D
SOLID FILL JOIST
SPACE BELOW HD
CHORDS
SHEAR WALL PER
PLAN
1 13011Z91TITI►1aa.1»eU
ii
I I THREADED ROD AS REQ'D
THREADED ROD AS REQ'D I I PER PLAN. INSTALL
PER PLAN. INSTALL I I W/ HILTI HIT-HY 200 EPDXY
W/ HILTI HIT-HY 200 EPDXY I I
I
II a I
Il u a II
11 a.
d (�
dam: VERIFY 1/2"
a
dd d d �� a a AB@4'-0"
. a 4 . 1 (MIN)
d.
a d
d d 4 4
EXIST CONCRETE WALL
1 HOLDOWN DETAIL (EXIST FOOTING)
SCALE: 1" = V-0"
NOTE:
STAGGER SHEATHING AS
SHOWN. (IBC TABLE
2306.3.1, CASE 1
SHEATHIr
PANEL, T
CONTINUOUS
PANEL EDGES
PANEL EDGES
2x OR 3x BLOCKING ONLY
IF BLOCKED DIAPHRAGM
it rnri^rirn
TYPICAL FLOOR/ ROOF SHEATHING DETAIL
SCALE: NTS
EDGE NAILING PER PLAN
0.131"0 x 3"
NAILS @ 9" OC
(2) ROWS OF 0.131"0 x 3"
NAILS @ 9" OC
STUD WALL PER
FRAMING PLAN
NOTES, TYP
SHEATHING (OR GWB) AND
NAILING PER PLAN
EDGE NAILING PER PLAN
v
A. CORNER INTERSECTION B. 'T' INTERSECTION
TYPICAL WALL INTERSECTION DETAIL
SCALE: 1" = V-0"
2x6 STUD @ 2x4 CROSS WALL
2x8 STUD @ 2x6 CROSS WALL
EDGE NAILING PER PLAN
0.131"0 x 3"
NAILS @ 9" OC
STUD WALL PER FRAMING
PLAN NOTES, TYP
SHEATHING (OR GWB) AND
NAILING PER PLAN
CONCRETE p
WALL LINTEL PER
leLz
PLAN AT
4 HEAD OF
OPENING
1/4"0 x 3" CONCRETE
SCREWS @ 12" OC
NOTE:
SAWCUT DOOR OPENING
AND EXTEND LINTEL ANGLE
3" BEYOND EDGE OF
OPENING ON EACH SIDE.
STEEL LINTEL AT SAWCUT DOOR OPENING
Project Name:
4 1 13 R Improvements
Architect's Project Number:
1809
Project Address:
4 1 13 R Avenue
Anacortes, WA 96221
Owner:
Martin and Sarah Lee
Owner's Address:
PO Box 75G
Anacortes, WA 98221
Drawn:
3 1 October 2018
Revised:
30 November 202 I
Sheet Contents:
Structural Notes
Structural Details
G . G
WAS �cS�
;9L 3 �41
ONAL
130121
U
W
N
00
00
d\
x
�
U
d
�
0
z
O
U
�
F�
W
a
o
N
t�
Q In
� o
con
�
� o
O O1
�
O N
o
m �
F-
Vn
N
v / SCALE: 1" = V-0"
SCALE: 1" = V-0"
SCALE: 1 1/2" = V-0"
s I I
Architect's Project Number:
TREAD/RISER PER ARCH USE 1
1/8" PLYWOOD TREADS UNO
2x12 BLOCKING
1/2" AB @ 3'-0" OC OR PROVIDE
HILTI X-DNI (0.145"0) @ 12" OC.
EMBED MIN 2" INTO CONCRETE W/
STANDARD STEEL WASHER
TREATED 2x SILL PLATE -n
TYPICAL STAIR SECTIONS
SCALE: 1" = V-0"
NOTE:
AT CONDITION WHERE JOISTS ARE
PARALLEL TO STUD WALL, THE DTT1Z
TIES SHALL BE CONNECTED TO 2x
BLOCKING SECURED IN THE JOIST
BAY W/ (3) 10d TOE OR END NAILS
5/8" SPACERS
ATTACH JOIST TO CONT
LEDGER W/ SIMPSON
LUS SERIES HANGERS
DECKING
Partial Foundation Plan
1 5 10
SCALE IN FEET
2x12 NOTCHED
STRINGER
DO NOT OVERCUT NOTCHES BEAM PER PLAN
FOR TREAD/RISER
EXISTING WOOD
STUD WALL
2x BLOCKING ATTACHED TO
EXISTING 2x RIM OR 2x BLKG
BETWEEN JOISTS. SECURE EA END
W/ (3) 10d TOE OR END NAILS
SIMPSON DTT1Z TENSION
TIE @ 8'4" OC AND (1) @
EA END OF DECK
DECK JOIST PER PLAN J u
2x PT HF#2 LEDGER EXISTING JOISTS
ATTACHED TO RIM W/ (2) PER PLAN
5/8" 0 GALVANIZED THRU
BOLTS @ 12" OC. DO NOT EXISTING WOOD BEAM (WHERE
OVER -DRILL BOLT HOLES. IT OCCURS). SIM CONDITION HAS
A STUD OR CONCRETE WALL
BELOW THE FRAMING LEVEL
INSTEAD OF A BEAM
DECK CONNECTION TO HOUSE
SCALE: 1" = V-0"
1/4" CAP PL, TYP
EA COL
STEEL BEAM PER
PLAN (ON BOTH
SIDES ONLY WHERE
APPLICABLE)
3„ 11/2"
N
N STEEL BEAM
PER PLAN
♦ -
SHEAR PL 3/16 x 4 1/2 x 0'-6"
W/ (2) 3/4"0 A325-N BOLTS
3/16
COL PER PLAN
BEAM -TO -COLUMN CONNECTION
2x12 STRINGER
2x6 SISTERED TO SIDE
OF 2x12 W/ (2) ROWS JOIST PER
OF 10d NAILS PLAN
STAGGERED @ 6" OC AS
SHOWN •
HUC28-2 W/
FULL NAILING
3" 11/2"
STEEL COLUMN
I
I
PER PLAN
5/8" THREADED RODS I I
EMBEDDED INTO I
10" x 10"
FOOTING AS SHOWN
CONCRETE PLINTH
I
W/#3 TIES @ 3" OC
3/4" LEVELING I
GROUT I
FINISHED GRADE
N I I
OR CONCRETE
SLAB PER PLAN
(3) #4 BOT BARS,
II II
EACH WAY
II II
II II
� II II
_ c[
m U
2'-0"
DECK COLUMN FOOTING
SCALE: 1" = V-0"
N
N STEEL BEAM
PER PLAN
I ♦ _
I ♦ M
I
SHEAR PL 3/16 x 4 1/2 x 0'-6"
W/ (2) 3/4"0 A325-N BOLTS
COPE FLANGE AS REQ'D
BEAM -TO -BEAM CONNECTION
STEEL BEAM SHEAR PLATE CONNECTIONS
SCALE: 1" = V-0"
3/8" STIFF PL EA
SIDE Cr'*'-
-
9"
10/
♦ � 3/16
♦ ♦ BASE PL 5/8 x 9 x
0'-9" W/ (4) 5/8"
N THREADED RODS
STEEL BASE PLATE
STEEL BEAM CONNECTION
SCALE: 1" = V-0"
TYP
F-11 Al»all »e1►
5 1/4 x 0'-10"
/8" 0 BOLTS
UMN
V
FLAT
DECKING
ROOF SHEATHING AND
NAILING PER PLAN NOTES
(ON THIS SHEET)
2xRIM -
16d @ 6" O.C. -
SHEATHING AND
NAILING PER PLAN
NOTES
STUD WALL PER PLAN
SECTION
SCALE: 1" = V-0"
HSS4x4x3/16,
CONN PER DET 6
CONT 2X6 DECK JOISTS
PLATES PER PLAN
ROOF JOISTS
PER PLAN
DECK RAILING
PER MFR
CONT RIM, AT
TO EACH JOIST W/ (3)
13d END NAILS
FLAT
2x BLOCKING AT RAIL
DECKING
POST LOCATIONS ONLY,
DECK JOISTS
ATTACHED TO EACH JOIST
PER PLAN
W/ (3) 10d END NAILS
)
A3
A35 CLIP AT
JOIST AT
r
RAIL POST
2x BLI<G
10d TOENAILS
@ 8" OC
2x NAILER RIPPED TO WIDTH
OF BEAM W/ 1/2"0
BEAM PER
CARRIAGE BOLTS @ 24" OC
PLAN
STAGGERED EACH SIDE OF
WEB (CONTRACTOR HAS
OPTION TO COUNTERSINK)
DECK EDGE DETAIL
SCALE: 1" = V-0"
CONNECTION
PER DET 6
HSS4x4x3/16,
CONN PER DET 7
L
i cc
C7 w
0CIO a
11
3 ccS1.
a a
aF
HSS4x4x3/16,
CONN PER DET 6 IPT 2x8 HF
#2 @ 16"
S I M 4143
Ln S2.1
(D w
Q m m
1 a
x O
cc
W8x18 (GR 50)
DROP BEAM A
PT 2x8HF HSS4x4x3/16,
#2 @ 16" Q CONN PER DET 6
m a
k O
m cc
o
W8x1�(GR
DROP-
DBL JOIST
15/32" PLYWOOD SHEATHING ONE
FACE OF WALL WITH 8d @ 6" OC PANEL
EDGE NAILING. REFER TO DETAILS ON
S1.1. AT BASE OF WALL PROVIDE 16d @
6 OC SILL PLATE NAILING INTO
RIM/BLOCKING & CONNECT
RIM/BLOCKING TO MUD SILL W/ A35
CLIPS @ 16" OC. AT TOP OF WALL
PROVIDE A35 CLIPS @ 16" OC BETWEEN
DBL TOP PLATE & RIM/BLOCKING.
Sir
W/
STE
HSS4x4x3/16,
CONN PER DET 7 5
2x RIM
-----------
W8x18 (GR 50)
DROP BEAM
L-
N
00
o N @ 2
C a :13- S2.1 1
46 H F #2 r
1
3
2
2x8 H F #2
@ 24"
3
y
6x6 DF
POST
5 1/8" x 12" 24F-V4 GLB
■
DROP BEAM L
EXISTING
2x10 JOISTS
(2)-2x,
TYP UNO
■
2x6 HF
@16"_
■
C
HSS4x4x3/16
W 8x18 (GR 50)
DROP BEAM
7
11 S2
00 iD
N U_ _
JM 00
N N @j
N
a a �
S I M 3
52.1
VERIFY
VERIFY VERIFY (2)-2x
■
46 HDR 4x6 HDR
6x6 DF
POST
(2)-2x
EACH
END
4x10 DF #2
2x6 HF
@ 16"4(4)
x 0 DF #2
• 2x
4x6 EA
H F#2 101
L5 x 3 x 1/4"
LINTEL PER
DETAIL 12/S1.1
2x6 HF (2)-2x,
' @ 16TYP UNO
H
(n
O
J
m
0
ERIFY
4x12 HDR
LEGEND
® PROPOSED SHEAR WALL
OVER EXTENTS SHOWN
Y PROPOSED FLOOR IN -FILL
FRAMING W/ 3/4"
PLYWOOD OVERLAY
NOTES
OAT NEW EXTERIOR WALLS, INSTALL 15/32" PLYWOOD
SHEATHING EXTERIOR FACE OF WALL WITH 8d @ 6" OC
PANEL EDGE NAILING. REFER TO DETAILS ON S1.1 FOR
INSTALLATION & CONNECTION INFORMATION AT BASE AND
TOP OF WALLS.
OPROVIDE (2) END STUDS & SIMPSON HDU2 HOLD-DOWN W/
5/8" THREADED ROD INTO STEM WALL BELOW. REFER TO
DETAILS ON S1.1.
O(2)-2x FULL HEIGHT+ (1)-2x CRIPPLE. INSTALL SIMPSON HDU2
HOLD-DOWN W/ 5/8" THREADED ROD INTO STEM WALL
BELOW. REFER TO DETAILS ON S1.1.
EXISTING GARAGE HEADER
I SISTER (2) 1 3/4" x 11 7/8"
r ant rind^ inrrni�n I VI Tn FACH CInF nF
IN -FILL EXISTING STAIR
OPENING. EXTEND
FRAMING TO CENTRAL
BEARING WALL AS SHOWN
(3) 1 3/4" x 9 1/4" LVL
(ALIGN BELOW UPPER
LEVEL COLUMN)
LANDING X— ALL SLOPED
BEAMS STRINGERS (2)-2x PER
(2)-2x10 STAIR DETAILS, TYP Main Floor Framing Plan
HF#2, TYP
NORTh
I 5 10
SCALE IN FEET
EXISTING
2x10 JOISTS
(2) 2x
STUDS
WALL LEGEND
® PROPOSED SHEAR WALL
OVER EXTENTS SHOWN
Project Name:
4 1 13 R Improvements
Architect's Project Number:
1809
Project Address:
4 1 13 R Avenue
Anacortes, WA 96221
Owner:
Martin and Sarah Lee
Owner's Address:
PO Box 75G
Anacortes, WA 98221
Drawn:
3 1 October 2018
Revised:
30 November 202 1
Sheet Contents:
Foundation Plan
Framing Plans
Structural Detail
GAS' WAR
�F
E7 o
39553 11
S L
0NAL
11 �0/
21
U
W
N
00
a,
U
d
�
z
O
0
U
H
W
a
N
o
N
Q
Q In
con
� o
� o
�
�
O O1
O N
F-
� O
m �
�
N
S2.1