HomeMy WebLinkAboutPermit File BLD-2021-0163 3929 Rock Ridge Parkway (3)CITY OF ANACORTES
BUILDING DEPARTMENT
(360) 293-1901
Job Address: 3929 ROCK RIDGE PKWY APN:
Permit Type: PV Solar Permit
Remarks: INSTALL RACKING FOR ROOF MOUNTED SOLAR PV SYSTEM.
Applicant:
ECOTECH SOLAR
1331 MEADOR AVE
BELLINGHAM, WA 98229
(360)318-7646
Contractor:
ECOTECH SOLAR
SUITE 1331 MEADOR AVE
BELLINGHAM WA98229
(360)318-7646
License #:
INSPECTION CARD
(Card to be on job site at all times)
Permit #: BLD-2021-0163 Issue date: 03/02/2021
Expire date: 08/29/2022
Owner:
MICHAEL & VICKIE HAMLETT
SUITE 994 CLERMONT DR
RICHLAND WA 99352-9507
Lender:
Inspection:
Date.
Inspector's
Initials
Comments:
Inspection:
Date.
Inspector's
Initials
Comments:
Stormwater BMPs *
Gas Piping ***
Setbacks
Rough Ducts & Vents ***
Site, Soil & Footings**
Vent Termination Clearances
Post Pads **
Appliance Installation
SIGN FINAL ***
Dryer Vent Installation ***
INSPECTION CARD for:
Mechanical, Plumbing, Sign,
Solar
Re -roof, Fence, & Decks
Plumbing Ground Work ***
Drywall
Side Sewer ***
MECHANICAL FINAL
Rough Plumbing ***
FENCE FINAL
* DO NOT clear, grade, or dig before
Stormwater BMPs inspection passes
**DO NOT cover with concrete until
inspection has passed
*** DO NOT cover until signed off
Drywall
Stormwater BMPs *
Water Line Installation ***
Setbacks
Water Piping Installation ***
Site, Soil & Footings **
PLUMBING FINAL
Post Pads **
Roof Sheathing Nailing ***
Deck Framing
RE -ROOF FINAL /Solar
BUILDING FINAL
ghteen inches unobstructed pathway
maintained along each side of any
zontal ridge per IFC 1204.2.1
Not applicable if roof
pitch is 2:12 or less.
CITY OF ANACORTES
INNING AND BUILDING DEPT:
APPROVED PLANS
REVIE�,tSS1/ B F20&T81�QMPLIANCE
MIT#: UU 55
CRESS: 3929 Rock Ri e _
'ROVED BY:
TO FIELD INSPECTION. APPROVED PL S SHALL NOT
BE ALTERED WITHOUT AUTHORIZA ON.
�OFOR CODE Cp�A
Y O {�
3929 Rock
•a w d
bdga
w
QFOR LVVECp
�G1TY
n
M
.� 4COR��;. �.� City of Anacortes Photovoltaic System Permit
��'o Fran�-
`�,�o�z� Submittal Requirements
Permit Required: A building permit is required for the installation or replacement of
solar/photovoltaic (PV) systems, including roof top arrays, ground -mounted arrays and PV
water heaters. An electrical permit is required from the State Department of Labor &
Industries.
Single family residence rooftop installations meeting the criteria in the attached checklist are
eligible to obtain a building permit over-the-counter at the permit center in City Hall.
CODES: International Residential Code (Current Edition)
International Building Code (Current Edition)
International Fire Code (Current Edition)
National Electrical Code (Current Edition)
FEES: Building Permits for installations are based on the material cost of the support system
and labor for the installation.
SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS):
1) Permit Application Form A.
2) Site plan showing location of house and array/equipment on lot, with setback
dimensions to property lines.
3) Roof plan showing the array.
4) Manufacturer specifications or the PV panels and mounting hardware. Include the
weight of the equipment.
5) For rooftop systems not conforming to all of the criteria in the attached checklist,
provide a roof framing plan and either:
a) Structural calculations by a WA State Licensed Engineer or other competent person
showing the adequacy of the existing roof structure to support the additional load,
or
b) Documentation showing that the roof structure was substantially overbuilt
compared to prescriptive code requirements.
6) For ground mounted systems provide structural calculations by a WA state licensed
engineer or other competent person showing how the structure meets wind design
requirements for the structure and footings. Note that ground mounted equipment
greater than 36 inches in height must adhere to minimum required property line
setbacks of the applicable zoning district.
NOTE: The Duraose of this handout is to assist the public in comDlvine with detailed Dermit
submittal requirements. It is NOT a complete list of permit or code requirements and
should NOT be used as a substitute for applicable laws and regulations. It is the
responsibility of the owner/design professional to review the submittal for completeness
and aDDlicability to other codes. Only complete aDDlications will be accented by the Citv for
review
QF0R LVVECp
�G1TY o�{7
n
M
YV
COR`°
'"F'cLn1"1 To Be Completed By the Applicant
Project Address: 3929 Rock Ridge Parkway
Project Applicant: Ecotech Energy Systems LLC DBA Ecotech Solar
Applicant Email: info@ecotechsolar.com Phone No.: 360-318-7646
Site Owner Name: Ross Hamlett & Vickie Capps
PV System Description: 8.71 kW roof mounted solar electric system
Determine if your project is eligible for an over-the-counter Permit (Check Yes or No)
Yes
No
1. PV System is designed and proposed for a detached single-family house, duplex or
X
❑
townhome.
2. PV System is designed for rooftop of house in general compliance with applicable
g
❑
codes.
3. Mounting system is engineered and designed for PV.
X
❑
4. Rooftop is made from light weight material such as shingles.
X
❑
5. PV system will be permitted and pre -approved by Labor & Industries Electrical
X
❑
division.
6. To address uplift, panel are mounted no higher than 18" above the surface of the
X
❑
roofing to which they are affixed. Except for flat roofs, no portion of the system
may exceed the highest point of the roof.
7. Total deal load of panels, supports, mountings, race ways, and all other
X
❑
appurtenances weight no more than one of the following. IF Yes, indicate which:
❑ No more than three and one half (3.5 pounds per square foot (PSF)
❑ Frameless panels on at least 3/12 pitch roof weighing no more than four and
one-half (4.5) PSF
❑ Frameless panels on at least 5/12 pitch roof weighing no more than five (5.0)
PSF
8. Supports for solar panels are installed to spread the dead load across as many
X
❑
roof -framing members as needed to ensure that no point loads in excess of fifty
(50) pounds are created.
9. Attachment to the roof is specified by the mounting system manufacturer.
X
❑
10. Panels are mounted no higher than the roof ridge or apex of roof (applies only to
X
❑
pitched roofs).
Comments:
m By Checking this box, I certify that all of the information provided on this form is correct.
If you answered yes to all of the above questions, your PV installation is eligible for an over-the-counter
building permit. To apply please bring in this completed form to our permit center at City Hall for an
over-the-counter permit.
To be Completed By Staff
Project is eligible for over-the-counter permit? ❑ Yes ❑ No
aF011,
COO-P cQ
Y�O�{�
C I RON RI DGE Engineering Design Guide Overview
FIFL IN
Assembled Views
4
4
F i f
5 Y
Y l
7
I
_
r
M
FEW
Flush Mounted
Tilt Mounted
For a complete 360 degree interactive roof mounting viewing environment, go to: ironridge.com/products/roofmounting/360view.
support@ I ironridge.com 1 (800) 227-9523 Page 2 2015 v1.73
QFpR COOS Cp
O�{�
M
�r0 FIELD
IR�NRIDGE
XR1000 Rail
Engineering Design Guide System Parts
XR1000 is a heavyweight among solar mounting rails, built to handle extreme climates and spans 12 feet or more for commercial applications.
No
II
r-
XR100 Rail
Property
Material
Finish
Beam Height
Weight / Linear Foot
Total Cross -Sectional Area
Section Modulus (X-axis)
Moment of Inertia (X-axis)
Moment of Inertia (Y-axis)
Torsional Constant
Polar Moment of Inertia
Value
6000 Series Aluminum
Clear Anodized
3.00"
0.945 Lbs
0.807 In
0.530 Ina
0.843 In
0.182 In
0.436 In 3
0.3299 In
XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans.
Property
Material
Finish
Beam Height
Weight / Linear Foot
Total Cross -Sectional Area
Section Modulus (X-axis)
Moment of Inertia (X-axis)
Moment of Inertia (Y-axis)
Torsional Constant
Polar Moment of Inertia
ff"MITis
Value
6000 Series Aluminum
Clear& Black Anodized
2.44"
0.68 Lbs
0.582 In
0.297 In 3
0.390 In
0.085 In
0.214 Ina
0.126 In
XR10 is a low -profile mounting rail, perfectly matched to regions with light snow. It achieves 6 foot spans, while staying light and economical.
Property
Material
Finish
Beam Height
Weight / Linear Foot
Total Cross -Sectional Area
Section Modulus (X-axis)
Moment of Inertia (X-axis)
Moment of Inertia (Y-axis)
Torsional Constant
Polar Moment of Inertia
Value
6000 Series Aluminum
Clear & Black Anodized
1.75"
0.436 Lbs
0.363 In
0.136 Ina
0.124 In
0.032 In
0.076 In 3
0.033 In
support@ I ironridge.com 1 (800) 227-9523 Page 5 2015 v1.73
QFpR CODE Cp
O�{�
M
�r0 FIELD
IRONRIDGE
Internal Splice
Engineering Design Guide System Parts
IronRidge Rails are easy to extend with our patent -pending Internal Splices.
Property Value
Material 6000 Series Aluminum
Finish Mill
Length 12"
1 Hardware 2 SS Self -tapping Screws
End Clamp
IronRidge End Clamps secure PV modules to XR Rails using the top slot, independent upon the module's mounting holes.
Property
Material
Finish
Height
Width
Depth
Weight
Hardware
Mid Clamp
IronRidge Mid Clamps secure PV modules to the rail when there are multiple modules in a row.
Property
Material
Finish
Spacing between Modules
Width
Depth
Weight
Hardware
Grounding Mid Clamp
Grounding Mid Clamps pierce through anodized coatings to ground array, being ETL listed to UL 2703.
��—"+• Property
\ Material
Finish
Spacing between Modules
Width
Depth
Weight
Hardware
support@ ironridge.com (800) 227-9523 Page 6
Value
5000 & 6000 Series Aluminum
Mill & Black
Varies depending on Module
1.5"
1.5"
0.05 Lbs
1/4"-20 SS Nut and Bolt
Value
5000 Series Aluminum
Mill & Black
1/4„
1"
1.5"
0.05 Lbs
1/4"-20 SS Nut and Bolt
Value
304 Stainless Steel
Mill & Black
1/4"
1"
1.2"
0.08 Lbs
1/4"-20 SS Nut and Bolt
2015 v1.73
R
FOR cony cQ
� YD-P {9�
IRONRIDGE
CO1
Assembly CAD Details
Typical Flush Mount Array - Plan View
1/2" = 1'-0"
MountSection - Flush o
Engineering Design Guide
— SLOPE
3/4" = 1'-0"
XR ftl
Reer Tilt Leg(L,Ng Vanes) m
fi" Frent Tilt Leg
Steel Sfantloff
Exisgng Roof S[mclure MembrenellnsulaUon
Section - Tilt Mount - Flat Roof
3/4" = 1'-0"
Mid Clamp
End Clamp
Detail D - Mid Clamp to Rail - Elevation Detail E - End Clamp to Rail - Elev.
6" = 1' -0" 6" = 1' -0"
Mid Clamp
XR Rail
Overview
Download Al File I Download PDF
Mid Clamp
(iD
Detail A - Mid Clamp to Rail - Plan
3" = 1' -0"
End Clamp
Detail B - End Clamp to Rail - Plan
3" = 1' -0"
Detail C - Typical Roof Connection
3" = 1' -0"
-'3r Panel
L-Foot
>hing
ting Roof Structure
XR ftl VARIES
C D E
L-Foot
Exlsgng ROM Structure
VARIES
Existing Roof SlrucWre
Section - Flush Mount - Sloped Roof
3/4" = 1' -0" Typical Flush Mount Array - Elevation
3/4" = 1'-0"
support@ I ironridge.com 1 (800) 227-9523 Page 4
2015 0.73
Residential Building Permit Application
City of Anacortes Building Department
P.O. Box 547 Anacortes, WA 98221
Street Address: 904 6t" Street
Phone: (360) 293-1901 Fax: (360) 293-1938
SITE ADDRESS: 3929 Rock Ridge Parkway I
CONTRACTOR M Applicant I PROJECT DESCRIPTION III
Ecotech Solar
Address 1331 Meador Ave, Ste 103
City/State/Zip Bellingham, WA 98229
Phone 360-318-7646 FAX
Racking for roof mounted solar electric system
State License # 602-441-974 EXp 10.31.21
PARCEL NUMBER
City of Anacortes Business License: X Yes [:]No
P 133959
PROPERTY OWNER ❑ Applicant LEGAL DESCRIPTION
Name Ross Hamlett &Vickie Capps (0ECORD.2202
ON NOVEMBER 6, 01 RIDN ER AUDITORS FI EGE SOUTH, PHASE 4, AS PER PLAT
994 Clermont Dr NO. 201711060065, RECORDS OF SKAGIT COUNTY, WASHINGTON.
City/State/zip Richland, WA 99352 PROJECT VALUATION
Phone 509-942-9292 FAX $2005.00
Number of Dwelling Units
E-Mail Address mrhamlet@icloud.com, Number of Stories
vlcapps@icloud.com Building Area:
❑ Architect ❑ Designer ❑ Engineer ❑ Applicant 1st Floor s.f. 2nd Floor s.f.
Name _ 1 3`d Floor s.f. Basement s.f
Address Garage s.f. Carport s.f.
City/State/Zip _ Deck s.f. Lot Area s.f.
Phone FAX
E-mail Address
CONTACT ❑ Applicant LENDER
Name Libby Chattier - ECOtech Solar
LENDER INFORMATION MUST BE PROVIDED FOR PROJECTS OVER $5,000
IN VALUATION PER RCW.
Address see applicant above Name
City/State/Zip Address
Phone FAX City/State/Zip
E-mail Address Phone No.
CONTINUED ON THE BACK
FOR L VVE co
'LLo
❑ Natural Gas
Residential Mechanical Fixtures
Fuel Type
❑x Electric ❑ Wood ❑ Propane Gas ❑ Other
Type of Equipment
Number of
Fixtures
Type of Equipment
Number of
Fixtures
Furnace <=100K BTU
Clothes Dryer
Boilers/AC/Heat Pump
Gas Water Heater
Gas Outlets
Gas Fire lace
Ventilation Fans
Fire lace Insert
Stove, Appliance
Other Units
Range Hood
PV Array
x
Residential Plumbing Fixtures
Type of Fixture
Number of
Fixtures
Type of Fixture
Number of
Fixtures
Toilet
Clothes Washer
Bathtub
Electric Water Heater
Shower
Utilit Sink
Dishwasher
Hose Bibb
Hand Sink
Water Piping
Kitchen Sink w/Dis osal
Additional Fixtures
I HEREBY ACKNOWLEDGE IF HAVE READ THIS PERMIT APPLICANT AND STATE THE INFORMATION IS CORRECT, AND AGREE TO COMPLY WITH ALL CITY
ORDINANCES AND STATE LAWS REGULATING ACITIVIES COVERED BY THIS PERMIT APPLICATION. WITH THIS PERMIT ALL CONTRACTORS AND
SUBCONTRACTORS SHALL HAVE A CURRENT WASHINGTON STATE CONTRACTORS LICENSE AND A CITY BUSINESS LICENSE. STOP WORK ORDERS
WILL BE ISSUED ON JOB SITES WHERE CONTRACTORS/SUBCONTRACTORS ARE WORKING WITHOUT PROPER LICENSE.
3/2/2021
APP A T'S SIGNATURE DATE
Last Updated Nov. 9, 2012
Dimensions
ASCE
Parkway (#741434)
3929 Rockridge Parkway
3929 Rockridge Parkway, Anacortes, WA 98221
Hanwha Q.Cells: Q.PEAK DUO BLK-G6+ 335 (32mm)
68.5" x 40.55" x 1.26" (1740.0mm x 1030.Omm x 32.Omm)
7-10
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Date
03/02/2021
Total modules
26
Total watts
8,710
Attachments
32
System Weight
Load Assumptions
Total system weight
1,332.8 Ibs
Wind exposure
B
Weight/attachment
41.6 Ibs
Wind speed
110 mph
Racking weight
191.9 Ibs
Ground snow load
15 psf
Distributed weight
2.6 psf
Attachment spacing portrait
6.0'
Roof Information
Roof material
Metal
Building height
30 ft
Roof attachment
L-Foot Only
Roof slope
9 °
Attachment hardware
Square
Risk category
II
Span Details XR100 - Portrait
Reaction Forces XR100 - Portrait
Zone Down
Uplift
Lateral
Zone Max span
Max cantilever
(Ibs)
(Ibs)
(Ibs)
1 8' 5"
3' 4"
1 354
135
54
2 8' 5"
3' 4"
2 354
281
54
3 8' 1"
3' 3"
3 354
450
54
Last updated by Libby Chartier on 03/02/21 12:52 PM
Page 1of4
Parkway (#741434)
Por`Erait orientation
Graphical entry
Diagram
Segments
Roof Section Weights
Total weight: 1,332.8 Ibs
Weight/attachment: 41.6 Ibs
Total Area: 509.8 sq ft
Distributed weight: 2.6 psf
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Roof Section (all segments)
Provided rail: 230' [14 x 14', 2 x 171
Attachments: 32
Splices: 8
Clamps: 44
T
N
N
511211
Columns Length Cantilever Cantilever Violations
3 10' 4" 2' 2" None
5 17' 2" 2' 7" None
Row segment totals (x 2) ->
13 44' 6" 1' 3" None
Splice Details
r
Rail
Attachments
Splices
Clamps
28' [2 x 14'1
4
0
4
56' [4 x 14]
6
2
8
112'[8x14']
12
4
16
90' [4 x 14', 2 x 17'1
16
4
24
Last updated by Libby Chartier on 03/02/21 12:52 PM
Page 2 of 4
Grounding Diagram
Nay (#741434)
OUFO Clamp
--+ Fault Current Ground Path
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
PV MODULE
FRAME
RAIL
CAMO
CAMO End Clamp, Plan
• Grounding Lug *
CAMO End Clamp, Front
Min 10 AWG Copper Wire *
= Bonded Splice (Rail Connection)
* Grounding Lugs and Wire are not required in systems using Enphase microinverters.
DULE
Last updated by Libby Chartier on 03/02/21 12:52 PM
Page 3of4
'arkway (#741434)
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Spares
XR-100-204B
XR100, Rail 204" (17 Feet) Black
XR-100-168B
XR100, Rail 168" (14 Feet) Black
XR100-BOSS-01-M1
Bonded Splice, XR100
Clamps & Grounding
UFO-C L-01-B 1
Universal Module Clamp, Black
CAMO-01-M1
Hidden End Cam (universal clamp)
XR-LUG-03-Al
Grounding Lug, Low Profile
Attachments
LFT-03-B1
Slotted L-Foot, Black
BHW-SQ-02-Al
Square -Bolt Bonding Hardware
Total Qty
2
14
8
44
16
4
32
32
Last updated by Libby Chartier on 03/02/21 12:52 PM Page 4 of 4