HomeMy WebLinkAboutPermit File BLD-2020-0760 3518 W2nd Street (3)CITY OF ANACORTES r 5/8' TYPE "X' GYP. BOARD — ON ALL SURFACES OF USABLE SPACE UNDER STAIRS CONCRETE SLAB 3/4' PLYWOOD OR OSB SUBFLOOR DOUBLE JOIST OR BEAM PER PLAN FIRE BLOCKING JOIST PER PLAN PLYWOOD HANGERBOARD FASTENED TO CARRIAGES I TO HEADER (3) 2 X 12 STRINGERS 5/5' TYPE "X' GYP. BOARD ON ALL SURFACES OF USABLE SPACE UNDER STAIRS STAIRS AT LANDING SCALE: 3/4" = 1'-0" SEE STAIR NOTES ON PAGE A4 FOR STAIR AND HANDRAIL NOTES (3) 2 X 12 STRINGERS LINE OF CANTILEVERED FLOOR ABOVE m i m A AS N i n 2X THRUST BLOCK m i m � m a 16 —5 1 /2" 29 —6 1 /2" 2"-6 ol 3"-3"" 2"-6 1 /2"" ol 3'-5 1 /2' 2"-6 5"-11 1 /2" lo ro' —4 1 /2" 8"-2 3/4" 8"-2 3/4" 11 15"-0' 14"-6 1 /2 m 3356 GSMT 335fp PIC 3356 GSMT 3056 GSMT 2956 CS T 295P PIG 2956 CSMT 3068 MR011 3" X 5 FEB 42" TALL PONY WALL \` SH ER 01, N NEW EX. NO10, w a N FAr o " s REC ROOM 00111 m wN L le" CEILING HT. THROUGHOUT ' 0 BATH 2 s 8'6"-0"" X SEDROOM 201 PARTIAL FURRING ° 3 -6"" OPTION AT CRIPPLE 0 WALL PARTIAL FURRING LINEN m OPTION AT CRIPPLE10 WALL UP 18 R GUARDRAIL 3068 2068 `v ME 2 X 4 FURRING (TYP.) I"" GAP (TYP.) D/C Q5"-11 1/2"" v � 2"-11 1/2"" � 0 SDO s 26I68 UNDER STAIIP STO�L�GE1 .� I (UNEXCAVATED) �I e o CRAWL SPACE ACCESS MIN. 24" WIDE X 36" TALL ACCESS DOOR (GARAGE ABOVE) 1 LOWER FLOOR PLAN SCALE: 1/4" = 1'-0" 844 S.F. LIVING SPACE PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT#: BLD-2020-0760 ADDRESS: 3518 VV 2nd APPROVED BY:_ SUBJECT TO FIELD INSPECTION. APPROVED PLyfS SHALL NOT BE ALTERED WITHOUT AUTHORIZA ON. Full building plans originally submitted under BLD-2017-0648. SEE ENGINEERING 52 FOR SHEAR WALL SPECIFICATIONS Ojd design ENERGY CODE NOTES • CONTRACTOR TO ADD ADDITIONAL FRAMING OR BLOCKING AS REQUIRED TO MEET CURRENT ENERGY CODE REQUIREMENTS. • AIR LEAKAGE. SOLE PLATE IS TO BE CAULKED OR GLUED TO FLOOR. RIM JOIST BETWEEN STORIES TO BE CAULKED/SEALED. ALL HOLES IN BUILDING ENVELOPE ARE TO BE CAULKED/SEALED INCLUDING BUT NOT LIMITED TO ELECTRICAL, PLUMBING ; HVAC PENETRATIONS. OUTLETS, SWITCH BOXES AND RECESSED FIXTURES ON EXTERIOR WALLS OR CEILINGS ARE TO BE CAULKED/SEALED WITH APPROVED SEALANT, OR HAVE FOAM GASKETS INSTALLED. ALL RECESSED LIGHTS ARE TO BE IC RATED, AIR TIGHT SEALED TO SURROUNDING GWB. ROUGH OPENING AROUND ALL WINDOWS f DOORS TO BE SEALED/CAULKED. • ALL CEILING EXHAUST FAN DUCTING TO BE INSULATED AS PER CODE, TO HAVE AS FEW BENDS AS POSSIBLE, AND TO TERMINATE AT THE EXTERIOR OF THE BUILDING. • INSULATION TO FILL ALL EXTERIOR WALL CAVITIES. DO NOT COMPRESS. CUT TO FIT AROUND WIRES, PIPES OUTLET BOXES. • ALL HVAC DUCTS INSTALLED OUTSIDE THE HEATED HABITABLE SPACE TO HAVE SEALED JOINTS, CORNERS BOOTS, AND INSULATED IN ACCORDANCE WITH WSEC 2015 EDITION SPECIFICATIONS ("WSEC 2015"). • A ONE PERM OR LESS VAPOR RETARDER (IE: KRAFT PAPER, PvA PAINT, ETC.) IS TO BE INSTALLED ON THE WARM SIDE OF ALL INSULATION. • ALL RECESSED LIGHT FIXTURES IN THE THERMAL ENVELOPE TO BE CERTIFIED UNDER ASTM E-283 AND SO LABELED, OR SEALED AROUND THE EXTERIOR IN AN APPROVED MANNER TO BE AIR TIGHT. • ALL WATER PIPES IN UNHEATED SPACES TO BE INSULATED IN ACCORDANCE WITH WSEC 2015. • EXTERIOR DOORS TO BE ADJUSTED SO WEATHER-STRIPPING, THRESHOLD, ; DOOR SWEEP ARE WORKING PROPERLY ; SEAL WELL. • BLOWN -IN ATTIC INSULATION TO BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURERS RECOMMENDATIONS FOR DENSITY ; COVERAGE. PROVIDE VENT BAFFLES AS REQUIRED INSULATE WEATHER-STRIP ATTIC ACCESS DOOR. • PROVIDE MAKEUP AIR WITH FRESH AIR DUCTED DIRECTLY INTO THE RETURN AIR PLENUM OF THE FURNACE SYSTEM. INSULATE THE DUCT IN ACCORDANCE TO WSEC 2015. PROVIDE DAMPER TO REGULATE INCOMING FRESH AIR. • ALL GAS COMBUSTION APPLIANCES, EXCEPT STOVES CLOTHES DRYERS, TO HAVE COMBUSTION AIR DUCTED DIRECTLY TO THEM. • ALL COMBUSTION EXHAUSTS TO BE SEPARATED BY A MIN. 3" VERT. ; 10" HORIZ. WHOLE -HOUSE VENTILATION ONE OF THE FOLLOWING METHODS WILL BE USED TO MEET THE REQUIREMENTS OF THE INTERNATIONAL MECHANICAL CODE (IMG) CHAPTER OF THE 2015 IRC: (A). A SINGLE WHOLE —HOUSE EXHAUST FAN, WHICH CAN PERFORM DOUBLE DUTY AS A ROOM SPOT FAN, IS REQUIRED. FAN MUST BE CONTROLLED BY TIMER SET TO OPERATE MIN. OF 8 HOURS PER DAY. THE CFM CAPACITY OF FAN MUST BE 0.25 W.G. AND HAVE MAX. BONE (NOISE) RATING OF 1.5. MIN. SIZE OF FAN MUST BE 105 CFM. (B). FRESH AIR WILL BE CIRCULATED BY THE CENTRAL FORCED AIR FURNACE SYSTEM. FURNACE MUST HAVE FRESH AIR INTAKE DUCT AND BLOWER MUST BE ACTIVATED BY TIMER TO CIRCULATE DAILY. INSULATION VALUES WALLS ABOVE GRADE R-21 BELOW GRADE R-21 CEILING FLAT R-49 VAULTED R-35 FLOOR CRAWL SPACE* R-30 SLAB ON GRADE R-10 • R-30 INTENDED FOR USE WITH 9 1/2' I —JOISTS. IF 11 1/8" I —JOISTS USED THEN R-35 INSULATION TO BE INSTALLED. JIM DUNLAP (360) 982-0535 JIM@JDDESIGNDRAFTING.COM w U z w 0 w r J Q w LU J c� Z Ai 0 tr O WuU z O L w LL- Z o_ z ~ N U �z W O 0 3:O Z CC)_ U - o Q W Z N EL LU lL U U W O � J w o Q O W U �z< I Fn Q CL Z a 0 0 J LL Z WO_ H U x U N W O 0 W a IL J DRAWN BY JAD SCALE 1/4" = 1'-0" UNO JD JOB# 1137NC17-DEMM DATE 11/21/2017 REVISIONS 12/3V2017 CEILING HEIGHT & STEPS, ADDED DECK STAIRS AT FLOOR SCALE: 3/4" = 1'-0" A5 SHEET 5 OF 14