Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0575 3809 37th Drive (5)SCOPE OF WORK r .� ;� .. s PROPOSED NEW 4.1E KW (DC) ROOF MOUNTED Y OF NACORTES PHOTOVOLTAIC (PV) SYSTEM WITH FOLLOWING EQUIPMENT: BUILDING DEPT: -S320RGIBKI SOLAR MODULES HYUNDAI HID ED PLANS z rc�vi� xz" (1) SOLAREDGE SE5000H-US INVERTER C QQ Ai UNIRAC SOLARMOUNT FLUSH RACKING SYSTEM J1l tSL�CC175 x. APP SITE SPECIFICATIONS ECT T�F T APPROVED PL S SHALL NOT ELECTRIC UTILITY PROVIDER: PUGET SOUND ENERGY ALTE ELECTRIC SERVICE RATING: 200A a. ROOF MATERIAL: COMPOSITE SHINGLE, ASCE 7-10 WIND EXPOSURE CATEGORY: B ASCE 7-10 GROUND SNOW LOAD: 25 PSF �•. ,� CAPST°NE ASCE 7-10 WINDSPEEDS (3 SEC GUST IN MPH) SOLAR -RISK CATEGORY I: 10000 -RISK CATEGORY II: 1 10 ��' DESCRIPTION DATE REVISION -RISK CATEGORY III -IV: 1 15 INITIAL 8.JUL.2021 ASCE 7-05 WINDSPEED: 85 (3-SEC PEAK GUST IN MPH) ASCE 7-93 WINDSPEED: 71 (FASTEST MILE IN MPH) f CODE AUTHORITY 2018 WASHINGTON STATE FIRE CODE (2018 IFC) - Solar Specialist 2020 WAC 296-46B (2020 NEC, WITH WAC AMENDMENTS) , `• TAYLOR DISCH 2018 WASHINGTON STATE ENERGY CODE 2018 IECC System Engineer 2018 WASHINGTON STATE BUILDING COD 2018 IBC) 2018 WASHINGTON STATE RESIDENTIAL CODE - T1M WACHTMAN aJ J I (2018 INTERNATIONAL RESIDENTIAL CODE, WASHINGTON AMENDMENTS 2018 WAC51-51-2300 SECTION M2301) Y f. System Designer 2018 WASHINGTON STATE PLUMBING CODE 2018 UPCI ti - CASEY MILLER 2018 WASHINGTON STATE MECHANICAL CODE (2018 IVIC + ,h. Customer Info SHEET INDEX Pf IOTOVOLTAIC �vOT�S JE 3809 TH DR ZO. ALL WIPING CONGEALED INWALL AND CEILING SPACES SHALL Of IN METAL CONDUIT, 3809 3 7TH DR 2r, rnf SEISM G PPAcwG AND ANCHORAGE of fLEcrP GAL coNDu r5 SHALL Pf IN ACCORDANCE w rn rnf A NACO RTES, WA 98221 A-1 NOTES, INDEX, SITE INFO, PROJECT DATA, CODE"SrAGNA"-GUIDLINeSrO,PSeISrnGPeSr,PA1N5OrrlecnANlGAL5Y5Terl5ANDPLUNINGPIPING 5Y5ren5, ppRCEF#: P80341 1. AN IN✓ERrEP OP AN AC 170DULf IN AN IN-fPAC-NE PHO-OVOLTAIC 5Y5-EM SHALL AL rOMATIGALLY Df-fNEP6/ZE /T5 22, ALL OP THE LI5-fD SYSTEMS Pf0UIPF0 THAT -HE SEISMIC LfA-PAL FOPGE F INGWOING CONSIDfPATION OP a" P AND OUTPUT -O THE CONNECTED ELECTRICAL PPODUCTION AND DISTPIDUNON NETWOPK UPON L055 OF VOLTAGE IN THAT r^P DE DETEPMINED AT EACH LEVEL OF rHf PUILDING 50 TWAT PPACE 5PACING CAN DE GALCULA-ED, THE DISTRICT Project Details A-2 SITE PLAN SYSTEM AND SHALL PEMAIN IN -HAT STATE UNTIL -Hf ELECTRICAL PPODUCTION AND DISTRIOUNON NET 1VOPK VOLTAGE 5-PUGTUP. AL ENGINEEP CAN APPPOVE THE SEISM G LATEPAL FOPCE DETEPMINATION. HA5 OEM PE_ -TOPED, (NEC 690360 23. ACOPY OF rHf CHOSEN OPACING 5Y5TEMC5J INSTALLATION GUIDE/MANUAL SHALL DE ON -HE JOP 5rrf PRIOP r0 4.16 KW A-3 PV LAYOUT AND COMPONENT LOCATION Z, ALL ExTEPIOP ELECTRGAL METALLIG TUP1N6(EMT) GONDU/T FITTING SHALL Of PAIN 7-16t trT READ LE55 STARTING THE INSTALLING OF HANGERS ANDYQR DPACES ROOFTOP PV COMPPf55/ON TYPE, 24WHEN INS-ALLING DRILLED -IN ANCHOPS AND/OP POWDER DPNEN PINS IN EXISTING NON-PRE5rRE55ED 3' MODULES AND SUPPOPr STRUG-UPfS SHALL Of GPOUNDED PEINFOPCEO CONCRETE, U5f GAPE AND CAUTION TO AVOID CUTTING OR DAMAGING THE PEINFOPCED DAPS . WHEN SYSTEM E-1 ELECTRICAL LINE DIAGRAM 4, NAMEPLATES SHALL Of PPOVIDED FOP ALL GIPCU/rS IN THE SfPVIGf DISTPIOUrION AND POWfP DISTPIOUrION INSTALLING THEM INTO EXISTING PRE 5-RE55ED GONGPCTf7-fNDON5 OY USING A NON-DES-PUG-IVf METHOD PPIOP SWlrGH OOAPDS, PANEL OOAPDS, 0ISCONNEG7-IN6 SWITCHES,-EPl71NAL GADINE-S, frC ALL NAMEPLATES SHALL Of TO INSTALLATION, fXfPGlSf EX-PEI Yf GAPE AND CAUTION TO AVOID CUTTING OP DAMAGING -Hf TENDONS DUPING TILT E-2 LABELING INFORMATION PfR11AENTLYA7_7­ACHE0ANDOEOESUFFIGIf1\trGAPAGITY7-0WITHSTAND7_HEWEA7_HfP,INSTALLATION, MAINTAIN AMINIMUMGLEAPANGEOFONEINCH PfTWEENTHEPf/NFOPGfl7ENrAND THEDPILLED-INANGHOP, 5, JUNCTION PDX/GOMOINER PDX nAVETO USECOMPRESS/ON TYPE STRAIN PELIEF POSITIONED FOP APPPOPPIATE 25, THEWOPIM6 GLEAPANGES APOUNO THE EXISrlN6 ELEGTPIGAL EOUIPMENr A5 WELL A5 THE NOW ELEGTPIGAL 1 8.43' 1 4: 1 2 PITCH WATEP RUN OFF. fOU1,PI1FNrW11-L Of 11AINTA1NfD IN AGCOPOANCf WITH NEC 11026, AZIMUTH E-3 EQUIPMENT: PV MODULE SPECIFICATION SHEETS 6, G0NDUIT PUN-5 SHALL Of PP.OVIDED WITH SUFFICIENT WEATHEPPPOOF PULL PDXES OF JUNCTION P0XICOMPINEP 26, GONDUGT0P5 EXPOSED -0 SUNIJ6ttr SHALL Pf LISTED A5 5UNL16ftr PE5I5rAN7- (NEG 300,6 01, 310,8 DJ PDXES PER APPPOPP. IATE NEC REQUIREMENTS 21, GPOUNPIN6 OUSHlN65 APE PEOUIPfO APOUND PPf-PUNGHfD CONGFNTPIC KNOCKOUTS ON THE OG SIDE OF THE Z 7 00 E-4 EQUIPMENT: INVERTER SPECIFICATION SHEETS-.SEEPPOVIDEDCUT SHEErSFOP ADDmONALEQUIPMENrSPEGIFICAMNS 5r5rEM(NEC2�o.52�) 8. WIPING MA-ERlALS SHALL OE SU1TAOLE FOP THE SUN EXP05UPf AND WET LOCANON5. FIELD APPLIED PPO-ECTNf 28.7_11f GROUNDING ELECTRODE CONDUCTOP MU5r Of PROTECTED FPOM PHYSICAL DAMAGE IF 51711LLEP. THAN #6 DC SYSTEM RATING EQUIPMENT: DC/DC POWER OPTIMIZER COAT/NGSAPE NOT ACCEPTAPLE. COPPEPWIPE(NEC 250.64P) E-5 9, JUNCTION, PULL AND OUTLET OOXES LOGA-fD OfHIND MODULES SHALL Of 50 /NSTALLED -HAT THE WIPING 29, GROUNDING fl-ECTPODf CONDUCTOPWILL Of CONTINUOUS, EXCEPT FOP SPLICES OP JOINTS AT PU5PAR5 WITHIN 4. 16 kW SPECIFICATION SHEETS GON-AWED IN THEM CAN OF PENDEPED ACGE5_ /VME DIPEG-LY OP OY 015PLAGf/1fN7_OF 170DU1_f(5) SEGUPED OY L157_ED EQUIPMENT. (NEG Z50,64 C) PfMOVAOLE FA57_ENEPS AND GONNEG-fD OY A FLEXIOLEWIPING 5Y57_fM, (NEC; 69034) 30. RACEWAY FOP 6POUNOING ELECTRODE CONDUCTOR SHALL Of PONOED AT EACH END. (GEC 250.64 (f) AC SYSTEM RATING EQUIPMENT: RACKING SYSTEM, ROOF 10, IN AN UNDEPGPOUND PHOTOVOLTAIG SYSTEM, THE POWEP 50UPGE SHALL Of LAPELED WITH THE FOLLOWING 3l. WHEPE ALL TERMINALS OF THE DISCONNECTING MEANS MAY PE fNEPOIZED IN THE OPEN P05/NON, A SIGN WILL Of S- 1 WARNING AT EACH JUNCTION OOX, GO170/NEP PDX, DISCONNEC-AND DEVIGEWYIfPf THE UN6POUNDF0 GIPGUITS MAY Of PPOVIDED WARNING OF THE HAZAPD PEP NEC 690.1134. EACH UNOPOUNDED GONDUGTOP OF -Hf I1UL7_-1W1Pf OPANGH 5.0 AV ATTACHMENT EXPOSED DUPING SfPVIGf ; "WAPNIN6 - ft-fG-PIG SHOGK HAZAPD, THE CUPPENT CIPCUIT GONDUGrOPS OF THIS GOGUIT W11-1- Of 10ENTIFIM PEP PHASE AND 5Y5rEM PEP NfG210,5, PHOTOVOLTAIGPOWFPSYSTEMAPFUNGPOUNDfDOUTMAY OFfNFPG1ZfDWITHTHEPESPEG--0GPOUNDDUfTO 32,GIPGU1T5OVEP250V7-0GPOUNDSHALLCOMPLYWITHNEG250,99ff25092(0)dLA11G93250,91 ESTIMATED ANNUAL PRODUCTION EQUIPMENT: RACKING SYSTEM, ENGINEERING LEAKAGE 1'AiT15 AND/OP GPOUND FAULTS.° (NECE 6903nCF)) " DG GONDUGroRS flrHfR DO NOT ENTEP -Hf PUILDIN6 OP APf PUN IN METALLIC PACfWAYS OP ENCLOSURES 7-0 THE S-2 11, ALL PHOTOVOLTAIC MODULf5 AND A550CIATED EQUIPMENT AND WIPING MATERIAL SHALL Of PROTECTED FROM ANY FIPST AGGESS/PLf DG 0ISCONNEGTIN6 MEANS POP NEC 6903/ (f), LAMC 93,6903r (f) 4,400 kWh/Yr STAMP PHY5IGA1_ DAMAGE 34, ALL 17f-ALLIC FPAMf PAILS AND OTHEP CUPPFNT CAPPYIN6 MfTALUG COMPONENTS (GONOUIT JUNCTION ff PULL 12, ALL fIfC-PICAL DEVICES AND UTILIZATION fOUIPMENT SHALL Of L157_ED PY AN APPROVED7-f5-lN5 AGENCY. OOXfS, PACfWAY, E'rG) SHALL Of SOLIDLY 6POUNOED PEPTHF MANUFAC-UPFP'S 157-ALLATION 1N5-PUGTIONS LAr7G Drawing S-3 EQUIPMENT: RACKING SYSTEM, CLAMPS l3.OUTDOOPEQUIPMfNrSHAL-OfATLEASTNEMA3PRATED. 9A69o,1/O3ff93,11o.3(PJ. 14, ALL SPECIFIED WIRING l5 OA5ED ON THE U5f OF COPPfP NUT5, POLTS ff WA5HER5 THAT ATTACH fOUIPMENT GROUNDING LUGS SHALL Of 5TAINLf55 57_ffL LAtIC /5, GONTPAGTOP SHALL OOrAIN fLEGTPIGAL PfPMIr5 AND 5HALL GOOPDINATf ALL INSPECTION, COMMISSIONING AND 93.1 r03(0), NOTES, INDEX, SITE INFO, S-4 EQUIPMENT: RACKING SYSTEM, RAIL AGGfPTANGf WITH THE CLIENT UTILITY CO, AND Gl7Y INSPEGTOPS A5 NEEDED 36. NO PIPING, DUCT5 OP fOUIPMENr FOPEIGN 7-0 fLECTPIGAL fOUIPMENT SHALL Of PEPMITTED TO Of LOCATED WITHIN PROJECT DATA, CODE 16, DPAWIN65 APE DIAGPA17/1AT1G ONLY, POUTING OF PAGfWAYS SHALL PE AT -HE OPTION OF -Hf GONTPAG-OP UNLf55 -nf DEDICATED SPACE AOOVf THE fl-ECTM, fOUIPMENT. EQUIPMENT: RACKING SYSTEM, ENGINEERING OTHfkW15f NOTED AND SHALL Of GOOPDINATED WITH OTHfP TPADfS, 3-. ALL FIELD IN5TALLfD JUNCTION, PULL AND OUTLET OOXfD LOCATED PfHIND MOOULfS OP PANELS SHALL Of S-5 /1. IF DISTANGfS OF GAOLf PUN5 APF DIFFfPfN'T THAN SHOWN, THE GONTPAGTOP SHALL NOTIFY fLfGTRIGAL fN61NfFP AGGE55/DLE DIPEGTLY OP OY DISPLACEMENT OF A MODULE (5) OP PANEL (5J SECURED PY PEMOVAOLE FA577ENEPS. Sheet STAMP TO VALIDATE -Hf WIPE SIZE. FINAL DPANIN65 WILL Of PUP -LINED AND UPDATED AS APPPOPPIATE. 38. PEI70VAL OF A OWP-IN-EPAG-NE / ✓fP-fP OR OTHER EQUIPMENT SHALL NOT DlSCONNEC--Hf OONDING 18, WENfVfP A DlSGPEPANCY IN QUANTITY OF FOUIPMENr,, ARISES ON THE DPAWINGS OP SPfGIFIGATIONS, Tt f GONNEG-ION OfTWffN -Hf GPOUNPIN6 fLfG-PODf GONDUGTOP AND rHf PHOTOVOLTAIC 5OUPGf AND/OP OUTPUT EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC GONTRAGTORSHALLOfRf5PON5/OLfFOP PROVIDINGAND INSrALLINGALLMATERIALAND SfPVIGfSPEOUIPEDDYTHE GIPGUIrGPOUNDfDGONDUGTOP. S-G 57­P/C7­f5T CONDITION-5 NOTED ON rHf DP. AWING5 OP IN THE SPfCIFICATlONS TQ ENDUPE COMPLETE COMPLIANCE 39, -Hf POOF MOUNTED PHOTOVOLTAIC MODULfS, PANELS, OP 501.-AP VOL-AlG POLL POOFING l7A7_fPIAL SHALL HAVE ENGINEERING AND LONGEVITY OF THE OPEPAOLf SYSTEM PEOUIRED PY rHf APGHITEGT/ENGINEEP. THE SAME OP OCTTFP LISrfD FIPE-PF5I5TANGE PATINE THAN rHf PUILDING POOF-GOVfPIN6 MATEPIAL. l9. ALL PPOCHUP. E5, OPfRArION MANUALS, CA-AL065, SHOP DPANING5, M-C, SHALL Of HANDED OVEP TO THE OWNEP'S 40, ALL POOF MOUNTED GONOUIT WILL Of A MINIMUM I" OFF THE POOF SURFAGf A- 1 S-7 EQUIPMENT: RACKING SYSTEM, BILL OF MATERIALSRfPPESfNFATVfATTHE COMPLETION OPWORK. Cap A'1�1COf1C'S i a t809 37th Dr, nacortes, WA 98221 (E) UTILITY (NET) METER (E) MAIN SERVICE PANEL (INSIDE) AD � I � �XlSTW6 OPWWfiY Aw. C C 1 J�J L J -jai _ t 0 ARRAY 1 (13) HYUNDAI HiD-S320RG(BK) SOLAR MODULES (13) SOLAREDGE P340 DC/DC POWER OPTIMIZER *EVERY MODULE WITH 1 POWER OPTIMIZER =Zw PLOT PLAN Wlifl P00)" PLAN 1 SCALE: 1/16"= 1'-0" A-2 (N) SOLAREDGE SE5000H-US INVERTER (OUTSIDE) INTEGRATED DC DISCONNECT EQUIPPED WITH AUTOMATIC RAPID SHUTDOWN I. MR I I PROPERTY LINE (APPROXIMATE - NOT FOR LEGAL USE) 15. Know what's below. Call before you dig. SCALE: 1 /16"=1'-0" 0 8' 16' c 1 � r pc (IN FEET) ( 32' 2"X2" AHJ APPROVAL STAMP -�4� CAPSTONE SOLAR DESCRIPTION I DATE IREVISIONI INITIAL I 8.JUL., Solar Specialist TAYLOR DISCH System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43°/ 4:12 PITCH AZIMUTH 270° DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawina SITE PLAN Sheet A-2 1 POOH PLAW r1O0u1_f5 A-3 I SCALE: 1/8" = Y-0" (N) SOLAREDGE SE5000H-US INVERTER (OUTSIDE) INTEGRATED DC DISCONNECT EQUIPPED WITH AUTOMATIC RAPID SHUTDOWN (E) UTILITY (NET) METER (E) MAIN SERVICE PANEL (INSIDE) (N) (QTY: 26) ATTACHMENT POINTS, SPACED EVERY 48", LAG MOUNTED AND SEALED WITH CHEMLINK DURALINK 50 SEALANT, PER MANUFACTURER'S SPECIFICATIONS, TYP. ARRAY 1 (13) HYUNDAI HiD-S320RG(BK) SOLAR MODULES (13) SOLAREDGE P340 DC/DC POWER OPTIMIZER *EVERY MODULE WITH 1 POWER OPTIMIZER ro Know what's below. C8116efore you dig. Em 31'-11" 4' TYP. NOTE TO PV INSTALLERS -- I. ATTACHMENTS MUST BE INSTALLED PER MANUFACTURERS SPECIFICATIONS, REFER TO INSTALLATION GUIDE ON S-1. 2. LOCATE RAFTERS/TRUSSES LOCATIONS. 3. BACKFILL ALL PILOT HOLES WITH SEALANT. 4. ATTACHMENTS MUST BE LAG MOUNTED INTO RAFTERS/TRUSSES. 5. DRIVE LAG BOLT UNTIL ATTACHMENT IS FIRMLY IN PLACE. WHEN THE PROPER TORQUE IS REACHED, THE EPDM RUBBER BACKING ON THE SEALING WASHER SHOULD EXPAND BEYOND THE EDGE OF THE METAL WASHER. DO NOT OVERTIGHTEN. 6. INJECT CHEMLINK DURALINK 50 SEALANT INTO PORT UNTIL SEALANT EXITS BOTH VENTS. ueu o 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1 0 U F=_1 0 1 0 0 1 0 3' TYP. 3' TYP. 17-11 FIRE SETBACK, TYP. MOUNTING CALCULATIONS A MOUNTING SYSTEM AND MANUFACTURER UNIRAC SOLARMOUNT FLUSH B TOTAL WEIGHT OF MODULES, RAILS, ATTACHMENTS, & OPTIMIZERS 643.2 LBS MODULE WEIGHT 140.1) X NUMBER OF MODULES 13 521.3 LBS OPTIMIZER WEIGHT (1.4) X NUMBER OF OPTIMIZERS 13 18.2 LBS RACKING COMPONENTS 121.9 LBS C ATTACHMENTS WEIGHT (1.8) X NUMBER OF ATTACHMENTS 26 46.8 LBS D WEIGHT PER ATTACHMENT POINT (B/C) (POINT LOAD) NOT TO EXCEED 45 LBS 2T7 LBS E MAXIMUM RAIL CANTILEVER 16 IN F TOTAL SURFACE AREA OF PV MODULES 17.88 SO FT X MODULES 232A SO FT G DISTRIBUTED WEIGHT OF PV MODULE ON ROOF (B/F) (DEAD LOAD) 643.24 LBS / 232.4 SO FT 28 PSF SOLADECK JUNCTION BOX, TYP. ELECTRICIAN TO DETERMINE FINAL JUNCTION BOX LOCATIONS IN FIELD CONDUIT 3/4", TYP. ELECTRICIAN TO DETERMINE FINAL CONDUIT LOCATIONS IN FIELD SCALE: 1 /8"=1'-0" 0 4' 8' (IN FEET) 16' 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION DATE IREVISIONI INITIAL 8.JUL.2021 I 1 Solar Specialist TAYLOR DISCH System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43°/ 4:12 PITCH AZIMUTH 270° DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing PV LAYOUT AND COMPONENT LOCATION Sheet A-3 CONDUIT WIRE RATING DERATE FOR TEMPERATIRE ISC WIRE VOLTAGE DROP CALCULATIONS RUN LENGTH AMPS VOLTAGE DROP VOLTAGE DROP % VOLTAGE AT LOAD 2"X2" AHJ APPROVAL STAMP A Y4" PVC SCHEDULE 40 CONDUIT (3) 8 AWG THHN (Black, Red, White) (1) 8 AWG Cu Bond Conductor (Green or bare) 8 AWG RATE 90"C =SSA TEMPERATURE DE -RATING @ 104`F = 0.91 SSA x 0.91 = SO.OSA ISC x 1.25 x 1.25 = 15 52A 8 AWG OK IAW NEC 690.8 (B)(1) 2 x 12.9 x 50' = 1290 x 25A = Vd = 16510 Z.34 volts 50 25 1.95 0.81 238.05 IF 1-WAY LENGTH OF CIRCUIT EXCEEDS 50' RECALCULATE Vd TO VERIFY LIMITS B Y /" EMT CONDUIT (2) 10 AWG THHN (Positive, Negative) III 8 AWG ct Bond Conductor (Green or bare) 10 AWG RATE 90°C = 30A TEMPERATURE DE -RATING @ 104°F = 0.91 30A x 0.91 = 27.3A ISC x 1.25 x 1.25 = 15.52A 10 AWG OK IAW NEC 690.8 (B)(I) 2 x 12.9 x 50' = 1290 x 15A _ Vd = 10380 - 1.86 volts 50 15 1.86 0.78 238.14 IF 1-WAY LENGTH OF CIRCUIT EXCEEDS 50' RECALCULATE Vd TO VERIFY LIMITS C PV WIRE IN FREE MINIMUM 1 OAWG Cu POSITIVE, BARE Cu EGC OR AIR OR THHN IN (90° RATED) WIRE NEGATIVE INSULATED EGC IN CONDUIT CONDUIT CONTROLLED CONDUCTORS ARE LIMITED TO: (1) STRING OF (1 3) HYUNDAI HID-S320RG(BIO MODULES NOT MORE THAN 30 VOLTS AND 240 VOLTAIMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION OUTSIDE THE ARRAY. SOIarEdge Power Optimizer P340 CONNECTED IN SERIES UTILITY METER NOT MORE THAN 80 VOLTS AND 240 VOLTAMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION DC Input Power: 340 watts BI-DIRECTIONAL (NET) INSIDETHEARRAY. Maximum Input Voltage- 48 Vdc THE RAPID SHUTDOWN INITIATION IS PERFORMED BY EITHER DISCONNECTING THE AC FEED TO THE INVERTER, M PPT Range- 8 to 48 Vdc CL 200, FMZS, 60Hz OR - IF I g Al2 THE INVERTER DC SAFETY SWITCH IS READILY ACCESSIBLE - BY TURNING OFF THE DC SAFETY SWITCH. Maximum Short Circuit Current (ISC). 1 1 AdCO O O 1-PHASE, 3W, 1 ZO/Z40V 12 13 METER #: H56719189 Maximum Output Current: 15 Adc per stringOOFTOP PV CONDUCTORS TO BE I" PHOTOVOLTAIC SYSTEM EQUIPPED WITH ABOVE ROOFTOP AND PROTECTED Maximum Output Voltage: 60 VdcFROM PHYSICAL DAMAGE VIA INVERTER -EMBEDDED AUTOMATIC, RAPID SHUTDOWN Limitations: 8 to 25 Optimizers per stringSECUREMENT WITHIN ARRAY + - + - Maximum Power Per String: 6000WBOUNDARY OR 3/4" CONDUIT. O CAPST NE SO L A R` DESCRIPTION DATE REVISION INITIAL 8.JUL.2021 1 ALL ELECTRICAL MATERIALS & EQUIPMENT SHALL BE LISTED BY APPROVED TESTING LAB JUNCTION BOX DC DC IOOOV NEMA 3R,UL LISTED OR O O O DC DC APPROVED EQUALA G EC + - + - Solar Specialist TAYLOR DISCH El E Z P 30A PV AC System Engineer TIM WACHTMAN BREAKER N PV WIRE IN FREE AIR OR THHN IN CONDUIT B MINIMUM IOAWG Cu (90' RATED) WIRE POSITIVE, NEGATIVE �_�Zcc BARE Cu EGC OR INSULATED EGC IN CONDUIT e MAXIMUM 2% VOLTAGE DROP System Designer CASEY MILLER Customer Info JEN BOWMAN / \v, 3809 37TH DR 809 G ELECTRICAL INSTALLATIONS ANACORTES, WA 98221 PARCEL#: P80341 O + WILL COMPLY WITH THE + REQUIREMENTS OF THE Project Details 4.16 KW ROOFTOP PV D ^ O N.E.C. SEC 690 & 705 I (v' - Note: 705.31 Note: 705.12)B)121(3)(b) C SYSTEM SOLAREDGE SE5000H-US Note: 312.6 & 312.8(A)I 1) & (2) Note: 404.6 Exception MAIN SERVICE OUTPUT: Z ]A @ 240V Note: 230.66 & 230.70(C) PANEL NEMA 3R, UL LISTED, Note: 310.15)3)1c) INTERNAL GFDI Note: 250.24)B) 200A BUSBAR Note: 314.16 200A MAIN OCPD INTEGRATED DC Note: 690.12)C) DISCONNECT WITH RAPID TILT 18.43'/ 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16 kW SHUTDOWN KIT AC SYSTEM RATING 5.0kW Module Information Inverter Specifications Conductor Calculation Interconnection Method ESTIMATED ANNUAL PRODUCTION PV MODULE: HYUNDAI HiD-S320RG(BK) SOLAREDGE SE5000H-US MAX BRANCH DC CONDUCTOR AMPACITY: 320W x 13=4160W / 380V=10.95Ax 1 25%=13.14A SOLAR CIRCUIT CONNECTED INTO EXISTING 200A MAIN SERVICE PANEL WITH NEW 2P30A SOLAR 4,400 kWh/Yr Drawing ELECTRICAL DATA PER MODULE (STC): MAXIMUM POWER - Pmax (Wp): 320 MAXIMUM POWER VOLTAGE -Vmpp (V): 33.7 MAXIMUM POWER CURRENT - Impp (A): 9.57 OPEN CIRCUIT VOLTAGE - Voc (V): 40.6 SHORT CIRCUIT CURRENT Isc (A): 10.04 MODULE EFFICIENCY: 18 3% RATED/MAXIMUM AC POWER OUTPUT: 21 A MAX. CONTINUOUS OUTPUT CURRENT: Z 1 A MAX.DC INPUT POWER: 7750@240V MAX. INPUT VOLTAGE: 480V NOMINAL DC INPUT VOLTAGE: 380V MAX. INPUT CURRENT: 13.5A@Z40V CEC WEIGHTED EFFICIENCY: 99% 0 MAX. EFFICIENCY: 99.Z/o P340 MAXIMUM OUTPUT CURRENT = 15A 10 AWG Cu 90' RATED=40A(.91)=36.4A(1)=36.4A 36AA>! 13.14A OK TO INSTALL IAW NEC 690.8(B)(1-2) MAX BRANCH AC CONDUCTOR AMPACITY: 25A MAXIMUM CONT. OUTPUT CURRENT 25A x 125%=31.25A 8 AWG Cu 90°=55A x .91=50.05A x 1=50.05A 50.05A >! 31.25A OK TO INSTALL IAW NEC 690.8(B)(1-2) (OCPD) BREAKER OCPD TO BE INSTALLED AT OPPOSITE END OF BUSBAR FROM OCPD PROTECTING THE BUSBAR NEC 705.12(B)(3)(2) 200A RATED BUSS x 120%= 240A- 200A MAIN OCPD = 40A 2P30A BREAKER OK INSTALL PERMANENT LABEL ADJACENT TO THE BACK -FED BREAKER WITH FOLLOWING OR EQUIVALENT WORDING: WARNING: POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. ELECTRICAL LINE DIAGRAM Sheet E 1 UTILITY/ AHJ (PHENOLIC) NEC 705.12(B)(3) NEC 690.56(C)(1)(a) NEC 705.12(B)(3) AS REQUIRED IF PV INTERCONNECTION IS MADE TO SUPPLY SIDE OF SERVICE DISCONNECT r � • POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN UTILITY NET METER ❑■ DC SOLAR DISCONNECT 0 SERVICED BY QUALIFIED PERSONNEL ONLY NEC 690.31(G)(3) & (4) NEC 690.56(C)(3) SYSTEM DC CIRCUIT CONDUCTORS. EXPOSED RACEWAYS, CABLE TRAYS & OTHER WIRING METHODS. COVERS OR ENCLOSURES OF PULL BOXES & JUNCTION BOXES. CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION. REFLECTIVE WITH %" UPPERCASE, WHITE ON RED. EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE MORE THAN 10' hDl7D5Nf FAS7-,ffN)ffD 516N5; - TYIf LAffl- 5Yl/LL 1Pf 5Ul -AOI-f /=OP TYIf fW/P0Nl7,ffNT WYIf,P)f1T l5 /NSThLL)fD, - WYI)ffKf PfOUIPff) EL5EWtffPf IN TYllS CODE, /ILL FlfLD L-IJOEL5, WAPNIN65, ANO MAPKIN65 5Y10UL0 COMPLY WIT-" A 5/ Z535.4 [NEC 110,21C13J I IfLD MAPK/N61. -f1DYlf5Nf FA5T-,ffNf0 5/GN5 MAY Of ACGEPTf1DLf 11 PPOPEKLY A011fPEP, VINYL 5/6N5 SY AI-L- I3f WffA7-tlf ? 1'f5/S7-hN7- CIPG 605J/157 1, i}LL EQUIPMENT TO OE LISTED 1OY UL OP OTIIEP NPTL, /}NO L-AffLED POP l7-5 /}PPLIC/ ITION, Z, /}LL CONOUCTOPS SHALL OE COPPff, P/fiT�D FOP 600 V AND 90 DEGP�,ff C WET ,ffNVIPON1 I,ffNT, 3, WIPING, CONDUIr, ANO PACEWAY5 MOUNTEO ON POOI=TOP5 ShftLL OE POUTED OIPECTLY 7-01 ANO LOCt1T,E0 A5 CL05E /15 P055/IOL,ff TO Trtf N,ff/}P,ffST PIOGff, MP, OP V&L -EY, 4, WOPKING CL,ff/1P/WCffS /}POUND ALL- NSW ANO EX157-1NG ffL,ffCTPICAL- 4OUIPMGNT St7/fLL COMPLY Wlii> NBC 110,Z6, 5, DPAWING5 INDICAT-E TlIf GENEPAI - /IPPANGEMENT OF 5Y5T�M5, CONTP/ICTOP ShfILL FUPNI511 fILL NECE55APY OUTLETS, 5UPPOPTS, FtrT-INGS ANO TO FULF1,LL /1PP7-lC/i1OLE GOD)fS AND 57-/1NOAPDS, 6, WYtffP)f 5/ZE5 OF JUNCTION 1OOXE5, PACffWAYS, /WO CONDUITS APB NOT SP GI> l D, Thf GONTPACT-OP 5t1&-L 5/ZE ThEM hGGOP0/N5LY, 1, ALL WIPE T PMINftTlONS ShttLL OE /IPPPOPP1A7-fLY Lt}IO,ffLED AND Plff/}DILY V15/1OLE, 8, MODULE GPOUNOING CLIPS TO PE IN57-ftLLED PfTWffffN MODULE FP/YM,ff ANO MODULE 5UPPOPT PAIl -, PEP 7-11E GPOUNDING CLIP MANU1 ACTOPEP'5 /NSTPUCTION, 9,1 IODULf 5UPPOPT P/ - TO PE OONOEO TO CONTINUOUS COPPEP Gf,C, VIA WffO LUG OP 1L5GO G01--4007-LAY-IN LUG, 10, T1ff POLAPITY OF T-11f GPOUNDffD GONDUCTOPS l5 NEG/ITIVf 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IREViSION1 INITIAL I 8.JUL.2021 I 1 I Solar SDecialist I TAYLOR DISCH Svstem Enaineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43' / 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing LABELING INFORMATION Sheet E-2 HYUNDAI SOLAR MODULE RGMono -Crystalline Type HiD-S310RG(BK) HiD-S3151113(13K) HiD-S320RG(BK) BLACK D ■�■ PERC Technology PERC technology provides ultra -high efficiency with better performance in low irradiation. Maximizes installation capacity in limited space. Lbl� Reliable Warranty HYUNDAI Global brand with powerful financial strength provide reliable 25-year warranty. Hyundai's Warranty Provisions 0R, 12-Year Product Warranty On materials and workmanship 25 • 25-Year Performance Warranty v6Aas Initial year: 97% Linear warranty after second year: with 0.7%p annual degradation, 80% is guaranteed up to 25 years Certification e ul us ILV USTEe www.hyundal-es.co.kr ♦ I Anti -LID / PID Both LID(Light Induced Degradation) and PID(Potential Induced Degradation) are strictly eliminated to ensure higher actual yield during lifetime. NH3 NaCI Corrosion Resistant Various tests under harsh environmental conditions such as ammonia and salt -mist passed. About Hyundai Energy Solutions XS�ndai Ce7j • • I Q 9sss�mbled nJ� rive T'i t Mechanical Strength Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow and strong wind. QQ UL / VDE Test Labs Hyundai's R&D center is an accredited test laboratory of both UL and VDE. Established in 1972, Hyundai Heavy Industries Group is one of the most trusted names in the heavy industries sector and is a Fortune 500 company. As a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth engine by developing and investing heavily in the field of renewable energy. As a core energy business entity of HHI, Hyundai Energy Solutions has strong pride in providing high -quality PV products to more than 3,000 customers worldwide. UL 1703-3rd Edition - Flat -Plate Photovoltaic Modules and Panels A HYUNDAI ENERGY SOLUTIONS Printed Date: 052020 Electrical Characteristics 310 40.3 9.94 315 40.5 G 00 33.1 33.4 9.45 9.51 6.25", mono -crystalline silicon 1,000 -0.391 _n a, Mechanical Characteristics 1,007 mm(39") x 1,681 mm(66") x 33 mm(1.3") 18.2 kg (40.1lbs) 60 cells in series (6 x 10 matrix) (Hyundai cell) 4 mm2 (12AWG) cables with polarized weatherproof connectors, IEC certified (UL listed), Length 1.0 In (39A) IP65, weatherproof, IEC certified (UL listed) 3 bypass diodes to prevent power decrease by partial shade Front Glass: Anti -reflection coated glass, 3.2 mm (0.126") Encapsulant : EVA I Back Sheet: Weatherproof film Clear anodized aluminum alloy type 6063 (Black color) Module Diagram (unit:mm) Mono -Crystalline Si Type -Front Side View 4.32 (109.65) 7.12 (180.85) 0 0 0 d 11.44 (290.5) Sales &Marketing Prin[edonFSCcerdSed ero-filendlyPaPer. Sales@hyundai-es.co.kr PSC 1.30 320 40.6 10.04 33.7 9.57 U.UJ 1 'All data at STC (Standard Test Conditions). Above data may be changed without prior notice. Installation Safety Guide Only qualified personnel should install or perform maintenance. • Be aware of dangerous high DC voltage. • Do not damage or scratch the rear surface of the module. • Do not handle or install modules when they are wet. Nominal Operating 46°C t 2 Cell Temperature Operating Temperature -40 - 85'C Maximum System Voltage DC 1,000V Maximum Reverse Current 20A I-V Curves Current [Al 10 s 8 6 5 4 InOitl. Imetl=1,000W/m� 3 —Operating Cell Temp=5°C 2 —Operating Cell Temp=25°C — Operating Cell Temp = 45°C 1—Operetiig CHlTemp=65°C 0 0 5 10 15 20 25 30 35 40 45 Voltage [ V I Current [A] 12 Cell temp. 10 =25°C —Imdd. Ind =1,000w/m' 8 — lurid. Iliad = 80111l 6 —l0pid. Ind -6001l 4 ould now — Ipcid. ind = NOW ° 0 10 20 33 40 Voltage[ V A&HYUNDAI ENERGY SOLUTIONS Printed Date :05/2020 2 "X2 AHJ APPROVAL STAMP CAPST°NE SOLAR DESCRIPTION I DATE REVISION INITIAL I 8.JUL.2021 I I Solar Specialist TAYLOR DISCH Svstem Enaineer TIM WACHTMAN �ysrem uesigner CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4,16KW ROOFTOP PV SYSTEM TILT 18.43°/ 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: PV MODULE SPECIFICATION SHEETS Sheet E-3 Single Phase Inverter z with HID -Wave Technology m for North America X SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE1000OH-US / SE1140OH-US _ I..'..' O V1 J U p o solar _HD, ,,. ® o solar. e: _HD rJ r s r O O O � O O O p O Optimized installation with HD -Wave technology / Specifically designed to work with power optimizers / Record -breaking 99%D weighted efficiency / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 solaredge.com / UL1741 SA certified, for CPUC Rule 21 grid compliance / Small, lightweight, and easy to install both outdoors or indoors / Built-in module -level monitoring / Optional: Faster installations with built-in consumption metering (1%D accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. _ ✓ _ ✓ _ _ ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.511) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VI2I 8.5 10.5 1 13.5 1 16.5 20 1 27 30.5 Adc Maximum Input Current @208VI4 - 9 1 - 1 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(') Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety U111741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to TILL. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) (-40°F / -40°C option)() T / °C Protection Rating NEMA 4X (Inverter with Safety Switch) n) For other regional settings please contact SolarEdge support A higher current source may be used; the inverter will limit its input current to the values sated solar =se Revenue grade inverter P/N SExmH-USOOONNC2NC2 I°I For power de -rating information refer to: https://wwwsolaredge.com/sites/defaulVfiles/se-temperature-Berating-note-na.pdf Ia -40 version P/N: SExxxxH-US000NNU4 ® SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2019N01/ENG NAM. Subject to change without notice. ROHS 2"X2° AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE REVISION INITIAL I 8.JUL.2021 I I Solar Specialist TAYLOR DISCH Svstem Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43° / 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16WV AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: INVERTER SPECIFICATION SHEETS Sheet E-4 Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization solaredge.com / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solar =@@ / Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P485 / P505 u.I11j111 Rated Input DC Power°I 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125111 832 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 01 Vdc Optimizer 1 ± STANDARD COMPLIANCE EMC Material ROHS INSTALLATION SPECIFICATIONS FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 IEC62109-1 (class II safety), UL1741 UL94 V-0, UV Resistant Yes Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129x153x33.5/ 5.1x6x1.3 129x159x49.5/5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm /in Weight (including cables) 630 / 1.4 1 750 / 1.7 845 / 1.9 1064 / 2.3 gr/ lb Input Connector p MC4131 Single or dual MC4tax41 MC4(1) Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9/2.95 1.2/3.9 1 1.2/3.9 1 1.2/3.9 1.2/3.9 m/ft Operating Temperature Range") -40 - +85 / -40 - +185 'C /'F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % m Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power'. Modules with up to +5% power tolerance are allowed NEC 2017 requires max input voltage be not more than 80V m For other connector types please contact SolarEdge w For dual version for parallel connection of two modules use the P485. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer Is, For ambient temperature above +85°C / +185'F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details. Minimum String Length P320, P340, P370, 8 10 18 P400 (Power Optimizers) P405, P485, P505 6 8 14 Maximum String Length 25 25 50j81 (Power Optimizers) 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 60000) 1275001) us) Parallel Strings of Different Lengths Yes or Orientations IG For detailed string sizing information refer to: http://w ..solaredge.com/sites/default/files/string_sizing_na.pdf m It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400 in one string w A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement re For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W m For 277/480V grid: it is allowed to install up to 17,550W per string when the maximum power difference between each string is 2,000W 2"X2° AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IREViSION INITIAL I 8.JUL.20. 1 Solar Specialist TAYLOR DISCH Svstem Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43' / 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr W Drawing EQUIPMENT: DC/DC POWER OPTIMIZER SPECIFICATION SHEETS Sheet ® SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. CC �us Ro H S All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2019NO2/ENG NAM. subject to change without notice. Intertek E-5 PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085DI FLASHLOC COMP KIT DARK, 20 PACK 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT SS SERRATED FLANGE NUT FLASHLOC BASE MILL OR DARK iiM U N I RAC' PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ,~ ALL DIMENSIONS ARE DRAWING TYPE: PART DRAWING NOMINAL Q 1411 BROADWAY BLVD. NE ' ALBUQUERQUE, NM 87102 USA DESCRIPTION: FLASHLOC COMP KIT PRODUCT PROTECTED BY ILL PHONE: 505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 4/28/2020 LEGAL NOTICE SHEET FLASH LOC :: UNIRAC BETTER SOLAR STARTS HERE FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all -in -one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC's patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don't just divert water, LOC it out! FA CNAwayviex FWA—Vi, PROTECT THE ROOF LOC OUT WATER HIGH-SPEED INSTALL Install a high -strength waterproof attachment With an outer shield E contour -conforming gasket Simply drive lag bolt and inject sealant into the port SEALANT without lifting, prying or damaging shingles. and pressurized sealant chamber Othe Triple Seal to create apermanent pressure seal . technology delivers a 100%waterproof connection. FLASH LOC INSTALLATION GUIDE :UNIRAC4 BETTER SOLAR STARTS HERE PRE -INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4" below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32" pilot hole. Clean roof surface of dirt, debris, snow, and ice. Next, BACKFILL ALL PILOT HOLES WITH SEALANT. NOTE: Space mounts per racking system install specifications. STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down -slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. USE ONLY UNIRAC APPROVED SEALANTS: Chemlink Duralink 50, Chemlink MA Geocel4500, or Geocel S-4 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION DATE REVISION INITIAL 8.JUL.2021 I I Solar SDecialist I TAYLOR DISCH Svstem Enaineer TIM WACHTMAN ,ysrem ueslgner CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43"/ 4:12 PITCH AZIMUTH 270° DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawina EQUIPMENT: RACKING SYSTEM, ROOF ATTACHMENT Sheet S.1 Intertek Total Quality. Assured. U-N11RAC, INC. - IM _ A D TEST REPORT SCOPE OF WORK TAS 100(A) TESTING ON FLASHLOC, ROOF MOUNTS REPORT NUMBER K1187.01-109-18 TEST DATE(S) 09/09/19 ISSUE DATE REVISED DATE 09/24/19 09/24/19 RECORD RETENTION END DATE 09/09/29 MIAMI-DADE COUNTY NOTIFICATION NO. ATI 19048 LABORATORY CERTIFICATION NO. 18-0524.13 PAGES 18 DOCUMENT CONTROL NUMBER ATI OD651(08/21/17) RT-R-AMER-Test-2816 _ © 20171NTERTEK . tnt` rt` kIII Court York, Pennsyaania 1]4 myh,amry 7406 Total Quality. Assured. Telephone: 717-764-7700 F.ednnile: 717-764-4129 www.intertek.com/building TEST REPORT FOR UNIRAC, INC. Report No.: K1187.01-109-18 Revision 1: 09/24/19 Date: 09/24/19 UNIRAC, INC. 1411 Broadway Blvd. NE Albuquerque, New Mexico 87102-1545 SECTIL,N 1 SCOPE Intertek Building & Construction (B&C) was contracted by Unirac, Inc. to perform TAS 100(A) testing in accordance with Miami -Dade County requirements on their FLASHLOC, Roof Mounts. Results obtained are tested values and were secured by using the designated test method(s). Testing was conducted at the Intertek B&C test facility in York, Pennsylvania. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. s 1'C °CUrro,,,i A�G e •.9 acl.. • • No. 83035 29: : 1 AQa. STATE OF .T(� For INTERTEK B&C: aNA `gN���• COMPLETED BY: Robert J. Beatty Daniel C. Culbert, P.E. Technician — TITLE: Product Testing Senior Project Engineer SIGNATURE: DATE: 09/24/19 �D 09/24/19 RIB:wnI 2019.09.25 09:59:46-04'00' This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and Its Client. Intertek's responsiblllty and liability are limited to the terms and Conditions of the agreement. Intertek assumes no liability to any paM, otherthan tothe Client m accordance with the agreement, for any loss, espense or damage occasioned bythe use of this report. Only the olent is authorized to permit copying or distribution of this report and then only In its entirety. Any use of the Intertek name or e of Its marks for the sale or advertisement ofthe tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample(s) tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certaication program. version: 08/21/17 Page 2 of 18 RT-R-AMER-Test-2816 Intertek Total Quality. Assured. TEST REPORT FOR UNIRAC, INC. Report No.: K3187.01-109-18 Revision 1: 09/24/19 Date: 09/24/19 Test Specimens #3 and #4 with M-1e sealant T.... o.......1...... rLe..,v..a....ee.1:..«e..,�I...,e.a ....,d,wed �. p,.u,...... 130 Derry Court York, Pennsylvania 17406 Telephone: 717-764-7700 Fawimile: 717-764-4129 www.im—k.mm/building Interval No. Wind Speed (mph) Time (min) Water Spray 1 35 15 On 2 0 5 Off 3 70 15 On 4 0 5 Off 5 90 15 On 6 0 5 Off 7 110 5 On 8 0 5 Off Tcct Rccrrltc• Th. TAC innfAl tact rccii ltc arc ac fnllnwc- Wind Speed Results Allowed 35 mph 0 oz. N/A 70 mph 0 oz. N/A 90 mph 0 oz. N/A 110 mph 0 oz. N/A Total 0 oz. 13.6 oz. Results: Pass General Note: Each configuration was evaluated separately with no leakage at the mount locations during or after the test. version: 08/21/17 Page 6 of 18 RT-R-AMER-Test-2816 2"X2" AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION DATE REVISION INITIAL 8.JUL.2021 1 Solar Specialist TAYLOR DISCH System Engineer TIM WACHTMAN ,ysrem ueslgner CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43'/ 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, ENGINEERING STAMP Sheet S-2 PART # TABLE P/N DESCRIPTION 302045M UNIVERSAL AF MID CLAMP - MILL 302045D UNIVERSAL AF MID CLAMP - DRK 302050M UNIVERSAL AF END CLAMP - MILL 302050D UNIVERSAL AF END CLAMP - DRK UNIVERSAL END CLAMP d:UNIRAC 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW,UNIRAC.COM UNIVERSAL MID CLAMP UNIVERSAL AF END CLAMP 30mm to 46mm z MODULE FRAME PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY DESCRIPTION: UNIVERSAL AF CLAMPS LREVISION DATE: 9/28/2020 UNIVERSAL AF MID CLAMP 30mm to MODULE FRAME DRAWING NOT TO SCALE ALL DIMENSIONS ARE m .� NOMINAL Q PRODUCT PROTECTEJBY ONE OR MORE US PATLEGAL NOTICESHEET 2"X2" AHJ APPROVAL STAMP CAPST°NE SOLAR DESCRIPTION I DATE IREViSION INITIAL I 8.JUL.2021 I Solar SDecialist I �TAYLOR DISCHDISCH SvstemSvstem Ennineerr TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43°/ 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, CLAMPS Sheet S-3 BONDING SPLICE BAR 0 1 %" O O 0 � 15/16 411 TYPICAL SPLICE BAR DETAIL 12 n TYPICAL EXPANSION JOINT DETAIL PART # TABLE P/N DESCRIPTION 303019M BND SPLICE BAR PRO SERIES MILL 303019D BND SPLICE BAR PRO SERIES DRK 311111 RAC 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE; 505.242.6411 WWW.UNIRAC,COM PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY DESCRIPTION: BONDING SPLICE BAR PRO SERIES REVISION DATE: 8/23/2018 5/16"-18 TYPE F THREAD CUTTING SCREWS INCLUDED JOTS THAT ONLY 2 SCREWS ARE USED AT AN EXPANSION JOINT. THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. SEE INSTALLATION GUIDE FOR INSTRUCTION. DRAWING NOT TO SCALE ALL DIMENSIONS ARE Ln NOMINAL a c�I� PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET %" BOLT LOCATION —\ %" BOLT LOCATION PART # TABLE P/N DESCRIPTION LENGTH 320132M SM RAIL 132" MILL 132" 310132C SM RAIL 132" CLR 132" 320168M SM RAIL 168" MILL 168" 310168C SM RAIL 168" CLR 168" 320168D SM RAIL 168" DRK 168" 320208M SM RAIL 208" MILL 208" 310208C SM RAIL 208" CLR 208" 320240M SM RAIL 240" MILL 240" 310240C SM RAIL 240" CLR 240" 310240D SM RAIL 240" DRK 240" UNIRAC 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM 2 Y/ 6„ PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART DETAIL DESCRIPTION: STANDARD RAIL REVISION DATE: 9/11/2017 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL a CA PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET 2 "X2 AHJ APPROVAL STAMP CAPSTONE SOLAR DESCRIPTION I DATE IREVISION1 INITIAL I 8.JUL.2021 I I I Solar SDecialist I �TAYLOR DISCHDISCH SvstemSvstem Ennineerr TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PAWE1F#:P80341 Project Details 4.16KW ROOFTOP PV SYSTEM TILT 18.43° / 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, RAIL Sheet S-4 P7 structural ENGINEERS April 28, 2020 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05, ASCE/SEI 7-10, ASCE/SEI 7-16 2. 2006-2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017 3. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 5. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where "L" is the span noted in the U-Builder online tool. Clearance: 2" to 10" clear from top of roof to top of PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961 .3965 www.pzse.com 1 of 2 P7 structural ENGINEERS Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor YE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. —Structural Engineers Roseville, CA EXPIRES OS': 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com 2"X2" AHJ APPROVAL STAMP CAPST°NE SOLAR DESCRIPTION I DATE IREViSIONI INITIAL I 8.JUL.2021 I I I Solar SDecialist I TAYLOR DISCH Svstem Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 9822 1 PARCEL#: P8034 I Project Details 4.16KW ROOFTOP PV SYSTEM TILT 18.43' / 4:1 Z PITCH AZIMUTH 270' DC SYSTEM RATING 4.16 kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, ENGINEERING STAMP 2 of 2 Sheet S-5 ENGINEERING REPORT Plan review Distributed Dead Load 2.69 psf Average Roof Point Dead Load 22.32 Ibs TOTAL NUMBER OF MODULES 13 TOTAL KW 4.16 KW TOTAL AREA -232 ft2 Loads Used for Design BUILDING CODE ASCE 7-10 BASIC WIND SPEED 110.00 mph GROUND SNOW LOAD 25.00 psf SEISMIC (SS) 1.08 ELEVATION 482.00 ft WIND EXPOSURE B Loads Determined by Zip 98221 CITY, STATE Anacortes, WA BASICWIND SPEED 110.00 mph GROUND SNOW LOAD 0.00 psf Inspection PRODUCT MODULE MANUFACTURER MODEL MODULE WATTS MODULE LENGTH MODULE WIDTH MODULE THICKNESS MODULE WEIGHT EXPANSION JOINTS RAILS DIRECTION BUILDING HEIGHT ROOF TYPE RAFTER SPACING TOTAL WEIGHT SOLARMOUNT FLUSH Hyundai 13 - H i D-S320 RG(B K) 320 watts 66.00" 39.00" 1.30" 40.10 Ibs Every 40' EW 30.00 ft Shingle 24.00" 625.04 Ibs Roof Area 1 / Roof Area 1 - Array 1 Portrait Modules - Rails Running Across Slope SOLARMOUNT STANDARD RAIL ZONE ZONE ZONE SPANS [IN] DESIGN SPAN 48 48 48 Max Cantilever 16 16 16 Max Span 108 108 91 DESIGN PRESSURES [PSF) ZONE 1 ZONE 2 ZONE 3 Up -8.8 -17.6 -27.6 Down 18.9 18.9 18.9 Downslope 6.2 6.2 6.2 Lateral 1.8 1.8 1.8 MAXIMUM POINT LOADS[LBS] ZONE ZONE ZONE Up -96.8 -193.6 -303.6 Down 207.9 207.9 207.9 Downslope 68.2 68.2 68.2 Lateral 19.8 19.8 19.8 Tributary Area [ft2] 11.0 11.0 11.0 ROOF PITCH: 23° 2"X2" AHJ APPROVAL STAMP CAPST°NE SOLAR DESCRIPTION I DATE REVISION INITIAL I 8.JUL.2021 I Solar Specialist TAYLOR DISCH System Engineer TIM WACHTMAN System Designer CASEY MILLER Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW ROOFTOP PV SYSTEM TILT 18.43° / 4:12 PITCH AZIMUTH 270' DC SYSTEM RATING 4.16 kW AC SYSTEM RATING 5.0kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC ENGINEERING Sheet S-6 2"X2" AHJ APPROVAL DETAILED PARTS DESCRIPTION Qn STAMP Rail 310168D SM RAIL 168" DRK aluminum extrusion containing slots that accept module and roof attachment 8 i0pStructural / hardware, electrical bonding accessories, and splice bars. Splice 303019D END SPLICE BAR PRO SERIES DIRK 2 CAPSTONE Dark anodized aluminum extrusion forjoining adjacent lengths of rail to one another. S O L A R° Includes pre -assembled bolts. Uses 1/2" socket for 1-tool system install. DESCRIPTION DATE RE INITIAL 8.JUL.2021 Mid Clamp 302045D UNIVERSAL AF SERIES MID CLAMP DARK 20 Universal Aesthetic Fastener (Mid), Universal for modules between 30-46mm and features twist and lock installation, 1 tool install, UL2703 integrated bonding, and low profile hardware and 1/2 module gap for optimal aesthetics. Made from Aluminum and Stainless Steel hardware. Solar Specialist TAYLOR DISCH 49 End Clamp 302050D UNIVERSAL AF SERIES END CLAMP DARK 12 System Engineer TIM WACHTMAN Universal Aesthetic Fastener (End), Universal for modules between 30-46mm without the use of spacers or extra parts, Features twist and lock installation, 1 tool install, UL2703 System Designer integrated bonding, and low profile hardware for optimal aesthetics. Clamps can be placed anywhere on the rail and rail can be cut flush with the clamp for optimal aesthetics. Made CASEY MILLER from Aluminum and Stainless Steel hardware, Caps are PC/ASA. Customer Info JENNIFER BOWMAN 3809 37TH DR Microinverter Mounting 008013S MICRO MNT BND T-BOLT 1/4in x 3/4in SS 13 Attaches micro -inverter flange to beam using 3/4" x 1/4" bonding T-Bolt. ANACORTES, WA 98221 PARCEL#:P80341 Project Details 4.16 KW Grounding Lug (Weeb) 008002S GROUND WEEBLUG #1 3 ROOFTOP PV SYSTEM For electrical bonding of PV modules and rails. Accepts one 14AWG to 6AWG or two 12 AWG to 10 AWG copper wires. Tin plated copper body, 1 /4" stainless steel fasteners. TILT 18.43°/ 4:12 PITCH AZIMUTH 270° Flashing 004085D FLASHLOC COMP KIT DIRK 26 DC SYSTEM RATING FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all -in -one mount installs fast and looks great with dark anodized finish. Simply drive the lag 4.16 kW bolt and inject sealant into the base. FLASHLOC's patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with AC SYSTEM RATING 5.0 kW lag bolts, sealant, and hardware for maximum convenience. ESTIMATED ANNUAL PRODUCTION Conduit Mount 00802CM E-BOSS CONDUIT MOUNT COMP KIT 5 4,400 kWh/Yr 0 Attach conduit mount directlyto deck, using an included flashing and hardware or mounted Drawing to a rail or L-Foot using T-bolt. Accomodates both 1"and 3/4" conduit. EQUIPMENT: RACKING SYSTEM, BILL OF MATERIALS Sheet S-7