HomeMy WebLinkAboutPermit File BLD-2018-0008 716 37th Street (4)BMP C233
"m
m
SMALE GARAGE
716 37TH STREET
ANACORTES, WASHINGTON
PARCEL # P56670
ZONING DESIGNATION: R3
NEW CONSTRUCTION OF DETACHED GARAGE. EXISTING
GARAGE TO BE DEMOLISHED COMPLETELY, AND NEW
GARAGE TO TAKE ITS PLACE.
G A4-e. (' -tv H, -V E LSD FT'A-��- t° t3 C- u sm � rz- s -;v Iz� c
BUILDING
CODES
CONSTRUCTION WILL COMPLY WITH:
BUILDING Q STRUCTURAL
2015 IRC
MECHANICAL
20151RC
PLUMBING
2615 UPC
ENERGY i VENTILATION
2015 WSEC
20'-0"
-------------------------------------------
r--- ------------------------------------
I
I
I"
I
I
• I 6" STEM WALL W/ 6" X 14"
I
CONT. FOOTING (TYP.)
I
.I
I
I
I,
2'-6" X 2'-6" X 8"
THICKENED FOOTING W/
ABU66 OR SIMILAR
(4) s4 BARS EA WAY
ITYP.
POST BASE (TYPJ?pof—
(2) PL
`I
I•.
:I
I CONCRETE SLAB
I
I
4" CONCRETE SLAB WI 6 X 6
n
I,
X 10/10 WWM, OVER 6 MIL POLY
'.
j I VAPOR BARRIER, OVER 4"
COMPACTED GRANULAR FILL
I
'I
I
I
F
e
BLOCK OUT FOR 3 +8
I
I.
WIDE DOOR W
I
I.
I,
I
m
I
'•
.M I
CONT. FOOTING I
BLOCK OUT FOR 12'
• I PLUMBING FIXTURES T49
WIDE GARAGE DOOR
AREA SEE FLOOR PLAN
Il FOR LOCATIONS.
I
• L-----J'I------------------
r.
I
------------J
6ST520 OR PER
DETAIL 'Q' SI
14'-4 1 /2"
12'-3" I
-4 1 /2
29,-0"
FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
FOUNDATION PER
DETAIL'A' S1
89T520 OR PER
DETAIL 'Q' SI
SILT FENCE DURING CONSTRUCTION ON DOWNSLOPE SIDE
NOTE TO BUILDER: KEEP EAVE
FROM EMENDING ACR059
PROPERTY LINE
51-3"
5. C,Irx
720 37th ST.
m
r
m
i
m
I
I I 20' REAR SETBACK LINE SILT FENCE ON DOWNSLOPE
/ SIDE OF SOIL STOCKPILE
� BMP GI23
TEMPORARY SOIL
1 I STOCKPILE LOCATION:
LL----- ---------------- --�- �\ I I COVER W/ VISOUEEN
—4-, LINE OF OLD GARAGE
TO BE DEOB LV+(tp2---to \ \ \ /
M
TSpp CV I Lez:-l-k5D q, T 6u7q-� - - - - �
I EAST. DECK SC .�`1i ` -r --(o -D D w /�/ S P D f c-T
D�S�s ��
-----_---
rsv
�lSTING S.S- LINc
m
ml
a
I
❑ 58T 1 1
I I
1 6' ALLEY BMP GI05 CITY OF ANACORTES • d design
S.S. — CON9TRUGTION ENTRANCE: WIDE X 20' PLANNING & BUILDING DEPT• J
- — — — — — — L�RTa'LFlIN7 COR$TRUGTION ACCESS W/ CRUSHED ROCK BASE P GONG. DRIVEWAY APPROVED PLANS (�, JIM DUNLAP
9.8. STUB -OUT LOCATION
PERMITIi: M L - 2n�� _ ���h (360) 982-0535
Il@
'-I i/4" (+/-) 0' MA ) ADDRESS: *;'// 37 JIMGJDDESIGNDRAFTING.COM
S.S. PL: 15.B0'
APPROVED BY:
SUBJECT TO FIELD INSPECTION. APPROVED PLANS I
/I SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. A
I PROPOSED VEL
HOSTING
I
WATER METER
I
FOUNDATION NOTES
• WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED
DIMENSIONS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD
• ENGINEERING SPECIFICATIONS, NOTES AND DRAWINGS
ACCOMPANIED WITH PLANS TO SUPERCEDE ALL INFORMATION ON
ARCHITECTURAL DRAWINGS. FOR ANY DISCREPANCIES BETWEEN
ENGINEERING AND ARCHITECTURAL DRAWINGS REFER TO
ENGINEERING.
• FOOTINGS ARE TO BEAR ON UNDISTURBED LEVEL SOIL DEVOID OF
ANY ORGANIC MATERIAL AND STEPPED AS REQUIRED TO MAINTAIN
18" DEPTH BELOW GRADE
• SOL BEARING ASSUMED TO BE 2000 PSI.
• FILL UNDER SLABS ON GRADE TO BE MIN. 4" DEPTH GRANULAR
MATERIAL COMPACTED TO 55%.
• CONCRETE SLABS TO HAVE CONTROL JONTS AT 25' MAX
INTERVALS EACH WAY.
• LURE MESH TO BE USED IN CONCRETE SLABS, POSITIONED IN
MIDDLE THIRD OF SLAB.
• U6E HIGH DENSITY POLYETHYLENE NIGH QUALITY VAPOR
RETARDER UNDER CONCRETE SLAB.
• A WATERPROOF MEMBRANE IS TO BE USED ON FOUNDATION WALLS
BELOW GRADE
• ALL BOTTOM PLATES AND ANY LUMBER IN CONTACT WITH
CONCRETE TO BE PRESSURE TREATED.
EAST.
DECK
(EAST. DECKS ARE LESS
THAN 18" ABOVE GRADE)
J �
20' FRONT SETBACK LINE
T
10-0" I
WATER FLOW i SLOPE
SLOPE APPROX. 2%
PL: 15.00, —
37th STREET
WATER LINE
12" CONC. STORM DRAIN
SITE PLAN
SCALE: 1/8" = 1'-0"
CRUSHED AGGREGATE GREATER
THAN 3" BUT SMALLER THAN 6"
It
CONSTRUCTION ENTRANCE SECTION
1/2" = 1'-0"
708 37th ST.
PROPERTY INFO.
SITE ADDRESS:
116 31TH STREET
ANACORTES, WA W221
PARCEL: P55610
ASSESSOR'S TAX ACCT.M: 3115-014-014-0010
QTR: NW, SEC: 30, TWN: 35, PING: 02
ZOIJNG DESIGNATIOI.4 R3
PARCEL SIZE: 1500 S.F.
PROPERTY OWNERS:
MICHELLE WOODLEE i DONOVAN SMALE
116 31TW STREET
ANACORTES, WA W221
PROJECT INFO.
GARAGE SIZE ONCL BATH) 984 S.F.
STORAGE LOFT SIZE: 644 S.F.
LOT COVERAGE
EXISTING
HOUSE FOOTPRINT INCL COV. DECK: 1314 S.F.
NEW
GARAGE FOOTPRINT 984 S.F.
TOTAL
EXISTING 1314 S.F. + 854 S.F. NEW: 2308 S.F.
OAT IS 1500 S.F.)
PERCENTAGE OF LOT: 30.895
IMPERVIOUS
SURFACE
EXISTING
TOTAL UNDER ROOF:
1314 S.F.
PAVED WALKWAYS:
60 S.F.
TOTAL EXISTING:
1314 S.F.
TOEW
TDER ROOF:
884 S.F.
GRAVEL DRIVEWAr.
330 S.F.
TOTAL NEW:
1324 S.F.
TOTAL
EM97ING 1314 S.F. + NEW 1324 S.F.:
2698 S.F.
EROSION CONTROL
NOTES
• CONTRACTOR TO INSTALL SILT FENCING ON DOWN
SLOPE SIDE OF ENTIRE EXTENTS OF EACH SITE UNDER
CO49TRUCTION. SILT FENCING TO REMAIN UNTIL ALL
CONSTRUCTION IS COMPLETED AND LANDSCAPE IS IN
PLACE.
• IN ADDITION TO SILT FENCING COVER ALL
STOCKPILED SOIL WITH VISQUEEN.
-D a f-rV*'6 Pi"I" 6
{ ° tX ( S-(-I ti G oak Z.F.
coo oj A (7i o tieD g PA _Z'E57 = O w U y
43'Alttrzoom. qew-Te�D R Y'
tA.) D I v I D V 07, tfv5391isYL_
SITE PLAN LEGEND
AREA OF NEW BULDING
0
NEW GRAVEL SURFACE
PROPERTY LINE
—
BUILDING SETBACK
LINE OF BLDG. FOOTPRINT
— — — — —
— LINE OF ROOF
UTILITY LINE
— —
SILT FENCE
X
14'-0"
14'-0"
W I
X
�— —
U
I — — —
LUJOIST5210 JOIST
HANGER (TYP.) s
-- N — — m
9j
_ M
I
A — — — +� 'I!I = a — _ — A A
LL
N
y
LOFT FLOOR FRAMING PLAN
SCALE: 1/4" = 1'-0"
�vD tVV t_,oN►71✓ZTVvt—S (N LoAr � W( 4TiUE
6u00-0 ADDS -to 12, F fteT-DP&'c> sAvvAx� l 1>
C)W, (n 1 V
L O 7 "f 0 73,, P>c( CA-'OD-e' ,
(� u k- 6L- - to c u s-ll�-D A� o pey,) S r D t oy- [ o F-7--.
28'-0"
14 -0"
14'-0"
L>~
=,y
III
•�
T
=S
I
p
d)
s
m
Ii
��
rO+�Q
GARAGE
=r
�
=S
I
UNE OF LOFT ABOVE
- -----
-------------
Q
b
1p
--
-------------�
s
I
2668 I
I
I
�
o ,- I
°
I
•� I I
D Um
I
�
A
I
00 ,m 5 I w+rm
I
12' W X S' H O.N. DOOR
.
14'-6" 12'-0" I'-b"
It
3-5 1 /2" 1 18 -11"
2S'-0"
FLOOR PLAN
SCALE: 1/4" = 1'-0"
1)k; ffegDaytrz Na%67 DrW 2 pu6-r
VENT u�lw Per TrtmlN•1"r£ w/ rltty 3
0 p j5v1 MG iv —iv 73 4 L GD l N g
EvJ
FLOOR PLAN NOTES
• WRITTEN DIMENSIONS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. VERIFY ALL DIMENSIONS AND
CONDITIONS IN THE FIELD.
• ENGINEERING SPECIFICATIONS, NOTES AND DRAWINGS
ACCOMPANIED WITH PLANS TO SUPERCEDE ALL
INFORMATION ON ARCHITECTURAL DRAWINGS. FOR
ANY DISCREPANCIES BETWEEN ENGINEERING AND
ARCHITECTURAL DRAWINGS REFER TO ENGINEERING.
• CONFIRM ALL DOOR, WINDOW AND ANY OTHER
ROUGH OPENNG.SIZES WRH OWNER/ CONTRACTOR
PRIOR TO WALL CONSTRUCTION
• ALL WOOD IN CONTACT WITH CONCRETE MUST BE
PRESSURE TREATED MATERIAL USE CORROSION
RESISTANT FASTENERS WHEN IN CONTACT WITH
PRESSURE TREATED LUMBER.
• EXTERIOR GARAr4E WALLS TO BE FRAMED WITH 2 X 6
STUDS AT 16" O.C. AND SHEATHED WITH We TI-II
NO -GROOVE SHEATHING/SIDING WITH I" 15ULDING
PAPER.
(Vjd design
JIM DUNLAP
(360) 982-0535
JI MOJDDESIGNDRAFTING.COM
W
Q
W
W
2
U
a
W
u-
O W
o
F v � Z
O
� H
N W z
Z p o
0
U =j Q
3 N 3 n
Z IL
0: w
U O0 Lu
W Q OU
7Lu O Of d co_I N Qd
m
O
O
mi
LL
06 Z
z 5
�a
a(3
z z
02
a O
U
N
W
.J W
IL L
DRAWN BY JAD
SCALE 1/4" = 1'-0" UNO
JD JOB# 1142NC17-SMAL
DATE 09/13/2017
REVISIONS
A2
SHEET 2 OF 6
TORCH DOWN ROOFING OR OTHER
MATERIAL SUITABLE TO LOW SLOPE
150 FELT
1/16" COX OR 095 SHEATHING —
I X 6 FASCIA
2X BLOCKING W/ (3)1-1/2' DIA.
SCREENED VENTS
PRE-ENG. CHORD TRUSSES 0 24" O.G.
3/4" T i G PLYWOOD OR 0815
SUBFL.00R
2 X10 JOISTS P I6"O.C.-
2 X 10 RIM JOIST
5l8" Ti-11 NO -GROOVE SHEATHING/
SIDING OVER 15* BULDING PAPER
W/i X 3 BATTS
2 X 6 STUDS 0 16" O.C.
ANCHOR BOLTS PER ENGINEERING —
SPECIFICATIONS (SEE DETAIL 'A' S0
PT 2 X 6 SILL PLATE
GRADE
WATERPROOFING MEMBRANE
CONTINUE OVER FOOTING
1'-6"
2 X 4 OUTLOOKER9
0 4'-0' O.G. (TYP.)
I
--�—
I I I
J —�--L—
I�
— L —�-
--
SLIGHT SLOPE TO TOP CHORD OF
_
_ _ _ -
_
TRUSS, APPROX 12' RUN X 2" RISE
_ _ _
_
^I LL
_
_ _ _ _
LL�
0
x
X
- - _
ip
a
X
I
_
_ _ _ -
_ _ _ _
al
_
i
-
- - - - U
- - - -
-
0'
-
'v
- - - - e
W
- SLIGHT SLOPE FOR -
-
DRANAGE: APPROX. —�
HURRICANE TIE 0 EA. TRUSS
_
_ - -
- 12' RUN X 2" RISE
- - _ -
_ _. - - - - - - - - - _ yU - ® -
- _ - - - -
LL
G
of
—
— —
X
<
-�--
I
- -T--T-
I I I
I- -T--
I
L 4 X 16 DF2 HPR
I
TYP.
OVERHANGS
ROOF FRAMING PLAN
SCALE: 1/4" = 1'-0"
HIGH PT. OF BULDING
6"STEM WALL -----------------------.
Imr 18" TALL CHORD TRUSSES
II �I (PLUS SLIGHT INCREASE IN
.�G_. SEE 'FOUNDATION REINFORCING' TABLE HEIGHT FOR SLOPE)
II SHEET 91 FOR REBAR SPECIFICATIONS
4" CONCRETE SLAB W/ WIRE x a FRAMING
MESH ON 6 MIL VAPOR BARRIER
a
I{' ° 2 X 16 JOISTS 0 I6" O.C.-
'
T
4" COMPACTED GRANULAR FILL
(2) #4 RE15AR CONT. IN FOOTINGS
TYP. WALL SECTION
SCALE: 3/4' = 1'-0"
GRADE (APPROX. 2% SLOPE)
LINE OF NATURAL GRADE -
CONCRETE SLAB
AVERAGE GRADE 0 BULDING - - _ - _ _ - -
SLIGHT SLOPE FOR DRANAGE;
APPROX 12' RUN X 2" RISE
LOFT AREA F STORAGE
BUILDING SECTION A - A
SCALE: 1/4' = 1'-0"
(aD)jd design
JIM DUNLAP
(360) 982-0535
JI MGJDDESIGNDRAFTING.COM
w,
ROOF NOTES
• TRUSSES TO BE SPACED AT 24" O.G. UNLESS NOTED
OTHERWISE
• ROOFING MATERIAL IS TORCH DOWN OR ANOTHER
MATERIAL SUTED TO THE LOW PITCH. -
• OVERHANGS ARE 12" WITH CONTINUOUS METAL
GUTTER ON DOWNSLOPE SIDE
• FASCIA SHALL BE 5/4 X 6 WITH CONTINUOUS METAL
GUTTER. BARGE RAFTERS SHALL BE 5/4 X 6.
• ALL BEAMS a HEADERS TO BE 4 X 8 D.F. M2 LINO.
• PROVIDE SOLID BLOCKING OVER SUPPORTS.
• TRUSSES/RAFTERS TO BE SHEATHED WITH 1/16" CDX
OR OSB SHEATHING WITH 15# FELT OR BETTER. USE
PLYWOOD SHEATHING ON ALL SOFFITED AREAS.
• PROVIDE ROOF CROSS VENTILATION FOR EACH
SEPARATE SPACE WHERE APPLICABLE.
TRUSS NOTES
• TRUSS MANUFACTURER SHALL PROVIDE DESIGN
DETAILS AND ENGINEERING FOR ALL TRUSSES. COPY
TO BE AVAILABLE ON SITE FOR FRAMING
INSPECTIONS.
• ALL TRUSSES SHALL CARRY THE MANUFACTURER'S
STAMP.
• ALL TRUSSES SHALL BE STORED, INSTALLED Q
BRACED PER MANUFACTURER'S SPECIFICATIONS.
• TRUSSES SHALL NOT BE ALTERED IN THE FIELD
WITHOUT THE APPROVAL OF THE BUILDING OFFICIAL
AND/OR APPROVED ENGINEERING CALCULATIONS
PROVIDED BY THE TRUSS MANUFACTURER
• ROOF TRUSSES TO BE SHEATHED WITH 1/16" CDX OR
OSB SHEATHING WITH 15N FELT OR BETTER. USE
PLYWOOD SHEATHING ON ALL SOFFITED AREAS.
• PROVIDE ROOF CROSS VENTILATION FOR EACH
SEPARATE SPACE WHERE APPLICABLE.
TOP OF CHORD TRUSS
DOWN SLOPE 84DE
TOP OF PLATE -
TOP OF SUBFLOOR
TOP OF PLATE
m
GRADE (4 TOP OF SLAB) r
SUGHT SLOPE FOR GRAIN
FLAT ROOF (VERY SLIGHT SLOPE)
HIGH PT. OF BUILDING
----------------------------------------------
I X 4 CORNER TRIM
.110 BOARD i GATT 5/8" -
NO GROOVE TI-II
SIDING/SHEATHING
I X 3 BATTS P 16" O.O.
(SUGGESTED)
NATURAL GRADE —
SOUTH ELEVATION
SCALE: 1/4" = I'-0"
12ow O.H. DOOR
T--OP -- S—
LAB ---------tr----— — — — — — — — — — — -----------------
11
—
SLAo TO BE SLIGHTLY L_J
15-18" TOTAL HEIGHT TO
AVERAGE GRADE HEIGHT IS
UNDER I6� RESTRICTION
AVERAGE GRADE
BELOW NATURAL GRADE
EAST ELEVATION
SCALE: 1/4" = I'-T
D i GATT 5/8"
tOOVE TI-II
,/SHEATHING
5ATTS F 16" O.0
ESTER)
1RAL GRADE
NATURAL GRADE
AVERAGE GRADE
I X 6 FASCIA
RE -GRADE
AVERAGE NATURAL
GRADE P BUILDING
— — —
— —
I
I
1
1
I
l
i
I
i
I
— —
— —
I
— —
— —
—
— —
— —
— —
— —
— —
L7
ri L� L-
L - J
WEST ELEVATION
SCALE: 1/4" = 1'-0"
HIGH PT. OF BULDING
TOP OF PLATE
.A
TOP OF UANDOWS i a
'URAL GRADE
TOP OF SLAB
Vjd design
JIM DUNLAP
(360) 982-0535
JIMGJDDESIGNDRAFTING.COM
NORTH ELEVATION
SCALE: 1/4" = I'-0"
GENERAL STRUCTURAL REQUIREMENTS - 2015 IRC
REFERENCE CODES & STANDARDS
• International Residential Code, IRC 2015
• Washington State Building Code
• National Design Specification for Wood Construction, NDS 2015
• Wood Frame Construction Manual, AWC 2015
• Building Code Requirements for Structural Concrete, ACI 318-11,
• Minimum Design Loads for Buildings And Other Structures, ASCE 7-10
• Steel Construction Manual, AISC 2015
DESIGN CRITERIA
DESIGN CRITERIA
J
DESIGN PARAMETER
VALUE
SOURCE
Q
Seismic Design Category
1D1'
IBC 1613
(YLLI
Risk Category
'll'
IBC Table 1604.5
Wind Exposure Category
B'
IBC 1609.4.3
Basic Wind Speed (3-second gust)
Design Wind Load
110 MPH
16.00 PSF
IBC Figure 1609.3(1)
ASCE 7-10 28.6-1
VERTICAL LOAD
LIVE LOAD
DEAD LOAD
J
Roofs
20 psf
15 psf
UFloors
40 psf
12 psf
Decks & Balconies
Ground Snow Load
60 psf
25 psf
10 psf
W
Exterior Wall
-
12 psf
Interior Wall
10 psf
Interior Partition
18 psf
Notes:
1. Vertical loads come from 2015 IRC Table R301.5, Minimum Uniformly Distributed
Live Loads
DEFLECTION LIMITS
STRUCTURAL MEMBER
LIVE
SNOW
LIVE+DEAD
Roof (plaster ceiling)
U360
U360
U240
Roof (non -plaster ceiling)
U240
U240
U180
Roof (not supporting ceiling)
U180
U180
U120
Floor Members
U360
-
U240
Horizontal Deflection (any case)
U200
U200
U200
Farm Buildings
-
-
U180
Greenhouses
-
-
U120
Notes:
1. The above minimum deflection limits are required by the 2015 IRC Table 1604.3.
These deflection limits are used unless noted otherwise.
2. Deflections limits are tightened in certain instances such as long spans (U480) and
sliding door headers (U600).
GENERAL REQUIREMENTS
Codes: All materials and work shall adhere to the minimum requirements of the Reference Codes
& Standards listed above. Contractor shall be responsible to comply with OSHA, Labor,
, and
Industry Standards. Contractor assumes full responsibility of construction methods used, safety
provisions employed, and the finished condition of the structure.
Construction Personnel: Only competent personnel familiar with construction and safety practices
relevant to the project should be employed to assemble and construct the work.
Construction Methods and Project Safety: The project drawings and specifications represent the
finished structure and do not indicate methods, procedures, or sequence of construction. The
builder must take necessary precautions to maintain and insure the integrity of the structure during
construction. Bradley Engineering, Inc. will not enforce safety measures or regulations, nor will the
owner or designer. Therefore, the contractor shall design, construct, and maintain all safety
devices and follow all pertinent regulations.
Temporary Support: The builder must provide adequate temporary support to all walls, roofs,
beams, columns, and floors during construction. Design of these supports are not included unless
specifically shown. Contractor shall be responsible for the adequacy of all temporary support
systems.
Specifications: All notes, call -outs, and details included within this design package are required
unless otherwise noted.
Verification: Verify all dimensions, elevations, and site conditions before starting work. Notify the
owner of any discrepancies.
Conflicts: Notes and details on the structural drawings take precedence over the general notes
and typical details. Written dimensions take precedence over scaled drawing dimensions. All notes
and details on the structural drawings take precedence over the architectural drawings.
Errors: The contractor is responsible to check the plans and site conditions and to notify the
architect/designer/structural engineer of any errors or omissions prior to the start of construction.
Changes: Written approval from the engineer of record is required for any structural changes to
the provided drawings. Changes may be made "in the field" with written consent of Bradley
Engineering.
Substitutions: Provide manufacturer's approved product evaluation reports and a list of all
proposed substitutions to the owner for approval before installation.
Similar work: Where construction details are not shown or noted for any part of the project, the
area shall be constructed in the same manner as similar work shown on the drawings.
Modification of structural members: Cuts, notches, and holes bored in trusses, structural
composite lumber, glue -laminated members, or I -joists are prohibited except where permitted by
the manufacturers recommendations.
Scope of Work: The scope of work of Bradley Engineering, Inc. is limited to the vertical and lateral
analysis of the subject structure. Bradley Engineering, Inc. takes no responsibility for items not
specifically addressed in the calculations, drawings, or call -outs.
Completion of Work: Submittal of these structural drawings to the client completes the present
scope of work and budget of Bradley Engineering, Inc. Other consultation, design, calculations,
mate time a vials b sis.
n
sketches, inspection, etc. after submittal of this report shall be billed on a and
Ownership of design package: The calculations, sketches, and other intellectual information
pertaining to the project shown herein are the sole property of Bradley Engineering, Inc. Bradley
Engineering, Inc. will furnish copies of this information to others only with the express consent of
the client.
FOUNDATION
• Allowable Soil Bearing Pressure = 1,500 psf
• Frost Zone Depth = 18 inches
Code: Cast -in -place concrete materials, placing, and testing shall conform to IBC chapter 19 and
ACI 318-11.
Geotechnical Report: Bradley Engineering strongly recommends that a geotechnical report be
performed by a qualified geotechnical engineer for all land based construction projects. If this
information is not supplied to Bradley Engineering, footings are designed for 1,500 psf allowable
soil bearing pressure.
Earthwork: Locate and protect underground or concealed conduit, plumbing, and other utilities
where new work is performed. Footings shall bear on undisturbed native soils and/or clean fill
compacted in lifts of one foot or less to 95% of a modified proctor per ASTM D1557. Soils shall be
firm and unyielding. All organic and deleterious material beneath the footings, foundations, and
slabs to be removed and replaced with 4" min. crushed rock compacted to 95% relative
compaction. For sub -grade below slabs, 92% relative compaction is acceptable.
Surface Drainage: Finished grades are to be at least 6" below wood siding. Lots shall be graded to
drain surface water away from foundation walls. The grade shall fall a minimum of 6 inches within
the first 10 feet. If 6 inches of fall is not possible, impervious surfaces shall be sloped a minimum
of 2 percent away from the building.
Footings: All footings shall conform to accompanying structural details. Specified footing
dimensions are minimums unless noted otherwise. Bottom of footings to be below frost zone (18")
Footing Drains: Footing drains shall be provided at the base of all footings and retaining walls
which will have earth placed against them. Washed drain rock must extend to within one foot of
finished grade. Footing drains shall be 4" perforated pipe routed down gradient to daylight, unless
otherwise specified.
Concrete: Mix and 28 day strength unless noted otherwise:
• Basement walls, interior slabs, and foundations not exposed to weather ............. 2,500 psi
• Garage slabs, porches, steps, and foundations exposed to weather .................... 3,000 psi
Reinforced Concrete: Place all reinforcing per plans, details, and applicable code requirements.
Lap all continuous bars 24 X diameter minimum. Reinforcing bars, bolts, anchors, etc shall be
securely tied in position prior to concrete placement. Reinforcing steel shall be free of rust and
coatings which may inhibit bonding.
Anchor Bolts: Provide z"x10" long wet -set or expansion anchor bolts @ 4' O.C. and within 6-12" of
corners with 3"x3"x4" square washers.
Adhesive Anchors: Epoxy anchors in concrete shall be Simpson SET-XP or Hilti HIT-HY 200-R or
equivalent.
Concrete Pier Pads: Pre -cast concrete pier pads are an easily installed and low cost alternative to
sono-tube foundations in certain low -load applications. Such pads may be substituted only if
specifically called out in structural drawings.
Waterproofing: Waterproof basement walls and crawl space foundations below grade.
CRAWL SPACE
Vapor Barrier: Cover entire crawl space with class I vapor retardant (eg 6 mil poly film). Extend 6"
up foundation walls.
Access: Access shall be provided to all under -floor spaces. Access openings through the floor
shall be a minimum of 18 inches by 24 inches. Openings through a perimeter wall shall be not less
than 16 inches by 24 inches.
Foundation Ventilation: Provide a minimum of 1 square foot of crawl space ventilation per 150
square feet of crawl space area. Space vents evenly to provide cross ventilation. Cover with 8"
corrosion resistant mesh screen.
SLAB ON GRADE
Slabs on Grade: See foundation plan for concrete slab thickness, reinforcement, and finish
requirements.
Garage Slabs: Unless noted otherwise, garage slab shall be 4" concrete slab with #3 rebar at 24"
O.C. each way or 6xil woven wire mesh, over 6 mil poly vapor barrier over 4" compacted
crushed rock. 12" thickened slab with (1) #4 continuous rebar required at garage opening.
Interior Slabs: Unless noted otherwise, interior slabs shall be 4" concrete slab with 6x6xi>o woven
wire mesh over 6 mil poly vapor barrier over 2" rigid insulation (where insulation is required) over
4" compacted crushed rock.
Reinforcing: Reinforcing bars or woven wire mesh shall be as noted on plans and shall be placed
1-1/2" above the bottom of the slab.
Drainage: Slabs that drain (garages, porches) shall be sloped a"-q' per 1'.
Flatness: Floor slabs shall be level to within 4' in any ten foot length. Flatness shall be checked
with a 10 foot straight edge within 24 hours of placement.
Concrete Topping: If specified on drawings, concrete topping may be installed over floor joists.
The concrete topping on a floor shall be installed per manufacturer's specifications. The topping
shall not exceed 1-1/2" in thickness and shall be less that 18 psf.
Glulam and Sawn Lumber Headers and Beams
8x diameter of the Sawn Lumber and
}--- largest hole (min) GLB hole zone
. v8�
Hole Size: The hole diameter should not exceed 2"
or 1/10 the beam depth. whichever is smaller.
Engineered Lumber Headers and Beams
LSL Hole Zone LVL and PSL 2x diarrieter of the
hole zone largest hole (min)
Hole Size:a size The maximum round hole for
engineered lumber is 2" for beam depths of 8-20".
General Notes
Allowed hole zone suitable for headers and beams with uniform loads only.
Round holes only
No holes in can5levers.
DO NOT cut notch, or drill holes in headers or beams except as indicated in illustrations.
WOOD FRAMING
Default Wood Types: Unless noted otherwise, the material for a structural member is as shown:
• Posts.......................................................... Douglas Fir #2 (D.F.2)
• Beams ........................................................ 4X10 Douglas Fir #2 unless noted otherwise
• Sawn Joists ................................................ Douglas Fir #2 (D.F.2)
• Studs, Sills, & Plates .................................. Hem/Fir (H.F.) or Douglas Fir (D.F.)
• Rim Joists (2x Joist) ................................... Same as floor joist material
• Blocking...................................................... Hem/Fir (H.F.) or floor joist material
• Exposed Structural Members ..................... Pressure Treated (P.T.) or Cedar
• Glued -Laminated (dry -use) ......................... 24F-V4 (GLB)
• Glued -Laminated (wet -use) ........................ Rosboro Treated 'X-Beam'
Moisture Content: The max moisture content shall be 19% at the time of installation of
connectors, nails, and bolts for framing members.
Pressure Treated Lumber: All members in contact with earth/concrete or exposed to the elements
shall be pressure treated (P.T.). Colorless end sealer shall be applied immediately to the ends of
members after fabrication and field trimming. Pressure treatment is not required for members
protected by a roof or overhang (12" minimum overhang required). Cedar may be used in lieu of
typical pressure treated lumber.
Rosboro Treated 'X-Beam' shall be used for all applications requiring P.T. glulam beams.
More info: http://www.rosboro.com
Blocking: Provide 2X or engineered lumber full depth solid blocking between joists and rafters at
beam and bearing wall locations. Trusses, structural composite lumber, glued -laminated
members, and I -joists shall be supported laterally as required by the manufacturers
recommendations.
Bearing: Use a minimum 2-1/2" bearing length for wood framing members unless noted
otherwise. Use enough studs to match or exceed beam width unless noted otherwise.
Glued Laminated Members: Glulam beams (GLB) shall conform to the following standards unless
noted otherwise:
• Lumber ............................................... Douglas Fir -Larch combination, 24F-V4
• Laminations ........................................ 2" Nominal
• Conditions of Use ............................... Dry -Use
• Adhesives ........................................... APA approved moisture -resistant
Engineered Lumber: Engineered lumber offers certain structural advantages over conventional
sawn lumber. All engineered lumber must be APA approved. Install per the aforementioned codes
and relevant manufacturers installation guides for each type:
• Wood I -Joists: Used extensively in floor and roof framing.
• Laminated Veneer Lumber (LVL): Built up on site to reduce heavy lifting
• Parallel Strand Lumber (PSL): Ideal for long spans and cantilevers
• Laminated Strand Lumber (LSL): Strong and straight engineered lumber
Walls Bearing on I -Joists: Unless otherwise noted, use double joists centered under wall or
partitions parallel to floor joists. If perpendicular to joists, provide solid blocking under wall.
Wood Structural Panels: APA rated sheathing is required for all wood structural panels. Unless
noted otherwise, the wood panel for each situation is:
• Roof Sheathing: 1 /2" CDX (recommended) or OSB with ply clips or T&G, 1 Old nails at il2"
O.C., no blocking required.
• Pr::scriptive Exterior Wall Sheathing: 7/16" OSB or 15/32" CD ply, 8d nails at 6"/12" O.C., no
blocking required.
• Exterior Shear Wall Sheathing: per shear wall plans.
• Interior Wall Sheathing: 1/2" Drywall, 1 Od nails at 6"/12" O.C., no blocking required.
• Floor Sheathing: 3/4" CD or OSB, 1 Old nails at 6"/12" O.C., glued & nailed.
• Panel Adhesive: Per APA Spec AFG-01
n
Walls: 3/8 hick min' r sheathing Is required for all exterior wall See
Shear VV t (minimum) APA rated s eat Ing q s
shear wall plans and shear wall table for sheathing grade, thickness, and nail spacing.
Stairs: The following elements are requirements for stair construction:
• Use (3) 2X12 D.F.2 for stringers
• Stairways have a required minimum width of 36"
• Stairways shall have at least one handrail 34"-38" above the nosing of stair treads. Handrails
may project 3-1/2" from the side of stairway
• Maintain a minimum it of headroom from stair nosing to nearest soffit
Advanced Framing: Advanced framing is encouraged by B.E. as a cost-effective and structurally
adequate alternative to conventional framing. Advanced Framing shall conform
to the
construction standards outlined in APA's Advanced Framing Construction Guide.
Studs: For headers from 0-6' long, (2) studs are required (1 trimmer and 1 king stud). For spans
over 6', use (3) studs (2 trimmers and 1 king stud). Include additional trimmers as specified.
DECKS & BALCONIES
Railings: Guardrail to be installed per IBC 2015 when height above grade exceeds 30". Guardrail
must be 42" high min. with max opening size so that a 4" sphere cannot pass through. Guardrails
shall be designed to withstand a 2001b point load applied in any direction and at any location on
the top rail and shall be designed to withstand a uniform load of 50 Ib/ft applied horizontally to the
top rail.
Attachment to House: Decks and balconies must be connected to the subject structure as shown
in pertinent structural details. A 1,500-lb deck tension tie is required at each end of the deck:
Typically, Simpson DTT2Z's are specified.
J
O
J
m
O
J
Q
Min. distance from Table A
0
Min, distance from Table A 1Y2' hole may be
cut inweb out -side
of hatched zone
6"' \
L 1_ 2 x D1 D1
Closely grouped round 12 2 x Ly
ID, /
6" 16"'
No field cut
-t minimum
holes are permitted if minimum
F^No field cut
Ill Do not cut
holes in
(applies to all holes
the group perimeter
holes in
holes larger
hatched
except knockouts)
meets requirements for
hatched
than 1'/a" in
zones
round or square holes.
zones
cantilever
Table A - Minimum Hole Distance
From Support
JOIST
TJI e
ROUND HOLE SIZE
SQUARE/RECTANGULAR HOLE SIZE
DEPTH
2'
3" 1
4"
1 5"
6Y,'
T
B'/e"
11"
2"
3"
1 4'
1 S"
6Y2'
T
834'
11"
210
l'-0'
1'6"
2'-0"
3'-0'
5.6"
1'-0"
2'-0"
2'6"
4'-0-
5-0"
9Y2"
230
1'6"
2'-0"
2'6"
T6'
F6"
1'-0'
2'-0"
T-0"
4'-6"
F-0"
360
1'-6•
2'-0"
3'-0"
4'-0"
6-0"
1'-6•
2'6"
T-6"
5'-0"
s6"
1
2 0
1'-0 "
V "
6
T-O"
2�_ .
0
3'-0'
3'6"
6'-0'
1,-0"
1,6"
2,6"
3 '-0"
5-0"
5,6"
6,6"
11 /s
230
1'-0
1' 6
2'-0 "
6
2' "
3'-0'
3'6"
6'6'
1'-0'
2'-0'
2'6"
3 '6"
5'6'
5'6'
7'-0"
360
1'6"
2'-0"
T-O"
T6"
4'6'
5'-0'
T-0'
1'6"
2'6"
3'6"
4'6"
6'6"
6'6"
T6"
1
210
1'-0"
1'-0'
1'-0 "
1'6"
2'-0'
2'6"
3'6'
6'-0 "
1'-0"
1'-0"
2'-0"
2'6"
4'-0"
4'6"
6'-6
B'6'
14"
230
1' 0.
1'-0'
1'-0"
1'6"
2'6'
2'6'
4'-0'1
T-0'
1'-0"
1'-0"
2'-0"
T-0"
4'-0'
1 5-0"
1 T-0
360
1'-0"
I 1'-0'
1 1'6'
2'6"
T6'
1 4'-0"
5'6'
B'-0'
1 1•-0"
1'6"
2'6"
4'-0"
6-0"
6'6'
1 B'-0
Leave Ya" of web (minimum) at top and bottom of hole. DO NOT cut or notch joist flanges.
For simple span (5' minimum) unrfonnly loaded joists used in residential applications, one maximum sue round
hole may be located at the center of the joist span provided that no other holes occur in the joist.
ROOFS
• Unless stick framing is specified on structural drawings, wood trusses are to be engineered by
a truss manufacturer (MFG'R).
• Trusses to be checked by truss MFG'R and contractor before installation.
• Truss MFG'R to be responsible for placement of girder trusses.
• Install triple studs (min.) directly below all girder trusses
• Contractor to install all lateral bracing in roof as specified by MFG'R.
• Perimeter and bearing wall headers to be 4x10 or 6x8 D.F.2 U.N.O.
• All overhangs to be as noted on plans (18" U.N.O.)
• Roof slope to be as noted on plans. Minimum slope i9 4' per 1' for drainage.
• Over -frame with 2x6 @ 16" O.C.
• Roof ventilation with ridge vent and vented soffit per IBC Table 12.03.2
• Attic access shall be provided for attics with an area greater than 30 sq. ft and height greater
than 30". The minimum opening size is 22"X30".
FRAMING CONNECTORS
Manufacturer: Simpson Strong -Tie construction connectors are specified, however, any nationally
recognized brand (Silver. KC, etc) may be used provided that they are equivalent in their ability to
carry all applied loads in all orientations.
Installation: All prefabricated items shall be installed in strict accordance with the manufacturer's
recommendations and requirements (locations, exposure, end and edge distances, fasteners, etc.).
Simpson Connectors: Unless noted otherwise, the following Simpson Strong -Tie construction
connectors shall be used:
• Post Caps: CBTZ, PCZ/EPCZ, BC/BCS
• Post Bases: CPTZ, PB/PBS, ABA/ABU/ABW
• Joist Hangers: LUC/LU/U/HU/HUC, HUTF/HUSTF (top -flange)
• Beam Hangers: HU/HUC/HUCQ/HGUS, LEG/MEG/EG (top -flange)
• Rafter Hangers: LSU/LSSU, LRUZ
• Truss and Rafter Connection: H1, H2.5A, or SDWC15600 at each heel to double plate
• Shearwall Holdowns: HDU/DTT with SSTB/PAB. STHD14 or STHD14RJ strap -type
hold-downs may be used in lieu of aforementioned holdowns.
• Floor -to -floor Strap -Ties: HDU2, MST48
• Deck Tension Ties: DTTZ
Fastener Requirements:The number and size of fasteners connecting wood members shall not be
less than that set forth in IBC Table 2304.9.1.
Staples: For roofs, floors and walls, the IRC permits 16 gage wire staples with a min 7/16" dia.
crown (per Table R602.3(1) footnote b).
FASTENING SCHEDULE (IBC TABLE 2304.10.1)
BUILDING ELEMENT
NUMBER AND TYPE OF FASTENER
LOCATION
1
Joist to sill or girder
3-8d common (2-1/2'W.113")
toe nail
2
Bridging to joist
3-8d common (2-1/2"xo.113")
toe nail at each end
3
1"x6" subfloor or less to each joist
2-8d common (2-1/2"x0.113")
face nail
4
Wider than 1"x6" subfloor to each joist
3-Bd common (2-1/2'W.113")
face nail
5
2" subfloor to joist or girder
2-16d common (3-1/2'xo.162")
blind and face nail
6
Sole plate to joist or blocking
16d (3-12"x0.162") at. W O.C.
face nail
... at braced wall panel
3-1 Sd (3-12"x0.162"),at 16" O.C.
wall panel
7
Top plate to stud
2-16d common (3-12"x0.162")
end nail
8
Stud to sole late
P
4i8d common (2-1/2'50.131")
toe nail
Stud to sole plate
2-16d common (3-12'x0.162")
end nail
9
Double studs
16d (3-12"0.162") at,24" O.C.
face nail
10
Double top plates
16d (3-12"xo.162") at 16" O.C.
typical face nail
Double top plates
8-16d common (3-1/2'x(0.162")
lap splice
11
Blocking between joists/rafters to top plate
3-8d common (2-1/2'x0.113")
toe nail
12
Rim joist to to late
1 P P
8d (2-12"x0.113") at 6" O.C.
toe nail
13
To plates, and intersection
P p es, laps s
2-16d common (3-1/2"x0.162")
face nail
14
Continuous header, two pieces
16d common (3-1/2'W.162") at 16" O.C.
along edge
15
Ceiling joists to plate
3-8d common (2-1/2'x0.113")
toe nail
16
Continuous header to stud
3-8d common (2-1/2'x0.113")
toe nail
17
Ceiling joists, laps over partitions
3-16d common (3-1/2'4.162")
face nail
18
Ceiling joists to parallel rafters
3-16d common (3-12"x0.162")
face nail
19
Rafter to plate
3-8d common (2-1/2'x0.113")
toe nail
20
1" diagonal brace to each stud and plate
2-8d common (2-1/2'x0.113")
face nail
21
1'x " to each beano
8 sheathing g
3-8d common (2-1/2'k0.113")
face nail
22
Wider than 1"x8" sheathing to each bearing
3-8d common (2-1/2'x0.113")
face nail
23
Built-up corner studs
16d common (3-1/2"x0.162") at 24" O.C.
24
Built-up girder and beams
20d common (*W.192") at 36" O.C.
face nail at top and
bottom, staggered on
opposite sides
2-20d common (4"x0.192")
face nail at end and at
each splice
25
2" planks
16d common (3-1 /2"x0.162")
at each bearing
26
Collar tie to rafter
3-10d common (3"0.148")
face nail
z7
Jack rafter to hip
3-10d common (3"xo..148'�
toe nail
face nail
2-16d common (3-12'W.162")
28
Roof rafter to 2X ridge beam
2.16d common (3-12'W, 162")
toe nail
2-16d common (3-1/2'W.162")
face nail
29
Joist to band joist
3-common (3-1/2"xo.162")
face nap
30
Ledger strip
3-16d16d
common (3-12x0.162")
face nail
31 Structural panels. siding. sheathing, etc
per sheer wall plans
_
ABBREVIATIONS
(E)
Existing
DBL
IDouble
MAX Maximum
SPEC.
Specification
(N)
New
FA.
Each
MFG Manufacturer
STD
Standard
(R)
Reuse/Remodel
ELEV.
Elevation
MIN Minimum
STR'L
SWctural
A.B.
Anchor Bolt
EXT.
I Exterior
N.A. Not Applicable
T.O.
1 Top Of
ARCH'L
Architectural
FND
Foundation
O.C. On Center
TJI Trus Joist, I Series
BLD'G
Building
FTG
Footing
Opp, Opposite
TpL 'Triple
BLICG
Blocking
GALV.
Galvanized
0S13 Onenteo Strand soam
TYP.
Typical
BM
Beam
GLB
Glulam Beam
PL Plate
UNF.
Unfinished
BTM
Bottom
Bo
GA.
Gauge
9
PLY. PI)tlfvood
U.N.O.
untie,Noted Otherwise
CL'G
Ceiling
G.B.
Gypsum Board
P.T Pressure Treated
V.B.
Vapor Barrier
CLR
Clear
G.E.
Gable End
REINF. ,Reinforced
VERT.
Vertical
CMU
Cont. Masonry unit
HORIZ.
Horizontal
REQ'D
Required
W/
With
CONC.
Concrete
INSUL.
Insulation
S.F Square Foot
W/O
Without
CONT. Continuous
INT.
1 Interior
SGL Single
WD
Wood
D F Douglas Fir
! SIM Similar
in
z
0
>>
W
0
(n
r
W Lu o
Q N
0 p
z
0
>
>�
of r
of �
w
r
m U
0 o rn
N W
v Y
Q 0Y J
0
U)
I-_
Z
W
LLI
a
+,
ti
o
W
rn
>,
ti
W
co
W
(�5
rnCr�
W
W
Q
N
q
� to
N
�
q
� O
N5 �
q
co
I
W
LIJ
V
Q
Q•^
V
J
5<
v!
W
N p
V)
S2
OF
4