HomeMy WebLinkAboutBLD-2026-0336 - ACCESSORY DWELLING UNIT/ADUFIXTURES
Qty Mechanical Fixtures
1 Air Conditioner / Handler
1 Range Hood
1 Refrigeration Unit
1 Stove/Range/Oven
1 Heat Pump
1 Stackable Washer Dryer
1 Tankless Water Heater
2 Wall Heater
Qty Plumbing Fixtures
PARCEL: P33069
LEGAL DESCRIPTION: (0.2000 ac) TAX 32AAA E 60FT OF FOL TR BAAP 520.5FT E & 417.4FT N OF SW C GOVERNMENT LOT
2, SECTION 30, TOWNSHIP 35 NORTH, RANGE 2 EAST, W.M., TH E 482.3FT TH S 100FT TH W 482.3FT TH N 100FT TPB LESS
E 60FT & TAX 32AAB
APPLICANT: Parkins, Kristin
812 37TH ST
Anacortes, WA 98221
4153108312
OWNER: PARKINS JUSTIN
PARKINS KRISTIN
ANACORTES, WA 98221
VALUATIONS:
Heated Living Space 892.00 $152,353.60
$152,353.60Total:
FEES:Paid Due
State Building Code Council fee $6.50 $0.00
Building Permit Fee $1,290.55 $0.00
Plan Review Fee $838.86 $0.00
Storm Water Review Sq Ft $71.36 $0.00
Mechanical and plumbing
remodel fixtures fees
$166.70 $0.00
$0.00Totals :
CONSTRUCTION CONTRACTOR:NORTH COAST DESIGN LLC
6410 spradley rd
ANACORTES, WA 98221
425-356-7705
License: NORTHCD809O9
Expires: 09/09/2027
$2,373.97
BLD-2026-0336 ACCESSORY DWELLING UNIT/ADU
ISSUED:
EXPIRES:
08/17/2026
08/17/2027
PROJECT NAME: 808 COTTAGE
SITE ADDRESS: 808 37TH STREET ANACORTES
Page 1 of 2Printed by : Jennifer Watson on: 08/28/2026 09:08 AM
City of Anacortes, WA
904 6th Street
Anacortes, WA 98221
(360) 293-1901
http://cityofanacortes.org/
Please request inspections online through the permit portal.
If that is not possible please call (360) 293-1901 for Building or Planning inspections.
For Public Works inspections, please call (360) 293-1938.
REQUIRED INSPECTIONS
Initial BMP's. This stormwater inspection must be
completed prior to any other inspections.
Sewer Line
Storm Drain Connection
Footings
Perimeter Drains
STORMWATER BMPS 1ST MID PROJECT INSPECTION
Foundation
Underfloor
Underground Plumbing
Underslab
Mechanical Rough-In
Gas Piping
Plumbing Rough-In
Shear Wall and Nailing
Framing
STORMWATER BMPS 2ND MID PROJECT INSPECTION
Insulation
Fenestration U-Factors
Drywall or Lath
Roofing Final
Permeable Soil Depth
Public Works Final
Building Final
Stormwater Final
Page 2 of 2Printed by : Jennifer Watson on: 08/28/2026 09:08 AM
City of Anacortes, WA
ACCESSORY DWELLING UNIT/ADU BLD-2026-0336
Planning, Community, & Economic Development Department
904 6th St, Anacortes, WA 98221
pced@anacorteswa.gov
(360) 293-1901
*The applicant is responsible for compliance with all codes and regulations, whether or not described in this document*
Permitting Application Requirements and Checklists Submittal Standards – Page 32
4.7 Stormwater Documentation
4.7.1 Stormwater Self-Assessment
Answer the following questions to determine the stormwater requirements that apply to your project.
Question Response Unit
1. What is the parcel size of the site to be developed? Square Feet
2. What is the total area of already existing hard surfaces? Square Feet
3. What is the total land area that will be disturbed during this project? Square Feet
4. What is the total area of new hard surfaces? Square Feet
5. What is the total area of to-be replaced hard surfaces? Square Feet
6. How much vegetation will be converted to lawn/landscaped area? Square Feet
7. How much native vegetation will be converted to pasture? Square Feet
8. Does the site have 35% or less of existing hard surface coverage?
☐ YES: This project is considered a “new development.” ☐ NO: This project is considered a “re-development.”
Answer the questions below based on whether your project is a New Development or Re-Development.
NEW DEVELOPMENT RE-DEVELOPMENT
N1. Does the project result in 5,000 sq.ft. or greater of new
and replaced hard surface?
R1. Does the project add 5,000 sq. ft. or more of new hard
surfaces? OR Convert 32,670 sq. ft. (3⁄4 acre) or more of
vegetation to lawn or landscaped area? OR disturb
greater than 1 acre of land? OR Convert 2.5 acres or more
of native vegetation to pasture?
☐ YES
Large Project Stormwater
Plan [see next page]
☐ NO
Proceed to question N2
N2. Does the project convert 3⁄4 acre (32,670 sq.ft.) or
more of vegetation to lawn or landscaped area, or
convert 2.5 acres or more of native vegetation to pasture?
☐ YES
Large Project Stormwater
Plan [see next page]
☐ NO
Proceed to question R2
☐ YES
Large Project Stormwater
Plan [see next page]
☐ NO
Proceed to question N3
R2. Does this project result in 2,000 sq. ft., or more, of new
plus replaced hard surface area? OR is the land disturbing
activity greater than 7,000 sq. ft. but less than 1 acre?
N3. Does the project result in 2,000 sq.ft. or greater of
new plus replaced hard surface area?
☐ YES
Proceed to question R3
☐ NO
Minimum Requirement 2
Only [see next page]
☐ YES
Small Project Stormwater
Plan [see next page]
☐ NO
Proceed to question N4
R3. Is the total of new plus replaced hard surfaces 5,000
sq. ft. or more, AND does the value of the proposed
improvements – including interior improvements – exceed
50% of the assessed value (or replaced value) of the
existing site improvements?
N4. Does the project have land disturbing
activities greater than 7,000 sq.ft. but less than an acre?
☐ YES
Small Project Stormwater
Plan [see next page]
☐ NO
Minimum Requirement 2
Only [see next page]
☐ YES
Large Project Stormwater
Plan [see next page]
☐ NO
Small Project Stormwater
Plan [see next page]
Upon completion of the stormwater questionnaire, use Table 1 and Table 2 to determine the required stormwater
management practices, and provide the appropriate materials with submission of your completed building permit
application.
677827945765760800x
x
x
x
Kristin & Justin Parkins 808 37th StAnacortes
Planning, Community, & Economic Development Department
904 6th St, Anacortes, WA 98221
pced@anacorteswa.gov
(360) 293-1901
*The applicant is responsible for compliance with all codes and regulations, whether or not described in this document*
Permitting Application Requirements and Checklists Submittal Standards – Page 33
Please indicate the level of Stormwater Management your project is required to meet:
☐ MR #2 Only
☐ Small Project (MR #1-5)
☐ Large Project (MR #1-9)
☐ Exempt
Table 1: Washington State Department of Ecology Minimum Requirements (MR)
MR #1: Preparations of stormwater site plans
MR #2: Construction Stormwater Pollution Prevention Plan (SWPPP)
MR #3: Source control of pollution
MR #4: Preservation of natural drainage systems and outfalls
MR #5: On-site stormwater management
MR #6: Runoff treatment
MR #7: Flow control
MR #8: Wetlands protection
MR #9: Operation and maintenance
Table 2: Stormwater Management Information
Requirement Description Required
MR #2 Only A complete Construction SWPPP does not need to be prepared and
submitted to meet this requirement. However, the project proponent must
consider all 13 Elements of Construction Stormwater Pollution Prevention
and develop controls for all elements of the project.
Additional Resources
USSG 6.05.03
SWMMWW Vol.1-2.5.5
Small Project
Stormwater Plan
(MR #1-5)
Small projects are required to meet Minimum Requirements #1-5. These
projects are generally less impactful and therefore require less stormwater
protection and mitigation eff orts. These projects have the option to use
the City’s pre-engineered worksheets, templates, and forms to construct
an a Small Stormwater Management Plan.
Additional Resources
USSG 5.04.01.1
SWMMWW Vol.1-Ch.2
Large Project
Stormwater Plan
(MR #1-9)
Large projects are required to meet all Minimum Requirements (#1-9).
These projects are either impactful by design or are being developed in an
environmentally sensitive and/or critical area. The project proponent is
required to retain professional engineering services to prepare and submit
a detailed report that addresses site specific stormwater concerns and
engineered solutions that meet WA State specifications.
Contact a Licensed
Engineering Firm
Additional Resources
USSG 5.04.01.2
SWMMWW Vol.1-Ch.2
Demolition Applicant should at least meet Minimum Requirement #2 and follow the
Department of Ecology BMPs for demolition
Projects in an
Existing Platted
Development
If the project is in a recorded plat, the applicant should review the plat
language and the original drainage report to check for any restrictions on
building square footage. This review should also extend to water, sewer,
and easement documentation
Links to resource documents below.
• SWMMWW: WA State Dept. of Ecology’s Stormwater Management Manual for Western Washington, 2024
x
Planning, Community, & Economic Development Department
904 6th St, Anacortes, WA 98221
pced@anacorteswa.gov
(360) 293-1901
*The applicant is responsible for compliance with all codes and regulations, whether or not described in this document*
Permitting Application Requirements and Checklists Submittal Standards – Page 34
4.7.2 Stormwater Prevention Plan Minimum Requirements
Please refer to the following link:
https://www.anacorteswa.gov/DocumentCenter/View/24761/Stormwater-Drainage-Report-Minimum-
Requirements-2--04-23-2024
4.7.3 Stormwater Management Activity Report
(Required to be provided during project construction)
Required Elements
☐ 1. Runoff Calculations
☐ 2. Documentation of compliance with the Stormwater Management Manual for Western
Washington
☐ 3. Upstream and Downstream Analysis
☐ 4. Maintenance Plan for proposed and existing drainage facilities
☐ 5. Feasibility Analysis for Low Impact Development (LID)
☐ 6. Soil Analysis Report with wet and dry season testing
DRAWN BY: BRUCE RUSTAD
EXISTING & PROPOSED SITE PLAN
DATE: 04/18/26
SCALE: 1" =20'-0" ON 11" x 17" PAPERSCALE: 1" =10'-0" ON 22" x 34" PAPER
NOTES:
1. DURING CONSTRUCTION, THE RUN OFF WILL BE CONTROLLED WITH
ADJACENT PROPERTY.SILT FENCES AND SHALLOW SWALES TO PROTECT THE
PROTECTOR INSTALLED PER WSDOT DETAIL 1-40.20-002. THE STREET STORM WATER CATCH BASIN WILL HAVE A STORM DRAIN INLET
3. STREET AND DITCHES WILL BE CLEANED DAILY OF ERISION RUN-OFF IF ANY.
4. BEFORE CONSTRUCTION BEGINS, A SITE WALK WILL TAKEPLACE TO IDENTIFY THE CONDITION OF THE STREET, CURB & GUTTER.ALL BROKEN AREAS WILL BE REPLACED TO THE CITY'S APPROVALPRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
PARCEL #: P33069 & P56650
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITHBUILDER TO VERIFY ALL DIMENSIONS
7,066 SQ. FT.
25.9%
PERCENT OF COVERAGE
LOT AREA (BOTH LOTS)HOUSE
PERCENT OF COVERAGE
EXISTING
EXISTING IMPERVIOUS AREA
PERCENT OF IMPERVIOUS 56%
DRIVEWAY & SIDEWALKS
5. TIE-INTO CITY WATER & SANITARY SEWER.
DRAWING INDEX:
1. PROPOSED SITE PLAN2. EXISTING & NEW ELEVATIONS
4. EXISTING & NEW FOUNDATION PLAN
5. EXISTING & NEW ROOF PLAN6. SECTIONAL DETAILS
3. EXISTING & NEW FLOOR PLANS
1
1 of 7
ZONED R-3
LOT AREA
TOTAL IMPERVIOUS 3,964 SQ. FT.
7. EXCESS CONCRETE TO BE REMOVED
1,238 SQ. FT.
37TH STREET
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
59.99'N 89d 56' 34" E
59.99'N 89d 56' 34" E
VACATED ALLEY
SEWER
EXISTING SITE PLAN
EXISTING HOUSE
EXISTING GARAGE
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
PO
R
C
H
WOODEN FENCE
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
TREE
BUSH
BUSH
BUSH
TREE
7.6'
3.8'
12./7'
REMOVE THISPORTION
REMODEL THISPORTION
GRASS
GRAVEL
GRASS
GRASS
37TH STREET
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
59.99'N 89d 56' 34" E
59.99'N 89d 56' 34" E
SEWER
CITY WATER
PROPOSED SITE PLAN
EXISTING HOUSE
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
TREE
BUSH
BUSH
BUSH
TREE
3.8'
GRASS
GRASS
GRASS
EXISTING GARAGEREMODELED INTO AN ADU
PERCENT OF COVERAGE
PERCENT OF COVERAGE
NEW
GARAGE 600 SQ. FT.TOTAL 1,838 SQ. FT.
892 SQ. FT.ADUTOTAL 2,130 SQ. FT.
30%
HOUSE GARAGE 1216 SQ. FT.
NEW IMPERVIOUS AREA
PERCENT OF IMPERVIOUS 49 %
DRIVEWAY & SIDEWALKS
LOT AREA
TOTAL IMPERVIOUS 3,473 SQ. FT.
HOUSE 892 SQ. FT.ADU
PATIO 127 SQ. FT.
5.79'
10.71'
25.6'
4.6'
20'
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
7. BRACE WALL PLAN
25.6'
20'
EXISTING
DOWNSPOUTEXISTING
DOWNSPOUTEXISTING
4" SOLID PVCNEW
TO INTO EXISTINGDRAINAGE SYSTEM
4" SOLID PVCEXISTING
DOWNSPOUTNEW
DOWNSPOUTNEW
BMP C233SILT FENCE
BMP C233SILT FENCEBMP C233SILT FENCE
9' x 14'PATIO
CO
N
C
R
E
T
E
B
O
R
D
E
R
6x6 BORDER
TREE
TREE
GRAVEL
GRAVEL
GR
A
V
E
L
GRASS
FL
O
W
E
R
B
E
D
CITY WATERNEW
6x6 BORDER
TREE
TREE
FL
O
W
E
R
B
E
D
REV. #1 05/13/26
P33069
P56650
7,066 SQ. FT.LOT AREA (BOTH LOTS)HOUSE 1,238 SQ. FT.
GRAVEL AREA 910 SQ. FT.
600 SQ. FT.1,238 SQ. FT.7,066 SQ. FT.
7,066 SQ. FT.1,238 SQ. FT.
1,216 SQ. FT.
600 SQ, FT.
1238 SQ, FT.
(ORINANCE NO.475)(ORINANCE NO.475)VACATED ALLEY
127 SQ, FT.
Legal Description P33069: TAX 32AAA E 60 ft OF FOL TR BAAP 520 ft. E &
4127 FT. N OF SW C GOVERNMENT LOT 2, SECTION 30. TOWNSHIP 35NORTH, RANGE 2 EAST, W.M. TH E 482.3 FT TH S 100 FT. TH W 482.3 FT TH N
100 FT TPB LESS E 60 FT. & TAX 32AAB.
Legal Description P56650: FRACTIONAL LOTS 17 AND 18. BLOCK 12, BEALE'S
MAPLE GROVE ADDITION TO THE CITY OF ANACORTES, ACCORDING TOPLAT THERE OF RECORDED IN VOLUMN 2 OF PLATS. PAGE 19, RECORDS OF
SKAGIT COUNTY, WASHINGTON. TGW S1/2 OF VAC ALLEY
NOTE: Lots will be merged byconstruction. Staff encouragesthe property owner to combinethe two parcels with SkagitCounty in order to have onetax parcel in the future.
CO
N
C
R
E
T
E
D
R
I
V
E
W
A
Y
GRAVEL GRAVELGRAVELGRAVEL
CITY WATER
THREE OFF STREET PARKING
TWO ON STREET PARKING
THREE OFF STREET PARKING
TWO ON STREET PARKING
CITY WATEREXISTING
SEWEREXISTING
SEWERNEW
EXISTING
DRAINAGEDOWNSPOUTEXISTING
6. TIE-INTO EXISTING DOWNSPOUT DRAINAGE
26%
7/9/2026
WSU Code Compliance Calculator, WSEC 2021
Project Information Messages / Comments *
0
Note: Review of Baseline Required - Review required for custom entries: - Doors- Floors- Below Grade Wall
UA Reduction = -79.98 is negative compared to user-defined baseline UA. Check required % reduction compared to Addition's UA.
Contact Information
-
Whole House Mechanical Ventilation Airflow Rate: 43.75 CFM with Run Time Percent of 100%, Balanced, Not Distributed
ANALYSIS SET UP
What code compliance pathway are you using?
Project Building Type?
Occupancy Type?
Code Version?
Classification:Small Dwelling Unit -- 892 sq. ft.
Baseline Description: Existing Baseline - Maximum baseline window area is 15% of floor area per Option 1 UA % reduction calculation (Section R402.1.5).
About Your Selection:No exempt window or door areas. Enter baseline design details to right of proposed design below
-
RESULTS - Comparison of Baseline and Proposed Design **
Component Performance, R occupancies
U *Area UA Area UA
Doors U =0.300 20 6.0 69 19.4
Overhead Glazing U =0.000 0 0.0 0 0.0
Vertical Glazing U =0.300 160 48.0 67 14.6
Flat/Vaulted Ceilings U =0.020 491 9.8 1,578 39.5
Wall (above grade) U =0.056 1,134 63.5 1,453 61.0
Floors over Crawlspace U =0.000 0 0.0 1,578 71.0
Slab on Grade F =0.540 139 75.1 136 35.5
Below Grade Wall U =0.000 0 0.0
Below Grade Slab F =0.000 0 0.0 136 41.3 0.30 =eff F of below grade wall and slab
* Values from user-defined baseline
Baseline UA Total 202.4 Proposed UA Total 282.4
Required Credits 0 Proposed Credits 5.0
UA Percent Reduction Calculate %UA reduction based on Addition UA
UA Reduction -80.0
** Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
Total Credits
(406.2 & 406.3)
5.0
* Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
0.0
0.0
Efficient Building Envelope
3.1 -3.10
1
3.11
4
High Efficiency HVAC: Smart Thermostat 0.0
High Efficiency HVAC Distribution System
0.220
0.025
0.042
0.045
0.261
0.304
Proposed Design
User-Defined Baseline (Addition/Remodel/Alteration of Existing)
U
Baseline Design
Addition / Remodel / Alteration
R3 Single family dwellings and townhouses
WSEC 2021
0.279
3.0
Full Description
For heating system based on electric resistance with (1) inverter driven ductless mini-
split heat pump system installed in the largest zone in the dwelling OR (2) With 2kW
or less total installed heating capacity per dwelling
High Efficiency HVAC
Not Selected
System No.
5
1.0
Brief Description of Selected Options*
1.0
Category
Select System Type
Energy Credits
Option 2.1
Fuel Normalization
Credits (406.2)
Table R406.2 Energy Equalization Credits
2.0
Electric Resistance with Ductless Heat Pump
OR electric resistance with max 2 kW
installed capacity
Table R406.3 Energy Credits
Energy Credits (406.3)
Select Options
Option 1.2
Perscriptive compliance per Table 402.1.3 / U-0.25 vertical fenestration /
R-38 floors or R-10 perimeter & fully insulated slab. Or 15% reduction in
UA per section R402.1.5
Per Section R402.4.1.2 / 2.0 ACH50 / For R-2, 0.25 cfm per ft2 at 50 Pa.
/ HRV with min SHR eff of 0.65 per IRC Section M1505.3 or IMC Section
403.8
Option No.
2 Air Leakage Control and Efficient Ventilation
WSU_C32021_20241009~Mamor Lot 6.xlsm, Version:10/9/2024 4:07:13 PM 10/16/2024 1
WSU Code Compliance Calculator, WSEC 2021
Renewable Electric Energy 3,000 kWh
Energy Credits
*Refer to WSEC 2021 Table R406.3 for complete option descriptions and requirements
0.0
Energy star gas or propane water heater with min UEF of 0.91 OR Solar
supplemental water heating OR GSHP meeting requirements of Option
3.4
0.0
3.0
7 Appliance Package
https://sbcc.wa.gov/state-codes-regulations-guidelines/state-building-code/energy-code
6
1.0
Efficient Water Heating: Drain Heat Recovery
Efficient Water Heating
Efficient Water Heating: Compact Hot Water Distribution
5.1
5.3-5.8
5.2
Option 5.4
0.0
0.0
WSU_C32021_20241009~Mamor Lot 6.xlsm, Version:10/9/2024 4:07:13 PM 10/16/2024 2
WSU Code Compliance Calculator, WSEC 2021
THERMAL ENVELOPE DETAILS - Proposed Design
Conditioned Floor Area, Proposed Design 892 sq. ft
Classification Small Dwelling Unit
Exterior Doors
Plan Component Door
ID Description Ref.U Qt.Feet Inch Feet Inch Area UA
pg 3, E front doorCode Baseline, U=0.30 - 0.30 1 3 2 6 10 22 6.5
pg 3, E patio doorFrench/Glass Door Custom 0.27 1 7 0 6 10 48 12.9 Refer to WSEC R402.1.5 U-factor Reference and Calculations
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
Sum of Area and UA 69 19.4 0 1
Exterior Doors Area Weighted U 0.279
Overhead Glazing
Plan Component Glazing
ID Description U Feet Inch Feet Inch
-
-
-
-
-
0.0 0 0 0
Overhead Glazing Area Weighted U
Vertical Glazing Schedule Rows to Show 16
Plan Component Glazing
ID Description U Feet Inch Feet Inch
1 pg 3, A U=0.22 (2021 1.1; 2018 1.5)Table 406.2 / 406.3 0.22 2 4 0 4 0 32.0 7.04
2 pg 3, B U=0.22 (2021 1.1; 2018 1.5)Table 406.2 / 406.3 0.22 2 1 3 5 0 12.5 2.75
3 pg 3, C U=0.22 (2021 1.1; 2018 1.5)Table 406.2 / 406.3 0.22 1 3 6 3 0 10.5 2.31
4 pg 3, D U=0.22 (2021 1.1; 2018 1.5)Table 406.2 / 406.3 0.22 1 3 0 3 0 9.0 1.98
5 pg 3, E U=0.22 (2021 1.1; 2018 1.5)Table 406.2 / 406.3 0.22 1 2 6 1 0 2.5 0.55
6 - -
7 - -
8 - -
9 - -
10 - -
11 - -
12 - -
13 - -
14 - -
15 - -
16 - -
Sum of Area and UA 66.5 14.6 0
Vertical Glazing Area Weighted U 0.220
Vertical Glazing and Doors Area Weighted U 0.250
Flat/Vaulted Ceilings
Plan Component Attic
ID Description U
Flat R60 blown Attic STD baffled 10-7 0.025 1,578 39.5
1,578 39.5 0
Area Weighted U-Value 0.025
Walls (Above Grade)
Plan Component Wall
ID Description Ref.U UA
Width
Ref.
Ref.
Height
Notes
Height
Area
Width
Qt.
Sum of Area and UA
Qt.UAArea
HeightWidth
Sum of Area and UA
Ref.
Net Area
Area
UA
UA
WSU_C32021_20241009~Mamor Lot 6.xlsm, Version:10/9/2024 4:07:13 PM 10/16/2024 3
WSU Code Compliance Calculator, WSEC 2021
All walls and ceilingR21 cavity+R5 foam INT 2X6W T111 10-5 0.042 1,453 61
1,453 61 0
Gross Wall Area 1,589 ft2
Area Weighted U-Value 0.042
Sum of Net Area and UA
WSU_C32021_20241009~Mamor Lot 6.xlsm, Version:10/9/2024 4:07:13 PM 10/16/2024 4
WSU Code Compliance Calculator, WSEC 2021
Floor (over crawl or exterior)
Plan Component Floor UA
ID Description Ref.U
pg 6 R20 Concrete Exposed Custom 0.045 1,578 71 Refer to WSEC R402.1.5 U-factor Reference and Calculations
1,578 71 1
Area Weighted U-Value 0.045
Slab on Grade (less than 2 feet below grade)
Plan Component Slab
ID Description Ref.F FP
pg 6 R20 Fully insulated (2018 1.6)Table A6.3, ASHRAE 90.10.261 136 35
136 35 0
Area Weighted U-Value 0.261
Below Grade Walls and Slabs
Plan Component Slab Wall Wall Wall Slab
ID Description Depth Ref.U Area UA FP
pg 6 22- R20 Foam Ext w/TB 7' depth Custom 0.034 0 0.0 136 41 Refer to WSEC R402.1.5 U-factor Reference and Calculations
Sum of Area, Length and UA 0 0 136 41 1
Weighted U- and F-values 0.304
Effective F-value 0.30
Links to Download Forms, Checklists and Other Resources
Compliance Certificate Instructions
Insulation Certificate for Residential New Construction
Duct Testing Affadavits
Existing Construction
New Construction
Prescriptive Checklist for 2018 WSEC
Alterations (Remodel) Worksheet
EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter
Show
Ventilation Requirements
Conditioned Floor Area 892 sq. ft.
Number of Bedrooms 2
Run-Time Percent in Each 4-Hour Segment 100%
Is the system Balanced?Verify system meets definition of 'Balanced Whole-House Ventilation'
Is the system Distributed?
Ventilation Code Section IRC, Chapter 15
Whole House Mechanical Ventilation Airflow Rate 44 CFM
Show
HVAC Thermal Distribution System Download RS-33 (2018)
Is this a hydronic heating system?
Location of Ducts
Location of Air Handler
For Existing Construction: Are Any of These Exceptions True?
No
No -
No
Yes
Is Duct Testing Required?No
Maximum Duct Leakage:
Yes
Maximum total measured duct leakage per square foot 0.04 CFM25 per sq. ft.
Maximum allowable total measured duct leakage 36 CFM25
http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%20_2018%20WSEC.pdf
Unducted
Link
Prescriptive Checklist
Affidavit, Existing
Affidavit, New
Worksheet
Is this a post-contruction test?
No
Sum of Perimeter and FP
0.304
Slab Slab
Perim
Is there less than 40 linear feet in unconditioned spaces? (not excepted under
WSEC 2021)
Are existing duct systems constructed, insulated or sealed with asbestos?
Is the project an Addition less than 750 sf of conditioned floor area?
Unducted
Area
Insulation Certificate
Sum of Area and UA
Not Distributed
Are ducts systems documented to have been previously sealed as confirmed
through field verification and diagnostic testing per RS-33?
Balanced
Show Distribution System Calculator?
Show Ventilation Calculator?
Compliance Certificate
Slab
Perim
F
WSU_C32021_20241009~Mamor Lot 6.xlsm, Version:10/9/2024 4:07:13 PM 10/16/2024 5
WSU Code Compliance Calculator, WSEC 2021
Show
Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool:
Nearest Weather Station
Indoor Design Temperature 70 F
Outdoor Design Temperature 24 F
Design Temperature Difference (∆T)46 F
Conditioned Floor Area, Proposed Design 892 ft2
Conditioned Volume 7,000 ft3 Average ceiling height =7.8 ft. Volume = 7000 ft3 0.00
Leave blank to use default of 8.5 ft. ceiling height
Average ceiling height 7.8 ft
HVAC System Type
Location of HVAC Distribution System Unducted
Sum of UA 282
Envelope Heat Load 12,989 Btu / Hour
Sum of UA X ∆T
Air Leakage Heat Load 3,478 Btu / Hour
((Volume X 0.6) X ∆T) X .018))
Building Design Heat Load 16,467 Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load 16,467 Btu / Hour
For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1
For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 23,053 Btu / Hour
Building and Duct Heat Loss X 1.25 for heat pumps 6.8 kW
Building and Duct Heat Loss X 1.40 for all other systems
https://betterbuiltnw.com/resources/hvac-sizing-tool
Show Heating System Sizing?
Heat Pump
Anacortes
WSU_C32021_20241009~Mamor Lot 6.xlsm, Version:10/9/2024 4:07:13 PM 10/16/2024 6
WSU Code Compliance Calculator, WSEC 2018
Project Information Messages / Results *
808 37th St Credit requirements are not met. Select energy credits from Tables 406.2 and 406.3 below
ADU Review required for custom entries: - Doors
UA Reduction = 33.28, Proposed UA is better than baseline by 17%
Contact Information UA reduction meets percent target of selected Option 1
North Coast Design LLC -
ANALYSIS SET UP
What code compliance pathway are you using?
Project Building Type?
Occupancy Type?
Code Version?WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/OTS-5010.1_post.pdf
Classification:Small Dwelling Unit -- 892 sq. ft.
Baseline Description: Code Baseline - Baseline and proposed window areas are equal.
About Your Selection:Up to 15 sf exempt window and 24 sf exempt door allowable
RESULTS - Comparison of Baseline and Proposed Design
Component Performance, R occupancies
U *Area UA Area UA
Doors U =0.300 69 20.8 69 19.4
Overhead Glazing U =0.500 0 0.0 0 0.0
Vertical Glazing U =0.300 67 20.0 67 14.6
Flat/Vaulted Ceilings U =0.024 892 21.4 892 21.4
Wall (above grade) U =0.056 1,021 57.2 1,021 55.1
Floors over Crawlspace U =0.029 0 0.0 0 0.0
Slab on Grade F =0.540 136 73.4 136 49.0
Below Grade Wall U =N/A 0 0 0.0
Below Grade Slab F =N/A 0 0 0.0
* Values from Table R402.1.2 (Oct 2023)
Baseline UA Total 192.8 Proposed UA Total 159.5
Required Credits 5.0 Proposed Credits 4.5 from Tables 406.2 and 406.3
UA Percent Reduction 17.3%
UA Reduction 33.3
If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406 are ≥ those required in Section R406, then the home meets the WSEC.
Total Credits
(406.2 & 406.3)
4.5
0.220
0.024
0.054
0.360
Proposed Design
Table R406.3 UA Trade Off
U
Baseline
New Construction
R3 Single family homes and duplexes
WSEC 2021
0.279
1.0
Brief Description of Selected Options*
1.0
Category
Select System TypeSystem No.
2
Option 2.1
Fuel Normalization
Credits (406.2)
1
3.0
Full Description
For heating system using a heat pump that meets federal standards for the equipment
listed in Table C403.3.2(2) and supplemental heating provided by electric resistance
or a combustion furnace meeting minimum standards Listed in Table C403.3.2(5)b
found in the 2021 WSEC - COMMERCIAL ENERGY CODE.
High Efficiency HVAC
Energy Credits
3.11 High Efficiency HVAC: Smart Thermostat 0.0
Table R406.2 Energy Equalization Credits
1.5Heat Pump with Supplemental Heating
Select Options
Option 1.2
Perscriptive compliance per Table 402.1.3 / U-0.25 vertical
fenestration / R-38 floors or R-10 perimeter & fully insulated
slab. Or 15% reduction in UA per section R402.1.5
Per Section R402.4.1.2 / 2.0 ACH50 / For R-2, 0.25 cfm per ft2
at 50 Pa. / HRV with min SHR eff of 0.65 per IRC Section
M1505.3 or IMC Section 403.8
Table R406.3 Energy Credits
Option No.
2 Air Leakage Control and Efficient Ventilation
Efficient Building Envelope
3.1 -3.10
Energy Credits
(406.3)
* Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
0.0
1/25/2024C:\Users\kylem\Desktop\C3 Calculator.xlsm 8/7/2026
WSU Code Compliance Calculator, WSEC 2018
Renewable Electric Energy kWh
Energy Credits
*Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements
4
Option 5.4
0.0
0.0
High Efficiency HVAC Distribution System
7 Appliance Package
Efficient Water Heating: Drain Heat Recovery
Efficient Water Heating
Efficient Water Heating: Compact Hot Water Distribution
5.1
5.3-5.8
5.2
6
1.0
3.0
0.0
Energy star gas or propane water heater with min UEF of 0.91
OR Solar supplemental water heating OR GSHP meeting
requirements of Option 3.4
0.0
0.0
1/25/2024C:\Users\kylem\Desktop\C3 Calculator.xlsm 8/7/2026
WSU Code Compliance Calculator, WSEC 2018
THERMAL ENVELOPE DETAILS - Proposed Design
Conditioned Floor Area, Proposed Design 892 sq. ft
Classification Small Dwelling Unit
Exterior Doors
Plan Component Door
ID Description Ref. U Qt. Feet
Inch Feet Inch Area UA
Exempt 0 0.0
French/Glass Door Custom 0.27 1 7
0 6 10 48 12.9 Refer to WSEC R402.1.5 U-factor Reference and Calculations
Code Baseline, U=0.30 - 0.30 1 3
2 6 10 22 6.5
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
Sum of Area and UA 69 19.4 0 1
Exterior Doors Area Weighted U 0.279
Overhead Glazing
Plan Component Glazing
ID Description U Feet
Inch Feet Inch
-
-
-
-
-
0.0 0 0 0
Overhead Glazing Area Weighted U
Vertical Glazing Schedule Rows to Show 12
Plan Component Glazing
ID Description U Feet
Inch Feet Inch
Exempt - - -
1 U=0.22 (2021 1.1; 2018 1.5)Table 406.2 / 406.3 0.22 1 10 6.65 66.5 14.63
2 - -
3 - -
4 - -
5 - -
6 - -
7 - -
8 - -
9 - -
10 - -
11 - -
12 - -
Sum of Area and UA 66.5 14.6 0
Vertical Glazing Area Weighted U 0.220
Vertical Glazing and Doors Area Weighted U 0.250
Flat/Vaulted Ceilings
Plan Component Attic
ID Description U
R60 blown Attic STD baffled (2021 Code Baseline)10-7 0.024 892 21.4
892 21.4 0
Walls (Above Grade)
Plan Component Wall
UA
Area UARef.
Sum of Area and UA
Ref.
Ref.
Height
Notes
Height
Area
Width
Qt.
Sum of Area and UA
Qt. UAArea
HeightWidth
Width
1/25/2024C:\Users\kylem\Desktop\C3 Calculator.xlsm 8/7/2026
WSU Code Compliance Calculator, WSEC 2018
ID Description Ref. U UA
R21 cavity+R0 foam INT 2X6W Lap (2018 Code Baseline)10-5 0.054 1,021 55
1,021 55 0
Net Area
Sum of Area and UA
1/25/2024C:\Users\kylem\Desktop\C3 Calculator.xlsm 8/7/2026
WSU Code Compliance Calculator, WSEC 2018
Floor (over crawl or exterior)
Plan Component Floor UA
ID Description Ref. U
0 0 0
Slab on Grade (less than 2 feet below grade)
Plan Component Slab
ID Description Ref. F FP
R10 Fully insulated 10-2 0.360 136 49
136 49 0
Below Grade Walls and Slabs
Plan Component Slab Wall Wall Wall Slab
ID Description Depth Ref. U Area UA UA
Sum of Area, Length and UA 0 0.0 0 0 0
Links to Download Forms, Checklists and Other Resources
Compliance Certificate Instructions
Insulation Certificate for Residential New Construction
Duct Testing Affadavits
Existing Construction
New Construction
Prescriptive Checklist for 2018 WSEC
Alterations (Remodel) Worksheet
Show
Ventilation Requirements
Conditioned Floor Area 892 sq. ft.
Number of Bedrooms
Run-Time Percent in Each 4-Hour Segment
Is the system Balanced?
Is the system Distributed?
Ventilation Code Section IRC, Chapter 15
Whole House Mechanical Ventilation Airflow Rate CFM
Show
HVAC Thermal Distribution System Download RS-33 (2018)
Is this a hydronic heating system?
Location of Ducts
Location of Air Handler
Is Duct Testing Required? No
Show
Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool:
Nearest Weather Station
Indoor Design Temperature 70 F
Outdoor Design Temperature 24 F
Design Temperature Difference (∆T)46 F
Conditioned Floor Area, Proposed Design 892 ft2
Conditioned Volume ft3 Volume assuming ceiling height of 8.5 ft = 7582 ft3 0.00
Leave blank to use default of 8.5 ft. ceiling height
HVAC System Type Heat Pump
F
Slab Slab
Perim
Anacortes
Unducted
Show Heating System Sizing?
Area
No
Sum of Perimeter and FP
Slab
Perim
Compliance Certificate
Insulation Certificate
Sum of Area and UA
Show Distribution System Calculator?
Show Ventilation Calculator?
http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%20_2018%20WSEC.pdf
Unducted
https://betterbuiltnw.com/resources/hvac-sizing-tool
Link
Prescriptive Checklist
Affidavit, Existing
Affidavit, New
Worksheet
1/25/2024C:\Users\kylem\Desktop\C3 Calculator.xlsm 8/7/2026
WSU Code Compliance Calculator, WSEC 2018
Location of HVAC Distribution System Unducted
Sum of UA, including exempt door and window 160
Envelope Heat Load 7,339 Btu / Hour
Sum of UA X ∆T
Air Leakage Heat Load 3,767 Btu / Hour
((Volume X 0.6) X ∆T) X .018))
Building Design Heat Load 11,106 Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load 11,106 Btu / Hour
For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1
For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 13,882 Btu / Hour
Building and Duct Heat Loss X 1.25 for heat pumps 4.1 kW
Building and Duct Heat Loss X 1.40 for all other systems
1/25/2024C:\Users\kylem\Desktop\C3 Calculator.xlsm 8/7/2026
DRAWN BY: BRUCE RUSTAD
EXISTING & PROPOSED SITE PLAN
DATE: 04/18/26
SCALE: 1" =20'-0" ON 11" x 17" PAPERSCALE: 1" =10'-0" ON 22" x 34" PAPER
NOTES:
1. DURING CONSTRUCTION, THE RUN OFF WILL BE CONTROLLED WITH
ADJACENT PROPERTY.SILT FENCES AND SHALLOW SWALES TO PROTECT THE
PROTECTOR INSTALLED PER WSDOT DETAIL 1-40.20-002. THE STREET STORM WATER CATCH BASIN WILL HAVE A STORM DRAIN INLET
3. STREET AND DITCHES WILL BE CLEANED DAILY OF ERISION RUN-OFF IF ANY.
4. BEFORE CONSTRUCTION BEGINS, A SITE WALK WILL TAKEPLACE TO IDENTIFY THE CONDITION OF THE STREET, CURB & GUTTER.ALL BROKEN AREAS WILL BE REPLACED TO THE CITY'S APPROVALPRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
PARCEL #: P33069 & P56650
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITHBUILDER TO VERIFY ALL DIMENSIONS
7,066 SQ. FT.
25.9%
PERCENT OF COVERAGE
LOT AREA (BOTH LOTS)HOUSE
PERCENT OF COVERAGE
EXISTING
EXISTING IMPERVIOUS AREA
PERCENT OF IMPERVIOUS 56%
DRIVEWAY & SIDEWALKS
5. TIE-INTO CITY WATER & SANITARY SEWER.
DRAWING INDEX:
1. PROPOSED SITE PLAN2. EXISTING & NEW ELEVATIONS
4. EXISTING & NEW FOUNDATION PLAN
5. EXISTING & NEW ROOF PLAN6. SECTIONAL DETAILS
3. EXISTING & NEW FLOOR PLANS
1
1 of 7
ZONED R-3
LOT AREA
TOTAL IMPERVIOUS 3,964 SQ. FT.
7. EXCESS CONCRETE TO BE REMOVED
1,238 SQ. FT.
37TH STREET
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
59.99'N 89d 56' 34" E
59.99'N 89d 56' 34" E
VACATED ALLEY
SEWER
EXISTING SITE PLAN
EXISTING HOUSE
EXISTING GARAGE
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
PO
R
C
H
WOODEN FENCE
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
TREE
BUSH
BUSH
BUSH
TREE
7.6'
3.8'
12./7'
REMOVE THISPORTION
REMODEL THISPORTION
GRASS
GRAVEL
GRASS
GRASS
37TH STREET
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
11
8
.
0
0
'
N
0
d
0
3
'
3
1
"
E
59.99'N 89d 56' 34" E
59.99'N 89d 56' 34" E
SEWER
CITY WATER
PROPOSED SITE PLAN
EXISTING HOUSE
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
TREE
BUSH
BUSH
BUSH
TREE
3.8'
GRASS
GRASS
GRASS
EXISTING GARAGEREMODELED INTO AN ADU
PERCENT OF COVERAGE
PERCENT OF COVERAGE
NEW
GARAGE 600 SQ. FT.TOTAL 1,838 SQ. FT.
892 SQ. FT.ADUTOTAL 2,130 SQ. FT.
30%
HOUSE GARAGE 1216 SQ. FT.
NEW IMPERVIOUS AREA
PERCENT OF IMPERVIOUS 49 %
DRIVEWAY & SIDEWALKS
LOT AREA
TOTAL IMPERVIOUS 3,473 SQ. FT.
HOUSE 892 SQ. FT.ADU
PATIO 127 SQ. FT.
5.79'
10.71'
25.6'
4.6'
20'
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
DOWNSPOUT
7. BRACE WALL PLAN
25.6'
20'
EXISTING
DOWNSPOUTEXISTING
DOWNSPOUTEXISTING
4" SOLID PVCNEW
TO INTO EXISTINGDRAINAGE SYSTEM
4" SOLID PVCEXISTING
DOWNSPOUTNEW
DOWNSPOUTNEW
BMP C233SILT FENCE
BMP C233SILT FENCEBMP C233SILT FENCE
9' x 14'PATIO
CO
N
C
R
E
T
E
B
O
R
D
E
R
6x6 BORDER
TREE
TREE
GRAVEL
GRAVEL
GR
A
V
E
L
GRASS
FL
O
W
E
R
B
E
D
CITY WATERNEW
6x6 BORDER
TREE
TREE
FL
O
W
E
R
B
E
D
REV. #1 05/13/26
P33069
P56650
7,066 SQ. FT.LOT AREA (BOTH LOTS)HOUSE 1,238 SQ. FT.
GRAVEL AREA 910 SQ. FT.
600 SQ. FT.1,238 SQ. FT.7,066 SQ. FT.
7,066 SQ. FT.1,238 SQ. FT.
1,216 SQ. FT.
600 SQ, FT.
1238 SQ, FT.
(ORINANCE NO.475)(ORINANCE NO.475)VACATED ALLEY
127 SQ, FT.
Legal Description P33069: TAX 32AAA E 60 ft OF FOL TR BAAP 520 ft. E &
4127 FT. N OF SW C GOVERNMENT LOT 2, SECTION 30. TOWNSHIP 35NORTH, RANGE 2 EAST, W.M. TH E 482.3 FT TH S 100 FT. TH W 482.3 FT TH N
100 FT TPB LESS E 60 FT. & TAX 32AAB.
Legal Description P56650: FRACTIONAL LOTS 17 AND 18. BLOCK 12, BEALE'S
MAPLE GROVE ADDITION TO THE CITY OF ANACORTES, ACCORDING TOPLAT THERE OF RECORDED IN VOLUMN 2 OF PLATS. PAGE 19, RECORDS OF
SKAGIT COUNTY, WASHINGTON. TGW S1/2 OF VAC ALLEY
NOTE: Lots will be merged byconstruction. Staff encouragesthe property owner to combinethe two parcels with SkagitCounty in order to have onetax parcel in the future.
CO
N
C
R
E
T
E
D
R
I
V
E
W
A
Y
GRAVEL GRAVELGRAVELGRAVEL
CITY WATER
THREE OFF STREET PARKING
TWO ON STREET PARKING
THREE OFF STREET PARKING
TWO ON STREET PARKING
CITY WATEREXISTING
SEWEREXISTING
SEWERNEW
EXISTING
DRAINAGEDOWNSPOUTEXISTING
6. TIE-INTO EXISTING DOWNSPOUT DRAINAGE
22" x 34" PAPER SIZE --- SCALE IS 1/4" = 1'11" x 17" PAPER SIZE --- SCALE IS 1/8" = 1'
DRAWN BY: BRUCE RUSTAD
EXISTING & NEW ELEVATIONS
DATE: 04/18/26
PARCEL #: P33069
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITH
BUILDER TO VERIFY ALL DIMENSIONS
2
2 of 7
ZONED R-3
GRADEGRADE
EXISTING SOUTH ELEVATION
GRADE
GRADE
EXISTING WEST ELEVATION
EXISTING NORTH ELEVATION
GRADE GRADE
GRADE
GRADE
EXSTING EAST ELEVATION
GRADE
GRADE
NEW SOUTH ELEVATION
GRADE
GRADE
NEW EAST ELEVATION
GRADE
GRADE
NEW WEST ELEVATION
GRADE GRADE
NEW NORTH ELEVATION
12
4
NEW HARDIE- BOARD SIDING
5/4x4 TRIM
5/4x4 TRIM8'-6"
REMOVE THIS PORTION OF GARAGE
22" x 34" PAPER SIZE --- SCALE IS 1/4" = 1'11" x 17" PAPER SIZE --- SCALE IS 1/8" = 1'
DRAWN BY: BRUCE RUSTAD
EXISTING & NEW FLOOR PLANS
DATE: 04/18/26
PARCEL #: P33069
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITH
BUILDER TO VERIFY ALL DIMENSIONS
3
3 of 7
ZONED R-3
EXISTING FLOOR PLAN
LIVING
EXISTING GARAGE
22'
24'
12'12'
22'
12'
10'
0 04 x 4 XO
EGRESS
BATH
50 cfm
FAN
REFR.
FA
N
16
0
c
f
m
RA
N
G
E
EX
H
A
U
S
T
KITCHEN
DINING
0
0
3
x
3
X
O
30
3
0
1
x
5
P
I
C
3
0
1
x
5
P
I
C
BEDROOM
NEW FLOOR PLAN
892 SQ. FT. LIVING AREA
26
26
6
0
2
x
1
X
O
CLOSET
BEDROOM
DW
6 03 x 3 XO
06
S
L
D
G
.
G
L
.
D
R
.
5 DBL. DR.6
W/D
CLOSET
0
0
4
x
4
X
O
EG
R
E
S
S
4'16'4'
12'
24'
34'
ON DEMANDHOT WATER
6 BI-PASS DR.0
6 BI-PASS DR.0
2
P
K
T
.
D
R
.
6
TU
B
SH
O
W
E
R
EXISTING 2x4 WALLSALL
8'-6" CEILING
STORAGE8'-6" CEILING
24'
44'
34'
10'REMOVE GARAGE DOOR& NEW WALL TO BE 2x6's@ 16" CTRS.
WALL INEXISTING WINDOW
WALL INEXISTING DOOR
WALL INEXISTING WINDOW
PORTION OF BUILDINGREMOVE EXISTING BACK
24'
22'
44'
22'
18'-5"
3'-7"
22'
8'
2'-612"
11'-512"
8'-1112"3'-6"3'-912"5'-9"
3'-912"7'-9"
20'-912"
2'-412"
10'-10"
EXISTINGHOUSE4'-6"
6'-6"
MAKE EXISTING 2x4 WALL TO2x6 @ 16" CTS STUD WALL
7'-10" CEILING HEIGHT
FIRE WALL 5/8" Type X REMOVE ALL EXISTINGSHINGLE SIDINGNEW SIDINGHARDIE-PLANK
EXISTING 2x4 STUDSNEW 2x6 STUDS @ 16" CTRS.
7'-10" CEILING HEIGHT
2'
WINDOW SCHEDULE
SIZE FRAME DESCRIPTIONNO.
A
B
AMOUNT
2 U factor ( E .22)
2
4'-0" x 4'-0"
1'-3" x 5'-0"
COMPOSITE
C 1 3'-6" x 3'-0"
AMOUNT DESCRIPTIONSIZE
DOOR SCHEDULE
3
2
1
2'-6" x 6'-8"x 1-3/8"
2
1
4
1
3'-0" x 6'-8"x 1-3/4"
PICTURE, DBL. GLAZEDCOMPOSITE
COMPOSITE
EXTERIOR 1/2 LITE DOOR
2 6'-0" x 6'-8"x 1-3/8" BI-PASS DOOR
* ALL EXTERIOR WALLS TO BE INSULATED R-21
CO DETECTOR
SMOKE DETECTORSD
SHEATHED w/ 1/2" GYP. BD. BOTH SIDES
* ALL INTERIOR WALLS TO BE FRAMED w/ 2x4 @ 16" CTRS. && SHEATHED w/ 1/2" GYP. BD. INTERIOR.
* ALL EXTERIOR WALLS TO BE FRAMED w/ 2x6 @ 16" CTRS. &
EXCEPT AS NOTED.
NOTES:
TOTAL CREDITS 5.0 Credits
2021 ENERGY CREDITS PER WSECC Table 406.2
LESS THAN 1500 SQ. FT. 5 CREDITS
1.1.1 Prescriptive Building Envelope 0.5 Credit
* FENESTRATION ADU AREA IS 120.6 SQ. FT.
2'-6" x 6'-8"x 1-3/8"INTERIOR DOOR
SLIDER, DBL. GLAZED, EGRESS
U factor ( E .22)
2.
3.5 Mini-split Heat Pump 1.5 Credit3.2.1 Air Leakage Control and Efficient Ventilation
1.0 Credit
5 1. Inverted-driven ductless mini-split heat pump 2.0 Credit
4.
SHEATHED w/ 7/16" OSB & 15# BUILDING PAPER EXTERIOR
U factor ( E .22)POCKET DOOR SLIDER, DBL. GLAZED
D 1 3'-0" x 3'-0"COMPOSITE U factor ( E .22)SLIDER, DBL. GLAZED
E 1 2'-6" x 1'-0"COMPOSITE U factor ( E .22)SLIDER, DBL. GLAZED
ALARMCO
A
A
B
B
C
D
E
1
2
2
3
4
4
5
5 1 6'-2" x 6'-8"x 1-3/8"DOUBLE DOOR
6
6 1 6'-0" x 6'-8"SLIDING GLASS DOOR
SD
SD
AL
A
R
M
CO
2'-6"
2'-6"
8'-10"
6'
4'
7'-2"
5'-5"
14'-9"
3'-8"
5'-6"
16'-6"
4'-3"
12'12'
6'6'
4'
CS
-
W
S
P
CS-WSP
CS
-
W
S
P
CS
-
W
S
P
CS-WSP
CS
-
W
S
P
EXISTINGHOUSE4'-6"
6'-6"
7'-10" CEILING HEIGHT7'-10" CEILING HEIGHT
7'-10" CEILING HEIGHT
7'-2"
7'
4'
14'-10"
CS-WSP
1 HOUR RATED
FIRE WALL 5/8" Type XGYP. BD. BOTH SIDES1 HOUR RATED
GYP. BD. BOTH SIDES
REV.#1 07/07/26
CS-WSP
CS
-
W
S
P
CS
-
W
S
P
CS
-
W
S
P
CS-WSP CS-WSP
CS
-
W
S
P
CS
-
W
S
P
22" x 34" PAPER SIZE --- SCALE IS 1/4" = 1'11" x 17" PAPER SIZE --- SCALE IS 1/8" = 1'
DRAWN BY: BRUCE RUSTAD
EXISTING & NEW FOUNDATION PLANS
DATE: 04/18/26
PARCEL #: P33069
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITH
BUILDER TO VERIFY ALL DIMENSIONS
4
4 of 7
ZONED R-3
EXISTING GARAGE
NEW FOUNDATION PLAN
EXISTING STORAGE
22'
4" THICK CONCRETE SLABSLOPING TOWARDS GARAGE DOOR
4" THICK CONCRETE SLAB
17'
12'
6" STEM WALL w/ FOOTING
6" STEM WALL w/ FOOTING
REMOVE FOUNDATION & CONCRETE SLAB
EXISTING FOUNDATION
REMOVE CONCRETE STEP
22'
22'
22'
2'22'
8'
14'
7/16" OSB SHEATHING
(2) HORIZ #4 REBAR (CONT.)
30 TIMES THE REBAR DIA. w/
MIN. TWO SETS OF TIES
SPLICE LENGTH TO BE
@ 48" CTRS.VERTICAL #4 REBAR
w/ STD. HOOK
LOCATED NOT MORE THAN 12" FROM ENDS
ON 4'-0" CENTERS
GRADE
3"x3"x1/4" GALV. PL. WHR.1/2" X 10" A-BOLTS
HORIZ #4 REBAR (CONT.)IN UPPER 1'
6"
12"
8"
8d @ 6" CTRS.
2x6 STUDS @ 16" CTRS. WALL
OR LESS THAN SEVEN BOLT DIA. 3-1/2"FROM EACH END OF PIECE
MIN. OF 2 BOLTS PER PIECE
FILTER FABRIC
DRAIN ROCK
IMPERVIOUS UPPER 1'
FOUNDATION BACK FILL
HORIZONAL #4 REBAR @ 24" CTRS.
30 TIMES THE REBAR DIA. w/MIN. FOUR SETS OF TIES
SPLICE LENGTH TO BE
NOT TO SCALE
6" STEM WALL EVENLY SPACED ALONG SPLICE
6" MIN.
2" EXTRUDED POLYSTYRENER 204" THK. CONC. SLAB w/ 6x6 WIRE MESH
6 MIL BLACK VISQUEEN w/
4" PVC GUTTER DRAIN PIPEGRAVITY
18"
12"
GRADE
SLOPE 1/4" per 12"
(2) HORIZ #4 REBAR (CONT.)
30 TIMES THE REBAR DIA. w/MIN. TWO SETS OF TIES
SPLICE LENGTH TO BE
EVENLY SPACED ALONG SPLICE
NOT TO SCALE
PATIO SECTIONAL
4" CONC. SLAB
6" STEM WALL(TYP)
4" THK.
THICKENED EDGE
(3) #4 x 12" REBARDRILLED & GLUED INTOEXISTING STEM WALL
(3) #4 x 12" REBARDRILLED & GLUED INTOEXISTING STEM WALL
EXISTING 6" STEM WALL
(2) #4 HORIZ. REBAR
12'
8'-3"
DRILED INTOEXISTING STEM WALL
#4 VERT. REBAR18" CTRS. DRILLED INTOEXISTING FOOTING
REMOVE CONCRETE STEP
EXISTING ON-EVEN CONCRETE SLAB
2" EXTRUDED POLYSTYRENER 20
6 MIL BLACK VISQUEEN w/
4" THK. CONC. SLAB w/ 6x6 WIRE MESH
NEW
NEW
12'
22'
10'
12'
24'
2" EXTRUDED POLYSTYRENER 20
4" THK. CONC. SLAB
6x6 WIRE MESH
6 MIL BLACK VISQUEEN w/
TIE-INTO EXISTING DRAINAGE
PATIO
ADU FOUNDATION
NEW FOUNDATION
FOUNDATION
FOUNDATION
FOUNDATIONEXISTING
CONC. SLAB
22" x 34" PAPER SIZE --- SCALE IS 1/4" = 1'11" x 17" PAPER SIZE --- SCALE IS 1/8" = 1'
DRAWN BY: BRUCE RUSTAD
EXISTING & NEW ROOF PLANS
DATE: 04/18/26
PARCEL #: P33069
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITH
BUILDER TO VERIFY ALL DIMENSIONS
5
5 of 7
ZONED R-3
EXISTING ROOF PLAN
LIVING
EXISTING GARAGE BATH
50 cfm
FAN
REFR.
FA
N
16
0
c
f
m
RA
N
G
E
EX
H
A
U
S
T
KITCHEN
DINING
BEDROOM
NEW ROOF PLAN
CLOSET
BEDROOM
DW
W/D
CLOSET
EXISTINGHOUSE
TU
B
SH
O
W
E
R
STORAGE
PORTION OF BUILDINGREMOVE EXISTING BACK
EXISTINGHOUSE
4x8 #2DF HDR.
4x
1
0
#
2
D
F
H
D
R
.
4x
8
#
2
D
F
H
D
R
.
4x
8
#
2
D
F
H
D
R
.
4x
8
#
2
D
F
H
D
R
.
4x
1
0
#
2
D
F
H
D
R
.
EXISTING BEAM
22'
22'
4/12 PITCHENGINEERED HIP TRUSSES
@ 24" CTRS.
EXISTING 4/12 PITCHED ROOFSTICK FRAME OVER
@ 24" CTRS.
NEW 4/12 PITCHED ROOF
6'
EXISTING 4/12
STICK FRAME OVER
NEW
12'
22'
12'
12'
16'
12'
10'
2'
24'
PITCHED ROOF
2x6 BACKING
4/12 PITCHEXISTING HIP TRUSSES
@ 24" CTRS.
4/12 PITCHEXISTING HIP TRUSSES
@ 24" CTRS.
12'-9"
8'
13'-5"
2'
GABLE PORCH ROOFSTICK FRAME
22" x 34" PAPER SIZE --- SCALE IS 1/2" = 1'11" x 17" PAPER SIZE --- SCALE IS 1/4" = 1'
DRAWN BY: BRUCE RUSTAD
SECTIONAL DETAILS
DATE: 04/18/26
PARCEL #: P33069
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITH
BUILDER TO VERIFY ALL DIMENSIONS
6
6 of 7
ZONED R-3
ENGINEERED HIP TRUSSES4/12 PITCH@ 24" CTRS.
ASPHALT 3 TAB SHINGLES15# FELT
USE METAL "H" CLIPS AT UNSUPPORTED EDGES.FACE GRAIN PREPENDICULAR TO SUPPORTS.INTERMEDIATE SUPPORTS. EDGES & 8d @ 10" CTRS. @ w/ 8d @ 6" CTRS. AT ALL SUPPORTED7/16" OSB SHEATHING NAILED
R-60 INS.
R-21 INSULATION
SEE ELEVATIONS FOR SIDING
VAPOR BARRIER2x6 @ 16" CTRS. WALL
& 8d @ 12" CTRS. AT w/ 8d @ 6" CTRS. AT PANEL EDGES7/16" OSB. BLOCK ALL PANEL EDGES &
INTERMEDIATE FRAMING1/2" GYP.BD. BOTH SIDES
2x4 @ 16" CTRS. WALL
2" EXTRUDED POLYSTYRENE R-20
4" CONCRETE SLABw/ 6x6 WIRE FABRIC& 6 MIL VISQUEENw/ 6x6 WIRE FABRIC & 2" EXTRUDED POLYSTYRENEPOUR 4" THK. CONCRETE SLAB
OVER EXISTING 4" CONCRETE SLAB
EXISTING 4" CONCRETE SLAB
2x4 BLOCKING
METAL FLASHING
AIR FLOW
METAL GUTTER
FASCIA BOARD
4/12 PITCH ENGINEERED TRUSS
RIDGE VENT
12
4
NEW CONCRETEWHERE GARAGE DOOR REMOVED
SIMP. HURR. TIESEACH TRUSS
7'-10"
3/4" CRUSTED STONE OR EQUAL FILL
REV. #1 CHANGED CEILING INSULATION TO R-60
22" x 34" PAPER SIZE --- SCALE IS 1/4" = 1'11" x 17" PAPER SIZE --- SCALE IS 1/8" = 1'
DRAWN BY: BRUCE RUSTAD
BRACE WALL PLAN
DATE: 04/18/26
PARCEL #: P33069
ADDRESS: 808 37th STREET
JUSTIN PARKINS ADU
Xrefld: 350230-0-078-0008PLUMBING TO COMPLY WITH THE IRC 2021 BUILDING CODES
2021 UNIFORM PLUMBING CODE
BUILDING TO COMPLY WITH THE 2021 WASAHINGTON STATE ENERGY CODE CONSTRUCTION NEEDS TO COMPLY WITH
BUILDER TO VERIFY ALL DIMENSIONS
7
7 of 7
ZONED R-3
LIVING
BATH8' CEILING
50 cfm
REFR.
FA
N
16
0
c
f
m
RA
N
G
E
EX
H
A
U
S
T
KITCHEN
DINING
BEDROOM
CLOSET
BEDROOM
DW
W/D
CLOSET
TU
B
SH
O
W
E
R
CS-WSPCS-WSP
CS
-
W
S
P
CS
-
W
S
P
CS-WSP
CS
-
W
S
P
CS-WSP
CS-WSP
CS
-
W
S
P
CS
-
W
S
P
CS
-
W
S
P
4'
4'
4'
4'
4'
CS
-
W
S
P
4'
4'4'
4'4'
4'
4'
4'
A B
1 1
CS
-
W
S
P
4'
2 2
A
22'-6"
20'-9"
3 3
B
18'
DOWN
PANELSWITHHOLD BRACING
REQUIREDTOTAL
LENGTH
OK11.20
STATUSPROVIDED
BRACINGLENGTHREQUIREDWALL LINEBRACED
LENGTHBRACINGMETHODLINE
BRACEDWALL
1.0
1.0
LETTERED NUMBERED
1.0
1.0
WALL LINESWALL LINESSDS DIRC Table R602.10.3(4)
STORY HEIGHT
WALL DEAD LOAD
SEIAMIC FACTOR TOTAL
1.2 1.2
1.21.2
ROOF & CEILING DEAD LOAD
SEISMIC CALCULATIONS2
TOTALFACTORSEISMIC
INTERMITTENT SHEATHING BRACED WALL LINES
GB = 1/2" GYPSUM BOARD w/ 7" NAIL OR SCREW ON CENTER SPACING FIELD & EDGESWSP = WSP (WOOD STRUCTUAL PANEL) 6" NAILING ON CENTER EDGE & 12" NAILING ON CENTER FIELD
B
WALLBRACED
LINE METHODBRACING SPACING
BRACEDWALL LINE REQUIREDBRACING HOLDWITHPANELS
DOWN
TOTALREQUIRED
BRACING LENGTH
BRACING
PROVIDED
1 CS-WSP
2
STATUS
A
WALL HEIGHT
ROOF EAVE TO RIDGE HEIGTH
EXPOSURE CATEGORY
IRC Table R602.10.3(2)115 MPH
NUMBER OF BRACE WALL LINES
WIND FACTOR TOTAL
WALL LINES WALL LINES
1.0
1.0
NUMBERED LETTERED
1.0
1.0
.95.95
WINDFACTORTOTAL
WIND CALCULATIONS
MAIN FLOOR BRACE WALL PLAN
1.30
OK1.24
B
A OK
OK
OK
OK
OK12
12
1.24
LENGTH
1
0
0
1
3
1.20 OK2
22.50
1.24
1.24 0 OK
GB GB
OK3
22.50
.95
.95
4.00
4.00
3.80
3.80
1.20
1.20
20.75
18.00
18.00
3.67
1.0
.95
5.90
4.55
7.32
3.20 3.96
12'
GB
12
8
8 1.20
1
0
0
1
0
22.50
22.50
20.75
18.00
18.00
4.15 4.98
4.50 5.40
4.50 5.40
3.60 4.32
12
12
12
8
8
7.20 8.64
CS-WSP
4'
CS
-
W
S
P
CS-WSP
CS-WSP
CS-WSP
CS-WSP
CS-WSP
CS-WSP
CS-WSP REV. #1 07/07/26
Small Site Construc�on SWPPP (002) Updated 5/22/5025 page 1 of 6
Permit #:
Received by:
Small Site Construction SWPPP
City of Anacortes Stormwater · 904 6th Street · Anacortes, WA 98221
Stormwater: 360-630-1037
General Information
Project Name Parcel Size acres
Project Address
Property Owner Phone
Site Contact Phone
Project Description
Describe the nature and purpose of the construction project. Include the total size of the area, any increase in existing impervious area; the total area expected to be disturbed by clearing, grading, excavation or other
construction activities, including off-site borrow and fill areas; and the volumes of grading cut and fill that are proposed.
Erosion control lead or responsible party
Phone
Engineer/Firm Phone
Site Conditions
Adjacent Areas: See the site plan, drainage plan, and construction drawings approved for the associated permit.
Critical areas: See the critical areas site plan approved for the associated permit.
REQUIRED before SWPPP can be approved:
1.Attach a copy of your stormwater site plan submitted with your building/grading permit application and attach
pictures.
2.Add a map of where your stormwater goes from your project to the discharge site.
3.Stormwater site plan shall list all BMPs for inspectors of construction site.
REQUIRED before final can be approved:
1. BMP T5.13: Post-Construction Soil Quality and Depth
BLD-2026-0336
A.Esterholt
Stormwater Review
PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT
Mailing Address: P.O. Box 547, Anacortes, WA 98221
Office Location: 904 6th Street, Anacortes WA 98821
Phone: (360) 293-1901
Weekly Erosion Control Self-Inspection Reports
All sites that have a Stormwater Pollution
Prevention Plan #2, 1-5 or 1-9 are required to
submit a weekly erosion control/BMP monitoring
inspection report through the citizen portal.
These reports can be found on the city website
and through the link on the submittals tab in the
permitting customer portal.
Turning in the
weekly report
consistently will
help keep your
project on
schedule and
avoid unnecessary
delays due to
cancelled
inspections.
Erosion-Control-Inspection-Form--Sites-Less-Than-One-Acre-fillable-PDF (anacorteswa.gov)
Stormwater Site Inspection Form (anacorteswa.gov) (For larger sites)
We appreciate your assistance in keeping our documentation up to date.
Just complete the fillable PDF, save it, and
then upload it with the blue upload tab.
Small Site Construc�on SWPPP (002) Updated 5/22/5025 page 2 of 6
Small Site Construc�on SWPPP (002) Updated 5/22/5025 page 3 of 6
Best Management Practices Illustration
Turn the page to see information corresponding to each numbered circle below.
About this Pollution Prevention Plan
This is Anacortes’s Small Site Construction Stormwater
Pollution Prevention Plan (“Construction SWPPP”)
intended to ensure your construction project minimizes
erosion and does not contribute pollution, including
sediment, to stormwater. This SWPPP is primarily
intended for projects under 2,000 sq ft.
This plan uses certain Best Management Practices
(“BMPs”) from the Stormwater Management Manual.
Some detailed descriptions are included; the remainder
and additional information are available at
https://fortress.wa.gov/ecy/ezshare/wq/Permits/
Flare/2019SWMMWW/2019SWMMWW.htm#Topics/
FrontCover.htm?TocPath=2019%2520SWMMWW%
257C_____0
The listed BMPs are the minimum necessary; if erosion
occurs, you must add additional BMPs as necessary
to control it.
You should include your Construction SWPPP in your
contract with your builder. You must keep a copy of this
SWPPP on the construction site or within reasonable
access to the site for construction and inspection personnel at all times.
Property owners and contractors are responsible for
ensuring all aspects of BMPs are followed, including
those not shown on the detail sheets. This Construction
SWPPP should be considered a living document and
must be updated as needed to reflect site conditions.
Preserve Vegetation/Mark Clearing Limits
Before any land disturbance, including clearing and
grading, clearly mark all clearing limits, sensitive areas
and their buffers, and trees that are to be preservedwithin
the construction area. Retain natural vegetation in an
undisturbed state to the maximum extent practical. Use
these BMPs:
•C101 to preserve natural vegetation
•C102 to establish buffer zones around important
vegetation you want to save
•C103 High Visibility Fencing to mark the
boundaries of your buffers
•C233 Silt Fence to ensure sediment doesn’t leave
the site
Establish Construction Access
Construction vehicles can damage or compact
soils, create sediment pollution, or track sediment
onto public roads.
•All equipment and vehicles that access the
construction area must use an existing driveway or a
stabilized construction entrance.
•Use BMP C105 Stabilized Construction Entrance
wherever traffic will be entering or leaving a
construction site if paved roads are within 1,000 ft of
the site. Construct a 12-inch thick pad of 4-inch to 8-
inch quarry spalls, a 4-inch course of asphalt treated
base, or use existing pavement. Place a separation
geotextile under the spalls to prevent fine sedimentfrom pumping up into the rock pad. Install the
construction entrance prior to any vehicles entering
the site, at the location shown on the site plan.
Create only one construction entrance per site.1
2
1b
1b
1b
2
1a
4
7
9a
9b
5
9b
Small Site Construc�on SWPPP (002) Updated 5/22/5025 page 4 of 6
•Use BMP C103 High Visibility Fencing to restrict
traffic to the construction entrance.
•Remove any sediment that is tracked onto pavementby shoveling or street sweeping and remove the
collected sediment or stabilize it on site.
Control Flow Rates (not shown)
Stormwater on a cleared site can create significant
flows that can damage downstream properties.
Protect properties and waterways downstream of the
project site from erosion and the associated discharge of
turbid waters. If your project is required to control flow
rates, you must use the following BMPs as shown on the
approved site plan:
•C203 Water Bars
•C209 Outlet Protection
•C235 Straw Wattles
Install Sediment Controls
When land is cleared of vegetation, stormwater can
pick up sediment, a pollutant. BMPs can prevent
sediment from leaving the site.
You must install sediment controls before land
disturbance to effectively minimize and control the
discharge of pollutants and sediments.
Use and properly install BMP C233 Silt Fence. You
must bury the filter fabric as shown in the diagram in
order for the BMP to be effective. You must repair the silt
fence if it is damaged.
Consider the following additional BMPs:
•C231 Brush Barrier
•C232 Gravel Filter Berm
•C234 Vegetated Strip
•C235 Straw Wattles
Note that C230 Straw Bale Barrier is no longer an
approved BMP.
Stabilize Soils
Leaving soils devegetated or exposed needlessly
creates erosion and sediment problems.
•Stabilize all exposed soils whenever constructionwork will stop for more than two days at a time during
the wet season (October 1 to April 30) or 7 days the
rest of the year (the dry season).
•Stabilize all exposed soils at the end of the shift
before a holiday or weekend.
•Stabilize all exposed soils with either vegetation, matcoverings, mulching, or in those areas to be paved, a
compacted base material.
•Use BMP C123 Plastic Covering over all stockpiles
with plastic or burlap if left unworked. Place sand-
filled burlap or geotextile bags every 3 to 6 ft along
seams and tie them together with twine to hold them
in place.
•If you excavate soil for the foundation, backfill that
soil against the foundation and grade it to drain away
from the building. Once the disturbed landscape
areas are graded, you must seed or sod the grass
areas.
Consider the following additional BMPs:
•C120 Temporary and Permanent Seeding
•C121 Mulching
•C122 Nets and Blankets
•C124 Sodding
•C125 Topsoiling/Composting
•C131 Gradient Terraces
•C140 Dust Control
Protect Slopes (not shown)
Slopes can be especially vulnerable to erosion, but
BMPs can mitigate sediment problems.
Design and construct cut-and-fill slopes to minimize
erosion. Use the following practices:
•Reduce continuous length of slope with terracing and
diversions
•Reduce slope steepness
•Roughen slope surfaces
•Use BMP C123 Plastic Covering over all exposed
slopes
•Use BMP C120 Temporary and Permanent Seeding
as soon as possible on exposed slopes
Manage off-site stormwater (run-on) separately from
stormwater generated onsite. Divert off-site stormwater
or groundwater away from slopes and disturbed areas
with interceptor dikes, pipes, or swales.
You may not create cut slopes over 4 feet high or slopes
steeper than 2 feet horizontal to 1 foot vertical. Fill
slopes may not exceed 4 feet high or 3 feet horizontal to
1 foot vertical. Slopes that exceed these criteria require
engineering.
Consider the following additional BMPs:
•C121 Mulching
•C122 Nets and Blankets
•C124 Sodding
•C203 Water Bars
•C208 Triangular Silt Dike (Geotextile‐Encased Check
Dam
Protect Drain Inlets
Storm drains are designed to collect and transport
clean stormwater, not water contaminated with
sediment or other pollutants. Storm drain inlets
must be protected so that runoff does not enter the
3
4
5
6
7
Small Site Construc�on SWPPP (002) Updated 5/22/5025 page 5 of 6
stormwater system without first being filtered or
treated or both.
•Use BMP C220 Storm Drain Inlet Protection to
protect all proposed and existing storm drain inletsduring construction so that stormwater runoff does
not enter the stormwater conveyance system without
first being filtered or treated (or both) to remove
sediment or other pollutants.
•Clean or remove and replace inlet protection devices
when sediment has filled one-third of the available
storage (unless a different standard is specified by
the product manufacturer).
•Keep all approach roads clean.
•Do not allow sediment and street wash water to enter
storm drains without treatment.
Stabilize Channels and Outlets
Stormwater channels and outlets can themselves
erode unless stabilized with rock or other armoring.
Design, construct, and stabilize all on-site conveyance
channels to prevent erosion as needed. Use BMP C209
Outlet Protection to provide stabilization, including
armoring material adequate to prevent erosion of outlets,
adjacent streambanks, slopes, and downstream reaches
at the outlets of all conveyance systems.
Consider the following additional BMPs:
•C122 Nets and Blankets
•C202 Channel Lining
Control Pollutants
Waste materials, demolition debris, and other
pollutants that occur onsite during construction can
contaminate the stormwater system unless
managed. Cement and related products can modify
the pH of stormwater.
Provide cover, containment, and protection from
vandalism for all chemicals, liquid products, petroleum
products, and other materials that have the potential to
pose a threat to human health or the environment.
Anytime you pour concrete, perform washout of the
concrete trucks following BMP C154 Concrete Washout
Area at designated washout areas only. Locate washout
areas at least 50 ft from sensitive areas such as storm
drains, open ditches, or water bodies, including
wetlands.
Clean contaminated surfaces immediately following any
spill incident. Apply fertilizers and pesticides in a manner
and at rates that will not result in loss of chemical via
stormwater runoff.
Use the following additional BMPs:
•C151 Concrete Handling
•C152 Sawcutting and Surfacing Pollution Prevention
•C153 Material Storage, Delivery, and Containment
Control De-Watering (not shown)
De-watering water extracted from foundations,
vaults, or trenches, has similar characteristics to
stormwater runoff at the site and can cause the
same impacts unless properly managed.
You may discharge clean, non-turbid de-watering, such
as well-point ground water, to systems that are
tributaries to, or directly into, surface waters if the de-
watering flow does not cause erosion or flooding or
interfere with the operation of the stormwater system.
Use the following BMPs:
•C220 Storm Drain Inlet Protection
•C236 Vegetative Filtration
Maintain BMPs (not shown)
All temporary and permanent erosion and sediment
control BMPs must be maintained and repaired as
needed to assure continued performance of their
intended function.
During the dry season, inspect sediment control BMPs
weekly or after a runoff-producing storm event. During
the wet season, inspect BMPs daily. Use BMP C150
Materials on Hand to ensure you are ready for a heavy
rain.
All temporary erosion and sediment control BMPs must
be removed within 30 days after the City determines that
the site is stabilized or after the temporary BMPs are no
longer needed. Trapped sediment must be removed or
stabilized on site. Disturbed soil areas resulting from
removal of BMPs or vegetation must be permanently
stabilized.
Manage the Project (not shown)
Phasing a project, especially when revegetation
occurs as part of each phase, can help prevent the
transport of sediment from the site.
•Fully implement this Construction SWPPP at all
times.
•Modify this Construction SWPPP whenever there is a
change in design, construction, operation, or
maintenance at the construction site that has or could
have a significant effect on the discharge of
pollutants to waters of the state.
•Inspect, maintain, and repair all BMPs as needed to
ensure continued performance of their intended
function.
8
9
10
11
12
Small Site Construc�on SWPPP (002) Updated 5/22/5025 page 6 of 6
Protect Low-Impact Development BMPs
Low-Impact Development techniques can be
damaged if they are compacted or accumulate
sediment during construction.
If there are any Low-Impact Development BMPs planned
for the site:
•Use BMP C103 High Visibility Fence to exclude all
construction and foot traffic from the infiltration, bio-
retention, or rain garden areas.
•Protect all infiltration areas or bio-retention and rain
garden BMPs from sedimentation through installation
and maintenance of erosion and sediment control
BMPs on portions of the site that drain into those
areas.
•Use BMP C233 Silt Fence or C234 Vegetated Strip
to control and avoid introducing sediment onto
permeable pavements. Bury the bottom of the filter
fabric at least 4 inches below the ground surface.
Backfill and tamp soil in place over the buried
portion of the filter fabric, so that no flow can
pass beneath the fence and scouring cannot
occur. Drive or place the fence posts into the ground
at least 18 inches. A 12-inch minimum depth is
allowed if topsoil or other soft subgrade soil is not
present and 18 inches cannot be reached.
•If pavements are fouled with sediments or no longer
pass an initial infiltration test, clean them using
procedures from the Stormwater Manual or the
manufacturer’s procedures.
Consider the following additional BMPs:
•C102 Buffer Zones
•C208 Triangular Silt Dike
•C231 Brush Barries
****************************************************************
I acknowledge that I have read the information
presented to me and agree to abide by the BMP
rules.
______________________ _____________________
Printed name Signature
______________________
Date
****************************************************************
13