Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2022-0345 1504 Latitude Circle
1 C} City of Anacortes Invoice/Permit#: BLD-2022-0345 904 6th Street Applied date: 05/11/2022 P.O.Box 547 Issue date: 05/11/2022 _� t►�: Anacortes, WA 98221-0547 Expire date: 11/07/2023 (360) 293-1901 Job Address: 1504 LATITUDE CIR Permit Type: Mechanical Permit ANACORTES WA 98221 Project: APN: Remarks: Instal two heat pumps. Owner: ANDREW OLSEN Contractor: WESTERN SOLAR INC. Address: 1504 LATITUDE CIR Address: 4041 HOME RD ANACORTES WA 98221 BELLINGHAM WA 98226-9158 Phone: (425)301-6150 Phone: (360)746-0859 License#: General Information: Fees: #of Heat Pumps<= 3 Hp 2 Mechanical Permit Fees 52.90 Total Calculated: 52.90 Deposits/Receipts: 0.00 Total Due: 52.90 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. At' x SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY 1T y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 PLUMBING & MECHANICAL PERMIT APPLICATION Please complete all applicable information and submit to buildingpermit@citygfanacortes.org PROPERTY INFORMATION PROJECT ADDRESS ASSESSORS PARCEL NUMBER 1504 Latitude Circle, Anacortes WA 98221 P133668 PROJECT VALUATION $18,433.57 ❑X RESIDENTIAL COMMERCIAL PROPERTY OWNER OWNER PHONE Andrew Olsen 425-301-6150 OWNER ADDRESS OWNER EMAIL 1504 Latitude Circle, Anacortes WA 98221 andrew.r.olsen@hotmail.com APPLICANT INFORMATION [:]PROPERTY OWNER CONTRACTOR OTHER: NAME PHONE Western Solar/ Lindsay Sikich 360-746-0859 ADDRESS EMAIL 4041 Home Road, Ste A Bellingham,98226 info@westernsolarinc.com CONTRACTOR INFORMATION NAME PHONE Western Solar Inc. 360-746-0859 CONTRACTOR'S BUSINESS LICENSES* STATE LICENSE# EXPIRATION *All Contractors & Subcontractors must have a valid ECWESTES*872DD 3/8/2023 City of Anacortes business license prior to doing work UBI LICENSE# EXPIRATION in the City. 602258981 5/31/2022 ADDRESS(STREET,CITY,STATE,ZIP) EMAIL 4041 Home Road, Ste A Bellingham,98226 info@westernsolarinc.com PROJECT INFORMATION DESCRIPTION OF PROPOSED WORK: Install DHP(S) IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? YES ❑X NO If YES, provide the permit/application number. Plumbing/Mechanical Permit Application Updated December 2021 Page 1 of 3 MECHANICAL , APPLIANCE/EQUIPMENT INFORMATION (NEW AND RELOCATED) EQUIPMENT TYPE Indicate the number of fixtures for each equipment type TOTAL GAS ELECTRIC OTHER-Please specify COMMENT, Furnace Wall Heater Water Heater Heat Pump 2 2 Air Conditioner/Handler Radiant/Hydronic Heating Exhaust Fans Range Hood Fireplace Clothes Dryer&Duct Stove/Range/Oven Refrigeration Unit Gas Piping/Outlet(s) Boiler BTUs: Other TOTAL MECHANICAL OUTLETS, P LUMBING FIXTURES FIXTURE TYPE(NEW AND RELOCATED) TOTAL FIXTURE TYPE(NEW AND RELOCATED) TOTAL Toilets Refrigerator water supply Kitchen Sink Pressure Reduction Valve/Regulator Utility Sink ater Service Line Tub Water Piping Hand Sink Washing Machine Shower Electric Water Heater:Tank-less? Yes❑ No Dishwasher Backflow Prevention Device Urinal Hose Bib Floor Drain/Floor Sink Drinking Fountain Hydronic Heat in: Floor Wall rease Interceptor Other-pleose specify: TOTAL PLUMBING FIXTURES . Plumbing/Mechanical Permit Application Updated December 2021 Page 2 of 3 PLUMBING & MECHANICAL PERMIT APPLICATION CHECKLIST COMMERCIAL RESIDENTIAL 9 v K -a r) ell a SUBMITTAL REQUIREMENTS a 3 a 3 n Z Z Z rr��f W m D Gf D G) H r r m FVI Plumbing & Mechanical Permit Application ✓ ✓ ✓ ✓ N/A Mechanical Plans ✓ N/A Structural Calculations ✓ N/A State Non-Residential Energy Code Compliance Form ✓ Manufacturer's Specifications/CutSheets ✓ ✓ ✓ N/A Plumbing Plans ✓ N/A Listed&Tested Fire Stopping Assemblies ✓ N/A Elevation View for Roof Mounted Equipment ✓ ✓ N/A Existing Floor Plan ✓ ✓ ✓ ✓ N/A New Floor Plan ✓ ✓ ✓ ✓ NOTE: 1. Handouts and standard details may be found on the City's Planning, Community, & Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, & reports prepared by state licensed architects or professional engineers must be stomped and signed by the design professional. 3. If installing a backflow prevention device, it will need to pass test results of which will need to be submitted to the city for review. ACKNOWLEDGEMENTS & SIGNATURE By affixing my signature hereto,I certify that I am the owner,or am acting as the Owner's authorized agent, and that the application and documents contained with this submittal are complete and accurate to the best of my knowledge and abilities. 519 22 SIGNATURE DATE Plumbing/Mechanical Permit Application Updated December 2021 Page 3 of 3 SUBMITTAL DATA: 1 1 ' M-SERIES MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM AWlk ELECTRIC Job Name: System Reference: Date: � ��liolllllllllllllllluum�,, �� dlllllllllllllllllllllllllllllllllllllli'' 5 02 �� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII� �� iIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIP'11 W�� ,I C O Outdoor Unit:MXZ-3C24NA ACCESSORIES ❑ 3/8"x 1/2"Port Adapter(MAC-A454JP-E) ❑ 1/2"x 3/8"Port Adapter(MAC-A455JP-E) ❑ 1/2"x 5/8"Port Adapter(MAC-A456JP-E) ❑ 1/4"x 3/8"Port Adapter(PAC-493PI) ❑ 3/8"x 5/8"Port Adapter(PAC-SG76RJ-E) ❑ M-NET Adapter(PAC-I FO 1 MNT-E) ❑ Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C30NA2 Rated Capacity Btu/h 28,400/27,400 Cooling* Capacity Range Btu/h 12,600-28,400/12,600-27,400 (Non-ducted/Ducted) Rated Total Input W 2,680/2,860 Rated Capacity Btu/h 28,600/27,600 Heating at tod/Du 4/Ducted)(Non-ducted Capacity Range Btu/h 11,400-36,000/11,400-35,000 Rated Total Input W 2,150/2,220 Heating at 17°F* Rated Capacity Btu/h 16,000/15,100 (Non-ducted/Ducted) Rated Total Input W 2,120/2,140 Power Supply Voltage,Phase, Hertz 208/230V, 1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Sound Pressure Level Cooling dB(A) 52 Heating 56 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 137(62) External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(12.7) Eight Ports [Gas(Low Pressure) A: 1/2(6.35); B,C:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared Refrigerant R41 OA *Rating Conditions per AHRI Standard: Cooling I Indoor:80'F(270 C)DB/67'F(190 C)WB Heating at 47T I Indoor:70'F(21°C)DB/60'F(16*C)WB Heating at 17'F I Indoor:70'F(21°C)DB Cooling I Outdoor:950 F(350 C)DB/23.9°C(75'F)WB Heating at 47OF I Outdoor:470 F(80 C)DB/430 F(60 C)WB Heating at 170 F I Outdoor:170 F(-8°C)DB/150 F(-9°C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: 1 • • OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F @ 17°F Cooling 14 to 115'F(-10 to 46°C)DB Non-ducted Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) 19.0 10.6 10.6 3.90 2.77 Ducted and 17.6 10.1 10.1 3.77 2.78 Non-ducted Ducted 16.2 9.6 9.6 3.64 2.78 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C30NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. OPERATIONAL - DUCTED: Operational CoolingCapacity IndoorPerformance for Power Usage Range Current(208/23OV) Unit Combinations Unit A Unit B Unit C (W) 9 9000 0 0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 24000 0 0 26000 0 0 9+9 9000 9000 0 10900 10900 0 9+ 12 9000 12000 0 10500 14000 0 9+15 9000 15000 0 10200 17000 0 9+18 8733 17467 0 9133 18267 0 9+24 7418 19782 0 7473 19927 0 12+ 12 12000 12000 0 13600 13600 0 12+ 15 11644 14556 0 12178 15222 0 TBD 12+ 18 10880 16320 0 10960 16440 0 12+24 9067 18133 0 9133 18267 0 15+ 15 13600 13600 0 13700 13700 0 15+ 18 12364 14836 0 12455 14945 0 18+ 18 13600 13600 0 13700 13700 0 9+9+9 9000 9000 9000 9133 9133 9133 9+9+ 12 8220 8220 10960 8280 8280 11040 9+9+ 15 7582 7582 12636 7582 7582 12636 9+9+ 18 7050 7050 14100 7000 7000 14000 9+12+12 7582 10109 10109 7582 10109 10109 9+12+15 7050 9400 11750 7000 9333 11667 12+ 12+ 12 9400 9400 9400 9333 9333 9333 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. OPERATIONAL PERFORM NON-DUCTED: Operational CoolingCapacity IndoorPerformance for Power Unit Combinations Unit A Unit B Unit C (W) 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 22500 0 0 27600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+12 6000 12000 0 7333 14667 0 6+15 5714 14286 0 7257 18143 0 6+18 5750 17250 0 6900 20700 0 6+24 5440 21760 0 5520 22080 0 9+9 9000 9000 0 11000 11000 0 9+12 8571 11429 0 10886 14514 0 9+15 8625 14375 0 10350 17250 0 TBD 9+18 8600 17200 0 9200 18400 0 9+24 7418 19782 0 7527 20073 0 12+ 12 11500 11500 0 13800 13800 0 12+ 15 11467 14333 0 12267 15333 0 12+ 18 10880 16320 0 11040 16560 0 12+24 9067 18133 0 9200 18400 0 15+ 15 13600 13600 0 13800 13800 0 15+ 18 12364 14836 0 12545 15055 0 18+ 18 13600 13600 0 13800 13800 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7371 7371 11057 6+6+ 12 6000 6000 12000 7100 7100 14200 6+6+ 15 5778 5778 14444 6311 6311 15778 6+6+ 18 5680 5680 17040 5720 5720 17160 6+6+24 5000 5000 20000 5000 5000 20000 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. OPERATIONAL PERFORM NON-DUCTED: Operational CoolingCapacity IndoorPerformance for Power is O Unit Combinations Unit A Unit B Unit C (W) 6+9+9 6000 9000 9000 7100 10650 10650 6+9+ 12 5778 8667 11556 6311 9467 12622 6+9+ 15 5680 8520 14200 5720 8580 14300 6+9+ 18 5382 8073 16145 5382 8073 16145 6+12+12 5680 11360 11360 5720 11440 11440 6+ 12+ 15 5382 10764 13455 5382 10764 13455 6+ 12+ 18 5000 10000 15000 5000 10000 15000 5000 12500 12500 6+15+15 TBD 5000 12500 12500 9+9+9 8667 8667 8667 9467 9467 9467 9+9+ 12 8520 8520 11360 8580 8580 11440 9+9+ 15 8073 8073 13455 8073 8073 13455 9+9+ 18 7500 7500 15000 7500 7500 15000 9+ 12+ 12 8073 10764 10764 8073 10764 10764 9+12+ 15 7500 10000 12500 7500 10000 12500 12+ 12+ 12 10000 10000 10000 10000 10000 10000 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8' n R-Air V foke 2-13/16" 9-1/16' 4-19/32" 2-1/32" 3-1/16' 2-U Shaped Notched Hole 13/32"T-- ri (Foundation Bolt 1110) ri ZD Sid.Air Intake b m 6-01-5/16'Drain Hole N 13/32' b o s�hnrge 13/tz 2-(15/32"x1-13/32")Oval Hole 1-1/32" 2-07/8'knockout hole (Foundation Bolt M10) 1-1/2' 1 ...ctin wire hole) 1-5/8' 37-13/32' 31/32' 13" 19/32" 3-m7/8'punched hole (Connecting wire hole) Hnne(e � \ Hnntlle Ol PV Hantlle Hontlle O 2-3/4" O® Air Intake �® GAS}Unif C Lla 1/L'(06.351PLARE O® GAS}Unif g GAS 3/1109.521FLARE O® U. 1 Lla 1/L'(06.35)FLARE ,fLJU�J IrtlPBq• GA5}Uni)A— GAS 1/2'(012.])FLARE v1-11131 14-7/32' 1.FREE SPACE E E E 3-15/16" or more 8 0 777T7 3-15/16' or more r,325,32' or more Conduit plates 2.SERVICE SPACE v Conduit connector E L Lock nut 3-15116" or more SERVICE SPACE 13-25/32' or more 13-25/32' or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com c ETA us FORM#MXZ-31330NA2 for Multiple Indoor Unit Styles-201605 Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MSZ-FS09NA ; MUZ-FS09NAH 9,000 DELUXE WALL MOUNT 9,000 BTUIH HYPER-HEATING OUTDOOR UNIT W/BASE PAN HEATER AAk ELECTRIC Job Name: System Reference: Date: Indoor Unit.. MSZ-FS09NA ........................................................... Outdoor Unit MUZ-FS09NAH mime= _- GAT y N's �Y�IIIIIIIIII�IIII�IIIIII�IIVVYos� �M _,5 02 AaF $nlIlllllllllllllllllllllllllllllllllll�n 4coy- w 'illllllllllllllllllllllllllllllll� ''�oIIIIIIIIIIIIDii� . INDOOR UNIT FEATURES • Slim wall-mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger,vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • 3D i-see Sensor"enables advance features: o Indirect or Direct Airflow for personalized comfort o Absence Detection for energy-saving mode • Double Vane features: o Separates airflow to deliver air across a large area o Simultaneously deliver to air separate sections of a room o Generates more comfortable natural airflow pattern • Multiple control options available: o Back-lit screen handheld remote controller(provided with unit) o kumo cloud°smart device app for remote access o Third-party interface options o Wired or wireless controllers • Triple-action Filtration:Nano Platinum Filter,Deodorizing Filter,&Electrostatic Anti-Allergy Enzyme Filter • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns OUTDOOR UNIT FEATURES • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • H2i plusTM performance offers 100%heating capacity at-50 and 70%to 81%heating capacity at-130 F • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life • Built-in base pan heater Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 ' Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 9,000 Minimum Capacity BTU/H 1,700 Cooling at 95°F' Maximum Power Input W 1,000 Rated Power Input W 560 Moisture Removal Pints/h 0.6 Sensible Heat Factor 0.92 Power Factor % 89.0/90.0 Maximum Capacity BTU/H 18,000 Rated Capacity BTU/H 9,600 Minimum Capacity BTU/H 1,600 Heating at 47°F Maximum Power Input W 1,740 Rated Power Input W 620 Power Factor % 92.0/92.0 Maximum Capacity BTU/H 14,170 Heating at 17°F3 Rated Capacity BTU/H 5,900 Maximum Power Input W 1,710 Rated Power Input W 580 Maximum Capacity BTU/H 11,590 Heating at 5°F" Maximum Power Input W 1,540 Heating at-5°FB Maximum Capacity BTU/H 9,600 Heating at-13°F7 Maximum Capacity BTU/H 8,000 SEER 30.5 EER' 16.05 HSPF[IV] 12.5 COP at 47°F2 4.54 Efficiency COP at 17°F at Maximum Capacity3 2.43 COP at 5°F at Maximum Capacity° 2.21 COP at-5°F at Maximum Capacitye 2.0 COP at-13°F at Maximum Capacity' 1.71 ENERGY STAR®Certified Yes Voltage,Phase,Frequency 208/230,1,60 Guaranteed Voltage Range VAC 187-253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating[SCCR] kA 5 Recommended Fuse/Breaker Size(Oudoor) A 15 Recommended Wire Size[Indoor-Outdoor] AWG 14 MCA A 1.0 Fan Motor Full Load Amperage A 0.65 Fan Motor Output W 40 Airflow Rate at Cooling,Dry CFM 137-167-221-304-381 Airflow Rate at Cooling,Wet CFM 117-143-190-261-328 Airflow Rate at Heating,Dry CFM 140-167-225-325-437 Sound Pressure Level[Cooling] dB[A] 20-23-29-36-40 Indoor Unit Sound Pressure Level[Heating] dB[A] 20-24-29-39-42 Drain Pipe Size In.[mm] 5/8[15.88] Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W x D x H:In.[mm] 36-7/16 x 9-3/16 x 12(+11/16)[925 x 234 x 305(+17)] Package Dimensions W x D x H:In.[mm] 39 x 12-1/4 x 15-1/2[990 x 310 x 400] Unit Weight Lbs.[kg] 29[13.5] Package Weight Lbs.[kg] 34[15.4] Indoor Unit Operating Temperature Cooling Intake Air Temp[Maximum/Minimum]* °F 90 DB, 73 WB/67 DB, 57 WB Range Heating Intake Air Temp[Maximum/Minimum] °F 80 DB/70 DB NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F(Indoor H Outdoor) °F 70 DB,60 WB H 47 DB,43 WB 3Heating at 17°F(Indoor H Outdoor) °F 70 DB,60 WB//17 DB,15 WB Conditions °Heating at 5°F(Indoor H Outdoor) °F 70 DB,60 WB//5 DB,4 WB 'Heating at-4°F(Indoor H Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB 'Heating at-5°F(Indoor H Outdoor) °F 70 DB,60 WB//-5 DB,-6 WB 7Heating at-13°F(Indoor H Outdoor) °F 70 DB,60 WB//-13 DB,-14 WB *Outdoor Unit Operating Temperature Range(Cooling Air Temp(Maximum/Minimum)): Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. •For P-Series only: » Wind baffles required to operate below 23°F DB in cooling mode. • Cooling-only system with wind baffle:-40°F-115°F. n Heat pump system with wind baffle:O°F-115°F. • Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range(Cooling Thermal Lock-out/Re-start Temperatures;Heating Thermal Lock-out/Re-start Temperatures): •System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION(ONLY APPLIES TO P-SERIES-BS MODELS) External Outer Panel:Phosphate coating+Acrylic-Enamel coating Fan Motor Support:Epoxy resin coating(at edge face) •Separator Assembly Valve Bed:Epoxy resin coating(at edge face) Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 ' MCA A 10.0 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 114111183 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level,Cooling' dB(A) 48 Sound Pressure Level,Heating2 dB(A) 49 Outdoor Unit Compressor Type Twin Rotary Compressor Model SNB092FQAMT Compressor Rated Load Amps A 9.2 Compressor Locked Rotor Amps A 7.4 Compressor Oil Type//Charge oz. FV50S//0.35 External Finish Color Munsell 3Y 7.8/1.1 Base Pan Heater Built-in Unit Dimensions W x D x H:In.[mm] 31-1/2 x 11-1/4 x 21-5/8[800 x 285 x 550] Package Dimensions W x D x H:In.[mm] 37 x 15 x 24-1/2[940 x 380 x 630] Unit Weight Lbs.[kg] 83[37.5] Package Weight Lbs.[kg] 89[40] Cooling Air Temp[Maximum/Minimum]* *F 115 DB/14 DB Outdoor Unit Operating Temperature Cooling Thermal Lock-out/Re-start Temperatures** °F -4/0 Range Heating Air Temp[Maximum/Minimum] °F 75 DB,65 WB/-13 DB,-14 WB Heating Thermal Lock-out/Re-start Temperatures** °F -18/-14 Type R410A Charge Lbs,oz 2,9 Refrigerant Chargeless Piping Length Ft.[m] 25[7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft.[g/m] 0.216[20] Gas Pipe Size O.D.[Flared] In.[mm] 3/8[9.52] Liquid Pipe Size O.D.[Flared] In.[mm] 1/4[6.35] Piping Maximum Piping Length Ft.[m] 65[20] Maximum Height Difference Ft.[m] 40[12] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 'Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB 'Heating at 17*F(Indoor//Outdoor) *F 70 DB,60 WB//17 DB,15 WB Conditions °Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB sHeating at-4°F(Indoor//Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB 'Heating at-5*F(Indoor//Outdoor) °F 70 DB,60 WB//-5 DB,-6 WB 7Heating at-13*F(Indoor//Outdoor) °F 70 DB,60 WB//-13 DB,-14 WB *Outdoor Unit Operating Temperature Range(Cooling Air Temp(Maximum/Minimum)): Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. For P-Series only: • Wind baffles required to operate below 230F DB in cooling mode. • Cooling-only system with wind baffle:-40'F-115*F. • Heat pump system with wind baffle:O°F-115`F. • Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range(Cooling Thermal Lock-out/Re-start Temperatures;Heating Thermal Lock-out/Re-start Temperatures): •System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION(ONLY APPLIES TO P-SERIES-BS MODELS) •External Outer Panel:Phosphate coating+Acrylic-Enamel coating Fan Motor Support:Epoxy resin coating(at edge face) Separator Assembly Valve Bed:Epoxy resin coating(at edge face) •Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR CN24 Relay Kit ❑ CN24RELAY-KIT-CM3 System Control Interface MAC-3341F-E BACnet®and Modbus Interface PAC-UKPRC001-CN-1 Thermostat Interface PAC-US444CN-1 Control Interface Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 kumo station®for kumo cloud® PAC-WHS01 HC-E IT Extender PAC-WHS011E-E Lockdown bracket for remote controller RCMKP1CB Remote Sensor Wired Remote Sensor M21 EAA307 Wireless temperature and humility sensor for kumo cloud® PAC-USWHS003-TH-1 Simple MA Remote Controllert PAC-YT53CRAU-J Wired Remote Controller Deluxe Wired MA Remote Controllert PAR40MAAU Touch MA Controllert PAR-CT01 MAU-SB Wireless Remote Controller kumo touch'RedLINK'Wireless Controller MHK2 Blue Diamond Sensor Extension Cable—15 Ft. C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps C21-014 Condensate Sauermann Condensate Pump S130-230 Drain Pan Level Sensor/Control SS610E Fascia Kit for MicroBlue Pump,mounts the MicroBlue and sensor directly beneath indoor unit T18-016 Blue Diamond(MicroBlue)Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H X85-003 Disconnect Switch (30A/600V/UL)[fits 2"X 4"utility box]-Black TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White TAZ-MS303W Filter Electro Static Anti-allergy Enzyme Filter MAC-2330FT-E Platinum Deodorizing Filter MAC-300OFT-E 15'x 114"x 15'/3/8"Lineset(Twin-Tube Insulation) MLS143812T-15 Lineset 30'x 1/4"x 30'/3/8"Lineset(Twin-Tube Insulation) MLS143812T-30 50'x 1/4"x 50'/3/8"Lineset(Twin-Tube Insulation) MLS143812T-50 65'x 1/4"x 65'/3/8"Lineset(Twin-Tube Insulation) MLS143812T-65 NOTES: tRequires MAC-3341F-E •M-Series EZ FIT®Recessed Ceiling Cassette,Floor-mount and Wall-mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller *PAC-SF40RM-E(Unable to use with wireless remote controller) M-Series Ceiling Cassette,Ceiling Suspended,Horizontal-ducted and Multi-position Air Handler P-Series Ceiling Cassette,Ceiling Suspended,Horizontal-ducted and Multi-position Air Handler Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT ACCESSORIES: MUZ-FS09NAH Air Outlet Guide Air Outlet Guide ❑ MAC-881SG Drain Socket Drain Socket MAC-811 DS Hail Guards Hail Guard HG-B4 14 Gauge,4 wire MiniSplit Cable-250 ft.roll S144-250 Mini-Split Wire 14 Gauge,4 wire MiniSplit Cable-50 ft.roll S144-50 16 Gauge,4 wire MiniSplit Cable-250 ft.roll _ S164-250 16 Gauge,4 wire MiniSplit Cable-50 ft.roll S164-50 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic DSD-400P Condensing Unit Mounting Pad:16"x 36"x 3" ULTRILITE1 Outdoor Unit Stand—12"High QSMS1201 M 18"Single Fan Stand QSMS1801 M Stand 24"Single Fan Stand QSMS2401 M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket-Stainless Steel Finish QSWBSS Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. INDOOR UNIT DIMENSIONS: I ' Unit: inch 7/16 x 1-1/16 Oblon hole 7/16 x 13/16 Oblong hole Installation lafe 4-1/16 8-7/8 8-7/8 4-1/16 aO 36-7/16 35-5/8 3/8 8-1/8 -3/ aO M Indoor unif 2-5/8 15-9/16 14-11/16 3-9/16 9 3/16 Air In Wall hole 03 3/I6 Installation plafe Pi in - M 2 19/16 \ 2 - Drain hose M 2-3/8 27-11/16 6-5/16 4 ti 2-3/� _�� II/16 Air ouf 4-5/8 5-3/I6 � N 2 5/8 2-11/I6 (06/09/12 KBTU/H) (15/18 KBTU/H) Insulation 01-7/16 03 Insulation 01-7/16 O.D Liquid line 4114 19-11/16 (Flared connection 4114) d Li uid line 01/4 19-11/16 (Flared connection 4114) Gas line 43/8 16-15/16 (Flared connection 43/8) Gas line 0318 16-15/16 (Flared connection 0112) Drain hose lln5ulafion 41-1/8 Connected pari 05/8 O.D Drain hose Insulafion 01-1/8 Connected parf 45/8 0.1) Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OUTDOOR UNIT DIMENSIONS: 19 Unit: inch REQUIRED SPACE *1 4 in. (100 mm) or more when front and sides of the unit are clear U 100 e 4 0'(10 A 0 o�0< 15-3/4 v Air in Drain hale 01-21/32(MUZ-FS06109112NA) M n Drain hale 01-5/16(MUZ-FS06109112NAH) Air in ' 0 L o m O�n l2oCe 2 01, o 00 N m C � *2 When any 2 sides of left, right 1-9/16 and rear of the unit are clear Air our 2 x hole 3/8 x 13/16 Service ponel. 7/8 11/16 Handle Liquid refrigerant pipe joint Refrigerant pipe(flared)o 114 r un L m rn Gas refrigerant pipe joint N N N gerant pipe(flared)0318 N ' ' �'u m ui rn N rn m oil _ +a 11-29/32 5-11/32 -15/1 19-11/16 6-23/32 Bolt pitch for installation 31-1/2 2-3/4 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvae.com AT ONUB FORM#MSZ-FS09NA-U1 &MUZ-FS09NAH-U1-202101 Intertek Specifications are subject to change without notice. ©2021 Mitsubishi Electric Tirane HVAC US LLC.All rights reserved.