Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-2019-0184 - Plans Permit Set - RESIDENTIAL INTERIOR ONLY REMODEL
/f/ ARCHITECTURE I INTERIOR DESIGN APR 04 2019 zervasgroup.com 209 Prospect Street Bellingham.WA 98225 CITY OF ANACORTES 360.734.4744 6455 REGISTERED A ON C. BINSO STATE OF WASNINGTON FILE COPY CITY OF ANACORTES PLANNING & BUILDING DEPT: APPROVED PLANS PERMIT #: PP OLiick ADDRESS: iV0 694 59 y APPROVED BY: ' y�J4, SUBJECT TO FIELD INSPECTION./APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. ANACORTES HOUSING AUTHORITY INTERIOR UNIT RENOVATION 508 6th ST # 5 508 6th ST # 6 PERMIT SET ANACORTES , WA 98221 REV ISSUEDFOR DATE PERMIT SET 04 . 01 . 2019 ANACORTES HOUSING AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY PROJECT INFO. DRAWING INDEX VICINITY MAP PROJECT No: 201711.05 DRAWN BY: ZN CHECKED BY: SCR DATE ISSUED: 04/01/19 G0.00 ©2014 / / N \V\ii ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS OWNER PROJECT DESCRIPTION DRAWING INDEX & AND 719 Q.AVEANACORTES HOUSING AUTHORITY INTERIOR RENOVATION OF TWO HOUSING UNITS AT THE ANACORTES"SITE 1 GENERAL -y`` AT © 719 Q.A COMPLEX." THE FIRST FLOOR AREA OF EACH UNIT IS 492 SQUARE FEET. THE SECOND REFERENCE ACT ACOUSTIC CEILING TILE DETAIL AFF ABOVE FINISHED FLOOR ® ANACORTES, WA 98221 FLOOR AREA OF EACH UNIT IS 511 SQUARE FEET. TOTAL GROSS SQUARE FEET OF THE G0.00 COVER SHEET PROJECT IS 2003. G0.01 PROJECT INFORMATION, DRAWING INDEX AHU AIR HANDLING UNIT ARCHITECTURE INTERIOR DESIGN ALT ALTERNATE REPLACE ALL FLOORING AND BASEBOARD, NEW FIRST FLOOR KITCHEN LAYOUT AND ARCHITECTURAL zervasgroup.com © FIXTURES, NEW SECOND FLOOR CABINETRY AND PLUMBING FIXTURES, REINSULATE 209 Prospect tibet ALUM ALUMINUM DESIGN TEAM Bellingham,WA 98225 AV AUDIO/VISUAL BLDG SECTION ALL EXTERIOR AND PARTY WALLS. NEW GWB WALL COVERINGS AND PAINT. A2.01 FLOOR PLANS 380.734.4744 9 BLDG BUILDING A2.02 RCP AND SCHEDULES CLG CEILING W MECHANICAL AND ELECTRICAL UPDATES TO CODE COMPLIANT FIXTURES. A5.01 INTERIOR ELEVATIONS CLR CLEAR ARCHITECTS A8.01 INTERIOR DETAILS CMU CONCRETE MASONRY UNIT ZERVAS 5 REGISTERED COL COLUMN 209 PROSPECT STREET ELECTRICAL CONC CONCRETE i®\ BELLINGHAM, WA 98225 0 A: COST CONTINUOUS WALL SECTION 360-734-4744 E1.01 ELECTRICAL-NOTES, LEGEND 8 INDEX CPT CARPET ELECTRICAL E2.01 ELECTRICAL- FIRST FLOOR PLANS �` CT CERAMIC TILE K ENGINEERS PROJECT DATA E2.02 ELECTRICAL-SECONDISER FLOOR PLANS \ , E6.01 ELECTRICAL-RISER DIAGRAM, PANEL SCHEDULE, LIGHT FIXTURE SCHEDULE 'ON C. '•BIN50 STATE a wASHiNoroN DIA DIAMETER 208 3RD ST DIM(S) DIMENSION(S) X LYDEN,WA 98264 DN DOWN S DR DOOR X 4 AX.XX X INTERIOR ELEVATION SITE: DS DOWNSPOUT ZONE R-3 DTL DETAIL X DWG DRAWING SITE ADDRESS: 508 6th Street#6,Anacortes WA 98221 DWR DRAWER AND (E) EXISTING 19 DOOR TAG 508 6th Street#5,Anacortes WA 98221 EA EACH x ELEC ELECTRICAL ELEV ELEVATOR OR ELEVATION ROOM NAME ENL ENLARGED # ROOM NAME/NUMBER EQU EQUAL EXIST EXISTING EXT EXTERIOR (F) FUTURE 4 ELEVATION DATUM F-C FIBER CEMENT FCP FIBER CEMENT PANEL FE FLOOR DRAIN FE FIRE EXTINGUISHER COLUMN GRID FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FF SAM FOIL FACED SELF-ADHERED MEMBRANE FLR FLOOR FRT FIRE RETARDANT TREATED I 1 I WALL TAG FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR ` I� GA GUAGE GALV GALVANIZED GLB GLUE LAMINATED BEAM GWB GYPSUM WALL BOARD O WINDOW TAG HB HOSE BIB HR HOUR INSUL INSULATION HC HOLLOW CORE HM HOLLOW METAL HT SAM HIGH TEMP RESISTANT SELF-ADHERED MEMBRANE REVISION INDICATOR HSS HOLLOW STEEL SECTION ILO IN LIEU OF LF LINEAL FEET INT INTERIOR REVISION NUMBER MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTL METAL • �s • R (N) NEW • NA NOT APPLICABLE `# Y NFVA NET FREE VENT AREA *- r ` NIC NOT IN CONTRACT ;; �GA Vo�O OC ON CENTER V OD OUTSIDE DIAMETER — " • - OPP OPPOSITE — ._ ; I j w� w OH OPPOSITE HANDYP 4 a ORWL OVERFLOW RAIN WATER LEADER ,:;,� "' y V + -'` S 0 PLYWD PLYWOOD � 5 •; y�� g'` � s �, ! z c_ PNT PAINT OR PAINTED € - x� !" ' g PT PRESSURE TREATED a.'11 ' -''' WS I • f' — fi R RISER - ' r, REF REFERENCE OR REFRIGERATOR READ REQUIRED RCP REFLECTED CEILING PLAN ;i esti z '� o _ A ' VV REQ REQUIRED R&S ROD AND SHELF .� ): RD ROOF DRAIN -- '; gyp+ RO ROUGH OPENING \ RM ROOM r _h: � R a RWL RAIN WATER LEADER SC SOLID CORE 1 • SF SQUARE FOOT/FEET 6TH STREET e 6TH STREE ` PERMIT SET SHWR SHOWER . — - _ n SHT SHEET w_ ��-4 . SI SQUARE INCH(ES) 4 '+. ` - -, - SIM SIMILAR (' Y; SPEC SPECIFIED OR SPECIFICATION :: SQU SQUARE - M Ag' REV ISSUED FOR DATE SS STAINLESS STEEL STL STEAL ' ?',� 3 ST STREET - - STRUCT STRUCTURAL • T TREAD s �.. - - , . . TPD TOILET PAPER DISPENSER TO TOP OF TOC TOP OF CONCRETE VICINITY MAP TOS TOP OF STEEL PROJECT LOCATION TYP TYPICAL N.T.S. UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD VT VINYL TILE W/ WITH W/O WITHOUT WC WATER CLOSET ANACORTES WD WOOD WF WIDE FLANGE W HOUSING RB WEATHER RESISTIVE BARRIER WWF WELDED WIRE FABRIC AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY PROJECT INFO. DRAWING INDEX VICINITY MAP PROJECT No: 201711.05 DRAWN BY: ZN CHECKED BY: SCR DATE ISSUED: 04/01/19 G0.01 ©2014 LINES OF ADJACENT LtIT V ,. \ II DEMOLITION NOTES MIRROR PLAN AND DI ENSIGNS FOR ADJACENT UNIT, TYP. �_ A rll — 1. REMOVE ALL WALL AND CEILING PLASTER,GWB THROUGHOUT. I , , 2. REMOVE INSULATION IN ALL EXTERIOR AND PARTY WALLS. LINES OF ADJACENT UNIT INTERIOR ARCHITECTURE I DESIGN MIRROR PLAN AND DIMENSIONS zervasgroup.com 3. REMOVE FLOORING THROUGHOUT UNITS, PRESERVE SUBFLOOR WHERE ells rh m,WA FOR ADJACENT UNIT,TYP. Bellingham, 98225 POSSIBLE AND REPLACE WHERE NECESSARY. REMOVE ALL BASEBOARD. 360.734.4744 4. REMOVE ALL INTERIOR SWINGING AND CLOSET DOORS, FRAME, HARDWARE. DOORS AND HARDWARE TO BE RE-USED AT OWNERS DISCRETION. " 5 REGISTERED 1 5. REMOVE ALL INTERIOR DOOR AND WINDOW TRIM. A: 6. REMOVE ALL KITCHEN AND BATHROOM CASEWORK,APPLIANCES,AND ��� PLUMBING. CONFIRM SALVAGE OF ITEMS WITH OWNER. ON C. ' .BINSO STATE OF WASHINOTON 7. SELECTIVE DEMOLITION AS NEEDED FOR PROJECT SCOPE. 8. SHORE UP SECOND FLOOR JOISTS FOR REMOVAL OF FIRST FLOOR EXISTING SOFFIT FRAMING 27'-7"V.I.F. WALLS. TO REMAIN f DEMO EXISTING KITCHEN 3' 0„ PLAN LEGEND CASEWORK AND WALLS. EXISTING EXTERIOR PATIO TO REMAIN • l DEMOLITION ITEM ` nI I GENERAL NOTES — I o -- - - li^ I �-- 0 O --}-- I D ;:�� .I r==1 / �� 1 II + 1 II — ::/2i1: KITCHEN 1.ALL INTERIOR WALLS ARE UNRATED(ASSEMBLY BELOW)U.N.O. r L--J 101 A I 5/8" GWB (EXISTING)WOOD STUDSI LAZY SUSAN CORNER I B 3 1/2"SOUND BATT I II i — CABINET DINING W 5/8" GB I ii i Al A5.03 C Cr* 102 LIVING 2. MATCH ALL EXISTING LEVELS OF FIRE PROTECTION, INCLUDING INTERIOR L_�_J IIL IL I DII - r A 103 WALLS, PARTY WALLS, SOFFITS, CAVITIES,AND DRAFT STOPS. — I — 'J� I > 3. USE 1/2"CEMENTITIOUS BACKERBOARD IN LIEU OF GAB AT TUBS/TUB OPEN UNDER COUNTER b ENCLOSURES. I3 I FOR SEATING,THIS AREA 4. SEE INTERIOR ELEVATIONS FOR ADDITIONAL WALL FINISHES. � MBoa 5. PROVIDE 1 HR FIRE SEPARATION PER CODE AND CITY REGULATIONS AT —pm... ___; I I W W / D VP ALL PARTY WALLS AND CEILINGS BETWEEN DWELLING UNITS. EO EO 6. HANG,TAPE,TEXTURE NEW GB (SEE SPEC). W / D / MECHANICAL PLAM SHELF, INCLUDE ROD 104 7. REINSULATE EXTERIOR AND PARTY WALLS BETWEEN DWELLING UNITS. v ) F / ) F INCLUDE SOUND BATT INSULATION IN PARTY WALL. ( AD EXISTING STAIR TO REMAIN, / EXISTING WASHER/DRYER TO REMAIN EXISTING MECHANICAL CLOSET FRAMING TO REMAIN APPLY NEW FLOORING REMOVE ALL EXISTING SLIDING DOORS NEW UNIT PANEL, REPLACE EXISTING INCLUDE NON-COMBUSTABLE PLYWOOD (SEE BACKINGELECTRICAL). EXISTING FURNACE TO REMAIN rTh FIRST FLOOR PLAN - EXISTING / DEMO (\ FIRST FLOOR PLAN - PROPOSED / FINISH PLAN 1 / SCALE: 1/4"=1'-0" \ 1 y SCALE: 1/4"=1'-0" r_. _ _ _ i _ LINES OF ADJACENT UNIT! MIRROR PLAN AND DIMENIONS 1 L , L 7 FOR ADJACENT UNIT, TYP. rill 1/ L LINES OF ADJACENT UNIT MIRROR PLAN AND DIMENSIONS FOR ADJACENT UNIT,TYP. -- T? Fri_ _ 1 1 1 L- J PERMIT SET DEMO AND REMOVE ALL EXISTING PLUMBING FIXTURES IN BATHROOM 204 28'-7) "V.I.F. .. i i .. REV ISSUED FOR DATE n , . i /' -11rj11 I ci II 0 �` II B _ Al A5.03 C r r O1 p �� PLAN NORTH TRUE NORTH L_ n �� BEDROOM c----- �� BATHROOM I I I 202 SCALE: 1/4"=1'-0" ��� C A) 1204 = 0 4 * \` 0 y;p`� BEDROOMO ��+ J y1 rANACORTES _ III— ty* CA) o HOUSING �A� ��s' �A. t2401A HALLWAY IL AUTHORITY / Aga ;?. _ A� /EN' A, 205 U ;�^ • (A) SITE 1 s ,, , I' �- --- ,__,I— I I P MVP ANACORTES HOUSING �WH, ��g. — — 1 WH zoos AUTHORITY �'k� ,s° BEDROOM y I / 203 FLOOR PLANS - � S r - - - - S PROJECT No: 201711.05 / \ / DRAWN BY: CHECKED BY: ZN SCR REMOVE EXISTING WATER HEATER PLAM SHELF, INCLUDE ROD IN ALL BEDROOM CLOSETS DATE ISSUED: 04/01/19 REMOVE ALL EXISTING INTERIOR DOORS REPLACE WATER HEATER WITH GAS TANKLESS HEATER �� .O 1 2014 iE2. SECOND FLOOR PLAN - EXISTING / DEMO () SECOND FLOOR PLAN - PROPOSED / FINISH PLAN \ / SCALE: 1/4"=1-0" \ L J SCALE: 1/4"=1'-0" 7 FINISH KEY `\ SYMBL. CODE ITEM DESCRIPTION REMARKS RCP NOTES I RFS-1 RESILIENT FLOORING-SHEET MANUFACTURER: MANUFACTURER: - II A \\\\\\�\\\\ MATERIAL: MATERIAL: =� 1.ARCHITECTURAL RCPS FOR DIMENSIONING OF CEILING FIXTURES ONLY. COLOR: COLOR: A SEE ELECTRICAL PLANS FOR SPECIFICATION AND LAYOUT. A 4 I LINES OF ADJACENT UNIT FINISH: FINISH: ARCHITECTURE I INTERIOR DESIGN 2. MATCH ALL EXISTING LEVELS OF FIRE PROTECTION, INCLUDING INTERIOR MIRROR PLAN AND DIMENSIONS GAUGE: GAUGE: zervasgroup.com 209 Prospect WALLS, PARTY WALLS, SOFFITS, CAVITIES,AND DRAFT STOPS. FOR ADJACENT UNIT,TYP. CONTACT INFO: CONTACT INFO:MANUFACTURER: MANUFACTURER: Benl� A7 744 9822t5 360.734.4 3. DIAGONAL CENTERLINES DENOTES A FIXTURE CENTERED WITHIN A SPACE. MTL-1 METAL STAINLESS STEEL MATERIAL: MATERIAL: B COLOR: COLOR: FINISH: FINISH: �55 REGISTERED GAUGE: GAUGE: ail) CONTACT INFO: CONTACT INFO: , / i EXTEND SOFFIT TO COVER 'ON C. ' F BINSO O REFRIGERATOR,ALIGN WITH P-1 PAINT MANUFACTURER: MANUFACTURER: STATE OF WASHINGTON CLOSET DOOR COLOR: COLOR: LINE OF EXISTING SOFFIT PL-1 PLASTIC LAMINATE MANUFACTURER: MANUFACTURER: - 6 D PATTERN/COLOR: PATTERN/COLOR: COU(JTER EQ E EQ EXISTING SOFFIT AT DROPPED E GE i BEAM. REPLACE GAT INSTALLATION TYPE: INSTALLATION TYPE: I — — WD-1 WOOD MANUFACTURER: MANUFACTURER: - - i 62 1 I 1 --------- I CED PATTERN/COLOR: PATTERN/COLOR: Fir1 // CUT CUT w z I �� I I — 7 CEILING HT-MATCH INSTALLATION TYPE: INSTALLATION TYPE: O w V EXISTING,TYP. / U CEILING HT-MATCH i• 0. - / CONTACT INFO: CONTACT INFO: EXISTING,TYP. RB-1 RESILIENT BASE MANUFACTURER: MANUFACTURER: - O / SERIES: SERIES: • z ) F —. / O COLOR: COLOR: z HEIGHT: HEIGHT: co CONFIGURATION: CONFIGURATION: - EQ 1, EQ 7, 0 0 1 ROOMNAME NOTE: O P. _ __,_ _ A200 © -INSTALL RUBBER BASE AT BASE OF ALL CABINETS,TY o CEILING HT-MATCH / EXISTING,TYP. / K K K PIP -SEE REFLECTED CEILING PLANS FOR CEILING FINISHES 1 1 I / -CORNER GUARDS NOT SHOWN ON INT ELEVATIONS FOR CLARITY 40 1— — i N. 3 / LINE OF BUILDING SECOND / FLOOR SOFFIT ABOVE OFIRST FLOOR PLAN - RCP SCALE: 1/4"=1'-0" DOOR SCHEDULE DOOR SYMBOL KEY: DOOR NUMBER ink r__ — —I v v DOOR NW HARDWARE I � ---1 I z MARK GROUP O_ co � Z 1.ALL DOORS ARE 1 3/4" U.N.O. *MATCH HEIGHT OF EXISTING DOORS, `L F- 0 CI- ›.- 2 VERIFY 7'-0" IN FIELD BEFORE ORDER. QF 2. DOOR CONSTRUCTION: M m Z i CO Q W TYP=SOLID CORE FLUSH FACE WOOD 0 LU Y Cl) Z HC= HOLLOW CORE F1 1 L D I- Z U W LV= LOUVERED WOOD AL=ALUMINUM &GLASS L �� O DOOR SIZE VVXD = O Q LINES OF ADJACENT UNIT 0 (1) (8) I- U u U` LT_ �+ 3. FACING AND FINISH: MIRROR PLAN AND DIMENSIONS 1 3'8"X6' e- " A TYP -rep TYP=HIGH PRESSURE DECORATIVE WOOD LAMINATE FOR ADJACENT UNIT,TYP. MP=METAL PAINTED PL= PLASTIC LAMINATE _ 2 6'-01(6'-8" B - LV TYP - - WD HP= HARDBOARD LAMINATE AL=ALUMINUM CLEAR ANODIZED 3 5'-0'x6'-8"* A TYP TYP WD 4. GLASS L I LS= LAMINATED SAFETY 4 2'-6"X6'-8"• C TYP TYP gyp TI =TEMPERED INSULATED 5. 1/3, 1, 1.5, ETC. INDICATES HOUR OF FIRE RATING 5 31-0"X6'-6"• C - TYP TYP - 6. DOOR TYPE: SEE DRAWING - WD 7. FRAME TYPE: PERMIT SET HM= HOLLOW METAL(SEE DRAWING) 6 r s'xs's- "• C TYP TYP WD WD= WOOD FRAME AND TRIM (SEE DRAWING) AS=ALUMINUM STOREFRONT, SEE A3.01 28'-7y2"V.I.F. I 7 1'-8"X6'-8„* C - TYP TYP - - WD 8. 'DOOR FIELD D BEFORE ORDERING.TO MATCH EXISTING. CONTRACTOR TO CONFIRM IN REV ISSUED FOR DATE 1-1 • CEILING HT-MATCH / o N EXISTING,TYP. I CoO/ VJ— — - 0�� N. -1,—/— F- `. / — N co n N - - �z— N /, ANACORTES / T, c �. DOOR DOOR N j / I If I I b /� HOUSING O_ �" o o AUTHORITY / Wo - - / SITE 1 II IIL I I / ANACORTES HOUSING �— / AUTHORITY to RCP AND I - \ /-/ /// / SCHEDULES PROJECT No: 201711.05 \ / >y ♦ v LOUVRED PANEL DOORS DRAWN BY: ZN A B TO MECHANICAL RM C CHECKED BY: SCR DATE ISSUED: 04/01/19 K SECOND FLOOR - RCP 3) INTERIOR DOOR TYPES A2 .02 2...) SCALE: 1/4"=1'-0" SCALE: 1/2 =1 -0 O4 i ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 360.734.4744 OPEN SHELVING FROM UPPER 5 1•41) REGISTERED CABINET TO CORNER. LAMINATE COUNTERTOP AND �i,r C. /BINSO BACKSPLASH. STATE OF WASHINGTON NEW SOFFIT ABOVE CABINETS ONLY, ALIGN WITH EXISTING SOFFIT. NEW SOFFIT ABOVE ('IJ) CABINETS ONLY, ALIGN WITH 6" NEW EXTENSION OF SOFFIT EXISTING SOFFIT. /¢ 11_0a1 ll EXISTING SOFFIT STRUCTURE A 9 'ti'l X / , . , `> �- �'�, j. to '' , [1----- CD7 - P P - D , \CD) 7 N CD NI o p _ p p / r3 I I A8.o1 fO 9', _,> �,11 1 / ,- ,r \ \A8.0) 2 1'-6"- _ Ihr / 'e B �c� io 00 Co e W W / SIN 0 —IN ; I n CIOV—/• , , A i i 1 / - d �__ �, \ / O r ) CrTh ry ( O, / �' y'� W O, Oltv `� / �� T� o*�7./ / I / � i . V - I \ 1 L 1 _ J `- Cr.)- 1" \,„ 2'-0" 3'-0" 1'-0" 2'-0" 2'-0" /1'-0" 2'-6" 11-6" / 2'-72' / 1'-6" / 1'-6" / 1' 6" / 1'-9" / STAIR FRONT DOOR DISH- OVEN REF PANTRY LIVING ROOM LANDING WASHER BACKSPLASH GLUED. N o TOP OF STOVETOP TO y UNDERSIDE OF HOOD. " KITCHEN ELEVATIONS \ / KITCHEN ELEVATIONS SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" OPEN UNDER COUNTERTOP FOR SEATING PROVIDE TOWEL BAR S SPR MEDICINE PROVIDECABINET SIDE PANEL TO SUPPORTL._ / 1 L �J CURTAIN ROD AND PAPER HOLDER. LA EEMINATE EC COUNTERTO FO NI PROVIDE TOILET silD COUNTERTOP ( D.) AND BACKSPLASH PERMIT SET CD) ■ O / CFI I C-F ) e -� REV ISSUED FOR DATE PROVIDE TOILET ti-li. 2 2'-7" MIN (BEYOND SIDE PANEL) PAPER HOLDER. OPEN UNDER COUNTERTOP 2-1 1 -4 2-8 / A8.o1 n u n N J FOR SEATING / �N tyi C rN J I �� SCALE: 1/2„=1�_0�� rz��� __ _- \-- , , ( r� 0 2' w CD> M iri` SIN ll D 11 / < n „, .�' , �, \ i ;n W. N /fie ANACORTES w I \---- iliali © HOUSING �% C F I C (F ) 1►. AUTHORITY \ \ 1'-6" il, 1r_6" 1r 6" I 1'-0" lii; EQ EQ SITE 1 3,r AP' Jr 3 2 SEE SPEC FOR TUB / 3 0" / ANACORTES HOUSING \ 4 4'-72' \ 4 3.0 fc��h • T��2`r ENCLOSURE / / AUTHORITY / /(FACING INTERIOR ELEVATIONS REFRIGERATOR) KITCHEN / BATHROOM ( Th BATHROOM ELEVATIONS 0---3) BATHROOM ELEVATIONS BATHROOM ELEVATIONS i 1 BATHROOM ELEVATIONS PROJECT No: 201711.05 �- KITCHEN ISLAND ELEVATIONS AC� .D2 DRAWN BY: ZN C / SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" _ SCALE: 1/Z'=1'-0" \ SCALE: 1/2"=1'-0" CHECKED BY: SCR / SCALE: 1/2"=1'-0' \ / DATE ISSUED: 04/01/19 A5.01 �zo,a 1111 SEE WALL TYPE CENTER PULLS IN 6"TALL i 19 +� TOP DRAWERS,TYPICAL \ INTERIOR so EXTERIOR I I \ I 5/8"GWB (TYP) ARCHITECTURE I INTERIOR DESIGN PT. 1 5/8"GWB. (fYP) zervasgroup.com PER ELEV. �� FINISH AS FINISH AS 209 Prospect Street •1" I \% , Bellingham,WA 98225 I u SCHEDULED I � SCHEDULED so 360.734.4744 i tr.„2 `� 4"RUBBER BASE I, �! i4" RUBBER BASEkil ill IIi N \% iv �i,so� EXTERIOR WINDOW FLOOR FINISH PER L_______., _ ► � v �� `�; 4 TRIM TO REMAIN SCHEDULE _ `SEE SPEC FOR 6455 REGISTERED \ �'' _ �%I\ ��� —I HARDWARE SELECTION, ,` A: \"!�` `Fiw�m�to:'_ VARIES PER LOCATION \t A tabs: 1'0• , /BINSO ir Ltd1/4" EXISTING WINDOW TO SUBFLOOR i ' .,1/4" //• LINE OF FULL HT1111111 REMAIN EXISTING suTE .otoM LINE OF FULL HT SIDE CASING BEYOND — SIDE CASING BEYONDJAM EXTENSION ASI 1 1/2"DOORi'sIII NEEDED TO MEET NEW 2 / HEAD AND SIDE CASING I TYP DOOR HEAD TRIM DETAIL TYP WINDOW HEAD TRIM DETAIL 9 RUBBER BASE @ FLOORING, VARIOUS TYP CABINET HARDWARE MOUNTING LOCATION 2SCALE: 10 SCALE: 3"=1'-0" 3"=1'-0" SCALE: SCALE: 3"=1'-0" LINE OF FULL HT SIDE CASING BEYOND, 111 WHERE FLOOR SURFACE IS TERMINATE INTO STOOL EXTERIOR WINDOW ir NOT CONTINUOUS, RUN INCLUDE WINDOW TRIM TO REMAIN FLOOR SURFACES TO BLINDS,TYPICAL EXISTING WINDOW TO CENTER OF DOOR, INSTALL REMAIN Schluter-SCHIENE TRANSITION 1/2^ III1J11 STRIP @ TRANSITIONS.NO THRESHOLD READ. 1�, WHERE FLOOR SURFACE IS `sr rr��1M��� /` \\ CONTINUOUS© BOTH SIDES II// �� OF DOOR. ` I 'i SA411 RABBETED PLAM nWINDOW STOOL os \ 1 INTERIOR I` EXTERIOR \ '' w• ALIGN TOP OF CABINET �` 1 1-0" WITH EXISTING 7'-0"SOFFIT / -..C...'t \ LINE OF EXISTING \ i SOFFIT BEYOND \ (2) TYP DOOR THRESHOLD DETAIL TYP WINDOW STOOL DETAIL \ SCALE 3"=1'-0" SCALE: 3"=1'-0" r ,. PLAM ADJUSTABLE SHELF SIDE CASING ` LINE OF WINDOW SILL 1/4" • / BEYOND 31/2" 1/2" 3 1/2" " � �ria I 1 iv JAM EXTENSION AS PLAM ON ALL NEEDED TO MEET NEW el '�1��i� HEAD AND SIDE CASING \ INTERIOR SURFACES 6.���r � ;l J / PULL HARDWARE witi 919 A ='! I MEDICINE CABINET, *�_ I MEDICINE SPEC, MOON ill __ as �' MANUFACTURERS 1/2 'r!/'� EXISTING WINDOW TO WY as RECOMMENDATIONS 3/4" REMAIN LINE OF BASEBOARD EXTERIOR WINDOW / 2'-1" / PERMIT SET BEYOND TRIM TO REMAIN LAMINATE COUNTER — LAMINATE COUNTER 2'-1" OVER SUBSTRATE OVER SUBSTRATE ill DRAWER ,t , (V N REV ISSUED FOR DATE TYP DOOR SIDE CASING TRIM DETAILcl) TYP WINDOW SIDE CASING TRIM DETAIL 3 �. J///l//// %/i/////// / / U!/////////UL� SCALE: 3"=1'-0" SCALE: 3"=1'-0" -- I _ <I Ix L / Zs) 0 Ad st ii• , ANGLE IRON AS REQ. 1.111 N N STATIONARY PANEL IIIII SCALE: AS NOTED r� ci 1 J T� 1 I I J 111 • . ANACORTES FLAT HEADCASING FLAT HEADCASING N PLAM N .-- TERMINATE SIDECASINGIII TERMINATESIDECASINGINTO A JU •STAB E 9 ADJUSTABLE N HOUSING INTO UNDERSIDE OF 1/4" UNDERSIDE OF HEADCASING 1/4" SHELF�,TYP. " SHELF X2,TYP. N i AUTHORITY HEADCASING4 .; 1 I I I SITE 1 RAM ON ALL PLAM ON ALL TERMINATE SIDECASING INTO STOOL 1/2"„ / INTERIOR / INTERIOR : ANACORTES HOUSING PLAM WINDOW STOOL // SURFACES // SURFACES • a AUTHORITY FLAT SIDECASING / —_,,v> v , \ ft \ i' INTERIOR TERMINATE BASEBOARD a V v INTO SIDECASING I. A BUILDING DETAILS i. PROJECT No: 201711.05 PLAN BASE TO 61, 3" PLAN BASE TO ,le 3 DRAWN BY: ZN MATCH CABINET MATCH CABINET CHECKED BY: SCR im TYP BASE & DOOR TRIM DETAIL ELEVATION TYP WINDOW TRIM DETAIL ELEVATION 6-2 BATHROOM CASEWORK SECTIONKITCHEN CASEWORK SECTION DATE ISSUED: 04/01/19 �4/ SCALE: 3"=1'-0" CSCALE: 3"=1'-0" �� SCALE: 11/2"=1'-0" SCALE: 1 1/2"=1'-0" A8 .01 Ce)2014 NOTES (APPLICABLE TO ALL ELECTRICAL DRAWINGS): ELECTRICAL RICAL LEGEND ARCHITECTURE I INTERIOR DESIGN 1. ALL SYSTEMS, EQUIPMENT, DEVICES, RACEWAYS, CABLES, ETC. INDICATED ARE zervasgroup.com NEW 209 Prospect Street UNLESS SPECIFICALLY NOTED AS EXISTING. Bellingham,WA 98225 LIGHTING OUTLETS MISCELLANEOUS 360.7 4.4744 2. THE ELECTRICAL WORK SHALL INCLUDE ALL WORK SHOWN ON THE DRAWINGS, DETAILS, DIAGRAMS, SCHEDULES, ETC., AND AS DESCRIBED IN THE SPECIFICATIONS. LUMINAIRE,SURFACE MID. S DUPLEX OUTLETS BRANCH CIRCUIT,ABOVE GRADE,CONCEALED(OR SIMILAR K ENGINEERS INC. SLASHES 2 NO.CF CIRCUIT CONDUCTORS WHERE APPLICABLE. 3. PLAN DRAWINGS ARE DIAGRAMMATIC IN FORM AND DO NOT ATTEMPT TO SHOW CI LUMINAIRE,PENDANT MTD. t DOUBLE DUPLEX OUTLET CIRCUITS ARE 2 CONDUCTOR UNLESS NOTED OTHERIUISE, 208 Third Street COMPLETE DETAILS OR LIST EVERY ITEM OF THE ELECTRICAL SYSTEM, EQUIPMENT, 14 AUG FOR 15A CIRCUITS 1 @FOR 20A CIRCUITS) Lyndon, WA. 98264 Il 1I LUMINAIRE,WALL MID. S DUPLEX OUTLET,GROUND FAULT INTERRUPTING Bus. (360) 354-4757 OR BUILDING CONSTRUCTION; HOWEVER, THE ROUTING OF RACEWAYS AND CIRCUITS, BRANCH CIRCUIT,ABOVE GRADE,EXPOSED FAX 360 354-6794 THE LOCATIONS OF EQUIPMENT, DEVICES AND FIXTURES REPRESENT THE DESIRED ( i STRIP LUMINAIRE et DUPLEX OUTLET,WEATHERPROOF FINISHED ARRANGEMENT. — -s HOMERUN TO LCCATICN INDICATED,CONCEALED(TYPICAL) 0 RECESSED DOWNLIGHT ® SPECIAL PURPOSE OUTLET 4. RACEWAYS AND CABLES THROUGHOUT THE FACILITY SHALL BE RUN CONCEALED IN R. D NOhIETdBJ TO LOCATION INDICATED,EKt'OSEp(TYPICAL) Ns. THE WALLS, ABOVE THE CEILING OR BELOW THE FLOOR WHERE POSSIBLE, EXCEPT, i LUMINAIRE,WALL MW 0 SPECIAL PURPOSE CONNECTION ?' of was A EXPOSED WITHIN UTILITY & OTHER NON-PUBLIC SPACES. WITHIN PUBLIC SPACES, EXISTING CONDUIT,NEW CABLE �� ���!�� WHERE DUE TO THE BUILDINGS CONSTRUCTION, IT IS NOT POSSIBLE TO ROUTE LUMINAIRE,CEILING MTD d IDIT TELECOMMUNICATIONS OUTLET,FLUSH MOUNTED -20 i ,��v.. RACEWAYS & CABLES CONCEALED, RACEWAYS MAY BE RUN EXPOSED. EXPOSED (IDIT = I CATS I COAX CABLE,TYPICAL) — BELOW GRADE CONDUIT ( ! t�0 RACEWAYS SHALL BE RUN AS NEATLY & UNOBTRUSIVELY AS POSSIBLE, SUPPORTED /' "'� ,GROUND CABLE ' 44794 CTI� 4'z. AS REQUIRED, PARALLEL OR AT RIGHT ANGLES TO CEILINGS, WALLS & STRUCTURAL • �� ® 1v MEMBERS. ANCILLARIES `""--"---'--� COMM CABLE (ROUTED OPEN WITHOUT RACEWAY) ONAL 5. RACEWAYS AND CABLES SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: SWITCHING 05 FIRE ALARM SMOKE DETECTOR © JUNCTION BOX A. BRANCH CIRCUIT INTERIOR ACCESSIBLE CONCEALED SPACES- ROMEX (TYPE NM) S SINGLE-POLE SWITCH FIRE ALARM SMOKE DETECTOR,WALL MOUNTED DISCONNECT SWITCH S3 THREE-WAY SWITCH O DOORBELL BUTTON ® PANELBOARD B. FEEDER INTERIOR ACCESSIBLE CONCEALED SPACES -EXISTING TYPE ELECTRICAL METALLIC TUBING (EMT)WITH NEW CABLE. IMER SWITCH Sit DOORBELL STROBE/CHIME EXHAUST FAN C. INTERIOR, EXPOSED IN ROOMS, CORRIDORS &THE LIKE WHERE READILY 0 THERMOSTAT OT DOORBELL POWER SUPPLY ® FAN/LIGHT COMBINATION VISIBLE TO BUILDING OCCUPANTS - SURFACE METAL RACEWAY (SMR). WP WEATHER PROOF D. EXTERIOR ABOVE GRADE - GALVANIZED RIGID STEEL CONDUIT(GRS). DEMOLITION EX EXISTING TO REMAIN E. EXTERIOR BELOW GRADE - POLYVINYL CHLORIDE CONDUIT(PVC). €J<= REX REPLACE EXISTING F� REL RELOCATE EXISTING 6. RACEWAYS SHALL BE SIZED SO THAT THE CABLE FILL DOES NOT EXCEED 40%, y--( DEMOLISH EXISTING DEVICE, INCLUDING EXCEPT, MINIMUM CONDUIT SIZES SHALL BE NOTED ON THE DRAWINGS. ) 1 ALL ASSOCIATED WIRING,BOXES,SUPPORTS, RUT FUTURE ETC.,EXCEPT EXISTING BOXES MAY REMAIN 7. DEVICE BOX SIZES SHALL BE SIZED IN ACCORDANCE WITH NEC FOR BOX FILL, AND IF THEY ARE SUITABLE FOR THE NEW SHALL BE SUITABLE FOR USE WITH THE WIRING METHODS USED. INSTALLATION C`F) 8. DEVICE MOUNTING HEIGHTS SHALL BE AS FOLLOWS, UNLESS SPECIFICALLY NOTED Q OTHERWISE. MOUNTING HEIGHTS SHOWN ON THE DRAWINGS ARE TO THE CENTER OF THE BACK BOX FROM THE INTERIOR FINISHED FLOOR. A. POWER, TELECOMMUNICATIONS, AUDIONIDEO, ETC. RECEPTACLES - 18" B. LIGHTING SWITCHES, CONTROL STATIONS, ETC. -44" C. DEVICES ABOVE COUNTERS -4" ABOVE BACKSPLASH. 9. TELECOMMUNICATIONS CONDUITS SHALL BE PROVIDED WITH PULL ROPES BELOW GRADE AND PULL STRINGS ABOVE GRADE. EXISTING CONDUITS TO BE USED SHALL BE FISHED AND CLEANED PRIOR TO INSTALLATION OF CABLES. 10. BRANCH CIRCUIT CABLES, EQUIPMENT GROUND CABLES AND ABOVE GRADE FEEDER CABLES SHALL BE 2/C COPPER, #12 AWG UNLESS NOTED OTHERWISE, WITH 600V TYPE NM CABLE . 11. PROTECT"OPEN" CABLE WIRING FROM ROUGH AND/OR SHARP EDGES ON SUPPORTS, STRUCTURAL MEMBERS, ETC. AS REQUIRED DURING INSTALLATION. 12. LABELING & NAMEPLATES: A. OUTLETS SHALL BE LABELED WITH THE PANEL AND CIRCUIT NUMBER FROM WHICH ITS FED. LABELS SHALL BE HEAVY DUTY ADHESIVE TYPE, CLEAR TAPE WITH BLACK LETTERING, MADE WITH A LABEL PRINTING DEVICE. B. JUNCTION BOXES SHALL BE LABELED WITH THE PANEL AND CIRCUIT NUMBER CONTAINED WITHIN. MARKING SHALL BE LEGIBLY HAND-WRITTEN WITH BLACK INDELIBLE MARKER. C. PANELBOARDS AND FEEDER BREAKERS SHALL BE PROVIDED WITH PHENOLIC NAMEPLATES, BLACK FACE, WHITE CORE, ENGRAVED WITH 1/8" LETTERS. n 1 _ D. SWITCHBOARDS AND PANELBOARDS SHALL BE PROVIDED WITH PHENOLIC SET NAMEPLATES TO IDENTIFY THE SYSTEM COLOR CODING SCHEME FOR PHASE AND NEUTRAL CONDUCTORS. E. SWITCHBOARDS AND PANELBOARDS SHALL BE PROVIDED WITH LABELS TO REV ISSUED FOR DATE WARN PERSONNEL OF POTENTIAL ARC FLASH AND SHOCK HAZARDS. PLAN NORTH TRUE NORTH SCALE: NONE limil.• 0 X' ANACORTES HOUSING DRAWING INDEX AUTHORITY SITE 1 SHEET DRAWING TITLE E1.01 ELECTRICAL- NOTES, LEGEND& INDEX ANACORTES HOUSING E2.01 ELECTRICAL- FIRST FLOOR PLANS AUTHORITY E2.02 ELECTRICAL-SECOND FLOOR PLANS ELECTRICAL p E6.01 ELECTRICAL-POWER SYSTEM RISER DIAGRAM, PANEL& LIGHTING FIXTURE SCHEDULES NOTES]LEGENDO INDEX PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 E1 .01 ®2010 I _ _ _ j ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 A. 360.734.4744 K ENGINEERS INC. 208 Third Street Lyndon, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 R. D tiA of wA A v � q: ifl N °t df SIONAL Dr MULTI-METER PACK (REPLACE EXISTING) > ] I PRYER { Bilitteia-A PRYER WASHER ^r I I C3 COMM PULL BOX 6 WITH )-� ;� id �� •v tip IP :3 •le F °J �+ NEW 3 .1 AWCs 2 EXISTING ' EMT ALUM(EAC6 ALUM GNP) E i COMM P II 2 - I' EMT (CM .1 CT. Yl _ ` _ i_in4 �4 16 II 6 ji ROUTED THROUGH r C ,c, IT P L I GOI L -JI I CRAWLSPACE) wFr, _�� ------) -- - J' ffu t IIIIIIS .inPANOVE EXISTNG Ir• • •18 I I PANEL / % 3 ^ • A 1— r gr 11 1 Q a U7_T -, rr II • •44' �'�_ = n GFI -UP �:�. .33' =1 • I - ,33' =€� ; _€ DI ING rn ki I, ,A LIVING JI - DISHWASHER ' 1��1 G 5 9, II _ DISPOSAL— HOOD / '�Ll J�� l f7 l�, /'�ik L Ir--- �3= (mil G� C� G bXU h KI HEN coral PANEL L -i rl I�===� — G �`7� r �y� At_ krAthe for _ �•�J' C , ` I =__ t.41 ,� • r •44' 74477 �44'- i� 6 LII V J �1 V '���� rib- / Arl� , or u R^V_ 'F+Y__i �,� a °�c� a �ppp �s.1 gs, T : I \a �: l, 1 LI17 V r_�_-1 v� Mw • .w \ 9,11 -----� 6 // �^ /n�y9,11 is hunc� hi 0fth/'t otno'l a ,[�„ .•y.V�r 3 I., �, , �� ',fj� 1� fr.,-All V✓A? ,,. l f ,7 „ a Vr !gam W �,:4(_; _€� '1 •44 .,- \ .as -y —.-44` GFI w, 0 l J� { '-i L___1_ -- C C e j I� = plsPosAL (r� _ HEN I Cr PANEL sac,' �'j�' R3 Oz NZ, 51 441 _€ �. Sill • _€ - DISHWASHER Ie C 5 DINING L J ' II — 'Pr WP I ' 00 - .33 LIVING i GFI r.. .44. I l- TG -I__i -J LL JL_ L —REMOVE EXISTING ,� ' PANEL `\si T ra an -� _€; 10, ti v? '� COMM PANEL c c yami? -- • — r n J €� G T 4 FACE EXI MG)io COh91 PANEL 6 SET rr .3- •Im G ©. S 6 REV ISSUED FOR DATE BaiKtE— YIR FURNACE —PRIER —WASHER —PR7EB PLAN NORTH TRUE NORTH SCALE: 1/4"=1'-0" mimIlimm 0 4' ELECTRICAL - FIRST FLOOR POWER PLAN - DEMOLITION O ELECTRICAL - FIRST FLOOR POWER PLAN - PROPOSED ® SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-O" ANACORTES HOUSING AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY ELECTRICAL 0 FIRST FLOOR PLANS PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 E2.01 ©2oi0 • . / ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 360.734.4744 K ENGINEERS INC. 208 Third Street Lyndon. WA. 98264 Bus. (360) 354-4757 FAX 360 354-6794 It v1P OF wA n .At - " 'l., N 1 ,s . ' *4;.94 _‘l r SSIONAL �yW. 14 • . 18'-0' ^w �� — --- \ \ 0 r ' il \ 1 v g, T-t nA T 1 - i\ i�i I6kili \ ••ram COMM PANEL \\�V/ r- . O. D G O �0 D r A, - a - � M y � ��� Q :n SS tip V w '. I 'PIT cat PANEL �_t n i8i " 1 P , �I —pier _r n n )—e & L rC fJSl r _ 1 Dr C�u O " cv , �_IIII� , O i - ■ ,c A� r1 a�ic v P I ,i, 0 T L.1W' 11 , - . 0 O kli ill VI C L`U r •rie n � Q • I 110 �1 �\ N �III 0 1 cc f c6, T Cr IV�I // — .IDIT M r W i ::r n mIr COW PANEL :isi�A. ' €�_ if s `iYrye 8 4 IDIT �i, .� 8 )-t / �/ 0) ' �0 D ' is, COIL PANELs' / .�! L J �� -,t I i ice. WH 1 ) yr •l� ^. Q )-A _€� • 10 I I a ti li g 0 1.--( N, / SET ___ / . 14 *A v� - 1l' I REV ISSUED FOR DATE / I/Y��O PLAN NORTH TRUE NORTH SCALE: 1/4"=1'-0" rilmi 0 4' ® ELECTRICAL - SECOND FLOOR POWER PLAN - DEMOLITION 0 ELECTRICAL - SECOND FLOOR POWER PLAN - PROPOSED SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" ANACORTES HOUSING AUTHORITY SITE 1 ANACORTES HOUSING AUTHORITY ELECTRICAL p SECOND FLOOR PLANS PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 E2.02 ®20,n /77/7" ARCHITECTURE I INTERIOR DESIGN zervasgroup.com 209 Prospect Street Bellingham,WA 98225 360.734.4744 K ENGINEERS INC. 208 Third Street Lyndon, WA. 98264 Bus. 360 354-4757 MULTI-METER PACK (REPLACE EXISTING) EXTERIOR FAX (360) 354-6794 VOLTAGE: 120240V,1 PH,3 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND TYPE: BOLT-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) MULTI-METER PACK FULL AC RATING: 22,000 A General Lighting&Outlets(3 W/SF) 12096.0 6048.0 18144.0 1Q'�g WA R. D/. A ENCLOSURE: NEMA 3R SERIES AC RATING: NONE Small Appliance&Laundry 6000.0 3000.0 9000.0 MOUNTING: SURFACE Electric Range 32000.0 16000.0 48000.0 �y�w ����,` SPECV�L PROVISIONS: Electric Clothes Dryer 14000.0 10000.0 24000.0 y ' / , r BUSSING: MANUFACTURER'S STANDARD Misc.Fixed Appliances 9706.0 4853.0 14559.0 h • 2 N CONTINUOUS RATING:600 A MASTER&FEEDER NAMEPLATES TOTAL 73802.0 39901.0 113703.0 UNIT I UNIT 2 ( i• _ �r�� 4Ib FULL AC RATING: 22,000 A Demand Factor(First 10,000W) 1.00 10000.0 44794 Demand Factor(Remainder) 0.40 41461.2 IT PANEL I IT PANEL 2 • �.�,'�Ctsgttiq 1 ' SERIES AIC RATING: NONE GROUND BAR - ONAL 0 Air Conditioning 0.0 0.0 0.0 1.00 0.0 (REPLACE EXISTING) (REPLACE EXISTNG) IOG MAIN: LUGS ONLY SUITABLE FOR USE AS SERVICE Electric Space Heating 0.0 0.0 0.0 1.00 0.0 UNIT 6 UNIT S UNIT 4 (NIT 3 LOCATION: BOTTOM ENTRANCE EQUIPMENT 25%Largest Motor 166.8 TOTAL LOAD 147604.0 79802.0 227406.0 51648.0 TOTAL AMPS 615.0 332.5 947.5 215.2 I I CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER/BRANCH CIRCUIT CONN. n n EXISTNG II/4' EMT (NEW 3 s I LOAD(VAS, DESCRIPTION NOTE AMP/P I NOJPHASE)� NO [AMP/P DESCRIPTION 143TE LOAD(VA) PANEL .'s UNIT-->• EXISTING UNIT-� EXISTING UNIT-->• Z5 25 EXISTING 4 UNIT-3. I I AWCs ALUM. + I b AUKS ALUM. DISTRIBUTION SECTION PANEL 6 PAL 5 PANEL 4 PANEL 3 g n I I ) CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT I BKR I FEEDER/BRANCH CIRCUIT CONN. (TO REMAIN) (TO REMAIN) (TO REMAIN) (TO REMAIN) ML TI-METER PACK-" 0 2n5 LOAD(VA) DESCRIPTION NOTE AMP/P NO (PHASE) NO AMP/P DESCRIPTION NDTE LOAD(VA) (REPLACE EXISTING. 25 t5 r r 9495.0 UNIT PANEL-UNIT 1 (2) 100/2 MTR 1 A 2 MTR 100/2 UNIT PANEL-UNIT2 (2) 9495.0 10431.5 I I I B I I I . 10431.5 RE-CONNECT EXISTING J 9417.0 UNIT PANEL-UNIT3 (1) 100/2MTR 3 A 4 MTR 100/2 UNIT PANEL-UNIT4 (1) 9417.0 SERVICE IFEEDER _ 9009.5 I I B I I I 9009.5 CONDUITS I CONDUCTORS - -ToEXISTNG WATER PIPING 9417.0 UNIT PANEL-UNIT 5 (1) 100/2MTR 5 A MTR 100/2UNIT PANEL-UNIT6 (1) 9417.0 AS REQUIRED) RE-CONNECT EXISTING GROUNDING ELECTRODE CONDUCTOR 9009.5 I I I B I I 9009.5 \) NOTES: \ (1) RE-CONNECT EXISTING FEEDER TO NEW CIRCUIT BREAKER. 116AUGGND (2) NEW FEEDER TO REPLACE EXISTING. EXISTING 3' PVC (EXISTING 4 EXISTING Ito' EMT(EACH WITH 3 0 I SERVICE CONDUCTORS TO REMAIN) AUKS ALUM. + I •4 AUYJ ALUM.GND) J TO PUD PADMOUNT UNIT PANEL - UNIT 1 (REPLACE EXISTING) UNIT #1 TRANSFORMER S c VOLTAGE: 120240V,1 PH,3 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND < GROUND RODS TYPE: LOADCENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) (SPACED 6 10'-0') ENCLOSURE: NEMA 1 FULL AC RATING: 10,000 A General Lighting&Outlets(3 W/SF) 0.0 3024.0 3024.0 MOUNTING: FLUSH SERIES AC RATING: NONE Small Appliance&Laundry 0.0 1500.0 1500.0 O ELECTRICAL - POWER SYSTEM RISER DIAGRAM Electric Range 0.0 8000.0 8000.0 BUSSING: MANUFACTURER'S STANDAR(SPECIAL PROVISIONS: Electric Clothes Dryer 0.0 5000.0 5000.0 NO SCALE CONTINUOUS RATING: 100 A Misc.Fixed Appliances 0.0 2426.5 2426.5 FULL AIC RATING: 10,000 A MASTER NAMEPLATE TOTAL 0.0 19950.5 19950.5 SERIES AIC RATING: NONE Demand Factor(First 10,0001M 1.00 10000.0 GROUND BAR Demand Factor(Remainder) 0.40 3980.2 MAIN: LUGS ONLY LOCATION: BOTTOM SQUARED TYPE HOM Air Conditioning 0.0 0.0 0.0 1.00 0.0 Electric Space Heating 0.0 0.0 0.0 0.40 0.0 25%Largest Motor 166.8 TOTAL LOAD 0.0 19950.5 19950.5 14147.0 TOTAL AMPS 0.0 83.1 83.1 58.9 CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER/BRANCH CIRCUIT CONN. LOAD(VA) DESCRIPTION IOTE AMP/P NO (PHASE), NO AMP/P DESCRIPTION MST' LOAD(VA) 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 1 A 2 15/1 LTG-KITCHEN AFCI 0.0 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 3 B 4 15/1 OUTLET-BATHROOM GFCVAFCI 0.0 LIGHTING FIXTURE SCHEDULE 667.0 DISPOSAL GFCVAFCI 20/1 5 A 6 15/1 LTG&OUTLETS-LIVING ROOM AFCI 0.0 931.5 DISHWASHER GFCVAFCI 20/1 7 B 8 15/1 LTG&OUTLETS-UPSTAIRS NORTH AFCI 0.0 4000.0 RANGE 50/2 9 A 10 15/1 LTG&OUTLETS-UPSTAIRS SOUTH AFCI 0.0 TYPE DESCRIPTION COLOR LUMENS VOLTS MANUFACTURER&CAT.NO. LOADS 4000.0 I 11 B 12 15/1 LTG&OUTLETS-DOORBELL,LAUNDRY&COMM F AFCI 0.0 TEMP. (OR APPROVED EQUAL) WATTS VA 0.0 SPARE AFCI 15/1 13 A 14 20/1 FURNACE AFCI - 828.0 0.0 SPARE AFCI 15/1 15 B 16 20/1 WASHER AFCI 1500.0 A CELING SURFACE MOUNTED, 14"ROUND, 3000K 2000 120 ASL HDT-203000K-D14-DV-FSN 20 21 0.0 SPARE AFCI 20/1 17 A 18 30/2 DRYER 2500.0 BRUSHED NICKEL FINISH, POLYCARBONATE LENS NUVO 62-1036 0.0 SPARE AFCI 20/1 19 B 20 I 2500.0 0.0 SPACE 21 A 22 SPACE 0.0 0.0 SPACE 23 B 24 SPACE 0.0 MAIN LUGS B CELING SURFACE UNTED, 10"ROUND,BRUSHED NICKEL FNISH, POLYCARBONATE LENS 3000K 1200 120 ASL HDT-123000K-D10-0V-FSN 12 13 NUVO 62-1035 UNIT PANEL - UNIT 2 (REPLACE EXISTING) UNIT #2 VOLTAGE: 120/240V,1 PH,3 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND C CEILING FLUSH MOUNT ROUND,7"ROUND, 3000K 820 120 SATCO NWO 99331 14 14 TYPE: LOADCENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST NEW TOTAL FACTOR LOAD(VA) WHITE FINISH, DMMABLE. ASL SAS-7-WHITE-13.5-3000K-D7 ENCLOSURE: NEMA 1 FULL AC RATING: 10,000 A General Lighting&Outlets(3 W/SF) 0.0 3024.0 3024.0 ESSENTIAL SMT3K7-14-900W MOUNTING: FLUSH SERIES AC RATING: NONE Small Appliance&Laundry 0.0 1500.0 1500.0 DALS CFLEDR06-WH Electric Range 0.0 8000.0 8000.0 LfiON LCMPD7RWT30 BUSSING. MANUFACTURER'S STANDAR[SPECIAL PROVISIONS: Electric Clothes Dryer 0.0 5000.0 5000.0 n'❑ CONTINUOUS RATING: 100 A Misc.Fixed Appliances 0.0 2426.5 2426.5_ D CELING RESIDENTIAL GRADE RECESSED HOUSING, 3000K 600 120 HALO E7501CAT LT56 10 10 FULL AIC RATING: 10,000 A MASTER NAMEPLATE TOTAL 0.0 19950.5 19950.5 6"ROUND, IC RATED,WITH INTEGRATED LED WHITE C SERIES AIC RATING: NONE Demand Factor(First 10,000W) 1.00 10000.0 BAFFLE TRIM. VET GROUND BAR Demand Factor(Remainder) 0.40 39802 MAIN: LUGS ONLY LOCATION: BOTTOM SQUARED TYPE HOM Air Conditioning 0.0 0.0 0.0 1.00 0.0 E WALL SCONCE, 10"x 4.125"x 3.5", BRUSHED NICKEL 3000K 800 120 NUVO 62-317 10 10 REV ISSUED FOR DATE Electric Space Heating 0.0 0.0 0.0 0.40 0.0 25%Largest Motor 166.8FINISH WITH FROSTED ACRYLLIC LENS. TOTAL LOAD 0.0 19950.5 19950.5 14147.0 TOTAL AMPS 0.0 83.1 83.1 58.9 F BATHROOM VANITY,24"LONG, BRUSHED NICKEL 3000K 2000 120 ASL VBJ-19-3000K-L22-DV-FSN 26 27 CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER /BRANCH CIRCUIT CONN. FINISH&POLYCARBONATE LENS NW0 62-872 LOAD(VA) DESCRIPTION NOTE AMP/P NO ,(PHASE)._ NO AMP/P DESCRIPTION _4DTE LOAD(VA) 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 1 _ A 2 15/1 LTG-KITCHEN AFCI 0.0 1500.0 OUTLETS-KITCHEN GFCVAFCI 20/1 _ 3 8 4 15/1 OUTLET-BATHROOM GFCVAFCI 0.0 667.0 DISPOSAL GFCVAFCI 20/1 5 A 6 15/1 LTG&OUTLETS-LIVING ROOM AFCI 0.0 G EXTERIOR WALL MOUNT ENTRY LIGHT, 5000K 1800 120 NUVO 65-096 20 20 931.5 DISHWASHER GFCVAFCI 20/1 7 B 8 15/1 LTG&OUTLETS-UPSTAIRS NORTH AFCI 0.0 5.5"H X 5"W X 9"D,POLYCARBONATE HOUSING PLAN NORTH TRUE NORTH 4000.0 RANGE 50/29 A 10 15/1 LTG&OUTLETS-UPSTAIRS SOUTH AFCI 0.0 BRONZE COLOR,WET LOCATION RATED. 4000.0 I 11 B 12 15/1 OUTLETS-DOORBELL&COMM PANEL AFCI 0A 0.0 SPARE AFCI 15/1 _ 13 A 14 20/1 FURNACE AFCI 828.0 SCALE: 1/4"=1'-0"0.0 SPARE AFCI 15/1 15 _ B 16 20/1 _WASHER AFCI 1500.0 0 4' - - 0.0 SPARE AFCI 20/1 17 A 18 30/2 DRYER 2500.0 H BREEZEWAYWALLPACKLIGHT,8.5"Wx7.5"Hx 5000K 3300 120 NUVO 65-133(ADD PHOTOCELL) 27 27 0.0 SPARE AFCI 20/1 19 B 20 I 2500.0 5"D, POLYCARBONAGE HOUSING, BRONZE COLOR ANACORTES 0.0 SPACE _ 21 _ A 22 SPACE 0.0 WET LOCATION RATED,WITH INTEGRAL PHOTOCELL. 0.0 SPACE 23 B _ 24 SPACE 0.0 HOUSING MAIN LUGS AUTHORITY NOTES:1. SITE 1 1. CONTRACTOR& LIGHTING FIXTURE SUPPLIER SHALL VERFY DESCRIPTION,MOUNTING REQUIREMENTS,CATALOG NUMBERS, ETC.MATCH.ADVISE ENGNEER OF ANYCONFLICTS OR DISCREPANCES DURING BIDDING. ANACORTES HOUSING AUTHORITY ELECTRICAL p RISER DIAGRAM[]PANEL SCH.° 0 LTG FIXTURE SCH. PROJECT No: 1936 DRAWN BY: KL CHECKED BY: BD DATE ISSUED: 12/06/18 EG.01 ©p+o