Loading...
HomeMy WebLinkAboutPermit File BLD-2022-0073 3815 Copper Pond ,. � City of Anacortes Invoice/Permit #: BLD-2022-0073 ` 3 904 6th Street } ° Applied date: 02/08/2022 P.O.Box 547 Issue date: 02/08/2022 w 4+ ''` `> Anacortes, WA 98221-0547 Expire date: 08/07/2023 (360) 293-1901 -7.,,s . - Job Address: 3815 COPPER POND Permit Type: PV Solar Permit ANACORTES WA 98221-1154 Project: APN: P108211 Remarks: Install solar PV system. Owner: 360-941-2689 Owner: ASKEY JOEL S Contractor: WESTERN SOLAR INC. Address: 3815 COPPER POND Address: 4041 HOME RD ANACORTES WA 98221-1154 BELLINGHAM WA 98226-9158 Phone: Phone: (360) 746-0859 License #: General Information: Fees: Building Valuation 1346 Building Permit Fee 50.95 Plan Review Fee 33.12 State Building Code Fee Resi 6.50 Total Calculated: 90.57 Deposits/Receipts: 0.00 Total Due: 90.57 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read anti-e'g ined this application and know the same to be true and correct. . SIGNATURE OF OWNER OR AUTHORIZED AGENT ISS EBYr Notes: Exterior/Interior DC Conduit Runs to be labeled as: "Photovoltaic Conductors" Main Disconnect to be Identified as: "Photovoltaic Power Source" Prime Consultants Inc. •1- dba. Western Solar Inc. Design meets requirements of: d 4041 Home Rd Ste A WAC 51-54A-0605 Bellingham, WA 98226 Section 605.11.1.1, 605.11.1.2 . • LIC#: WESTES*910]0 09 Total PV Array Area: 433.09 sqft Total Roof Area: N 2,500 sqft - Project Manager: 0/0 Roof Area of Array: 170/0 Eric Blatz 33% Rule Applies 4041 Home Rd Ste A PV System installed with 18" setback 1 Bellingham, WA 98226 from ridges P • •• Tel: 360-224-9839 Installing Electrician: ,off CODE co Prime Consultants Inc. e 18" ridge & dba. Western Solar Inc. �� \- y 36" rake edge setbacks 4041 Home Rd Ste A Bellingham, WA 98226 M 1 1 * LIC#: WESTES*872DD al + 1891 'C2,> a JClient Name: ��� : * < � 1:1:13 4. 3815 Coeyer Pond pp T��'IEL�1N�� Anacortes, WA 98221 Parcel # P108211 I MM L = MM Project Size: • Existing Roof SFR: N 2,500 sf MM 8.51 kW PV System Proposed PV Solar Array: 433.09 sf ������ Sales/Designer: Callum McSherry N Issue Date: W E 2/3/2022 11 S `- +- Site Plan 18" ridge & 36" rake edge setbacks PSE Meter & PV System Disconnect Notes: (23) Panasonic EVPK370K Evervolt Series Black 96ce11, 370 Watt Photovoltaic Modules Exterior/Interior DC Conduit Runs to be labeled as: Total System Size: 8,510 Watts DC, 8.51 kWs "Photovoltaic Conductors" Vmp=37.4 V, Imp=9.90 A, Voc=44.1 V, Isc=10.55 A Main Disconnect to be Identified as: Module Dimensions: 40.0" x 67.8" x 1.2" "Photovoltaic Power Source" Prime Consultants Inc. Installed per Manufacturer Recommendations dba. Western Solar Inc. Design meets requirements of: on roof of residence using flushmount Snap N Rack 4041 Home Rd Ste A WAC 51-54A-0605 Bellingham, WA 98226 Mounting System installed at 48" on center, LIC#: WESTES*910J0 Section 605.11.1.1, 605.11.1.2 into premanufactured trusses at 24" o.c. Meets all City of Anacortes Structural Permitting Requirements Project Manager: 43 lbs per solar module x 23 modules = 989 lbs Eric Blatz 18.83 sqft per solar module x 23 modules = 433.09 sqft 4041 Home Rd Ste A Panasonic Evervolt 989 lbs / 433.09 sqft = 2.28 lbs/sqft Bellingham, WA 98226 Tel: 360-224-9839 370W BoB Modules 30° comp Installing Electrician: 11I 36" rake edge setback Prime Consultants Inc. 18" ridge setback , ;1, dba. Western Solar inc. +11 ,1 l i 4041 Home Rd Ste A i 1 1 i� ; Its' Bellingham, WA 98226 I f; 1�Ii LIC#: WESTES*872DD �� �; II I III I 1 I�I lhI ,a ;11 , 1 is I i!' ha 18" ridge & 111 ; It 1i 1l , I , , g ill illi li'I I c ' 1j Client Name: 36 rake edge 11 ;1,1 1,11 l �,l!H ��!, Joel Askey setbacks i ,1: re% 3815 Copper Pond liii1 /11 1i+1 Ii jt � �; Anacortes, WA98221 II 111,I11 111 1+i! a� 'I1/1 + jl 'l; 1/111 ii � �;'II o Project Size: ' ; I,1 1 111 J 1 1, ;Ili 1 i i ' 8.51 kW PV System 40° comp + i1,1�il !i� Ili i Ian 1. ^, _ i i, !, i t III, ' +1 I R coop A , i 1�I 1 1 1 11 ` l i`t r Sales/Designer: t o CO _.__— 11 i i -"A�Ap 11 I; �O ,v i' Callum McSherry .1.7 CAphk, Ty. l Issue Date: �' °i 2/3/2022 20. �,(� f891 ,N� N ��,� 4 e n* � `° r Roof Overview 4 0 FleLv►�� L w E /. ►l 24' $ To Be Completed By the Applicant Project Address: 3815 Copper Pond, Anacortes, WA 98221 Project Applicant:Western Solar/ Cheryl Beadle Applicant Email:info@westernsolarinc.com Phone No.:360-746-0859 Site Owner Name:Joel Askey PV system Description: Install Solar PV System 8.51 kW Modules: Panasonic 370 BoB (23), Inverters: Enphase Energy IQ-7+ (23) Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or j ❑ townhome. 2. PV System is designed for rooftop of house in general compliance with applicable ❑ codes. 3. Mounting system is engineered and designed for PV. ❑ 4. Rooftop is made from light weight material such as shingles. ❑ 5. PV system will be permitted and pre-approved by Labor&Industries Electrical ❑ division. 6. To address uplift,panel are mounted no higher than 18"above the surface of the 4 ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings,race ways,and all other ❑ appurtenances weight no more than one of the following. IF Yes, indicate which: `AN°more than three and one half(3.5 pounds per square foot(PSF) ❑Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF ❑Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. 16 ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to D ❑ pitched roofs). Comments: .1 By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑ Yes ❑ No %."04 City of Anacortes Photovoltaic System Permit M44' Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic(PV)systems, including roof top arrays,ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor& Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code(Current Edition) International Fire Code (Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV(OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot,with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE:The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review. 1 PLANNING. COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT • RESIDENTIAL BUILDING PERMIT APPLICATION MarlingAddress: P.O. Box 547, Anacortes, WA 98221 �� Office Location: 904 611'Street, Anacortes WA 98821 �- Phone: (360) 293-1901, Fax: (360) 293-1938 PLEASE REFER TO THE RESIDENTIAL BUILDING PERMIT CHECKLIST BELOW FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS(Street,Suite#): Parcel(s)#: P 108211 3815 Copper Pond,Anacortes,WA 98221 Subdivision/Lot#: Project Valuation: $ 1 ,346.21 APPLICANT:Cheryl BeadleNVestern Solar Inc. Phone:360-746-0859 Fax: Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A,Bellingham,WA 98226 cheryl@westernsolarinc.com PROPERTY OWNER:Joel Askey Phone:360-941-2689 Fax: Address(Street,City,State,Zip): E-Mail Address:. 3815 Copper Pond,Anacortes,WA 98221 Jsaskey@gmail.com CONTACT PERSON:Cheryl Beadle Phone:360-746-0859 Fax: Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A,Bellingham,WA 98226 cheryl@westernsolarinc.com LENDING AGENCY: Phone: Fax: Address(Street,City,State,Zip): E-Mail Address: CONTRACTOR:*Western Solar Inc. Phone:360-746-0859 Fax: Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A,Bellingham,WA 98226 cheryl@westernsolarinc.com *All Professional License#: Exp.Date:04/25/2022 Contractors&Subcontractors must have a valid City of Anacortes CCWESTES*910J0 business license prior to doing work in the City. Contact the City's Business License#: Exp.Date: Finance Department at(360)299-1968. 602258981 12/31/2022 PROPOSED WORK: Install Solar PV System PROPOSED NEW SQUARE FOOTAGE: Basement SQ': Finished Basement: ❑ Unfinished Basement ❑ I"Floor SQ': Garage/Carport SQ': 2'Floor SQ': Deck/Covered Porch/Patio SQ': Fire Sprinkler: Yes ❑ No ❑ Lot Area SQ': Is construction associated with an accessory dwelling unit? Yes ❑ No ❑ I declare under penalty of perjury that the information I have provided on this form/application is true, correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: Cheryl Beadle Owner ❑ Agent G (specify): Western Solar Inc. Signature: Date: 2-3- •2.2_ Page 1 of 3