HomeMy WebLinkAboutBLD-2017-0545 - RE-ROOF COMMERCIAL City of Anacortes Invoice/Permit#: BLD-2017-0545 904 6th Street Applied date: 1 0/1 71201 7 P.O.Box 547 i Issue date: 10/1712017 " t/1s Anacortes, WA 98221-0547 Expire date: 04/15/2019 `1 Job Address: 904 4TH ST Permit Type: Reroof Commercial Permit ANACORTES WA 98221 Project: APN: Remarks: Remove existing metal roofing, add roof sheathing and install 28 squares of 60 mil TPO roofing at the Wood Mill building. Owner: DAKOTA CREEK INDUSTRIES INC Contractor: HYTECH ROOFING, INC Address: PO BOX 218 Address: 7381 GUIDE MERIDIAN RD ANACORTES WA98221-0218 LYNDEN WA98264-9214 Phone: Phone: (360)354-4335 License M HYTECRI*106P5 General information: Fees: Building Valuation 19785 Building Permit Fee 321.25 State Building Code Fee 4.50 Total Calculated: 325.75 Deposits/Receipts: 0.00 Total Due: 325.75 n —I vm 2 p 91 I- % m4 010 r� u Awa rro a Ln < m ' A I l' - o- a cnn t 2 C • N I� � S Q rt a O •. a 'n z Ci cr THIS PERMI BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DO'S, OR IF CONSTRU I N O ORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANYTIME AFTER WORK IS COM IVED. I HEREBY R FY AT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PRO VSIONS OF LAW AN OR ANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN 0F�'NOT, THE GRANTI O AP MIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHEZ116TATE OR LOCAL W GU TING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. -a � m N Ln a tll tqr . t -J J SIGNATURE OF OWNER OR AUTHORIZED AGENT IS Y HYTECH ROOFING iNc. 7381 Guide Meridian Rd. Lynden, WA 98264 Office (360)354-4335 Fax (360)354-1335 e-mail dgross@hytechroofing.com 10/13/17 PROJECT SCOPE Dakota Creek Industries,Inc. 904 4'h Street,AnacOrteS, WA 98221 Project Mar:Dan Gross 360-354-4335 OFFICE,360-815-5467 MOBILE BID SCOPE: (100%Reroof of Wood Mill Roof) • Remove existing metal roofing and haul away. • Install '/4"underlayment over existing wood deck. • Install gray, 60 mil thick, Carlisle Sure-Weld thermoplastic polyolefin membrane roofing system. • Provide standard Carlisle Sure-Weld twenty year non-prorated warranty with defective labor and material coverage. • Provide standard Hytech Roofing two year workmanship warranty. • Obtain and provide City of Anacortes re-roofing permit. PRICE: $19,785.00 OCT 1 3 2011 EXCLUSIONS: CITY OF ANACOHTES • Sales tax. NOTE: Existing roofing is a single layer of metal roofing over plywood sheathing on a 5/8"CDX plywood substrate. CITY OF ANACORTES PLANNING & BUILDING DEPT: ,APPROVED PLANS PERMIT t!: ,t — 21/ 7 ADDRESS: _9c '212�' S eC �— APPROVED BY; /L-�/ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. r � ; ,� . • . a iv ';, N t69 tgfill s r Aa w g � 1� # it'p � o E� x� W� ' d �"r �.•1 w�lre IMP '• '��'�� w awcxwg,� IAIIrTA �._, Y �• � .''?4 fax ," 1 • Z, �`—''� i • — "'w - a+•rn�'_ra'�`d: 7�. f wA'it"i•a,t•n !ttu'�.Iv -rtrc � ..—_ •r! o Eommereial Ave fta. erg v • ' F `so .- nou { r 1 b-4 ar F i 7 fr-, O O O g � N E O N U L 3 N iJ N f p p � ` G y6 a OJ n N '1-1- UA' E 00 00 to tF � Cl) co O] Ice �A 8� � ��." _�, �,� "•� �� C@1L '�_ 1.17�3� myr� �� ,",_,� � W C L U O N s U p t U y c a £ igyu r N 4. O EXPERIENCE THE CARLISLE DIFFERENCE SYNTEC SYSTENfE Sure-Weld' TPO Reinforced Membrane -"' Carlisle's tan and white TPO membranes are ENERGY STAR®*-qualified and. California Title 24 compliant and can contribute toward LEED®(Leadership in Energy and Environmental Design)credits. Optional APEEL"Protective Film F ,+ Carlisle's Sure-Weld TPO reinforced membrane is available with an optional APEEL Protective Film,saving time and labor by eliminating the need .� for roof cleaning upon project completion.Carlisle's innovative APEEL Protective Film can be left In place for up to 90 days without affecting the integrity of the film,guarding the TPO membrane's surface from scuffs and dirt accumulation during installation.Durable and easy to remove,APEEL Protective Film improves aesthetics and long-term reflectivity and is ideal for re-roofing,re-cover,and new construction projects. 7" OCTRGURRO XT `� Overview 0 WEATHERING PACKAGE PaePECTNE FILM Carlisle's Sure-Weld TPO reinforced membrane Is a premium,heat- weldable,single-ply thermoplastic pblyolefln(TPO)sheet designed for new Features and Benefits roof construction and re-roofing applications.Sure-Weld High Slope(HS) » Outstanding puncture resistance membrane is formulated with additional flame retardant for higher-slope „ Chlorine-free with no halogenated flame retardants fire code approvals.Sure-Weld EXTRA is 80 mils thick for significantly higher strength and weatherability. » Plasticizer-free;does not contain liquid or polymeric plasticizers Sure-Weld TPO membranes use advanced polymerization technology Excellent resistance to impact and low temperatures thatcombines the flexibility of ethylene-propylene(EP)rubber with the » Excellent chemical resistance to acids,bases and restaurant exhaust heat weldability of polypropylene.All Sure-Weld TPO membranes include emissions OctaGuard XT",an industry-leading,state-of-the-art weathering package. OIL 2218 Class 4 hail rating OctaGuard XT technology enables Sure-Weld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe Exceptional resistance to heat,solar UV,ozone and.oxidation climates, » Manufactured using a hot-melt extrusion process for complete scrim encapsulation Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and bottom plies. 11 100%recyclable(see Carlisle's Recyclability Statement) The combination of the fabric and TPO plies provides high breaking and x Enhanced with the OctaGuard XT weathering package tearing strength,as well as excellent puncture resistance.The relatively x APEEL Protective Film application guards the TPO membrane's smooth surface of the membrane produces a total surface fusion weld surface from scuffs and dirt accumulation during installation, that results in a consistent,watertight,monolithic roof assembly.The improving the roof system's appearance and long-term performance membrane is environmentally friendly and safe to install. APEEL Protective Film can be left in place for up to 90 days without Carlisle's standard and HS TPO membranes are available in highly reflective degrading due to its excellent heat-and UV-resistance white,tan,an ra in bath 45-mil and 60-mil hicknesses.80-mil Sure- Weld EXTRA(including HS)is also offered in white,gray,and tan colors. Sixteen special colors are also available(see Carlisle's TPO Color Palette brochure). Carlisle's TPO is.offered In 4-,and 6-ft perimeter sheets and 8-,10-,and 12-ft Sure-Weld sheets.Sure-Weld HS and special color TPO membranes are available in limited sizes. ONEROUS 800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com DIFFERENCEEXPERIENCE THE CARLISLE Sure-Weld TPO Reinforced Membrane Installation 1, Sure-Weld TPO roofing systems are quick to install,as minimal labor K The Carlisle Mechanically Fastened Roof System' Retion and few components are required.TPO systems are installed using an starts by fastening 1e Insu a Ian with a minimum of 4 fasteners per Automatic Heat Welder,making sheet welding fast,clean,consistent, 4'by 8'board.The membrane is mechanically fastened to the deck and easy to learn,while reducing strain on the roofing technician, using HP-X-Fasteners and Piranha Plates"or HP-XTRA Fasteners 2. APEEL Protective Film should be removed from within areas that and Piranha XTRA Plates.Adjoining sheets of membrane are are to be heat-welded together.In areas that do not require heat- overlapped over the fasteners and plates and joined together with a welding,the APEEL Protective Film can be left in place for up to minimum 1%2°-wide(4 cm)hot-air weld. 90 days.When the installation of the entire TPO roofing system is complete,.remove and discard the APEEL Protective Film. PropertiesTypical Physical Property _ ASTM D6878 Requirement 45-mil 0-mi 80-mil EXTRA Tolerance on Nominal Thickness,%ASTM D751 test method +15,-10 ±10 ±10 ±10 Thickness Over Scrim,in.(mm) ' 0.015 min 0.018 typical 0.024 typical 0.034 typical ASTM D7635 optical method,average of 3 areas (0.380) (0.457) (0.610) (0.864) Breaking Strength,Ibf gdN). 220(976 N) 225(1,0)min 250(1.1)min 350(1.6)min ASTM D751 grab min 320(1.4)typical 360(1.6)typical 425(1.9)typical Elongation Break of Reinforcement,% 75 min 15 min 15 min 15 min ASTM D751 grab method 25 typiral 25 typical 25 typical searing Strength,Ibf(N) 55(245)min 55(245)min 55(245)min 55(245)min ASTM D751 pope.B 8 in.x 8 in. 130(578)typical 130(578)typical 130(578)typical Brittleness Point,°F(°C) -40(-40)max -40(-40)max -40(-40)max -40(-40)max ASTM D2137- ---- - -50(-46)typical -50(-46)typical -50(-46)typical Linear Dimensional Change,% ±1 max ±-1 max ±1 max ±1 max ASTM Or 204.6 hours at 158`F 0.2typical -0.2typical -0.2 typical Ozone Resistance,no cracks 7X ASTM D1149,100 pphm,168 his PASS PASS PASS PASS Water Absomflon Resistance,mass% ;3 ±3.0 max ±3.0 max ±3:0 max ±3.0 max ASTM D471 top surface only 166 hours at 158°F water j 0.90 typical 0.90 typical 0.90 typical Factory Seam Strength.Ibflln(kN/m)ASTM D751 grab method 66(290)min 66(290)min 66(290)min 66(290)min .................._.--..-.......-._.-_-_ -_-_--_....._.-.-...-.-_-__-___...-_. -._-.--:-:_.-....-.-.--__..--"_ Field Seam Strength,Ibf/in(kN/m) No requirement 25(4.4)min 25(4.4)min 40(7.0)min ASTM Of 876 tested in peel 50(8.8)typical 60(10.5)typical 70(12.3)typical ....__,_ .-.-._...__ �_ .__...__._.- _.-__-_ - . .--_.-. .-.__.___ .. .......... ...._-_-_- Water Vapor Permeance,.Perms No requirement 0.10 max 0.10 max 0.10 max ASTM E96proc.B 0.05 typical 0.05 typical 0.05 typical - Puncture Resistance,Ibf d" No requirement 250(1.1)min 300(1.3)min 400(1.8)min �. FTM 101 C,method 2031(see supplemental section) 325(1.4)typical 350(1.6)typical 450(2.0)typical Properties After Heat Aging ASTM D573,5376 hours 0 240°F Breaking strength 198(881)90%min 205(912)min 225(1000)min 315(1400)min Elongation Relief. 13.5(90%)min 13.5 min 13.5 min 13.5 min Tearing Strength 33(60%)min 33 min 33 min 33 min Weight Change,% ±1.0 max 1.0 max 1.0 max 1.0 max Typical Weights Ib/ttx(kg/nl _ 0.23(1.1) 0.29(l.4) 0.40(2.0) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and Information is intended as a guide and does not reflectfhe specification range for any particular property of this product. i SYNTEQ SYSTEMS Sure-Weld TPO Reinforced Membrane 4. The Carlisle Fully Adhered Roofing System installation begins by EXTREME Testing for Severe Climates fastening the insulation at the required density necessary to meet ASTM Standard D6878 is the material specification for Thermoplastic the appropriate warranty or wind load requirement.The substrate Polyolefin-Based Sheet Roofing.It covers material property requirements and membrane are then coated with an appropriate Sure-Weld TPO for TPO roof sheeting and includes initial and aged properties after heat bonding adhesive and the membrane is ralled into place. and xenon-arc exposure.As stated in the scope of the standard,"the tests Review Carlisle specifications and details for complete installation and property limits used to characterize the sheet are values Intended to Information. ensure minimum qualityfor the Intended purpose."Carlisle's goal is to produce TPO that delivers maximum performance for the intended purpose Precautions of roofing membranes.Maximum performance requires the membrane to Sunglasses that filter out ultraviolet light are strongly recommended,as far exceed the requirements of ASTM D6878, tan and white surfaces are highly reflective.Roofing technicians should dress appropriately and wear sunscreen. Heat Aging accelerates the oxidation rate that roughly doubles for each » Surfaces may become slippery due to frost and ice buildup.Exercise 18°F(10°C)increase in roof membrane temperature.Oxidation(reaction with oxygen)Is one of the primary chemical degradation mechanisms of caution during cold conditions to prevent falls. roofing materials. » Care must be exercised when working close to a roof edge when the surrounding area is snow-covered,as the roof edge may not be Carlisle Testing—Heat Aging Clearly Visible. ASTM Requirement Sure-Weld Requirement Use proper stacking procedures to ensure 5ufficlent stability Of the rolls. ASTM TEST i 32 weeks"' 52 weeks Exercise caution when walking on wet membrane.Membranes may be 240°F slippery when Wet. `"Comparable to 1,024 weeks(20 years)at1857 for 6 hours/day. Store membrane in the original undisturbed plastic wrap in a cool, » Test specimen is a 1"by 4"piece of 45-mil membrane unbacked, shaded area and cover with light-colored,breathable,waterproof placed in circulating hot-air oven. tarpaulins.Membrane that has been exposed to the weather must he Criterion—no visible cracks after bending aged test specimen around prepared with Weathered Membrane Cleaner prior to hot-air welding. 0.25"-diameter mandrel. » Take care not to stand or place heavy objects on the edge of folded- over membrane,as this could cause a hard crease in the membrane. Xenon-arc exposes the membrane samples e,the heat combined effect of UV, visible and infrared radiation as well as ozone,heat and water spray to » Maximum sustained temperature not to exceed.160°F(71°C)for TPO greatly accelerate the effects of outdoor weathering.The radiation dose is membrane. measured in kilojoules per square meter(kJ/m2)at 340 nm machine UV Do not use razor blades or other sharp tools to cut the APEEL Protective wavelength.The irradiance power of the xenon-arc lamp Is measured in Film while it is still adhered to the TPO membrane as damage to the watts per square meter(W/ml). underlying membrane may occurs.Pull the protective film away from the membrane prior to cutting. Carlisle _ » Remove APEEL Protective Film by pulling towards the center of the Sure-Weld Results roof.Do not remove the film by pulling towards the roof edge. ASTM TEST ASTM 13687B 45-mil 60-mil eo-mil Requirement » A static electric charge may develop when removing APEEL Protective kJ/m=at non 10,080 17,640. zo,16o z7,7zo Film from the surface of the membrane sheet.To avoid the possibility — -----------...------------ ------------ of Ignition,lids must be closed on any flammable products and a fire » Test specimen is a 2.75"by 5.5"piece of membrane,unbacked, extinguisher should be readily available. weathering side facing arc lamp. Color membranes will'fade'over time mainly due to the ultraviolet Criterion—no visible cracks when viewed under 10x magnification portion of sunlight,Since most roof surfaces are exposed to variable " while wrapped around 3"-diameter mandrel. sunlight,some areas will be more susceptible to color changes caused by UV fading.Warranties for color membranes do not cover fading of colors. 800-479-6832 1 P.O.Box 7000 1 Carlisle, PA 17013 1 Fax:717-245-7053 1 www.carlislesyntoo.com EXPERIENCE THE CARLISLE DIFFERENCE / SYrilTEC 3YSTEP✓YH Sure-Weld TPO Reinforced Membrane Environmental Cycling subjects the membrane to repeated cycles of heat Radiative . . - - , aging,hot-water immersion,and xenon-arc exposure. , LEED » ASTM requirement-none White Tan Gray • Carlisle EXTREME test*: Test Method TPO TPO TPO - 10 days heat aging at 240°F(116°C)followed by ENERGY STAR-Initial solar Solar Spectrum 0.79 0.71 N/A reflectance Reflectometer 5 days water immersion at 158°F(70°C)followed by ENERGY STAR-Initial solar J Solar Spectrum 0.70 0.64 N/A - 5,040 kJ/ma(2000 hours at0.70 W/m2 irradiance)xenon-arc reflectance after 3 years Retlecmmeter exposure (uncleaned) *Test specimen is 2.75"by 5.5"piece of membrane with edges sealed. CRRC-Initial solar ASTM 01549 0.79 0.71 0.46 reflectance *Criterion-after 3 complete cycles,test specimens shall remain GflflC-Solar reflectance ASTM C1549 0.70 0.64 0.43 flexible and not have any cracking under 10x magnification while after 3 years (uncleaned) wrapped around a 3"-diameter mandrel. CRRC-Inhial thermal ASTM C7371 0.90 0.86 0.89 Supplemental Approvals, Statements eminance and Characteristics: CRRC-Thermal eminance ASTM 01371 0.86 0.87 0.88 after 3 years (uncleaned) - _-_-y...---.-.-.---.-.-.-.-_-----.-......................--------' 1. Sure-Weld TPO meets or exceeds the requirements of ASTM D6878 LEED-Thermal emittance I PASS 0.90 0.86 0.85 Standard Specification for Thermoplastic Polyolefin-Based Sheet SRI -Initial 3 09 Bs 53 Roofing. (Solar Reflectance Index) 2. Radiative Properties for ENERGY STAR,Cool Roof Rating Council SRI -3 year aged1 85 77 48 (CRRC)and LEED. (Solar Reflectance Index) i 3. Sure-Weld TPO membranes conform to requirements of the US Solar Reflectance index(SRI)is calculated per ASTM E1980.The SRI is a measure of the E.P.A.Toxic Leachate Test 40 CFR art 136 performed b an roof's ability to reject solar heat,as shoum by a small temperature rise.It is defined so that ( P )P y a standard black(reflectance 0,05,emittance 0.90)Is 0 and a standard white(reflectance independent analytical laboratory. 0.80,emittance 0.90)Is 100.Materials with the highest SRI values are the coolest choices for rooting.Gusto the way SRI is defined,particularly hot materials can even take slightly 4. Sure-Weld TPO was tested for dynamic puncture resistance per regimes values and particularly coal materials can even exceed 100. ASTM D5635-04 using the most recently modified impact head.45- *ENERGY STAR recommends that using the Roof Savings calculator(scorn g ed,which mil was watertight after an impact energy of 12.5 J(9.2 ft-Ibf)and factors In both heating and cooling costs,to determine whether a cool roof will be an energy 60-mil was watertight after 22.5 J(16.6 ft-Ibf).80-mil EXTRA was efficient choice for your geographic climate and building type. watertight after an Impact energy of 30.0 J(22.1 ft-Ibf). EED Information Pre-consumer Recycled Content 10% Post-consumer Recycled Content 0% Manufacturing Location Senatobia,MS Too ile,UT Carlisle,PA Solar Reflectance index(SRI) 99(white)86(tan) 800-479-6832 1 P.O.Box 7000 1 Carlisle,PA 17013 1 Fax:717-245-7053 1 www.carlislesyntec.com c*d Santa.I'll 600515-"Sure-Weld red Reinforced Membrane Product pate Sheet" ENERGY STAR is a nalste2dtrearrark owned by the U.S.Governmem-ENERGY STAR goinfikatan is only vend In the Ux. LEES is a registered trademark of the U.S.Green Building Council. CARLIBLE'S SURENELDO Sure-Weld®(TPO) Adhered Root-mg Systems Code Approval Guide January,2017 Table of Contents Introduction.................................................................................................................................................................................... ii Guidelines............................... ... ........:.................................................................................................................................... Sure-Weld Mechanically Fastened or Induction Welding Roofing Systems UL Approvals Non-Combustible-ANSI UL-Class A......... _............._..........._....._.__.._................-................._...................................................... 4 Combustible'-ANSI UL-ClassA.. __.... ........ ...... ,-> '.5 Combustible-ANSI UL-Class B... _........_. .......... ___..... ......_.. ._._._...._.. .. .................... 6 Combustible and Non-Combustible-ANSI UL-Class C............................................................_................................._.......__..................... 7 Existing UL Rating Retained .. ......... ......... ...... „..__.. 7 FM Approvals FM Approval-Field Sheet Securement Criteria........................ ..:.. :....-m. .......:........................ ....: :a.......... 8 FM Approval-Induction Welding Securement Criteria............................................................................................................................. 9 90 psf Uplift Resistance Test_............................................................_..........__........._....._............_.___.................__..........._._.................... 10 FMClass A Roof Deck....................................................................................................................................................................................... 11 ANSI-SPRI............._....-...................._._.........................._...._..................................... ............. _........_......................__........................................... 12 Sure-Weld Metal Retrofit Roofing Systems MetalRetrofit.........................................................................___........................._.::..................._.................._._..._._............_................... 13 Sure-Weld Adhered Roofing Systems UL Approvals Non-Combustible-ANSI UL-Class A.........................................................__..............._...................................................._................,....... 14 Combustible-ANSI UL-Class A..........................__...........................................................__...........__.................................................... 15 Combustible-ANSI UL-Class B.............................................................................__.........................,........._................................__........... 17 Combustible and Non-Combustible-ANSI UL-Class C_ .. - ........... , .......- - ......... ......... 18 FM Approvals SecurShieldHD New Construction..................................................................................................................................................._.........- 19 SecurShieldHD Recover................___......................................:............_........................................................_.........................:.................... 21 SecurShieldHD Plus New Construction...................................................................................._.............._....::......._..__..........................._... 22 SecurShieldHD Plus Recover...................................................................................._...............__..............._._................................................ 24 InsulBase Polyiso New Construction..................................................................................................._............................................................ 25 InsulBasePolyiso Recover......................................_............................__................................................................................ ....._. 27 SecurShield and SecurShield HD Composite New Construction...................................................................................................................... 28 SecurShieldRecover............................................... _ _ _ .......... ........................................... .............._.._.......... .._....................... ............ _... ........ 30 SecurockNew Combruction................._............................................................................................................................................................ 31 SecurockRecover............................................................................................................................................................................................... 33 DensDeckPrime New Construction.......................... .............................................._...................._.................:........................................... 34 DensDeckPrime Recover..........___...............................................__......_................................_................_.............................................. 36 OSBNew Construction...................................................._......._..................-_.............................................-......._....._.........._....................... 37 OSBRecover...................................................................................................................................................................................................... 38 HPRecovery Board New Construction............................................................................................................................................................... 39 I-IP Recovery Board Recover............................................................................................................................................................................... 41 Lightweight...._..................._............................... .............. 42 ................................................................................................................................. National,State&City Building Code Approvals....................................................................................................................... 43 DadeCounty(South Florida)Approvals........................................................................................................................................ 43 ReferenceNotes......................................................................................................................,.................................................... 44 600163-SW Codes i 01/2GO Sure Weld®(TPO);Mechanically-Fastened'or Induction Welding B Y Roofing 5 stems UL Approval-Combustible-ANSDUL 790 Spread of Flame Test(Class A) .045-or.060"Sure-Weld Standard Reinforced Membrane(Wbitq Gay,or Tan) Membrane 045"or.060"Sure-Weld HS ReinforcedMwbmne(V✓lilte,Gray or Tan) Type: 080"Sure-Weld EXTRA Reinforced Membrane(White,Gray or Tan) a60"or 080"Spectra-Weld Reinforced Membrane(Mme) Cumbnsfible:9/16-in.(mvumumj thick non-veneer APA-rated sheathing(oriented sound board panels,structural particleboard panels,composite panels or wsferboard panels);15n2-m. (min um)thick plywood 3/4 in(minimum)wood;Term.Qess than S"thick) Combustible ANSI/UL 790 Spread of Flame Tet-UassA " Minimum IX'SECUROCR eUry ilL Clmsif�ed Carlisle Polyisocyanmale Insulationany I Gypsum Fferor Glass Mat Roof ombiretioq any thickness. N/A t/2" 1/2" Boards(1) c 2 Minimum l/4"DedaDeek/Dvm1)ek Any IM Classified Carlisle Polyisocyanmate fsWafion,arry N/A 1/2" 1/2" Prime RoofBoards(1) cimbioati.,any thickness. 3 N/A Minimum 3"lays,m-find layers of 1-1/2"SecmShield or N/A 12" 12" SemaShicRIMComposim.(1)(3) M inimnm 2-1/2"layer SecmShield or SecmShield HD 4 N/A Composite over a 2-1/2"(minimum)layer of Cmhahc N/A 12" 1/2" IosWease Insulation.(1)(4) 5 Carlisle FRBase Sheet Minimum l.9"layer of SecmShield ar SecmShield HD N/A 12" 1/2" Composite.(1)(4) Minimum 2-12"layer of arty UL Classified Carlisle Minimum 1/2"SecmShieldM 6 N/A Polyismiyanuratelnsulation,any combination-(1) or SecmShield HD Plus 1/2 I/2 7 Carlisle FR Base Sheet MSWmum L4"layero£a,UL Classified Carlisle Mhnimnm 1/2"SecmShield DD 11 1W Polyisisquourate Insulation,any combiname-(1) or Se cur Shield HD Plus 8 N/A Minimum l"layerof SecmShield CD. (1)(5) N/A 12" 1/2" 9 N/A Minimum 4"layer of any UL Classified EPS Insulation. Minimum IX SecuShield M 112" I/T, (1)(6) mSeanrShmdHDPlas 10 N/A Moorman I"layer ofSecurShoeld CD over a minimum 3-IC' N/A 12" 1/2" laycrofany UL Chroolad EPS Insulation (1)(6) Minimum 1-12"laym offrealfoamHD Composite over a 11 N/A minimum 3"Iayeroflnsuifoam E'S.(1)(6) N/A. 1/2" 12" Minimum 2"layer.f`1mmlfmmM Composite aveia- 12 N/A mini2-1/2"IayeroflavWfam CPS. (1)(6 N/A I/2" IL-1 13 N/A A^y Classified Carlisle Polyisocyanuratelaaulafiaga y Minimum 1/4"SECUROCKO 3" 3" combination,any thickness. Gypsum Fiber RoofBoard(1) 14 N/A Am UL Classified lnsWatiors any thickness(OPTIONAL) Mrnimum3/8"SECUROCK® 3" 31, GypsumFiber ROOfBoard(1) 15 N/A Arry ULClass ified Insulation,any thickness(OPTIONAL) Minimum 1/2"SECUROCKO 3" 3" Gypsum Fiber RoofBomd(1) 16 One Ply of Type G2 Any IM Classified fsulatioo,any fiiclmess(OPTIONAL) Minimum IN'SECUROCK® 3" 3" Gypsum Fiber Roof Board(1) V N/A Any TIL Classified Insulation,any thickness(OPTION MTirwnunlN'SECUROCKO 3"-Sure-WWdAL) Sure-Weld Worried Unlimited Glass Mat RonfHoard(I) EXTRA Minimum l/4"Dens 3"-Snro-Weld 18 N/A Any UL Classified Insulation,any tluckness(OPTIONAL) Deck/DensDeck Prime Roof 2-1/2"-Sumweld Unlimited Be.&(1) EXTRA Two layers ofCarlisle FRBase Arty UL assi e wise o rsmadurn a e u a um mry 19 Sheet cortmactnn,any thickness. N/A 12" 12" <<TABLE OF CONTENTS �oo16s—s ate SURE-WELD@ TPO Reference Notes 1. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly. (return to table) 2. Any roof covering system listed for use over a combustible roof deck can be installed aver a non-combustible roof deck and achieve the same classification.(return to table) 3. Any UL Classified Carlisle Polyisocyanmate Insulation,any combination,any thickness may be used below the 3"minimum total thickness of SecurShield or SecurShield FID Composite. (return to table) 4. Any UL Classified Carlisle PolyisocyanmaW Insulation,any combination,any thickness may be used below the 1-9/10"thickness of SecurShield or SecurShield HD Composite. (remm to table) 5. Any UL Classified Carlisle Polyisocyanmate Insulation,any combination,any thickness may be used below the 1"thickness of SecurShield CD. (return to table) 6. Any UL Classified Insulation,any combination,any thickness,maybe used below the 4-1/2"minimum total thickness. (return to table) 7. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 8. Any thickness of UL Classified Carlisle Polyisocyanurate Insulation may be used belowthe 1-9/10"thickness of SecurShield or SecurShield HD Composite. (rerun to table) 9. Any UL Classified insulation,any combination,any thickness,may he used below the SecurShield CD. (return to table) 10. For roof deck construction(new,tear-off or retrofit),approved insulations and maximum roof slopes,click here. (return to table) 11. Refer to Carlisle specifications for minimum requirements regarding sheet widths and fastener spacing. (return to table) 12. On steel decks,Carlisle HP-X Fasteners and Piranha Plates or HP-Xtra Fasteners and Piranha Xtra Plates we required as identified in this chart. On structural concrete decks,CD-10,HP Concreate Spikes or HD 14-10 Fasteners are used with Piranha Plates. (return to table) 13. Testing conducted on FM approved 22-gauge Grade E Steel decking(ASTM Designation A611 or A653 Grade 80). Refer to FM requirements for deck installation. (click here for FM requirements)(return to table) 14. Ratings achieved using steel decking attached to structural purlins spaced 5'o.c. (remm to mble) 15. Please reference for ANSI-SPRi WD-I/ASCE 7-10 for non-FM insured projects,click here. (return to table) 16. For roof deck construction(new,tear-off or retrofit),approved insulations and maximum roof slopes,click here. (tenor to table) 17. On steel decks,Carlisle IIP-X Fasteners and Piranha Plates or HP-Xtm Fasteners and Piranha Xha Plans are required as identified in this chart. On structural concrete decks,CD-10,HP Concreate Spikes or HD 14-10 Fasteners are used with Piranha Plates. (return to table) 18. The fastener spacing for membrane securement is dependent on the deck type,desired wind uplift rating and the Carlisle Fastening Plate and Fastener utilized as identified,click here for more information. (return to table) 19. Insulation shall be fastened in accordance with Carlisle Specifications. (return to table) 20. On steel decks,a thermal barrier of FM approved gypsum board is required under expanded or extruded polystyrene. For specific therrnal barrier requirements,refer to FM''s RoofNAV web-site. (return to table) 21. Existing roof must be FM Class l rated. (rehmi to table) 22. Sure-Seal HP fastener/Sure-Seal Insulation plate. Click on one of the fnllowing to return to chart: SecurShield HD,SecmShield HD Plus, 23. Insu1FAST fastener/Sure-Seal Insulation plate. hrsuMase Polyiso,SecurShield,SecurShield HD Composite,Secrrock,DensDeck Prime, J 24. Insu1FAST fastener/SecurFAST Insulation Fastening plate. OSB or HP Recovery Board 25. All insulation joints must be staggered a minim=of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 26. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to Table) 27. Any UL Classified Carlisle Polyisocyanurate Insulation,any combination,any thickness may be used below the 3"minimum total thickness of SecurShield or SecmShield HD Composite. (return to table) 28. Any UL Classified Carlisle Polyisocyanumte Insulation,any combination,any thickness may be used below the 1-9/10"thickness of SecmShield or SecurShield HD Composite. (return to table) 29. Any UL Classified Carlisle Polyisocyanuratc Insulation,any combination,any thickness may be used below the 1"thickness of SecurShield CD. (return to table) 30.Any UL Classified Insulation,any combination,any thickness,maybe used below the 4-1/2"minimum total thickness. (return to table) 31, All insulation joints most be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 32. Any thickness of UL Classified Carlisle Polyisocyanmate Insulation may be used below the 1-9/10"thickness of SecurShield or SecurShield HD Composite.(retain to table) 33. Any UL Classified insulation,any combination,any thickness;may be used below the SecurShield CD.(return to table) 34. 80 lost with one fastener per attachment point.(return to table) 35. 80 ksi with two frsterners per attachment point.(return to table:SecurShield HD Plus,DensDeck Prime or SecurShield) «TABLE OF CONTENTS t 600163-SW Codes page 44nf44 01/2017 Aitk Georgia-Pacific DensDeck® Technical Service Hotline 1.800.225.6119 or Roof Board www.densdeck.com Manufacturer Georgia-Pacific Gypsum LLC 133 Peachtree Street,8th floor,Atlanta,GA 30303 Technical Service Hotline 1-800-225-6119 or www.densdeck.com Description Dru sDecV Roof Board is an exceptional fire barrier,thermal barrier.coverboard and recovery board used in various commercial roofing systems.The patented DensDeck design employs glass mat facings front and hack that are mechanically bonded to a water-resistant .. gypsum core,providing excellentfire resistance,moisture resistance and wind uplift properties.The unique construction of DensDeck provides superiorflute spanning that stiffens and provides increased foot traffic resistance to the roof deck.Additionally,DensDeck has been shown to withstand delamination,deterioration,warping and job-site damage more effectively than roofing membrane substrates such as paperfaced gypsum board,fiberboard and perlite insulation.DensDeck is highly resistant to the growth of mold when tested,as manufactured,per ASTM D 3273. Primary Uses Roof system manufacturers and designers have found DensDeck Roof Board to be compatible with.many types:of roofing systems, - including:built-up,modified bitumen,single ply,metal systems,wood shingle and shake,tile,slate,as well as a recovery board and overlayment protection board for polyisocyanurate and polystyrene insulation.DensDeck can also be used as a form board for poured gypsum concrete deck in roof applications as well as a substrate for spray foam roofing systems.1/2"and 5/8"DensDeck may also he used in vertical applications as a backer board or liner forthe roof side of parapet walls. Some membrane manufacturers have hot map asphalt or torch applications directly to DensDeck without using a primer or base sheet.Consult with the system manufacturer for their recommendations with this application.System manufacturers and designers have found DensDeck to be compatible with bonding adhesives for fully-adhered single-ply membrane applications.DensDeck's exceptional moisture resistance and low R-value make it the preferred substrate for vapor retarders. An excellent fire barrier,DensDeck features a noncombustible core and inorganic surface that offers greater fire protection than other conventional commercial roofing products when applied over combustible roof decks and steel decks.DensDeck is FM tested. Limitations DensDeck Roof Board is designed.to act with a properly designed roof system.The actual use of DensDeck as a roofing component is the responsibility of the roofing system's designing authority.Georgia-Pacific does not offer roofing system design services. Conditions beyond the control of Georgia-Pacific such as weather conditions,dew,application temperatures and techniques may cause adverse effects with adhered roofing systems. Consult roofing manufacturers for their specific instructions on applying their products to DensDeck. 1, The need for a separator sheet between the DensDeck and the roofing membrane shall be determined by the roof membrane manufacturer or roofing systems designer. DensDeck roof board products may have temporary factory-applied packaging(plastic wrap)that must be removed upon receipt to prevent accumulation or entrapment of condensation or moisture which may cause application problems.Provide other suitable breathable weather protection for storage to keep DensDeck products dry. Panels must be kept dry before,during and after installation.Apply only as much DensDeck as can he covered by a roof membrane system in the same day. Accumulation of water due to leaks or condensation in or on DensDeck must be avoided during construction and after construction. Avoid over-use of non-vented direct-fired heaters during winter months.Avoid application of DensDeck during rains,heavy fogs and other conditions that may deposit moisture an the surface.When applying solvent-based adhesives or primers,al low sufficienttime for the solvent to flash off to avoid damage to roofing components.Maximum flute span is 2-5/8"for 1/4"DensDeck;5"for 1/2" DensDeck and 8"for 5/8"DensDeck Fireguard®Type X. For vertical parapet applications,1/2"DensDeck can span 15"no and 5/8"DensDeck can span 24"oc. DensDeck,DensDeck Prime and DensDeck DuraGuard roof boards should not be subjected to abnormal or excessive loads or foot traffic such as on plaza decks or under steel wheeled equipment that may fracture or damage the panels.Provide suitable roofing system protection when required. Submittal Job Name Approvals Contractor Date Georgia-Pacific Dens®eeka Technical Service Hotline 1.800.225.6119 or Roof Board www.densdeck.com Technical Data Flame spread 0,smoke developed 0,when tested in accordance with ASTM E 84 or CAN/ULC-S702.Noncombustible when tested in accordance with ASTM E 136. DensDeck Fireguard:UL Classified when tested in accordance with ASTM E 119.5/8"DensDeck can replace any generic Type X gypsum board in any roof assembly in the UL Fire Resistance Directory under the prefix"I"'. 1/4"DensDeck has been tested by Factory Mutual for 60 psf and 90 psf wind uplift for BUR,EPOM,thermoplastics and modified bitumen roof systems.Higher wind uplift ratings have been achieved by numerous membrane manufacturers using DensDeck in their FMRC-approved construction designs. DensDeck is FM tested and approved as the only 1/2"gypsum product to meet the calorimeter requirements for conventionally insulated decks. Miami-Dade.County,Florida NOA 07-0124.02 Thickness,nominal 1 +1/16" 11/2"±1/32" 5/8"±1/32" Width,standard 4'±1/8" 14'±1/8" 4'±1/8" Length,standard 4'and 8'±1/4" 14'and6'±1/4" 4'and 8'±1/4" Weight,lbs./s .R,nominal 1.1 1.95 2.5 Surfacing Fiberglass mat Fiberglass mat Fiberglass mat Flexural Strength',parallel,lbs.min. 40 :80 100 Flute S ar ili ' 2-5/8" 5" 8" Permeance',Perms 50 35 32 "H"Value' .28 .56 .67 Linear Variation with Change in Temp.,in/in°F 8.54 D' 18.5x104 B.5x1 V Linear Variation with Change in Moisture,in/in%RH 6.25x1V 6.25xlV 6.25xlV Water Absorption',%max 10.0 10.0 10.0 Compressive Strength,psi nominal 500-9DO 1 500-900 500-900 Surface Water Absorption',grams,nominal <2.5 1<2.5 <2.5 Flame Spread,Smoke Developed(ASTM E RAI O/D 10/O 0/0 Fire Classification FM CLASS 1 1 FM CLASS 1 (FM 4450) FM CLASS 1 (FM 445D( (as overla ment) I. UL 1256,ULC S-126 UL 1256,ULC S-126 UL 1256,ULC S-126 UL Class A(UL 790) UL Class A(UL 790) UL Classified"P"assemblies ULC S-107 ULCS-107 ULC Classified"R"assemblies ULC S-101 Class A(UL 790),ULC S-107 Mold Resistance per ASTM D 3273' Mold resistant Mold resistant Mold resistant ASTM Standard C 1177 C 1177 C 1177 Uplift Standards and Testing ANSI/UL 1897 'ANSI/UL 1897 ANSI/UL 1 B97 ASCE 7 ASCE 7 ASCE 7 FM 4470 FM 4470 FM 4470 Bending Radius 5' 8' 12' 1. Tested in accordance with ASTM C 473 4. Tested in accordance with ASTM C 516(heat flow meter). 2 farmers accordance lend ASTM E861(4001b.cant.load only for IP'and 5/8'). 5.ASTMC 1177 minimums. 3 Tested in accordance with ASTM E-96(drycup method). 6. When tested as manufactured in accordance with ASTM D 3273. TRADEMARKS LIMITATION OF REMEDIES SAFETY CAUTION:This product The GEORGIA-PACIFIC logo and all AND DAMAGES contains fiberglass.Fibers and dust Georgia-Pacific trademarks are owned by or licensed Unless oNerwise stated in our written may be released from this product Gypsum to Georgia-Pacific Gypsum ULC. limited warranty for this product,our during normal handling and may UPDATES AND CURRENT sole liability for any product claimshall result in skin,eye and respiratory SALES INFORMATION AND ORDER PLACEMENT INFORMATION be limited to reimbursement of the irritation.Avoid breathing dust and U.S.A. Midwest: 1-800-876-4746 West: 1-800-824-7503 The information in this document cost of repair or replacement of the contact with the skin and eyes.Follow South: 1-800-327-2344 Northeast: 1-800-947-4497 may change without notice. affected product,.up to a maximum these standard work practices:Wear y g amount of two Goes the original a loose4ifting,long-sleeved shirt currentit our Waamon.for updates and theand long ants,protective gloves CANAOA Canada Tall Free: 1-BUU-361-0486 current information. purchase shall not affected 9P Quebec Toll Free: 1-800-361-0486 product We circumstances ererlast file and eye parwith (Daggershield).of Weafety rs under anycircumstances for lost glasses with side shields).Wears Profits,damage to a structure or its dust mask when sanding.Additional Georgia-Pacific Gypsum Technical Hotline contents,or indirect,incidental, protection may be needed when very U.S.A.and Canada:1-800-225-6119 special or consequential damages. dusty,Do not uae a power saw. Mon.-Fri.,8 am.-5 p.m;ET Claims shall be deemed waived it -For Material Safety Data Sheet they are notsulmiaed to us In writer or additional information,call within ten days after discovery. 1-BW-225-6119 or visit our Web side. ©2007 Georgia-Pacific Gypsum LT.All rights hundreds.Printed in USA.Rev.11/07 Lit.Item#1 m 516. 0- CIO J:7- fly, \ � per] ` } \ \} / } ) � Min H �� THERMOPLASTIC MEMBRANE PVC/TPO� NOTES: SEALANT HOT AIR WELD, 1. WOOD NAILER MUST CUT-EDGE 1-1/2" (38mm) MIN. EXTEND PAST TOTAL I WIDTH OF METAL FASCIA I I DECK FLANGE. COATED METAL ' 2. APPROXIMATELY 1/8" FASCIA I I I I (3mm) DIAMETER BEAD MINIMUM WOOD NAILER (BY OTHERS) ❑1 SF REQUIRED ONEALANT CUT 22-GAUGE 1-1/2" (38mm) RING SHANK EDGES OF REINFORCED CONTINUOUS NAILS ® 6" (152mm) O.C. TPO MEMBRANE AND CLEAT RECOMMENDED ON CUT EDGES OF SURE-FLEX PVC MEMBRANE. 1 2 INSTALL CONTINUOUS CLEAT AND COATED HEAT WELD 3" (76mm) WIDE PIECE OF METAL WITH 1/8"-1/4" (3-6mm) JOINTS NON-REINFORCED THERMOPLASTIC BETWEEN ADJOINING SECTIONS. MEMBRANE OVER JOINT f. 3 4 . .... ..... ..... .. . . .......... .. . ..w CUT-EDGE SEALANT HOT AIR ❑2 WELD 1-1/2" MIN. HEAT WELD 6" (152mm) WIDE PIECE OF POSITION FIELD MEMBRANE AND HEAT WELD NON-REINFORCED MEMBRANE OVER JOINT COATED METAL A MINIMUM OF 1-1/2" (38 mm) AS SHOWN. THERMOPLASTIC SIIC REINFORCED SecurWELD COATED DRIP EDGE NF_'� AIL N0. -� APPROVED INSULATION FASCIA —. SEE NOTE(S) For additional information, refer to Specifications Ti{ERMOPLASTIC UNIVERSAL © 2017 Carlisle SynTec a division of Carlisle Construction Materials Incorporated THERMOPLASTIC MEMBRANE PVC/TPO� 3/4" (19mm) TO B" (2�) t I 3 1 STAINLESS STEEL x .. �q WATER CUT-OFF CLAMPING RING a MASTIC INCLUDED x - !0 ; x THERMOPLASTIC l� PRE-MOLDED PIPE FLASHING I HOT AIR-WELD, 1-1/2" - (38mm) MIN. BEYOND I FASTENING PLATES I I I l � AR IS E FASTENER & SEAM FASTENING PLATE, MAX. 12" (305mm) D.C. ,.. .1 F4 5 I I NOTES: i 1. REMOVE ALL EXISTING LEAD AND FLASHING MATERIAL BEFORE INSTALLING PRE-MOLDED PIPE FLASHING. 2. TEMPERATURE OF THE PIPE PENETRATION MUST NOT EXCEED 140-F (60-C) WHEN USING PVC AND 160-F (71-C) WHEN USING TPO FLASHING.. 3. PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE, REGARDLESS OF PIPE DIAMETER. 4. INSTALL A MINIMUM OF 4 FASTENERS AND PLATES AROUND THE PIPE, EQUALLY SPACED. IF FASTENERS AND PLATES CANNOT BE INSTALLED AS SHOWN, THEY MAY ALSO BE POSITIONED OUTSIDE THE PIPE MAXIMUM 12" (305mm) O.C. AND FLASHED WITH THERMOPLASTIC REINFORCED MEMBRANE/CUT-EDGE SEALANT. REFER TO DETAIL U-8B. 5. FASTENERS AND PLATES ARE NOT REQUIRED ON ADHERED SYSTEMS UNLESS PIPE DIAMETER EXCEEDS 18" (457mm). 6. ON MECHANICALLY FASTENED SYSTEMS, HP-X FASTENERS AND PIRANHA PLATES OR HP-XTRA FASTENERS AND PIRANHA XTRA PLATES ARE REQUIRED OVER STEEL AND WOOD DECKS. ON CONCRETE DECKS, CD-10 OR HD 14-10 FASTENERS ARE USED WITH PIRANHA PLATES. �--. THERMOPLASTIC REINFORCED DETAIL NO. MEMBRANE PRE-MOLDED PIPE FLASHING APPROVED INSULATION �:'-', ❑p SEE NOTE(S) For additional information, refer to Specifications THERMOPLASTIC UNIVERSAL 2017 Carlisle SynTec a division of Carlisle Construction Materials Incorporated t•THERMOPLASTIC MEMBRANE PVC/TPOI• 9A MECHANICAL TERMINATION WITH COUNTER FLASHING NOTES: CARLISLE UNIVERSAL SINGLE—PLY SEALANT OR SEALANT (BY OTHERS) 1. APPLY ON HARD SMOOTH SURFACE ONLY; NOT FOR USE 1 METAL COUNTER—FLASHING (BY OTHERS). ON EXPOSED WOOD. r CARLISLE HP TERM BAR NAIL—IN 2. DO NOT WRAP TERMINATION BAR CARLISLE TERMINATION BAR AROUND CORNERS. j MIN. i/4" (6mm) 3. DETAIL REQUIRED FOR USE ON I WARRANTY PROJECTS EXCEEDING 20—YEARS. --w-JI-*— MAX. 1/2" (13mm) 9B SHEET METAL COPING(BY OTHERS) NOTES: 1. FOR CARLISLE SecurEdge METAL CAP (BY COPING, REFER TO INSTALLATION ___ _ OTHERS), SLOPE INSTRUCTIONS PUBLISHED DOWNWARD SEPARATELY. i TOWARDS ROOF EXTEND I 2 2. MEMBRANE MUST BE EXTENDED MEMBRANE TO CORNERS TO PROVIDE BELOW JOINT COMPLETE COVERAGE OF THE TOP WALL SURFACE. 9C COUNTER FLASHING TERMINATION NOTES: 1. WHEN MECHANICAL FASTENERS ARE CARLISLE UNIVERSAL SINGLE—PLY USED TO PENETRATE THE METAL SEALANT OR SEALANT (BY OTHERS) COUNTER—FLASHING, USE EPDM WASHERS, APPLY WATER CUT—OFF METAL COUNTER—FLASHING (BY MASTIC UNDER THE OTHERS). COUNTER—FLASHING OR CAULK THE FASTENER HEADS. FASTEN MEMBRANE ® 12' (305mm) 2 DETAIL NOT FOR USE ON WARRANTY O.C. MAX. PROJECTS EXCEEDING 10—YEARS. 9D MECHANICAL TERMINATION NOTES: 1. APPLY ON HARD SMOOTH SURFACE ONLY; CARLISLE UNIVERSAL NOT FOR USE ON EXPOSED WOOD. SINGLE—PLY SEALANT OR SEALANT (BY OTHERS) 2. DO NOT WRAP COMPRESSION TERMINATION BAR AROUND CORNERS. CARLISLE HP TERM BAR x f NAIL—IN. 6" (152mm) 3. DETAIL NOT FOR USE ON WARRANTY x O.C. FASTENING PROJECTS EXCEEDING 20—YEARS. RECOMMENDED CARLISLE TERMINATION IN r� MIN. 1/4" (6mm) BAR CED. '. . --m—AL� MAX. 1/2" (13mm) APPLICABLE BONDING ADHESIVE. USE OF WATER CUT—OFF MASTIC— MUST BE -- CAA—GRIP MAY ALSO BE USED FOR UP TO 20 xxx YEAR WARRANTY HELD UNDER CONSTANT COMPRESSION. � THERMOPLASTIC REINFORCED DETAIL NO. MEMBRANE MEMBRANE TERMINATIONS APPROVED INSULATION PAGE 1 OF 2 U_9 �p — SEE NOTE(S). For additional information, refer to Specifications hiERMOPLASTIC UNIVERSAL © 2017 Carlisle Syn Tec a division of Carlisle Construction Materials Incorporated