Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0736 3204 R Avenue (2)GEOTEST 1.888.251.5276 Bellingham I Arlington I Oak Harbor www.g eotest-i nc-corn FIELD DENSITY/MOISTURE REPORT Nuclear Gauge * ASTM D6938 PROJECT: 3204 R Ave JOB #: 21-0223 ADDRESS: 3204 R Ave, Anacortes, WA REPORT #: FDO01 PERMIT #: DATE: 1/20/2021 CLIENT: Landed Gentry Development PAGE #: 1 of 1 CONTRACTOR: Landed Gentry Development INSPECTOR: Larry Nichols Compaction Of: Building Pad Subgrade Backfill Field Data: Test # Location Depth/ Elev (ft) DT/ BS (in) Wet Density (pcf) Field Moisture (%) Dry Density (pcf) Lab # Compaction % Pass/ Fail - eEl1= 1 Center of Lot -2 -12 146.3 6.5 137.3 1 99 95 P 2 Southeast Corner -2 -12 143.0 7.2 133.4 1 96 95 P 3 Northeast Corner -2 -12 142.5 6.5 133.8 1 96 95 P 4 Northwest Corner -2 -12 141.3 6.9 132.2 1 95 95 P Lab Sample # Soil Type Source Max. Dry Density (pcf) Optimum Moisture (%) Retained On #4 (%) Test Method 1-NA PGS with Gravel Miles S&G Boulder Hill Pit (IS-93) 138.9 6.4 41 ASTM D1557/D4718 2- 0.0 None 3- 0.0 None Gauge Make/Model/Serial#: InstroTek/3500/3505 M/D Standard Count: 405/2926 Calibration Date: 2/22/2020 Comments: GeoTest was on -site, as requested, to perform in -place density testing at the above locations. All tests attained the required compaction results on this date. The contractor was notified of the results prior to leaving the site. Proctor was provided by the client. COPIES: art@landedgentry.com Reviewed by This report shall not be reproduced except in full, without the written approval of GeoTest Services, Inc. The above test results relate only to the sample (or location) tested.