HomeMy WebLinkAboutPermit File BLD-2021-0163 3929 Rock Ridge Parkway (3)CITY OF ANACORTES BUILDING DEPARTMENT (360) 293-1901 Job Address: 3929 ROCK RIDGE PKWY APN: Permit Type: PV Solar Permit Remarks: INSTALL RACKING FOR ROOF MOUNTED SOLAR PV SYSTEM. Applicant: ECOTECH SOLAR 1331 MEADOR AVE BELLINGHAM, WA 98229 (360)318-7646 Contractor: ECOTECH SOLAR SUITE 1331 MEADOR AVE BELLINGHAM WA98229 (360)318-7646 License #: INSPECTION CARD (Card to be on job site at all times) Permit #: BLD-2021-0163 Issue date: 03/02/2021 Expire date: 08/29/2022 Owner: MICHAEL & VICKIE HAMLETT SUITE 994 CLERMONT DR RICHLAND WA 99352-9507 Lender: Inspection: Date. Inspector's Initials Comments: Inspection: Date. Inspector's Initials Comments: Stormwater BMPs * Gas Piping *** Setbacks Rough Ducts & Vents *** Site, Soil & Footings** Vent Termination Clearances Post Pads ** Appliance Installation SIGN FINAL *** Dryer Vent Installation *** INSPECTION CARD for: Mechanical, Plumbing, Sign, Solar Re -roof, Fence, & Decks Plumbing Ground Work *** Drywall Side Sewer *** MECHANICAL FINAL Rough Plumbing *** FENCE FINAL * DO NOT clear, grade, or dig before Stormwater BMPs inspection passes **DO NOT cover with concrete until inspection has passed *** DO NOT cover until signed off Drywall Stormwater BMPs * Water Line Installation *** Setbacks Water Piping Installation *** Site, Soil & Footings ** PLUMBING FINAL Post Pads ** Roof Sheathing Nailing *** Deck Framing RE -ROOF FINAL /Solar BUILDING FINAL ghteen inches unobstructed pathway maintained along each side of any zontal ridge per IFC 1204.2.1 Not applicable if roof pitch is 2:12 or less. CITY OF ANACORTES INNING AND BUILDING DEPT: APPROVED PLANS REVIE�,tSS1/ B F20&T81�QMPLIANCE MIT#: UU 55 CRESS: 3929 Rock Ri e _ 'ROVED BY: TO FIELD INSPECTION. APPROVED PL S SHALL NOT BE ALTERED WITHOUT AUTHORIZA ON. �OFOR CODE Cp�A Y O {� 3929 Rock •a w d bdga w QFOR LVVECp �G1TY n M .� 4COR��;. �.� City of Anacortes Photovoltaic System Permit ��'o Fran�- `�,�o�z� Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic (PV) systems, including roof top arrays, ground -mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor & Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code (Current Edition) International Fire Code (Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot, with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE: The Duraose of this handout is to assist the public in comDlvine with detailed Dermit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and aDDlicability to other codes. Only complete aDDlications will be accented by the Citv for review QF0R LVVECp �G1TY o�{7 n M YV COR`° '"F'cLn1"1 To Be Completed By the Applicant Project Address: 3929 Rock Ridge Parkway Project Applicant: Ecotech Energy Systems LLC DBA Ecotech Solar Applicant Email: info@ecotechsolar.com Phone No.: 360-318-7646 Site Owner Name: Ross Hamlett & Vickie Capps PV System Description: 8.71 kW roof mounted solar electric system Determine if your project is eligible for an over-the-counter Permit (Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house, duplex or X ❑ townhome. 2. PV System is designed for rooftop of house in general compliance with applicable g ❑ codes. 3. Mounting system is engineered and designed for PV. X ❑ 4. Rooftop is made from light weight material such as shingles. X ❑ 5. PV system will be permitted and pre -approved by Labor & Industries Electrical X ❑ division. 6. To address uplift, panel are mounted no higher than 18" above the surface of the X ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels, supports, mountings, race ways, and all other X ❑ appurtenances weight no more than one of the following. IF Yes, indicate which: ❑ No more than three and one half (3.5 pounds per square foot (PSF) ❑ Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half (4.5) PSF ❑ Frameless panels on at least 5/12 pitch roof weighing no more than five (5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many X ❑ roof -framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. X ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof (applies only to X ❑ pitched roofs). Comments: m By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions, your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑ Yes ❑ No aF011, COO-P cQ Y�O�{� C I RON RI DGE Engineering Design Guide Overview FIFL IN Assembled Views 4 4 F i f 5 Y Y l 7 I _ r M FEW Flush Mounted Tilt Mounted For a complete 360 degree interactive roof mounting viewing environment, go to: ironridge.com/products/roofmounting/360view. support@ I ironridge.com 1 (800) 227-9523 Page 2 2015 v1.73 QFpR COOS Cp O�{� M �r0 FIELD IR�NRIDGE XR1000 Rail Engineering Design Guide System Parts XR1000 is a heavyweight among solar mounting rails, built to handle extreme climates and spans 12 feet or more for commercial applications. No II r- XR100 Rail Property Material Finish Beam Height Weight / Linear Foot Total Cross -Sectional Area Section Modulus (X-axis) Moment of Inertia (X-axis) Moment of Inertia (Y-axis) Torsional Constant Polar Moment of Inertia Value 6000 Series Aluminum Clear Anodized 3.00" 0.945 Lbs 0.807 In 0.530 Ina 0.843 In 0.182 In 0.436 In 3 0.3299 In XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. Property Material Finish Beam Height Weight / Linear Foot Total Cross -Sectional Area Section Modulus (X-axis) Moment of Inertia (X-axis) Moment of Inertia (Y-axis) Torsional Constant Polar Moment of Inertia ff"MITis Value 6000 Series Aluminum Clear& Black Anodized 2.44" 0.68 Lbs 0.582 In 0.297 In 3 0.390 In 0.085 In 0.214 Ina 0.126 In XR10 is a low -profile mounting rail, perfectly matched to regions with light snow. It achieves 6 foot spans, while staying light and economical. Property Material Finish Beam Height Weight / Linear Foot Total Cross -Sectional Area Section Modulus (X-axis) Moment of Inertia (X-axis) Moment of Inertia (Y-axis) Torsional Constant Polar Moment of Inertia Value 6000 Series Aluminum Clear & Black Anodized 1.75" 0.436 Lbs 0.363 In 0.136 Ina 0.124 In 0.032 In 0.076 In 3 0.033 In support@ I ironridge.com 1 (800) 227-9523 Page 5 2015 v1.73 QFpR CODE Cp O�{� M �r0 FIELD IRONRIDGE Internal Splice Engineering Design Guide System Parts IronRidge Rails are easy to extend with our patent -pending Internal Splices. Property Value Material 6000 Series Aluminum Finish Mill Length 12" 1 Hardware 2 SS Self -tapping Screws End Clamp IronRidge End Clamps secure PV modules to XR Rails using the top slot, independent upon the module's mounting holes. Property Material Finish Height Width Depth Weight Hardware Mid Clamp IronRidge Mid Clamps secure PV modules to the rail when there are multiple modules in a row. Property Material Finish Spacing between Modules Width Depth Weight Hardware Grounding Mid Clamp Grounding Mid Clamps pierce through anodized coatings to ground array, being ETL listed to UL 2703. ��—"+• Property \ Material Finish Spacing between Modules Width Depth Weight Hardware support@ ironridge.com (800) 227-9523 Page 6 Value 5000 & 6000 Series Aluminum Mill & Black Varies depending on Module 1.5" 1.5" 0.05 Lbs 1/4"-20 SS Nut and Bolt Value 5000 Series Aluminum Mill & Black 1/4„ 1" 1.5" 0.05 Lbs 1/4"-20 SS Nut and Bolt Value 304 Stainless Steel Mill & Black 1/4" 1" 1.2" 0.08 Lbs 1/4"-20 SS Nut and Bolt 2015 v1.73 R FOR cony cQ � YD-P {9� IRONRIDGE CO1 Assembly CAD Details Typical Flush Mount Array - Plan View 1/2" = 1'-0" MountSection - Flush o Engineering Design Guide — SLOPE 3/4" = 1'-0" XR ftl Reer Tilt Leg(L,Ng Vanes) m fi" Frent Tilt Leg Steel Sfantloff Exisgng Roof S[mclure MembrenellnsulaUon Section - Tilt Mount - Flat Roof 3/4" = 1'-0" Mid Clamp End Clamp Detail D - Mid Clamp to Rail - Elevation Detail E - End Clamp to Rail - Elev. 6" = 1' -0" 6" = 1' -0" Mid Clamp XR Rail Overview Download Al File I Download PDF Mid Clamp (iD Detail A - Mid Clamp to Rail - Plan 3" = 1' -0" End Clamp Detail B - End Clamp to Rail - Plan 3" = 1' -0" Detail C - Typical Roof Connection 3" = 1' -0" -'3r Panel L-Foot >hing ting Roof Structure XR ftl VARIES C D E L-Foot Exlsgng ROM Structure VARIES Existing Roof SlrucWre Section - Flush Mount - Sloped Roof 3/4" = 1' -0" Typical Flush Mount Array - Elevation 3/4" = 1'-0" support@ I ironridge.com 1 (800) 227-9523 Page 4 2015 0.73 Residential Building Permit Application City of Anacortes Building Department P.O. Box 547 Anacortes, WA 98221 Street Address: 904 6t" Street Phone: (360) 293-1901 Fax: (360) 293-1938 SITE ADDRESS: 3929 Rock Ridge Parkway I CONTRACTOR M Applicant I PROJECT DESCRIPTION III Ecotech Solar Address 1331 Meador Ave, Ste 103 City/State/Zip Bellingham, WA 98229 Phone 360-318-7646 FAX Racking for roof mounted solar electric system State License # 602-441-974 EXp 10.31.21 PARCEL NUMBER City of Anacortes Business License: X Yes [:]No P 133959 PROPERTY OWNER ❑ Applicant LEGAL DESCRIPTION Name Ross Hamlett &Vickie Capps (0ECORD.2202 ON NOVEMBER 6, 01 RIDN ER AUDITORS FI EGE SOUTH, PHASE 4, AS PER PLAT 994 Clermont Dr NO. 201711060065, RECORDS OF SKAGIT COUNTY, WASHINGTON. City/State/zip Richland, WA 99352 PROJECT VALUATION Phone 509-942-9292 FAX $2005.00 Number of Dwelling Units E-Mail Address mrhamlet@icloud.com, Number of Stories vlcapps@icloud.com Building Area: ❑ Architect ❑ Designer ❑ Engineer ❑ Applicant 1st Floor s.f. 2nd Floor s.f. Name _ 1 3`d Floor s.f. Basement s.f Address Garage s.f. Carport s.f. City/State/Zip _ Deck s.f. Lot Area s.f. Phone FAX E-mail Address CONTACT ❑ Applicant LENDER Name Libby Chattier - ECOtech Solar LENDER INFORMATION MUST BE PROVIDED FOR PROJECTS OVER $5,000 IN VALUATION PER RCW. Address see applicant above Name City/State/Zip Address Phone FAX City/State/Zip E-mail Address Phone No. CONTINUED ON THE BACK FOR L VVE co 'LLo ❑ Natural Gas Residential Mechanical Fixtures Fuel Type ❑x Electric ❑ Wood ❑ Propane Gas ❑ Other Type of Equipment Number of Fixtures Type of Equipment Number of Fixtures Furnace <=100K BTU Clothes Dryer Boilers/AC/Heat Pump Gas Water Heater Gas Outlets Gas Fire lace Ventilation Fans Fire lace Insert Stove, Appliance Other Units Range Hood PV Array x Residential Plumbing Fixtures Type of Fixture Number of Fixtures Type of Fixture Number of Fixtures Toilet Clothes Washer Bathtub Electric Water Heater Shower Utilit Sink Dishwasher Hose Bibb Hand Sink Water Piping Kitchen Sink w/Dis osal Additional Fixtures I HEREBY ACKNOWLEDGE IF HAVE READ THIS PERMIT APPLICANT AND STATE THE INFORMATION IS CORRECT, AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING ACITIVIES COVERED BY THIS PERMIT APPLICATION. WITH THIS PERMIT ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT WASHINGTON STATE CONTRACTORS LICENSE AND A CITY BUSINESS LICENSE. STOP WORK ORDERS WILL BE ISSUED ON JOB SITES WHERE CONTRACTORS/SUBCONTRACTORS ARE WORKING WITHOUT PROPER LICENSE. 3/2/2021 APP A T'S SIGNATURE DATE Last Updated Nov. 9, 2012 Dimensions ASCE Parkway (#741434) 3929 Rockridge Parkway 3929 Rockridge Parkway, Anacortes, WA 98221 Hanwha Q.Cells: Q.PEAK DUO BLK-G6+ 335 (32mm) 68.5" x 40.55" x 1.26" (1740.0mm x 1030.Omm x 32.Omm) 7-10 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Date 03/02/2021 Total modules 26 Total watts 8,710 Attachments 32 System Weight Load Assumptions Total system weight 1,332.8 Ibs Wind exposure B Weight/attachment 41.6 Ibs Wind speed 110 mph Racking weight 191.9 Ibs Ground snow load 15 psf Distributed weight 2.6 psf Attachment spacing portrait 6.0' Roof Information Roof material Metal Building height 30 ft Roof attachment L-Foot Only Roof slope 9 ° Attachment hardware Square Risk category II Span Details XR100 - Portrait Reaction Forces XR100 - Portrait Zone Down Uplift Lateral Zone Max span Max cantilever (Ibs) (Ibs) (Ibs) 1 8' 5" 3' 4" 1 354 135 54 2 8' 5" 3' 4" 2 354 281 54 3 8' 1" 3' 3" 3 354 450 54 Last updated by Libby Chartier on 03/02/21 12:52 PM Page 1of4 Parkway (#741434) Por`Erait orientation Graphical entry Diagram Segments Roof Section Weights Total weight: 1,332.8 Ibs Weight/attachment: 41.6 Ibs Total Area: 509.8 sq ft Distributed weight: 2.6 psf 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Roof Section (all segments) Provided rail: 230' [14 x 14', 2 x 171 Attachments: 32 Splices: 8 Clamps: 44 T N N 511211 Columns Length Cantilever Cantilever Violations 3 10' 4" 2' 2" None 5 17' 2" 2' 7" None Row segment totals (x 2) -> 13 44' 6" 1' 3" None Splice Details r Rail Attachments Splices Clamps 28' [2 x 14'1 4 0 4 56' [4 x 14] 6 2 8 112'[8x14'] 12 4 16 90' [4 x 14', 2 x 17'1 16 4 24 Last updated by Libby Chartier on 03/02/21 12:52 PM Page 2 of 4 Grounding Diagram Nay (#741434) OUFO Clamp --+ Fault Current Ground Path 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 PV MODULE FRAME RAIL CAMO CAMO End Clamp, Plan • Grounding Lug * CAMO End Clamp, Front Min 10 AWG Copper Wire * = Bonded Splice (Rail Connection) * Grounding Lugs and Wire are not required in systems using Enphase microinverters. DULE Last updated by Libby Chartier on 03/02/21 12:52 PM Page 3of4 'arkway (#741434) 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Spares XR-100-204B XR100, Rail 204" (17 Feet) Black XR-100-168B XR100, Rail 168" (14 Feet) Black XR100-BOSS-01-M1 Bonded Splice, XR100 Clamps & Grounding UFO-C L-01-B 1 Universal Module Clamp, Black CAMO-01-M1 Hidden End Cam (universal clamp) XR-LUG-03-Al Grounding Lug, Low Profile Attachments LFT-03-B1 Slotted L-Foot, Black BHW-SQ-02-Al Square -Bolt Bonding Hardware Total Qty 2 14 8 44 16 4 32 32 Last updated by Libby Chartier on 03/02/21 12:52 PM Page 4 of 4