HomeMy WebLinkAboutPermit File BLD-2022-0491 3916 S Avenue C.i City of Anacortes Invoice/Permit#: BLD-2022-0491 ` 904 6th Street Applied date: 06/22/2022 P.O.Box 547 Issue date: 06/22/2022 Anacortes, WA 98221-0547 Expire date: 12/19/2023 1360) 293-1901 Job Address: 3916 S AVE Permit Type: PV Solar Permit ANACORTES WA 98221-3647 Project: APN: P58856 Remarks: Install 28 solar modules in two arrays on roof top. *"*" * *Contractor will need a City of Anacortes business license endorsement prior to work Owner: STUART&ANGELA CURRIE Contractor: BANNER ELECTRIC INC. DBA BANNER POWER S Address: 3916 SAVE Address: 130 E HAZEL AVE ANACORTES WA 98221-3647 BURLINGTON WA 98233 Phone: (360)941-1789 Phone: (360) 770-2185 .License#: General Information: Fees: Building Valuation 4662 Building Permit Fee 111.25 Plan Review Fee 72.31 State Building Code Fee Resi 6.50 Total Calculated: 190.06 Deposits/Receipts: 0.00 Total Due: 190.06 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law,or of any order, proclamation,guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examin is apple ation and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 c�oR Office Location: 904 61h Street, Anacortes WA 98821 Phone: (360) 293-1901 RESIDENTIAL BUILDING PERMIT APPLICATION THIS APPLICATION PACKET IS USED FOR THE FOLLOWING PROJECT TYPES: Single-Family Residences (SFR), Duplexes, Additions & Remodels, Accessory Structures (i.e. garages, carports), Accessory Dwelling Units, Manufactured Homes, Residential Decks & Retaining Walls, and Docks& Pilings. FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY INFORMATION PROJECT ADDRESS(STREET,SUITE#) ASSESSOR PARCEL NUMBER 3916 S AVE P58856 SUBDIVISION/LOT# ZONING LOT AREA(SIZE) 9,147 R2A SQ. FT. TYPE OF PROJECT NEW ADDITION REPAIR REMODEL CHANGE OF USE SFR Lj Duplex ❑Deck/Porch Accessory Dwelling Unit: ❑Detached ❑Attached ❑Retaining Wall ❑ Manufactured Home ❑Accessory Structure ❑ Shoreline Structure(dock, pilings,floats etc.) * ❑X Other: Roof mounted solar *If application is for a shoreline structure, please complete the Shoreline Structure Checklist. IS THIS WORK ASSOCIATED WITH ANOTHER PROJECT? I YES ✓ NO f YES, provide the permit/application number: PROJECT SUMMARY: PROJECT VALUATION Installation of 28 solar modules on west and east facing roof (Cost of Materials & Labor) planes $4,662 PROPERTY OWNER INFORMATION NAME PHONE Currie, Angela, J (360)914-2345 ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS 3916 S Ave,Anacortes,WA,98221 angelajcurrie@gmail.com CONTRACTOR INFORMATION NAME* PHONE Banner electric 360-755-3030 CONTRACTOR'S BUSINESS LICENSES STATE LICENSE# EXPIRATION *All Contractors&Subcontractors must have a valid City EC BANNEE1965RP 1/5/2023 of Anacortes business license prior to doing work in the UBI# EXPIRATION City. 602453660 1/5/2023 ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS 130 E Hazel Ave,Burlington,WA,98233 gk.bannerelectric@gmail.com Page 1 of 17 Res.Building Permit Application Submittal Checklist Updated April 20,2021 CONTACT PERSON -Select one person the city will contact for anything related to this project: ❑APPLICANT []PROPERTY OWNER []CONTRACTOR ❑OTHER(LIST BELOW) NAME PHONE Aaron, Fonoimoana 360-755-3030 ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS 130 E Hazel Ave, Burlington,WA 98233 aaron@bannerpowersolutions.com LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lender involved with your project, write "no lenders"on the Name Line below. NAME PHONE Christina, Bagnall 425-283-5163 ADDRESS(STREET,CITY,STATE,ZIP) EMAILADDRESS 11201 SE 8th St suite 208,bellevue,WA 98004 christinab@psccu.org ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: 1 understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technically complete and sufficient for staff review. I understand that if 1 submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. I understand and acknowledge that I could be responsible for providing as-built drawings(on paper or electronically)as part of the project's certificate of occupancy process. G 1 understand and acknowledge that Special Inspections could be required as part of my project, and (� if needed 1 will be required to pay for the cost of these inspections. 1 understand and acknowledge that financial securities could be required as part of the work I am completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. 1 understand that if permits are reviewed concurrently such as design review, site plan, traffic concurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. I hereby declare that 1 am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. ,�QGiLe� �evzea,N,eG�r,� 06/22/2023 SIGNATURE DATE Aaron, Fonoimoana PRINTED NAME Res.Building Permit Application Submittal Checklist Updated December 2021 Page 2 of 17 Roof mounted conduit to conned arrays �O tOR CODgc0�A ioof mounted conduit to corm pv modules with wall LA mounted solar combiner O PTO FIELD 1NSe� Solar combiner and controller Solar AC disconnect Existing utility meter, electrical panel located --� directly on other side of wall from meter I condo 431fz" O/777 DOR CODE COS/ SG A 32" M 18" Q5 Pp FIELD 1N5 ENPAll- c�E PH SE ...............t.- IQ8 Series Microinverters Easy to install Our newest I108 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated Part of the Enphase Energy System,I08 Series IQ8 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- powered PV modules and analysis software. leading limited warranty of up to 25 years. Microgrid-forming • Complies with the latest advanced grid support** 6W=:C CERTIFIED Remote automatic updates for L_ SAFETY -A the latest grid requirements Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other *Only when installed with IQ System Controller 2,meets names are trademarks of Enphase Energy,Inc.Data subject to change. UL 1741.IQ811-208V operates only in grid-tied mode. **IQ8 Series Microinverters supports split phase,240V. I08SE-DS-0001-01-EN-US-2022-03-17 IQ8H-208 supports split phase,208V only. IQ8 Series Microinverters INPUT DATA IDCI ,: .1 , ,: , ,: 1 , 1: Commonly used module pairings' W 235-350 235-440 260-460 295-500 320-540+ 295-500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 Operating range v 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1' Q .1 ,: 1: 1:' ,: 1 ,: 1: Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal(L-L)voltage/range4 V 240/211-264 208/183-250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 4.4 3 cycles Arms Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm MY)x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor 1 CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)The I08H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-17 IRONRIDGE XR100 Rail See Des Lion / Length Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in .66 Section Modulus (X-axis) 0.297 in' .46 Moment of Inertia (X-axis) 0.390 in Moment of Inertia (Y-axis) 0.085 in T9- Torsional Constant 0.214 in Polar Moment of Inertia 0.126 in 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .58 1.25 Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) Alum-Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60 lbs. v1.1 SUNM*09h:7 We've Got Your Rack! 1. Nano Mount 1.97 (Rafter) [s0.01 0 1 0.31 [11 [7.8] _ I EF © �M T � �n 04.00 —� Material:Aluminum [0101.6] Finish: Black Powder Coati I — ------------------------------------ I I I 2. o.za [6.0] I I 3.66 —— [093.0] Material: USWR Silicone Foam Gasket with Adhesive ------------------------------------ 3. Hex Lag Bolt M8X115, DIN 571,304SS .. i.3� n15.01 •of 18ia3z81 I Part Description: Nano Rafter Mount, Black Part No.: K50044-BK1 05 It3.% u Material:Jtalnless Jteel Finish:Clear Item Description Qty in No. Kit 4. Sealing Washer.331D X.75X.157 1 Nano Rafter Mount Assembly • Nano Rafter Mount • Nano Gasket ` qo.73 119.0 + 119.0] ] 2 Lat Bolt Assembly • Hex Lag Bolt M8X115, DIN 571, 304S • Sealing Washer.33 ID X.75 X.157 �`� ; 00.33 I8.51 Material: EPDM+ Stainless Steel D10213-VO01 Dimensions shown are inches(and millimeters) Details are subjed to change without notice SUNMIOONX We've Got Your Rack! 1. Nano Mount 1.97 (Decking) [s0.0] 0 1 0.31 [11 [7.8] _ I AIM oC .� 04.00 Material:Aluminum [0101.6] Finish: Black Powder Coati ------------------------------------ [ [ [ 2. 024 1 � ¢3.66 [093.0] Material: USWR Silicone Foam Gasket with Adhesive ------------------------------------ 3. Self-Drilling Screw,#6.3 X 76 3.00 [76.3[ Part Description: Nano Deck Mount, Black Part No.: K50044-BK2 !N.3 Material:Stainless Steel Finish:Clear Item Description Qty in No. Kit 4. Sealing Washer.261D X.50X.125 1 Nano Deck Mount Assembly • Nano Deck Mount00.2 • Nano Gasket i �' R] I I � � 00.59 1 00.63 [75.01 [16.01 [ + [ 2 Decking Screw Assembly 4 • Self-Drilling Screw, #6.3 X 76 • Sealing Washer.261D X.50X.125 D10214-VO01 Dimensions shown are inches(and millimeters) Details are subject to change without notice Currie(#981137) A0k IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Project Details Name Currie Date 06/22/2022 Location 3916 S Avenue,Anacortes,WA 98221 Total modules 28 Module Silfab: SIL-370HC(35mm) Total watts 10,360 Dimensions Dimensions: 69.37"x 40.83" x 1.38" (1762.Omm x 1037.Omm x 35.Omm) Attachments 56 ASCE 7-10 Rails per row 2 System Weight Load Assumptions Total system weight 1,412.4 Ibs Wind exposure B Weight/attachment 25.2 Ibs Wind speed 110 mph Racking weight 208.7 Ibs Ground snow load 15 psf Distributed weight 2.5 psf Attachment spacing portrait 4.0' Roof Information Roof Material Family Comp Shingle Roof material Comp Shingle Building height 30 ft Roof attachment None Roof slope 17 ° Attachment hardware Square Risk category II Span Details XR100 - Portrait Reaction Forces XR100 Portrait Zone Down Uplift Lateral Zone Max span Max cantilever (Ibs) (Ibs) (Ibs) 1 8' 3" 3' 1 216 93 52 2 8' 3" 3' 2 216 194 52 3 8' 3' 3 216 309 52 9�ag CODE co �o Last updated by Guy Knoblich on 06/22/22 08:31 PIA Page 1 of 6 Currie(#981137) AOk IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Roof Section 1 Details Weights Panels: 18 Provided rail: 136' [8 x 204"] Total weight: 877.6 Ibs Rail orientation: East-West Attachments: 32 Weight/attachment: 27.4 Ibs Panel orientation: Portrait Splices: 4 Total Area: 359.8 sq ft Entry type: Graphical Clamps: 32 Distributed weight: 2.4 psf Diagram io kb 30' 10" Segments Identifier Columns Row Rail Cantilever Cantilever Rail Attachments Splices Clamps length length Violations A 9 31' 31' 1' 6" None 68' [4 x 16 2 16 204"] Row segment totals (x 2) 136' [8 x 32 4 32 204"] Contour Plan -Trim Cut List Identifier Scrap from Length Scraps Created Discard Roof Section 2 Last updated by Guy Knoblich on 06/22/22 08:31 PM Page 2 of 6 Currie(#981137) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 et I s weights oo ection 2 Panels: 10 Provided rail: 140' [10 x 168"] Total weight: 534.8 Ibs Rail orientation: East-West Attachments: 24 Weight/attachment: 22.3 Ibs Panel orientation: Portrait Splices: 2 Total Area: 201.7 sq ft Entry type: Graphical Clamps: 12 Distributed weight: 2.7 psf Diagram n r-I rl 2 4' Segments Identifier Columns Row Rail Cantilever Cantilever Rail Attachments Splices Clamps length length Violations A 5 17' 4" 17' 4" 8" None 56' [4 x 10 2 8 168"] B 1 3' 7" 3' 7" 0" None 28 [2 x 4 0 0 168"] Row segment totals (x 2) 56' [4 x 8 0 0 168"] C 3 10' S" 10' S" 1' 3" None 28 [2 x 6 0 4 168"] Contour Plan -Trim Cut List Identifier Scrap from Length Scraps Created Discard Last updated by Guy Knoblich on 06/22/22 08:31 PM Page 3 of 6 Currie(#981137) 40k IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Splice Details TOP-FACING SLOT XR100 RAIL NTERNAL SPLICE Y BONDING SPRING bur_- XR100 INTERNAL SPLICE SIDE-FACING SLOT Splice Connection XR100 Clamp Detail PV MODULE UNIVERSAL FRAME FASTENING .r'` --' _- PV MODULE PV MODULE OBJECT FRAME ~� FRAME ------- - - ----- UNIVERSAL '5 , ________ FASTENING PV MODULE RAIL -------- OBJECT FRAME D 0 CAMO CAMO RAIL RAI L Mid Clamp,Plan Mid Clamp,Front CAMO End Clamp,Plan CAMO End Clamp,Front Last updated by Guy Knoblich on 06/22/22 08:31 PM Page 4 of 6 Currie(#981137) A0k IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Grounding Diagram L L- - - - - - 0 - - - - - - - - - - - - - - - - - - - - - - - - - - 0 --- 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0 - - - - - - - - - - - - - - - - - - T o - - - - - - - - - - - - - - - - - - - - - - - - - - ! - - - - - - - 0 OUFO Clamp • Grounding Lug * Fault Current Ground Path Min 10 AWG Copper Wire m Bonded Splice (Rail Connection) *Grounding Lugs and Wire are not required in systems using Enphase microinverters. Last updated by Guy Knoblich on 06/22/22 08:31 PIA Page 5 of 6 Currie(#981137) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Bill of Materials Part Spares Total Qty Rails & Splices XR-100-204B 0 8 XR100,Rail 204"(17 Feet)Black XR-100-168B 0 10 XR100,Rail 168"(14 Feet)Black XR100-BOSS-01-M1 0 6 Bonded Splice,XR100 Clamps&Grounding UFO-CL-01-B1 0 44 Universal Module Clamp,Black CAMO-01-M 1 0 24 Hidden End Cam(universal clamp) XR-LUG-03-Al 0 6 Grounding Lug,Low Profile Attachments BHW-SQ-02-Al 0 56 Square-Bolt Bonding Hardware Last updated by Guy Knoblich on 06/22/22 08:31 PM Page 6 of 6