Loading...
HomeMy WebLinkAboutPermit File 5508 Doon Way (2) pp i F�LG - - bJ&. '� %*,F LAND Residential Building Permit Application City of Anacortes Building Department P.O. Box 547 Anacortes, WA 98221 Street Address: 904 6th Street Phone: (360) 293-1901 Fax: (360) 293-1938 SITU ADDRESS: O :3 CONTRACTOR ❑:Applicant PROJECT DESCRIPTION Name lag'tt) CtCd( 'tAi 614g Co 401c?I 0 L tplA Address 3L{0? F /U€ City/State/Zip 414aC 0"‘lS/ WA 5922( Phone. C •-.Sal0-Zit(k'AX State License# Exp PARCEL NUMBER City of Anacortes Business License:6 Yes ❑No PROPERTY OWNER ❑Applicant LEGAL DESCRIPTION Name rtc t>n K e„,vi L' Address City/State/Zip Ai"<Ca,►1PS/ l✓A fen(( PROJECT VALUATION �,Z. ,o? 0 6 Phone 360-Zi 3^34"1 FAX 7 v r Numbelof Dwelling Units- - . E-Mail Address sex*/Ztil tj QJvtv�;, ,ate Number of Stories Building Area: ❑Architect 0 Designer Engineer Engineer❑ Applicant PI Floor s.f. 2nd Floor s.f. Name p['Ail t/In C t- y eg/51/ L L 3`d Floor s.f. Basement s.f. Address -0 car. 1 ` - Garage s.f. Carport s.f. City/State/Zip Alta CD( ( /AA qi-221 Deck s.f. Lot Area s.f. Phone g60--3°1/-0/3FAX E-mail Address q 1f tGi,t,� S/ at 1 ,iLt i CONTACT - ❑Applicant; LENDER � LENDER INFORMATION MUST BE PROVIDED FOR PROJECTS OVER$5,000 f Name �,.\ V1 �t!`�\ IN VALUATION PER RCW. Address 31f ne P Atvk Name City/State/Zip Zlef C(1411'3 1.4 4i22( Address Phone 3b1 —fl(t)'2?IGFAX City/State/Zip r E-mail Address / ) / Phone No. J,,1,‘ �) new Cs cc;Y`cO 4 Otit CONTINUED ON THE BACK l5- v7cD SKYLINE PROPERTY OWNERS ASSOCIATION ARCHITECTURAL COMMITTEE 6041 Sands Way, Anacortes, WA 982211 Phone: 360-293-0498 Fax: 360-293-2981 NOTICE OF PLAN APPROVAL Div. / , Lot // Owner: /43v i el /eel/ l Address: SO g c��, W� Your plans for �v 'e � were reviewed and approved by the SPOA Architectural Committee on . Two copies of the plans are attached, one for you and one for submitt t the City of Anacortes for building permit. If a building permit for your project is not required by the city, one copy is attached. it , '.. e -7; 'J'/ r."j//i/e73/1) Please note the followmg conditions of'approvala in accordance with the CC&R's: 1. The work of construction of all buildings shall be prosecuted diligently and continuously from commencement of construction until exteriors of such buildings are completed and painted or otherwise suitably finished. Exterior work on any building shall be completed within one year from start of construction. 2. When all exterior construction and/or improvements have been completed Owner shall promptly notify the Architectural Committee in writing so as to facilitate its inspection buy one or more members of the committee. 3. If construction has not started within one year from date of approval then approval shall be deemed null and void, unless and extension has been applied for and a valid reason for delay has been provided. If you have any questions please contact the Architectural Committee at the above number. SPOA Architectura Committee, ;- Member i I --� , Member 32'4 1/2"ADDITION ® 4 10'-8 3/4" 10'-6" 10'-10 3/4" / A l2'-0" I 8'-4" l Deck Height 25"(<30") Landing And 4 Above Existing Grade Steps To Grade ~ - All t , 3.125x7.5 GLAM 1 Q /1- ° Top Of Spa Approx.18"Above Deck X v I 4x4 Posts,Simpson I N Architectural HL43PC Connectors x2 Where Possible In 6 p q \ z O I\ o'/I \ /I . ' r----F\.e/I I\-�/1 I Q I��`i\ I \ I� � I 1crIV\ I ice / I - tO I I \ A/ \I I/ \I I//\\I 0 N 14---4 / vim.—__,1 ---4 k_--_4 Zsi Q `•-) Jetted Swim Spa Covered Deck . `° 31'$„ / , ' / Dining Waterproof Wall Covering ; \ - _ il r 5 ' 10 Kitchen < Bathroom4, - s I • ,. - Garage I K______— o 2. N / Living Bedroom 3'-0" ' fV Porch ------.) ---- ----...--j 0 1 Bathroom l 18'-0" 9'-0" — 7 / / } s, I70 Media i Bedroom 4 Plan /444 Floor Plan - 0 2 5 10 Scale: 1/4"=1' 25'-0" 7/ A 32'-1 1/2"ADDITION /,' ``�/, `•�,_~+N.' 10'-8 3/4' 10'-6" 10'-10 3/4" I USE zMAX CONNECTORS AND HOT DIPPED \‘ ' /7 GALVANIZED FASTENERS OR EQUIVALENT I 4x4 Posts,Simpson ABU44 WHEN IN CONTACT WITH TREATED WOOD. 1, Elevated Post Bases i- -I % ALTERNATE:PROVIDE 30# FELT BETWEEN 2x10 PT Rim/LUS210Z Hangers 8"Sonotube,24"Sq Footing 2x10 PT Rim —r — — — �i —— — — —— `� _— — — — mi 0—I •` TREATED WOOD AND METAL CONNECTIONS. �/ L • �-h I 12� I �-� I I L T J I r„ PT 4x8 Beam I —I 1 7 J I I I--h I I I �-� I o • ��_,�/ • L i�■�ii�■ii[1iiii� It-1 I I I I L j 16'-0"Tvp 4"I 1.-2" . , II I I I I °r 2x10 Joists @ 16"O.C. I I I i I I i i, 2x10 PT Rim/LUS210Z Hangers I6-eL I I I 1 , I� I I I I I I I I 1 1 1 1 Ilrilliii l l I I 1' I I I ; I I I I PT414 Posts 1 1 1 Optional Section/6"Conc.Slab I I f �2 Co�1c.Footing I I I 1 �I1 I 1 1 I I 12x L H-- 11 t— ']'I 1 I ......I L 11 I I * 1 -I PT x8 B am I L`-!1 I 1 I LL J - 1• I 1 - r 1 I I 1 �1, 1 1 I I I f 1 I 1 I I I 1 ,,i4-0 1 1 ' I I 1I I I I I I I I I I I I I Dining _1ME'_ 2x10 PT Rim/LUS210Z Hangers - 10 • a Gara9 Kitchen ( r, Bathroom z _ 41, Plan As4 Foundation Plan , i 0 i 2 5 10 I I I Scale:1/4"=1' I I 5508 Doon Way August 13, 2014 z W PROPERTY LINE 75.00- 21-5 Steps TO G,OCe.<3b'H Vemv 20 .11 Existing -Garage to T 3 v T Site Plan 1 0 10 Scale: i” = 20' 1 c Existing i a Residence Porch 1 �, I W 1 K 1 n 20'Sefback 1 Lot 71, Div 7 155081 SS LINE 75.00' Doon Way 30 50 Anacortes, Washington PROJECT INFORMATION: vF Ems'5. y 1 It '.y ' m r6` [ r' x "'.' . '.T R L t ,„h y Project Description: New Covered Deck Addition to an Existing d �# , .� ��, .a..:..� .. �. Single Family Residence CONNECT NEW DOWNSPOUT DRAMS IMO EXISTING (GIY STORM SEWER) T Vicinity Map fScale: NTS LOT COVERAGE: EXISTING BLDG AREA 1649 SF NEW ADDITION 382 SF TOTAL BLDG AREA 2031 SF LOT AREA 7867 SF LOT COVERAGE 26% TESC NOTES 1. EROSION CONTROLTO BE MAINTAINED WITH THE USE OF A SILT FENCE ALONG THE LOWER GRAVITY LIMITS OF CONSTRUCTION. SILT FENCE IS TO BE ANCHORED IN A TRENCH FILLED WITH ONSITE SOIL. 2, ALL SPOIL SOILS TO BE HAULED OFF SITE. 3. ALL CONSTRUCTION VEHICLE TIRES TO BE (BRUSHED NOT WASHED) FREE OF DEBRIS BEFORE LEAVING THE SITE. 4, THE CONTRACTOR SHALL KEEP OFF-SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. Building Official: City of Anacortes Building Classification: Type V -B (UNSPRINKLERED) Zoning: R2 Title Holder: Karin Kenney 5508 Doon Way Anacortes, Washington 98221 Contact: Steve Moehl / John Moehl ph 360 941 8877 em steve@newcreationsbuilding.com em john@newcreationsbuilding.com Project Location: 5508 Doan Way :.I h t iv1 "Tk1 -W r "lI() iPIP L '. Anacortes, Washington 98221 _ jam�iii Y !{:,'t . ' .. .. _'.a .. ..c ,7 Parcel Number: P131507 Legal Description: Lot 71, Skyline No 7 - Qtr 01, Sct 28, Twn i Project Locationr7 n: Subcontractors Prior To Starting Construction. If Discrepancies Exist Please Contact The Contrac / esi Further lnform 741. tissa SKYLINE � iCR CLL) ^, IT! 1'� 1 Cc W U ' J )III his 1 v ypryf {� R e. i. I III Ih I �9yw{ ✓V 3 I Y+ 1J UJ v oR IJ, Z CONNECT NEW DOWNSPOUT DRAMS IMO EXISTING (GIY STORM SEWER) T Vicinity Map fScale: NTS LOT COVERAGE: EXISTING BLDG AREA 1649 SF NEW ADDITION 382 SF TOTAL BLDG AREA 2031 SF LOT AREA 7867 SF LOT COVERAGE 26% TESC NOTES 1. EROSION CONTROLTO BE MAINTAINED WITH THE USE OF A SILT FENCE ALONG THE LOWER GRAVITY LIMITS OF CONSTRUCTION. SILT FENCE IS TO BE ANCHORED IN A TRENCH FILLED WITH ONSITE SOIL. 2, ALL SPOIL SOILS TO BE HAULED OFF SITE. 3. ALL CONSTRUCTION VEHICLE TIRES TO BE (BRUSHED NOT WASHED) FREE OF DEBRIS BEFORE LEAVING THE SITE. 4, THE CONTRACTOR SHALL KEEP OFF-SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. Building Official: City of Anacortes Building Classification: Type V -B (UNSPRINKLERED) Zoning: R2 Title Holder: Karin Kenney 5508 Doon Way Anacortes, Washington 98221 Contact: Steve Moehl / John Moehl ph 360 941 8877 em steve@newcreationsbuilding.com em john@newcreationsbuilding.com Project Location: 5508 Doan Way Anacortes, Washington 98221 Skagit County Parcel Number: P131507 Legal Description: Lot 71, Skyline No 7 - Qtr 01, Sct 28, Twn 35, Ra 01 Plan Note: Plans Are To Be Reviewed By All Subcontractors Prior To Starting Construction. If Discrepancies Exist Please Contact The Contrac / esi Further lnform 741. eE F r ^, IT! Ln LL Z) 1'� 1 Cc W U ' O z �4 �? 1 v �I' 3 I j � U" lu Li UJ v 4 Z z Q � i r7r.y i 14 z L- C tt^ 0 4 ,. z N a C) CG3 Cir=y) m These plans have been reviewed by the SPOA Architectural Committee for compliance to Skyline Property Owners Association CC&R's only. Property owner is solely responsible for all engineering, code compliance and property boundaries. I f�0 Approved ❑ Approved as Noted f❑ Denied ;; X AC, Member /ate YAC Member D Notes: APR 0 9 2015 Jonathan Richards 5105 Sterling Drive Anacortes, WasNngton 984221 ph 360.391.0832 em lanamvtis9Wglmall<an Project Description: New Covered Deck Addition to an Existing Single Family Residence Plan Information Existing Residence 1289 SF Existing Garage 360 SF New Covered Deck 382 SF Total Building Area 2031 SF Lot 7867 SF OC -4 00a C O O= t o" a m 0 W a O V Llr) a Ln Revisions: Print Date 8/13/14 ndex: :over Page/Site Plan A1.0 'oundafion, Floor, Roof AIA lection, FJevailons A2.1 Al e0 z O O O b z 0 0 0 PIAa I 5� I IF Scale: 1/4" m V z O a a a mI N r El, died Post Bases _ 2x10 PT Rim/LUS2102 Hangers r- 8"Sonotube. 24" Sq Footing r 32'.11/2" ADDITION i Roof Rafters Connected to Sleeper Along Ridge b 0 Note: Extend All Vents Thr, New Roof I) Garage plan Foundation Plan ' 0 2 5 10 Scale: 1/4f'= V 25-0' 10'-103/4" t USE zMAX CONNECTORS AND HOT DIPPED �s C z� GALVANIZED FASTENERS OR EQUIVALENT t s WHEN IN CONTACT WITH TREATED WOOD. 2x10 PT Rim 1` ALTERNATE: PROVIDE 30#ME FELT BETWEEN t TREATED WOOD AND METAL CONNECTIONS. x _- I 6'-0"TYP Dining Kitchen '�, Bathroom 71 b These plans have been reviewed by the SPO Architectural Committee for compliance to Skyline Property Owners Association CCSR's only. Property owner is solely responsible for all engineering, code compliance and prope IDoundaries. f ❑ Approved ❑ Approved as Noted Pian AN, Roof Plan ❑ Denied 1 0 2 5 ,.��W Scale: 1/4"=r AC Member Date t L.o� i AC Member &at f Notes: FINISH GRADE PRESSURE TREATED POST PER PLAN SIMPSON COLUMN BASE PER PLAN — R'SONOTUBE z FOOTING PAD PER PLAN r PER PLAN l24" TYP UNO) Sonotube Exterior Column Support Scale: 1" m 1'-0" JOISTS PER PLP RIM JOI Deck Connection Gable d rc e a 0 O PLAN NOTES: 1. PLANS TO BE REVIEWED BY ALL SUBCONTRACTORS PRIOR TO STARTING CONSTRUCTION. IF DISCREPANCIES EXIST PLEASE CONTACT THE OWNER, GENERAL CONTRACTOR, OR THE DESIGNER FOR FURTHER INFORMATION. 2. ALL NEW CONSTRUCTION TO MATCH EXISTING CONDITIONS. 3. CONFIRM AND BUILD POOL PER SPECIFICATIONS AND REQUIREMENTS FOR CONSTRUCTION. VERIFY WITH CONSTRUCTION PLANS. BEINSTALLED 4X JOIST HANGERS IESSURE TREATED JOISTS @ 16" O.C. ;E TREATED DECK LEDGER JOIST C/W 2 ROWS OF 1/2" x 6" LAG BOLTS @ 16" O.C. STAGGER PLACEMENTS BETWEEN ROWS Scale: 1"= l'-0" 32'-1 1/2" ADDITION drafti 10-83/4" 10'-6" Jonathan Richards _ 4x4 Posts. Simpson ABU44 r El, died Post Bases _ 2x10 PT Rim/LUS2102 Hangers r- 8"Sonotube. 24" Sq Footing r Project Description: New Covered Deck Addition to an Existing Single Family Residence Plan Information: L J 2-0 LTJ fT^ �7 PT_.4x8 Beam I� L" ty� _M7 N N 00 0- -CO I r- I \y2x70 PTRim/W52I OZ Han9ers2xlo Joists@l6"O.C. O� 03 N O W I OU C Q LO E 0 E Optional S i cfio /b"�no. I i 0 Revisions: Print Date 8/13/14 Index: L Foundation, Floor, Roof AM Section, Elevations A2.1 �.� tfJ' \ f L Roof Plan AM J �_ I' pT �4;a I) Garage plan Foundation Plan ' 0 2 5 10 Scale: 1/4f'= V 25-0' 10'-103/4" t USE zMAX CONNECTORS AND HOT DIPPED �s C z� GALVANIZED FASTENERS OR EQUIVALENT t s WHEN IN CONTACT WITH TREATED WOOD. 2x10 PT Rim 1` ALTERNATE: PROVIDE 30#ME FELT BETWEEN t TREATED WOOD AND METAL CONNECTIONS. x _- I 6'-0"TYP Dining Kitchen '�, Bathroom 71 b These plans have been reviewed by the SPO Architectural Committee for compliance to Skyline Property Owners Association CCSR's only. Property owner is solely responsible for all engineering, code compliance and prope IDoundaries. f ❑ Approved ❑ Approved as Noted Pian AN, Roof Plan ❑ Denied 1 0 2 5 ,.��W Scale: 1/4"=r AC Member Date t L.o� i AC Member &at f Notes: FINISH GRADE PRESSURE TREATED POST PER PLAN SIMPSON COLUMN BASE PER PLAN — R'SONOTUBE z FOOTING PAD PER PLAN r PER PLAN l24" TYP UNO) Sonotube Exterior Column Support Scale: 1" m 1'-0" JOISTS PER PLP RIM JOI Deck Connection Gable d rc e a 0 O PLAN NOTES: 1. PLANS TO BE REVIEWED BY ALL SUBCONTRACTORS PRIOR TO STARTING CONSTRUCTION. IF DISCREPANCIES EXIST PLEASE CONTACT THE OWNER, GENERAL CONTRACTOR, OR THE DESIGNER FOR FURTHER INFORMATION. 2. ALL NEW CONSTRUCTION TO MATCH EXISTING CONDITIONS. 3. CONFIRM AND BUILD POOL PER SPECIFICATIONS AND REQUIREMENTS FOR CONSTRUCTION. VERIFY WITH CONSTRUCTION PLANS. BEINSTALLED 4X JOIST HANGERS IESSURE TREATED JOISTS @ 16" O.C. ;E TREATED DECK LEDGER JOIST C/W 2 ROWS OF 1/2" x 6" LAG BOLTS @ 16" O.C. STAGGER PLACEMENTS BETWEEN ROWS Scale: 1"= l'-0" drafti & de LC TN Jonathan Richards 51055terlino Wye Acades. Washington 98221 r ph 360.391.0832 em j,wtie,. swoe,eltmm Project Description: New Covered Deck Addition to an Existing Single Family Residence Plan Information: Existing Residence 1289 SF Existing Garage 360 SF New Covered Deck 382 SF Total Building Area 2031 SF Lot 7867 SF N N 00 0- -CO r- 0 O� 03 N O W I OU C Q LO E 0 E v 0 Revisions: Print Date 8/13/14 Index: Cover Page/Site Plan AID Foundation, Floor, Roof AM Section, Elevations A2.1 Foundation/Framing Plan Floor Plan Roof Plan AM South Elevation 02 I5I 10 u Scale: 1 /4" = 1' North Elevation 0r 2 5 Scale:1/4 J GLAM Per Plan 25" Grade i I I� .I Building Section 0 1 3 5 Scale: 1/2" - 1' Standing Seam Metal Roof or TPO Rafters To Connect 2 Layers 30# Building Paper At Using Ridge 1/7 OSB Rafter Sheathing DBL 2x8 Rafters ® 24" O.C. 12 2xI0 Option 1.5 --- 11 1 I 1 1 1 I 1 1 1 I 1 Jetted Swin Spa On 6"Slab 1 I � I a 1 I Sonctube Footing 2-1 I I NEW DECK ADDITION � F West Elevation 0 2 5 10 Scale: 114'= 1' East Elevation 0 2 5 Scale 10 These plans have been reviewed by the SPOA Architectural Committee for compliance to Skyline Property Owners Association CUR's only. Property owner is solely responsible for all engineering, code compliance and property boundaries. 1 r+Approved ❑ Approved as Noted Denied AC Member Date i AC Member D e 0 ]rafting, ._ _,i" & design -L Jonathan Richards 5105 Stena olive Anacodes. Washington 98331 ph 360.391.0832 eT priapi- lhh nnol— Project Descrlption: New Covered Deck Addition to an Existing Single Family Residence Plan Information Existing Residence 1269 SF Existing Garage 360 SF New Covered Deck 382 SF Total Building Area 2031 SF Lot 7867 SF N N 00 0- C i ^ O O" O Go `o O �a o E `o `u 0 Revisions: Print Date 8/ 13/14 ex: er Page/SRe Plan A1.0 idafion, Floor, Roof A1.1 Ilon, Elevations A2.1 Elevations Building Section A2. ■