Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File 3916 W6th Street
O,T C of CITY OF ANACORTES WASHINGTON 4c BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): Single Family Residence Located At: 3916 West 6th Street STREET&NUMBER Owner: Unmoor Development Constructed By: OWNER OR CONTRACTOR Bldg.Permit# COLI95-0140 Date Of Issue: 8-16-95 R3 Occ.Group: Use Zone: R2 Has Been Inspected And Occupancy Is Hereby Authorized, This $th Day Of November 19 95 AUTHORIZING ORFCI SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. FINAL INSPECTION CHECKLIST O.K. F.g Cent c0 Inspection Date: / /_t- 9 — Address: 39t(0 L,,FS-;- E;ri Permit No.(cy rCIS&.Uj4p Date: 8-1 (e cc Zone: 2). Owners Name: lU oc,r Owners Address: Occupancy Group: Consruction Type: Variances: Safety Glass: CA K Sewer Fee Paid: Hand Rails: 0 /< • Sewer Inspected: Guard Rails: ©. 1e. WSEC Compliance: Traps: oK , Attic Access: od( Weed Stove: p K. Smoke Detectors: p, �{, Water Pressure: 0. W , T&P Drain: cA K. House Numbers: K. Insulation Cert: Site Drainage: c.rf. Radon Test Kit: Curb Cut: ,enj<. Garage House Door: O-0'. Crawl Space Insul: e' k, Bedroom Windows: E>. K, Crawl Space Access: D, j, Water Heater Strap: 0. R!. Vapor Barrier: D.W. Air Gap: C5 Water MeterBox: 9g, Auto Garage Door: ©, 14• Outside Caulking: o K• Exterior Decks/Landings: C214, Exh. Duct/Dryer Vent Dampers: c K. EX�w PT e6N ! , 1 S c; we.t2 1 I 7 / 6 w�" 'bTh-- ; 3 9 - /2 - ys �� z a I g �6� fs et ' I RI 1 , , .I Pe. LAJ 6 37 COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : COM95-0140 I P.O. BOX 547 APPLIED: 08/16/95 ANACORTES, WA 98221 ISSUED: 08/16/95 (206) 293-1901 EXPIRES: 08/16/96 SITE ADDRESS: 3916 WEST 6TH ASSESSOR'S PARCEL NO. : 3809-313-007-0000 PROJECT DESCRIPTION: Construct new framed single family residence per approved plans. - OWNER — CONTRACTOR — LENDER WILMOOR DEVELOPMENT WILMOOR DEVELOPMENT 16981 REDMOND WAY 16981 REDMOND WAY REDMOND WA 98052 REDMOND WA 98052 206-885-2287 885-2287 WI LMOCI169KA — FEES TYPE OF WORK -NEW AREA (sf) VALU...$: 111577 Code Amount---- By- Date---- Receipt TYPE OF USE -SF LOT - 8250 REQUIRED SETBACKS---- ESPL $ -100.00 EF 08/16/95 4293 CENSUS CATEGORY -101 1ST FLR • 844 FRONT • 20 ft PLCK $ 300.95 EF 08/16/95 4293 ZONING 2ND FLR 963 SIDE(1)..: 5 ft PRMT $ 463.00 EF 08/16/95 4293 :RES LOW R2 BASEMENT • 0 SIDE(2)..: 10 ft PMEC $ 46.50 EF 08/16/95 4293 OCCUPANCY GROUP GAR/CARPORT...: 400 REAR • 20 ft PPLM $ 125.00 EF 08/16/95 4293 :R3 •? :? OTHER • 88 REQUIRED PARKING-- STBC $ 4.50 EF 08/16/95 4293 TYPE OF CONSTRUCTION TOTAL • 2 SEWR $ 3258.00 EF 08/16/95 4293 :5N :? •? :? : NUMBER OF UNITS • 1 ACCESSIBLE.: 0 1MPT $ 400.00 EF 08/16/95 4293 OCCUPANT LOAD STORIES • 2 COMPACT • 0 INSP $ 50.00 EF 08/16/95 4293 . 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0 FURN < 100K BTU: 1 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 4547.95 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 0 FURN - FLOOR...: 0 30-50 HP - 0 GAS WTR HEATERS: 1 — NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 1 VENT FANS • 0 AIR HANDLING UNITS-- FIRE LOG/LITE..: 1 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 3 HOODS • 0 WATER CLOSETS...: 3 WASHING MACHINES: 1 FLOOR DRAINS • 0 BATH TUBS . 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 1 SHOWERS • 0 LAUNDRY TRAYS...: 1 HOSE BIBBS • 2 DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0 --- LAVATORIES . 3 WASTE INTERCEPT.: 0 ADD'L FIXTURES..: 0 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws re Lating activities covered by this permit. _ $7Q Issued Appli t Owner's Signature 24 Hour Notice Required For All Inspections com_prmt, Rev: 11/04/93 COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : C0M95-0140 P.O. BOX 547 APPLIED: 08/16/95 ANACORTES, WA 98221 ISSUED: 08/16/95 (206) 293-1901 EXPIRES: 08/16/96 SITE ADDRESS: 3916 WEST 6TH ASSESSOR'S PARCEL NO. : 3809-313-007-0000 PROJECT DESCRIPTION: Construct new framed single family residence per approved plans. — OWNER — CONTRACTOR — LENDER WILMOOR DEVELOPMENT WILMOOR DEVELOPMENT is 16981 REDMOND WAY 16981 REDMOND WAY t REDMOND WA 98052 REDMOND WA 98052 7 206-885-2287 885-2287 WILMOCI169KA — FEES TYPE OF WORK -NEW AREA (sf) VALU...$: 111577 Code Amount---- By- Date---- Receipt TYPE OF USE •SF LOT - 8250 REQUIRED SETBACKS---- ESPL $ -100.00 EF 08/16/95 4293 CENSUS CATEGORY -101 1ST FLR • 844 FRONT • 20 ft PLCK $ 300.95 EF 08/16/95 4293 ZONING 2ND FLR • 963 SIDE(1)..: 5 ft PRMT $ 463.00 EF 08/16/95 4293 :RES LOW R2 BASEMENT 0 SIDE(2)..: 10 ft PMEC $ 46.50 EF 08/16/95 4293 OCCUPANCY GROUP GAR/CARPORT...: 400 REAR • 20 ft PPLM $ 125.00 EF 08/16/95 4293 :R3 •? •? OTHER • 88 REQUIRED PARKING-- STBC $ 4.50 EF 08/16/95 4293 TYPE OF CONSTRUCTION TOTAL 2 SEWR $ 3256.00 EF 08/16/95 4293 :5N :? :? :? : NUMBER OF UNITS • 1 ACCESSIBLE.: 0 IMPT $ 400.00 EF 08/16/95 4293 OCCUPANT LOAD STORIES - 2 COMPACT • 0 INSP $ 50.00 EF 08/16/95 4293 . 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0 FURN < 100K BTU: 1 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 4547.95 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 0 FURN - FLOOR...: 0 30-50 HP - 0 GAS WTR HEATERS: 1 — NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 1 VENT FANS • 0 AIR HANDLING UNITS-- FIRE LOG/LITE..: 1 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 3 HOODS • 0 WATER CLOSETS...: 3 WASHING MACHINES: 1 FLOOR DRAINS - 0 BATH TUBS - 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 1 SHOWERS • 0 LAUNDRY TRAYS...: 1 HOSE BIBBS • 2 DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0 LAVATORIES • 3 WASTE INTERCEPT.: 0 ADD,L FIXTURES..: 0 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws gulating activities covered by this permit. >s ued by Appli`sdn r Owner's Signature 24 Hour Notice Required For All Inspections com_prmt, Rev: 11/04/93 RESIDENCE FOR -,�_ ( - M r Pa of ` -HEAT LOSS LOCATION: Lot: ,CI Pam of LIS eA v, DESIGN TEMPERATURE DIFFERENCE: _C %.�� .• •CALCULATION FORM Plan or Model No. PISc. Dated ,;3,,{Heated Square Ft. a ADDED INSULA- HEATED SPACE T • TION ' R-VALUE bu.ber w...bee wwler Yt berso. w.nber e�.•:fr f MATERIAL SOURCE OF v,ct or sa. er +a. er ,.. .r ,.. er +.. ,+ ,o, t ONLY HEAT LOSS Ta.lf (m+ eo. er yin' ao, er vat, ao. :; %v,+t ao. .r Watt :: nr I van a.. er van m�,fa ran.,_ lin.r_ ten.rt. lea, test, linat. tabs Fa.ft. 1 tons lir.r, 1 I � GROSS WALLS v� ; '- - Gi / �� +/J/Qf ///�LESDOWS: a_wi '� �` I erl • (Single( L.Ir I I // LESS. WINDOWS: -- { /� looW I Table 1 i/ I ♦LXL �, LESS DOORS ,,,,, , • I I (Exterior) Ly/ O 1 NET WALLS : "re *Tabte t O.a NI a l..1s7` • INET WALLS: conernel r,.l. I0.91D / b J4Te/4; bout Snde 1 CEILING; -en,<o r [5^�1 • r I Irma boa '•1: Table l• jo6Si P /4, 1s 9 3I. ? -; 1 L 4, )O I CEILING: oeentinm ' �/ � T.wle S I 1 I' 1 i FLOOR._ ewer .fnne *Ink b ©.sty )Ag e7i.2_ 711j l } ! /Si� I 1 I 1 FLOOR. on' vn.fns.a .nb,.,..�Sa+,, :o Tabte 7 } ' i • IL GR: slob :na;ash/ding I I .4L. see;. .rl$s.fiw,l rt. T.sla I 6.y.� I ) I --iwCOFV10N:WALLS: Table y I I Sq I( Iriel, u. 0 5 Iwe0pMo4,CEILING: T,ble , I r COMMON FLOOR: dC ' 1 �y�lT` l 5 �wattiele unlit Lble 9 I I I 7 I. �+ ir/ INFILTRATI ON(c..rt 1 rant. Ic.O 278I '732. t795 7 t ! G� n ' i 1 ci ,.air e.anae/.e. I 7lj S I rTr ;r • ___ _INFILTer-rat Ice.rt. SINF baser-rat .eblf i WATT LOSS PER ROOM . e" 42657� 9 .4 � � %, �rf INSTALLED WATTAGE • J r{ 1 , Structure Heat Loss ;(SHL) = • Watts; 1 5, Estimated Duct or Piping Heat Loss = 1 2. Duct or Piping Insulation (inches or approx. SHL (I) x OHLM (3) x Fraction (4)= • Watts. s. R lu-vae . 6. Total Heat Loss (I plus 5) . . Watts. 3. Duct Heat Loss ilq kiplier (Table II) DHLM = 7. Total Installed Watts . Watts. 4. " ' - Fraction of Ductwork in Unheated Space. . „ ' • T Mobile Homes .- Use Table 12 and 13. WORKED BY irn 'a":�� DATE 8 /�3/iCil �61:42'2I"E IoN�Pccsf� ! uTiuTY �P�11<1�►�Id"f 1 Zoe pa5.6L. I- al 1 N. '! o� 10 11 J 1 3 I 1 Q o Mg - ' IG 140I G Pc& I • _ 1 t 0 CGk IVE4lA{� N • NI&r }z'21" . I P L o-r '7 Sr€Q,LI -16 Pu4c£ - 3 ci, Rs, ..J- Cn DATE: R{SfQS PERMI'1 NO: -- -, _ CITY OF ANACORTES PLUMBING AND MECHANICAL PERMIT 39/& SITE ADDRESS: ..,z.-_j,j ' --_ ----, ASSESSOR'8 NUMBER: LOT: %2_ BLOCK: OF: tc.EtL.,-.1� ?, .,- OWNERS NAME: Wilmoor Deve r-60116.H PHONE: 8115-2287 ----_- ADDRESS: 16981 Redmond Way, uptltiIS)nd . WA 98052 ---- ' I ; ' U:.' 3•!!!>ilY3.t£j!?3! ? 3'E?" '!n i':!?'i i' �".�13;'i:!''`:.,i i ii ..?!.°i`;.tji...?.> i'>"` P>x3::£3:Ti••e!'??tlr#iai5::.:i:)iiiibfr£;l;:l�:?j>ap�'£� ii£i£?i I ,3 .��) .�� � �`I. lI I� I.,�J, �. i lit L py: > 1'i;.il?3(1'#Ij;sfl;Ii;'j : iiPy ;£ !??..I a?�j 13 p,�>3 !!� 4,'���I? I :1?i,(.';(:.,!„£:I£ L •d% ;k ..:>..,1:``r?:lti?. uI .k-Lt . 6 it ii yin*.,£S y, "'.',.La^ ?. r!',',{?`{?•?3S4 ! ftl?i 3� .Y.t`8:�,?r.3�.�?3i,.�3,a:??i�':i3.uii, _�s:.�t3 :ls . ..iMt .k%iti'Li::.o:...un,'� ��.s+.?i�,'�'.� � i�niii: CONTRACTOR: pacific NW PluiuUHi9 CONTRACTOR: BARRON HEATING PHONE: 483-2585 PHONE: 676-1131 CONTRACTORS LIC. NO: CONTRACTORS LIC. NO: NOl TYPE OF FIXTURE OR ITEM NO TYPE OF EQUIPMENT 7 3_ WATER CLOSET 3.5 GEM III AIR COND. UNIT _-__ Al 2- BATHTUB L—----� __ -- _---- REFRIGERATION UNIT HP SHOWER 3.0 GPM BOILER HP Z ( DISHWASHER 3.0 GPM ( I FORCED AIT SYSTEM/ BTU/HP 3 3 LAVATORY 3.0 GPM (II ' FLOOR FURNACE BTU _— ( L KITCHEN SINK 3.0 GPM 1 WALL HEATER 2- ( _ CLOTHES WASHER 1 CLOTHES DRYER BTU URINAL 3.0 GEM __ VENTILIATION FAN Y DRINKING FOUNTIAN RANGE HOOD FLOOR SINK OR DRAIN AIR HAtMLING UNIT CFM _ - _ SLOP SINK i PRE-MANE. STOVE OR FIREPLACE _._ 4. WATER PIPING i OAS FIREPLACE BTU Ciji LAUNDRYAINK: ? 7 I GAS WATER HEATER / BTU OTHER(DESCRIBE) : GAS PIPING 1, Lo 2 Jks- e(BS OTHER(DESCRIBE) : _ 1 _ —____' _ 3‘-' ______ GAS: ) OIL: ELEC: OTHER: . NOTICE THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM PLUMBING AND MECIINIICAL CODES AND SHALL EXPIRE BY LIMITATION AND BECOME NULI. AND VOID IF PERMIT IS NOL MAIMED WITHIN 180 LAYS OF THIS APPLICATIONI. AY AFFIXING MY SIGNATURE 7 HEREBY CERTIFY THAT 1 All THE LEGAL, OWNER OF TOE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR NI AUTHORIZED) AGENT (IF' 711E OWNER. ALL PROVISIONS OF LAWS Nlt) ORDINANCES GOVERUPIG TUTS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT,INCLUDING CALLS FOR NISPECPG)lis. RECEIVED JUL 06 1gss SIGNATURE: DATE :FN NLDING DEPT 1 I DATE: 14 /0.6 PERMIT NO: CITY OF ANACORTES • BUILDING PERMIT APPLICATION 321�- SITE ADDRESS: -mmire5-7 , mot.. . p ^ ,/ ASSESSOR'S NUMBER: ._1(SG� —313— OG I—CSC 7� k ) '3/ I LOTS .� BLOCK OF 'cT-P�„�" n% ,ttt�4-"`lll OCR NEA:'..•i• . ••. .. :: . . .... • LENDER• CONTRACTOR°.:: NAME: NAME: NAME: Wilmoor Development Wilmoor Construction, In: . MAILING ADDRESS: MAILING ADDRESS: MAILING ADDRESS: 16981 Redmond Way 16981 Redmond Way CITY: STATE: ZIP: CITY: STATE: ZIP: CITY: STATE: ZIP: Redmond WA 98052 Redmond WA 98052 PHONE: PHONE: PHONE: LIC NO#: 206-885-2287 WILMOCI169KA CONTACT PERSON: Joe Wilson PHONE: 885-2287 FAX: 881-5538 : OCCUPANT USE l '',i Hi ,i RESIDENTIAL NON-RESIDENTIAL OTHER SINGLE FAMILY: / RETAIL: STORAGE: ___ MULTI-FAMILY: OFFICE: ASSEMBLY: __ APARTMENT: RESTAURANT: ACCESSORY: ___ CONDOMINUM: BANK: AUTOMOTIVE REPAIR: SENIOR HOUSING: MANUFACTURING: OTHER(SPECIFY) : OTHER(SPECIFY) : OTHER(SPECIFY) : DESCRIPTION OF WORK .. .: ' BUILDING: �14._,___) C0,45r. REPAIR: SHORELINE /WETLANDS Y N PLUMBING: GRADING & FILL: WATER ON / ADJ TO PROP Y N MECHANICAL: DEMOLITION: SOILS REPORT Y W SPA/HOT TUB: OTHER: SENSITIVE AREA Y N POOL: LATECOMMERS AGREEMENT Y N NEW CONSTRUCTION: ✓ FIRE HYDRANT<(250 FT) Y N ADDITION: • VARIANCE Y N ALTERATION: COVENANT Y N DESCRIBE WORK: A',--er.✓ 9SJcV7 S,zeC ha in/4 et- j( (lt=A;Ca GENERAL INFORMATION '.:::.:': . STREET SETBACK: 7� FT LOT AREA: RD. 'o SF CARPORT AREA: SF 1ST SIDE SETBACK: „o FT NO. OF DWELLINGS: / GARAGE AREA: 4490 SF 2ND SIDE SETBACK: 5 FT LOT COVERAGE: /33 7— SF NO. OF STORIES: SF REAR SETBACK: 2.40 c FT 1ST FLOOR AREA: a 147/ SF DECK AREA: 98 SF USE ZONE: 2ND FLOOR AREA: 94.2 SF MISC. : SF OCC. GROUP: 3RD FLOOT AREA: ff SF TYPE OF CONST: BASEMENT AREA: "0`— SF PROJECT VALUATION(LABOR AND MATERIALS COST) : //I/ } 7 7 NOTICE THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM BUILDING CODE, SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN ISO DAYS OF THIS APPLICATION, BY AFFIXING MY SIGNATURE I HERBY CERTIFY THAT I AM THE LEGAL OWNER or THE PROPERTY FOR WHICH ' THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, INCLUDING CATrF.bel no • INSPECTIONS. AAt���66rr���I JUL 0 6 1995 SIGNATURE : DATE : -BUILDING DEPT. : . , . . FOR OFFICE USE ONLY . ...:....:. .::::....: .... „": fiDD 2`TAITP�L i' It7F�RMAT Q 1 is i r r, is ,p r e Ni ar'3ii'i ki i „ I ' 'wPi,��wl,lr ria:rai 'i:�Quur up,�,!�,I fIPP ,Parp4 Poi�lupl'i '�rii ' hl. STEEP SLOPE: ENGINEERING REQUIRED: WETLAND: WAC 51 COMPLIANCE REQ: SHORELINE: SKYLINE APPROVAL: SOILS REPORT: CLEARIDGE APPROVAL: WATER METER SIZING: VISTA TWO APPROVAL: UNSTABLE SOIL: OTHER: PLANS REVIEWED BY: DATE: i:. :::COND ITIONS'::AND<'COMMENTS '? Gr P.ERMIT .'FEES PROJECT VALUATION INFORMATION FEES ESTIMATED VALUATION: ✓ BUILDING PERMIT: FIRST FLOOR: SfN(-/ 5�- 417 $S. ✓ PLUMBING PERMIT: SECOND FLOOR: 7b 54, I 5 L/6G 2 ✓ MECHANICAL PERMIT: THIRD FLOOR: ✓ PLAN REVIEW: GARAGE: 4f00" 9a.(p I ?LiU r/ SEWER FEE: DECK: GAS io �re- SEWER INSP FEE: MISC: RADON TEST KIT: III - 4.- IMPACT FEE: ,.-.-, ' ... • TOTAL VALUATION: • lJ�i .} • ✓ STATE CODE: MISC. FEES: DEPOSIT': :.: ' TOTAL:�:. . .. .: . : ...:::,..:� :�:�::�,.�:.:.:...: .... .,..,.: • AEPARTMENTAL,:.APPROVALS:. PLANNING DEPARTMENT APPROVAL: SEE ATTACHED PUBLIC WORKS DEPARTMENT APPROVAL: SEE ATTACHED FIRE DEPARTMENT APPROVAL: SEE ATTACHED SITE PLAN REVIEW: SEE ATTACHED