Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0931 3949 Rock Ridge Parkway (6)GNl y O� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Residential Building Permit Application Submittal Packet New Single Family Residences (SFR) Duplexes Additions and Remodels (SFR & Duplex) Accessory Dwelling Units Manufactured Homes Residential decks and retaining walls FORM BP-1: APPLICATION 1. PROPERTY INFORMATION Project Address (Street, Suite #): Assessor Parcel Number: 3949 ROCK RIDGE PARKWAY P134318 Subdivision/Lot #: Zoning Designation: Lot area (size): LOT 7, PLAT OF ROCK R2 10,095 sq. ft. RIDGE SOUTH PHASE 5, 2. TYPE OF PROJECT 115 New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) ❑ New Duplex ❑ Attached to Primary Unit ❑ Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport, or accessory building ❑ Retaining wall or duplex (new/repair) ❑ Other: Project Summary: New two story w/ daylight basement for a total of 3 floors, 4,009 sf, 5 bedroom 4 bath single family residence with attached 725 sf garage. Project Valuation: $ 902,025 3. PROPERTY OWNER INFORMATION NAME: WEISBERG JOSHUA Phone: PRICE JENNIFER 425-301-2223 Address (Street, City, State, Zip): Email Address: 11733 174TH PL NE, REDMOND, WA 98052 Josh Weisberg <josh@joshpix.com> Jennifer Price<jen98052@outlook.com> 4. CONTRACTOR INFORMATION Name:* Strandberg Construction Phone: (360) 293-7431 Contractor's Business Licenses State License #: City License #: *All Contractors & Subcontractors must have a valid City STRANC1020CC 601839950 Expiration Date: Expiration Date: of Anacortes business license prior to doing work in the City. 02/02/22 12/31 /21 Address (Street, City, State, Zip): Email Address: 2018 R AVE jasons@strandbergconstruction.com Anacortes, WA 98221 IN IN IN Page 1 of 19 Res. Building Permit Application Submittal Checklist Updated April 20, 2021 GNl y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 � CpSz 5. CONTACT PERSON Select one person the city will contact for anything ®Applicant El Property Owner ®Contractor related to this project: ❑ Other (list below) Name: Jason Sterling Phone: (360) 293-7431 Address (Street, City, State, Zip): Email Address: 2018 R AVE jasons@strandbergconstruction.com Anacortes, WA 98221 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write "no lenders" on the Name Line below. Name: Phone: Address (Street, City, State, Zip): Email Address: 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: ES I understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technically complete and sufficient for staff review. ES I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. ES I understand and acknowledge that I could be responsible for providing as -built drawings (on paper or electronically) as part of the project's certificate of occupancy process. ES I understand and acknowledge that Special Inspections could be required as part of my project, and if needed I will be required to pay for the cost of these inspections. ES I understand and acknowledge that financial securities could be required as part of the work I am completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. ES I understand that if permits are reviewed concurrently such as design review, site plan, traffic concurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 2 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. Signature Jason Sterling Printed Name 11/11/2021 Date Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 3 of 19 G1T y O� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 SUBMITTAL CHECKLIST M CL �, a Residential Building Permit C y f0 y Submittal Requirement Checklist L. W �, o �a Y LL L N o 0 .S — �— O c � 3 cu t� C -0 C v Q v See pages 2-3 of this handout for information about each 3 u v O Q V submittal item listed below. Z v U Q 0�� = N i 0 x Residential Building Permit Application Form X X X X X (FORM BP-1—attached) Structure & Site Information Form X X X X X (FORM BP-2 — attached) Mechanical & Plumbing Fixtures Form X X X (FORM BP-3 — attached) Architectural Plans X X X X X (requirements listed on FORM BP-4 - attached) Stormwater Management Minimum Requirements Determination X X X X (FORM BP-5, attached) Stormwater Site Plan X X X X Site Plan & Landscape Plans X X X X X (requirements listed on Form BP-6) Structural Plans & Calculations X X X X X Energy Code Plans & Forms X X Manufacturer's Specifications/Cut Sheets X Copy of recorded survey X X X X Technical Reports X X X X Other Required Permits X X X X X ADU Affidavit of Owner Occupancy (signed) X Submittal Information Fees Send applications in PDF format with a file and message Once we receive your application, we will size no greater than 30 MB. Please review our Electronic contact you about payment of the Submittal Guidelines for more information. An email required deposit, if any. with a link to a file share site (Dropbox, Google Drive, OneDrive, etc.) is acceptable. Permit fees are paid prior to building permit issuance. Email: buildingpermit@cityofanacortes.org Incomplete applications will not be processed. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 4 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 �.4 coR Additional details on certain submittal items is provided below to ensure Applicants are fully aware what City staff will be looking for when an application is submitted to the City. FORMS AND PLANS • FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION FORM. Provides key information about your project, including type of permit you are applying for, and property owner, contractor, and contact information. • FORM BP-2: STRUCTURE AND SITE INFORMATION FORM. Provides key information about the proposed structure, including height, floor areas, fire protection proposed, and asks questions about site characteristics that are used to determine whether your project requires any other information or additional permit applications to be submitted. • FORM BP-3: PLUMBING AND MECHANICAL INFORMATION. Form BP-3 provides space for you to fill in fixture information for plumbing and mechanical appliances and equipment that are included as part of your project. • FORM BP-4: ARCHITECTURAL PLAN REQUIREMENTS. Form BP-4 contains a list of all the items required to be shown on Architectural Plans. • FORM BP-5: STORMWATER MANAGEMENT DETERMINATION FORM. Most development within the City of Anacortes that involves disruption of soils, or construction of buildings, streets, parking lots, etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed (grading, vegetation removal), or the amount of hard surface that is created or replaced on a site (building footprint, concrete, asphalt or gravel parking, sidewalk, etc.). Form BP-5 assists you in determining the level of stormwater review (applicable Minimum Requirements) required for your project. STORMWATER SITE PLAN. The Stormwater Site Plan is the comprehensive report containing all of the technical information and analysis necessary for regulatory agencies to evaluate your project for compliance with stormwater requirements. The level of stormwater review and contents of the Stormwater Site Plan will vary with the type and size of the project, and individual site characteristics. Use Form BP-5 to determine the level of stormwater review and then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Engineering Department Forms website and provide required submittal items/plans. • FORM BP-6: SITE PLANS & LANDSCAPE PLANS. Form BP-6 contains a list of all the items required to be shown on Site and Landscape Plans. STRUCTURAL PLANS: Plans prepared and stamped by a State of Washington licensed professional structural engineer drawn at a scale approved by the Building Official clearly indicating the information required by the "Permits" section of the currently adopted International Building Code and Chapter 19.27 RCW (State Building Code Act, Statewide amendments), and City submittal forms including: structural members labeled as to size and spacing as well as bracing, blocking, bridging, special connectors, and anchor bolts; cross-section details, as needed, to show typical foundation, floor, wall, ceiling and roof construction; insulation of walls, floors and roof/ceiling; and details of stairs, fireplaces and special construction, if any. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 5 of 19 G1T y O� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 • STRUCTURAL CALCULATIONS: An analysis of loads, materials, etc., prepared and stamped by a State of Washington licensed professional structural engineer. • ENERGY CODE FORMS: The standard Washington State Energy Office form requesting the information required under Chapter 51-11 WAC detailing building components used to comply with the State Residential or Nonresidential Energy Code, as applicable. • MANUFACTURER'S SPECIFICATIONS/CUT SHEETS: A document that summarized the performance and other technical characteristics of a product, machine, component, material, or subsystem (e.g., a power supply) in sufficient detail that allows the City to determine the product will be incompliance with applicable codes. • COPY OF RECORDED SURVEY. A survey of your property is needed so that conformance with minimum setback requirements and other development standards can been confirmed and verified on site by the inspectors. Property markers must be visible on your property. If they are not at the time an inspection is requested, you may need to have a new survey completed. OTHER SUBMITTALS DETERMINED ON A CASE -BY -CASE BASIS TECHNICAL REPORTS Following is a list of technical reports that will be required to be submitted to the City when certain circumstances exist on or near a site an Applicant is planning on making improvements to. The general triggers for each of the listed technical reports I provided below: A. CRITICAL AREAS REPORTS: In general, Critical Area reports are required when wetlands and/or streams are located on or near a site. Critical area mitigation plans may also be required, depending on the project proposal. See Anacortes Municipal Code Ch. 17.70 for additional information. B. GEOTECHNICAL REPORT: In general, Geotechnical Reports are required when work is proposed on or near slopes in excess of 15% and/or known landslide hazard areas. See Anacortes Municipal Code Ch. 17.70 for additional information. OTHER PERMITS DETERMINED ON A CASE -BY -CASE BASIS OTHER FORMS Following is a list of other permits that could be required in certain circumstances. The general triggers for each of the listed permits is provided below. A. FILL AND GRADE PERMIT: Grading (importing, exporting, and/or moving material on a site) of more than 50 cubic yards and/or if grading modifies the existing flow of stormwater or groundwater. B. RIGHT-OF-WAY PERMIT: A right-of-way permit is required anytime the public right-of-way is disturbed or obstructed in any way by private development or the general public. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 6 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Page left blank intentionally. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 7 of 19 e° PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 • • AND • ' • 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3949 ROCK RIDGE PARKWAY Anacortes, WA PARCEL NUMBER(S) P134318 2. DETAILED PROPOSED STRUCTURE INFORMATION Complete the following information as it relates to your project. Mark items that are not applicable with Structure height:34'-9" AREA SQUARE FOOTAGE OCCUPANCY GROUP CONSTRUCTION TYPE OCCUPANT LOAD 15t Floor: 1,353 SQ.FT. V 2nd Floor: 1,573 SQ.FT. V 3rd Floor: Basement: 1,083 SQ.FT. V Garage: 725 SQ.FT. V Total deck: 276 SQ.FT. V Total porch: 195 SQ.FT. V Total Balc: 555 SQ.FT V Store/UTL.: 161 SQ.FT V Other: 3. QUESTIONS ABOUT THE PROPOSED STRUCTURE Is a fire sprinkler system being installed? YES ❑ NO Is a monitored fire alarm being installed? ❑ YES C NO Are retaining wall(s) being built? ® YES ❑ NO Are structural plans required? ® YES ❑ NO 4. PROJECT SITE INFORMATION A. Is work within the City's right-of-way proposed? If yes, you will be required to submit a right-of-way permit application. If you have already submitted a ROW permit, list the permit number here: ❑ YES ® NO B. Is the property located in a flood zone? If yes, list the flood zone designation: ❑ YES ® NO C. Are there slopes in excess of 15% on or abutting the site? If yes, a geotechnical report will likely need to be submitted. ® YES ❑ N0 Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 8 of 19 e° PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 f Phone: (360) 293-1901 D. Are there critical areas or buffers on or abutting (within 300-feet of) the ❑ YES lig NO project site? If yes, a critical areas report will likely need to be submitted. E. Is the lot less than 5,000 sq. ft. in area? ❑ YES ® NO If yes, your site and building will need to comply with the standards in AMC 19.43.010.C. F. Is your project involving an accessory dwelling unit? ❑ YES ® NO If yes, your site and building will need to comply with the standards in AMC 19.47. G. Will more than 2-acres be cleared and/or more than 5,000 board feet ❑ YES ® NO (about 1 log truck load) of timber be harvested? If so you may need to obtain a forest practices permit from DNR. H. Is this project subject to the SEPA process? If yes, you will be required to ❑ YES ® NO submit a SEPA checklist. If you have already completed the SEPA process, list the permit number here: 5. REQUIRED SIGNATURE I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. 11/11/2021 Signature Date Jason Sterling Printed Name Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 9 of 19 e° PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 MECHANICAL Equipment Type: Appliance/Equipment Information (new and relocated): Total #: Furnace: Gas #: Elec #: BTU: Other #: Wall Heater: Gas #: Elec #: Other: #: Location(s): Gas Water #:1 Location(s): Utility 1 Heat Pump: Elec #: Other #: Capacity: Air Conditioning: Elec #: Other #: Capacity: Radiant /Hydronic Gas #A Elec #: Other: #: Location(s): 1 Exhaust Fans: Bath #:5 Laundry #:1 Other: 6 Range Hood: #:1 Location(s): Kitchen 1 Fireplace: Gas #:1 Elec #: Other: #: Location(s): 1 Clothes Dryer & Duct: Gas #: Elec #:1 Other: #: Location(s): 1 Stove/Range/Oven: Gas #:1 Elec #: Other: #: Location(s): 1 Gas Piping/ Outlet(s): #:1 Location(s): Covered Balcony 1 Boiler Gas #A Elec #: BTUs: Location(s): 1 Other: #: Location(s): TOTAL MECHANICAL OUTLETS:14 PLUMBING Fixture Type (new and relocated): Total #: Fixture Type (new and relocated): Total #: Water Closet (Toilet): 4 Refrigerator water supply (for water/ice 1 Kitchen Sink: 2 Pressure Reduction Valve/Pressure Regulator: 1 Utility Sink: 2 Water Service Line: 1 Tub: 2 Water Piping: 1 Hand Sink: 7 Clothes Washer: 1 Shower: 2 Electric Water Heater: Tank -less? Yes ❑ Dishwasher: 1 Backflow Prevention Assembly: 1 Hose Bib: 5 Other: TOTAL PLUMBING FIXTURES:31 Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 10 of 19 e° PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 O. BP-4: ARCHITECTURAL PLAN REQUIREMENTS 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3949 ROCK RIDGE PARKWAY Anacortes, WA PARCEL P134318 NUMBER(S) 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant architectural plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11" x 17" and drawn in an architectural scale. • Architectural plans for structures 4,000 square feet or larger are required to be prepared and stamped by an architect licensed in the State of Washington. • Structural plans must be stamped by a structural engineer licensed in the state of Washington. 3. REQUIREMENTS FOR ALL ARCHITECTURAL PLANS COMPLETE REQUIREMENTS PAGE # ON ? YOUR PLANS Yes Cover (or 15T page) must include: C1 • Site address • Parcel number • Lot number (if applicable) • Lot size • Lot coverage • % impervious surface coverage Yes Floor plans with existing (if applicable) and proposed building layout with squareA3,A5,A7 footages and with the use of each room/area labeled. Yes Window and door sizes labeled and window ventilation area. Commercial, A3,A5,A7 Multi -Family, and Mixed -Use Structures must also include door and window schedules. Yes Plumbing, duct, and electrical layout. Penetration protection must be shown. A3,A5,A7 Yes Opening headers, size, and material. A3,A5,A7 Yes Cross section details, showing typical foundation, floor, wall, ceiling and roof construction and insulation. Yes Structural members labeled as to size and spacing as well as bracing, blocking, AO-S3 bridging, special connectors, and anchor bolts. Yes Details documenting energy code compliance. Cover, AO Yes Exterior building elevations demonstrating compliance with applicable structure Al 1-Al2 type design standards (small lot, duplex, or ADU) and maximum building height Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 11 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Yes Building height (see AMC 19.42.120 for measurement methods, exceptions and modifications). A 11-Al2 0 Show a line representing, and label the elevations of, the existing natural topography at the foundation at the front of the building. 0 For corner lots and lots that slope downhill from the property line at the front of the building: Show a line representing, and label the elevations at the center of all exterior walls of the building. 0 For ADUs only, include elevations demonstrating compliance with the height/setback plane (see AMC 19.47.030(C)(6)). Yes Special details as needed (i.e., stairs, fireplaces, special construction). 0-S3 Yes Insulation and insulation values of walls, slab, floors, and roof/ceiling. A9-A10 Yes Existing and proposed grades with slope of lot shown. C1 Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 12 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 •STORMWATER MANAGEMENT MINIMUM REQUIREMENTs DETERMINATION 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3949 ROCK RIDGE PARKWAY Anacortes, WA PARCEL NUMBER(S) P134318 2. GENERAL INFORMATION Most development within the City of Anacortes that involves disruption of soils, or construction of buildings, streets, parking lots, etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed (grading, vegetation removal), or the amount of hard surface that is created or replaced on a site (building footprint, concrete, asphalt or gravel parking, sidewalk, etc.) This form is largely targeted for small projects and single family residences. For larger projects and more information please refer to the Anacortes Municipal Code (Chapter 19.76 Stormwater Management) and the latest Washington State Department of Ecology Stormwater Management Manual for Western Washington (Ecology Manual). 3. HARD SURFACE AREA CALCULATION Please calculate your project's hard surface amount; guidance is provided on the next page of this document. Use your project's total hard surface calculation to follow the flow chart(s) in this packet and determine the level of stormwater management required for you project. When determining your permit level or if stormwater thresholds are met or exceeded the entire project must be considered. A project is that portion of a property, properties, or right of way subject to land disturbing activities, new hard surfaces and replaced hard surfaces. The hard surface on your property will determine the storm water utility fees and the stormwater general facility charge. All new or replaced hard surfaces should be accounted for. Below are excerpts from the Anacortes Municipal Code and Ecology Manual that may assist you in preparing this information. "Hard surface area" means an impervious surface, a permeable pavement, or a vegetated roof. "Impervious surface" means a non -vegetated surface area which either prevents or retards the entry of water into the soil mantle as under natural conditions prior to development. A non -vegetated surface area which causes water to run off the surface in greater quantities or at an increased rate of flow from the flow present under natural conditions prior to development. "Replaced impervious surface" means, for structures, the removal and replacement of impervious surfaces down to the foundation. For other impervious surfaces, the removal down to bare soil or base course and replacement. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 13 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Land disturbance Description Total (SF) 10,000 SF +/- Total Area of Land disturbing activity 3,432.05 +/- Total area converted from vegetation to lawn or landscaped areas Hard surface area calculation Description Existing Removed (SF) (SF) Proposed Proposed Replaced New Non Pollution Generating Hard 2,819 sf Surface Area (Sidewalks, paths, patios, etc.) Pollution Generating Hard Surface Area (Driveways, parking areas, etc.) Total Hard Surface 10,095 sf Site Size ,006 SF 25 sf Existing impervious surface Note: site is mostly rock and already coverage % N/A % impervious. (sq. ft. hard surface / site size) Use the information in the above table to navigate the flow chart(s) on the next page and determine the applicable stormwater management minimum requirements for your project. Then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Engineering Department Forms website and provide required submittal items/plans. Check applicable box Minimum Requirements Determination Minimum Requirements #1-9. Minimum Requirements #1-5. ® Minimum Requirement #2. Res. Building Permit Application Submittal Checklist Page 14 of 19 Updated April 20, 2021 G1T y O� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 -1co Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 FLOW CHART FOR DETERMINING REQUIREMENTS FOR NEW DEVELOPMENT Start Here Does the site have 35% or more of existing impervious coverage? No Does the project result in 5,000 square feet, or greater, of new plus replaced hard surface area? Yes See Redevelopment Minimum Requirements and Flow Chart (Figure 1-2.4.2). Does the project convert Y4 acres or more of vegetation to lawn or landscaped areas, or No convert 2.5 acres or more of native vegetation to pasture? No Yes Yes Does the project result in 2,000 IF square feet, or greater, of new plus All Minimum Requirements replaced hard surface area? apply to the new and replaced hard surfaces and converted Yes NO vegetation areas. IF Does the project have land Minimum Requirements #1 disturbing activities of 7,000 through #5 apply to the new Yes square feet or greater? and replaced hard surfaces and the land disturbed. IF No Minimum Requirement#2 applies. Figure 1-2.4.1 Flow Chart for Determining Requirements for New Development DEPARTMENT OF Revised June2015 ECOLOGY Please see htfp /Arww.ecy.wa gov/copyrlght.hfmlfor copyright notice including permissions, State of Washington limitation of liability, and disclaimer, Res. Building Permit Application Submittal Checklist Updated October 10, 2019 Page 14 of 18 G1T y O� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 '_17,1co Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 FLOW CHART FOR DETERMINING REQUIREMENTS FOR REDEVELOPMENT Does the project result in 2,000 square feet, or more, of new plus replaced hard surface area? OR Does the land disturbing activity total 7,000 square feet or greater? Yes �No Minimum Requirements #1 through #5 apply to the new and replaced hard Minimum Requirement #2 applies. surfaces and the land disturbed. Next Question Does the project add 5,000 square feet or more of new hard surfaces? OR Convert Y4 acres or more of vegetation to lawn or landscaped areas? OR Convert 2.5 acres or more of native vegetation to pasture? Yes No All Minimum Requirements apply Next Question Is this a road to the new hard surfaces and the related project? No converted vegetation areas. Yes Does the project add 5,000 square feet or more of new hard surfaces? Yes No Is the total of new plus replaced hard surfaces Do the new hard 5,000 square feet or more, surfaces add 50% or No No additional No AND more to the existing does the value of the proposed improvements requirements. hard surfaces within - including interior improvements - exceed 50% of the assessed value (or replacement All minimum req. are taken care of by value) of the existing site improvements? common plan of development. Only minimum req. #2 is needed. ly to the new and replaced Yes ed vegetation areas. Figure 1-2.4.2 Flow Chart for Determining Requirements for Redevelopment DEPARTMENT OF Revised June2015 ECOLOGY please see htfp:/Mww.ecy.wa.gov/copyright.htmI for copyright notice including permissions, State of Washington limitation of liability, and disclaimer_ Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 15 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 • ' • REQUIREMENTS 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3949 ROCK RIDGE PARKWAY Anacortes, WA PARCEL P134318 NUMBER(S) 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant site plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11" x 17" and drawn in an engineering or architectural scale. 3. INFORMATION REQUIRED ON ALL SITE PLANS COMPLETE? REQUIREMENTS PAGE # ON YOUR PLANS Yes 1,C1 Cover sheet must contain all of the following: • Vicinity Map • Name of the project • Name, address, and telephone number of owner and agent(s) • Name, address, and telephone number of Applicant (if different from the owner) • Zoning designation of the site • Area, in square feet and acreage, of the project site • Reference to the Building Code used • Proposed use • Occupancy group • Construction type • Square footage and height of each individual building • Percent lot coverage • Percent impervious surfaces Yes Scale and North Arrow C1 Property features: Yes Location, identification, and dimensions of all property lines and C1 easements. All easements shown on the title report, Record of Survey, or plat must be dimensioned and shown. Yes Location and dimensions of existing critical areas (wetlands, streams, C1 steep slopes) and their associated buffers. Yes Location of Ordinary High Water Mark and shoreline jurisdiction limits NA (if adjacent to a shoreline). Yes Existing and proposed contours and site elevations (i.e. finished C1 grades) at 5-foot minimum increments. The horizontal and vertical control datum must be clearly shown. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 16 of 19 G1T y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Structures: Yes Location, identification, dimensions and size of all existing and C1 proposed buildings and other structures. Yes Location of existing and proposed retaining walls, rockeries, and C1 Yes Location, identification, and dimensions of all setbacks. C1 Yes Show proposed projections into required setbacks, including C1 dimensions (see AMC 19.44.140) Utilities & Easements: Yes Location and dimensions of existing and proposed stormwater, C1 sanitary sewer, potable water, and fiber lines/facilities. All wells and septic systems located on or near the project site must also be identified. Yes Location of all existing and proposed fire hydrants within 300 feet of C1 the boundary of the project site. Yes Location and dimensions of existing and proposed freestanding C1 lighting fixtures, utility junction boxes, public utility transformers. Stormwater Yes Proposed Temporary Erosion and Sediment Control Measures, if not C1 located on other plans. Yes Proposed permanent stormwater management BMPs. C1 Access, Circulation & Parking Yes Location, identification, and dimensions of all existing and proposed C1 on -site and adjacent streets and alleys, including the location and dimensions of all existing and proposed curbs, gutters, sidewalks, median islands, and street trees. Yes Show existing and proposed vehicular access to the site, including the C1 size and location of driveways and curb cuts. Yes Show existing and proposed parking spaces, including surface materialCl and dimensions of spaces. Open Space (ADUs, Small Lots, and Duplexes) Yes Show calculations, location, dimensions and provided square footage NA of required open space area per AMC 19.43.010.C, E, or AMC 19.47, as applicable. Landscaping Yes Show the location and design of landscape areas to be preserved and C1 planted, and a plant list to include the location, number, size and type of plant material by botanical and common name. Yes Location of irrigation system if a permanent or temporary system is TBD proposed. Yes Show the location of existing trees to be retained in conformance C1 with AMC 16.50, and tree protection measures to be implemented, when applicable. Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 17 of 19 GNl y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Yes Provide a maintenance plan for any infiltration -based stormwater C1 best management practices (BMPs) built as part of the landscaping design, including the specifications and maintenance procedures of any soil amendments. Yes Show new trees to be planted and tree unit credit calculations, in C1 conformance with AMC 16.50 Tree preservation, when applicable The following table, with project specific information filled in, must be pla on the site plan: Required Landscaping For Example Calculations Site Area 7,500 sq. ft. % of site area to be landscaped (per 20% - R2A zone AMC Tables 19.42.020-.030) 1,500 sq. ft. required 1,850 sq. ft. provided Compliance with AMC Ch. 16.50 Tree unit credits required: Tree Preservation. • 8 tree units required Tree unit credits retained: • 2 trees 6" dbh = 4 tree unit credits retained Tree unit credits provided: • 2 new deciduous trees (min. 2" caliper @ 6" above ground) • 2 new evergreen trees (8' in height) Number of required street trees 1 per 30' of frontage 60 lineal feet of frontage = 3 street trees Res. Building Permit Application Submittal Checklist Updated April 20, 2021 Page 18 of 19