HomeMy WebLinkAboutPermit File BLD-2019-0511 1715 O Avenue (29)MATERIALS TESTING & CONSULTING, INC. Fidalgo Flats - 20B301 - Field Report: Reinforcing Steel: Report #F254463 CLIENT Madrona Real Estate Investors VIII, LLC DATE 04/27/2021 PROJECT LOCATION 1715 O Avenue Anacortes WA 98221 PERMIT # BLD-2019-0511 Inspection Information: Inspection Date: Time Onsite: 10:23 Weather 04/27/2021 am Conditions: Inspection Performed: Reinforcing Steel Report Profile: ® Needs Engineer's Approval ® Approved by Engineer Mostly cloudy ® Retest / Re -inspection (1 Hours) Subcontractor: Continuous or Periodic: Periodic Sheets: S2.1, S3.0, S3.1 Location/Area: Stem walls gl (A-D/1-6) Details: Per the noted sheets above and notes below Level/Elevation: Foundation Reinforcing Grade: ASTM 615 Grade 60 Embeds: N/A Reference Reports: F254380 Approved Plans Dated: 11/16/2021 Remarks: MTC on site as requested to visually inspect reinforcing steel at the following location(s): 1.) MTC observed the completion of the reinforcing steel for the building foundation stem walls at grid lines (A-D/1-6). MTC observed that the walls were inspected per plan sheet S2.1 and the typical details called out. -Reinforcing Steel Inspection: 1.) MTC visually inspected the reinforcing steel at the locations noted that the reinforcing steel complied with the approved project plans and specifications. MTC observed the reinforcing steel size, grade, type, and placement. Deficiencies cleared: -At multiple locations, MTC noted the vertical reinforcing was not centered in the wall. The contractor is asking for engineer approval for this condition - The engineer of record accepted the misaligned reinforcing steel as long as a minimum 1-1/2" clearance is maintained. MTC verified the 1-1/2" clearance. -The corner bars at the wall intersections are specified to alternate directions.- MTC verified that the contractor moved the corner bars at intersections to alternating. -The diagonal bar at the step footings was not in place. - MTC verified diagonal bars were in place at the step footings. -The 180-degree hook bar was not in place at the wall ends. - MTC verified the 180-degree hooks at the ends of walls. -Wood spacers were being removed from the bottom of the wall at this time. - MTC verified wood spacers and debris were removed from the forms. This clears the deficiencies noted on report #F254380. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing Burlington101ympialBellinghamlSilverdale ITukwila 3 60.75 5.1990 www.mtc-inc.net Fidalgo Flats - 20B301, 0412712021, #F254463, Page 1 of 3 ahz&UA&L" MATERIALS TESTING & CONSULTING, INC. To the best of MTC inspector's knowledge, the above -described work was performed in general accordance with project specifications and approved plans. Images: UPLOADED: 04/27/2021 10:34:15 UPLOADED: 04/27/2021 10:34:17 UPLOADED: 04/27/2021 10:46:16 UPLOADED: 04/27/2021 10:46:19 UPLOADED: 04/27/2021 10:47:11 UPLOADED: 04/27/2021 10:47:13 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing Burlington IOlympia lBellinghamlSiIverdaleITukwila 360.755.1990 www.mtc-inc.net Fidalgo Flats - 20B301, 0412712021, #F254463, Page 2 of 3 MATERIALS TESTING & CONSULTING, INC. REPORTED BY: Kevin Walters REVIEWED BY: Robert McNamara, Project Manager As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing BurlingtonjOlympia 1BellinghamlSilverdaleITukwila 3 60.75 5.19 90 www.mtc-inc.net Fidalgo Flats - 2013301, 0412712021, #F254463, Page 3 of 3