Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0439 2602 17th Street (10)Window Schedule 101.B 102.E 00 101.A 102.A I co FINISHED FLOOR Window lRoorn ISize I Type No. IStyle II 101.A M.Bed 24"X56" Casement 2 vinyl clad 102.A M.Bed 30"x56" Casement 2 vinyl clad 101.B M.Bed 24"x24" Picture/Awning option 4 vinyl clad 102.B M.Bed 72"x24" Picture 1 viny clad Door Schedule Dr No. lRoom ISize IType lRating IDoor Mat. 101.1 Garage 3'x6'8" 20 min rated solid n/a wood/mtl 102.1 Garage 9'X7'0" Raised panel n/a mtl. 103.1 Garage 3'X6'8" French n/a wood/mtl 201.1 M.Bed 6'x6'8" Slider n/a wood/mtl 201.2 lCloset 2'6"X6'8" 1pocket Door n/a 1wood 201.3 IlLaundry 5'X6'8" Bi-Pass n/a 1wood 201.4 IMI. Bath 2'6"X6'8" lint. Swing n/a 1wood INTERIOR POCKET 00 I 201.2 SLIDER 00 Fim iD ED 20 MIN. 101.1 GARAGE ROLLUP 102.1 INT. CLOSET ED AREA OF WORK Typ. Deck f I Assembly DEX-TREX OR SIMILAR DECKING MATERIAL OVER P.T. 2X10 FRAME ATTACHED j TO P.T. 2X10 LEDGER I POST/BEAM PER STRUCT LAYOUT I ...... I FINISH GRADE Shed Roof Construction 30 YEAR COMPOSITION ROOFING OVER 15# ROOFING PAPER OVER 7/16 EXTERIOR ROOF SHEATHING OVER ENGINEERED ROOF TRUSS OR 2X12 ROOF RAFTERS W/ R-49 BATT INSULATION PROVIDE SOFFIT VENT MIN. 1" AIRSPACE -- __________--____ __ EXISTING MUM WALL HIT. ITO RESIDENCE NOT EXCEED 12' PER PRECRIPTIVE DESIGN CRITERIA N T-i POLYU O WATER OOF MEMBR qE cv OVER PLYWD. r (I DECKING - R SID �C_E] O I N 1SY2 A 10g�A LAP WATERPROOF MEMBRANE MIN. 12" UP VERT.WALL A 1 PARTIAL PORTAL FRAME A2.3 THIS CORNER ONLY El EXISTING RESIDENCE FINISH GRADE AREA OF WORK I WSP Typ. Exterior Wall Construction PAINTED HARDIE BOARD LAP SIDING OVER TYVEK BUILDING WRAP OVER 7/16" EXTERIOR SHEATHING OVER 2X6 FRAME WALLS AT 16" O.C. W/ R-21 BATT INSULATION Typ. Exterior Wall Construction PAINTED HARDIE BOARD LAP SIDING OVER TYVEK BUILDING WRAP OVER 7/16" EXTERIOR SHEATHING OVER 2X6 FRAME WALLS AT 16" O.C. W/ R-21 BATT INSULATION Typ. Floor Construction FIN. FLOOR MATERIAL OVER 3/4" T&G PLYWD. OVER 11-7/8"TJI 360 /W PRE I MANUFATURED KNOCKOUTS FOR MECH/ELECT. W/ R38 BATT INSULATION ■ PROVIDE SOFFIT VENT I MIN. 1" AIRSPACE WSP "I O I I I I I I I- MAIN FLOOR LEVEL wal I I = I I .\ I I 00 Typ. Conc. Stem Construction; �. 6" THICK P.I.P. CONCRETE STEMWALL WSP I 101.B <1102�.B 101.A), C 101 FINISH GRADE GAR. FLOOR LEVEL I FENTIREWER AND UPPER BE SHEATHED STRUCTURALSP) NORTH ELEVATION 1/4" = 1'-0" Shed Roof Construction 30 YEAR COMPOSITION ROOFING OVER 15# ROOFING PAPER OVER 7/16 EXTERIOR ROOF SHEATHING OVER ENGINEERED ROOF TRUSS OR 2X12 ROOF RAFTERS W/ R-49 BATT INSULATION Typ. Exterior Wall Construction PAINTED HARDIE BOARD LAP SIDING OVER TYVEK BUILDING WRAP OVER 7/16" EXTERIOR SHEATHING OVER 2X6 FRAME WALLS AT 16" O.C. W/ R-21 IBATT INSULATION I *.% Ai__� I Typ. Deck Assembly 1 0 DEX-TREX OR SIMILAR DECKING MATERIAL OVER I;� P.T. 2X10 FRAME ATTACHED o TO P.T. 2X10 LEDGER '� POST/BEAM PER STRUCT ILAYOUT _ MAIN FLOOR LEVEL 1 I ' -rw I I I I I I I I I I I , I I I I I I = WSP I I � co I I � I I I I I I ` I I � GAR. FLOOR LEVELjk FENTIREWER AND UPPER Typ• Conc. Retaining BE SHEATHEDWall Construction STRUCTURALSP) 8" THICK P.I.P. CONCRETE STEMWALL SEE STRUCT. EAST ELEVATION 1/4" = 1'-0" EXTERIOR ELEVATION GENERAL NOTES 1. SLOPE GRADE A MINIMUM OF 2% AWAY FROM THE BUILDING FOR A MINIMUM DISTANCE OF 5'-0" 2. PAINT ALL EXPOSED VENTS ON ROOF TO MATCH ROOF COLOR. 3. PAINT ALL EXPOSED VENTS ON SIDING TO MATCH SIDING COLOR. 4. MAINTAIN 8" CLEARANCE BETWEEN NATURAL GRADE AND EXPOSED WOOD 5. ALL DECK RAILINGS SHALL BE 42" TALL MINIMUM. ALL OPENINGS SHALL BE CONSTRUCTED TO PREVENT A 4" SPHERE FROM PROJECTING THROUGH THE OPENING. 6. WHERE INDICATED, CORNER BOARDS SHALL BE 2x. IN CASES WHERE WINDOWS OR DOORS ARE LESS THAN 14" FROM A CORNER, INCREASE CORNER BOARD SIZE SO THE JAMB TRIM IS THE CORNER BOARD VERIFY ALL CORNERS. 7. REFER TO MPE SHEETS FOR EXTERIOR LIGHTING. ALL EXTERIOR LIGHTING SHALL HAVE A CONCEALED LIGHT SOURCE. 8. ALL EXTERIOR SIDING MATERIALS SHOWN SHALL COMPLY WITH CBC CHAPTER 7A & CRC CHAPTER R327 FOR IGNITIION RESISTANCE. 9. ALL EXTERIOR GLAZING SHALL BE INSULATED AND TEMPERED. 10. ALL EXTERIOR DOORS SHALL BE SOLID CORE WOOD WITH STYLES AND RAILS NOT LESS THAN 1-3/4" THICK AND INTERIOR FIELD PANELS NO LESS THAN 1-112" THICK. 11. ALL WALL VENTS SHALL BE PROTECTED BY CORROSION RESISTANT, NON-COMBUSTIBLE WIRE MESH WITH 1/8" MAXIMUM OPENINGS. 12. CEDAR AND REDWOOD SIDING/TRIM SHALL ALL BE ATTACHED WITH COLOR COATED STAINLESS STEEL RING SHANK NAILS 13. INSTALL 4" WIDE, 30# ASPHALT SATURATED FELT STRIP BEHIND ALL BUTT TRIM JOINTS FOR FULL LENGTH OF JOINT. CENTER STRIP ON JOINT. 14. ALL EXPOSED MECHANICAL AND PLUMBING VENTING LOCATIONS TO BE APPROVED BY OWNER PRIOR TO INSTALLATION AND PAINTED A COLOR THAT COMPLEMENTS THE SURROUNDING MATERIAL (ROOF/SIDING). 15. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, COMCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. 0 N � U . M O 0) C -0 . @) (a (a 0-O �4- (n � 01 U) +� N -C- i r 4-� NO _0 M O V) N V) U M fu N O N - Ln C Q) r a) � CN � co N Ca M N O X O M Q CN Q Document Date: June 1, 2016 Document Phase: Construction Documents date remark 07/01/16 plan revision X ELEVATIONS A301 The use of these plans and specifications is restricted to the original site for which they were prepared. Re -use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Michael Trafton. Ownership of the design, plans and specifications is solely with Michael Trafton. Shed Roof Construction 30 YEAR COMPOSITION ROOFING OVER 15# ROOFING PAPER OVER 7/16 EXTERIOR ROOF SHEATHING OVER ENGINEERED ROOF TRUSS OR 2X12 ROOF RAFTERS W/ AREA OF WORK---\ R-49 BATT INSULATION 1 Typ. Exterior Wall Construction I PAINTED HARDIE BOARD LAP SIDING OVER TYVEK BUILDING WRAP OVER 7/16" EXTERIOR SHEATHING OVER 2X6 FRAME WALLS AT 16" O.C. W/ R-21 BATT INSULATION Typ. Deck ' - - - Assembly Typ. Floor I 00 DEX-TREX OR SIMILAR Yp LOCATION OF DECKING MATERIAL OVER C HEAT PUMP .� P.T. 2X10 FRAME ATTACHED `COMPRESSOR , FIN. FLOOR MATERIAL OVER 3/4" T&G O TO P.T. 2X10 LEDGER PLYWD. OVER 11-7/8"TJI 360 /W PRE EXISTING - POST/BEAM PER STRUCT MANUFATURED KNOCKOUTS FOR I LAYOUT MECH/ELECT. W/ R38 BATT INSULATION RESIDENCE IMAIN FLOOR LEVEL ITyp. Conc. Stemwall Construction 6" THICK P.I.P. CONCRETE STEMWALL � IDOOR AND WINDOW TRIM AT EXTERIOR SIDING: ° STAINED 1X2 HEAD TRIM WITH GALV. METAL FLASHING ° STAINED 1X2 JAMB TRIM C0 FINISH GRADE o STAINED 1X2 SLOPED STOOL STAINED 1X2 APRON _ GAR. FLOOR LEVEL — .. — .. — .. — .. — .. — .. — .. — .. — .. — .. — .. — .. 00 l K7*\NS0UTH ELEVATION 0 q 7 1 /4" = V-0" Shed Roof Construction AREA OF WORK 30 YEAR COMPOSITION ROOFING OVER 15# ROOFING PAPER OVER 7/16 EXTERIOR ROOF SHEATHING OVER ENGINEERED ROOF TRUSS OR 2X12 ROOF RAFTEF,S W/ R- 49 BATT INSULATION Typ. Exterior Wall Construction PAINTED HARDIE BOARD LAP SIDING OVER TYVEK BUILDING WRAP OVER 7/16" EXTERIOR SHEATHING OVER 2X 3 FRAME WALLS AT 16" O.C. W/ R-21 BATT INSULATION Typ. Floor Construction FIN. FLOOR MATERIAL OVER 3/4" T&G PLYWD. OVER 11-7/8"TJI 360 S.S.0 /W PRE MANUFATURED KNOCKOUTS FOR MECH/ELECT. W/ R38 BATT INSULATION I Typ. Conc. Retaining Wall Construction I 6" THICK P.I.P. CONCRETE STEMWALL SEE STRUCT. LINE OF FOUNDATION BELOW I FINISH GRADE — I Typ. Conc. Stemwall Construction 8" THICK P.I.P. CONCRETE STEMWALL SEE STRUCT. ---- - - - - -- V01 101. ao1.� — _ EXISTING c T .'. WSP LOCATIO OF - — — T \ HEAT PU OP RESIDENCE ALL EXTERIOR SIDING MATERIAL COMPRE 3SOR _ TO MATCH EXISTING AND TO BE - - PAINTED TO MATCH EXISTING WSP —_ -- - - WSP 00 I I I = C I I I I I I I I —..—..—..—..—..—..—..—..—..—.L.—..—..—. I I I /DOOR -----------------------------------------------------------------ND WINDOW TRIM AT EXTERIOR SIDING: AINTED 1X2 HEAD TRIM WITH GALV. METAL FLASHING FENTIREWER AND UPPERPAINTED 1X2 JAMB TRIM BE SHEATHED°PAINTED 1X2 SLOPED STOOL STRUCTURALSP) WEST ELEVATION 1 /4" = V-0" GAR. FLOOR LEVEL EXTERIOR ELEVATION GENERAL NOTES 1. SLOPE GRADE A MINIMUM OF 2% AWAY FROM THE BUILDING FOR A MINIMUM DISTANCE OF 5-0" 2. PAINT ALL EXPOSED VENTS ON ROOF TO MATCH ROOF COLOR. 3. PAINT ALL EXPOSED VENTS ON SIDING TO MATCH SIDING COLOR. 4. MAINTAIN 8" CLEARANCE BETWEEN NATURAL GRADE AND EXPOSED WOOD 5. ALL DECK RAILINGS SHALL BE 42" TALL MINIMUM. ALL OPENINGS SHALL BE CONSTRUCTED TO PREVENT A 4" SPHERE FROM PROJECTING THROUGH THE OPENING. 6. WHERE INDICATED, CORNER BOARDS SHALL BE 2x. IN CASES WHERE WINDOWS OR DOORS ARE LESS THAN 14" FROM A CORNER, INCREASE CORNER BOARD SIZE SO THE JAMB TRIM IS THE CORNER BOARD - VERIFY ALL CORNERS. 7. REFER TO MPE SHEETS FOR EXTERIOR LIGHTING. ALL EXTERIOR LIGHTING SHALL HAVE A CONCEALED LIGHT SOURCE. 8. ALL EXTERIOR SIDING MATERIALS SHOWN SHALL COMPLY WITH CBC CHAPTER 7A & CRC CHAPTER R327 FOR IGNITIION RESISTANCE. 9. ALL EXTERIOR GLAZING SHALL BE INSULATED AND TEMPERED. 10. ALL EXTERIOR DOORS SHALL BE SOLID CORE WOOD WITH STYLES AND RAILS NOT LESS THAN 1-3/4" THICK AND INTERIOR FIELD PANELS NO LESS THAN 1-1/2" THICK. 11. ALL WALL VENTS SHALL BE PROTECTED BY CORROSION RESISTANT, NON-COMBUSTIBLE WIRE MESH WITH 1/8" MAXIMUM OPENINGS. 12. CEDAR AND REDWOOD SIDING/TRIM SHALL ALL BE ATTACHED WITH COLOR COATED STAINLESS STEEL RING SHANK NAILS 13. INSTALL 4" WIDE, 30# ASPHALT SATURATED FELT STRIP BEHIND ALL BUTT TRIM JOINTS FOR FULL LENGTH OF JOINT. CENTER STRIP ON JOINT. 14. ALL EXPOSED MECHANICAL AND PLUMBING VENTING LOCATIONS TO BE APPROVED BY OWNER PRIOR TO INSTALLATION AND PAINTED A COLOR THAT COMPLEMENTS THE SURROUNDING MATERIAL (ROOF/SIDING). 15. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, COMCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. E O ,-� ) O -E 00 O� O C . CaJ U N O L fU C r�' a--+ ct� W 3: O M C J NJ- 01 +J N ro � +,, � 0 70 M to L.. O . N U) U M ro N O a)_ E Ln t C ru Z 4-, k M �+ CN Y co U W (M 0 a) CZ 4_0 c� CN O X C:)(0 � Q C Q Document Date: June 1, 2016 Document Phase: Construction Documents date remark 07/01/16 plan revision X ELEVATIONS A302 The use of these plans and specifications is restricted to the original site for which they were prepared. Re -use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Michael Trafton. Ownership of the design, plans and specifications is solely with Michael Trafton.