Loading...
HomeMy WebLinkAboutPermit File 4317 Cherry Court (3) ;. vx� INSTALLED INSULATION CERTIFICATE P.O Box 2921 --2114.11141."- Office: (360)424-5179 Mt. Vernon WA Fax: (360)428-5081 I[IBIQLATION & SEIIVUUE5 lL We certify that the following residence has been insulated with the following materials: Flat Attic blow VALUE R-49 Slope Ceiling Batts VALUE R-38 Exterior Walls VALUE R-21 Crawl Space VALUE R-38 Address: 4317 Cherry Cr,Anacortes WA Certify by ; SP>.i' .o- L_®ZZGu't,D- Date Installed November 2021 Title Manager - _ - -= - - - - - "''' - ' e rii y Cod . * ' - -' : . - .-'_ , W ` Rim, rotssi Si n I ,.v� sIT .>:I°t~Nsto-N ENt.RLY E .Oe�t1A M ) . , o 1' 4, Residential Building Air Leakage Test (Blower Door Test) Results Permit #: Cherry Ct. lot# 4 House address or lot number: 4317 Cherry Ct, _ _-- -__,._-..w..._-.,___..___ ____._____ City: Anacortes Zip: _98221 Cond. Floor Area (ft2): 3,108 _ Age of house: Brand New _ Source (circle one): ifi Plans ) Estimated Measured Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: ACH!}c, = (CFM50 x 60)! Volume Where: CFM50 = Blower door fan flow at 50 Pascal pressure difference Volume = Conditioned Floor Area of the housing unit x ceiling height Blower Door Test Result: 4.0 ACH50 1 ,900 CFM ar�50Pa 3 L - - --______ __- _-- - -._ _ _ Ring (circle one if applicable): Open A i C • Blower Door Fan Location: blew .i %' .''r`1'' t.- Weather Conditions: _ ' ! 0L,6 .� 1 certify that these blower door results are accurate and determined using standard industry protocol. Company Name: Master Insulation & Services LLC Technician: Florentina Galvez Technician Signature: ./\ .oi,s Date: `2•vZ 2,.__ Phone Number: 360-424-5179 .2015 Washington State Energy Code reference: 1 402.4. 1,2. Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not i exceeding 5 air changes per hour. 'testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shalt be si ned b 1 the arty condnetin the test and rovided to the code o 'idol. *resting shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed sealing (see Table R402.4.1 . 1 ), operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test.