Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-2019-0183 - Permit Set Plans - RESIDENTIAL INTERIOR ONLY REMODEL
.////, N\ N \ ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS OWNER PROJECT DESCRIPTION DRAWING INDEX & AND 719Q.AVEANACORTES HOUSING AUTHORITY INTERIOR RENOVATION OF TWO HOUSING UNITS AT THE ANACORTES"SITE 1 GENERAL �� AT © 719 Q.A COMPLEX." THE FIRST FLOOR AREA OF EACH UNIT IS 492 SQUARE FEET. THE SECOND ACT ACOUSTIC CEILING TILE ® DETAIL REFERENCE ANACORTES,WA 98221 FLOOR AREA OF EACH UNIT IS 511 SQUARE FEET. TOTAL GROSS SQUARE FEET OF THE G0.00 COVER SHEET AFF ABOVE FINISHED FLOOR PROJECT IS 2003. G0.01 PROJECT INFORMATION, DRAWING INDEX ARCHITECTURE I INTERIOR DESIGN A AIR HANDLING UNIT ALT LT ALTERNATE REPLACE ALL FLOORING AND BASEBOARD, NEW FIRST FLOOR KITCHEN LAYOUT AND ARCHITECTURAL zervasgroup.com ALUM ALUMINUM DESIGN TEAM FIXTURES, NEW SECOND FLOOR CABINETRY AND PLUMBING FIXTURES, REINSULATE 209 Prospect Street © BLDG SECTION AV AUDIO/VISUAL ALL EXTERIOR AND PARTY WALLS. NEW GWB WALL COVERINGS AND PAINT. A2.01 FLOOR PLANS Bellingham,WA 98225 ® A2.02 RCP AND SCHEDULES 380.734.4744 BLDG BUILDING CLG CEILING MECHANICAL AND ELECTRICAL UPDATES TO CODE COMPLIANT FIXTURES. A5.01 INTERIOR ELEVATIONS CLR CLEAR ARCHITECTS A8.01 INTERIOR DETAILS CMU CONCRETE MASONRY UNITahk ZERVAS 209 PROSPECT STREET ELECTRICAL 5 REGISTERED COL COLUMN CONC CONCRETE \ 360-73 -4744 WA 98225 A' WALL SECTION 3ga734 4744 E1.01 ELECTRICAL- NOTES, LEGEND&INDEX CONT CONTINUOUS E2.01 ELECTRICAL- FIRST FLOOR PLANS �� CPT CARPET ® ELECTRICAL E2.02 ELECTRICAL-SECOND FLOOR PLANS \�_ CT CERAMIC TILE K ENGINEERS PROJECT DATA E6.01 ELECTRICAL-RISER DIAGRAM, PANEL SCHEDULE, LIGHT FIXTURE SCHEDULE , ' 0�win I NSO DIA DIAMETER 208 3RD ST OTON DIM(S) DIMENSION(S) X LYDEN, WA 98264 DN DOWN S DR DOOR X / AX.XX X INTERIOR ELEVATION SITE: DS DOWNSPOUT V ZONE R-3 DTL DETAIL X DWG DRAWING SITE ADDRESS: 508 6th Street#6,Anacortes WA 98221 DWR DRAWER AND (E) EXISTING 508 6th Street#5,Anacortes WA 98221 EA EACH ©© DOOR TAG ELEC ELECTRICAL ELEV ELEVATOR OR ELEVATION ROOM NAME ENL ENLARGED # ROOM NAME/NUMBER EQU EQUAL EXIST EXISTING EXT EXTERIOR (F) FUTURE - ELEVATION DATUM F-C FIBER CEMENT FCP FIBER CEMENT PANEL FD FLOOR DRAIN FE FIRE EXTINGUISHER — O COLUMN GRID FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FF SAM FOIL FACED SELF-ADHERED MEMBRANE FLR FLOOR FRT FIRE RETARDANT TREATED I WALL TAG FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR GA GUAGE GALV GALVANIZED GLB GLUE LAMINATED BEAM GWB GYPSUM WALL BOARD O WINDOW TAG HB HOSE BIB HR HOUR INSUL INSULATION HC HOLLOW CORE HM HOLLOW METAL HT SAM HIGH TEMP RESISTANT SELF-ADHERED MEMBRANE REVISION INDICATOR HSS HOLLOW STEEL SECTION ILO IN LIEU OF LF LINEAL FEET e INT INTERIOR REVISION NUMBER MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTL METAL i l • (N) NEW NA NOT APPLICABLE NFVA NET FREE VENT AREA -, NIC NOT IN CONTRACT • -a-t .,, OC ON CENTER '- . OD OUTSIDE DIAMETER �� z. , y,, ,.'� i,._ e OPP OPPOSITE -� '� _ - OH OPPOSITE HAND i E rf . '�.mr e �, u .s ORWL OVERFLOW RAIN WATER LEADER �. . i, ' " PLYWD PLYWOOD - `' e PNT PAINT OR PAINTED )'a. ,.,.s t. -- .` '> ht ' .r - PT PRESSURE TREATED REF REFERENCE OR REFRIGERATOR ; 5TH STREET REQD REQUIRED .an RCP REFLECTED CEILING PLAN REQ REQUIRED ? `I R&S ROD AND SHELF x =.5 RD ROOF DRAIN RO ROUGH OPENING - � RM ROOM . -{ RWL RAIN WATER LEADER _ +" a ' ' SC SOLID CORE SF SQUARE FOOT/FEET 6TH a REET Iel6TH STRE - PERMIT SET SHWR SHOWER ",*` SHT SHEET . SI SQUARE INCH(ES) ;' 4 + ' SIM SIMILAR _ r SPEC SPECIFIED OR SPECIFICATION *"A :' SQU SQUARE REV ISSUED FOR DATE SS STAINLESS STEEL r STL STEAL ST STREET ♦ _ STRUCT STRUCTURAL - • T TREAD „ - ._ - TPD TOILET PAPER DISPENSER TO TOP OF TOC TOP OF CONCRETE VICINITY MAP TOS TOP OF STEEL it PROJECT LOCATION TYP TYPICAL N.T.S. UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD VT VINYL TILE W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD ANACORTES WF WIDE FLANGE WRB WEATHER RESISTIVE BARRIER HOUSING WWF WELDED WIRE FABRIC AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY PROJECT INFO. DRAWING INDEX VICINITY MAP PROJECT No: 201711.05 DRAWN BY: ZN CHECKED BY: SCR DATE ISSUED: 04/01/19 G0.01 2014 /7/ m \I \ N V\ \\ tZERVAS I k © t� m q- ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 1 APR 04 2019 209 Prospect Street Bellingham,WA 98225 I�/ 360.734.4744 CITY OF ANACORTFC 6455 REGISTERED A ON C. BINSO STATE OF WASHINGTON CITY OF ANACORTES PLANNING & BUILDING DEPT: APPROVED PLANS PERMIT k: Ni24 L ADDRESS. Sob SO APPROVED BY: - SUBJECT TO FIELD INSPECTION. A PROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. FILE COPY ANACORTES HOUSING AUTHORITY INTERIOR UNIT RENOVATION 508 6th ST # 5 508 6th ST # 6 PERMIT SET ANACORTES , WA 98221 REV ISSUED FOR DATE PERMIT SET 04 . 01 . 2019 ,. ANACORTES HOUSING AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY PROJECT INFO. DRAWING INDEX VICINITY MAP PROJECT No: 201711.05 DRAWN BY: ZN CHECKED BY: SCR DATE ISSUED: 04/01/19 G0.00 c 2014 1 1 --1 /2' /". ; k1, LINES OF ADJACENT NIT e \ ,1 1 DEMOLITION NOTESDIMENSIONS FOR ADJA ENT UNIT, TYP --___________ _ 1. REMOVE ALL WALL AND CEILING PLASTER, GWB THROUGHOUT. I =—_ A. LINES OF ADJACENT UNIT _3 4 —I 1 2. REMOVE INSULATION IN ALL EXTERIOR AND PARTY WALLS. ARCHITECTURE I INTERIOR DESIGN MIRROR PLAN AND DIMENSIONS zervasgroup.com 3. REMOVE FLOORING THROUGHOUT UNITS, PRESERVE SUBFLOOR WHERE 209 Rroapeci StreetFOR ADJACENT UNIT,TYP. Bellingham,WA 98225 POSSIBLE AND REPLACE WHERE NECESSARY. REMOVE ALL BASEBOARD. 3e0.734.4744 4. REMOVE ALL INTERIOR SWINGING AND CLOSET DOORS, FRAME, HARDWARE. DOORS AND HARDWARE TO BE RE-USED AT OWNERS DISCRETION. "1 5 REGISTERED 5. REMOVE ALL INTERIOR DOOR AND WINDOW TRIM. A r 6. REMOVE ALL KITCHEN AND BATHROOM CASEWORK,APPLIANCES,AND �` PLUMBING. CONFIRM SALVAGE OF ITEMS WITH OWNER. 44 ei \�' n •ON C. ' •BINSO 7. SELECTIVE DEMOLITION AS NEEDED FOR PROJECT SCOPE. STATE OF WASHINGTON 8. SHORE UP SECOND FLOOR JOISTS FOR REMOVAL OF FIRST FLOOR EXISTING SOFFIT FRAMING WALLS. TO REMAIN 27'-7"V.I.F. DEMO EXISTING KITCHEN 31-0" PLAN LEGEND / EXISTING EXTERIOR PATIO CASEWORK AND WALLS. TO REMAIN 1 1 /GENERAL NOTES I O o - I -- DEMOLITION ITEM � ).. I 1 '- ---- - --� o O 1.ALL INTERIOR WALLS ARE UNRATED(ASSEMBLY BELOW)U.N.O. H ini = KITCHEN1. =�==J 1:0 , 101 A 5/8" GWB 1(EXISTING)WOOD STUDS I1 I LAZY SUSAN CORNER ® B 3 1/2"SOUND BATT i Ii • — CABINET S 5/8" GWB — I II i A / A5.03 C ( D DINING10 LIVING IU 2. MATCH ALL EXISTING LEVELS OF FIRE PROTECTION, INCLUDING INTERIOR LL-i-J �iL---iJ r A 103 WALLS, PARTY WALLS, SOFFITS, CAVITIES,AND DRAFT STOPS. — — c 3 3. USE 1/2"CEMENTITIOUS BACKERBOARD IN LIEU OF GWB AT TUBS/TUB OPEN UNDER COUNTER ENCLOSURES. FOR SEATING,THIS AREA 4. SEE INTERIOR ELEVATIONS FOR ADDITIONAL WALL FINISHES. 5. PROVIDE 1 HR FIRE SEPARATION PER CODE AND CITY REGULATIONS AT �� ~ MP w = ALL PARTY WALLS AND CEILINGS BETWEEN DWELLING UNITS. EQ EQ 6. HANG,TAPE,TEXTURE NEW GWB (SEE SPEC). — W / D — / - MECHANICAL PLAM SHELF, INCLUDE ROD W/ D 104 7. REINSULATE EXTERIOR AND PARTY WALLS BETWEEN DWELLING UNITS. c � F v F 13 INCLUDE SOUND BATT INSULATION IN PARTY WALL. < A b* EXISTING STAIR TO REMAIN, EXISTING MECHANICAL CLOSET FRAMING TO REMAIN APPLY NEW FLOORING EXISTING WASHER/DRYER TO REMAIN REMOVE ALL EXISTING SLIDING DOORS NEW UNIT PANEL, REPLACE EXISTING (SEE ELECTRICAL). INCLUDE NON-COMBUSTABLE PLYWOOD BACKING \ EXISTING FURNACE TO REMAIN r ) FIRST FLOOR PLAN - EXISTING / DEMO O FIRST FLOOR PLAN - PROPOSED / FINISH PLAN N. SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" 1 -1 F H 7 LINES OF ADJACENT UNIT MIRROR PLAN AND DIMENSIONS - FOR ADJACENT UNIT, TYP. 1 E J , ii L LINES OF ADJACENT UNIT MIRROR PLAN AND DIMENSIONS FOR ADJACENT UNIT,TYP. Fri— i-li t — - `i PERMIT SET DEMO AND REMOVE ALL EXISTING / —Iirl PLUMBING FIXTURES IN BATHROOM 204 28'-772"V.I.F. II II REV ISSUED FOR DATE 1-1 ,` 1 11 O I B r AlA / A5.03 � C O1 ^ j et."- � PLAN NORTH TRUE NORTH L- N I BEDROOM r---- BATHROOM 202 SCALE: 1/4"=1'-0" mililiiiiiiiimil `X) 204 0 4' A S y�'��� 0 ; • BEDROOM A�; � t;, n201ON p� o OUSINGANACORTES _ �v HOUSING FL AUTHORITY 4� `oL 4o4 1A HALLWAYL ry* '�;a y�,t _ ; 1 205 c 0 n SITE 1 / en I, f- --- I M I _ P ANACORTES HOUSING WHO 4,, — WH AUTHORITY a 1 \_!) �r � t BEDROOM H o I 203 FLOOR PLANS PROJECT No: 201711.05 DRAWN BY: ZN \\\ CHECKED BY: SCR REMOVE EXISTING WATER HEATER PLAM SHELF, INCLUDE ROD IN ALL BEDROOM CLOSETS DATE ISSUED: 04/01/19 REMOVE ALL EXISTING INTERIOR DOORS REPLACE WATER HEATER WITH GAS TANKLESS HEATER A2 .01 C--- SECOND FLOOR PLAN - EXISTING / DEMO C / SECOND FLOOR PLAN - PROPOSED / FINISH PLAN 2 2014 SCALE: 1/4"=1'-0" \ SCALE: 1/4"=1'-0" FINISH KEY 11 \\f\ \ \ i�;l SYMBL. CODE ITEM DESCRIPTION REMARKS RCP NOTES RFS-1 RESILIENT FLOORING SHEET MANUFACTURER: MANUFACTURER: MATERIAL: MATERIAL: A M COLOR: COLOR: IIUIII /!! N1.ARCHITECTURAL RCPS FOR DIMENSIONING OF CEILING FIXTURES ONLY. 4 L II SEE ELECTRICAL PLANS FOR SPECIFICATION AND LAYOUT. LINES OF ADJACENT UNIT J FINISH: FINISH: ARCHITECTURE INTERIOR DESIGN 2. MATCH ALL EXISTING LEVELS OF FIRE PROTECTION, INCLUDING INTERIOR MIRROR PLAN AND DIMENSIONS GAUGE: GAUGE: zervasgroup.com ,TYP. 209 Prospect Street FOR ADJACENT UNIT WALLS, PARTY WALLS, SOFFITS, CAVITIES,AND DRAFT STOPS. CONTACT INFO: CONTACT INFO: BeAingham,wA sa2zs 360.734A7M CENTERLINES 3. DIAGONAL DENOTES A FIXTURE CENTERED WITHIN A SPACE. MTL-1 METAL MANUFACTURER: MANUFACTURER: STAINLESS STEEL MATERIAL: MATERIAL: cr3--) COLOR: COLOR: 6455 REGISTERED FINISH: FINISH: GAUGE: GAUGE: �`,� EXTEND SOFFIT TO COVER CONTACT INFO: CONTACT INFO: ` 1, ' / ON C. ' 'BINSO REFRIGERATOR,ALIGN WITH O P-1 PAINT MANUFACTURER: MANUFACTURER: - STATE of yt�p�ON CLOSET DOOR COLOR: COLOR: 6 (0/ LINE OF EXISTING SOFFIT PL-1 PLASTIC LAMINATE MANUFACTURER: MANUFACTURER: - COU(JTER E GE EQ EO FRO WSTING SOFFIT AT DROPPED C� PATTERN/COLOR: PATTERN/COLOR: BEAM. REPLACE GB INSTALLATION TYPE: INSTALLATION TYPE: WID-1 WOOD MANUFACTURER: MANUFACTURER:i I 0 0I / 4110 PATTERN/COLOR: PATTERN/COLOR: cc w Li `t 1 I I ------ - j - - t - CUT CUT CEILING HT-MATCH \ 31 O w V INSTALLATION TYPE: INSTALLATION TYPE: EXISTING,TYP. U \ CEILING HT-MATCH 6: \ CONTACT INFO: CONTACT INFO: EXISTING,TYP. RB-1 RESILIENT BASE MANUFACTURER: MANUFACTURER: o - - I— ' O SERIES: SERIES: zZI _ I 4, I zCOLOR: COLOR: \ - \ - '° 5 CC-Da HEIGHT: HEIGHT: J CONFIGURATION: CONFIGURATION: - f ( ii C EQ EQ 0 = rr C) ROOMNAME NOTE: u'I ___,- — o A200 ©PP INSTALL RUBBER BASE AT BASE OF ALL CABINETS, TYP. CEILING HT-MATCH / c EXISTING,TYP. / K K IC SEE REFLECTED CEILING PLANS FOR CEILING FINISHES 1oH _ 1 1 -CORNER GUARDS NOT SHOWN ON INT ELEVATIONS FOR CLARITY k / \ ): ); rali / LINE OF BUILDING SECOND FLOOR SOFFIT ABOVE Q FIRST FLOOR PLAN - RCP SCALE: 1/4"=1'-0" DOOR SCHEDULE DOOR SYMBOL KEY: DOOR NUMBER ink DOOR m� HARDWARE \ I Z = v R. MARK f GROUP J U 1.ALL DOORS ARE 1 3/4"U.N.O. MATCH HEIGHT OF EXISTING DOORS, Z \ < to U Li Z a VERIFY 7'-O"IN FIELD BEFORE ORDER. Q 05 } 2. DOOR CONSTRUCTION: 00 co Z cc Q 1 j TYP=SOLID CORE FLUSH FACE WOOD r 1 di 1 CC uJ Y CA Zco HC= HOLLOW CORE L l�-�� 0 DOOR SIZE WxD a = p Q g re LV= LOUVERED WOOD LINES OF ADJACENT UNITix (1) (8) I- U LL CO LL li AL=ALUMINUM&GLASS 3.FACING AND FINISH: -11 t Fri— 1/ MIRROR PLAN AND DIMENSIONS TYP=HIGH PRESSURE DECORATIVE WOOD LAMINATE FOR ADJACENT UNIT, TYP. 1 3'a'xs-a"• A TYP TYP MP=METAL PAINTED PL= PLASTIC LAMINATE 2 6-0"Xs'-8" B LV TYP WD HP= HARDBOARD LAMINATE AL=ALUMINUM CLEAR ANODIZED 3 5'-0'x6'-8"• A TYP TYP WD 4. GLASS LS= LAMINATED SAFETY TI =TEMPERED INSULATED 4 2'-6'x6'-e"' C TYP TYP 5. 1/3, 1, 1.5, ETC. INDICATES HOUR OF FIRE RATING J 7.FRAME DOOR P: SEEDRAWING PERMIT SET 5 3'-0"X6'-8"• C - TYP TYP - - WD 7. FRAME TYPE: HM= HOLLOW METAL(SEE DRAWING) 6 2'-0'x6'-8"• C - TYP TYP - - WD WD= WOOD FRAME AND TRIM (SEE DRAWING) AS =ALUMINUM STOREFRONT, SEE A3.01 28'-4/2'V.I.F. 8. *DOOR SIZE TO MATCH EXISTING. CONTRACTOR TO CONFIRM IN i r 7 1'-e'x6'-8"' C - TYP TYP - - WD FIELD BEFORE ORDERING. REV ISSUED FOR DATE n / —N • I , CEILING HT-MATCH \ EXISTING,TYP. \ _ _ _ _ I \ w � �VJ CT 41E* N / v _ \v la, /' / / N N \ ( c) N J Y \ �Z \• w ANACORTES N > DOOR D R HOUSING \' I I� I I _ o I CC AUTHORITY \ �- a o o SITE 1 a / \ /' II II J — 1 I I _ / ANACORTES HOUSING -�-_ v / O I - AUTHORITY / RCP AND — — \, - \ CI SCHEDULES 1 \ X Z.' PROJECT No: 201711.05 LOUVRED PANEL DOORS DRAWN BY: ZN A B TO MECHANICAL RM C CHECKED BY: SCR DATE ISSUED: 04/01/19 SECOND FLOOR - RCP DOOR TYPES A2 ■02 c5i) SCALE: 1/4"=1'-0" (j"dNTEPJOR SCALE: 1/2"=1'-0" ©2014 I 7/ \\ \ \ / ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 380.734.4744 OPEN SHELVING FROM UPPER `64..55 REGISTERED A: CABINET TO CORNER. 4a LAMINATE COUNTERTOP AND .. 1' A a 'ON C. ' •BINSO BACKSPLASH. STATE OF WASNMOTON NEW SOFFIT ABOVE CABINETS ONLY, ALIGN WITH EXISTING SOFFIT. NEW SOFFIT ABOVE 6" NEW EXTENSION OF SOFFIT CABINETS ONLY, ALIGN WITH ezip EXISTING SOFFIT. En c') / 1 -0 ,, 1 i EXISTING SOFFIT STRUCTURE A f 1 _ . , x \ q . „ ,,. . . , „ „ , , , , , N , _ ,. _. N, N .., < > /' \ D I , (��� 77 CP N `\CD ) r (, -'/ i (. ,' ,' i 'r;"-- \ N CE , I (.0 co ., -_ , A8.01 I —r 1'-6" ,\ r / �''� 0_ Q C'J C'J L. ` -' 7/ 00 00 W W I IN 0 AN ) 9 \ \ 0 T �/ \ \ p �, �, si , io o �,' �� J__ i , u , v- — �. r . / v - r ,'' �� / - ' , i \l N`� fh W b o �/ iM `. a en i en / , ,' I e , I OS W V i i .v I . I �r �- A \ C F) r rF� 'vt 1" 2'-0" 1'-0" 2'-6" 1, 6n 2'-72' 1 r_6" 1 r-6" 1 r err 1 r_9rr STAIR FRONT DOOR >r DISH- r / / OVEN / / REF / / / / PANTRY/ LIVING ROOM WASHER BACKSPLASH GLUED. iN J LANDING TOP OF STOVETOP TO a UNDERSIDE OF HOOD. 0/�� ®KITCHEN ELEVATIONS KITCHEN ELEVATIONS " ' / SCALE: 1/2"=1'-0" o J SCALE: 1/2"=1'-0" I OPEN UNDER COUNTERTOP FOR SEATING PROVIDE TOWEL BAR SEE SPEC FOR MEDICINE CABINET L I L rJ PROVIDE TOILET slID PROVIDE ROD AND T SET / SIDE PANEL TO SUPPORT CURTAIN PAPER HOLDER. LAMINATE COUNTERTOP PERMIT COUNTERTOP D AND BACKSPLASH D ■ 0 REV ISSUED FOR DATE (F) ' (F) I O k / 0 — PAPER HOLDER. PROVIDE TOILET ile\ 1 2�" 12, 2-7 MIN/ (BEYOND SIDE PANEL) A8.01 OPEN UNDER COUNTERTOP 4 2'-1" X1'�" 2'-8" a = FOR SEATING I e / �+ rN SIN �� c o �l� 0 �� r L.,„ SCALE: 1/2"=1'-0" �ta'%��- 2 a I I �,N I ° II ANACORTES 71 � ���� W b CD) M �� :cam :-�� ie Dco HOUSING c� If siIIIi, AUTHORITY N W 1 CF \- (F ) _ - SITE 1 —�/ (F) I \ \ \ EQ EQ / v �, 1'-6" 1'-6" 1'-6" le 1'-Orr SEE SPEC FOR TUB 3.0' ANACORTES HOUSING 3 g„ 2 ENCLOSURE / AUTHORITY \ 4 4'-72' \ 4 3'-0" INTERIOR ELEVATIONS (FACING KITCHEN / BATHROOM REFRIGERATOR) 1 BATHROOM ELEVATIONSCD2 BATHROOM ELEVATIONS PROJECT No: 201711. BATHROOM ELEVATIONS BATHROOM ELEVATIONS DRAWN BY: 2005 ZN KITCHEN ISLAND ELEVATIONS A B SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" CHECKED BY: SCR C SCALE: 1/2'=1'-0" C SCALE: 1/2"=1'-0" DATE ISSUED: 04/01/19 A5.01 0 2014 SEE WALL TYPE CENTER PULLS IN 6"TALLNe If = so I TOP DRAWERS, TYPICAL \ NI INTERIOR1101 EXTERIOR I 5/8"GVVB. (TYP) ARCHITECTURE I INTERIOR DESIGN zervasgroup.com PT. 5/8"GWB. (TYP) zo9 Pmspea street BeBirgham,WA 98225 PER ELEV. 1" FINISH AS rt FINISH AS aso 7 47�t' I SCHEDULED SCHEDULED /7/' \ 1 . / . IC 41; -- o 4" RUBBER BASE 4"RUBBER BASE1 (V N � EXTERIOR WINDOW FLOOR FINISH PER 64s5 REGISTERED `� TRIM TO REMAIN SCHEDULE SEE SPEC FOR i— ` I� ` ��i � HARDWARE SELECTIONtwat , �!'� / bilk �� SIy'�f m� „ VARIES PER LOCATION 1 ►t\ ` 1/4" Oil EMAING WINDOW TO SEXIST NGR s •ON C.OF W• •WNW r011 1/4" i'sIII '/ LINE OF FULL HT —LINE OF FULL HT : SIDE CASING BEYONDiii MJAM I SIDE CASING BEYOND HEAD AN SIDE CIASING 1 1/2"DOOR ON AS I NEEDED TO MEET NEW 2 TYP DOOR HEAD TRIM DETAIL TYP WINDOW HEAD TRIM DETAIL RUBBER BASE @ FLOORING, VARIOUS TYP CABINET HARDWARE MOUNTING LOCATION 0SCALE:3"=1'-0" \, O SCALE: 3"=1'-0" SCALE 3"=1'-0" �) SCALE3"=1'-0" LINE OF FULL HT I Ili iv SIDE CASING BEYOND, WHERE FLOOR SURFACE IS TERMINATE INTO STOOL EXTERIOR WINDOW NOT CONTINUOUS, RUN INCLUDE WINDOW TRIM TO REMAIN FLOOR SURFACES TO BLINDS,TYPICAL EXISTING WINDOW TO CENTER OF DOOR, INSTALL REMAIN SchluterSCHIENETRANSITION 1l2" ��:��-kin �� STRIP @ TRANSITIONS. g ♦' NO THRESHOLD REQD. bi WHERE FLOOR SURFACE IS ��� J���,�� r!' CONTINUOUS @ BOTH SIDES \ ���` OF DOOR. �\ RABBETED PLAM WINDOW STOOL •IIi /`,isomalimi \ },�.._.... ._ .. ;... .. _ INTERIOR " EXTERIOR ALIGN TOP OF CABINET 5 WITH EXISTING 7'-0" SOFFIT / 1, 0„ Y �\ 7 7.--: LINE OF EXISTING SOFFIT BEYOND TYP DOOR THRESHOLD DETAIL TYP WINDOW STOOL DETAIL © SCALE: 3„_1,_0„ SCALE: 3„_t,_0„ PLAM ADJUSTABLE SHELF SIDE CASING LINE OF WINDOW SILL 1/4" • BEYOND 3 1/2" 1/2" SIM N I . I io 131/2" :Is I . • N JAM EXTENION AS NEEDED TO MEET NEW � INTERIOR SURFACES "l�"a HEAD AND SIDE CASING �IM sag 7 • \\ illit / PULL HARDWARE /� . ipiiid A , �w_\ I MEDICINE CABINET, — I SEE SPEC, MOUNT PER 'I'f:I �s �• MANUFACTURERS ss- 1/2 ��f��� EXISTING WINDOW TO �b r,' RECOMMENDATIONS 3/4" REMAIN !� LINE OF BASEBOARD SET EXTERIOR WINDOW 2'-1" / PERMIT BEYOND TRIM TO REMAIN _• LAMINATE COUNTER • LAMINATE COUNTER 2'-1" OVER SUBSTRATE OVER SUBSTRATE Ig DRAWER le iv CV REV ISSUED FOR DATE TYP DOOR SIDE CASING TRIM DETAIL TYP WINDOW SIDE CASING TRIM DETAIL Ni. ;:, ; / © SCALE: 3„=1, 0„ SCALE: 3"=1'-0" I ��/.�iiD %/iiiiiiiilQ ��JJ ZSI I io JI io 1 t 9 ANGLE IRON AS REQ. IIII N STATIONARY PANEL SCALE: AS NOTED �— v v �, OP I J = o 11 J = ANACORTES \ c� PLAM Y) FLAT HEADCASING FLAT HEADCASING1 . ADJUSTAB E o • ADJUSTABLE • o HOUSING TERMINATE SIDECASING TERMINATE SIDECASING INTO •.. SHELF X2,TYP. M SHELF XL,TYP. N INTO UNDERSIDE OF 1/4" UNDERSIDE OF HEADCASING 1/4„ AUTHORITY HEADCASING I I I I SITE 1 PLAM ON ALL PLAM ON ALL TERMINATE SIDECASING INTO STOOL 1/2" / INTERIOR SURFACES . / INTERIOR ANACORTES HOUSING f/ SURFACES AUTHORITY PLAM WINDOW STOOL v FLAT SIDECASING / , X TERMINATE BASEBOARD BUILDING DETAILS \ } INTO SIDECASING J 3„ PROJECT No: 201711.05 PLAM BASE TO ,1. 3" / PLAM BASE TO / DRAWN BY: ZN MATCH CABINET MATCH CABINET CHECKED BY: SCR DATE ISSUED: 04/01/19 TYP BASE & DOOR TRIM DETAIL ELEVATION 8 SCALE: 3 -t-0 TYP SCALE: 3WINDOW TRIM DETAIL ELEVATION 11 BATHROOM CASEWORK SECTION 12 KITCHEN CASEWORK SECTION SCALE: 1 1/2"=11-0" SCALE: 1 1/2"=1'-0" A8.0 1� 4 ©2014 I j I /�NOTES (APPLICABLE TO ALL ELECTRICAL DRAWINGS): ELECTRICAL LEGEND ARCHITECTURE I INTERIOR DESIGN 1. ALL SYSTEMS, EQUIPMENT, DEVICES, RACEWAYS, CABLES, ETC. INDICATED ARE zervasgroup.com NEW UNLESS SPECIFICALLY NOTED AS EXISTING. 209 Prospect S eet LIGHTING OUTLETS MISCELLANEOUS Bellingham,WA 98225 380.734.4744 2. THE ELECTRICAL WORK SHALL INCLUDE ALL WORK SHOWN ON THE DRAWINGS, DETAILS, DIAGRAMS, SCHEDULES, ETC., AND AS DESCRIBED IN THE SPECIFICATIONS. I I LUMINAIRE,SURFACE MID. Cc DUPLEX OUTLET / xt BRANCH CIRCUIT,ABOVE GRADE,CONCEALED(OR SIMILAR K ENGINEERS INC. SLASHES =NO.OF CIRCUIT CONDUCTORS WHERE APPLICABLE 3. PLAN DRAWINGS ARE DIAGRAMMATIC IN FORM AND DO NOT ATTEMPT TO SHOW C= LUMINAIRE,PENDANT MID. t DOUBLE DUPLEX OUTLET CIRCUITS ARE 2 CONDUCTOR UNLESS.NOTED OTHERLEE, 208 Third Street COMPLETE DETAILS OR LIST EVERY ITEM OF THE ELECTRICAL SYSTEM, EQUIPMENT, 4 +14 AWs FOR 15A CIRCUITS 4+12 FOR 20A CIRCUITS) Lyndon, WA. 98264 OR BUILDING CONSTRUCTION; HOWEVER, THE ROUTING OF RACEWAYS AND CIRCUITS, it LUMINAIRE,WALL MID. �GF DUPLEX OUTLET,GROUND FAULT INTERRUPTING FBus.AX �360� 354-6794 354-4757 BRANCH CIRCUIT,ABOVE GRADE,EXPOSED THE LOCATIONS OF EQUIPMENT, DEVICES AND FIXTURES REPRESENT THE DESIRED I I STRIP LUMINAIRE eft DUPLEX OUTLET,WEATHERPROOF FINISHED ARRANGEMENT. / -t HOMERN TO LOCATION NDICATED,CONCEALED(TYPICAL) 0 RECESSED DOILNLIGHT • SPECIAL PURPOSE OUTLET 4. RACEWAYS AND CABLES THROUGHOUT THE FACILITY SHALL BE RUN CONCEALED IN HOMEfdN TO LOCATION INDICATED,EXPOSED(TYPICAL) R. D THE WALLS, ABOVE THE CEILING OR BELOW THE FLOOR WHERE POSSIBLE, EXCEPT, I-3 LUMINAIRE,WALL MID 0 SPECIAL PURPOSE CONNECTION `P or WA r A EXPOSED WITHIN UTILITY & OTHER NON-PUBLIC SPACES. WITHIN PUBLIC SPACES, EXISTING CONDUIT,NEW CABLE v�w ����� WHERE DUE TO THE BUILDINGS CONSTRUCTION, IT IS NOT POSSIBLE TO ROUTE LUMINAIRE,CEILING MTD d IDIT TELECOMMUNICATIONS OUTLET,FLUSH MOUNTED 3~m 1t 1 N RACEWAYS & CABLES CONCEALED, RACEWAYS MAY BE RUN EXPOSED. EXPOSED (IDIT = I GATe t I COAX CABLE, TYPICAL) — — BELOW GRADE GCXNDUIT , ( �' ' �\g RACEWAYS SHALL BE RUN AS NEATLY & UNOBTRUSIVELY AS POSSIBLE, SUPPORTED __ __ &. µ794 \tilE AS REQUIRED, PARALLEL OR AT RIGHT ANGLES TO CEILINGS, WALLS & STRUCTURAL '� GROUND GABLE �'• 'A�Crsr�p ti t MEMBERS. ,tom ANCILLARIES -----,-, COMM CABLE (ROUTED OPEN WITHOUT RACEWAY) SIONAL '+ 5. RACEWAYS AND CABLES SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: SWITCI�ING GI FIRE ALARM SMOKE DETECTOR © JUNCTION BOX A. BRANCH CIRCUIT INTERIOR ACCESSIBLE CONCEALED SPACES- ROMEX (TYPE NM) 5 SINGLE-POLE SWITCH NO FIRE ALARM SMOKE DETECTOR,WALL MOUNTED DISCONNECT SWITCH 53 THREE-WAY SWITCH ❑a DOORBELL BUTTON ® PANELBOARD B. FEEDER INTERIOR ACCESSIBLE CONCEALED SPACES -EXISTING TYPE ELECTRICAL METALLIC TUBING (EMT)WITH NEW CABLE. IMER SWITCH SiT DOORBELL STROBE/CHIME EXHAUST FAN C. INTERIOR, EXPOSED IN ROOMS, CORRIDORS &THE LIKE WHERE READILY ® THERMOSTAT III DOORBELL POWER SUPPLY ® FAN/LIGHT COMBINATION VISIBLE TO BUILDING OCCUPANTS - SURFACE METAL RACEWAY (SMR). up WEATHER PROOF D. EXTERIOR ABOVE GRADE- GALVANIZED RIGID STEEL CONDUIT(GRS). DEMOLITION Ex EXISTING TO REMAIN E. EXTERIOR BELOW GRADE-POLYVINYL CHLORIDE CONDUIT(PVC). (Jr REx REPLACE EXISTING .7 REL RELOCATE EXISTING 6. RACEWAYS SHALL BE SIZED SO THAT THE CABLE FILL DOES NOT EXCEED 40%, ti--N, DEMOLISH EXISTING DEVICE, INCLUDING EXCEPT, MINIMUM CONDUIT SIZES SHALL BE NOTED ON THE DRAWINGS. 3-t ALL ASSOCIATED WIRING,BOXES,SUPPORTS, NT FUTURE ETC.,EXCEPT EXISTING BOXES MAY REMAIN 7. DEVICE BOX SIZES SHALL BE SIZED IN ACCORDANCE WITH NEC FOR BOX FILL, AND IF THEY ARE SUITABLE FOR THE NEW SHALL BE SUITABLE FOR USE WITHCF} THE WIRING METHODS USED. INSTALLATION 8. DEVICE MOUNTING HEIGHTS SHALL BE AS FOLLOWS, UNLESS SPECIFICALLY NOTED © OTHERWISE. MOUNTING HEIGHTS SHOWN ON THE DRAWINGS ARE TO THE CENTER OF THE BACK BOX FROM THE INTERIOR FINISHED FLOOR. A. POWER, TELECOMMUNICATIONS, AUDIONIDEO, ETC. RECEPTACLES - 18" B. LIGHTING SWITCHES, CONTROL STATIONS, ETC. -44" C. DEVICES ABOVE COUNTERS-4" ABOVE BACKSPLASH. 9. TELECOMMUNICATIONS CONDUITS SHALL BE PROVIDED WITH PULL ROPES BELOW GRADE AND PULL STRINGS ABOVE GRADE. EXISTING CONDUITS TO BE USED SHALL BE FISHED AND CLEANED PRIOR TO INSTALLATION OF CABLES. 10. BRANCH CIRCUIT CABLES, EQUIPMENT GROUND CABLES AND ABOVE GRADE FEEDER CABLES SHALL BE 2/C COPPER, #12 AWG UNLESS NOTED OTHERWISE, WITH 600V TYPE NM CABLE . 11. PROTECT"OPEN" CABLE WIRING FROM ROUGH AND/OR SHARP EDGES ON SUPPORTS, STRUCTURAL MEMBERS, ETC. AS REQUIRED DURING INSTALLATION. 12. LABELING & NAMEPLATES: A. OUTLETS SHALL BE LABELED WITH THE PANEL AND CIRCUIT NUMBER FROM WHICH ITS FED. LABELS SHALL BE HEAVY DUTY ADHESIVE TYPE, CLEAR TAPE WITH BLACK LETTERING, MADE WITH A LABEL PRINTING DEVICE. B. JUNCTION BOXES SHALL BE LABELED WITH THE PANEL AND CIRCUIT NUMBER CONTAINED WITHIN. MARKING SHALL BE LEGIBLY HAND-WRITTEN WITH BLACK INDELIBLE MARKER. C. PANELBOARDS AND FEEDER BREAKERS SHALL BE PROVIDED WITH PHENOLIC NAMEPLATES, BLACK FACE, WHITE CORE, ENGRAVED WITH 1/8" LETTERS. —' D. SWITCHBOARDS AND PANELBOARDS SHALL BE PROVIDED WITH PHENOLIC SET NAMEPLATES TO IDENTIFY THE SYSTEM COLOR CODING SCHEME FOR PHASE AND NEUTRAL CONDUCTORS. REV ISSUED FOR DATE E. SWITCHBOARDS AND PANELBOARDS SHALL BE PROVIDED WITH LABELS TO WARN PERSONNEL OF POTENTIAL ARC FLASH AND SHOCK HAZARDS. PLAN NORTH TRUE NORTH SCALE: NONE r= 0 X' ANACORTES HOUSING DRAWING INDEX AUTHORITY SITE 1 SHEET DRAWING TITLE ANACORTES HOUSING E 1.01 ELECTRICAL-NOTES, LEGEND& INDEX E2.01 ELECTRICAL- FIRST FLOOR PLANS AUTHORITY E2.02 ELECTRICAL- SECOND FLOOR PLANS ELECTRICAL U E6.01 ELECTRICAL-POWER SYSTEM RISER DIAGRAM, PANEL& LIGHTING FIXTURE SCHEDULES NOTES[]LEGEND[]INDEX PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 E1 .01 ©2010 j ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 360.734.4744 K ENGINEERS INC. 208 Third Street Lyndon, WA. 98264 Bus. (360) 354-4757 FAX (360 354-6794 R. D v\,P aF wAs r A� dJ ,II ., N IF I . U\) �r`r 44794 ,ggva • el'�, 'tCISTE�"' 1 SSIONAL 11 r_MULTI-METER PACK (REPLACE EXISTING) FURIACE PRIER WASFIER �� li � PRYER WASHER 1_ inl • calm PULL 50X •Ale ' /i = 1: n 6ri i �� 2 EXISTING AUGEMT (EACH WITH ) • /10 • _,F' ILA! I NEW 3 •I G ALUM + I •6 ALUM GND) p t.4-, I Yr G • a .4 16 COMM PANEL 11 ROUTED THROUGH r-C K F _��� �' a M L I—i J — comm PANEL �I 6 CRAWLSPACEJ f" , - IN arlir PANEL ii EXISTING .18 •:1111111 A‘ t# ii 2 PANEL / % 3 ` A I— , im is 1 k"3= I iI II II n GFap li- Ia 33' .:.� • in •33' _ `� • �' LIVING _�'r 1 kI IJ — DISHWASHER �� 41 C 5 9 II DI I G I =4 pISPOSAL AR rr- -�' ` (I Mri JI HEN C „ PANEL 1 F-,--� Ye I ‘ • ,zl RANG —44, �I " I _`-44' T a-GPI " _ � " IDIT 6 we l c urip Ae A* I taw : I �p 3 �i. I,b 9� �L I ' 6 .w .w �_-�--_.�ti, 9,11 6 a1MMLH 9,II 6 •rrl `"a �}i�; , .,. v'"v $ JPPrI �U ' III If 7- MllIllkt giniw-- fro 6, f y.,( 'L___J �= )-t Ir 1II — I I HEN • PANEL 'I I—__='T Or DISPOSAL '11 E ..•_•, ) • :J�:_ Iiiiiibl f i _€' DIBHWA8fER I 1 911 I I _€� F� �1� le C 5 , i DINING jup .33' LIVING r " u ♦ -€ GFI -x_ II 14re s A 3 -REMOVE EXISTING ` I\ I .03 I� •4111 • IP PANEL - 1uil nefraI \ .:hhi--ccrim-1- 11-10 vr v. i .1 ..... ( CJ1 ) rC ;Frr%, rt' WIT ilL_ 2 MM6•,� Kr) Gjr/L _ M EXI= MGJ SET . 21, 11 •C .©. IDIT, l� �,� 'cc ,'I'ti !� 'I' �i6 REV ISSUED FOR DATE w FURNACE- PRYER WASHER -12RlEE PLAN NORTH TRUE NORTH SCALE: 1/4"=1'-0" 0 4' ELECTRICAL - FIRST FLOOR POWER PLAN - DEMOLITION 0 ELECTRICAL - FIRST FLOOR POWER PLAN - PROPOSED ® SCALE: 1/4"=,-0" SCALE: 1/4"=1'-0" ANACORTES HOUSING AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY ELECTRICAL p FIRST FLOOR PLANS PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 E2.01 ©2019 ii,//////// ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 360.734.4744 K ENGINEERS INC. 208 Third Street Lyndon, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 V- tJF WA /r� .A vA asiv 1 ^o.'x S ,�p 44794 �'I ir SIONAL 1'r_ 14 v A — ` . _ \ , s-- C8 1, \ kigezK_} g - \ /T � I .. C5, comm PANEL ilif `• to * I, -. \y D II T 8 ,ii_ i IT 1 �COMM PANEL �� ti7fte nI . aip ,g) 1 / =l8 \\i ce \, 1DIT1, III r, � ( — A • — L L J ( Yi t, O) T-4. 4! elCC • A or. I \ / II 0 II \Hr----"T 2 O -i��,� r-t taw Vv� 8 I ,;, m 0LAR 'RI LA i O � 0= V 1-1" =fa 1,2 a K ; �. r ?i DI Ic____LA J / r,G "� /\\ �% \�, Gq'r1 PALL B �1=�-2b / _ I 'IDIT = IDIT Itirl- it _ C_S')Dr if s " 8 il. \\ IDIT t 1 \11 Acm I \ / �� CC IM PANEL Fib t =€� # H 1 �t . ‹ 6 ,, D2 SET o�� (Th * *-/ _- / ' c� / ' REV ISSUED FOR DATE Li 41) V., PLAN NORTH TRUE NORTH SCALE: 1/4"=1'-0" Olr ® ELECTRICAL - SECOND FLOOR POWER PLAN - DEMOLITION O ELECTRICAL - SECOND FLOOR POWER PLAN - PROPOSED ANACORTES SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" HOUSING AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY ELECTRICAL p SECOND FLOOR PLANS PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 E2 .02 0 2010 ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham.WA 98225 360.734.4744 K ENGINEERS INC. 208 Third Street Lyndon, WA. 98264 \ Bus. (360) 354-4757 FAX (360) 354-6794 MULTI-METER PACK (REPLACE EXISTING) EXTERIOR VOLTAGE: 120/240V,1 PH,3 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND TYPE: BOLT-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) MULTI-METER PACK FULL AC RATING: 22,000 A General Lighting&Outlets(3 W/SF) 12096.0 6048.0 18144.0 Ft Di ENCLOSURE: NEMA 3R SERIES AC RATING: NONE Small Appliance&Laundry 6000.0 3000.0 9000.0 ``Q' OF WA n A MOUNTING: SURFACE _ Electric Range 32000.0 16000.0 48000.0 .�w ���� A SPECIAL PROVISIONS: Electric Clothes Dryer 14000.0 10000.0 24000.0 ,�me l .►i BUSSING: MANUFACTURER'S STANDARD Misc.Fixed Appliances 9706.0 4853.0 14559.0 UNIT I UNIT 2 9 ( '-' ' ut CONTINUOUS RATING: 600 A MASTER&FEEDER NAMEPLATES TOTAL 73802.0 39901.0 113703.0 FULL AIC RATING: 22,000 A Demand Factor(First 10,000W) 1.00 10000.0 t • 4,4794��q' ' Demand Factor(Remainder) 0.40 41481.2 0-UNIT PANEL I PANEL 2 •. isle 41 SERIES AIC RATING: NONE GROUND BAR (REPLACE EXISTING) (REPLACE EXISTING) SSIONAL - Air Conditioning 0.0 0.0 0.0 1.00 0.0 MAIN: LUGS ONLY SUITABLE FOR USE AS SERVICE Electric Space Heating 0.0 0.0 0.0 1.00 0.0 UNIT 6 SIT 5 UNIT 4 UNIT 3 LOCATION: BOTTOM ENTRANCE EQUIPMENT 25%Largest Motor 166.8 TOTAL LOAD 147604.0 79802.0 227406.0 51648.0I I 0-UNIT TOTAL AMPS 615.0 332.5 947.5 215.2 EXISTING 114' EMT (NEW 3 •I CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER/BRANCH CIRCUIT CONN. EXISTING UNIT-; gXISTING UNIT-* gXISTNG UNIT-3" EXISTING UNIT--e g g I LOAD IVA) DESCRIPTION NOTE AMP/P NO (PHASE) NO AMP/P DESCRIPTION rare LOAD(VA)' PANEL 6 I AUG ALUM. I •6 AWG ALUM. DISTRIBUTION SECTION PANEL 5 PANEL 4 PANEL 3 g Q I I GNP) (TO REMAIN) (TO REMAIN) (TO REMAIN) (TO REMAIN) CONN. FEEDER/BRANCH CIRCUIT BKR I CKT BUS CKT I BKR I FEEDER/BRANCH CIRCUIT CONN. MLLTI-METER PACK-e g 9 LOAD(VA) DESCRIPTION NOTE AMP/P NO (PHASE) NO AMP/P DESCRIPTION "ore LOAD(VA) (REPLACE EXISTING. r 9495.0 UNIT PANEL-UNIT 1 (2) 100/2 MTR 1 A 2 MTR 100/2 UNIT PANEL-UNIT 2 (2) ' 9495.0 RE-CONNECT EXISTING 10431.5 , I , I I B I I I 10431.5 SERVICE a FEEDER -___�___ _...) 9417.0 UNIT PANEL-UNIT3 (1) 100/2 MTR 3 A 4 MTR 100/2 UNIT PANEL-UNIT4 (1) 9417.0 CONDUITS I CONDUCTORS 9009.5 I I . I B I I I 9009.5 PTO EXISTNCs WWATER PIPING (1) 100/2 MTR 5 A MTR 100/2 UNIT PANEL-UNITE (1) 9417.0 AS REQUIRED.) I 9417.0 UNIT PANEL-UNIT 5I -CONNECT EXISTING GROUNDING ELECTRODE CONDUCTOR 9009.5 I I I B I I 9009.5 '� '� �� � 1 y r. ¢_______-__y NOTES: 1 .6 MG GND (1) RECONNECT EXISTING FEEDER TO NEW CIRCUIT BREAKER. (2) NEW FEEDER TO REPLACE EXISTING. EXISTING 3' PVC (EXISTING 4 EXISTING 1174' EMT (EACH WITH 3 •I - SERVICE CONDUCTORS TO REMAIN.) AUKS ALUM. + I •4 AUKs ALUM.CND) / TO PUD PADMOUNT UNIT PANEL - UNIT 1 (REPLACE EXISTING) UNIT #1 TRANSFORMER S C VOLTAGE: 120/240V,1 PH,3 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND .4 GROUND RODS TYPE: LOADCENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) (SPACED e I0-0') ENCLOSURE: NEMA 1 FULL AIC RATING: 10,000 A General Lighting&Outlets(3 W/SF) 0.0 3024.0 3024.0 MOUNTING: FLUSH SERIES AC RATING: NONE Small Appliance&Laundry 0.0 1500.0 1500.0 III ELECTRICAL - POWER SYSTEM RISER DIAGRAM Electric Range 0.0 8000.0 8000.0 BUSSING: MANUFACTURER'S STANDARC SPECIAL PROVISIONS: Electric Clothes Dryer 0.0 5000.0 5000.0 NO SCALE CONTINUOUS RATING: 100 A Misc.Fixed Appliances 0.0 2426.5 2426.5 FULL AC RATING: 10,000 A MASTER NAMEPLATE TOTAL 0.0 19950.5 19950.5 SERIES AC RATING: NONE Demand Factor(First 10,000W) 1.00 10000.0 GROUND BAR Demand Factor(Remainder) 0.40 3980.2 MAIN: LUGS ONLY LOCATION: BOTTOM SQUARED TYPE HOM Air Conditioning 0.0 0.0 0.0 1.00 0.0 Electric Space Heating 0.0 0.0 0.0 0.40 0.0 25%Largest Motor 166.8 TOTAL LOAD 0.0 19950.5 19950.5 14147.0 TOTAL AMPS 0.0 83.1 83.1 58.9 CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER/BRANCH CIRCUIT CONN. LOAD(VA) DESCRIPTION NOTE AMP/P NO (PHASE) NO AMP/P DESCRIPTION NOTE LOAD(VA) 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 1 A 2 15/1 LTG-KITCHEN AFCI 0.0 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 3 B 4 15/1 OUTLET-BATHROOM GFCVAFCI 0.0 LIGHTING FIXTURE SCHEDULE 667.0 DISPOSAL GFCVAFCI 20/1 5 A 6 15/1 LTG&OUTLETS-LIVING ROOM AFCI 0.0 931.5 DISHWASHER GFCVAFCI 20/1 7 B 8 15/1 LTG&OUTLETS-UPSTAIRS NORTH AFCI 0.0 TYPE DESCRIPTION COLOR LUMENS VOLTS MANUFACTURER&CAT.NO. LOADS 4000.0 RANGE 50/2 9 A 10 15/1 LTG&OUTLETS-UPSTAIRS SOUTH AFCI 0.0 4000.0 I 11 B 12 15/1 LTG&OUTLETS-DOORBELL,LAUNDRY&COMM F AFCI 0.0 TEMP. (OR APPROVED EQUAL) WATTS VA 0.0 SPARE AFCI 15/1 13 A 14 20/1 FURNACE AFCI 828.0 -- - 0.0 SPARE AFCI 15/1 15 B 16 20/1 WASHER AFCI 1500.0 A CELNG SURFACE MOUNTED, 14"ROUND, 3000K 2000 120 ASL HDT-20-3000K-D14-DV-FSN 20 21 0.0 SPARE AFCI 20/1 17 A 18 30/2 DRYER 2500.0 BRUSHED NICKEL FINISH, POLYCARBONATE LENS NUVO 62-1036 0.0 SPARE AFCI 20/1 19 B 20 I 2500.0 0.0 SPACE 21 A 22 SPACE 0.0 0.0 SPACE 23 B 24 SPACE 0.0 B CEILING SURFACE MOUNTED, 10"ROUND, 3000K 1200 120 ASL HDT-123000K-D10-DV-FSN 12 13 MAIN LUGS BRUSHED NICKEL FINISH, POLYCARBONATE LENS NUVO 62-1035 UNIT PANEL - UNIT 2 (REPLACE EXISTING) UNIT #2 C CELING FLUSH MOUNT ROUND,7" ROUND, 3000K 820 120 SATCO NUVO S9331 14 14 VOLTAGE: 120/240V,1 PH,3 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND WHITE FINISH,DMMABLE. ASL SAS-7-WHITE-13.5-3000K-D7 TYPE: LOADCENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) ESSENTIAL SMT-3K7-14-900W ENCLOSURE: NEMA 1 FULL AIC RATING: 10,000 A General Lighting&Outlets(3 W/SF) 0.0 3024.0 3024.0 DALS CFLEDR06-WH MOUNTING: FLUSH SERIES AC RATING: NONE Small Appliance&Laundry 0.0 1500.0 1500.0 LIrON LCMPD7RWT30 Electric Range 0.0 8000.0 8000.0 ^I BUSSING: MANUFACTURER'S STANDARC SPECIAL PROVISIONS: Electric Clothes Dryer 0.0 5000.0 5000.0 D CELING RESIDENTIAL GRADE RECESSED HOUSING, 3000K 600 120 HALO E7SOICAT LT56 10 10 CONTINUOUS RATING: 100 A Misc.Fixed Appliances 0.0 2426.5 2426.5 6"ROUND, IC RATED,WITH INTEGRATED LED W-IWE FULL AIC RATING: 10,000 A MASTER NAMEPLATE TOTAL 0.0 19950.5 19950.5 BAFFLE TRIM. SET SERIES AC RATING: NONE Demand Factor(First 10,000W) 1.00 10000.0 GROUND BAR Demand Factor(Remainder) 0.40 3980.2 MAIN: LUGS ONLY LOCATION: BOTTOM SQUARED TYPE HOM Air Conditioning 0.0 0.0 0.0 1.00 0.0 E WALL SCONCE, 10"x 4.125"x 3.5", BRUSHED NICKEL 3000K 800 120 NUVO 62-317 10 10 REV ISSUED FOR DATE Electric Space Heating 0.0 0.0 0.0 0.40 0.0 FINISH WITH FROSTED ACRYLIC LENS. 25%Largest Motor 166.8 TOTAL LOAD 0.0 19950.5 19950.5 14147.0 TOTAL AMPS 0.0 83.1 83.1 58.9 F BATHROOM VANITY,24"LONG,BRUSHED NICKEL 3000K 2000 120 ASL VBJ-19-3000K-L22-DV-FSN 26 27 - FINISH& POLYCARBONATE LENS NUVO 62-872 CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER/BRANCH-CIRCUIT ' CONN. LOAD(VA) DESCRIPTION 'JTE AMP/P NO (PHASE) NO AMP/P DESCRIPTION "GTE LOAD(VA) 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 1 A 2 15/1 LTG-KITCHEN AFCI 0.0 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 3 B 4 15/1 OUTLET-BATHROOM GFCVAFCI 0.0 667.0 DISPOSAL GFCVAFCI 20/1 5 A 6 15/1 LTG&OUTLETS-LIVING ROOM AFCI 0.0 G EXTERIOR WALL MOUNT ENTRY LIGHT, 5000K 1800 120 NW065-096 20 20 931.5 DISHWASHER GFCVAFCI 20/1 7 B 8 15/1 LTG&OUTLETS-UPSTAIRS NORTH AFCI 0.0 5.5"H X 5"WX 9"D, POLYCARBONATE HOUSING PLAN NORTH TRUE NORTH 4000.0 RANGE 50/2 9 A 10 15/1 LTG&OUTLETS-UPSTAIRS SOUTH AFCI 0.0 BRONZE COLOR,WET LOCATION RATED. 4000.0 I 11 B 12 15/1 OUTLETS-DOORBELL&COMM PANEL AFCI 0.0 SCALE: 1/4"=1'-0" 0.0 SPARE AFCI 15/1 13 A 14 20/1 FURNACE AFCI 828.0 0 4' 0.0 SPARE AFCI 15/1 15 B 16 20/1 WASHER AFCI 1500.0 0.0 SPARE AFCI 20/1 17 A 18 30/2 DRYER 2500.0 H BREEZEWAY WALLPACK LIGHT,8.5"W x 7.5"H x 5000K 3300 120 NUVO 65-133(ADD PHOTOCELL) 27 27 ANACORTES 0.0 SPARE AFCI 20/1 19 B 20 I 2500.0 5"D, POLYCARBONAGE HOUSING, BRONZE COLOR 0.0 SPACE 21 A 22 SPACE 0.0 WET LOCATION RATED,WITH INTEGRAL PHOTOCELL. 0.0 SPACE 23 B 24 SPACE 0.0 MAIN LUGS HOUSING AUTHORITY NOTES: SITE 1 1. CONTRACTOR& LIGHTING FIXTURE SUPPLIER SHALL VERFY DESCRIPTION,MOUNTING REQUIREMENTS,CATALOG NUMBERS, ETC.MATCH.ADVISE ENGINEER OF ANYCONFLICTS OR DISCREPANCIES DURING BIDDING. ANACORTES HOUSING AUTHORITY ELECTRICAL p RISER DIAGRAM[PANEL SCH.° p LTG FIXTURE SCH. PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 Ea01 02010