Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0163 3929 Rock Ridge Parkway (8)3929 Rockridge Parkway (#741434) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Project Details Name 3929 Rockridge Parkway Date 03/02/2021 Location 3929 Rockridge Parkway, Anacortes, WA 98221 Total modules 26 Module Hanwha Q.Cells: Q.PEAK DUO BLK-G6+ 335 (32mm) Total watts 8,710 Dimensions 68.5" x 40.55" x 1.26" (1740.0mm x 1030.Omm x 32.Omm) Attachments 32 ASCE 7-10 System Weight Load Assumptions Total system weight 1,332.8 Ibs Wind exposure B Weight/attachment 41.6 Ibs Wind speed 110 mph Racking weight 191.9 Ibs Ground snow load 15 psf Distributed weight 2.6 psf Attachment spacing portrait 6.0' Roof Information Roof material Metal Building height 30 ft Roof attachment L-Foot Only Roof slope 9 ° Attachment hardware Square Risk category II Span Details XR100 - Portrait Reaction Forces XR100 - Portrait Zone Down Uplift Lateral Zone Max span Max cantilever (Ibs) (Ibs) (Ibs) 1 8' 5" 3' 4" 1 354 135 54 2 8' 5" 3' 4" 2 354 281 54 3 8' 1" 3' 3" 3 354 450 54 Last updated by Libby Chartier on 03/02/21 12:52 PM Page 1 of 4 3929 Rockridge Parkway (#741434) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section 1 Definition Roof Section Weights 26 modules Total weight: 1,332.8 Ibs Portrait orientation Weight/attachment: 41.6 Ibs Graphical entry Total Area: 509.8 sq ft Distributed weight: 2.6 psf Diagram Segments Roof Section (all segments) Provided rail: 230' [14 x 14', 2 x 171 Attachments: 32 Splices: 8 Clamps: 44 T N N 511211 Columns Length Cantilever Cantilever Violations 3 10' 4" 2' 2" None 5 17' 2" 2' 7" None Row segment totals (x 2) -> 13 44' 6" 1' 3" None Splice Details r Rail Attachments Splices Clamps 28' [2 x 14'1 4 0 4 56' [4 x 14] 6 2 8 112'[8x14'] 12 4 16 90' [4 x 14', 2 x 17'1 16 4 24 Last updated by Libby Chartier on 03/02/21 12:52 PM Page 2 of 4 3929 Rockridge Parkway (#741434) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Clamp Detail Grounding Diagram OUFO Clamp --+ Fault Current Ground Path PV MODULE FRAME RAIL CAMO CAMO End Clamp, Plan • Grounding Lug * CAMO End Clamp, Front i Min 10 AWG Copper Wire * = Bonded Splice (Rail Connection) * Grounding Lugs and Wire are not required in systems using Enphase microinverters. DULE Last updated by Libby Chartier on 03/02/21 12:52 PM Page 3 of 4 3929 Rockridge Parkway (#741434) pitched roof 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Bill of Materials Part Spares Total Qty Rails & Splices XR-100-204B 0 2 XR100, Rail 204" (17 Feet) Black XR-100-168B 0 14 XR100, Rail 168" (14 Feet) Black XR100-BOSS-01-M1 0 8 Bonded Splice, XR100 Clamps & Grounding UFO-C L-01-B 1 0 44 Universal Module Clamp, Black CAMO-01-M1 0 16 Hidden End Cam (universal clamp) XR-LUG-03-Al 0 4 Grounding Lug, Low Profile Attachments LFT-03-B1 0 32 Slotted L-Foot, Black BHW-SQ-02-Al 0 32 Square -Bolt Bonding Hardware Last updated by Libby Chartier on 03/02/21 12:52 PM Page 4 of 4