HomeMy WebLinkAboutPermit File BLD-2020-0760 3518 W2nd Street (3)CITY OF ANACORTES
r
5/8' TYPE "X' GYP. BOARD —
ON ALL SURFACES OF USABLE
SPACE UNDER STAIRS
CONCRETE SLAB
3/4' PLYWOOD OR
OSB SUBFLOOR
DOUBLE JOIST OR
BEAM PER PLAN
FIRE BLOCKING
JOIST PER PLAN
PLYWOOD HANGERBOARD
FASTENED TO CARRIAGES
I TO HEADER
(3) 2 X 12 STRINGERS
5/5' TYPE "X' GYP. BOARD ON
ALL SURFACES OF USABLE
SPACE UNDER STAIRS
STAIRS AT LANDING
SCALE: 3/4" = 1'-0"
SEE STAIR NOTES ON
PAGE A4 FOR STAIR AND
HANDRAIL NOTES
(3) 2 X 12 STRINGERS
LINE OF CANTILEVERED
FLOOR ABOVE
m
i
m
A
AS N
i
n
2X THRUST BLOCK
m
i
m
� m
a
16 —5 1 /2"
29 —6 1 /2"
2"-6
ol
3"-3"" 2"-6 1 /2""
ol
3'-5 1 /2' 2"-6
5"-11 1 /2"
lo
ro' —4 1 /2"
8"-2 3/4" 8"-2 3/4"
11
15"-0'
14"-6 1 /2
m
3356 GSMT 335fp
PIC 3356 GSMT
3056 GSMT
2956 CS
T 295P PIG 2956 CSMT
3068
MR011
3" X 5 FEB
42" TALL PONY WALL
\`
SH ER
01,
N
NEW
EX.
NO10,
w
a
N
FAr
o
"
s
REC ROOM
00111
m
wN
L
le" CEILING HT. THROUGHOUT
'
0
BATH 2
s
8'6"-0""
X
SEDROOM
201
PARTIAL FURRING
°
3 -6"" OPTION AT CRIPPLE
0
WALL
PARTIAL FURRING
LINEN
m
OPTION AT CRIPPLE10
WALL
UP 18 R GUARDRAIL
3068
2068
`v
ME
2 X 4 FURRING (TYP.)
I"" GAP (TYP.)
D/C Q5"-11 1/2""
v �
2"-11 1/2""
�
0
SDO s
26I68
UNDER STAIIP
STO�L�GE1
.�
I
(UNEXCAVATED)
�I
e
o
CRAWL SPACE ACCESS
MIN. 24" WIDE X 36" TALL
ACCESS DOOR
(GARAGE ABOVE)
1
LOWER FLOOR PLAN
SCALE: 1/4" = 1'-0"
844 S.F. LIVING SPACE
PLANNING AND BUILDING DEPT:
APPROVED PLANS
REVIEWED FOR CODE COMPLIANCE
PERMIT#: BLD-2020-0760
ADDRESS: 3518 VV 2nd
APPROVED BY:_
SUBJECT TO FIELD INSPECTION. APPROVED PLyfS SHALL NOT
BE ALTERED WITHOUT AUTHORIZA ON.
Full building plans originally
submitted under BLD-2017-0648.
SEE ENGINEERING 52 FOR SHEAR WALL
SPECIFICATIONS
Ojd design
ENERGY CODE NOTES
• CONTRACTOR TO ADD ADDITIONAL FRAMING OR
BLOCKING AS REQUIRED TO MEET CURRENT ENERGY
CODE REQUIREMENTS.
• AIR LEAKAGE. SOLE PLATE IS TO BE CAULKED OR
GLUED TO FLOOR. RIM JOIST BETWEEN STORIES TO BE
CAULKED/SEALED. ALL HOLES IN BUILDING ENVELOPE
ARE TO BE CAULKED/SEALED INCLUDING BUT NOT
LIMITED TO ELECTRICAL, PLUMBING ; HVAC
PENETRATIONS. OUTLETS, SWITCH BOXES AND
RECESSED FIXTURES ON EXTERIOR WALLS OR CEILINGS
ARE TO BE CAULKED/SEALED WITH APPROVED
SEALANT, OR HAVE FOAM GASKETS INSTALLED. ALL
RECESSED LIGHTS ARE TO BE IC RATED, AIR TIGHT
SEALED TO SURROUNDING GWB. ROUGH OPENING
AROUND ALL WINDOWS f DOORS TO BE
SEALED/CAULKED.
• ALL CEILING EXHAUST FAN DUCTING TO BE INSULATED
AS PER CODE, TO HAVE AS FEW BENDS AS POSSIBLE,
AND TO TERMINATE AT THE EXTERIOR OF THE BUILDING.
• INSULATION TO FILL ALL EXTERIOR WALL CAVITIES. DO
NOT COMPRESS. CUT TO FIT AROUND WIRES, PIPES
OUTLET BOXES.
• ALL HVAC DUCTS INSTALLED OUTSIDE THE HEATED
HABITABLE SPACE TO HAVE SEALED JOINTS, CORNERS
BOOTS, AND INSULATED IN ACCORDANCE WITH WSEC
2015 EDITION SPECIFICATIONS ("WSEC 2015").
• A ONE PERM OR LESS VAPOR RETARDER (IE: KRAFT
PAPER, PvA PAINT, ETC.) IS TO BE INSTALLED ON THE
WARM SIDE OF ALL INSULATION.
• ALL RECESSED LIGHT FIXTURES IN THE THERMAL
ENVELOPE TO BE CERTIFIED UNDER ASTM E-283 AND
SO LABELED, OR SEALED AROUND THE EXTERIOR IN AN
APPROVED MANNER TO BE AIR TIGHT.
• ALL WATER PIPES IN UNHEATED SPACES TO BE
INSULATED IN ACCORDANCE WITH WSEC 2015.
• EXTERIOR DOORS TO BE ADJUSTED SO
WEATHER-STRIPPING, THRESHOLD, ; DOOR SWEEP ARE
WORKING PROPERLY ; SEAL WELL.
• BLOWN -IN ATTIC INSULATION TO BE INSTALLED IN STRICT
CONFORMANCE WITH MANUFACTURERS
RECOMMENDATIONS FOR DENSITY ; COVERAGE.
PROVIDE VENT BAFFLES AS REQUIRED INSULATE
WEATHER-STRIP ATTIC ACCESS DOOR.
• PROVIDE MAKEUP AIR WITH FRESH AIR DUCTED
DIRECTLY INTO THE RETURN AIR PLENUM OF THE
FURNACE SYSTEM. INSULATE THE DUCT IN ACCORDANCE
TO WSEC 2015. PROVIDE DAMPER TO REGULATE
INCOMING FRESH AIR.
• ALL GAS COMBUSTION APPLIANCES, EXCEPT STOVES
CLOTHES DRYERS, TO HAVE COMBUSTION AIR DUCTED
DIRECTLY TO THEM.
• ALL COMBUSTION EXHAUSTS TO BE SEPARATED BY A
MIN. 3" VERT. ; 10" HORIZ.
WHOLE -HOUSE
VENTILATION
ONE OF THE FOLLOWING METHODS WILL BE USED TO MEET
THE REQUIREMENTS OF THE INTERNATIONAL MECHANICAL
CODE (IMG) CHAPTER OF THE 2015 IRC:
(A). A SINGLE WHOLE —HOUSE EXHAUST FAN, WHICH CAN
PERFORM DOUBLE DUTY AS A ROOM SPOT FAN, IS
REQUIRED. FAN MUST BE CONTROLLED BY TIMER SET TO
OPERATE MIN. OF 8 HOURS PER DAY. THE CFM
CAPACITY OF FAN MUST BE 0.25 W.G. AND HAVE MAX.
BONE (NOISE) RATING OF 1.5. MIN. SIZE OF FAN MUST BE
105 CFM.
(B). FRESH AIR WILL BE CIRCULATED BY THE CENTRAL
FORCED AIR FURNACE SYSTEM. FURNACE MUST HAVE
FRESH AIR INTAKE DUCT AND BLOWER MUST BE
ACTIVATED BY TIMER TO CIRCULATE DAILY.
INSULATION VALUES
WALLS
ABOVE GRADE
R-21
BELOW GRADE
R-21
CEILING
FLAT
R-49
VAULTED
R-35
FLOOR
CRAWL SPACE*
R-30
SLAB ON GRADE
R-10
• R-30 INTENDED FOR USE WITH 9 1/2'
I —JOISTS. IF 11 1/8" I —JOISTS USED THEN
R-35 INSULATION TO BE INSTALLED.
JIM DUNLAP
(360) 982-0535
JIM@JDDESIGNDRAFTING.COM
w
U
z
w
0
w
r
J
Q
w
LU
J
c�
Z
Ai
0
tr
O
WuU
z
O
L
w
LL-
Z
o_
z
~
N
U
�z
W O
0
3:O
Z
CC)_
U
-
o
Q
W
Z
N EL
LU
lL
U
U
W
O � J
w
o
Q O W
U
�z<
I
Fn Q CL
Z
a
0
0
J
LL
Z WO_
H
U
x
U
N
W O
0
W
a
IL J
DRAWN BY JAD
SCALE 1/4" = 1'-0" UNO
JD JOB# 1137NC17-DEMM
DATE 11/21/2017
REVISIONS
12/3V2017 CEILING HEIGHT
& STEPS, ADDED DECK
STAIRS AT FLOOR
SCALE: 3/4" = 1'-0"
A5
SHEET 5 OF 14