HomeMy WebLinkAboutPermit File BLD-2022-0686 3952 Rock Ridge Parkway City of Anacortes Invoice/Permit#: BLD-2022-0686
G 904 6th Street
Applied date: 08/29/2022
�?""' �►' P.O.Box 547 Issue date: 08/29/2022
Anacortes, WA 98221-0547
Expire date: 02/25/2024
(360) 293-1901
0 Ix
Job Address: 3952 ROCK RIDGE PKWY Permit Type: PV Solar Permit
ANACORTES WA 98221 Project:
APN:
Remarks: Install solar array on rooftop.
Owner: BRIAN&HELEN WORTHINGTON Contractor: ECOTECH SOLAR
Address: 2520 BERENTSON CT Address: 1331 MEADOR AVE
SUITE 103
ANACORTES WA 98221-4517 BELLINGHAM WA 98229
Phone: (206)612-8813 Phone: (360) 318-7646
License#:
General Information: Fees:
Building Valuation 2500 Building Permit Fee 83.25
Plan Review Fee 54.11
State Building Code Fee Resi 6.50
Total Calculated: 143.86
Deposits/Receipts: 0.00
Total Due: 143.86
The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of
the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or
granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or
federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be
valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order, proclamation, guidance advice or decision of
the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,
inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or
decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is
suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examine this application and know the same to
be true and correct.
SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSU
o
c< =
Ln
Lo
1 ICD <
cl
. - - -
� cE nor
W �ort� �► 'a
CL
c
~ v� �a
PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT
Mailing Address: P.O. Box 547, Anacortes, WA 98221
c�oR Office Location: 904 61h Street, Anacortes WA 98821
Phone: (360) 293-1901
RESIDENTIAL BUILDING PERMIT APPLICATION
THIS APPLICATION PACKET IS USED FOR THE FOLLOWING PROJECT TYPES:
Single-Family Residences (SFR), Duplexes, Additions & Remodels, Accessory Structures (i.e. garages,
carports), Accessory Dwelling Units, Manufactured Homes, Residential Decks & Retaining Walls, and
Docks& Pilings.
FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION
PROPERTY INFORMATION
PROJECT ADDRESS(STREET,SUITE#) ASSESSOR PARCEL NUMBER
3952 Rock Ridge Pkwy, P134325
SUBDIVISION/LOT# ZONING LOT AREA(SIZE) 9967
lot 14 R2 SQ. FT.
TYPE OF PROJECT
NEW ADDITION REPAIR REMODEL CHANGE OF USE
SFR Lj Duplex ❑Deck/Porch
Accessory Dwelling Unit: ❑Detached ❑Attached ❑Retaining Wall
❑ Manufactured Home ❑Accessory Structure
❑ Shoreline Structure(dock, pilings,floats etc.) * ❑X Other: Rooftop PV system
*If application is for a shoreline structure, please complete the Shoreline Structure Checklist.
IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? I YES ✓ NO
f YES, provide the permit/application number:
PROJECT SUMMARY: PROJECT VALUATION
Installation of Solar PV array (Cost of Materials & Labor)
$2500
PROPERTY OWNER INFORMATION
NAME PHONE
Brian Worthington
ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS
3952 Rock Ridge Pkwy,
CONTRACTOR INFORMATION
NAME* PHONE
Ecotech Solar 360-318-7646
CONTRACTOR'S BUSINESS LICENSES STATE LICENSE# EXPIRATION
*All Contractors&Subcontractors must have a valid City ECOTEES951 RG 12-28-23
of Anacortes business license prior to doing work in the UBI# EXPIRATION
City.
602-44-974 10-31-22
ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS
1331 Meador Ave, bellingham WA 9822 andys@ecotechsolar.com
Page 1 of 17
Res.Building Permit Application Submittal Checklist
Updated April 20,2021
CONTACT PERSON -Select one person the city will contact for anything related to this project:
EC APPLICANT ❑PROPERTY OWNER ❑CONTRACTOR ❑OTHER(LIST BELOW)
NAME PHONE
Andy Schene 360-318-7646
ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS
see above andys@ecotechsolar.com
LENDER INFORMATION
RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lender
involved with your project, write "no lenders"on the Name Line below.
NAME PHONE
ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS
ACKNOWLEDGEMENTS & SIGNATURE
Read and initial each of the following statements prior to signing this application:
AS1 understand that when a building permit application is taken in over the counter it does not mean
the application has been deemed technically complete and sufficient for staff review.
ASI understand that if 1 submit incomplete, inaccurate, and/or erroneous information it will take the
City longer to process my permits.
ASI understand and acknowledge that I could be responsible for providing as-built drawings(on paper
or electronically)as part of the project's certificate of occupancy process.
AS1 understand and acknowledge that Special Inspections could be required as part of my project, and
if needed 1 will be required to pay for the cost of these inspections.
AS 1 understand and acknowledge that financial securities could be required as part of the work I am
completing and I agree to provide the items needed for the City to calculate these securities and to
provide the securities themselves.
AS I understand that if permits are reviewed concurrently such as design review, site plan, traffic
concurrency, etc., any required revisions to one permit may affect the entire plan set and could add
costs and time to the project.
I hereby declare that 1 am either the owner of the property listed on this application or the owner of
this property has authorized me to be their representative to act for them. I also declare under penalty
of perjury under the laws of the State of Washington that all of the statements and answers contained
herein, and the information submitted with this application form is in all respects, true, correct, and
complete to the best of knowledge and belief.
8-25-22
SIGNATURE DATE
Andy Schene
PRINTED NAME
Res.Building Permit Application Submittal Checklist
Updated December 2021
Page 2 of 17
�1 iiI I
I LI 1 I p
1 I LI Y I 4
I I I 1 I
I i I sl I Y '
I I I I I I I I
I I I I I I Y
I L
1 1 I i I I I 1 I
1 1 I I I I 1 I
I I ,
1 I Y
I r I I 1 I I
I
4
1 I Y I
I� 7
!
1 I �
I I
I � '
I � o
I
I
I
I I
I
I II �
o °
I
CD
I
I L1
I
I
I
a
I
I
I
I �
I ,
I
1 - -- - t;
/ lF
I
!
4 +
r —
C 'h r
4 +
I
� r
k
m
� I I
� I I
� I 1
I I I I I I
1 I I I 1 I
1 I I I I I
1 I I I 1 I
1 I I I 1 I
1 I I I 1 I
h a I k I I I I
y I I I
,TY o City of Anacortes Photovoltaic System Permit
Submittal Requirements
Permit Required: A building permit is required for the installation or replacement of
solar/photovoltaic (PV) systems, including roof top arrays, ground-mounted arrays and PV
water heaters. An electrical permit is required from the State Department of Labor &
Industries.
Single family residence rooftop installations meeting the criteria in the attached checklist are
eligible to obtain a building permit over-the-counter at the permit center in City Hall.
CODES: International Residential Code (Current Edition)
International Building Code (Current Edition)
International Fire Code (Current Edition)
National Electrical Code (Current Edition)
FEES: Building Permits for installations are based on the material cost of the support system
and labor for the installation.
SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS):
1) Permit Application Form A.
2) Site plan showing location of house and array/equipment on lot, with setback
dimensions to property lines.
3) Roof plan showing the array.
4) Manufacturer specifications or the PV panels and mounting hardware. Include the
weight of the equipment.
5) For rooftop systems not conforming to all of the criteria in the attached checklist,
provide a roof framing plan and either:
a) Structural calculations by a WA State Licensed Engineer or other competent person
showing the adequacy of the existing roof structure to support the additional load,
or
b) Documentation showing that the roof structure was substantially overbuilt
compared to prescriptive code requirements.
6) For ground mounted systems provide structural calculations by a WA state licensed
engineer or other competent person showing how the structure meets wind design
requirements for the structure and footings. Note that ground mounted equipment
greater than 36 inches in height must adhere to minimum required property line
setbacks of the applicable zoning district.
NOTE: The purpose of this handout is to assist the public in complying with detailed permit
submittal requirements. It is NOT a complete list of permit or code requirements and
should NOT be used as a substitute for applicable laws and regulations. It is the
responsibility of the owner/design professional to review the submittal for completeness
and applicability to other codes. Only complete applications will be accepted by the City for
review.
To Be Completed By the Applicant
Project Address: 3952 Rock Ridge Pkwy,Anacortes, WA 98221
Project Applicant:Andy Schene
Applicant Email:andys@ecotechsolar.com Phone No.:360-318-7646
Site Owner Name:Brian Worthington
PV System Description: 10.08 kW roof mounted solar electric system
Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No
1. PV System is designed and proposed for a detached single-family house,duplex or ❑ ❑
townhome. X
2. PV System is designed for rooftop of house in general compliance with applicable ❑ ❑
codes. X
3. Mounting system is engineered and designed for PV. )C1 ❑
4. Rooftop is made from light weight material such as shingles. )C1 ❑
5. PV system will be permitted and pre-approved by Labor& Industries Electrical ❑ ❑
division. X
6. To address uplift, panel are mounted no higher than 18"above the surface of the EX ❑
roofing to which they are affixed. Except for flat roofs, no portion of the system
may exceed the highest point of the roof.
7. Total deal load of panels,supports, mountings, race ways,and all other ❑
appurtenances weight no more than one of the following. IF Yes, indicate which:
❑ No more than three and one half(3.5 pounds per square foot(PSF)
❑ Frameless panels on at least 3/12 pitch roof weighing no more than four and
one-half(4.5) PSF
❑ Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0)
PSF
8. Supports for solar panels are installed to spread the dead load across as many Ex ❑
roof-framing members as needed to ensure that no point loads in excess of fifty
(50) pounds are created.
9. Attachment to the roof is specified by the mounting system manufacturer. )C1 ❑
10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to ❑ ❑
pitched roofs). X
Comments:
v By Checking this box, I certify that all of the information provided on this form is correct.
If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter
building permit. To apply please bring in this completed form to our permit center at City Hall for an
over-the-counter permit.
To be Completed By Staff
Project is eligible for over-the-counter permit? ❑Yes ❑ No
3952 Rockridge Parkway(#1019546) AQk IRONRIDGE
pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545
Project Details
Name 3952 Rockridge Parkway Date 08/26/2022
Location 3952 Rockridge Parkway,Anacortes,WA 98221 Total modules 28
Module Hanwha Q.Cells: Q.PEAK DUO 13LK-G10+ 365 (32mm) Total watts 10,220
Dimensions Dimensions: 67.6" x 41.14"x 1.26" (1717.Omm x 1045.Omm x 32.Omm) Attachments 56
ASCE 7-10 Rails per row 2
System Weight Load Assumptions
Total system weight 1,437.1 Ibs Wind exposure B
Weight/attachment 25.7 Ibs Wind speed 110 mph
Racking weight 208.8 Ibs Ground snow load 15 psf
Distributed weight 2.6 psf Attachment spacing portrait 4.0'
Roof Information
Roof Material Family Comp Shingle Roof material Comp Shingle
Building height 30 ft Roof attachment FlashVue
Roof slope 9 o Attachment hardware Square
Risk category II
Span Details XR100 - Portrait Reaction Forces XR1OO - Portrait
Zone Down Uplift Lateral
Zone Max span Max cantilever (Ibs) (Ibs) (Ibs)
1 8' 5" 3' 1 233 90 35
2 8' 5" 3' 2 233 189 35
3 8' 1" 3' 3 233 301 35
Last updated by Andy Schene on 08/26/22 11:04 PM Page 1 of 6
3952 Rockridge Parkway(#1019546) AQk IRONRIDGE
pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545
Roof Section 1
Details Weights
Panels: 28 Provided rail: 224' [16 x 168"] Total weight: 1,437.1 Ibs
Rail orientation: East-West Attachments: 56 Weight/attachment: 25.7 Ibs
Panel orientation: Portrait Splices: 8 Total Area: 551.0 sq ft
Entry type: Graphical Clamps: 64 Distributed weight: 2.6 psf
Diagram
co
Omn-
N
■
I I
24' 4"
Segments
Identifier Columns Row Rail Cantilever Cantilever Rail Attachments Splices Clamps
length length Violations
A 7 24' 4" 24' 4" 2" None 56' [4 x 1681 14 2 16
Row segment totals (x 4) -> 224' [16 x 56 8 64
168"]
Contour Plan -Trim Cut List
Identifier Scrap from Length Scraps Created Discard
Last updated by Andy Schene on 08/26/22 11:04 PM Page 2 of 6
3952 Rockridge Parkway(#1019546) IRONRIDGE
pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545
Side View (portrait)
9°
PV MODULE
RAI L
FLASHVUE
ROOF MEMBRANE
BUILDING STRUCTURE
Front View (portrait)
4.0'
ATTACHMENT SPAN
�PV MODULE
RAIL
FLASHVUE
ROOF MEMBRANE
BUILDING STRUCTURE
77!7RAF-FER
Last updated by Andy Schene on 08/26/22 11:04 PM Page 3 of 6
3952 Rockridge Parkway(#1019546) AQk IRONRIDGE
pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545
Splice Details
TOP-FACING SLOT
XR100 RAIL
INTERNAL SPLICE r BONDING SPRING
XR100 INTERNAL SPLICE
SIDE-FACING SLOT Splice Connection
4-
XR100
Clamp Detail
PV MODULE UNIVERSAL RAIL STOPPER
FRAME FASTENING 1„ 1„ SLEEVE
OBJECT PV MODULE UNIVERSAL
------- - - ----- UNIVERSAL
FRAME FASTENING
-------- FASTENING PV MODULE - OBJECT
---_--- OBJECT FRAME UNIVERSAL
----
FASTENING
--------- --------- OBJECT
RAIL
RAIL
STOPPER PV MODULE
SLEEVE FRAME
Mid Clamp,Plan Mid Clamp,Front End Clamp,Plan End Clamp,Front
FlashVue Detail
B„
jo
2.1" 2.74"
12"
2.07"
< I
Plan View Side View Perspective View Front View
Last updated by Andy Schene on 08/26/22 11:04 PM Page 4 of 6
3952 Rockridge Parkway(#1019546) AQk IRONRIDGE
pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545
Grounding Diagram
- - - - - - - - - - - - - - - - - - - - - - - - - - 0
T- - - �,- - - - - - - - - - - -
T
0
- - - - - - - - - - - -
- - - - - -
- - - - - - 0
- - - - - - - - - - - - - -
T T
0 - - - - - - - - + - - - - - - - - - - - - - - - - - 0
OUFO Clamp • Grounding Lug
Fault Current Ground Path Min 10 AWG Copper Wire
m Bonded Splice (Rail Connection)
*Grounding Lugs and Wire are not required in systems using Enphase microinverters.
Last updated by Andy Schene on 08/26/22 11:04 PM Page 5 of 6
3952 Rockridge Parkway(#1019546) ZMk IRON RIDGE
pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545
Bill of Materials
Part Spares Total Qty
Rails& Splices
XR-100-168B 0 16
XR100,Rail 168"(14 Feet)Black
XR100-BOSS-01-M1 0 8
Bonded Splice,XR100
Clamps&Grounding
UFO-CL-01-B1
0 64
Universal Module Clamp,Black
UFO-STP-32MM-B1 0 16
Stopper Sleeve,32MM,Black
XR-LUG-03-Al 0 4
Grounding Lug,Low Profile
Attachments
FV-01-B1 0 56
FlashVue,Black
BHW-SQ-02-Al 0 56
Square-Bolt Bonding Hardware
Last updated by Andy Schene on 08/26/22 11:04 PM Page 6 of 6