Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0357 1609 R Avenue (4) . A CCESS R o� CITY OF ANACORTES -S 7�0q-24,, PL A`NNING AND BUILDING DE : : 2013z — — _ APPROVED PLANS GRASS - - REVIEWED FOR CODE COMPLIANCE • RMIT#: BLD 2020 0357 • . . • • • • • • . • • . • ADDRESS: 1609 R Av- _ ILVERT ( / / / / / / / / / / / / APPROVED BY: 1 % TO SFWFR( SWALE REMOVE HVAC GRAVEL SWALE �� GRASS I SUBJECT TO FIELD INSPECTION.APPROVED PLA S SH' OT CD FIRE HYDRANT M SANT ` REMOVE & RELOCATE LIGHT POLE ��oo t f r I BE ALTERED WITHOUT AUTHORIZA ON. 44 P s ys yAC' 1 0 10 S 30 40 50 REWORK EXISiINGf �� �� DUCT WORK s � SCALE y��- REMOVE • CONCRETE SLAB I :__'k,'_ 1 42 / 41 W I L.,�, I EXISTING PERCENT OF LOT COVERED REMOVE HVAC I 40 • LOT AREA 48912 SQ. FT. 00 BUILDING & COVERED PORCH 11467 SQ. FT. z {lj �lEi 67 43 • 39 cog, PERCENT OF COVERAGE 23.4 X � IREWORK EXISTING * :Si . [1] DUCT WORK F,'�t . fJ 38 • • I I 68 66 44 A EXISTING IMPERVIOUS AREA Q 37 BUILDING & COVERED PORCH 11467 SQ. FT. 65 45 ,`�' DRIVEWAY, PARKING AREA, AC CONCRETE PADS 21355 SQ. FT. I 69 121 36� TOTAL 32822 SQ. FT. /(TYPICPAO T 70 64 46 01 o PERCENT OF EXISTING IMPERVIOUS 67,1% EXISTING BUILDING 63 47 35Q 71 62 48 ASPHALT NI 34 fZ ASPHALT r�2NN I //// 133 i 61 49 32 I / so 50 31 DRAWING INDEX: ® 59 52 . 1. EXISTING SITE PLAN I. 30 2. NEW SITE PLAN I. 58 53 1 3. EXISTING & NEW ELEVATI❑NS 29 4. EXISTING & NEW FLOOR PLAN i 5. FOUNDATION PLAN �A �P 57 54 28 6. ROOF PLAN I. 4 -110,_ '4' I 56 55 27 PAFKING ' LEASED 7. SECTI❑NAL DETAILS 25 26 • S It. / 1 I C li * ) d -,:rr cog.. 1 I ASPHALT /-i e \i li* \1 SCALE: 1' =30'-0' ON 11' x 17' PAPER I._ ** LEASED PARKING i 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 EXISTING SITE PLAN THRIVE HEALTH CLUB ADDRESS: 1606 R AVENUE GRASS I PARCEL: P 118625 /•,_ _ . _ _ . _ _ . _ _ . _ _ 5 89a 59488"E_ _ . _ 4 XrefiD 350219-0-040-0100 194.00 DRAWN BY: BRUCE RUSTAD DATE: 06/05/20 1 ;i67-- . CCESS R �A ED • —S�00'24- �..�L-- _ 201.32' _ r1 — �� — -20'sET GRASS —840( _ 20' SET BACK _ GRASS "eMP C235 "" "" . . "u% • . . . . . 0 10 20 30 40 50 _ _ _ _ I STRAW WATTLE CULVERT \� TO STORM SEWER SWALE SWALE J SCALE CUCl�HEMP UNIT ELOCATED FIRE HVANT . . . . . LIGHT I ° WpLL�N t°B 25'-0' �s DUCT OPENING lL5'W""2 HOUR ,�{�� I FIRE WALL '/ E EITIC Q HEW HVAC 1 VCCc EXISTING PERCENT OF LOT COVERED UDC �_4�i N ROOF �,'�" LOT AREA 48912 SQ, FT. INSTALL 1-1/2 HR FIRE RATED HVAC DAMPER \i�Fw- BUILDING & COVERED PORCH 11467 SQ. FT. zxe WALL w/2 LAVERS OF scuB(3RRQDODW11JSPauT PERCENT OF COVERAGE 23.4 % REMOVE EXISTING WINDOW 5/8"GYP.BD.BOTH SIDES PIPE TO EXISTING SWALE ��lCyillT`h�'�' INSTALL NEW 1-1/2 HR FIRE RATED WINDOW OF RxFI STUDS . 2 HOUR FIRE WALL SEE SECTIONAL DRAWING 42 _——°—,—. FOR DETAILS REMOVE EXISTING WINDOW , INSTALL NEW 1-1/2 HR FIRE RATED WINDOW ' EXERCI ROOM ' W I A .E 49'-6 x25' �NWCURS 41 . NEW PERCENT OF LOT COVERED DOOR&RELOCATE 1237.5 SQ. FT. HE INTO w/EXIT SIGN ''')I � 0 40 LOT AREA 48912 SQ. FT. EH Arc ul1— BUILDING & COVERED PORCH 11467 SQ. FT. Duc _c XII ON ROOFC ADDITION 1237.5 SQ. FT. r"' DUCTLESS TOTAL 12704.5 SQ. FT. z INSTALL 1-1/2 HR FIRE RATED HVAC DAMPER 5'*-+. HEATING UNITE 67 43 • 39 • Li_ I•3 U WALL-IN I ' _ * ¢ PERCENT OF COVERAGE 26 u DUCT OPENINGS FIREOWALL RIACK o NOTES: \ �� 66 as N 38 '�U I�i� 3 1. EXISTING 6 NEW IMPERVIOUS AREAS ARE THE SAME T NEW 3'-0"DOO' '� 68 65 45 37 c� IN �f 69 2. NO NEED FOR BMP C105 STABILZED CONSTRUCTION ENTRANCE 36 ENTRANCE IS ON EXISTING APHALT DOWNSPOUT �� 64 46 0 0 3, CONCRETE AND DIRT TO BE HAULED AWAY to (TYPICAL) �.. 70 NO NEED FOR BMP C154 CONCRETE WASHOUT AREA M f EXISTING BUILDING J, 0 v 35v .7(TYPICAL) ` 63 47 NO NEED FOR BMP C123 DIRT WILL BE HAULED AWAY 0 71 ASPHALT 62 48 ASPHALT NI 34 4, DOWNSPOUTS 6, FOUNDATION DRAIN PIPING TO BE PIPED TO EXISTING SWALE 1 # !.r //// N1 33 5, NO NEED FOR BMP C120, BMP C123, BMP C124, 6, BMP C203 i61 49 32 BECAUSE SURROUNDING AREA IS ASPHALT. 11 j 60 50 Elr /// 59 52 31 DRAWING INDEX: j I 30 y1�i I% 1. EXISTING SITE PLAN 58 53 29 2, NEW SITE PLAN mFIRE HYDRANT 3. EXISTING & NEW ELEVATIONS P 7; 57 54 • 28 4. EXISTING & NEW FLOOR PLAN ' LEASED 5. FOUNDATION PLAN * I PAFKING 6, ROOF PLAN 56 55 27 25 26 7, SECTIONAL DETAILS II ASPHALT I E \ SCALE, 1' =30' 0° ON 11° x 17° PAPER Y I \\ REV. #1 07/13/20 LEASED PARKING NEW SITE PLAN i 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 THRIVE HEALTH CLUB I 20' SET BACK I ADDRESS: 1606 R AVENUE • PARCEL: P 118625 , _ , _ _ 5 89d 59' 48"E_ _ Xref iD 350219-0-040-0100 isa.00 — — — — — — — DRAWN BY: BRUCE RUSTAD DATE: 06/05/20 REPLACE WINDOW w/1-1/2 HR. RELO ATE LIGHT REPLACE WINDOW w/1-1/2 HR. FIRE RATED WINDOW FIRE RATED'WINDOW ❑ ❑ ❑ -- -- REMOVE HVAC \_i REMOVE HVAC ■■ T ffl .. \ REMOVE HVAC V- GRADE MM GRADE T.O.FINISH FLOOR /�/\/- �� C \\ �_ - GRADE GRADE - GRADE \ SWALE EXISTING SOUTH ELEVATI❑N EXISTING EAST ELEVATI❑N RELOCATE DOOR EXISTING NORTH ELEVATI❑N NEW EXERCISE ROOM NEW WINDOW w/1-1/2 HR ARE RATED WINDOW NEW WINDOW w/1-1/2 HR. OCATED LI - ARE RATED WINDOW ANEW HVAC I / 1 1 1 CliEW HVAC r-�I �, .I VAC NEW HVAC I I tt \ CEILING 13'-" -- L J -- _ HORIZONTAL SIDING -- ■■ ... ... ■■ ■■ pi1,i CORRUGATED METAL SIDING GRADE MM T.O.FINISH FLOOR =- GRADE 12110110 0010110110 0010 III ME GRADE \ N SWALE NEW 3,-0"DOOR NEW NORTH ELEVATI❑N NEW SOUTH ELEVATI❑N NEW EAST ELEVATI❑N SCALE. 1' =30'-0' ON 11' x 17' PAPER 410 REV. 1#1 07/13/20 EXISTING & NEW I SOUTH, EAST & NORTH ELEVATI❑NS THRIVE HEALTH CLUB ADDRESS: 1606 R AVENUE PARCEL: P 118625 )(refill: 350219-0-040-0100 DRAWN BY: BRUCE RUSTAD DATE: 06/05/20 EXISTING 2s-o• / MBCI INSULATED CORRUGATED 2x6®I6"CTRS.WALL GAS METER g^METAL Z GIRT METAL PANELS GAS METER 5'M w/2 LAYERS OF 5/8"OW.BD. DUCTLESS BOTH SIDES 0 2x6 HEATING UNIT 2 HR.FIRE WALL y// &R-21 INSULATION Qx \\\ r 7 Q O N'"' 9. ` II 4 �//////� SEE SECTIONAL DRAWING FOR DETAILS Ili \ r— \ / \ 1I1 HVAC ) �i I I I DUCT ) 9"METAL Z GIRT STORE FEXISRONTNG i WINDOW X`il_i SUPPLY ) EXISTING 10'x10' s n- Z�) \\ � STORE FRONT WINDOW •e I I I I r HVAC EF EXISTING -- -' 2x6 ALL" = IIII MBCI INSULATED CORRUGATED CTRS.WALLS I I I I I DUCT ) METAL PANELS _ w/5/8 GYP.BD.INSIDE RETURN 7 7/16 OSB OUTSIDE REUSE DUCTS &R-21 INSULATION REWORK TO CEILING _ ) SEE ELEVATION FOR SIDING REWORK GYP. BD. / REMOVE HVAC TIE INTO EXISTING DUCT O = AWALL-IN OPENINGS ® b '-IPP LY [pill I -----NEW HVAC 1-1/2 FIRE HVAC DAMPER ON ROOF _ EXISTING 10'x10'-- STORE FRONT WINDOW = -- I RETURN GA ®i. _ CTRS.WALLS EXISTING 1O'x10' w//8 GYP.BD.INSIDE STORE FRONT WINDOW 7/6"OSB OUTSIDE &R-21 INSULATION SEE ELEVATION FOR SIDING VAPOR BARRIER 2x6®16"CTRS.WALL EXISTING w/2 LAYERS OF 5/8"GYP.BD. 5/8"GYP.BD. _/ BOTH SIDES OF 2x6 8 HIGH 7 2 HR.FIRE WALL &R-21 INSULATION SEE SECTIONAL DRAWING FOR DETAILS EXISTING ) EXISTING 3"METHANE\ ) 3"METHANE ._ VENT PIPE \ ) VENT PIPE � . • NEW ) I EXISTING EXISTING EXERCISE R 0 0 V / STEEL COLUMN STEEL COLUMN -- 49'-6))) x 25' 1237.5 SQ. FT. EXISTING 10'x10'------ EXISTING 10'x10'------ STORE FRONT WINDOW STORE FRONT WINDOW • EXISTING 5/8"GYP.BD. IHL) RELOCATE DOOR&INSTALL 8 HIGH MBCI INSULATED CORRUGATED METAL PANELS CD 1-1/2 FIRE HVAC DAMPER — REMOVE DOOR & �- �_��� � RELOCATE TO NORTH WALL -hl" __NEW HVAC I r se NEW DUCT/ I' , RETURN ON ROOFME z r —- 2x6 ALL" I HVAC ) CTRS.WALLS i DUCT ) .. Y /w 5/8'GYP.BD.INSIDE x I SUPPLY 7/16"OSB OUTSIDE — L 3'x 6-8"DOOR b &R-21 INSULATION I ' PIT HVAC - w/EXIT LIGHT&PANIC BAR h SEE ELEVATION N FOR SIDING REUSE DUCTS o#IN 1 \\\\ REWORK TO CEILING R u N 7 F REWORK GYP. BD. �r1___�E � I-- � X p X X X X X X X 3"METHANE/ REMOVE HVAC VA N DUCTLES VENT PIPE )7 3VENTTPIPEE/. HEATING UNIT r7 2x6 0 16"CTRS.WALL WALL-N OPENINGS w/2 LAYERS OF 5/8"GYP.BD. BOTH SIDES OF 2x6 1 i 2 HR.FIRE WALL !=��� 7 !=^„ ! SEE SECTIONAL ID INSULATN RAWING IFFOR DETAILS A D D I T I❑\ FLIER PLA\ REMOVE EXISTING WINDOW(NEW) INDOW \❑PTHEAST C❑R\ER NEWW 3'x 6-8 DOOR w/EXIT LIGHT&PANIC BAR: SCALD 1/8' =1'-0' ON 11' x 17' PAPER 4 SCALD 1/4' =1'-0' ON 22' x 34' PAPER \ 4 of 7 EXISTI\G \-RTHEAST REV. #1 07/13/20 EXISTING NE CORNER FLOOR PLAN, C__ R\E R E L__❑R PLA\ & ADDITI❑N FLOOR PLAN ZONED CM-1 THRIVE HEALTH CLUB BUILDER TO VERIFY ALL DIMENSIONS ADDRESS: 1606 R AVENUE CONSTRUCTION NEEDS TO COMPLY WITH 2015 WASHINGTON STATE ENERGY CODE (WSEC) PARCEL: P 118625 BUILDING TO COMPLY WITH THE IRC 2015 BUILDING CODES XrefiD: 350219-0-040-0100 PLUMBING TO COMPLY WITH THE 2015 UNIFORM PLUMBING CODE DRAWN BY: BRUCE RUSTAD DATE: 06/05/20 1/2"x 10"A-BOLTS EXISTING c NEW 3"x3 x MB"GALV. WHR. EMBEDDED 7" ON 4'-0"CENTERS _ MIN.OF 2 BOLTS PER PIECE 25' i LOCATED NOT MORE THAN 12"FROM ENDS OR LESS FROM THAN EACH SEVEN END OOLT F PI DIE. 3-1/2" y T , NEW 5-1/2" CONC. SLAB REINFORCED w/ #4 @ 18" CTRS. EXISTING STEEL COLUMN EACH WAY FROM y • CO GRADE / #4 @ 18" CTRS. z_ 30 MIL PVC MEMBRANE 2" R-10 RIGID FOAM w/ WATER PROOF PROTECTIVE COVERING oo _ ON NORTH, EAST & SOUTH SIDES OF FOUNDATION • (3) #5 CONT. SPLICE LENGTH TO BE 30 TIMES THE REBAR DIA. A . . MIN. 3 TIES �, 2' EVENLY SPACED ALONG SPLICE DETAIL_ = 1 NOT TO SCALE • 2x6 STUDS @ 16" CTRS.. WALL 5/8"x 10"A-BOLTS NEW 5-1/2"CONC.SLAB BOTH SIDES OF 2x6 EMBEDDED 7" REINFORCED w/q4 0 18"CTRS.EACH WAY 2 HR. RATED FIRE WALL 3"x3'xi/4"GALV. PL.WHR. ON a'-o"CENTERS VAPOR 2 LAYERS OF 58" GYP.BD /BARRIER SEE SECTIONAL DRAWING FOR DETAILS MIN.of 2 BOLTS PER PIECE 2x6 STUDS @ 16" CTRS.. WALL LOCATED NOT MORE THAN 12"FROM ENDS 7/16"@ OSB SHEATHING EXISTING 5-1/2" CONC. SLAB OR LESS THAN SEVEN BOLT DIA.3-1/2" REINFORCED w/ #4 @ 18" CTRS. EACH WAY NEW 5-1/2" CONC. SLAB FROM EACH END OF PIECE 2X6(PT) REINFORCED w/ #4 @ 18" CTRS. EACH WAY Air 8d @ 6" CTRS. • EXISTING GRADE A 30 MIL PVC MEMBRANE #4 @ 18" CTRS. ( #5#4 @ 18" CTRS. m • :" IN. 4" SOLID A . — (2) #5 CONT. 6 MIL PVC MEMBRANE SPLIC)ELEN LENGTH TO BE • • yI• GRADED TO DRAIN BY 30 TIMES THE REBAR DIA. 2'-0"� GRAVITY TNG 36' x 12" THK. MIN. 3 TIES ROOF DRAINAGE TIE INTO EXIS wTJ(3) #5 WIDE EVENLY SPACED ALONG SPLICE 4" PERF. EXISTING ROOF DRAINAGE CODRAIN PIPE • ALLOWABLE BEARING PRESSURE: DETAIL#1 GRADGED RAVI YDRAIN BY 2000 psf for DEAD + LIVE WRAP IN FILTER FABRIC 2667 psf for DEAD + LIVE + (Wind or Sesimic) AND SET IN PEA GRAVEL DRAIN TO EXISTING SWALE • SECTI - \ AL- A- A L_ J EXISTING STEEL COLUMN F❑UNDATI❑N PLAN 5 SCALE 1/8' =1'-0' ON 11' x 17' PAPER 5 of' 7 SCALE: 1/4' =1'-0' ON 22' x 34' PAPER REV. #1 07/13/20 L FOUNDATIUN PLAN THRIVE HEALTH CLUB 3 \/vJ ADDRESS: 1606 R AVENUE ZONED CM-1 BUILDER TO VERIFY ALL DIMENSIONS PARCEL: P 118625 CONSTRUCTION NEEDS TO COMPLY WITH 2015 WAINIWITH LNGOT STATE ENERGY CODE (WSEC) X r e f i D: 3 5 0 2 1 9-0-0 4 0-0 1 0 0 BUILD ING TO COMPLY THE IRC 2015 BUILDING CODES PLUMBING 2015 UNIFORM CPLUMBI GI CODES DRAWN BY: BRUCE RUSTAD DATE: 06/05/20 $ 25—0' lr— • I Q A 3'—A- DOUBLE TRUSSES— CO Ur HV —4-__ _--------NEW HVAC REPLACE EXISTING'WINDOW w/ 1-1/2 HR.FIRE RATED WINDOW L i ENG.STEEL LATTICE TRUSSES SE 24"CTRS. SCUPPER w/DOWNSPOUT ROOF DRAINAGE TIE INTO EXISTING ROOF DRAINAGE (3 RROO 0 lo GHR. E EXISTING WINDOW w/ FIRE RATED WINDOW EXISTING MBCI INSULATED CORRUGATED METAL PANELS ii EXISTING METAL Z-GIRT SELF ADHERING WATER PROOF TAPE I (TPO)IRONED SEAM WATER PROOF MEMBRANE WATER PROOF MEMBRANE OR EQUAL 6"POL s0 GID FOAM INSUL. I���-' R-39 6"POLYISO RIGID FOAM ��"�y DOUBLE TRUSSES O AGAINST METAL TSIDING'I UNDER HVAC �"" 3 4T&G NEW H VAC 3/4 CDX 5-pLY • XTER(OR PLYWOOD I FIRE-RATED FIR(PT)PLYWOOD MIMMIIIIMIMIMEMIMIalMIMir CUT TO FIT 7010:EilhAGAINST METAL SIDING //�; /\ ENG.STEEL LATTICE TRUSSES®24"CTRS.k 0 2 LAYERS OF 5/8"GYP.BD. IIII 2 LAYERS OF 5/8"GYP.BD. EXISTING 2xfi 016"CTRS.WALL I \ MBCI INSULATED CORRUGATED METAL PANELS 12 ti ROOF PLAN DETAIL#1 NOT TO SCALE REPLACE EXISTING WINDOWS w/ 1.1 1-1/2 HR.FIRE RATED WINDOWS li (TPO)IRONED SEAM WATER PROOF MEMBRANE OR EQUAL I ' 3/4 TWO EXTERIOR PLYWOOD VAPOR BARRIER 6"POLYISO RIGID FOAM INSUL. FOAM INSUL.PANEL TAPERED CANT METAL COVERING R-39 FAS NERS STRIP STEEL COLUM� �i%%i/V//%//.%//.%//.%//.//I.///%/%l/V/I�111%%V//V//%//. � SCUPPER IP DETAIL#1 Ar6 DOWN SPOUT SCALE: 1/8" =1'-0' ON 11' x 17' PAPER EXISTING ENG.s eEL LATTICE TRUSSES®24"CTRS. 2xs®ts"CTRS.WALL SCALE: 1/4" =1'-0' ON 22' x 34' PAPER of 7 MBCI INSULATED CORRUGATED 2x4 016"CTRS.WALL WOOD TOP&BTM.CHORD METAL PANELS w/BOTH SIDE OF 5/8"GYP.GYP.BD. REV, #1 07/13/20 2 HR.FIRE RATING SEE SECTIONAL DRAWING FOR DETAILS ROOF PLAN DARING CRITERIA THRIVE HEALTH CLUB JROOT Live Load=25 psi(snow) ADDRESS: 1606 R AVENUE Dead Load=15 psi SECTI❑NALZONED FM-1 PARCEL: P 118625 BUILDER TO VERIFY ALL IPLYSIONS CONSTRUCTION NEEDSTO TO COMPLY WITH 2015 WASHINGTON STATE ENERGY CODE (WSEC) X r e f i D: 3 5 0 2 1 9—0—0 4 0—0 1 0 0 BUILDING WITH NG TO COMPLY WITH THE IRC 2015 BUILDING CODES 2015 BUNIFORM CPLUMBI GI CODES DRAWN BY: BRUCE RUSTAD DATE: 06/05/20 12 2 NEW HVAC TO BE MOUNTED ON ROOF 2 LAYERS OF 5/8" GYP. BD. PER HVAC SPECIFICATIONS WATER RESISTANT w/ JOINTS STAGGERED REPLACE EXISTING WINDOWS ON EXTERIOR SIDE SEE ELEVATION DRAWING w/ 1-1/2 HR. FIRE RATED WINDOWS (TPO) IRONED SEAM WATER FOR SIDING CALL OUT PROOF MEMBRANE OR EQUAL METAL GYP. BD. CORNER METAL COVERING w/ PEER TAPE & JOINT FINISH 6" POLYISO RIGID FOAM INSUL. 3/4 T&G EXTERIOR PLYWOOD R-39 '���., .i . 5 / FOAM INSUL PANEL FASTENERS II- � ! EXISTING n ' 2 DYERS OF 5/8" GYP. BD. ti 12 1/4 /SCUPPER w/ JOINTS STAGGERED STEEL COLUMN Y7A7/ / //lXl/ __ _ /__I-ll_VZ./z/v zLz zzzz �z , /Z Z V VMETAL GYP. BD. CORNER EXISTING EXTERIOR WALL w/ w/ FIBER TAPE & JOINT FINISH CORRUGATED METAL SIDING E:. EXISTING METAL Z-GIRT`_ VAPOR BARRIER R-21 INSULATION 3/4" CDX 5-PLY FIRE RATED FIR (PT) PLYWOOD ( 2 LAYERS OF 5/8" GYP. BD. -"\ ENG. STEEL LATTICE TRUSSES 0 24" CTRS. w/ WATER RESISTANTH!"I R-21 INSULATION BARRIER w/ WOOD TOP & BTM. CHORD JOINTS STAGGERED ERIDEED R-21 INSULATION 2 LAYERS OF 5/8" GYP. BD. II I s\ VAPOR BARRIER w/ JOINTS STAGGERED EXISTING 2x6 @16" CTRS. WALL , -----MBCI INSULATED CORRUGATED II E- METAL PANELS OVER NAILS & JOINTS R 21 INSULATION w/ FIBER TAPE & JOINT FINISH DOWN SPOUT EXISTING 10'x10' ______--------- TRS. WALL ...� STORE FRONT WINDOW 1 11 LAYERS OF 5/8" GYP. BD. 5/8" GYP. BD.-----_\ —7/16" OSB 2x6 @16" CTRS. WALL BOTH SIDES OF 2x6 2 HOUR FIRE WALL ATTACH BASE LAYER w/ 1-7/8" NAILS @ 6" CTRS. !NO.-Jo 2x6 (PT) SILL PLATE 5-1/2" THK. CONCRETE SLAB 2x6 (PT) SILL PLATE, �TTAC� FACE LAYER w 2 3 8 NAILS @ 8" CTRS. � GRADF E' / -4" SOLID PIPE FACE LAYER / ��4" PERF. PIPE REINFORCED w/ #4 @ 18" CTRS. EACH WAY 30 MIL VC MEMBRANE BASE LAYER 2 HOUR ERE WALL D-TA L NOT TO SCALE Equivalent to UL U301, Any penetrations of the 2 hr wall for electrical or plumbing to be Joints staggered 16". protected with a 2 hr rated listed assembly. Provide assembly number and details rior to SCALE. 1/4' =1'-0' ON 11' x 17' PAPER p SCALE. 1/2' =1'-0' ON 22' x 34' PAPER framing inspection if penetrations REV. #1 07/13/20 are made. SECTIONAL DETAIL THRIVE HEALTH CLUB ZONED CM-1 BUILDER TO VERIFY ALL DIMENSIONS ADDRESS: 1606 R AVENUE CONSTRUCTION NEEDS TO COMPLY WITH 2015 WASHINGTON STATE ENERGY CODE (WSEC) PARCEL: P 118625 BUILDING TO COMPLY WITH THE IRC 2015 BUILDING CODES Xre'FiD: 350219-0-040-0100 PLUMBING TO COMPLY WITH THE 2015 UNIFORM PLUMBING CODE DRAWN BY: BRUCE RUSTAD DATE: 06/05/20