Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2022-0592 2214 Lake Park Drive
City of Anacortes Invoice/Permit#: BLD-2022-0592 904 6th Street Applied date: 07/26/2022 P.O.Box 547 Issue date: 07/26/2022 07 Anacortes, WA 98221-0547 Expire date: 01/22/2024 r"9CtJ"���`� (360) 293-1901 Job Address: 2214 LAKE PARK DR Permit Type: Mechanical Permit ANACORTES WA 98221-8733 Project: APN: P99088 Remarks: Install new gas fireplace insert. Owner: MITCHEL&JENNIFER ANDERSON Contractor: BARRON HEATING&A C Address: 2214 LAKE PARK DR Address: 5100 PACIFIC HWY ANACORTES WA 98221-8733 FERNDALE WA 98248-9080 Phone: (360) 391-4237 Phone: (360)676-1131 License#: General Information: Fees: #of Gas Fireplace 1 Mechanical Permit Fees 34.15 Total Calculated: 34.15 Deposits/Receipts: 0.00 Total Due: 34.15 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced wi 0 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and ex a ' ed this a plication and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY Gl � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 61h Street, Anacortes WA 98821 4co � Phone: (360) 293-1901 PLUMBING & MECHANICAL PERMIT APPLICATION Please complete all applicable information and submit to buildingpermit@cityofanacortes.org PROPERTY INFORMATION PROJECT ADDRESS ASSESSORS PARCEL NUMBER 2214 LAKE PARK DRIVE P99088 PROJECT VALUATION 8 RESIDENTIAL ❑ COMMERCIAL $3500 PROPERTY OWNER OWNER PHONE JENNIFER AND MITCHEL ANDERSON 360-391-4237 OWNER ADDRESS OWNER EMAIL APPLICANT INFORMATION ❑ PROPERTY OWNER ❑ CONTRACTOR 0 OTHER: APPLICANT NAME PHONE DORI VAIL 360-676-1131 EXT 196 ADDRESS EMAIL 5100 PACIFIC HWY, FERNDALE , WA 98248 DORIV@BARRONHEATING.COM CONTRACTOR INFORMATION NAME PHONE BRYANT MATTSON 360-676-1131 CONTRACTOR'S BUSINESS LICENSES* STATE LICENSE# EXPIRATION *All Contractors & Subcontractors must have a valid BARROHA179D7 10/23/2022 City of Anacortes business license prior to doing work CITY LICENSE# EXPIRATION in the City. ADDRESS(STREET,CITY,STATE,ZIP) EMAIL 5100 PACIFIC HWY, FERNDALE, WA 98248 DORIV@BARRONHEATING.COM PROJECT INFORMATION DESCRIPTION OF PROPOSED WORK: New gas insert installation IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? ❑ YES 0 NO If YES,provide the permit/application number: Plumbing/Mechanical Permit Application Updated December 2021 Page 1 of 3 MECHANICAL APPLIANCE/EQUIPMENT INFORMATION (NEW AND RELOCATED) EQUIPMENT TYPE Indicate the number of fixtures for each equipment type TOTAL GAS ELECTRIC OTHER-Please specify COMMENT Furnace Wall Heater Water Heater Heat Pump Air Conditioner/Handler Radiant/Hydronic Heating Exhaust Fans Range Hood Fireplace Clothes Dryer& Duct Stove/Range/Oven Refrigeration Unit Gas Piping/Outlet(s) Boiler BTUs: Other 1 gas insert TOTAL MECHANICAL OUTLETS PLUMBING FIXTURES FIXTURE TYPE(NEW AND RELOCATED) TOTAL FIXTURE TYPE(NEW AND RELOCATED) TOTAL Toilets Refrigerator water supply Kitchen Sink Pressure Reduction Valve/Regulator Utility Sink Water Service Line Tub Water Piping Hand Sink Washing Machine Shower Electric Water Heater:Tank-less? Yes ❑ No ❑ Dishwasher Backflow Prevention Device Urinal Hose Bib Floor Drain/Floor Sink Drinking Fountain Hydronic Heat in: ❑Floor ❑Wall Grease Interceptor Other-please specify: TOTAL PLUMBING FIXTURES Plumbing/Mechanical Permit Application Updated December 2021 Page 2 of 3 PLUMBING & MECHANICAL PERMIT APPLICATION CHECKLIST COMMERCIAL RESIDENTIAL m r- m r- O o SUBMITTAL REQUIREMENTS = c = c T Z Z W Z W m D n Z n Z C D G) D G) m r r Plumbing& Mechanical Permit Application ✓ ✓ ✓ ✓ Mechanical Plans ✓ Structural Calculations ✓ State Non-Residential Energy Code Compliance Form ✓ Manufacturer's Specifications/Cut Sheets ✓ ✓ ✓ Plumbing Plans ✓ Listed &Tested Fire Stopping Assemblies ✓ Elevation View for Roof Mounted Equipment ✓ ✓ Existing Floor Plan ✓ ✓ ✓ ✓ New Floor Plan ✓ ✓ ✓ ✓ NOTE: 1. Handouts and standard details may be found on the City's Planning, Community, & Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, & reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. If installing a backflow prevention device, it will need to pass test results of which will need to be submitted to the city for review. ACKNOWLEDGEMENTS & SIGNATURE By affixing my signature hereto, I certify that I am the owner,or am acting as the Owner's authorized agent, and that the application and documents contained with this submittal are complete and accurate to the best of my knowledge and abilities. SIGNATURE DATE Plumbing/Mechanical Permit Application Updated December 2021 Page 3 of 3 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS,CSA2.33 AND ANSI Z21.66 RESPECTIVELY FOR VENTED GAS FIREPLACE HEATERS l f ■ QUALITY FIREPLACES COS I NSMT INSTALLATION AND OPERATION INSTRUCTIONS FOR GAS-FIRED VENTED ROOM HEATER NA-uwgL c-As MCDLL GI3016-N PRCPANE G4S MODEL G13016-P GAS-ZERO CLEARANCE WHEN INSTALLED WITH GI-700 KIT(FLUSH FRONT&LOUVRES) WITHOUT GI-700 KIT INSTALL RECESSED INTO A WOODBURNING NON-COMBUSTIBLE FIREPLACE CERTIFICATION LABEL AFFIXED TO UNDERSIDE OF FRESH AIR DAMPER WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Immediately call your gas supplier from a • Do not touch any electrical switch. neighbor's phone. Follow the gas suppli- • Do not use any phone in your building. er's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, On., Canada L4M 4Y8 (705)721-1212 Fax.(705)722-6031 Email.ask@napoleon.on.ca HP Web:www.napoleonfireplaces.com R-2000 . . %I. -.r ,.... ,. W415-0171/C/06.11.02 2 X,4TOLEO9Vgas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. M(POLEO9V products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak and test fired at a qualty test station. The complete fireplace is thoroughly inspected by a qualfied technician before packaging to ensure that you, the customer, receives the quality product that you expect from %4POLEOX.. NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY The following materials and workmanship in your new NAPOLEOX gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, phazerTM logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled com- ponents and aluminum extrusion trims. Electrical(110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty. Labour related to warranty repair is covered free of charge during the first year. Wfpair work however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer. CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only--i.e.,the individual or legal entity(registered customer)whose name appears on the warranty registration card fled with NAPOLEON--provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations: This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives. The gas fireplace must be installed by a licenced,authorized service technician or contractor.Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes. This limited warranty does not cover damages caused by misuse,lack of maintenance,accident,alterations,abuse or neglect and parts installed from other manufacturers will nullify this warranty. This limited warranty further does not cover any scratches,dents,corrosion or discolouring caused by excessive heat,abrasive and chemical cleaners nor chipping on porcelain enamel parts,mechanical breakage of PHAZER-logs and embers,nor any venting components used in the installation of the fireplace. NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life,subject to the following conditions:During the first 10 years NAPOLEON will replace or repair the defective parts at our option free of charge.From 10 years to life,NAPOLEON will provide replacement burners at 50%of the current retail price. In the first year only,this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions. After the first year,with respect to this President's Limited Lifetime Warranty,NAPOLEON may,at its discretion,fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaserthe wholesale price of any warranted but defective part(s). After the first year,NAPOLEON will not be responsible for installation,labour or any other costs or expenses related to the reinstallation of a warranted part,and such expenses are not covered by this warranty. Notwithstanding any provisions contained in this President's Limited Lifetime Warranty,NAPOLEON'S responsibility underthis warranty is defined as above and it shall not in any event extend to any incidental,consequential or indirect damages. This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded. NAPOLEON neither assumes,nor authorizes any third party to assume,on its behalf,any other liabilities with respect to the sale of this product.NAPOLEON will not be responsible for: over-firing,downdrafts,spillage caused by environmental conditions such as rooftops,buildings,nearby trees,hills,mountains,inadequate vents or ventilation,excessive venting configu- rations,insufficient makeup air,or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans,furnaces,clothes dryers,etc. Any damages to fireplace,combustion chamber,heat exchanger,brass trim or other component due to water,weather damage,long periods of dampness,condensation,damaging chemicals or cleaners will not be the responsibility of NAPOLEON. The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer.The warranty registration card must be returned within fourteen days to register the warranty. NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS.NAPOLEON®IS A REGISTERED TRADEMARK OF WOLF STEEL LTD.PATENTS U.S.5.303.693.801-CAN.2.073.411,2.082.915&DES 417,497(12.07.1999).©WOLF STEEL LTD. W415-0171/C/06.11.02 3 TABLE of CONTENTS PG 2-4 INTRODUCTION 10-11 OPERATION / MAINTENANCE Warranty Operating Instructions General Instructions Fresh Air Damper System Mantle Clearance Maintenance General Information 11 BLOWER INSTALLATION Care of Glass, Enamelled & Plated Parts Blower Replacement Instructions 5-6 INSTALLATION 11 ADJUSTMENTS Gas Installation Spill Switch Pilot Burner Adjustment Venting Action Check Venturi Adjustments 6-9 FINISHING 12-13 REPLACEMENTS Brick Panel Installation Ordering Replacement Parts Log Placement/Charcoal Embers Replacement Parts Glass, Louvre & Flashing Kit Installation Accessories Logo Placement 14-15 TROUBLE SHOOTING GUIDE PLEASE RETAIN THIS MANUAL FCR FUTURE ITEFINCE WARNING • Adults and especially children should be alerted to It is imperative that the control compartments, the hazards of high surface temperatures and should burners and circulating blower and its passageway stay away to avoid burns or clothing ignition. Su- in the fireplace and venting system are kept clean. pervise young children when they are in the same The fireplace and its venting system should be in- room as the fireplace. spected before use and at least annually by a quali- • Clothing or other flammable material should not be fied service person. More frequent cleaning may placed on or near the fireplace. be required due to excessive lint from carpeting, • Any safety screen or guard removed for servicing bedding material, etc. The fireplace area must be must be replaced prior to operating the fireplace. kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. • This fireplace must not be connected to a chimney Do not use this fireplace if any part has been under flue pipe serving a separate solid fuel burning appli- water. Immediately call a qualified service techni- ance. cian to inspect the fireplace and to replace any part • Do not operate the fireplace with the glass door of the control system and any gas control which removed, cracked or broken. Replacement of the has been underwater. glass should be done by a licensed or qualified serv- Under no circumstances should this fireplace be Ice person. modified. • Do not strike or slam shut the fireplace glass door. Do not burn wood or other materials in this fire- • Due to high temperatures, the fireplace should be place. located out of traffic and away from furniture and draperies. NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN W415-0171/C/06.11.02 4 GENERAL INSTRUCTIONS the absence of local codes, use the current CSA C22.1 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV- CANADIAN ELECTRICAL CODE in Canada or the ICED BY A QUALIFIED INSTALLER to conform with local ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United codes. Installation practices vary from region to region and States. The blower power cord must be connected into a it is important to know the specifics that apply to your area, properly grounded receptacle. The grounding prong must ie: in Massachusetts State: not be removed from the cord plug. • The fireplace damper must be removed or welded in the open Provide adequate ventilation and combustion air. Pro- position prior to installation of a fireplace insert. vide adequate accessibility clearance forservicing and • The appliance off valve must be a"T"handle gas cock. operating the fireplace.Never obstruct the front open- The flexible connector must not be longer than 36 inches. • The appliance is not approved for installation in a bedroom or ing of the fireplace. bathroom unless the unit is a direct-vent. MANTLE CLEARANCE 6"MANTLE In absence of local codes, install to the current CAN1-B149 Mantle clearance,while � 5"MANTLE Installation Code in Canada or to the National Fuel Gas conforming to the 1 6" � Code,ANSI Z223.1,and NFPA 54 in the United States. stated clearance to �4'MANATEE Purge all gas lines with the glass door of the fireplace combustible materials, 1 4' 3"M AN TE removed. Assure that a continuous gas flow is at the can vary according to 1 2' �� burner before installing the door. the mantle depth. 10" Underextreme vent configurations,allow several minutes These clearances do (5-15) for the flame to stabilize after ignition. Altitudes not apply to a GI-700 kit FIGURE 1 greater than 4,000 ft.require a minimum vent run of 12 ft. type installation. The heater and its individual shutoff valve must be discon- GENERAL INFORMATION nected from the gas supply piping system during any pressure FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN testing of that system at test pressures in excess of psig(3.5 TEST-FIRED TO ASSURE ITS OPERATION AND QUAL- kPa). The fireplace must be isolated from the gas supply pip- ITY! Maximum input is 30,000 BTU/hr for natural gas and ing system by closing its individual manual shutoff valve during 24,000 BTU/hr for propane. When the fireplace is installed any pressure testing of the gas supply piping system at test at elevations above 4,500 ft., and in the absence of spe- pressures equal to or less than psig (3.5 kPa). cific recommendations from the local authority having ju- A 1/8 inch NPT plug, accessible for test gauge connection, risdiction, the certified high altitude input rating shall be must be installed immediately upstream of the gas supply reduced at the rate of 4%for each additional 1,000 ft. Maxi- connection to the fireplace. mum output for natural gas is 22,800 BTU/hr at an effi- This fireplace must be connected to any accepted lined chim- ciency of 76% with the fan on, 72% with the fan off; and ney system listed to ULC-S635M (in Canada) or UL-1777 18,240 BTU/hr for propane at an efficiency of 76%with the (in USA). The venting connection must be in compliance fan on, 71%with the fan off. Minimum A.F.U.E.(Annual Fuel with the chimney manufacturers installation instructions. Utilization Efficiency) rating is 64% for both natural and The draft hood must be installed so that it is in the same propane gas. Where the fireplace has been factory atmospheric pressure zone as the combustion air inlet to equipped for hi-altitude, the input has been downrated by the fireplace. 10%. This fireplace is approved for bathroom, bedroom This heater can be installed two different ways. If installed and bed-sitting room installations and is suitable for mo- as is, it must be recessed into a vented noncombustible bile home installation. woodburning fireplace(prefabricated or masonry)only.This Minimum inlet gas supply pressure is 4.5 inches water is referred to as an INSERT type of installation. column for natural gas and 11 inches water column for The minimum fireplace size in which the heater is to be propane. Maximum inlet gas pressure is 7 inches water installed is: HEIGHT 21 inches column for natural gas and 13 inches water column for WIDTH 261/2 inches propane. Manifold pressure under flow conditions is 3.5 DEPTH 17%inches inches water column for natural gas and 10 inches water If installed in conjunction with kit#GI-700, it may be framed column for propane. into an enclosure made of combustible materials. This is No external electricity(110 volts or24 volts)is required referred to as a ZERO CLEARANCE type of installation. for the gas system operation. This heater may only be installed in the GI-700 when using Change in flame appearance from "HI" to "LO" is more the glass front kit, GI-FF, as well as one louvre kit, GI-LPB, evident in natural gas than in propane. The self generating GI-LAB, GI-LG or GI-LK. The minimum clearance to com- pilot provides current for a remote burner On-Off switch. bustible construction in this form of installation is: CARE OF GLASS, ENAMELLED AND MANTLE HEIGHT* 7 inches** PLATED PARTS SIDES,BACK,BOTTOM&TOP 0 inches 1 Do not use abrasive cleaners to clean these parts. Buff B-VENT inch RECESSED DEPTH 1 inches lightly with a clean dry cloth. Porcelain enamelled compo- MEASUREMENTS TAKEN FROM KIT STANDOFFS.SEE KIT INSTRUCTIONS nents must be handled with care. The baked-on finish IS **MAXIMUM HORIZONTAL EXTENSION IS 6 INCHES. glasslike. If Struck, it will chip! Touch-up paint is available Objects placed in front of the fireplace must be kept a through your Napoleon dealer. minimum of 48"away from the front face. The glass is 3/16" ceramic glass available from your Na- The fireplace, when installed, must be electrically con- poleon dealer. DO NOT SUBSTITUTE MATERIALS. Clean nected and grounded in accordance with local codes. In the glass after the first 10 hours of operation with a recom- mended gas fireplace glass cleaner. Thereafter clean as W415-0171/C/06.11.02 required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent discolouration and / or blem- ishes may result. 5 INST LION 22-3 4" FIGURE4 15-1/4" EVELING SCREWS 0 2 6" 30-1/4" J I� 1 2-1/2" 3-1/2" _ Levelling the insert will eliminate rocking or excessive FIGURE2 noise when the fan is in operation. Replace the securing 20-5/8" screw to the front of the dilution plate. FLEXIBLE SHUT OFF MMffZZC VALV ADAPTER FIGURE S FITTING GAS SUPPLY FRESH Al R BLACK 3-1 a Install rigid black pipe, a flex connector, if local codes per- 2-1/2" .e97-1/2" y/ mit, or 1/2"type L, copper tubing with a 3/8"to 1/2"adapter 3-1/2" and a shut off valve to the fireplace. Seal and tighten se- curely. The adapter will be required between the gas valve INSTALLATION and the copper tubing or flex connector. Clean out the ashes from the inside of the woodburning Do not damage or kinkf/exconnector! fireplace. Make sure that the chimney and woodburning fireplace are in clean and sound condition. Do not remove Check for gas leaks by brushing on a soap and water bricks or mortar from the masonry fireplace. If necessary solution. have any repair work done by a qualified person before Do not use open flame! installing the insert. Remove the existing fireplace damper An on/off switch has been included and can be located at or lock into an open position. Line the chimney with a 4 the lower right, behind the louvre access door or at the inch diameter approved liner. Pack insulation around the right side trim. liner in the damper area to prevent air flow from entering For ease of accessibility, this switch may be replaced with the chimney. Chimney installation must conform to both a wall switch or substituted with a millivolt thermostat that national and local code requirements. The liner must be may be installed in a convenient location on any wall. Route continuous from the fireplace to the chimney cap. 2-strand (solid core) millivolt wire through the electrical hole located at the bottom right side of the unit.The recom- mended maximum lead length depends on wire size: DILUTION 7DR° WIRE SIZE MAX.LENGTH HOOD 14gauge 100 feet DILUTION 16gauge 60 feet IPLATE 18gauge 40 feet SECURING CLIPS . FIGURE 3 2 t� 41 Remove the securing screw from the front of the dilution plate. Push the dilution hood out of its securing clip and FIGURE6 attach the liner using 3 screws equally spaced. Move the insert into the centre of the woodburning fireplace making Attach the two leads to terminals 1 and 3 located on the sure that the dilution draft hood inserts back into its secur- gas valve. ing clip. Level using the four levelling screws located front Do not connect either the wall switch or the gas valve to and back on either side of the fireplace base. electricity(110 volts or24 volts). W415-0171/C/06.11.02 6 SPILL SWITCH This is a thermally activated switch, attached to the back of the unit and extending up into the dilution draft hood,which FIGURE8 senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a \ blocked or disconnected vent. It acts as a safety shutoff to prevent a build up of carbon monoxide or an explosion of SATISFACTORY UNSATISFACTORY unburnt gases during start up. If the flue is blocked or has no "draw", the spill switch will automatically shut off the TAMPERING WITH THE SWITCH CAN RESULT IN supply of gas within about 5-10 minutes. CARBON MONOXIDE (CO) POISONING AND POS- SIBLE DEATH. VENTING ACTION CHECK:A check for correct venting action must be made before the installed insert is left with the customer. Test after installing the unit into either the GI-700 ZERO ® CLEARANCE KIT or a vented noncombustible fireplace in SPILL the following manner: TuaE 1. Close all doors and windows in the room/start exhaust fans in the home/turn fireplace blower off. 2. Set controls to"high" and light the unit. /,zN\_E_ 33. Wait5 minutes. Light a match and hold it to the spill tube opening. 4. Venting action is satisfactory if smoke is drawn into the Jj spill tube. Venting action is unsatisfactory if the flame and smoke are not drawn into the tube. FIGURE 7 5. If venting action is unsatisfactory,turn the unit off,wait 10 minutes and try again. If the smoke or flame is still not drawn into the spill tube, turn the unit off and check for adequate fresh air supply, vent blockage or restriction. If necessary, consult with a qualified inspector. FINISHING OPTIONAL BRICK PANEL INSTALLA- TION Remove the secur- ing screws located , on either of the fire- box sides as illus- trated. Remove protective plastic wrap from all four panels. Centre the rear brick panel " h against the back of the firebox. Place the left brick panel FIGURE9b against the left side of the firebox, When shipped, the brick panels range in colour from ensuring that it white to varying shades of brown.During initial use,the butts up to the rear FIGURE9a panels will darken temporarily and emit a slight odour panel. for a few hours. This is a normal condition that will not Excess material may be trimmed with a utility knife. Secure occur again.Simply open a window to sufficiently venti- in place using a retainer bracket and 2 of the screws. Re- late the room. The appearance of the panels will perma- peat for the right side. nently lighten in colour with use. W415-0171/C/06.11.02 7 LOG PLACEMENT INSTRUCTIONS / CHARCOAL EMBERS PHAZERTI logs and charcoal embers, exclusive to Napo- POSITIONING THE LOGS IMPROPERLY WILL CAUSE leon Fireplaces, provide a unique and realistic glowing FLAME IMPINGEMENT AND CARBONING. effect that is different in every installation. Take the time to carefully position the charcoal embers for a maximum glow- ing effect. BACK LOGA=; RIGHT FIGURE 10 ^/ Loc _� �� LOG Fa BUPPOR RACKET LEFT EROKT LOG t SKEWERING Loc% \ —� _ _._ —...+e._._.—. _ a SCREW ��A's � CENTRE / 6� O r LOG � -� � � �\ CHARCOAL EMBERS 1. Place the front log onto the main burner, pushing it CHARCOAL EMBERS: Randomly place the embers along as close as possible to the burner ports without the front burner ports. Keep ember dust away from burner blocking/covering them.The left and right spacing between ports to avoid plugging them. the log ends and the burner ports should be equal. Fine dust found in bottom of bag not to be used. 2. Place the back log onto the log support brackets PHAZERTM logs and charcoal embers glow when exposed located on the rear wall of the combustion chamber. The to direct flame. Use only certified PHAZERTM logs and char- notch situated at the lower left of the back log should be coal embers available from your Napoleon dealer. centred evenly above the pilot assembly. 3. While supporting the back log, to prevent it from falling forward, set the three smaller logs into the pockets and grooves of the front and back logs, respectively. T+ Log colours may vary. During the initial use of the fire IGURE 11 place,the colours will become more uniform as colour J \� pigments burn in during the heat activated curing proc- e ss. � s - _e_ W415-0171/C/06.11.02 8 GLASS & OPTIONAL KIT INSTALLATIONS FLUSH FRONT LOUVRES, GI-LK, GI-LPB, GI-LAB, FLUSH GLASS FRONT KIT, GI-FF: Attach the lower GI-LG: Install the louvres and louvre assembly as illus- glass bracket. Seat the glass inside the bracket and using trated in FIGURES 12a AND 13. two screws attach the upper glass bracket, and the upper glass bracket cover as shown. The louvre assemblies are installed as illustrated in Figures 12a and 13. The upper glass bracket cover is formed with tabs to create a gap for air flow and must not be adjusted. LOWER LOUVRE ASSEMBLY FIGURE 13 BRACKET COVER ORNAMENTAL FLUSH INSETS,GI-OIK,GI-OIG:As- BRACKET semble the flashing and mount to the inside of the outer shell using 4 securing screws and spacers (supplied) as GLASS J shown. Hook the ornamental inlays over the spacers. UPPER LOUVRES-3 PC SET FIGURES 12a ++-� UPPER GLASS BRACKET III'MFIIIkI111111p11M11HILdIkI11h11111LI111Li1r'!II UPPER GLASS BRACKET COVER — - Assemble the flashing and mount to the inside of the outer shell using 4 securing screws (supplied with the louvre kit). FIGURES 14 SECURING SCREW ` LOCATIONS LOWER GLASS BRACKET FIGURE 12b LOGO PLACEMENT UPPER LOWER LOGO - Remove the backing of the logo supplied and place on the glass viewing area, as indicated. W415-0171/C/06.11.02 9 BAY GLASS FRONT, i GI-BF:With the bay chas- sis on a flat surface, in- sert the front glass (bot- — _ tom first) and centred to ETAINERTAB the mitred edges of the chassis. Fit the bevelled edge of the each side glass piece tightly to either edge of the FIGURES 15 front glass. Secure the glass by bend- ing up the retainer tabs at the top and bottom. 71 J FIGURE 17 Spread and insert the c LIP spring clips between the ORNAMENTAL BAY INSETS,GI-OIK,GI-OIG: side glass and the chas- sis (2 per side). - -- Place the front brick panel pieces into place at the bottom. Secure the bay to the insert front at the top and bottom outside corners using screws.4 BAY LOUVRES,GIB-LK,GIB-LPB,GIB-LAB,GIB-LG: , Note: Black louvre assembly,if supplied,must be installed as uppers, due to the high fireplace temperature. 1 r}.r FIGURE 18 Both these options may be attached to the insert front using 4 magnets, posi- tioned as shown: NOTE:The ornamental bay MAGNET inlays can be adjusted to align with the bay door as- sembly. FIGURE 16 FIGURE 19 - W415-0171/C/06.11.02 10 OPER411ON / MAINTENANCE OPERATING INSTRUCTIONS FRESH AIR DAMPER SYSTEM When lit for the first time, the stove will emit a slight odour If your masonry fireplace is equipped with a fresh air inlet for a few hours. This is a normal temporary condition in the floor of the firebrick chamber, the insert is able to caused by the curing of the logs and the "burn-in" of inter- take outside air directly into the unit through an opening in nal paints and lubricants used in the manufacturing proc- its base thereby eliminating the need to use preheated ess and will not occur again. room air for combustion. The flow of air may be adjusted Simply open a window to sufficiently ventilate the room. through the use of a damper located below the louvre ac- After extended periods of non-operation such as following cess door. The damper should be kept closed (pushed all a vacation or a warm weather season, the fireplace may the way in)when the unit is not in operation or if no outside emit a slight odour for a few hours. This is caused by dust air is available. The damper is fully open when pulled for- particles in the heat exchanger burning off. Open a window ward (one inch from the closed position). to sufficiently ventilate the room. FIGURE 20 I "CEOSE DAMPER Never obstruct the flow of combustion or ventilation air. FORYOUR SAFETY READ BEFORE OPERATING A This stove has a pilot which must be lit by hand while Call a qualified service technician. Force or attempted following these instructions exactly. repair may result in a fire or explosion. B Before lighting, smell all around the fireplace area for D Do not use this insert if any part has been under water. gas and next to the floor because some gas is heavier Immediately call a qualified service technician to inspect than air and will settle on the floor. the unit and replace any part of the control system and C Use only your hand to push in or turn the gas control any gas control touched by water. knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. Immediately call your gas supplier from a neighbour's • Do not touch any electrical switch;do not use any phone phone. Follow the gas supplier's instructions. in your building. • If you cannot reach your gas supplier, call the fire de- partment. LIGHTING INSTRUCTIONS: 1. Stop! Read all the safety information above. When 8. Depress and hold the gas knob while lighting the pilot lighting and relighting, the gas knob cannot be turned with the push button igniter. Keep the knob fully de- from "pilot" to "off' unless the knob is depressed. pressed for one(1)minute,then release. If the pilot does 2. Turn off all electrical power to the stove. not continue to burn, repeat steps 3 through 7. 2. Turn the gas knob�.k clockwise to off. 9. With the pilot lit, turn the gas knob counter-clock- 4. Wait 5 minutes for any gas in the combustion cham- wise` to "on" position. ber to escape. Continue to the next step if you do NOT 10. If your insert is equipped with a flame adjustment smell any gas. If you smell gas, STOP! and follow the valve, push and turn the knob to "high". instructions in "What to do if You Smell Gas"listed above. 11.If your insert is equipped with a remote"on-off'switch, 5. If the unit is equipped with a flame adjustment valve, the main burner may not come on when you turn the gas turn clockwise to off. .+ valve to "on" or"high". The remote switch must be in the 6. Locate the pilot situated in front of the rear log. "on"position as well to ignite the main burner. 7. Turn the gas knob counter-clockwise to "pi- 12. Turn on all electrical power to the insertF R ]l _ lot" position. U u INSTRUCTIONS TO TURN OFF GAS: 1. Turn off all electrical power to the unit if service is 2. Push in gas control knob slightly and turn clock- to be performed. wise to off.�JDo not force. W415-0171/C/06.11.02 11 MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE. 3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- fac properly. (right brick panel must be removed in order to gerous operation. Verify proper operation after servicing. facilitate burner removal) This insert and its venting system should be inspected 4. Check to see that the pilot flame is large enough to before use and at least annually by a qualified service per- engulf the thermopile on one leg and reaches toward the son. The fireplace area must be kept clear and free of burner on the other leg. combustible materials, gasoline or other flammable va- 5. Replace the cleaned logs. pours and liquids. The flow of combustion and ventilation 6. Check to see that the main burner ignites completely on air must not be obstructed. all openings when the gas knob for the burner is turned 1. In order to properly clean the burner and pilot assembly, on. A 5 to 10 second total light-up period is satisfactory. If remove the logs to expose both assemblies. ignition takes longer, consult your Napoleon dealer / dis- 2. Keep the control compartment, logs, burner, air shutter tributor. opening and the area surrounding the logs clean by vacu- 7. Check that the gasketing on the door is not broken or uming or brushing, at least once a year. missing. Replace if necessary. FERLAMAENT WERINSTAL BLOWER SYSTEM BLOWER REPLACEMENT IN- The Napoleon gas fireplace insert comes standard with a STRUCTIONS: blower, a heat sensor, variable on/off speed control and a Turn off the gas and electric power to the unit. power cord. Because the blower is thermally activated, Remove the glass door. when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approxi- Remove the lower glass bracket. mately 30 minutes after the fireplace has been turned off. Remove the logs. Use of the fan increases the output of heat. Air, drawn in Remove the burner assembly. (right brick panel must through the lower louvre access door, is driven up the back be removed in order to facilitate removal) of the firebox, and exhausted as hot air between the upper Remove the four screws holding the access door in louvres. place on the control assembly (located to the back of G FIGURE21 the burner assembly.) For location, see picture in re- B placement parts. ~L SOR/\/\/� AT SLN Disconnect the electrical connectors at the blower. W VARIABLE SPEED SWITCH _ LAN �� Remove the blower. Drywall dust will penetrate into blower bearings causing irrepairable damage and must be prevented from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy. MJUSMENTS VENTURI ADJUSTMENT PILOT BURNER ADJUSTMENT Natural gas models have air shutters set at 1/16 (.063") 1. Remove the pilot adjustment cap. inch open. Propane gas models have air shutters set at 2. Adjust the pilot screw to provide properly sized flame. [5/161 (.313) inch open. Closing the air shutter will cause a 3. Replace the pilot adjustment cap. more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause t THERMOPILE t flame lifting from the burner ports. The flame may not ap- pear yellow immediately; allow 15 to 30 minutes for the # final flame colour to be established. AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BYA - _ QUALIFIED GAS INSTALLER! ORIFICE VENTURI F.IGURE23 PILOT ADJUSTMENT CAP * FIGURE22 PILOT ASSEMBLY FIGURE 24 Ak FLAME MUST ENVELOP UPPER AIR SHUTTEROPENING s/16"TO'/i"OFTHERMOPILE W415-0171/C/06.11.02 12 FIRLACM EN TS ORDERING REPLACEMENT PARTS 1. Model &Serial Number of the unit. Contact your dealer or the factory for questions concerning 2. Installation date of the unit. prices and policies on replacement parts. Normally all parts 3. Part Number can be ordered through your Kenmore dealer or distribu- 4. Part Description tor. When ordering replacement parts always give the fol- lowing information: 5. Finish W135-0009 W135-0015 W550-0001 �� W135-0007 W135-0052 REPLACEMENT PARTS LIST - W135-0016 - PART NO. DESCRIPTION -- - -''-- - GL-610 GZ-551 REPLACEMENT BLOWER W725-0036 NATURAL GAS VALVE C/W ADJUSTABLE REGULATOR W01 0-0333 W725-0037 PROPANE GAS VALVE C/W ADJUSTABLE REGULATOR W455-0004 #36 DMS NATURAL GAS BURNER ORIFICE W455-0003 #54 DMS PROPANE GAS BURNER ORIFICE W455-0013 #37 DMS NATURAL GAS BURNER ORIFICE-HIALT W455-0002 #55 DMS PROPANE GAS BURNER ORIFICE-HIALT W562-0012 W660-0007 SPILL SWITCH(NATURAL GAS) W660-0006 SPILL SWITCH(PROPANE) W010-0337 NATURAL GAS PILOT ASSEMBLY W357-0001 W010-0338 PROPANE GAS PILOT ASSEMBLY 1y ACCESS W357-0001 PIEZO IGNITER W680-0004 THERMOPILE W690-0002 THERMAL SENSING SWITCH GZ551 W660-0009 BURNER ON/OFF SWITCH CONTROL ASSEMoBLY W135-0007 BACKLOG W690-0002 W135-0052 FRONT LOG W010-0337/ KB 35 0 W135-0015 RIGHT LOG W680-0004 W010-0338 W135-0009 CENTER LOG W135-0016 LEFT LOG I-0025/ GL-610 LOG SET C/w CHARCOAL EMBERS -0006 DOOR N W550-0001 CHARCOAL EMBERS W455-0004/ 660-0007/ W010-0333 BURNER ASSEMBLY W455-0003/- 660-0006 W455-0025 NATURAL GAS PILOT ORIFICE W455—o013/ W455-0006 PROPANE GAS PILOT ORIFICE W455—000z W385-0245 NAPOLEON LOGO LOUVRES W562-0012 DOOR GASKET(2PC-SIDE) W725-0036/ KB 35 VARIABLE SPEED SWITCH W725-0037 GI-LK, GI-LPB, GI-LAB, GI-LG ACCESSORIES / OPTIONS PART NO. DESCRIPTION W660-0009 GI-FF FLUSH GLASS DOOR ASSEMBLY W300-0012 DOOR GLASS W562-0011 DOOR GASKET-TOP GI 900K /9, GI-900AB6/9, 113I-900B /9, GI-BF BAY GLASS DOOR ASSEMBLY GI 09K6 9, G1909S6/9, GI-909F6/9 W010-0325 SIDE BAY DOOR GLASS-EACH C/W GASKET W010-0326 FRONT BAY DOOR GLASS C/W GASKET LOUVRE KITS FOR THE FLUSH DOOR ASSEMBLY GI-LK UPPER&LOWER LOUVRES(BOTH BLACK)C/W TRIM GI-LPB UPPER(BLACK)&LOWER(POLISHED BRASS)LOUVRES C1W TRIM GI-LAB UPPER(BLACK)&LOWER(ANTIQUE BRASS)LOUVRES C/W TRIM GI-LG UPPER&LOWER LOUVRES(BOTH GOLD PLATED) GI-LSS UPPER(BLACK)&LOWER(BRUSHED STAINLESS STEEL)LOUVRES C/W TRIM LOUVRE KITS FOR THE BAY DOOR ASSEMBLY GIB-LK UPPER&LOWER LOUVRES(BOTH BLACK)C/W TRIM GIB-LPB UPPER(BLACK)&LOWER(POLISHED BRASS)LOUVRES C1W TRIM GIB-LAB UPPER(BLACK)&LOWER(ANTIQUE BRASS)LOUVRES C/W TRIM GIB-LG UPPER&LOWER LOUVRES(BOTH GOLD PLATED)ASSEMBLY GIB-LSS UPPER(BLACK)&LOWER(BRUSHED STAINLESS STEEL)LOUVRES C/W TRIM ORNAMENTAL INSET KITS FOR THE FLUSH DOOR ASSEMBLY GI-OIK UPPER&LOWER ORNAMENTAL INSETS(BOTH BLACK)FOR FLUSH DOOR ASSEMBLY C/W LOWER DOOR TRIM GI-OIG UPPER&LOWER ORNAMENTAL INSETS(BOTH GOLD PLATED)FOR FLUSH DOOR ASSEMBLY ORNAMENTAL INSET KITS FOR THE BAY DOOR ASSEMBLY GIB-OIK UPPER&LOWER ORNAMENTAL INSETS(BOTH BLACK)FOR BAY DOOR ASSEMBLY C/W LOWER DOOR TRIM GIB-OIG UPPER&LOWER ORNAMENTAL INSETS(BOTH GOLD PLATED)FOR BAY DOOR ASSEMBLY W415-0171/C/06.11.02 13 GI 778KT BRICK PANEL KITS W470-0002 ENAMEL TOUCH UP AND BRUSH (SPECIFY COLOUR) , GI 700KT ZERO CLEARANCE SHELL 111-KT OUTSIDE AIR KIT W690-0001 MILLIVOLT THERMOSTAT , W660-0010 REMOTE CONTROL-ADVANTAGE W660-0011 REMOTE CONTROL-ADVANTAGE PLUS GD 660 WALL SWITCH/20FT WIRE W500-0033 V.S.S.MOUNTING PLATE FOR WALL SWITCH ' GD240-K WEBBED DOOR FACIA f FLASHING SURROUNDS: { GI-900AB6 ANTIQUE BRASS FLASHINGS-6" GI-900136 POLISHED BRASS FLASHINGS-6" GI-900K6 BLACK FLASHINGS-6" GI-900AB9 ANTIQUE BRASS FLASHINGS-9" GI-900139 POLISHED BRASS FLASHINGS-9" `'j ,�F --- GI-900SS6 BRUSHED STAINLESS STEEL FLASHINGS-6" �' _ GI-900SS9 BRUSHED STAINLESS STEEL FLASHINGS-1 GI-900K9 BLACK FLASHINGS-9" ¢1 GI 700KT -� GI-909S6 PORCELAIN ALMOND FLASHINGS-6" GI-909F6 PORCELAIN GREEN FLASHINGS-6" GI-909K6 PORCELAIN BLACK FLASHINGS-6" GI-909S9 PORCELAIN ALMOND FLASHINGS-9" GI-909F9 PORCELAIN GREEN FLASHINGS-9" W562-001 1 GI-909K9 PORCELAIN BLACK FLASHINGS-9" (GASKET END UP) W175-0145 CONVERSION KIT- NAT-LP W175-0146 HIGH ALTITUDE CONVERSION KIT-NG-LP W300-0012 W175-0148 HIGH ALTITUDE CONVERSION KIT-NG-NG FC-12 12"STAINLESS STEEL GAS FLEX CONNECTOR CISK CAST IRON SURROUND -PAINTED BLACK CISKK CAST IRON SURROUND - PORCELAIN ENAMEL BLACK GI-FF CISKN CAST IRON SURROUND - PORCELAIN ENAMEL MAJOLICA BROWN CISKB CAST IRON SURROUND - PORCELAIN ENAMEL MAJOLICA BLUE CISKF CAST IRON SURROUND - PORCELAIN ENAMEL MAJOLICA GREEN ANI-K ANDIRONS - PAINTED BLACK ANI-G ANDIRONS-GOLD PLATED J�- IPW690-0001 W010-032 W01 -0326 I 111 KT 1 GI-BF CISK GD240-K ••���. �o� Boa W475-0144 0� \ GI-778KT \ W475-0145 ANI-K/ANI-G \ W475-0142 GIB-LK, �� GIB-OIK, � � ._ ®�a°oo®Oogo opQop _ GI-OIK, ®pQpmo®q® GIB-LPB, y -- GIB-OIG - GI-OIG GIB-LAB,GIB-LG opaQ�o W415-0171/C/06.11.02 14 TROUBLE SHOOTING GUIDE B OREATTEMPTINGTOTROUBLE SHOOT,PURGEYOURUNITAND INITIALLY LIGHTTHEPILOTANDTHE MAIN BURNERWITH THE GLASS DOORREMOVED. SYMPTOM PROBLEM TEST SOLUTION Pilot goes out when the A - System is not correctly - purge the gas line with the glass door removed. gas knob is released. purged. B -Out of propane gas. - fill the tank and purge the gas line with the glass door removed. C - Pilot flame is not - turn up the pilot flame. large enough D - Pilot flame is not engulfing - gently twist the pilot head to improve the flame pattern the thermopile. around the thermopile. E - Thermopile shorting. - clean thermopile and valve connection. - check that thermopile insulation is not frayed and ground- ing out on the housing or the burner support. - replace thermopile. - replace valve. F- Faulty thermopile. - test& replace if necessary. G-Faulty valve. - test& replace if necessary. Pilot burning; no gas to A-Wall switch is defective - connect a jumper wire across the wall switch terminals; main burner; gas knob if the main burner lights, replace the wall switch. is on;wall switch is on; heat/flame adjustment B - Wall switch wiring is defec- - disconnect switch wires from valve and connect a jumper valve is on (if so tive. wire across terminals 1 and 3; if the main burner lights, equipped. check the wires for defects and/or replace wires. C- Main burner orifice is - remove stoppage in orifice. plugged. D - Remote gas valve operator - connect a jumper wire across terminals 1 and 3; if main is defective. burner does not light, replace gas valve. Pilot goes out while Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, standing; Main burner diminishes or extinguishes, especially when main burners is in 'OFF' position. ignite. Monitor supply pressure. - check if supply piping size is to code. Correct all under- sized piping. Pilot will not light. A- No spark at pilot burner - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening. replace pilot assembly if the wire insulation is broken or /,s'TO'/8' frayed. - replace pilot assembly if the ceramic insulator is cracked i or broken. - replace the push button ignitor. B - Spark gap is incorrect - spark gap should be 1/16" to 1/8" from the electrode tip i and the pilot burner. Light the pilot with a match and adjust the electrode tip to the required spark gap and proper loca- tion. C - No gas at the pilot burner - check that the manual valve is turned on. - check the pilot orifice for blockage. IGNITER I E z O - replace the valve. THERMO- P I L O T - call the gas distributor. PILE BURNER D -Out of propane gas - fill the tank and purge the gas line with the glass door removed. W415-0171/C/06.11.02 15 SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; A- Refer to"Main burner goes out; pilot stays on" pilot goes out. B - Chimney down-drafting - wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer. Open windows and/or doors. Start fireplace and monitor its operation. Close doors and windows and start appliances as before; room is in negative pressure; increase fresh air supply. C - Chimney is blocked - check for chimney blockage. D - Liner disconnected from in- - re-attach liner. sert. E- Faulty spill switch. - replace. Carbon is being de- Air shutter has become blocked - ensure air shutter opening is free of lint or other obstruc- posited on glass, logs tions. or combustion cham- ber surfaces. Flame is impinging on the logs - check that the logs are correctly positioned. or combustion chamber. - open air shutter to increase the primary air. - check the input rate: check the manifold pressure and orifice size as specified by the rating plate values. - check that the door gasketing is not broken or missing and that the seal is tight. -check that the 4"vent liner is free of holes and well sealed at all joints. -check that minimum rise per foor has been adhered to for any horizontal venting. Exhaust fumes Fireplace is spilling. - check for chimney blockage. smelled in room, head- - check that chimney is installed to building code. aches. - room is in negative pressure; increase fresh air supply. White/grey film forms. Sulphur from fuel is being de- - clean the glass with a gas fireplace glass cleaner. DO posited on glass, logs or com- NOT CLEAN GLASS WHEN HOT. bustion chamber surfaces. If deposits are not cleaned off regularly, the glass may be- come permanently marked. Remote wall switch is A- Wall switch is mounted up- - reverse. in off position; main side down. burner comes on B - Remote wall switch is - replace. when gas knob is grounding. turned to "ON" posi- tion. C - Remote wall switch wire is - check for ground(short); repair ground or replace wire. grounding. D-Faulty valve. - replace. Main burner flame is a A- Insufficient secondary air. - increase fresh air supply(open door,window,add make- blue, lazy, transparent up air supply) flame. B - Downdraft or blockage in - remove blockage. chimney. - check that chimney is installed to building codes (3ft above highest roof line or 2ft higher than any portion of a building within a horizontal radius of 1Oft of the chimney.) Main burner goes out; A - Pilot flame is not large - turn on pilot flame. Gently twist the pilot head to improve pilot stays on. enough or not engulfing the ther- the flame pattern aroung the thermopile. mopile. B - Thermopile shorting. - clean thermopile and thermopile connection to valve. W415-0171/C/06.11.02 A Napoleon Fireplace Service History g This fireplace must be serviced annually depending on usage. J Date Dealer Name Service Technician Service Performed Special Concerns Name N