HomeMy WebLinkAboutPermit File BLD-2019-0511 1715 O Avenue (11)MATERIALS TESTING & CONSULTING, INC. Fidalgo Flats - 20B301 - Field Report: Reinforcing Steel: Report #F248889 CLIENT Madrona Real Estate Investors VIII, LLC DATE 02/11/2021 PROJECT LOCATION 1715 O Avenue Anacortes WA 98221 PERMIT # BLD-2019-0511 Inspection Information: Inspection Date: Time Onsite: 8:00 Weather Overcast 30s 02/11/2021 am Conditions: Inspection Performed: Reinforcing Steel Report Profile: ® Any Deficiencies Noted E Retest / Re -inspection (1 Hours) Subcontractor: Continuous or Periodic: jPeriodic Sheets: S2.0/S2.1 Location/Area: lBasement Walls (A-C/3-5) Details: 8/S3.1 Level/Elevation: Basement walls Reinforcing Grade: I Embeds: Reference Reports: NA Approved Plans Dated: 11/16/2020 Remarks: MTC was on -site to verify the installation of the hold downs at the top of the basement walls. Hold downs were in place in accordance with plan sheets and detail 8 on sheet S3.1. Rods were embedded 30" minimum with plate washer and heavy hex nuts on the end. One exception noted below: -The hold down at gl (A/5) was a 3/4" diameter and was called out to be 7/8". The hold down directly north was a 7/8" rod and was called out to be 3/4". These rods need to be swapped. MTC will verify correction prior to placement of concrete. Contractor was notified of the issue. Work in progress. Additional inspection needed. Images: As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing BurlingtonjOlympialBellinghamlSilverdale ITukwila 3 60.75 5.1990 www.mtc-inc.net Fidalgo Flats - 20B301, 0211112021, #F248889, Page 1 of 2 aakul�� MATERIALS TESTING & CONSULTING, INC. A -- UPLOADED: 02/11/2021 11:21:10 G1(A/5) UPLOADED: 02/11/2021 11:21:12 REPORTED BY: Kevin Walters REVIEWED BY: Robert McNamara, Project Manager As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Environmental • Geotechnical Engineering • Special Inspection • Non -Destructive Testing • Materials Testing BurlingtonjOlympia 1BellinghamlSilverdaleITukwila 3 60.75 5.19 90 www.mtc-inc.net Fidalgo Flats - 20B301, 0211112021, #F248889, Page 2 of 2