Loading...
HomeMy WebLinkAboutPermit File BLD-2022-0650 3949 Rock Ridge Parkway 1 C} City of Anacortes Invoice/Permit#: BLD-2022-0650 904 6th Street Applied date: 08/16/2022 P.O.Box 547 Issue date: 08/24/2022 _� t►�: Anacortes, WA 98221-0547 Expire date: 02/20/2024 11 (360) 293-1901 Job Address: 3949 ROCK RIDGE PKWY Permit Type: Fire Sprinkler Permit ANACORTES WA 98221 Project: APN: Remarks: Install a NFPA 13D system in a new SFR,whose permit number is BLD-2021-0931. Owner: JOSHUA&JENNIFER WEISBERG PRICE Contractor: X-FIRE SECURITY Address: 11733 174TH PL NE Address: 1511 KENTUCKY ST REDMOND WA 98052 BELLINGHAM WA 98229-4718 Phone: (425)301-2223 Phone: (360)715-8088 License#: XFIRE**961 PN General Information: Fees: Building Valuation 18622 Building Permit Fee 307.25 Plan Review Fee 199.71 State Building Code Fee Comm 25.00 Total Calculated: 531.96 Deposits/Receipts: 0.00 Total Due: 531.96 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY �(•/�IV' Y PLANNING,, COMMUNITY., & ECONOMIC DEVELOPMENT DEPARTMENT FIRE SPRINKLER PERMIT APPLICATION 77 1'l�lailing A ddress: P. 0. Box 5=# ?, Ancicortes, WA 98221 '�� � Office Local 'on 904 61 Street, 4nacortes WA 98821 .. .. Phone., (360) 293-1901 P L EASE kEF E R TO THE FIRE .SP RINKL E R P F. R.YTf T C HE CKL 1S T FO R .S UB+1111 T TA L R E I[R E-VE N TS El MQDIFY EXISTING SYSTEM INSTALL NEW SYSTEM El UNDERGROUND FIRE LINE PROJECT ADDRESS (Street, Suite #}: PARCEL(S)A: PI -34-318 3949 Rack Ridge Pkwy Anacortes, INA 98221 PROJECT VALUATION: $ 18,621 .75 APPLICANT: x_Fire Security Phone: 360-715-8088 Address (Street, City, State, dip) : Email Address. projects a[7x-fire . us 1511 Kentucky Street, Bellingham WA 58229 PROPERTY OWNER: Weisberg - Price ; Phone - Address (Street, City., State, Zip) : 3949 Rock Ridge Pkwy Email Address: AnaGortes, VITA 9$221 CONTACT PERSON : pan Eardley � �an� : 360-715-8088 Address (Street, Cite, State, Zip): Email Address: dan a[7x-fire . us 15 1 1 Ke ntucky Street, Be l l i ng ha m WA 9 8229 � CONTRACTOR: " x-Fire Security Phone . 360-7 15-808$ Address (Street.', Citv, State. Zip) .- Email Address 1511 Kentucky Street, Bellingham WA 98229 projects(gx-fire. us State Sprinkler Certificate & License # : Exp. Date : *All Contractor's & subcuntrcrctors must have a valid City of xFlRE`*981 PN 12131122 Anarnrtes business ficenseprior to doing work in the City. the �"rf}� 's Finance Department at (360) 299-19GS. Busi ���ss License #: 60� � 67180 Fxp. Date - Contact 1213 1i22 C OMMERCIAL ❑ RESIDENTIAL OCCUPANCY CLASS: SPRINKLER STANDARD : HAZARD CLASS: Is this work, associated with another project? Yes EJ Nn /", If yes, specify: PROPOSED WORK: NFPA 13D Multipurpose Fire Sprinkler System . Installation in a New Residential Home . I declare under penalty of perjury that the information I have provided an this forrri/application is true, correct, aFid complete, and th at I am the prop e rty n«'tle r or d u ly authariled agent o f the property owner to s u bmi t a p erm i t application to the i of Anacort � A� a � (specifv): 69L®r-e !�1. C O�j-ner ❑ e tqr\.,4,o0- Print dame_ � signature: Date: � �� �`�a�- Bulletin 006 Rev.K February 2017 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Product Features • cULus Listed as Residential Sprinklers � - • Push-On cover plate installation • Low water flow requirements s Product Description Model RFC30 Model RFC43 Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. Model RFC30, RFC43, and RFC49 sprinklers have a 1650F (74°C) temperature rated fusible-link operating element. Model RFC49 Model RFC58 Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 1650F(74°C)temperature rating are ordinary temperature classification and should be used with a 135°F(57°C)temperature rated cover plate. Sprinklers with a 212°F(100°C)temperature rating are inter- mediate temperature classification and should be used with a 1650F(74°C)temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43,and RFC49 sprinklers allow 1/2" (13 mm)of cover plate adjustment. Model RFC58 sprinklers allow 3/4" (19 mm)of cover plate adjustment. Model RFC cover plates are available in a variety of finishes Solid Perforated as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or Model RFC Cover Plate perforated cover plates. Nominal K-Factor Max.Coverage Area Sprinkler Sprinkler Model gpm/psi12(1/min/bar12) ft x ft(m x m) Identification Number(SIN) RFC30 3.0(43.2) 14 x 14(4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20(6.1 x 6.1) RA0612 RFC49 4.9(70.6) 20 x 20(6.1 x 6.1) RA0616 RFC58 5.8(84) 20 x 20(6.1 x 6.1) RA0613 www.reliablesprinkler.com Model •ential Sprinkler SIN RA0612 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NPT or ISO 7-1 R11/2 Nominal K-Factor:4.3(62 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Rating Material Specifications 165°F(74°C)sprinkler Thermal Sensor:Nickel Alloy Solder Link 135°F(57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC Pins:Stainless Steel [� Deflector:Bronze Alloy Listings and Approvals Bottom View n.t Cup:Steel cULus Listed Model RFC43 Sprinkler Components and Dimensions 2-5/16"(58 mm) Threads Dia. Body = - Cup �` Tower 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link Nominal face of fitting to ceiling Deflector(retracted) ....... 3/16"(5 mm) Pin(extended) Deflector(extended) 1 tf Model RFC Cover Plate 3-5/16"(84 mm)Dia. V,Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0.63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev. K ��' Page 3 of 7 February 2017 www.reliablesprinkler.com Bulletin 135 April 2021 ® Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Features Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2(non- Available in pendent and horizontal sidewall orientations cULus Listed Residential Sprinklers recessed)and Model W4(recessed,concealed)are required. • • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element.A variety of K-Factors as well as recessed and conical concealed options are available as c detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626.They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1 Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R,or NFPA 13D.The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy,where permitted by the design density shall be a minimum of 0.1 gpm/sf(4.1 mm/ NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA min), but in no case shall the flow and pressure be less than the 13D applications,the design flow and pressure shall not be minimum flow and pressure specified in the Listed Design Criteria less than the minimum flow and pressure specified in the Listed tables in this bulletin. Model F1 Res Series sprinklers are listed for Design Criteria tables in this Bulletin. For NFPA 13 applications, use in wet systems only. Residential Sprinkler Summary NERM, Sprinkler K-Factor Sprinkler Identification Orientation gpm/psi112 Thread Size Installation Options Max.Coverage Area ft Model Number(SIN) (Ipm/bar'/z) NPT or ISO7-1 x ft(m x m) F1 Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16(4.9 x 4.9) F1 Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed 14 x 14(4.3 x 4.3) F1 Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20(6.1 x 6.1) F1 Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed 20 x 20(6.1 x 6.1) F1 Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20 x 20(6.1 x 6.1) F1 Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res44 SWC R3531 Horizontal Sidewall 4.4(63) 112 Conical Concealed 16 x 20(4.9 x 6.1) F1 Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) Note: Please note SIN difference between F1 Res58 HSW(R3533)and F1 Res58 HSWX(RA3533). www.reliablesprinkler.com Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler SIN R3531 Technical Specifications Finishes Style:Conical Concealed Sidewall (See Table N) Threads:1/2"NPT or ISO 7-1 R1/2 Sensitivity Nominal K-Factor:4.4(63 metric) Fast-response Max.Working Pressure: 175 psi(12 bar) Temperature Ratings 155°F(68°C) 1 Material Specifications 175°F(79°C)(') Thermal Sensor:3 mm glass-bulb Cover Plates SWC J Sprinkler Frame:Brass Alloy SWC Conical Concealed Plate(�) Button:Copper Alloy SWC-2(Slotted)Conical Concealed Plate(') Sealing Assembly:Nickel Alloy with PTFE Sprinkler Wrenches Load Screw:Bronze Alloy Model W4 Deflector:Bronze Alloy SWC-2 Note: (t)Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2)135°F SWC Conical Concealed Plate for 155OF(68°C)sprinklers (3)135°F SWC-2(Slotted)Conical Concealed Plate for 175°F(79°C)sprinklers Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1"(25mm) 1"(25mm) +/-1/4"(6mm) +/-1/4"(6mm) Face of fitting to finished wall 2-5/8" 2:DIA. ___- Top of Deflector Down 3 5/16" (67mm 5 - -c_ ti - from Ceiling to be Either ) ( -�--- - 4"to 6"(100mm to (84mm DIA. 150mm)or 6"to 12" DIA. 5/16" (150mm to 300mm) (8mm) Based on Hydraulic Calculations 1 5/8" H-(41mm) Dimensions SWC&SWC-2 Concealed Cover Plate Installation Model F1 Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst'1 Ordinary Temperature Rating Intermediate Temperature Rating Maximum Coverage Area(2) 1550F(68-C) 175°F(79°C) Deflector to Ceiling ft.x ft.(m x m) Flow Pressure Flow Pressure Distance gpm(1/min) psi(bar) gpm(1/min) psi(bar) 12 x 12(3.7 x 3.7) 13(49) 8.7(0.60) 14(53) 10.2(0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2(0.7) 14(53) 10.2(0.7) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) -- -- 4 to 6 inches 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) -- __ (100 to 150 mm) 16 x 18(5.5 x 5.5) 19(72) 18.7(1.31) -- -- 16 x 20(4.9 x 6.1) 23(87) 27.4(1.89) -- -- 12 x 12(3.7 x 3.7) 14(53) 10.2(0.7) -- -- 14x14(4.3x4.3) 15(57) 11.7(0.81) -- -- 15 x 15(4.6 x 4.6) 17(64) 15.0(1.03) -- __ 6 to 12 inches (150 to 300 mm) 16 x 16(4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16 x 18(4.9 x 5.5) 20(76) 20.7(1.43) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 Reliable Page 11 of 15 April 2021 www.reliablesprinkler.com Bulletin 157 December 2021 Riallmabld Model F3QR56 Dry K5.6 (80 metric) CTI Quick-Response, o Standard Spray Sprinklers 3 Features o 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheon • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon • Horizontal Sidewall with Model HB extended escutch- Pendent Pendent/HB eon • Horizontal Sidewall with Model FP recessed escutch- (See Fig. 1) (See Fig. 2) eon (FM Standard Response) • Horizontal Sidewall with Model F1 recessed escutch- eon (FM Standard Response) • Upright 2. Available with 1" NPT, ISO7-1R1, 3/4" NPT, or IS07- 1 R3/4 inlet fitting. 3. 3/4" NPT inlet fittings permit replacement of older 3/4" inlet dry sprinklers without changing to a larger sprinkler fitting. Recessed FP Pendent Concealed 4. Sprinklers, escutcheons, and cover plates are available (See Fig. 3) (See Fig.4) in a wide variety of standard and special application fin- ishes. 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT)finish sprinklers are cULus Listed as Corro- sion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pressure rating for Dry Pendent and select HSW configurations. \ FM Approved for 175 psi (12 bar). Product Description Recessed F1 Pendent Horizontal Sidewall Model F3QR56 Dry sprinklers are quick-response, standard (See Fig. 5) (See Fig.6) coverage sprinklers with a nominal K-Factor of 5.6(80 metric). Available in Dry Pendent, Dry Horizontal Sidewall, and Dry Up- right configurations, Model F3QR56 Dry sprinklers all use a 3 mm glass bulb operating element. See the Temperature Rat- ings table in this Bulletin for available temperature ratings. Mod- el F3QR56 Dry sprinklers are intended for installation on wet- pipe, dry-pipe, or preaction sprinkler systems in accordance i with NFPA 13, FM Property Loss Prevention Data Sheets, and Horizontal Sidewall/HB Recessed FP other applicable installation standards. (See Fig.7) Horizontal Sidewall Model F3QR56 Dry Pendent and Sidewall sprinklers are avail- (See Fig.8) able with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F3QR56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Available sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, ' Model FP escutcheon,and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model Recessed F1 F3QR56 Dry sprinklers;the use of any other recessed escutch- Horizontal Sidewall eon or cover plate with Model F3QR56 Dry sprinklers will void (See Fig.9) Upright all guarantees,warranties, listings and approvals. (See Fig. 10) Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Inlet fittings are available with 1"NPT,ISO 7-1 R1,3/4"NPT,or See the Available Configurations, Listings, and Approvals IS07-1 R3/4 threads.Sprinklers with 3/4"NPT and IS07-1 R3/4 table in this Bulletin for further information on Model F3QR56 inlet fittings are intended primarily for replacement of existing Dry sprinklers. 3/4"or IS07-1 R3/4 inlet dry sprinklers, but may also be used in new installations. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Length Listings and Inlet Identification Model Cover Plate Approvals0) Threads Number (See Figs. 1-9) (SIN) Standard 2"to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon F1 Recessed cULus, NYC 3/4" NPT or Escutcheon 3-1/2"to 36" IS07-1 R3/4 FP Recessed (90 to 900 mm) Escutcheon F3QR56 Dry CCP Cover Plate R5714 Pendent Standard 2"to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT F1 Recessed cULus, FM, NYC or Escutcheon 3-1/2"to 48"Escutcheon R1 FP Recessed (90 to 1200 mm) Escutcheon CCP Cover Plate Standard 2"to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus(2), NYC(2) 3/4" NPT or F1 Recessed 3-1/2"to 48" IS07-1 R3/4 Escutcheon (90 to 1200 mm) FP Recessed F3QR56 Dry Escutcheon R5734 Horizontal Sidewall Standard 2"to 48" Escutcheon (50 to 1200 mm) c , FM(3)3>, Ny>C(2) HB Extended 3-1/2"to 48" Escutcheon (90 to 1200 mm) 1" NPT or F1 Recessed IS07-1 R1 Escutcheon 3-1/2"to 48" cULus(2), FP Recessed (90 to 1200 mm) FM(3)(4), NYC(2) Escutcheon F3QR56 Dry N/A 5"to 48" cULus(2) 1" NPT or R5724 Upright (127 to 1200 mm) IS07-1 R1 (')For available temperature ratings and finishes see the Temperature Ratings and Finishes tables,respectively,in this Bulletin. (2)cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (1)FM Approved for Light Hazard only. (4)Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. 2. Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi'/2 (80 L/min/bar'12) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry cULus,NYC See note below 250 psi(17.2 bar) Pendent FM See note below 175 psi(12 bar) F3QR56 Dry cULus,NYC 4"to 6" 250 psi(17.2 bar) Horizontal Sidewall 4"to 12" 175 psi(12 bar) FM See note below 175 psi(12 bar) F3QR56 Dry Upright cULus See note below 175 psi(12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Sprinkler Cover Plate Maximum Ceiling Listings and Classification Glass Bulb Color Temperature Rating Temperature Rating Temperature ApprovalsM Orange 135°F(57°C) Ordinary 135°F(57°C) 100°F(38°C) cULus,FM,NYC Red 155°F(68°C) Intermediate Yellow 175°F(79°C) 165°F(74°C) 150°F(66°C) cULus,NYC Intermediate I Green I 200°F(93°C) I 165°F(74°C) 150°F(66°C) I cULus,FM,NYC High Blue 286°F(141°C) None 225°F(107°C) cULus, FM(2),NYC 165°F(74°C) 150°F(66°C) cULus,NYC (')For listed and approved sprinkler,escutcheon,and inlet configurations see the Available Configurations,Listings,and Approvals table in this Bulletin. (2)High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finish Notes 1. Finishes vary with type of trim selected. See table provided with each sprinkler detail for finish combinations. 2. Paint or any other coating applied over the factory finish will void all approvals and warranties. 3. Other finishes and colors may be available on special order.Consult your Reliable sales representative for details. 4. For Standard, Model HB, and Model F1 trims, both components of escutcheon are finished. 5. For Model FP and CCP trims,only the trim ring and cover plate are finished.The threaded sprinkler cup is unfinished. 3. Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) "A"Dim. 2"to 48"(51 mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 2"to 36" 51 mm to 914mm in 1/4" 6mm increments for 3/4"connections I IIIIII I I IIIIIII II �� IIIIII__I IIIIIII ___A �_—_ Milli_—i—_i--Tnnil � 11 I� �I�I�I I I I�I�r1 I ----I41J---A L-- 41----- , i iI L J System Fitting Inlet Fitting 2-1/8" "A" Dimension [54mm] Dia. Hole in Ceiling 1-1/4" Sprinkler Can [32 mm] Escutcheon Adjustment Escutcheon 15/32" [12mm] Ceiling Nominal Escutcheon Position 1/4" [6 mm] 1-5/8" Escutcheon Adjustment [41 mm] 1/4" [6 mm] 7� t Nominal Protrusion 3" Sprinkler Guard: Model C2 [76 mm] COMDRYDETI DIA. Fig. 1 Note:The sprinkler can protrudes%"when escutcheon is in nominal position. Escutcheon adjustment provides-'/4"(-6mm)to+1'/4" (+32mm)"A"dimen- sion adjustment range. Notes: Finish Combinations:Standard Escutcheon 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheon(2)(3) 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel unless noted. Bronze Polished Stainless 4. FM Approved as Corrosion Resistant. Bronze Laquered Brass Chrome Polished Stainless White PolyesterM White Polyester Black Polyester(') Black Polyester Custom Color Polyester(') Custom Color Polyester Electroless Nickel PTFE(4) Polished Stainless 4. HEHHU Unlimited Polymer Solutions FIREPEX° RESIDENTIAL FIRE SPRINKLER SYSTEM Design and Installation Guide � R t a _ rT f• 2. DESIGN & APPLICATIONS 2.1 Applications 2.2 Types of Fire Sprinkler Systems The FIREPEX residential fire sprinkler system serves the requirements The NFPA 13D standard categorizes all fire sprinkler systems within for fire sprinkler systems as defined by National Fire Protection two general types:wet pipe systems and dry pipe systems. Association(NFPA)Standard 13D Installation of Sprinkler Systems in Wet pipe systems are filled with water and installed in areas not One-and Two-Family Dwellings and Manufactured Homes and the subject to freezing. International Residential Code Section(IRC)P2904. Dry pipe systems are not filled with water,and can be located in unheated areas subject to freezing. The purpose of NFPA 13D and IRC P2904 is to provide a sprinkler system that aids in the detection and control of residential fires,thus The FIREPEX system is for wet pipe systems only. offering improved protection against injury and loss of life.A sprinkler Within the wet pipe systems,NFPA 13D defines the layout of systems system that is designed and installed in accordance with this standard under the following types,for which the FIREPEX system can be is expected to prevent flashover(total involvement of the fire)in the installed: room of fire origin,where sprinklered,and to improve the chance for Multipurpose Sprinkler System occupants to escape or be evacuated. Passive Purge Sprinkler System Stand-alone Sprinkler System RAUPEX white UV shield pipe and EVERLOC+fittings are approved for use in residential fire sprinkler systems as defined by NFPA 13D and IRC P2904 for a variety of residential applications including single- 2.2.1 Multipurpose Sprinkler Systems or two-family homes,town homes,modular homes and manufactured Multipurpose systems are defined in NFPA 13D and IRC P2904 as a housing. piping system intended to serve both fire sprinklers and domestic plumbing needs.A multipurpose system integrates the piping connected to a water supply with sprinklers that automatically discharge water over a fire area.All piping in a multipurpose system supplying sprinklers must be listed or conform to the piping specifica- tions in NFPA 13D or IRC P2904. To Domestic Het Water Fire Sprinkler -- TIP Relief Valve Domestic Domestic T Water Healer Fixture Flxlure Fire Sprinkler Domestic Flxlure Fig.2.1:FIREPEX installation Domestic Het Water Water Meter Domestic Coltl Water -------Find— See,-Line Fire Protection City Water Main Fig.2.2:Multipurpose system 4 3. SYSTEM OVERVIEW 3.1 Application The FIREPEX residential fire sprinkler system includes RAUPEX white UV shield(PEXa)pipe, EVERLOC+polymer and lead-free brass fittings, PEXa compression sleeves and EVERLOC+compression- sleeve tools. The EVERLOC+compression-sleeve fitting system is a cold- expansion PEXa fitting system available in polymer and lead-free(LF) brass,assembled with a specially designed PEXa compression sleeve. The fittings are designed specifically for use with RAUPEX pipe and must only be assembled with EVERLOC+compression-sleeve tools. Fig.3.3:EVERLOC+compression-sleeve tools 3.2 Standards and Certifications _ RAUPEX white UV shield pipes are certified for use in residential fire 7-- sprinkler�r sprinkler systems as defined by NFPA 13D or IRC P2904. RAUPEX red and blue UV shield are not certified for fire sprinkler • .- systems. The FIREPEX system is third-party certified by NSF International (www.nsf.org)to the following standards: UL 1821 Standard for Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service Fig.3.1:RAUPEX white uvshield crosslinked polyethylene(PEXa)pipe ASTM F877 Standard Specification for Crosslinked Polyethylene (PEX)Hot-and Cold-Water Distribution Systems CSA 13137.5 Crosslinked Polyethylene(PEX)Tubing Systems for Pressure Applications NSF/ANSI 14 Plastic Piping System Components and Related Materials NSF/ANSI 61 Drinking Water System Components and Related Materials NSF/ANSI 372 Drinking Water System Components—Lead Content (complies with the lead-free requirements of the U.S.Safe Drinking Water Act) 3.3 Warranty RAUPEX UV shield pipe and EVERLOC+compression-sleeve fittings and sleeves are backed by a 25-year limited warranty. EVERLOC+ Fig 3.2:EVERLOC+compression-sleeve fittings and PEXa compression sleeves compression-sleeve tools are backed by a 2-year limited warranty. REHAU offers this warranty when the installation is carried out in accordance with the requirements outlined in the REHAU PEXa Warranty 855.018,which is available as a separate document at www.na.rehau.com/warranties. 4. RAUPEX PEXa PIPE 4.1 Pipe Properties Specification English SI Standardn Crosslinked polyethylene is polyethylene(PE)which has undergone a Tensile 4194-4355 psi 26-30 N/mm2 change in molecular structure whereby the polymer chains are Strength @68°F a20°C linked,crosslinked X,with each other to form a three- @176'90o psi 18-20 N/mmz chemically ( ) 176°F @80°C dimensional network.The result is a flexible thermoset polymer with per ASTM D638 per ASTM D638 improved mechanical,thermal and chemical properties. IzoD Impact No Break No Break Resistance There are three methods of manufacturing PEX: Roughness e=0.00028 in. e=0.007 mm The peroxide method(PEXa),ASTM requires a minimum of 70% Temperature -40 to 200°F -40 to 93°C crosslinking Working Range The silane method(PEXb),ASTM requires a minimum of 65% Maximum 150 psig CSA 210°F 1035 kPa @ 99°C ASTM F876 Short-term (48 hr) (48 hr) crosslinking Exposure The radiation method(PEXc),ASTM requires a minimum of 659/o uv Resistance See TB218 ASTM 2657 crosslinking RAUPEX pipe is manufactured using the peroxide method(PEXa), 4.2 Pipe Dimensions and Weights which yields the highest,most consistent level of crosslinking.PEXa RAUPEX white UV shield pipe for residential fire sprinkler systems is technology enhances flexibility and thermal memory,providing ease of available in nominal sizes ranging from 3/4 to 2 in.,and is in accor- handling and kink repair compared to PEXb and PEXc. dance to the dimensional standards defined in ASTM F876 and CSA 6137.5.RAUPEX is copper tube size(CTS)outside diameter(OD), PEXa has distinct advantages over other polymer and metal pipes: which means that the actual OD of the pipe is 1/8 in(3.18 mm)larger Resists pitting and stress corrosion than the nominal size. Resists scaling and deposit build-up when used with both hard and softened water Wall thickness is defined by the standard dimensional ratio(SDR). Minimizes noise that is transmitted through pipes RAUPEX UV shield pipe is SDR9,which equates to the outside Resists notching and abrasion damage diameter being approximately nine times the wall thickness.Since PEX pipe has a thicker wall than copper tube,the inside diameter(ID) RAUPEX is manufactured by REHAU in a facility whose quality is slightly smaller. However,since PEX pipe is not susceptible to the management system is ISO 9001 certified.In addition,RAUPEX erosion and corrosion issues of copper tube,systems can be designed production is independently monitored annually by NSF International, at higher velocities which allow for comparable sizing of a system. CSA Group and Underwriters Laboratories Inc.(UL). Table 4.2:RAUPEX White UV Shield Pipe Dimensions and Weights Table 4.1:RAUPEX Properties ,• - Weight Specification English si d. Minimum 58 Ib/ft3 926 kg/m3 ASTM 1876 3/4 in 0.875(22.22) 0.097(2.47) 0.10(0.15) Density 1 in 1.125(28.58) 0.125(3.18) 0.17(0.26) Minimum 70% 70% ASTM F876 1 1/4 in 1.375(34.92) 0.153(3.88) 0.25(0.37) Degree of 1 112 in 1.625(41.28) 0.181(4.59) 0.35(0.52) Crosslinking Max Thermal 2.84 Btu in/(ft2°F.hr) 0.41 W/(m K) DIN 16892 2 in 2.125(53.98) 0.236(6.00) 0.60(0.90) Conductivity Coefficient of 9.33 x 10-4 in/ft°F 0.14 mm/(m C) Mean @ Linear @68°F @20°C 20-70°C per DIN 4.3 Pipe Markings Expansion 1.33 x F 3 in/ft°F 0.2 mm/(m°C) 16892 RAUPEX pipe markings are repeated ever 3 ft 0 9 m list all @212°F c�1oo°c p•p g p Y ( )� • certifications and approvals,and include an incremental footage Modulus of 87,000-130,500 psi 600-900 N/mmz Minimum @ marking to assist with installation. Elasticity @ 68°F @20°C 20°C per DIN 43,500-58,000 psi 300-400 N/mm2 16892 @176°F @80°C 8 5. EVERLOC+ COMPRESSION-SLEEVE FITTINGS 5.1 Fitting Scope 5.1.2 Fitting and Sleeve Markings The EVERLOC+compression-sleeve system is a cold-expansion PEXa All polymer fittings include the following marks for identification fitting system that is available in polymer and lead-free(LF)brass and is assembled with a specially designed PEXa compression sleeve.The R E H A U 1 fitting is designed specifically for use with RAUPEX pipe and must ORS only be assembled with the EVERLOC+compression-sleeve tools. EVERLOC+fittings for residential fire sprinkler applications are available in 3/4 to 2 in.sizes and are listed for use with RAUPEX white UV shield pipe(3/4 to 2 in.)manufactured in accordance with ASTM F876. For a detailed description of the REHAU system components,refer to the REHAU Building Solutions Product Catalog(855.312). 5.1.1 Fitting Features Fig.5.2.Fitting size marking (e.g.,3/4') EVERLOC+polymer and lead-free(LF)brass fittings have the following features: 1. Four sealing edges 2. Pipe stop w 3. Fitting collar 4. Tool jaw body i Fig.5.3:Batch code(e.g.,production date) All LF brass fittings are marked"REHAU" All sleeves include the following marks for identification REHRH 4HRU 314' Sleeve size(e.g.,3/4") Batch code for production date © Fig.5.4:Sleeve markings Fig.5,1:EVERLOC+fitting features 11 5.1.3 Polymer Fittings EVERLOC+polymer fittings are available in couplings,tees,elbows, multi-port tees and plugs.All polymer fittings are produced from a polyphenylsulfone(PPSU)material.See also REHAU Technical Bulletin 1B265 EVERLOC+Polymer Fitting Material-PPSU. 5.1.4 Lead Free(LF)Brass Fittings EVERLOC+LF brass fittings are available as couplings,tees,elbows, plugs and transition fittings to NPT thread and copper solder connections.All metal fittings are produced from ECO BRASS°(UNS Fig.5.6:EVERLOC+PEXa compression sleeves 69300 or CW 724R).See also REHAU Technical Bulletin TB264 EVERLOC+Lead-free Brass Fitting Material. 5.1.6 Certifications The EVERLOC+compression-sleeve fitting system is certified to the following standards: UL 1821 Standard for Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service ASTM F877,Standard Specification for Crosslinked Polyethylene Am !.: (PEX)Hot-and Cold-Water Distribution Systems NSF/ANSI 14, Plastic Piping System Components and Related r ;r_� Materials NSF/ANSI 61,Drinking Water System Components—Health Effects NSF/ANSI 372,Drinking Water System Components—Lead Content CSA 13137.5,Crosslinked polyethylene(PEX)Tubing Systems for Pressure Applications Fig.5.5:EVERLOC+polymer and LF brass fittings 5.1.5 PEXa Compression Sleeves EVERLOC+compression sleeves are produced using a specially formulated PEXa material and are designed specifically for use with EVERLOC+fittings and RAUPEX pipe.EVERLOC+compression sleeves have the following features: Co-extruded platinum-colored PE coating Squarely cut ends that can be slid over the pipe in either direction Grooved and roughened inside surface for locking the sleeve into place once slid over the pipe and fitting 12 7. INSTALLATION CONSIDERATIONS The following sequence is recommended to install the FIREPEX fire 7.2 Mounting FIREPEX Sprinkler Fittings sprinkler system: Determine location of sprinklers based on design.Be sure to verify Determine fire sprinkler location that there are no obstructions or deviations from design.If modifica- Install sprinkler fittings tions are necessary,consult with the designer to ensure proper Route and connect pipe coverage of sprinklered area. Install plumbing fittings Install plumbing pipe The FIREPEX sprinkler fittings are available in 3/4 and 1 in.sizes. Install fire sprinklers Each fitting has a 1/2 in.NPT female adapter for mounting of the fire Perform pressure test sprinkler with integrated mounting holes for both horizontal and Perform flow test vertical installation.Fittings should be mounted using#10 x 1 1/2 in. wood screws. 7.1.Ensuring Design Meets Installation Guidelines FIREPEX sprinkler fittings are specially designed to affix the fire RAUPEX white UV shield pipe in 3/4 to 2 in.sizes is listed to supply sprinkler in place so that during activation,the reaction forces caused the FIREPEX system. by the flow of water through the sprinkler will not displace the sprinkler.FIREPEX sprinkler fittings may be mounted to a wood RAUPEX pipe in all sizes is listed for plumbing applications and can be blocking structure. connected to the sprinkler system as allowed by the local code. The following are guidelines for using RAUPEX white UV shield pipe and EVERLOC+compression-sleeve fittings in fire sprinkler systems: " Protection must be provided for RAUPEX pipe and EVERLOC+ fittings.The minimum protection must consist of either: One layer of 3/8 in.(9.5 mm)gypsum wallboard, A suspended membrane ceiling with lay-in panels or tiles having a weight of not less than 0.35 Ibs per sq ft(1.7 kg per sq m)when installed with metallic support grids, 112 in.(13 mm)plywood soffits, One layer of 1/2 in.(13 mm)plywood,or Other material having a 15 minute fire rating. During remodeling or ceiling repair, use appropriate precautions to Fig.7..1:Mounting RREPEXsprinklerfitting properly protect the pipe. Do not use RAUPEX pipe or EVERLOC+fittings for sprinkler systems in combustible concealed spaces where sprinklers are required. 7.2.1 Determining Mounting Height RAUPEX pipe and EVERLOC+fittings are intended for use in areas The following guidelines may be used to correctly position the where the maximum ambient temperature does not exceed 1207 FIREPEX sprinkler fittings.These guidelines apply to both the (49°C). If the ambient temperature is expected to exceed this FIREPEX tee and elbow fittings. When installing,blocking may be limitation,the system must be properly protected. necessary in order to position the fitting and sprinkler correctly. Piping must be installed at least 24 in.(61 cm)from air return grilles or other openings in the ceiling. A WARNING Mounting height of sprinkler must be within sprinkler manufacturer guidelines.Failure to properly position the sprinkler can cause disruption in discharge or delay in sprinkler activation,resulting in property damage and possible loss of life. 24 7.2.1.1 Flat Plate Pendent Concealed Sprinkler Mounting For a flat-plate pendent concealed sprinkler,the bottom of the FIREPEX sprinkler fitting bracket can be located using: H=S—DW+0.35(inches) (1) where: H is the distance between the bottom of the joist and the bottom of the FIREPEX sprinkler fitting bracket S is the distance from the top of the threads of the fire sprinkler to the face of the drywall(provided by the sprinkler manufacturer) DW is the thickness of the drywall. H S bw Fig.72:Flat plate pendent concealed spdnkler mounting diagram Fig.7.3.Flat plate pendent concealed sprinkler mounting example 25 1= Product REHFi U Submittal Product: RAUPEX"Non-Barrier Pipe Date: 19-August-05 Submittal#: 100RAUPEXNB Category: RAUPEX Pipes Page: 1 of: 1 C REHAU RAUPEX Non-Barrier Pipe A QB Article No. Nominal A OD'in.(mm) BID3 in.(mm) C Wall tZ in. Weight Capacity Diameter (mm) lb/ft(kg/m) Gal*/foot(1/m) 261683 3/8" 0.500 12.7 0.360 9.1 0.070 1.8 0.04 0.06 0.0050 0.0624 261026 1/2" 0.625 15.9 0.485 12.3 0.070 1.8 0.05 0.08 0.0098 0.1222 261046* 3/4" 0.875 22.2 0.681 17.3 0.097 2.5 0.10 0.16 0.0189 0.2356 261066* 1" 1.125 28.6 0.875 22.2 0.125 3.2 0.17 0.26 0.0316 0.3939 261086 1 1/4" 1.375 34.9 1.069 27.2 0.153 3.9 0.25 0.37 0.0467 0.5827 261106 1 1/2" 1.625 41.3 1.263 32.1 0.181 4.6 0.35 0.52 0.0650 0.8118 138331 1 2" 2.125 54.0 1.653 42.0 0.236 6.0 0.60 0.90 0.1114 1.3906 1-Average OD from ASTM F 876 2-Minimum Wall t from ASTM F 876 3-ID is calculated based on OD(1)and Wall t(2) *US Gallon TECHNICAL DESCRIPTION Specification English SI Standard Specification English SI Standard Minimum ASTM F 876 4194-4355 psi 26-30 N/mm2 Density 58 Ib/fN 926 kg DIN 53479 Tensile @ 68°F @ 20°C Strength 2610-2900 Degree of 7089% 7089% DINASTM1 psi 18-20 N/mm2 DIN 53455 F 876 9 Cross-Linking DIN 6892 @ 176°F @ 80°C Thermal 0.24 0.41 DIN 52612 IZOD Impact No Break No Break DIN 53453 Conductivity BTU/(hrft°F) w/(m°K) Res. Linear Exp. 9.33 x 10-4 in/ft°F @ 68°F 0.14 mm/(m°C)@ 20°C DIN 42328 Temperature -40°F to 200°F -40°C to 93°C N/A 1.33 x 10-3 in/ft°F @ 212°F 0.2 mm/(m°C)@ 100°C Working Range 87,000-130,500 psi 600-900 N/mm2 Roughness e=0.00028 in a=0.007 mm N/A Modulus of @ 68°F @ 20°C DIN 53457 Max.Short- 150 psig @ 1035 kPa @ ASTM F 876 Elasticity 43,500-58,000 psi 300-400 N/mm2 term Exposure 210°F(48 hr) 99°C(48 hr) @176°F @ 80°C UV Resistance 15 days 15 days PPI TN-33 FUNCTIONAL DESCRIPTION RAUPEX Non-Barrier pipe is manufactured using REHAU's high-pressure peroxide method for cross-linked polyethylene (Engel method, PEXa).All RAUPEX Non-Barrier pipe meets or exceeds the requirements of ASTM F 876,F 877,CSA B 137.5 and PPI TR-3,and is certified to NSF Standards 14/61. RAUPEX Non-Barrier pipe also meets the requirements of NSF P 171 and ASTM F 2023 for chlorine resistance. RAUPEX Non-Barrier pipe is produced in REHAU's ISO 9001 certified manufacturing facilities. *These pipes are certified by UL to UL 1821 and by ULC to ULC-ORD C199P for NFPA 13D fire protection applications. RAUPEX Non-Barrier pipe is rated for continuous operation of 160 psi @ 73.4°F(1105 kPa @ 23°C),130 psi @ 120°F(900 kPa @ 49°C),100 psi @ 180°F(690 kPa @ 82.2°C)and 80 psi @ 200°F(550 kPa @ 93.3°C). It is compatible with brass crimp ring fittings certified to ASTM F 1807, RAUPEX compression nut fittings, and EVERLOC compression-sleeve fittings certified to ASTM F 2080 and CSA B 137.5. Use of RAUPEX Non-Barrier pipe in heating systems requires corrosion protection and/or isolation by using a heat exchanger or non-ferrous components throughout the system. The information contained herein is believed to be reliable,but no representations,guarantees,or warranties of any kind are made as to its accuracy,suitability for particular applications or the results to be attained therefrom. Before using,the user shall determine suitability of the information for users intended use and shall assume all risk and liability in connection therewith. Installation shall comply with local codes where applicable. To the extent permitted by law,REHAU DISCLAIMS ALL WARRANTIES,EXPRESS OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. POLYETHYLENE CTS PIPE FASTENER Item#Submitted 555 series Tube TalonT" Job Name SPECIFICATION Location Sioux Chief 555 Series Tube Talon'CTS pipe fasteners shall be used where Engineer necessary to secure CTS tube in piping systems. Fastener shall be 100% Contractor corrosion proof and U.V.resistant. Fastener shall be impact resistant to 0°F, Po# TAG and be able to withstand continuous temperatures up to 160°F. Fastener shall have a preloaded nail,which shall be rust resistant,zinc plated yellow irradite. Preloaded nail shall have a continuous ring shank to provide a more permanent installation. Fastener shall snap onto CTS tube for easy installation,and shall allow for expansion and contraction of tube with less noise. Fastener shall be designed to avoid tube damage if nail is over driven. MATERIALS fastener body:High density black polyethylene; 100%corrosion proof; U.V.resistant;impact resistant to 0°F; max temp: 160°F continuous. ri nail: Rust resistant;zinc-plated yellow irradite;continuous ring shank. MAXIMUM LOAD RATING 555-1:3 lbs. 555-2 555-2:5 lbs. 555-3:8 lbs. 555-4: 12 lbs. APPROVED USES Manufacturer has approved the Tube Talon for use with:copper tube,CPVC tube, PEX/PB tube,CSST lines,flexible gas tubing, plastic/steel conduit,low voltage DataCom cable. INSTALLATION Manufacturer suggests the Tube Talon be installed in alternating directions (so that the fastener's nail is on alternating sides of the tube being fastened)to ensure secure installation.Install fasteners at intervals described in local plumbing code for the type of pipe or tube being fastened. E To install IPS tube, use the next larger size fastener,e.g.if you are fastening 1h"IPS tube,use a 3/4"fastener. 1 B DIMENSIONS: 555-1 555-2 555-3 555-4 A A: width 0.848" 1.125" 1.375" 1.6875" F� B: height 0.735" 0.875" 1.1875" 1.4375" C: depth 0.375" 0.375" 0.4375" 0.5" 1 D: nail length 1.625" 1.625" 2.125" 2.375" O C E: hook height 0.468" 0.5625" 0.75" 0.9063" 1 F: width to center of tube 0.5" 0.6563" 0.75" 0.9375" Create Item Number 555-A e.g.555-3=Tube Talon for 3/4"CTS piping A TUBE SIZE ❑ 1 3/8"CTS ❑ 2 Y2'CTS ❑ 3 3/4"CTS ❑ 4 1"CTS Sioux Chief Sioux Chief Manufacturing Company•tel:1-800-821-3944 •www.siouxchief.com •fax:1-800-758-5950 11-08 SPEARS PVC & CPVC TRUE UNION 2000 VALVES TU2000-2-0408 One of the Most Versatile, Compact Valve Designs Available Spears®True Union 2000 Ball Valves,3-Way Ball Valves and Ball Check Valves provide maximum versatility with fully interchangeable valve cartridges.Provides for easier system design modifications and upgrades in multiphase projects,or anywhere changes in valve types are desired.Simply exchange any True Union 2000 valve in-line using existing union nuts. Also mates with Spears® new Schedule 80 Unions and Diaphragm Valves. All True Union 2000 valves feature a low profile, compact design for minimal space requirements. Available in PVC or CPVC with choice of EPDM or Dupont Dow Viton®O-ring seals and socket,flanged, spigot or optional Spears®patented Special Reinforced(SR)threaded end connectors.Additionally, Spears®offers valve Retrofit Kits for easy in-line replacement of other valves and factory installed Actuation Packages.Assembled with silicone-free lubricant. True Union 2000 Industrial Ball Valve • Multi-featured Industrial Grade • Built-in Handle Lockout • Fully Serviceable,Replaceable Components • Safe-T-Blocked®Seal Carrier-Full Rated Pressure _ • ISO Pattern Actuation Mounting Option • Spears®Dual O-ring Safe-T-Shear®Stem • Self Adjusting PTFE Floating Seat Design • Sizes 1/2" -4"pressure rated to 235 psi @ 73°F, sizes 6"-8"and all flanged to 150 psi @ 73°F • NSF Certified for Potable Water Use • Also Available in SPEARS®LXTTm High Purity, Low Extractable PVC Material • Produced in IPS sizes 1/2"-6"with Socket, Flanged,Spigot or SR Threaded End Connectors True Union 2000 Industrial 3-Way Valve • 8"with Socket and Flanged End Connectors • Industrial Grade,Multiport,Diverter,L-Pattern& T Pattern configurations Vertical 3-Way or Horizontal Diverter(shown) • Built-in Handle Lockout • Fully Serviceable,Replaceable Components • Safe-T-Blocked®Seal Carrier-Full Rated Pressure • ISO Pattern Actuation Mounting Option • Spears®Dual O-ring Safe-T-Shear®Stem • Self Adjusting PTFE Floating Seat Design • Sizes 1/2" -2"pressure rated to 235 psi @ 73°F, sizes 2-1/2"-4"and all flanged to 150 psi @ 73°F • NSF Certified for Potable Water Use • Produced in IPS sizes 1/2"-4"with Socket, Flanged, Spigot or SR Threaded End Connectors (LPC)B PROGRESSIVEPRODUCTSFROMSPE"S®INNOVATION&TECHNOLOGY :-a-Viso 9001:2000 T Visit our web site: • Avoid contact with eyes. Splash-proof chemical goggles are recommended. • Review the Material Safety Data Sheet (MSDS) and the important product information provided on the label for Spears®FS-5 One-Step Low VOC Solvent Cement. Failure to follow the above recommendations could result in death or serious personal injury. Listings, Approvals, Application & Use Spears° FlameGuard° CPVC Fire Sprinkler Products are fully tested and approved for use in wet pipe fire sprinkler systems by Underwriters Laboratories Inc., FM Global, and the Loss Prevention Certification Board. Spears® FlameGuard° CPVC Fire Sprinkler Products are approved for use in low pressure dry pipe or pre-action systems by Underwriters Laboratories Inc. Spears° FlameGuard°CPVC Fire Sprinkler Products are listed by NSF® International for use in potable water systems. For specific listing information not covered in this manual concerning Factory Mutual,The Loss Prevention Certification Board or NSF® International, please contact your nearest Spears°Regional Distribution Center. NOTICE: National Fire Protection Association (NFPA) Standards 13, 13R, and 13D must be referenced for design and installation requirements in conjunction with this manual and all local codes. CAUTION: Spears° FlameGuard° CPVC Fire Sprinkler Products are NOT listed for outdoor applications. Outdoor installation could result in product failure and property damage and will not be covered under the Spears° FlameGuard°CPVC Fire Sprinkler Products warranty. CAUTION: Spears° FlameGuard° CPVC Fire Sprinkler Products are to be used in wet pipe systems only, except as provided for dry pipe or pre-action systems in this manual. A wet pipe system is one that contains water and is connected to a water supply system so that the water will discharge immediately when the sprinkler is opened. A low pressure dry pipe or pre- action system is a piping system containing air or nitrogen under pressure that is release with the opening of a sprinkler which activates a special dry pipe valve allowing water to flow into the piping system and to the open sprinkler. WARNING: Spears°FlameGuard°CPVC Fire Sprinkler Products must never be used for distribution of compressed air or other gases except as provided for under Low Pressure Dry Pipe and Pre-action Systems specified in this manual. Failure to follow this warning could result in product failure, property damage and severe personal injury or death. Light Hazard Occupancies Spears®FlameGuard°CPVC Fire Sprinkler Products are UL Listed for use in Light Hazard Occupancies, as defined in the NFPA 13. In accordance with NFPA 13,2002 Edition paragraph 6.3.6.2,`Pipe or tube listed for light hazard occupancies shall be permitted to be installed in ordinary hazard rooms of otherwise light hazard occupancies where the room does not exceed 400 square feet'. NOTICE: Local jurisdictions must approve of this exception. Residential Occupancies Spears°FlameGuard®CPVC Fire Sprinkler Products are UL Listed for use in: Residential occupancies up to and including four stories in height, as defined in NFPA 13R. Residential occupancies, as defined in the Standard for the Installation of Sprinkler Systems in One and Two Family Dwellings and Manufactured Homes, NFPA 13D. FG-3-1010 ©2010 Spears®Manufacturing Company Page 7 ODTOLCO' VVWW.tolco.com Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe �� US LISTED Size Range — 3/4" through 2" Material — Carbon Steel, Pre-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. A • Unique twist and lock design holds pipe firmly in place and allows retrofit type B of installation. C • The "Stand-Off" design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws. �o O • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals—Underwriters' Laboratory Listed in the USA(UL)and Canada(cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satis- fies the UL vertical restraint requirement where needed. UL Listed as a hanger and ver- tical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed O Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper O installed screw when used as a hanger only. } Order by — Figure number and pipe size. Pat.#7,455,268, Pat.#7,832,248 FIG.21B (1)REQUIRED FIG.27B HIGH SIDE (2)REQUIRED OF HANGER O Dimensions•Weights HANGER APPLICATION HANGER&RESTRAINT Pipe Approx. APPLICATION RG.ZB Size B C Wt. 3/4 31/32 2 31/2 .180 1 35/16 23/16 31/2 .210 11/4 35/8 23/8 31/2 .225 11/2 4 21/2 31/2 .310 F1018 2 41/2 211/16 35/3 .340 FI02B FI6Z8 FGn OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX 951.737.0330 m CUSTOMER SERVICE•800.786.5266 www.tolco.com FOR SMALL PIPE POTTERVANE TYPE WATERFLOWCATLARM SWITCH The Symbol of Protection WITH RETARD AND GLUE-IN UNION CUL,UL and CSFM Listed,CE Marked,NYMEA ACCEPTED Service Pressure: Up to 175 PSI(12,07 BAR) Minimum Flow Rate for Alarm: 8-10 GPM(30-38 LPM) Maximum Surge: 18 FPS(5,5 m/s) Enclosure: Die-cast,red powdercoat finish No.1113555:Cover held in place with tamper resistant screws No.1113600- Tamper:Cover incorporates micro-switch. Cover Tamper:Activated by cover removal. Cover Tamper Switch Contacts:One set SPDT,Rated at 250VAC. Cover Tamper Switch Terminations:8"22AWG wire leads. Contact Ratings: Two sets of SPDT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. + Usage: Listed CPVC plastic piping systems manufactured by Central Sprinkler Corp.,Grinnell Sprinkler Corp.,Spears Manufacturing Co.,and IPEX(Scepter). Fits pipe sizes-1",1-1/4",1-1/2"and 2" US Patent No.6,471,255 Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket Stock No. 1113555 and die-cast housing. 1113600 W/TSK • For NEMA 4/IP55 rated enclosure-use with appropriate conduit Service Use: fitting and/or plugs. Automatic Sprinkler NFPA-13 • Temperature range:40'F to 1200 F(4,50 C to 490 C) One or two family dwelling NFPA-13D Caution: This device is not intended for applications in explosive Residential occupancy up to four stories NFPA-13R environments. National Fire Alarm Code NFPA-72 TheMode1VSR-SFG is avane typewaterflow switch foruse onwet sprinkler operation of the VSR-SFG. See Fig. 1.)Wait 2 to 4 hours to allow the systems using CPVC plastic fittings manufactured by Central Sprinkler glue to dry before attaching the VSR-SFG to the 1"male fitting.Select the Corp., Grinnell Sprinkler Corp., Spears Manufacturing Co., and IPEX proper paddle for the pipe size and type of TEE used.See Fig.3 and Fig.5 (Scepter)that use 1",1-1/4", 1-1/2"or 2"pipe sizes.It is equipped with a for instructions on how to change paddle.Verify that the o-ring is properly union to accommodate installation in confined spaces. positioned in its groove.Hand tighten the nut on the union after orienting the The unit contains two single pole double throw snap action switches and an device in the appropriate direction to detect waterflow as shown in Fig.2. adjustable,instantly recycling pneumatic retard.The switches are actuated CAUTION:Do not over-tighten the union nut,hand tighten only! when a flow of 8-10 gallons per minute(30-38 liters per minute)or more The vane must not rub the inside of the TEE or bind in any way.The stem occurs downstream of the device.The flow condition must exist for a period should move freely when operated by hand. of time necessary to overcome the selected retard period. INSPECTION AND TESTING:Check the operation ofthe unit by opening INSTALLATION:These devices maybe mounted on horizontal or vertical the inspector's test valve at the end of the sprinkler line or the drain and test pipe.On horizontal pipe they should be installed on the top side of the pipe connection,if an inspector's test valve is not provided. where they will be accessible.The units should not be installed within 6"(15 cm)of a valve,drain or fitting which changes the direction of the waterflow. If there are no provisions for testing the operation of the flow detection The unit has a 1"male fitting for gluing into a CPVC plastic TEE. device on the system,application of the VSR-SFG is not recommended or advisable. Loosen the union nut and separate the 1"male fitting from the VSR-SFG. Glue the 1"male fitting into the TEE following the TEE manufacturer's The frequency of the inspection and testing and its associated protective instructions for preparation and gluing of CPVC piping systems.(NOTE: monitoring system should be in accordance with the applicable NFPA The 1"male fitting must bottom out on the stop of the TEE for proper Codes and Standards and/or authority having jurisdiction(manufacturer recommends quarterly or more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT.#8800009-REV P PAGE 1 OF 2 MFG.#5401062-11105 FOR SMALL PIPE VSR-SF P0TT8Z VANE TYPE WATERFLOW ALARM SWITCH ® The Symbol of Protection WITH RETARD AND GLUE-IN UNION FIG.I FIG.2 APPROX.RETARD SETTINGS(IN SEC.) Retard Adjustment: 0 A B C D E 0• 0 10-25 20-40 35-55 50-70 60-90 (MINIMUM CLEARANCE TO change time,turn knob(either direction) REQUIRED FOR 1" MALE FITTING INSTALLATION OR MUST BOTTOM OUT for desired time delay. Use the minimum DO NOT LEAVE COVER REMOVAL OF DEVICE) ON STOP amount of retard necessary to prevent false PERIOD OFOFF FOR XIMEN E ED alarms.A`B"setting is usually adequate for this.Factory set at`B". RETARD FIG.3 ADJUKNINNGG (WHITE) COM. OB (RED) N.O. (BLACK) N.C. DIRECTION OF MOUNT SO _ WATERFLOW ARROW ON \ CAUTION: INSURE BASE POINTS THAT 0-RING IS IN DIRECTION N O-RING GROOVE OF WATERFLOW BEFORE INSTALLING NO BUSHINGS, DWG.0063-3 SWITCH. INSERTS OR DWG. #1062-1 Im Important:ADAPTERS p ARE PERMITTED 7 paddles are furnished with each unit 1" MALE to accommodate the various sizes and RUN OF THE FITTING ON TEE MAY BE ALL SIZES Glue the 1"male fitting into the TEE following manufacturers of TEES.The paddles have 1„ 1 1/4" the TEE manufacturer's instructions for raised lettering that show the pipe size and 1 1/2" OR 2" preparation and gluing of CPVC piping the TEE manufacturer they are to be used DIRECTION OF systems.Wait 2 to 4 hours to allow the glue with.The proper paddle must be used.The wATERFLOW DWG. #1 osz-z to dry before attaching the VSR-SFG to the paddle must be properly attached(see Fig.3) 1"male fitting. and the screw that holds the paddle must be Shown with optional Cover securely tightened. Tamper Switch Kit. FIG.4 TYPICAL ELECTRICAL CONNECTIONS NOTES: COVER TAMPER 2 SETS OF NORMALLY OPEN CONTACTS WATERFLOW— EOLR FROM 1. The model VSR-SFG has two SWITCH CLOSEONALARM ONE—PANEL FIRE PANEL switches,one can used to operate a (SHOWN WITH central station,proprietary or remote COVER IN PLACE) signaling unit,while the other is used to operate a local audible or visual �Tl © annunciator. THE N.C.AND N.O.MARKINGS ON POSITIVE DC 2. For supervised circuits see"Switch THESwITCHAREFORAN ALARM ORHOTAC C N.O. N.C. CONDITION. BELL Terminal Connections"drawing and (WHT) (RED) BLK> NEGATIVE DC OR THE CONTACTS ARE REVERSED NEUTRALAC caution note(Fig.6). owa eaiaoisx WHEN THE DEVICE IS❑i TITS NORMAL CONDITION. owcp�5i-x FIG.5 GRINNELL TEE FIG.6 SWITCH TERMINAL CONNECTIONS TEE's manufactured prior TEE's manufactured CLAMPING PLATE TERMINAL to 5/99 after 5/99 ,ny �1 d �OQaG OWGp 923-3 NOTICE: DWG,;ttoss-a O As of 5/99 Grinnell has changed the design of their TEE fittings.The new fittings CAUTION: will require the use of the standard paddle,while you will still be required to An uninsulated section of a single conductor should not be looped around the use the paddle marked Grinnell on all fittings manufactured prior to this date. terminal and serve as two separate connections.The wire mustbe severed,thereby Failure to install the correct paddle could cause the device to malfunction or providing supervision of the connection in the event that the wire becomes operate improperly. dislodged from under the terminal. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges,trapped air,or short retard times,waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF,deluge,or chemical suppression systems. PRINTED IN USA MKT.#8800009-REV P PAGE 2 OF 2 MFG.#5401062-11105 �, SYSTEM �4 SENSOR' Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert®Advance outdoor audible visible products SPECTRAiert are rich with features that cut installation times and A Q V A IV C E maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed devices,SpectrAlert Advance can meet virtually any application Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151°F. Field-selectable candela settings:15,15/75,30,75,95,110,115,135, 150,177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes,and Automatic selection of 12-or 24-volt operation at 15 and 15/75 horn strobes for wall applications include a variety of features that candela increase application flexibility and simplify installation.First,field- Rotary switch for horn tone and three volume selections selectable settings,including candela,automatic selection of 12-or 24-volt operation,horn tones,and three volume options enable Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. Rated from—40°F to 151°F Universal mounting plate with an onboard shorting spring that Next,SpectrAlert Advance devices use a universal mounting plate tests wiring continuity before devices are installed for both wall and ceiling applications.This mounting plate includes an onboard shorting spring that ensures wiring continuity before Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without -Tamper-resistant construction mounting the devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING w corrosion.Knock-outs located on the back eliminate the need to drill O ° i holes for screw-in mounting.Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED F nn MEA 7300.1653:1a7(horn st obesb strobes) 54011(chimes,horn strobes,horns) APPROVED approved 7,25-,653:,88(himessSObes) knock-outs at the back.Ascrew-in NPT plug with an O-ring gasket S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. LOWN-IN INSULATION It Requires insulation be moved up above the sprinkler pipe to 0 0 0 0 0 allow heat from the conditioned O O O O O O space below to transfer into the O O O O O O O O O O attic space and keep the pipe O O O O O _ O O O O warm. O-0 O-0 O�O� �O�O�O�O O0 00000 0000000. O O O O O O 0 TRAPPED AIR SPACE 10 MIL PLASTIC TENTED OVER PIPING (STAPLE BATTS INSULATION (TRAPPED AIR SPACE OR PLASTIC"TENT") BATT INSULATION TENTED OVER PIPING TENTING TENTING(Fig.1) L T,..� C'� °r �`•' try,-. I TENTING A common method used for insulating sprinkler piping sections that are run within any unconditioned space, such as an attic or an exterior wall. It Requires insulation be moved up above the sprinkler pipe to allow heat from the conditioned space below to transfer into the attic space and keep the pipe warm. For it to be effective the insulation must be continuous over the pipe, with the assumption that any heat lost through the insulation will be replaced by the conditioned space. Even in moderate climates, the sprinkler system needs to be protected from freezing. This is done by keeping the sprinkler pipe inside the insulation envelope. Figure 1 shows tenting over residential sprinkler pipes to prevent blown insulation from getting between the pipe and building's warmth. ► 1 1 liq E.S l .J O X C US Drinking Water ELECTRONIC PRESSURISATION SYSTEM NSF /ANSI 61 �9 cm k E.SYBOX ELECTRONIC PRESSURISATION SYSTEM TECHNICAL DATA Operating range: capacity up to 32 gpm;head up to 213 ft(86 psi) — Liquid quality requirements:clean,free from solid or abrasive contaminants, non-viscous,non-aggressive,uncrystallised and chemically neutral. Liquid temperature range:from 320F to+950F for domestic use for other use:from 32°F to+104°F •, Maximum suction depth:26 ft t Maximum ambient temperature:+122°F Maximum pressure:115 psi — Maximum setable pressure:85 psi Motor protection rating:IPX4 Insulation class:F Installation:Horizontal or vertical fixed position Approvals:CSA certification to CSA Standard C22.2 No 108-14 Liquid Pumps. LIL Standard 778-5th Edition-Motor operated water pumps NSF/ANSI 61 -2O14a-Drinking Water System Components—Health Effects NSF/ANSI 372-2011 -Drinking Water System Components—Lead Content Special versions on request:alternative types of electrical plug APPLICATIONS E.SYBOX is DAB's integrated electronic water pressurisation system for domestic and residential use.The E.SYBOX inverter system provides the comfort of constant water pressure,while saving energy too.Suitable for use for potable water, in domestic plants for gardening and irrigatio.Suitable for creating groups of up to 4 pumps. E.SYBOX requires no additional components for installation. CONSTRUCTIONAL FEATURES E.SYBOX comprises a self-priming, multi-stage pump with electronic inverter management, pressure and flow sensors, adjustable, high resolution LCD display and an integrated 1/4 gal expansion vessel,and cartridge check valve. May be installed either vertically or horizontally, in closed spaces without high level of air exchange.The accessories(e.sywall,e.sydock, e.sytwin,e.sytank) permit several installation possibilities. The water-cooled motor,the protective and sound damping ABS hull,the anti-vibration feet and its electronics make this compact poroduct very quiet(45dB under normal use).The wireless system enables the creation of other pressurisation groups able to connect with other DAB devices(eg,e.sylink). The constant pressure can be set from 15 to 85 psi. Fitted with all the safety protections,as well as the protections for the safeguard of the pump.Particularly,the dry run,and the antifreeze protections. All the parameters and the operating status can be displayed and set on the high resolution LCD display. MATERIALS o No PARTS* MATERIALS 14 1 MOTORFLANGE TECHNOPOLYMER 2 ROTOR SHAFT AISI 303 STAINLESS STEEL 3 MOTOR JACKET AISI 304 STAINLESS STEEL 5 OR GASKET NBR 0 7 SINTERED PLATE AISI 304 STAINLESS STEEL 11 1"PLUG TECHNOPOLYMER 1 13 SUCTION BODY TECHNOPOLYMER 14 1"INSERT NICKLED BRASS 1 {, 15 SHUTTER TECHNOPOLYMER 17 SPRING AISI 303 STAINLESS STEEL 13 20 DIFFUSER TECHNOPOLYMER 21 DIFFUSER BODY TECHNOPOLYMER 22 IMPELLER TECHNOPOLYMER 1 22c SHIM RING AISI 316 STAINLESS STEEL 11 1 5 1 5 2 28 3 1 24 NUT AISI 316 STAINLESS STEEL 2 25 DIFFUSER END PLUG TECHNOPOLYMER 27 MECHANICAL SEAL CARBON IMPREGNATED RESIN/ SILICON CARBIDE/EPDM ©56 0 28 PUMP BODY TECHNOPOLYMER 30 DISCHARGE BODY TECHNOPOLYMER 36 FLOW SWITCH BODY TECHNOPOLYMER 41 PRESS.STABLE.IMPELLER TECHNOPOLYMER 46 DISCHARGE MANIFOLD TECHNOPOLYMER 47 1"1/4 PLUG TECHNOPOLYMER 52 NON-RETURN VALVE TECHNOPOLYMER/RUBBER/STEEL 57 TANK TECHNOPOLYMER/RUBBER 0 58/1 PRESSURE SENSOR BODY TECHNOPOLYMER `In contact with liquid 36 41 44 46 4 E3.4 B DAB PUMPS reserves the right to make modifications without notice. W A T E H-T E C H N 0 L 0 6 Y E.SYBOX-ELECTRONIC PRESSURISATION SYSTEM FOR DOMESTIC WATER SUPPLY Liquid temperature range:from 320F to+950F for domestic use-from 320F to+1040F for other uses. Maximum ambient temperature:+1220F P o 5 10 15 20 25 30 Q US gpm PSI H H m R lot- 70 88 60 200 B �v 72 50 160 � 5a ao 1zo A a4 30 as 29 20 H 40 la 10 I ® o 0 0 0 1 2 3 4 5 6 7 Q m3/h 0 0,5 1 1,5 2 Q I/s 0 20 40 60 80 100 120 Q I/min D 0 5 10 15 20 25 30 Q US gpm o s 10 15 20 25 QIMPgpm kW E 1,6 F G 1,4 1,2 Oo Oo 1,0 -11010 OF 0,6 8 0,4 0 o M 0,2 0 0 1 2 3 4 5 6 7 Q m3/h 0 0,5 1 1,5 2 Q I/5 0 20 40 60 80 100 120 Q I/min The performance curves are based on the kinematic viscosity values= 1 mm2/s and density equivalent to 1000 kg/m3.Curve tolerance according to ISO 9906. Q=gpm 0 2.6 5.3 7.9 10.6 13.2 15.8 18.5 21.1 23.8 26.4 29.0 31.7 MODEL Q=Vmin 0 10 20 30 40 50 60 70 80 90 100 110 120 E.SYBOX H=(ft) 213 208 203 195 187 174 157 136 115 90 62 33 7 ELECTRICAL DATA MODEL No POWER SUPPLY P1 MAX In IMPELLER 50/60 Hz kW HP A E.SYBOX 5 230 V- 1.55 2.11 10.0 MODEL A B C D E F G 10 H L M DNA DNM PACK DIMENSIONS GROSS L/A L/B H Ibs 22.20" 10.35" 2.56" 5.18" 4.17" 2.24" 4.97" 0.35" 14.25" 2.76" 6.50" 1"NPT 1"NPT 26.97" 14.17" 19.29" 59.52 E)A B DAB PUMPS reserves the right to make modifications without notice. W A T E B-T E C H N 0 L 0 G Y *********** DAB PUMPS INC. *********** *********** *********** 3226 Benchmark Drive a w■ 'W1 ,i Ladson, SC 29456 - USA PUMPS SELECTOR www.dabpumps.us p info.usa@dwtgroup.com Tel. 1-843-797-5002 0 Fax1-843-797-3366 J LZ DAB PUMPS LTD. DAB PUMPS IBERICA S.L. DAB PUMPS INC. Unit 4 and 5,Stortford Hall Industrial Park, Avenida de Castilla nr.1 Local 14 3226 Benchmark Drive Dunmow Road, 28830-San Fernando De Henares-Madrid Ladson,SC 29456-USA Bishops Stortford, Spain info.usa@dwtgroup.com Herts info.spain@dwtgroup.com http:Hus.dabpumps.com CM23 5GZ-UK Tel.+34 91 6569545 Tel.1-843-797-5002 salesuk@dwtgroup.com Fax:+34 91 6569676 Fax 1-843-797-3366 Tel.+44 1 279 652 776 Fax+44 1279 657 727 DAB PRODUCTION HUNGARY KFT. H-8800 Nagykanizsa,Buda Ern6 u.5 DAB PUMPS B.V. Hungary DWT SOUTH AFRICA Brusselstraat 150 Tel.+36 93501700 Podium at Menlyn, B-1702 Groot-Bijgaarden-Belgium 3rd Floor,Unit 3001b,43 Ingersol Road, info.belgium@dwtgroup.com C/O Lois and Atterbury street, Tel.+32 2 4668353 Menlyn,Pretoria,0181-South-Africa Fax+32 2 4669218 info.sa@dwtgroup.com DAB PUMPS POLAND Sp. z o.o. Tel.+27 12 3613997 Mokotow Marynarska Fax+27 12 3613137 ul.Post pu 15C 02-676 Warszawa-Poland Tel.+48 223 816085 DAB PUMPS B.V. DAB PUMPS CHINA Albert Einsteinweg,4 No.40 Kaituo Road,Qingdao Economic&Technological 5151 DL Drunen-Nederland Development Zone info.netherlands@dwtgroup.com DAB UKRAINE Representative Office Qingdao City,Shandong Province-China Tel.+31 416 387280 Regus Horizon Park PC:266500 Fax+31 416 387299 4 M.Hrinchenka St,suit 147 info.china@dwtgroup.com 03680 Kiev-Ukraine Tel.+8653286812030-6270 Tel.+38 044 39159 43 Fax+8653286812210 _ DAB PUMPEN DEUTSCHLAND GmbH 000 DAB PUMPS B DAB PUMPS DE MUICO,S.A.DE C.V. Tackweg 11 Novgorodskaya str.1,block G Av Gral Alvaro Obreg6n 270,oficina 355 D-47918 T6nisvorst-Germany office 308,127247,Moscow-Russia Hip6dromo,Cuauht6moc 06100 info.germany@dwtgroup.com info.russia@dwtgroup.com Mexico,D.F. Tel.+49 2151 82136-0 Tel.+7 495 122 0035 Tel.+52 55 6719 0493 Fax+49 2151 82136-36 Fax+7 495 122 0036 0 m N n O O 16" DIA. VENTED LID 35' DIA. 16" DIA. VENTED LID r, oOoo TOP VIEW I" FRICTION WELDED PIPE CONNECTION 35" DIA. SIDE ELEVATION NOTE: OPTIONAL THRU-HULL FITTINGS ARE AVAILABLE UPON REQUEST PPREM/ER UTILITY STORAGE TANK DATE: MAY 2010 PLASTICS INC . SCALE: 1:12 MANUFACTURER$OF ROTATIONALLY MOULDED PRODUCT$ 300 US. GALLON - UT35-300 DRAWN: SGM 8328 River Way Toll Free:1-800-661-4473 240 IMP. GALLON DWG. No. UT35-300 Delta,BC,Canada Bus:(604)952-6686 V4G 1C4 Fax:(604)952-6696 www.premierplastics.com E-mail:premier@ultranet.ca I POLYETHYLENE REV. CITY OF ANACORTES FIRE DEPARTMENT APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT#: BLD-2022-0650 ADDRESS: 3949 ROCK RIDGE PKWY APPROVED BY: Bill Harris SUBJECT TO FIELD INSPECTION.APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. Fire Sprinkler System Calculations X-Fire Security 1511 Kentucky Street,Bellingham WA Job No: L-3905 Job Name: Weisberg-Price Residence Building Type: Single Family Residence Location: 3949 Rock Ridge Pkwy.Anacortes WA System Type: NFPA 13D 2019 i■s■rr������rrr�����rAA/AA�i: - ■ WA HEIGn"*rATE r 651MCATV Or Wr■Pl EW i ■ R�'Iq"rtC770i1tlWMKLARSIrT� ■ ■ E Charlle Johnathan Rimer c� • 4425-0422-A Levels ` a, ■ X-Fire s. XFIRE-961 PN • r tarns • r ■rsr■■■■arrsssr■■rrr��rrrrrs■ Designed by X-Fire Security- 1511 Kentucky Street,Bellingham WA- 360-715-8088 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 2 of 10 Final Calculations -Summary Wednesday, August 10, 2022 Hydraulic Design Information Sheet Job Name Weisberg-Price Residence Opened Date 8/10/2022 Location 3949 Rock Ridge Pkwy.Anacortes WA Job No L-3905 Building Type Single Family Residence Ceiling Height (ft) 9 Calculated By Charlie Rimer Construction Combustible Occupancy Residential System Design Type of Calculation NFPA 13D 2019 Listed Flow at Start Point(gpm) 13.000 System Type Wet Listed Pressure at Start Point (ps 9.100 Sprinkler Make Reliable Maximum Listed Spacing (ft) 16 Sprinkler Model RFC43 Domestic Flow(gpm) 0.000 Sprinkler Size (in) 0.50 Elevation at Highest Outlet(ft) 489 Sprinkler K-Factor 4.3 Temp. Rating (°F) 165 Coverage Area (ft') 256 Listed Flow (gpm) 13.000 Calculation Summary Flowing Sprinkler Heads H.34 H.38 Flow Required (gpm) 26.000 Pressure Required (psi) 39.567 At Reference Point PUMP Overhead C-Factor Used 150 Underground C-Factor Used 150 Water Supply Water Flow Test: Static Pressur 65.000 Residual Pres 60.000 Flow (gpm) 32.000 Elevation (ft) 453 Manifold &Water Flow Switch Additional Pressure Loss (psi) 4.60 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 3 of 10 Final Calculations -Water Supply Curve Wednesday, August 10, 2022 100 90 80 70 60 "" ■ 50 ■ ■ ■ 40 ' 30 20 .N 10 m CL 0 5 10 15 20 25 30 35 40 Flow(N 1.85 �(gpm) e---e Demand Curve Required Pressure: 39.567 psi @ 26.000 gpm Required Flow: 26.000 gpm G-----O Supply Curve Static Pressure: 65.000 psi @ 0.000 gpm Residual Pressure: 60.000 psi @ 32.000 gpm Available Flow: 32.000 gpm >4 ■ ■ ■ ■• Pressure Cushion Available Pressure: 61.595 psi @ 26.000 gpm Pressure Cushion: 22.028 psi L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 4 of 10 Final Calculations - Nodes Wednesday, August 10, 2022 Actual Actual Elev. Press. Flow Node No. (ft) (psi) (gpm) Model-Coverage(DxW)-Temperature S.0 455.0 34.028 0.000 SOURCE H.1 463.0 30.388 0.000 RFC43-1616-165 D.T.1 463.0 30.232 0.000 Rehau PEX 1.00in Dom Tee L.1 463.0 30.493 0.000 CPVC 1.50in 90 Ell T.1 463.0 30.198 0.000 CPVC 1.598x1.598x0.875in Tee R.1.A 463.0 29.833 0.000 H.2 463.0 30.458 0.000 RFC43-1616-165 D.T.2 474.0 24.644 0.000 Rehau PEX 1.00in Dom Tee R.2.A 474.0 24.871 0.000 L.2 463.0 30.077 0.000 CPVC 1.50in 90 Ell T.2 474.0 24.675 0.000 CPVC 1.598x1.598x0.875in Tee H.3 463.0 30.521 0.000 RFC43-1212-165 D.T.3 474.0 24.651 0.000 Rehau PEX 1.00in Dom Tee L.3 463.0 29.911 0.000 CPVC 1.50in 90 Ell R.3.B 474.0 24.423 0.000 T.3 474.0 24.640 0.000 CPVC 1.598x1.598x0.875in Tee HA 463.0 30.223 0.000 RFC43-1616-165 LA 474.0 24.794 0.000 CPVC 1.50in 90 Ell R.4.B 485.0 19.461 0.000 TA 485.0 19.280 0.000 CPVC 1.598x1.598x0.875in Tee D.T.4 485.0 19.057 0.000 Rehau PEX 1.00in Dom Tee H.5 463.0 30.511 0.000 RFC43-1212-165 L.5 474.0 24.500 0.000 CPVC 1.50in 90 Ell T.5 485.0 19.232 0.000 CPVC 0.875x0.875x1.598in Tee H.6 463.0 30.549 0.000 RFC43-1818-165 L.6 485.0 19.379 0.000 CPVC 1.50in 90 Ell T.6 487.0 16.012 0.000 Rehau PEX 0.8750.8750.875in Tee H.7 463.0 30.267 0.000 RFC43-1616-165 T.7 487.0 14.045 0.000 Rehau PEX 0.8750.8750.875in Tee H.8 463.0 30.324 0.000 RFC43-1616-165 T.8 487.0 13.946 0.000 Rehau PEX 0.8750.8750.875in Tee H.9 463.0 30.298 0.000 RFC43-1616-165 H.10 463.0 30.487 0.000 RFC43-1616-165 H.11 474.0 24.652 0.000 RFC43-1212-165 H.12 474.0 24.646 0.000 RFC43-1616-165 H.13 474.0 24.656 0.000 RFC43-1212-165 H.14 474.0 24.656 0.000 RFC43-1212-165 H.15 474.0 24.654 0.000 RFC43-1616-165 H.16 474.0 24.645 0.000 RFC43-1616-165 H.17 474.0 24.653 0.000 RFC43-1616-165 H.18 474.0 24.672 0.000 RFC43-2020-165 H.19 474.0 24.642 0.000 RFC43-1818-165 H.20 474.0 24.643 0.000 RFC43-1616-165 H.21 463.0 30.418 0.000 RFC43-1616-165 H.22 463.0 30.365 0.000 RFC43-1212-165 H.23 474.0 24.650 0.000 RFC43-1212-165 H.24 485.0 18.126 0.000 RFC43-1616-165 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 5 of 10 Final Calculations - Nodes Wednesday, August 10, 2022 Actual Actual Elev. Press. Flow Node No. (ft) (psi) (gpm) Model-Coverage(DxW)-Temperature H.25 485.0 18.471 0.000 RFC43-1616-165 H.26 485.0 17.631 0.000 RFC43-1616-165 H.27 485.0 16.991 0.000 RFC43-1616-165 H.28 485.0 17.925 0.000 RFC43-1616-165 H.29 485.0 19.057 0.000 RFC43-2020-165 H.30 487.0 16.053 0.000 RFC43-1616-165 H.31 487.0 16.253 0.000 RFC43-1616-165 H.32 487.0 16.447 0.000 RFC43-1616-165 H.33 487.0 16.614 0.000 RFC43-1616-165 H.34 489.0 9.100 13.000 RFC43-1616-165 H.35 489.0 11.364 0.000 RFC43-1616-165 H.36 489.0 12.603 0.000 RFC43-1616-165 H.37 489.0 13.659 0.000 RFC43-1616-165 H.38 489.0 9.100 13.000 RFC43-1616-165 H.39 487.0 12.742 0.000 RFC43-1616-165 H.40 474.0 24.660 0.000 RFC43-1616-165 H.41 474.0 24.667 0.000 RFC43-1616-165 H.42 474.0 24.658 0.000 RFC43-1616-165 H.43 474.0 24.670 0.000 RFC43-1616-165 H.44 487.0 13.996 0.000 F3QR56-Dry Horizontal Sidewall H.45 474.0 24.648 0.000 F1R44A6-1616-155 H.46 485.0 18.770 0.000 RFC43-2020-165 FT.34 489.0 10.133 0.000 Rehau PEX 1.00in Sprinkler Tee FT.38 489.0 10.133 0.000 Rehau PEX 1.00in Sprinkler Tee L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 6 of 10 Final Calculations - Pipes Wednesday, August 10, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p47 S.0 -24.347 0.875 6.554 30.549 to 150 1 H 0.500 3.465 Vel = 0.9 H.6 1.653 0.0021 0.00 7.054 0.015 sup0 PUM 0.000 1.598 4.000 34.028 to 150 MNF 0.000 0.866 Vel = 4.2 S.0 26.000 0.0180 4.60 4.000 0.072 p13 H.6 0.000 0.875 12.362 30.521 to 150 2H 1.000 0.000 Vel = 0.9 H.3 1.653 0.0021 0.00 13.362 0.028 p8 H.3 0.000 0.875 4.108 30.511 to 150 2H 1.000 0.000 Vel = 0.9 H.5 1.653 0.0021 0.00 5.108 0.011 p12 H.5 0.000 0.875 10.578 30.487 to 150 2H 1.000 0.000 Vel = 0.9 H.10 1.653 0.0021 0.00 11.578 0.024 p9 H.10 0.000 0.875 12.843 30.458 to 150 2H 1.000 0.000 Vel = 0.9 H.2 1.653 0.0021 0.00 13.843 0.029 p6 H.2 0.000 0.875 18.191 30.418 to 150 2H 1.000 0.000 Vel = 0.9 H.21 1.653 0.0021 0.00 19.191 0.040 p4 H.21 0.000 0.875 13.513 30.388 to 150 2H 1.000 0.000 Vel = 0.9 H.1 1.653 0.0021 0.00 14.513 0.030 p2 H.1 0.000 0.875 10.402 30.365 to 150 2H 1.000 0.000 Vel = 0.9 H.22 1.653 0.0021 0.00 11.402 0.024 p5 H.22 0.000 0.875 18.951 30.324 to 150 2H 1.000 0.000 Vel = 0.9 H.8 1.653 0.0021 0.00 19.951 0.041 p3 H.8 0.000 0.875 11.247 30.298 to 150 2H 1.000 0.000 Vel = 0.9 H.9 1.653 0.0021 0.00 12.247 0.025 p7 H.9 0.000 0.875 14.136 30.267 to 150 2H 1.000 0.000 Vel = 0.9 H.7 1.653 0.0021 0.00 15.136 0.031 p11 H.7 0.000 0.875 15.673 30.232 to 150 1 H 1 R 1.200 0.000 Vel = 0.9 D.T.1 1.653 0.0021 0.00 16.873 0.035 p10 D.T.1 0.000 0.875 3.122 30.223 to 150 1 H 1 R 1.200 0.000 Vel = 0.9 HA 1.653 0.0021 0.00 4.322 0.009 p53 HA 0.000 0.875 4.227 30.198 to 150 1 B1 H 8.000 0.000 Vel = 0.9 T.1 1.653 0.0021 0.00 12.227 0.025 p14 FT.38 12.891 0.875 17.283 12.742 to 150 1 R1 H 1.000 0.866 Vel =-7.0 H.39 -13.109 0.0953 0.00 18.283 1.743 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 7 of 10 Final Calculations - Pipes Wednesday, August 10, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p19 H.39 0.000 0.875 4.624 13.946 to 150 1 B1 H 8.000 0.000 Vel = -7.0 T.8 -13.109 0.0953 0.00 12.624 1.204 p70 T.6 -21.052 0.875 1.251 16.053 to 150 1 H 1 R 1.200 0.000 Vel = -2.8 H.30 -5.166 0.0170 0.00 2.451 0.042 p15 H.30 0.000 0.875 10.732 16.253 to 150 2H 1.000 0.000 Vel = -2.8 H.31 -5.166 0.0170 0.00 11.732 0.200 p16 H.31 0.000 0.875 10.387 16.447 to 150 2H 1.000 0.000 Vel = -2.8 H.32 -5.166 0.0170 0.00 11.387 0.194 p17 H.32 0.000 0.875 8.837 16.614 to 150 2H 1.000 0.000 Vel = -2.8 H.33 -5.166 0.0170 0.00 9.837 0.168 p26 H.33 0.000 0.875 7.849 17.631 to 150 2H 1.000 0.866 Vel = -2.8 H.26 -5.166 0.0170 0.00 8.849 0.151 p28 H.26 0.000 0.875 28.036 18.126 to 150 2H 1.000 0.000 Vel = -2.8 H.24 -5.166 0.0170 0.00 29.036 0.494 p29 H.24 0.000 0.875 19.273 18.471 to 150 2H 1.000 0.000 Vel =-2.8 H.25 -5.166 0.0170 0.00 20.273 0.345 p27 H.25 0.000 0.875 16.566 18.770 to 150 2H 1.000 0.000 Vel =-2.8 H.46 -5.166 0.0170 0.00 17.566 0.299 p62 H.46 0.000 0.875 15.816 19.057 to 150 2H 1.000 0.000 Vel =-2.8 H.29 -5.166 0.0170 0.00 16.816 0.286 p57 H.29 0.000 0.875 9.115 19.232 to 150 1 H 1 R 1.200 0.000 Vel =-2.8 T.5 -5.166 0.0170 0.00 10.315 0.176 p18 T.8 -17.847 0.875 0.984 14.045 to 150 2R 1.400 0.000 Vel =-4.5 T.7 -8.372 0.0416 0.00 2.384 0.099 p21 T.7 -21.481 0.875 2.223 13.996 to 150 1 R1 H 1.200 0.000 Vel = 2.5 H.44 4.737 0.0145 0.00 3.423 0.050 p20 H.44 0.000 0.875 2.211 13.946 to 150 1 H 1 R 1.200 0.000 Vel =2.5 T.8 4.737 0.0145 0.00 3.411 0.049 p22 T.7 -13.109 0.875 12.422 16.012 to 150 1 B1 R 8.200 0.000 Vel =-7.0 T.6 -13.109 0.0953 0.00 20.622 1.966 p69 T.2 -51.659 0.875 17.650 24.672 to 150 1 B1 H 8.000 0.000 Vel = 0.2 H.18 0.341 0.0001 0.00 25.650 0.003 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 8 of 10 Final Calculations - Pipes Wednesday, August 10, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p35 H.18 0.000 0.875 20.030 24.670 to 150 2H 1.000 0.000 Vel = 0.2 H.43 0.341 0.0001 0.00 21.030 0.002 p31 H.43 0.000 0.875 19.610 24.667 to 150 2H 1.000 0.000 Vel = 0.2 H.41 0.341 0.0001 0.00 20.610 0.002 p38 H.41 0.000 0.875 60.090 24.660 to 150 2H 1.000 0.000 Vel = 0.2 H.40 0.341 0.0001 0.00 61.090 0.007 p30 H.40 0.000 0.875 17.793 24.658 to 150 2H 1.000 0.000 Vel = 0.2 H.42 0.341 0.0001 0.00 18.793 0.002 p37 H.42 0.000 0.875 16.940 24.656 to 150 2H 1.000 0.000 Vel = 0.2 H.14 0.341 0.0001 0.00 17.940 0.002 p36 H.14 0.000 0.875 5.552 24.656 to 150 2H 1.000 0.000 Vel = 0.2 H.13 0.341 0.0001 0.00 6.552 0.001 p39 H.13 0.000 0.875 10.610 24.654 to 150 2H 1.000 0.000 Vel = 0.2 H.15 0.341 0.0001 0.00 11.610 0.001 p40 H.15 0.000 0.875 12.772 24.653 to 150 2H 1.000 0.000 Vel = 0.2 H.17 0.341 0.0001 0.00 13.772 0.002 p41 H.17 0.000 0.875 8.375 24.652 to 150 2H 1.000 0.000 Vel = 0.2 H.11 0.341 0.0001 0.00 9.375 0.001 p42 H.11 0.000 0.875 3.658 24.651 to 150 1 H 1 R 1.200 0.000 Vel = 0.2 D.T.3 0.341 0.0001 0.00 4.858 0.001 p43 D.T.3 0.000 0.875 8.232 24.650 to 150 1 H 1 R 1.200 0.000 Vel = 0.2 H.23 0.341 0.0001 0.00 9.432 0.001 p44 H.23 0.000 0.875 21.933 24.648 to 150 2H 1.000 0.000 Vel = 0.2 H.45 0.341 0.0001 0.00 22.933 0.003 p45 H.45 0.000 0.875 9.769 24.646 to 150 2H 1.000 0.000 Vel = 0.2 H.12 0.341 0.0001 0.00 10.769 0.001 p46 H.12 0.000 0.875 10.022 24.645 to 150 2H 1.000 0.000 Vel = 0.2 H.16 0.341 0.0001 0.00 11.022 0.001 p33 H.16 0.000 0.875 6.858 24.644 to 150 1 H 1 R 1.200 0.000 Vel = 0.2 D.T.2 0.341 0.0001 0.00 8.058 0.001 p34 D.T.2 0.000 0.875 8.237 24.643 to 150 1 R1 H 1.200 0.000 Vel = 0.2 H.20 0.341 0.0001 0.00 9.437 0.001 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 9 of 10 Final Calculations - Pipes Wednesday, August 10, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p32 H.20 0.000 0.875 13.845 24.642 to 150 2H 1.000 0.000 Vel = 0.2 H.19 0.341 0.0001 0.00 14.845 0.002 p68 H.19 0.000 0.875 8.166 24.640 to 150 1 H 1 B 8.000 0.000 Vel = 0.2 T.3 0.341 0.0001 0.00 16.166 0.002 p66 T.2 -26.000 1.598 2.610 24.794 to 150 1 R1 L 4.000 0.000 Vel = -4.2 LA -26.000 0.0180 0.00 6.610 0.119 p64 LA 0.000 1.598 0.755 24.871 to 150 1 L 3.500 0.000 Vel = -4.2 R.2.A -26.000 0.0180 0.00 4.255 0.077 i0 R.2.A 0.000 1.598 11.000 29.833 to 150 0.000 4.764 Vel =-4.2 R.1.A -26.000 0.0180 0.00 11.000 0.198 p49 R.1.A 0.000 1.598 0.833 29.911 to 150 1 L 3.500 0.000 Vel = -4.2 L.3 -26.000 0.0180 0.00 4.333 0.078 p50 L.3 0.000 1.598 2.216 30.077 to 150 2L 7.000 0.000 Vel =-4.2 L.2 -26.000 0.0180 0.00 9.216 0.166 p51 L.2 0.000 1.598 2.515 30.198 to 150 1 R1 L 4.200 0.000 Vel =-4.2 T.1 -26.000 0.0180 0.00 6.715 0.121 p67 T.3 -26.000 1.598 3.753 24.500 to 150 1 R1 L 4.000 0.000 Vel =4.2 L.5 26.000 0.0180 0.00 7.753 0.140 p65 L.5 0.000 1.598 0.755 24.423 to 150 1 L 3.500 0.000 Vel = 4.2 R.3.B 26.000 0.0180 0.00 4.255 0.077 i 1 R.3.B 0.000 1.598 11.000 19.461 to 150 0.000 4.764 Vel =4.2 RA.B 26.000 0.0180 0.00 11.000 0.198 p54 RA.B 0.000 1.598 1.071 19.379 to 150 1 L 3.500 0.000 Vel =4.2 L.6 26.000 0.0180 0.00 4.571 0.082 p55 L.6 0.000 1.598 1.285 19.280 to 150 1 L1 R 4.200 0.000 Vel =4.2 TA 26.000 0.0180 0.00 5.485 0.099 p56 TA -38.891 1.598 1.221 19.232 to 150 1 R1 B 8.200 0.000 Vel =2.1 T.5 13.109 0.0051 0.00 9.421 0.048 p71 T.6 -18.276 0.875 49.550 19.057 to 150 1 B1 R 8.200 0.866 Vel =-4.2 D.T.4 -7.943 0.0377 0.00 57.750 2.179 p60 D.T.4 0.000 0.875 3.246 19.232 to 150 2R 1.400 0.000 Vel =-4.2 T.5 -7.943 0.0377 0.00 4.646 0.175 L-3905 Weisberg-Price Residence -Two Head Calculation - (H.34 H.38) Page 10 of 10 Final Calculations - Pipes Wednesday, August 10, 2022 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes Ref. C-Factor Fittings Pe Point Qt Pf/UL +PrLoss. Total Pf p99 T.3 -26.341 1.598 0.990 24.675 to 150 2R 1.000 0.000 Vel = -4.1 T.2 -25.659 0.0176 0.00 1.990 0.035 p52 T.1 -27.653 1.598 14.325 30.493 to 150 1 R1 L 4.200 0.000 Vel =-3.9 L.1 -24.347 0.0160 0.00 18.525 0.296 p48 L.1 0.000 1.598 0.897 34.028 to 150 1 L 3.500 3.465 Vel =-3.9 S.0 -24.347 0.0160 0.00 4.397 0.070 p61 TA -39.109 0.875 6.658 17.925 to 150 1 B1 H 8.000 0.000 Vel = 6.9 H.28 12.891 0.0924 0.00 14.658 1.355 p59 H.28 0.000 0.875 9.108 16.991 to 150 2H 1.000 0.000 Vel = 6.9 H.27 12.891 0.0924 0.00 10.108 0.934 p58 H.27 0.000 0.875 16.309 13.659 to 150 2H 1.000 1.732 Vel = 6.9 H.37 12.891 0.0924 0.00 17.309 1.600 p63 H.37 0.000 0.875 10.426 12.603 to 150 2H 1.000 0.000 Vel = 6.9 H.36 12.891 0.0924 0.00 11.426 1.056 p23 H.36 0.000 0.875 12.401 11.364 to 150 2H 1.000 0.000 Vel = 6.9 H.35 12.891 0.0924 0.00 13.401 1.239 p25 H.35 0.000 0.875 12.322 10.133 to 150 1 R1 H 1.000 0.000 Vel = 6.9 FT.34 12.891 0.0924 0.00 13.322 1.231 p24 FT.34 0.109 0.875 12.560 10.133 to 150 2R 1.000 0.000 Vel = -0.1 FT.38 -0.109 0.0000 0.00 13.560 0.000 hp34 H.34 0.000 0.875 0.000 10.133 to 150 1 H 1 B 11.000 0.000 Vel = 6.9 FT.34 13.000 0.0939 0.00 11.000 0.000 hp38 H.38 0.000 0.875 0.000 10.133 to 150 1 H 1 B 11.000 0.000 Vel = 6.9 FT.38 13.000 0.0939 0.00 11.000 0.000 AREA MAP HOUSE CROSS SECTION 1 & 2 Ax BDILGNGHT. PER HT.a ESTaIcrroN 492.94' 12 48 °"sL492.69' 'tr ''S Reliable Model: RFC43 Residential Sprinkler 5 DFPEaPaTEHT. -14 -- - -- ---- ADLTDFDIrvrvIGaEATaDDM MOST HYDRAULICALLY REMOTE HEAD cappcx#�olid PI � � 12 1 ------ ---- 2 Style: Flat Concealed Pendent ** 1.5 ET HEAD # GPM PRESSURE REO'D AT STREET Nominal K-Factor: 4.3 LeIvICc.EngIne-E-iii� -- --- ----- GwRPUTEHEiGHT g Pressure: -------1 ��' LTTDPPL°°" Max.Working Praa�..��. BEAM®,2+tom ________________________ HEAD # H. H.38 GPM 26 PSI 65 All lb ------------------------ --- DINING - VING -------- ���- �� °� Min. Spacing: 8 't. CITY OF 4ACORTES a iiFtd � a HD SYMBOL MODEL I K FACTOR MAX SPACING - FIRED ARTMENT o � c� � @RFC43 12 SIN RFC43 RA0612 4.3 12X12 ---_---�- 12 @° RFC43-14 SIN-RFC43-RA0612 4.3 14X14 �= "'� REVIEWED FOR ODE COMPLIANCE x ` e ,.-_ APPRO D PLANS T�rsl Perk �k +�nacorLe rr K. Ga snn 5C T e 3 @ RFC43-16 SIN-RFC43-RA0612 4.3 16X16 � Til�I rk. �,7 Prri.?5.711� P.� - 4 z 3 za°FL°oa 475.45' -- 181H'FLOORSYSTEM o BLD-2 2-0650 Regr�rral - - - 9. CEIL NG DROPPEOT'PROM BOL Of BEAM®,tT3,°' SB --_- $ tt___-_1, - ----- SB MNrvaEN. @RFC43 18 SIN RFC43 RA0612 43 18X18 PERMIT#: Airport �,4,,,BFGRWPDECHSLGRE W ---SB 94 OCK RIDGE PKWY _ RFC43-20 SIN-RFC43-RA0612 4.3 20X20 ADDRESS: 3 13 I AIINDRVIMI ID MASTER RFD REIGNS WITH SUPERVISOR L Minimum Required Sprinkler Discharge 131 APPROVED BY: B II Harris p 9 a 9 in m Norminal Temp "K" Sprinkler Max. SUBJECT TO FIELDINSPE ION. APPROVED PLANS SHALL u 2 Model Orifice Size Rating Factor S acing Distance Single Sprinkler Two or More Sprinklers Ace Coriuete Cutting a g P g in T ft. TO Wall Flow Pressure Flow Ea. Pressure Ea. nn ( ) ( ) ( ) NOT BE ALTERED I ROUT AUTHORIZATION. LI (ft.) (9Pm) (Psi) (gPm) (Psi) tam - Mafia°°aria' h, I _ - - 36 ' - -- to tl8'FLOOR SYSTEM �. `� Y� 3 ------ ---------- -- BA=EME.P-EHT 12 x 12 6 12 7.8 12 7.8 - a� E„aM No E:vEaIFYULHEAOEa 14 x 14 7 13 9.1 13 9.1 - ------------------- - FXFRC1,11F ROOM --- MF(:H/STORAC.F ------ -p HEIGHrs wrtH SURERVISOR -- / " I 0 SIN RFC43 1 2 165 4.3 16 x 16 8 13 9.1 13 9.1 I 9 ° 18x18 9 18 17.5 18 17.5 es O le C rar be rr}7 Ag o as7.sa' 20 x 20 10 21 23.8 21 23.8 ! 1h/ sk��rrQn NUMBER OF SPRINKLER HEADS: 44 14 14 SIABON GRADE FL000. Map data 2022 3949 ROCK RIDGE PKWY ANACORTES WA 98221 BUILDING SECTION 1 FILE NAME: L-3905 HOUSE CROSS SECTION #3 WEISBERG- SITE PLAN MxB°"DNTHT PRICE REa HT RE3TWD IGN 492.94' Reliable Model: F1 Res44 SWS Concealed 4B �--- --- oEaAu492.i9' Horizontal Sidewall RESIDENCE &HIDING HT. VICINITY MAP-NO SCALE 5 DPFEaPATEHT Noyle: Conical minal K-Fa for 4 4ed Sidewall �- ®VAULTOF°NNINGGREAT aODM N SHEET NO. Max Working Pressure: 17 I Ij \s ng P 5 ps � 4 w ' 1 `I I '\ \ 2 LDWEaPLATEHEGHT ° ,� - - s =s�a w„.H .®ry �Bo"AwT DPFLDDa � RFDROaM, OFFICE - HD SYMBOL MODEL I K FACTOR MAX SPACING 1 .0 N F1R44A6-12SW F1 RES 44 SWS 4.4 12X12 .;� N � ,` r; �I �'��',11 I 1 V 4 ` Qo F1R44A6-14SW F1 RES 44 SWC 4.4 14X14 --• I OF 4 ' 1 i o F1 R44A6-16SW F1 RES 44 SWC 4.4 16X16 �� \ _\ 12 1,�, 5p 464 �\ \ .\ ` > 13 Model Norminal Temp "K" Sprinkler Max. Minimum Required Sprinkler Discharge O 9 p p Sin le S rinkler Two or More S rinklers V 9' ----- - - - --- --- --- SW Orifice Size Rating Factor S�c�g Distance 9 P P Iry PUTE fir LOT 7 l „r r \ ��• \_ - OFFICE/BED2 _ MASTER RATH TES DEa 35'. 318 \ I"ieIGNTs wITNsuREav soa a`�'�6 e - -------- --- - - F1R44A6 Flow Prsre Flow Ea. Pressure Ea. 0 81 ass'as, � � _ � (in) F) ft. T( Wall ( m (psi) m si � r' �,�� �' 8 �v a Top of Deflector 10 (� �+ �� 459 y, soy �� �� m o o a PLAN AREAS to Ceilin Z ,095 SF m asa: s� 2 m Inch mm q 6 12 x 12 6 13 8.7 13 8.7 � � „�� �� �� �� MAIN FLOOR ( ) aso yo ..� oo j UPPERFLOOR 4 to 6 14 x 14 7 14 10.2 14 10.2 90 3/8" 155 4.4 _ 440 „ a IN FLOoa asa' 16 x 16 8 17 15.0 17 15.0 O 0 141I8'FLOOR SYSTEM BASEMENT (1DD t0 152) _ ` Q i 11 eASELtENTPUTE HT TOTALLIVINGA _ } r (0 465 9 rvoTE.vEwFvnuR�,DER STORAGE/UTILITY 0) 1 - MEDIA RDOM I(�F CiT BED ---- HEIGHTS WITH 3uPERV SOR IF 0 9 to a GARAGE NUMBER OF SPRINKLER HEADS: 1 � VG.ORG.GRADE=457.94�\ c /r i m "cam 457.94' ENTRY&REAR PORCH N 71 1 445 % OPEN BALCONY GARAGE v h� /,. � It r / ,, *f�� � - � �� COVERED BALCONY Z a� r FF-464' '` 14 \ 14 OPEN DECK aAseMErvrFLooR 52.73' BUILDINGGRPDE FLOOR O Q FOOTPRINT 2519 SF \\./i ;,� I LOT SIZE=10.D95BFill � I �� COVERED DECK ry I� Iz4.95%LOT coV1 // �,/ r' ,.1451 1 s`� LL_ V N , "-� / 4`_ asa 457 ass >'''452; r `/ Reliable Model: F3QR56 Dry Horizontal Sidewall with Standard Escutcheon (SIN R5714) M III_ co E / Ceiling U 00M Q 459as4� �� Style: Pendent Q X W a6a 456' HOUSE CROSS SECTION #4 y o 46 I � I Nominal K-Factor: 5.6 - 11 200 W 462'461' iaTEMATEawL Max.Working Pressure: 175 psi Q 468' 465' vASSE rye �463 _-_ l R " ry Chi g /I; I��y� ^�� u3TRAT 011 I N O / VI STAN Ld- o� / 1 g / f y - - ,, .1v`� esr4S2.6492 I- O. � G t t acv x�r rso .94 � Q cz ) -WA v cn a Q a LU r r ,/ / a76 �S -Q„ ) WATER CONNECTION 5 0w"D ofou„„c,G„FnTxoox 1B -MID " ncxanPRQ j I WED STUB •" HEEL I � ��•qC / 6 SS 8 �.."..-..�..w.a.. � -Ra81 .�. -14"B ICI - u O / LLYING- KLSCHEN BATH f)FFCF t -R3a Ill J i PLAN AREAS : $ z R T a N J -RJa MAIN FLOOR 1,353 SO. g= # SB 8/a" A y a - ,1 UPPER FLOOR 1,573 SO. ■ TO MAT BASEMENT 1,083 SQ. M iv M cz �/ wrcuaroaeR , TOTAL LIVING AREA' 4.009 Sa. --- - B-T8 E d � STORAGE/UTILITY 181 SQ. "uNG°A0PED3 aiON B - w+"Fue�� t L�.I \ I / ''. /PROPOSED CONCRETE WASHOUT AREA ,z„�e Foaavocceuovt: C H OR MAY USE SHARED CONCRETE WASHOUT GARAGE 725 SO. GARAGE --NMARTRR RRn MARTFR Ae PRIM V 1 LOCATED OFFSITE IN ROCK RIDGE DEVELOPMENT ENTRY&REAR PORCH 195 SO. m e B 'o © _V MBE H/ 1 S F F�M OPEN BALCONY 331SQ. - -SMO Technical Data UU COVERED BALCONY 224S0. -PRIM 7❑ -XME Nominal K-Factor 56 gp n/psi Z Z OPEN DECK 122 SQ. WN 0 O Sprinkler Lls ting or Approval Deflector to Cel Cirg Distance Maximum Work ng Pres s.nre ° ,.uaoaasrareM """a COVERED DECK 1s4 SOT 3B ____ B❑ _TI F3QR56 Dry cUlus NYC See Note Below 250 psi 17.2 bar WEISBERG-PRICE RESIDENCE -- Ba�-- ----- ----------= - 0 -2Xa W Q _ _ Pendent FM See Note Below 175 psi 12 bar R-21 I �e �H 9❑ -I/r F3QR56 Dry cUlus, NYC 4" to 6" 250 psi (17.2 bar) W Q W 3949 ROCK RIDGE PKWY ANACORTES, WA 98221 ���7.94 TSIDIYP" Horizontal Sidewall 4" to 12" 175 psi 12 bar) 0 (�• 10 -VERI FM See Note Below 175 psi 12 bar PARCEL# P134318 INS'L F3QR56 Dry Upright culus See Note Below 175 psi (12 bar) 14 '0 NA LU '0 -------sM"eHd,AOEFrooB N>sENDrtFLooRasz.7a 11 B)-EN NUMBER OF SPRINKLER HEADS: 1 W ALAS 12 BI-ME ALL Y = 13 14"c LU INSTU.11 CIO TO SPRINKLERS DAB-E.SYBOX 14 R-10 Cn I Q W (ALSO TOILET SUPPLY) B4 co Q ELECTRONIC PRESSURISATION SYSTEM BUI - � 65 PSI-32 GPM. WATER SUPPLY THIS SYSTEM UTILIZES A 1.25" SERVICE LINE & DAB E.SYBOX U) 2 N O V PEXUj SUPPLY BOOSTER PUMP CAPABLE OF PROVIDING 26 GPM @ 65 PSI. Q U � V 0 H 9 HOUSE CROSS SECTION #5 POMP 0 0 0 STATIC PRESSURE 65.000 1. SYSTEM TYPE: MULTI-PURPOSE FIRE PROTECTION SYSTEM. Q 0 EXTERIOR BELL Uj ax xT VFSTn,cno„49294 CPVC 1.5"X1"TEES -°'gag RESIDUAL PRESSURE 60.000 00 WATER --- --- - ,- --- --- - - --- --------------- , ------------ ° --- --- --- ------ ® �,oFa„„ „�,„ , 2. PIPE: RAUPEX NON-BARRIER- U.L. LISTED FOR MULTI-PURPOSE Z N PRESSURE ,, AVAILABLE FLOW (GPM) 32.000 FIRE PROTECTION SYSTEM. U) In GAUGE " ��„ � TOTAL PRESSURE REQUIRED 39.567 >_ Dcclnc &tT�HHE6LU II�IMr:-,, „ " �.� _ . . TOTAL REQUIRED FLOW (GPM) 26.000 WET PIPE FIRE SPRINKLERS SYSTEM. 00 3/4" LISTED AND APPROVED FOR ______________ ,a__ ,o _________ __ s Tnvaacn s TEST V WATFRPRnnF ncrx b i Z DRAIN p' SAFETY MARGIN (PSI) 22.028WATER I FLOW a 4. FITTINGS: EVERLOC- U.L. LISTED FOR MULTI-PURPOSE SWITCH SAFETY MARGIN GPM 6.000 U) Q 3/a" " (GPM) FIRE PROTECTION SYSTEM. < PEX 2 ^^I" wuwawuTux ,e+A•NoaRss,eM z„o aoa+475.a5' w,aF wa --_ __Rcn-- z ____ ____BATH___ -o _ __ al lungs o __ u`(A F«r°oou=c,00E IJ� _9 -._______'"""'"'"""°°' allow ehbat from ef ndmoved DRAIN 11OVAC 1"TALON -- R 9 SUPPLY -- - -- �Po;,ed 5. FITTINGS: SPEARS CPVC- U.L. LISTED FOR NFPA 13, 13R& 13D SYSTEMS into the I� CPVC 1.5" B a spaceand keepthe pipe a r CHECK = warm. II VALVE e w $ 1"PEX 1"PEX s "". DOMESTIC SB LL! SUPPLY „ -----ExERorcF------ -' H,e'flooeasreM s.swFmfwTe xT. m- oE:�Rn „ MlJlsi �l'OMTAT J J MAIN � Q -------- 9--------mBole----- Rau - 0 /� ,B ----�a UPPE ; 1_ Z �Ir^ 1.5"BALL VALVE 451.94' BASE � Z VJ MAIN SHUT OFF ExTEaloa wALLLTBATT /�a� 1w� �^ TOLco cPvc O m+° Leo„ Fa�R STO RAPPED AIR SPACE / � Wis i �I �r Rimer M� 1"PEX l/ ❑ _, __ R.00R 4sz.T3 GA INSULATION TENTED 1 l� �ISw A Level N HANGER allOVER PIPING ri ��L �C 11 yr }� UU LEV ` CPVC 1.5"X 1"TEESwoo- ENTR TENTING i X-Fire 1 - O TEST ORIFAc OPEN XF P co E COVE XIrIRE'�19PN i J W co HTOLCOANGS CPVC ' a I I I HANGER OPEN � . COVE i * U ■ i II!!i1 � Z � LL o FIRE SPRINKLER RISER/ DAB E.SYBOX BOOSTER PUMP UPPER FLOOR MANIFOLD IN WALL EXAMPLE ■rwsi■■>•■■ss■sww■ass■■sassume � _ Uj N c� 0 HANGERS AND SUPPORT- CPVC FLAMEGUARD PIPE HANGERS AND SUPPORT- PEX PIPE GENERAL NOTES CONTRACTOR OWNER STANDARD SYMBOL KEY HYDRAULIC CALCULATION SYMBOL KEY � E 00 M L PIPE SIZE MAXIMUM SUPPORT s THE HANGAR/SUPPORT REQUIREMENTS COMPARABLE TO ONN FED BY LOCAL PLUMBING CODES" NOMINAL TUBING DIAMETER (in.) SPACING (in.) 1" FLAMEGUARD (CPVC) PIPE SPRINKLER HEAD WITH HEAD S.0 SOURCE Dia INSIDE DIAMETER OF PIPE d O 1. THESE HYDRAULIC CALCULATIONS AND SYSTEMS (INCHES) SPACING (FEET) THE HANGAR/SUPPORT REQUIREMENTS MUST ASLO BE FOLLOWED ON NFPA I3D SYSTEMS. ARE DESIGNED IN COMPLIANCE WITH NFPA 13D STRANDBERG CONSTRUCTION INC WEISBERG-PRICE H9 o NUMBER, SPRINKLER TYPE = TOLCO CPVC HANGER 3/8",1/2",3/4",1" 32" TUBE TALON 2. ALL INTERIOR PIPING TO BE"REHAU"PIPE UNLESS 1.5" FLAMEGUARD (CPVC) PIPE H.1 HEAD NUMBER C-Factor INSIDE OF PIPE SMOOTHNESS M 3/4" 5-1/2 FT OTHERWISE NOTED. P.O. BOX 319 3949 ROCK RIDGE PKWY RFC43-16 NUMBER&COVERAGE r N O X 1.HORIZONTAL RUNS MUST BE BRACED SO THAT THE STRESS S.RISERS MUST BE SUPPORTED BY PIPE CLAMPS 1.PLASTIC HANGERS AND STRAPS ARE RECOMMENDED,BUT 3 PER NFPA SPACING REFER TJO SPACINGSPRINKLERS CHARTIS aOR DOMESTIC PIPING R.30.A RISER NUMBER FT FLOWING TEE � d O M X 1" 6 FT LOADS WILL NOT BE PLACED ON A FITTING OR A JOINT. OR BY HANGERS LOCATED ON THE HORIZONTAL14, METAL SUPPORTS WHICH ARE DESIGNED FOR USE WITH ANACO RTES WA 98221 ANACORTES WA 98221 m O L,L SUPPORT SPACING IS SHOWN IN THE FOLLOWING TABLE. CONNECTION CLOSE TO THE RISER.ONLY LISTED PLASTIC TUBING CAN BE USED. MAXIMUM SPACING BETWEEN SPRINKLERS AND 1 T O HANGERS AND CLAMPS CAN BE USED.VERTICAL FROM WALLS. PHONE: 360-293-7431 3/4" REHAU PEX PIPE I T.30 TEE 1B 1 BRANCH OFATEE 1-1/4" 6-1/2 FT 2.WHEN A SPRINKLER HEAD ACITIVATES,A SIGNIFICANT LINES MUST BE SUPPORTED AT INTERVALS TO 2.VERTICAL TUBING SHALL BE SUPPORTED AT EVERY FLOOR 4. THE ROUTING OF THE TUBING SHOWN ON THIS REACTIVE FORCE CAN BE EXERTED ON THE PIPE.WITH AVOID PLACING EXCESSIVE LOAD ON A FITTING (8-FEET TO 10-FEET HEIGHT)AND AT THE MID-FLOOR GUIDE DRAWING IS INTENDED TO BE SCHEMATIC. THIS EMAIL: 1" REHAU PEX PIPE HORN STROBE P.1 PIPE NUMBER 1R 1 RUN OF ATEE 1-1/2" 7 FT A PENDET HEAD,THIS REACTIVE FORCE CAN CAUSE THE AT THE LOWER END.THIS CAN BE DONE BY USING BETWEEN FLOORS. DRAWING SHOWS SUGGESTED ROUTING ONLY. PIPE TO LIFT VERTICALLY IF IT IS NOT SECURED PROPERLY, RISER CLAMPS OR DOUBLE-BOLT PIPE CLAMPS o ALTERNATE ROUTING MAY BE USED,SO LONG AS Aimee@strandbergconstruction.com LA 90 DEGREE ELBOW PT PSI TOTAL 1H 1 SPRINKLER HEAD .. ESPECIALLY IF THE SPRINKLER DROP IS FROM SMALL LISTED FOR THIS SERVICE. 3.WHEN PENETRATING METAL STUDS,UTILIZE A PROPERLY-DESIGNED THE SPRINKLERS ARE CONNECTED IN THE 2" 8 FT DIAMETER PIPE.THE PIPE MUST BE BRACED AGAINST THE BUSHING OR SLEEVING MATERIAL ON ALL PENETRATIONS TO PROTECT ® ARRANGEMENT SHOWN. ' VERTICAL LIFT-UP WITH THE CLOSEST HANGER. 6.THE RISER SHALL BE SUPPORTED VERTICALLY TUBING. 5. ALL PIPING TO BE SUPPORTED ACCORDING TO D.T DOMESTIC TEE PF PIPE FRICTION 1L 90 DEGREE ELBOW 2-1/2" 9 FT WITHIN 2 FEET OF THE CEILING OR BOTTOM ® NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. 3.ALL INTERIOR PIPING TO BE 1.5"SPEARS CPVC. OF THE JOIST. 4.PIPING LAID ON OPEN JOISTS OR RAFTERS SHALL BE SUPPORTED IN 6. THE PIPING ARRANGEMENT AND HYDRAULIC T.30 NODE (TEE) NUMBER PE PSI ELEVATION MN F MANIFOLD 1 3" 10 FT SCHEDULE 80 FITTINGS AND PIPE. A MANNER THAT PREVENTS LATERAL MOVEMENT. ® CALCULATIONS ARE PROPRIETARY PROPERTY RISER FLOOR CONNECTER 7.MAINTAIN VERTICAL PIPING IN A STRAIGHT OF XFIRE AND XFIRE RESERVES THE EXCLUSIVE RIGHTS 4.SPRINKLER RISER DIAMETER TO BE 1.5" ALIGNMENT WITH SUPPORTS AT EACH FLOOR 5.SPRINKLER PIPING SHALL BE SUPPORTED IN A MANNER TO PREVENT THE TO THEM. UNAUTHORIZED REPRODUCTION OR USE IS P11 PIPE NUMBER R.30.A AND RISER NUMBER QA GPM L.2 90 DEGREE ELBOW LEVEL,OR AT 10 FEET INTERVALS. MOVEMENT OF PIPING UPON SPRINKLER OPERATION. FORBIDDEN. QT GPM QUANITY D.T DOMESTIC TEE r— — —1 r■■w■■■■■■■■rtarrrswl�� WARM M T M*rAT§ CIt1r'iMCATE Of COMMrsMM wMa ars" s r■rs Charlie Johnathan Rimer • 4425-N22-A Leven ■ X-Fim e I XFIRE"961 PN 1 I I FILE NAME: L-3905qg o 1 r LOWER LEVELWALLS WEISB ERG- PRICE L — J L— - STAIR FRAMING PER ARCH AND CODE MIN. I ° ` I RESIDENCE 2_ <3�A9 I I SHEET NO. 67'�" 2e0 13'-7" 21'-3" r 28'-2" 10'-9" 8'-8" 15'-5" I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 7 6 P R E T. A L L - - - - - - - - - - - - - - - - - - - - - - - - - - I 20F4 r 1 1/2"TOILET LINE I [V I O STORAGE/MECH. EDSB Box 10"CEILING BATH FC43 H14 0 1 0 17HD 0 PUMP TER 10"CEILI G GUEST BDRM "' V z V 10"CEILING LO P 3L.3 — R.1. z N b � I I I L.1 I P v 0 0 4 2 I • — — — 4 U Dill 0) A 10 8 1.5"SPEARS CPVC PIPE I • W A 10 m e I FIRE SPRINKLER S.0 r RISER/MANIFOLD I H.6 { T.1 L.2 I I H.7 €� 04 1"REHAU PEX PIPE 0 RFC43-18 RFC43-16 � 00 WATER SERVICE ( " Q o Z O x 0 Q ~ fn 1. 1.25"WATER SERVICE LINE(80FT).3/4 WATER METER. I I RFC43-12 FC43-12no x q U M 2. DAB E.SYBOX BOOSTER PUMP.65 PSI 32GPM. 3. PUMP LOCATED IN MECH STORAGE. I H/ LL 3 H. O a� @� P Cq O W _o W N d I I-� ., II ■ N - - U mM � co E _-3 10 7/1 4'-1 1/8I- - z 0 0 w I 13 I zQz — P 2 — O H O Z 2 I z U cnaQaw I 17HD C) co M W it H.10 H.9 c N a r Ld RFC43-16 RFC43-16 a �co N J Ll I I H.243-16 Q j A Z � M M MEDIA ROOM = S; I I 10"CEILING N 5 I I I I � 5' � wA e N A10 LU A10 — + — — — — — — — � � DECK 13 - LU v� Z W a I I EXERCISE RM 8'-0" X 17'-5" V O_ O_ 10"CEILING \ O 139 SD FT Ln w L 0 G o PAVER DECKING > > L — — — — — — RFC43-16 RFC43-16 o W Q r' W L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — - - - - � m Q IrsII I i _ a z � 17HD wQ wa cnd..,L„configura-ion - .,��`IX/1 13 77P W Q //// II I READING NOOK — -- — — — — — — — — ght stud each and{plate to plate-) \\�\\�\\�\\ 10"CEILING -._P weT MIR � 0 stjds each end(plate toplate) 1/2" SHEETROCK II I _ 4 I 8'-0" I W VLU m UL Trimmer,each end I{®g Stnd,each \\/\\/\\/\ • I I min.,use (f blank use defadt end ifbtaukuse /\\\�//i\\�j/i\ce CONCRETE WALL STAIR Qw � O H.22RFC —1 labove.) defailtaboce.j 4xo R-21 INSULATION — LL Iq Z N 1"REHAU PEX PIPE ~ 0) 00 U x9ylula11 - \��/\��/\ 2 X 4 WALL @ 6 FROM CONCRETE II I RFH. CLOSET \/\/\ I RFC 43-16 9-4 I � � 12glulan 2 2 BUILT OUT ONLY IN FINISHED AREAS II I m \\\\ \\ V UP z s Or_6rr1/2" WEDGE ANCHOR 48" O-C.cs harein.Default LSL is 1.5E.2.300 psi.min=b. /\\//\\//\ I I Q tL n..2 studs below. / iii\ 2 X BORATE TREATED PLATE • e p rla I e — -W67 3060 CASE-W66 3060 FIX CASE-W65 3060 CAS — — — — — — — — � — — — — — L eaz or R1ti44. \�I/\�// I r -9" 3'-0"- ��T-0" 14'_3' /\/, . I L f 1-2„ ate" o,�„ or ULU wet-set beam seat. 8'6" 12'-1 112" 13'-8 1/2" � r similar. Bear cn top.2 H3AW TYPICAL FURRED OUT I I I I � � � LU w 5herem. Uj Co 'blank WALL IN BASEMENT pQ �.,use use defauh,above) Notes � SCALE: 3/4" = 1' 2 3 zcoA9— HWPF to 388 A N HWPto386 � I II I � 1� � 00 x8 nailer on top,connected with 2,SOS 1'4 x 3 L 21"up TYPICAL HEADER FRAMING I I I Q 00 ber_Connect w/2.S/tf'x 4"lags through bottom flange to - _-_ -^r I—J 1 1 1 BASEMENT FLOOR PLAN 0 `` z iL o co � E 00Lo U � _ _ O 04 LO O M M OT_ m M ... LL J � *■�■■■■■■■■■■■■■■■■■w■■■■mow■� 1 a WAS TOM ATAT# cawrtGA9 I�i A TN PM o����11rit�i • 14'-2 1l2" V 13'-9" it �� imer 73P T3P 73P MAIN LEVEL WALLS ful Q�Qr I INTERIOR BEARING WALLS ARE INDICATED WITH RED DASHED LINE. X-Fire T'�_ 84 SF SLAB 2 - STAIR FRAMING PER ARCH AND CODE MIN. 3� XFIRE"961PN A9 A9 i 27'-6" 18'-9"- 14'-0 1/2" 7'-2 1/2" 3'-6" 21'6 1/2" 3'-2" 3'-3" 1'-9"��3'-0" 5'-0" s�3-0" T-1" 3'-0"��2'-11 1/2"-�{�3'-0" 10'-3" FILE NAME: 7cP W063056 CA W07 5056 FIX CASE W083056 CASE W09 3056 CASE W103010 PIC OBSC. L-3905 li@1os° W f9 15F WEISBERG- N PRICE a ) MASTER SHOWER mi M.CLOSET RESIDENCE MASTER BDRM I a� 6'-S"x4'-s" e� 1o"cElulvG CO U I 10"CEILING L.4 35 SO FT 0 4 iv o I R.2.A l ss1/2 " SHEET NO. ILDill CURELESS 390 tq 4 ° RFC43-16 I P 9P 8 R.3.B M iiiill H.43 I�o Y A CDH.41 I �� RFC43-18 RFC43 16 § 4 A 0 3 RFC43-16 1 � RFC43-20 H.19 H.20 th — — 3 OF 4 - H.18Prza A10 M.BATH D.T.2 — N 1"REHAU PEX PIPE 10"CEILING U O os GARAGE 1 1 0 10"CEILING 74P 1 z P 8 i Z 15F 0 N � 1 4 I P 3 1/2"TOILET LINE u? � W16X50(16.3"X 7")STEEL FLOOR BEAM — — — — ?— — — — — — — — — — — — — — — — — — — — — V FULL HT. , ,1 PANTRY 1 3 O L) UILT IN BENCH CABINET RFC43-16 RFC43-16 4'�" N ) H.17 H.16 VERED DECK N c~n N P 8 P 7 H.14 00 43-12 474,SQ FT 0 Q r ,- - - - - - - - - � r-- - - - - - - - � U N I RFC43-16 I I RFC43716 N m N v H.40 H.42 MUD RM �w x -- W w c E o m I I I I 10"CEILING P 6 RFC4 1 LL ° 0 15FF .- U m M CO M E o O I 1"REHAU PEX PIPE H.15 P 1 P 6 tin ZOO W Q IL I I 9 I C43-12 13 5` H amUzJ P9 H.11 —7 A10 O � Qz = � A 0 f RFC 3-12 0 in o VERIFY DRYER VENT H.131 L) OPEN DECK T v co la Q a W BATH #2 BDRM #2/OFFICE -a 1 10"CEILING 10"CEILING ° 3'-$ X 17-4" - 14 63 SQ FT 1eo AUNDRY 0" a P RFC43-16 PAVER DECKING A O -w — 10"CEILING 1/2"TOILET LINE H.12 N J 070 004 9080 — 003-9080 o Q 2 1 3'-0 a'3 -0" — 2-4- 0 - - - 9'0" - - 13'0 D.T.3 P 5 0 A V �` \ � W W � � W � I..I N 6'-0" 27'-11 112" 8'-0 1/2" r° 0 '� 00 N�-I v N HORN STR J J 1"REHAU PEX PIPE 15FF Z W 17HD 0 U �= I ENTRY PO R H LU a a a. — P — — — —TT 0'-5 " 73P 13 z z 8'-5" X 11'-11' R R R 1'-1 1/2" O O I I o 100 SQ FT I � R 12'-1 r' 4'-0112"��3'-6" Cn �g H.45 > H > O W� 10'CEILING C43-12 F1 R44A6- 6 W Q W M DRIVEWAY AREA UP I �, SLAB FLOORo H 23 DNM LU 14" o TO PROPERTY LINE TO 1 ,006 S.F. tj I STAIR A9 °' B b �' Y 0 5 112"X 12"GLB EXPOSED li d 0 -TOP @ 121 1/8" 4„ , LU B 17HD ,'-0 OPEN TO ABOVE P ll�kco&) 0Cn 66 a U_ � ZZ V // 1 � w 2C a < 13 20H@114" LU - Y 2 ON INNER O W193076 PIC W1830711 PIC STRUCTURAL WALL Q � V 13 RETAINING REDI-ROCK WALL 2'-9" 3'-0 12'-01/2" 3'-0" 3'-0" v ❑ 1'-0" 1'-41/2" 0'-11" 1'-41/2" r W Q N T6" 1T-91/2" 9'8" 7'-61/2" O z O V Jo© I LU 07 MQa� 35'-0" 36-0" `y 2 3� 00 1 CALL Z Ioo A9 A9 , _ 7 Zo omin"L"tor>figura'ion TYPICAL HEADER FRAMING Boa Itend. O eight stud each md(plate to plate) WINDOW W/ 6" POST HEADER LESS THAN 5' a N u ht ctids each end(Plate to plate) pnsh Ii Trimmer.each end King Stud,each Default material is Jag Fir No 2 or bette-- ' W 2 min.,use (ifbiank use defaalt end Ublankuse Default bottom connection on plate:2.A34 with TECO or screws or 4,16d-ace rails. W W above.) defzuh above.; Deiauft bottom connection on beam:2.A34 vntt TILCJ or screws.or PCZ. O J J Default bottom connection on concrete:PB.or AB.of A3U,or ABW,cr CBSC U 4x6 Callour :ilia..use Alt 1 Mon..,use Alt 2 uuu..ose Cooaector'ifolari \otes Z Cn HEADER LESS THAN 5' use default,above) Q Sx9 gluloct 2 70P 2-2x4 4>:4 2x6 � N 5x12 glulam 2 2 M 71P 3-N4 2-2x6 4:6 (1)KING STUD FROM TOP PLATE TO 72P 3-2x6 6>:6 4-2x= LU � � — V� 7�tS (1)TRIMMER BOTTOM PLATE 73P 6e6 PT00 W (2)KING STUDS (1)TRIMMER 14P 5x'U - J LLI MAIN FLOOR PLAN Z Uj .219 3: coT 2E 00Ln I; d s T O _ _ 04 O LO O M M OT_ m M ... LL J � WAS TOM OrATI ■ 4tRnNGAT§Or C_ . R 11rGV ■ I!!1� 'IMOTlCTi0111 Sploom 1.o ■ ■ Chwile Johrsathan Rimer 4425-N22-A Levei I i ■ X-Fire XFIRE'*981 INN igal ■ �■www,ssw,s■■wwi�www■mow■�»�wwwN>wl+wi 1 FILE NAME: 9 A 67,_6,. L-3905 27'-11 11T �I 39'-6 112" UPPER LEVEL WALLS WEISBERG- - INTERIOR BEARING WALLS ARE INDICATED WITH RED DASHED LINE. PRICE 13 - STAIR FRAMING PER ARCH AND CODE MIN. RESIDENCE 2 - FIREPLACEAND CHIMNEY FRAMING PERARCH AND CODE MIN. 3 14'-0" A9 SHEET NO. CID35'-5" N-8" 2'-4 112" 12'-0 112" 1'-61/2" 12'-0" O'-11112" 0'-5" 4*0 0'6 a 6" a s" 0'-6^ 0'-7^�101� 310'6" 0's" 0'6" 0's" 1'-0" IN 1\ v W33 3830 PIC W34 3830 PIC W35 3830 PIC 3830 PIC W37 3830 PIC W41 3820 PIC1\ 1\ W42 3820 PIC W43 3820 PIC 2 6" 3'8" 3'-0" IN 1\ 3'6 3'-0" W38-12080 4 PANEL ACCORD AN PATIO DOOR' W 9 3866 PIC W40 3866 PIC W44 2616 PIC W45 3060 ASE W46 3660 FIX CASE W47 3060 CASE 4 OF 4 I 20H@144" � 20H@144" � 20H@96" - N V V P24 ! 4 SHOWER T.4 OFFICE #1 N 0 OP N BALCONY a a RFC43-16 _ _ 16SQFT T. 10"CEILING co 13 1 '-11" X 1 1'-8" k 2� H.38 i 0 O 1163 SQ FT &) m'' 11 1 LIVING RM I I I I TILE SHOWER o I OK WITH CURB 4 o V V VAULTED CEILING 1.5/12 PITCH 24x4a 24x4e o RHSKYLIGHT SKYLIGHT I 4 Z H .4.B P o P 7 Z t}n _O I I I RFC43-1 3 I RFC43-16 I I - - - _ 6 1 1 RF 3-1 � 0 4 F 4 - + H.34 H.35 r 1.36 H.37 H.28 �� A10 I w I RFC4 16 1/2"TOILET LINE Q. HF2C9 3-20 LL - A10 L_ I PAVER DECK BAT o - 9 - � N � o � � — — 10"CEILI � •" � r � rl I w � I w I I I w I w I ® Z 0) i �4 o MOST DEMAND HEADS S I S I ® `� O Q �' c� O'5112" `gym x� IX83 9Xm I b V 1n 112' 31 B 5 ur x 12"GLB EXPOSED m H.34, H.38 I m D I m n I MIS w w TOP@121va — — — 4 p0 �� I �� I �� P 8 P 9 Pi a o REQUIRED FLOW 26 GP t o O I o o- v o w O U) N d (/, - a- - - I I N oy 10 1 1 1 �O I I �o Illx o O `,`, w o m q z 72P 13'-6 112" 72 2-0 P 4 x J x I x I x 11 o- g M I_ co U m >C � MQ w -11a J �o o law I ° ¢ o Q N t' !v O w IfT o wy EL I �(L I u� Lu Ja a KITCHE T _ O O z� o o I -o 0 1 H Q m U Z 0 00 W_ o a 17 F VAULTED CEILING 1.5/12 PITCH Z io> o > � I zo I o I o I IIa I I � . O H O Q 2 O o Iv I I ° RF 3-16 Z Ma I� I H.27 b U fnaQaw = o COVERED DECK I I I IL _ _ _ _ _ _ _ _ _� I CLOSET � Ncn z LL o u z � w 239 SQ FT I I I I I I I I - N W r z a LU > < 10'CEILING 00 a Iv 0 LL PAVER DECK ° W w [� Q I�"I N J J 72P Z m z z 21 1-16 P 1 RFC43-16 RFC43-16 I RFC43-16 RFC4� 16cn A Z co M 33BLLs t2"X12"GLB EXPOSED � LL LO cK��� l H.30 I I H.31 I I H.32 I I H.33 g 4 w N _ -TOP @ 121 1 r8 o P o in c� ` 00 00 5 — — BBQ — — I T.6 I I 1"REHAU PEX PIPE — C 's 11 +II -Lu b A 110 v� z w A10 I I I I I I I I I FC 3-1 RFC43-20 LU Z Z 1014" H.26 H.46 x 0 O O F QR56 Dr Horizont I Si ewall P 2 DINING RM P 8 �- § Lo v_) O y o P S T.8 VAULTED CEILING 1.5/12 PITCH I M N w 31 B 5 1t2"X 12"GL EXPOSED H 44 _ N Z \w Q \w 73P -TOP @ 21 1/8 T.7 _ — _ _ rr `n / ~ (�• / I I F1; ACCESS [9 Q I I I I WETSAR P 7 I I Lu Lu _ VAULTED CEILING BEDROOM #1 4 O 10"CEILING r 9'CEILING TRANSITION g `�' a JO W25 3816 PIC W24 3816 PIC W23 3816 PICLL W28 3856 CASE127 3856 FIX CAS W26 3856 CASE PANTRY '0'^LLJ Q 10"CEILING V o�" 0'-0 �4 w Z 1'_7" 3.�. IN 3'4r 3'-8" a — — — — — — — — — — — fn b o OPEN TO BELOW N w N a J = a I a LUlY Y w ih � U � 36'-0" N 7 p U � DN I 0 4 4 2 Q V 1 1 o RFC43- 1"REHAU PEX PIPE F 4I 6 :- H ( Z o V A9 H.24 cn M Q a� CN Lu 20H@96" 20H@96" � 0 17 / W58 3060 PIC '^ W57 3076 PIC W56 3076 PICZN am V 3.4r 12'-01r2" " Y-o" 3-0" ' w Div 1'-5 1/2" V-41/2 0-11 1-0 1/2" W 17'4" 94r 1'fi 1/2" U) W O J LU 32'-6" J a 2_ a Z coU A9 A93 � � � — Ulm Lu M = � 04 N tom in"L"corfigura:ion TYPICAL HEADER FRAMING 00 00 h and. ca J LJ.I w UPPER FLOOR PLAN (f) `` zuj � � o >' � coll? 2E 00Lo u � Y o _ _ O Lo O cM t13 OT_ m m ... LL A- J �