Fidalgo Flats - 20B301 - Field Report: Reinforcing Steel: Report #F248889
CLIENT Madrona Real Estate Investors VIII, LLC DATE 02/11/2021
PROJECT LOCATION 1715 O Avenue Anacortes WA 98221 PERMIT # BLD-2019-0511
Inspection Information:
Inspection Date: Time Onsite: 8:00 Weather Overcast 30s
02/11/2021 am Conditions:
Inspection Performed: Reinforcing Steel
Report Profile:
® Any Deficiencies Noted E Retest / Re -inspection (1 Hours)
Subcontractor: Continuous or Periodic: jPeriodic
Sheets: S2.0/S2.1
Location/Area: lBasement Walls (A-C/3-5)
Details: 8/S3.1 Level/Elevation: Basement walls
Reinforcing Grade: I Embeds:
Reference Reports: NA Approved Plans Dated: 11/16/2020
Remarks:
MTC was on -site to verify the installation of the hold downs at the top of the basement walls. Hold downs were in place
in accordance with plan sheets and detail 8 on sheet S3.1. Rods were embedded 30" minimum with plate washer and
heavy hex nuts on the end.
One exception noted below:
-The hold down at gl (A/5) was a 3/4" diameter and was called out to be 7/8". The hold down directly north was a 7/8" rod
and was called out to be 3/4". These rods need to be swapped. MTC will verify correction prior to placement of concrete.
Contractor was notified of the issue.
Work in progress. Additional inspection needed.
Images:
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval.
Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing
BurlingtonjOlympialBellinghamlSilverdale ITukwila
3 60.75 5.1990
www.mtc-inc.net
Fidalgo Flats - 20B301, 0211112021, #F248889, Page 1 of 2
aakul��
MATERIALS TESTING & CONSULTING, INC.
A --
UPLOADED: 02/11/2021 11:21:10 G1(A/5)
UPLOADED: 02/11/2021 11:21:12
REPORTED BY: Kevin Walters REVIEWED BY: Robert McNamara, Project Manager
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval.
Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing
BurlingtonjOlympia 1BellinghamlSilverdaleITukwila
3 60.75 5.19 90
www.mtc-inc.net
Fidalgo Flats - 20B301, 0211112021, #F248889, Page 2 of 2