HomeMy WebLinkAboutPermit File 3819 W6th Street y
GY o CITY OF ANACORTES
WASHINGTON
9cnco
BUILDING DEPARTMENT
CERTIFICATE OF OCCUPANCY
This is to certify that the(Description of Building or Structure)
Sin le Family Residence
Located At: 3819 west 6th street
STREET&NUMBER
Owner: WI.baser t: eve.lonment
Constructed By: Wilcioor Develootnend
OWNER OR CSNTRACTOR
Bldg.Permit# Cloa't94-0154Date Of Issue: 09109 r`L.
Occ.Group: 11'"'3' _ Use Zone: F.L
Has Been Inspected And Occupancy Is Hereby Authorized,
This 2nd Day Of Tune 19 9 .
AUTHORIZING OFFICIAL
SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS.
DATE: AUGUST 10 , 1994 PERMIT NO:
CITY OF ANACORTES
PLUMBING AND MECHANICAL PERMIT
SITE ADDRESS: 3819 - 6th STREET WEST
ASSESSOR'S NUMBER:
r
LOT: 29 BLOCK: OF: STIPLING PT,ACF.
OWNERS NAME: Wilmoor Development PHONE: 885-2287
ADDRESS: 16981 Redmond Way, Redmond. WA 98052
CONTRACTOR: Pacific NW Plumbing CONTRACTOR: Lavine' s Heating
PHONE: 483-2585 PHONE: 791-6543
CONTRACTORS LIC. NO: CONTRACTORS LIC. NO:
NO TYPE OF FIXTURE OR ITEM NO TYPE OF EgUIPMENT
WATER CLOSET 3.5 GPM _ AIR COND. UNIT
2_ BATHTUB REFRIGERATION UNIT HP
SHOWER 3.0 GPM -- BOILER HP
( DISHWASHER 3.0 GPM _ i _FORCED AIT SYSTEM BTU/HP
.5 LAVATORY 3.0 GPM FLOOR FURNACE BTU
KITCHEN SINK 3.0 GPM _ WALL BEATER
1 CLOTHES WASHER CLOTHES DRYER BTU
URINAL 3.0 GPM VENTILIATION FAN
DRINKING FOUNTIAN RANGE HOOD
FLOOR SINK OR DRAIN AIR HANDLING UNIT CFM
SLOP SINK PRE-MANF. STOVE OR FIREPLACE
WATER PIPING 1 GAS FIREPLACE BTU
1 LAUNDRY SINK: j GAS WATER HEATER BTU
OTHER(DESCRIBE) : GAS PIPING
OTHER(DESCRIBE) :
GAS; OIL: ELEC: OTHER:
NOTICE
THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM PLUMBING AND
MECHANICAL CODES AND SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED
WITHIN 180 DAYS OF THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL
OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL
PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT,INCLUDING CALLS FOR INSPECTIONS.
SIGNATURE: DATE:
gletragrq
CdrnE AUGUST 10 , 1994 PERMIT NO.
CITY OF ANACORTES
BUILDING PERMIT APPLICATIlat`:
SITE ADDRESS: 3819 - 6th STREET WEST
ASSESSOR'S NUMBER: 5209 3AD-
LOTS 29 BLOCK OF STERLING PLACE
OWNER : :LENDER :cSTRACtOrtH.':;:,' •
NAME: NAME: NAME:
Wilmoor Development WA FEDERAL SAVINGS Wilmoor Construction, Ins.
MAILING ADDRESS: MAILING ADDRESS: MAILING ADDRESS:
16981 Redmond Way 16981 Redmond Way
CITY: STATE: ZIP: CITY: STATE: ZIP: CITY: STATE: ZIP:
Redmond WA 98052 Redmond WA 98052
PHONE: PHONE: PHONE: LIC NO#:
206-885-2287 293-5181 WILMOCI169KA
CONTACT PERSON: Joe Wilson PHONE: 885-2287 FAX: 881-5538
OCCUPANT USE : : .
RESIDENTIAL NON-RESIDENTIAL OTHER
SINGLE FAMILY: / RETAIL: STORAGE:
MULTI-FAMILY: OFFICE: ASSEMBLY:
APARTMENT: RESTAURANT: ACCESSORY:
CONDOMINUM: BANK: AUTOMOTIVE REPAIR:
SENIOR HOUSING: MANUFACTURING: OTHER(SPECIFY) :
OTHER(SPECIFY) : OTHER(SPECIFY)
'• . . . : : : : ,; .:.;. •-• i;
DESCRIPTION OF WOK(
BUILDING: Sr 2e.smae,4.-i-,ay_ REPAIR: SHORELINE /WETLANDS Y N
PLUMBING: GRADING & FILL: WATER ON / ADJ TO PROP Y N
MECHANICAL: DEMOLITION: SOILS REPORT Y N
SPA/HOT TUB: OTHER: SENSITIVE AREA Y N
POOL:
LATECOMMERS AGREEMENT Y N
NEW CONSTRUCTION: FIRE HYDRANT<(250 FT) Y N
ADDITION: VARIANCE Y N
ALTERATION: COVENANT Y N
DESCRIBE WORK:
GENERAL INFORI'dAtION
STREET SETBACK: FT LOT AREA: SF CARPORT AREA: SF
1ST SIDE SETBACK: 5 FT NO. OF DWELLINGS: GARAGE AREA: 1-) g SF
2ND SIDE SETBACK: lc) FT LOT COVERAGE: SF NO. OF STORIES: SF
REAR SETBACK: to FT 1ST FLOOR AREA: lob ( SF DECK AREA: SF
USE ZONE: 2ND FLOOR AREA: / 71) SF MI S C. : SF
OCC. GROUP: 3RD FLOOT AREA: SF
TYPE OF CONST: BASEMENT AREA: SF
PROJECT VALUATION(LABOR AND MATERIALS COST) : itk / /, ()On
NOTICE
THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM BUILDING CODE,
SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN 180 DAYS OF THIS
APPLICATION. BY AFFIXING MY SIGNATURE I HERBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PROPERTY FOR WHICH
THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCES
GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, INCLUDING CALLS FOR
INSPECTIONS.
SIGNATURE : DATE:
l
FOR OFFICE USE ONLY
ADDI Yya� � ;:::.:;;>;;::
!i.::�y"n1tL..:
..................+J:.....":o::?r.:::ry.,.:......::....:.J" ...:.:..[:::.. nlimmamgin
y::! 'iv;;'f :ffw
STEEP SLOPE: _ ENGINEERING REQUIRED:
WETLAND: _ WAC 51 COMPLIANCE REQ:
SHORELINE: _ SKYLINE APPROVAL:
SOILS REPORT: _ CLEARIDGE APPROVAL:
WATER METER SIZING: _ VISTA TWO APPROVAL:
UNSTABLE SOIL: �- OTHER:
PLANS REVIEWED BY: DATE:
NBITIONSi':AND[>COMMENTS'.: :';. :::'r:!t:: :'_';.ss?';'a-a:".7:.`'i :' ':':['.(sr .:".::
::.[J .:..:.' '":.::.... ': .. °: '. :':> 'FERMITC.:k'EES..:;;i ..:,'.1siti9: :'i::>i :i: ::.: : :.: ::>;:3f;:"::::: 'S`:.:':_;:
PROJECT VALUATION INFORMATION FEES
ESTIMATED VALUATION: BUILDING PERMIT:
FIRST FLOOR: 100/ PLUMBING PERMIT:
SECOND FLOOR: 770 e' qa,,>,.ri) p( MECHANICAL PERMIT:
THIRD FLOOR: y PLAN REVIEW:
GARAGE: 41/1 ,S000 t< SEWER FEE:
DECK: K SEWER INSP FEE:
MISC:
RADON TEST KIT:
ne IMPACT. . ..: .: ... .. ... .. :
[TOTAL':;VALUATIONi::'}:' . .
'. A45' t STATE CODE:
.... ..r".�:t;::R/:r:t~.+.:+...: MISC. FEES:
:SUB`:.TOTAill.:::::::;:.:::i;!si ;:r.:[:f:: ;;. . : ::.::
DEPOSIT '. ' ar. .:
,.....::. ..:" :
;TOtAL:.:. ' c::::: r._. .;;::..:.
;'' DEPARTMENTAL':AP
...[::;.:':.:...:;. :. PROVALSs:l; :`:J_:;.:, .a. ::;, ..::.z,:; <'' ::...... :: ..
PLANNING DEPARTMENT APPROVAL: SEE ATTACHED
PUBLIC WORKS DEPARTMENT APPROVAL: SEE ATTACHED
FIRE DEPARTMENT APPROVAL: SEE ATTACHED
SITE PLAN REVIEW: SEE ATTACHED
COMBINATION PERMIT
CITY OF ANACORTES PERMIT NO. : COM94-0154
P.O. BOX 547 APPLIED: 09/07/94
ANACORTES, WA 98221 ISSUED: 09/09/94
(206) 293-1901 EXPIRES: 09/09/95
SITE ADDRESS: 3819 WEST 6TH
ASSESSOR' S PARCEL NO. : 3809-312-022-0000
PROJECT DESCRIPTION: New single family
— OWNER — CONTRACTOR — LENDER
WILMOOR DEVELOPMENT WILMOOR DEVELOPMENT
16981 REDMOND WAY 16981 REDMOND WAY
REDMOND WA 98052 REDMOND WA 98052
885-2287 885-2287
WILM0C1169KA
— FEES
TYPE OF WORK •NEW AREA (sf) VALU...$: 101000 Code Amount---- By- Date---- Receipt
TYPE OF USE •SF LOT • 0 REQUIRED SETBACKS---- ESPL $ -100.00 MD 09/09/94 2943
CENSUS CATEGORY •101 1ST FLR • 1001 FRONT • 20 ft PLCK $ 283.08 MD 09/09/94 2943
ZONING 2ND FLR • 770 SIDE(1)..: 5 ft PRMT $ 435.50 MD 09/09/94 2943
:RL BASEMENT 0 SIDE(2)..: 10 ft PMEC $ 66.50 MD 09/09/94 2943
OCCUPANCY GROUP GAR/CARPORT...: 0 REAR • 20 ft PPLM $ 111.00 MD 09/09/94 2943
:R3 :? •? •? OTHER • 0 REQUIRED PARKING-- STBC $ 4.50 MD 09/09/94 2943
TYPE OF CONSTRUCTION TOTAL • 0 SEWR $ 3121.00 MD 09/09/94 2943
:5N :? •? :? : NUMBER OF UNITS • 0 ACCESSIBLE.: 0 IMPT $ 400.00 MD 09/09/94 2943
OCCUPANT LOAD STORIES • 0 COMPACT • 0 MISC $ 20.00 MD 09/09/94 2943
0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf INSP $ 50.00 MD 09/09/94 2943
FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0
:/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0
FURN < 100K BTU: 1 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 4391.58
FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 1 ,
FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 1 — NOTES
UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 0
VENT FANS • 3 AIR HANDLING UNITS-- FIRE LOG/LITE..: 1
VENT SYSTEMS...: 0 <= 10000 cfm.: 0 W00DSTOVES • 0
VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0
EVAP COOLERS...: 0 GAS OUTLETS • 1
HOODS • 1
WATER CLOSETS...: 3 WASHING MACHINES: 1 FLOOR DRAINS • 0
BATH TUBS • 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 0
SHOWERS • 0 LAUNDRY TRAYS...: 0 HOSE BIBBS • 2
DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0
LAVATORIES • 3 WASTE INTERCEPT.: 0 ADD'L FIXTURES..: 0
KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0
I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all
ordinances and laws regulating activities covered by this permit.
Issued by A plica or Owner' s Signature
24 Hour Notice Required or All Inspections
com_prmt, Rev: 11/04/93
WATER METER SIZING
SITE ADDRESS : SS)Q 1KC_3Z31 6`
Owners Name : 63.dr-Dor Ce.240 ^r\-Qf --
Mailing Address : ) s9e)1 rr5D -61A3
Legal Description:
Lot: j Block: Addition: - 9eLr P)Qco
Assessors Account Number: 11
(Office Use Only)
Residential: No. of units: /
Commercial:
Meter Size: 33/41 t // cT
pi
Service Size: 1
Signature: Date: CI ' —ct
OVER 1" METER
GPM:
FLOW/HYDRAULICS: MIN: MAX:
RESIDENTIAL: COMMERCIAL:
IRRIGATION: MAX ZONE GPM:
MIN ZONE GPM:
************************************************************
INSTALLATION FORM NUMBER: DATE:
- I
S
s+-confn LX t ( G
7 i
1
J
/ /
ap•
-5 ' dr<47
4r k s; ,tl • 1/
PL
FINAL INSPECTION CHECKLIST
Inspection Date:
Address: 3 q W C¢
Permit No. Date: Zone:
Owners Name: W.LLY _
Owners Address:
Occupancy Group: R -?� Consruction Type: '
Variances: Safety Glass: pi--
Sewer Fee Paid: Di- Hand Rails: d H
Sewer Inspected: Ot- Guard Rails: Ok-
WSEC Compliance: Oh Traps: O r
Attic Access: h 1J nd Stove:
Smoke Detectors: ��^ Water Pressure: S'y
T&P Drain: 01^ House Numbers: pF- r
Insulation Cert: Qh Site Drainage: ®h
Radon Test Kit: 3- 1-a Curb Cut: 0-
Garage House Door: OV^ Crawl Space Insul: ey--
Bedroom Windows: Crawl Space Access: OI-
Water Heater Strap: bi- Vapor Barrier: Oh
D.W. Air Gap: 0h Water MeterBox: 01''
Auto Garage Door: Outside Caulking: DI
-
)(Exterior Decks/Landings:
Exh. Duct/Dryer Vent Dampers: () {-
INSULATION CERTIFICAT 88
WILM A CONSTRUCTION, INC. 3819 WEST 6TH S
16981 REDMOND WAY
REDMOND, WA. 98052 LOT R 29 STERLING PLACE
2 STORY
Tyne of Material Manufacturer Thickness 5q Ft Covered R Value Width s Bags Wt/Baq
AIR SEAL
44"CURRUGATED CARDBOARD BAFFLES @ 50 PKSNOT APPLICABLE 46.00
HBR BACKER ROD 3/8` NOT APPLICABLE
Total Sq Ft Installed: 46.00
ATTIC BLOW
INSUL-SAFE III BLOWING WOOL CERTAIN-TEEDCERTAINTEED 12.50 580.00 30 11.00 35.00
Total Sq Ft Installed: 580.00
WRAP WATER PIPES
R-8 UNFACED CERTAINTEED CERTAINTEED 2.50 70.00 8
7/8" ID 6' FOAM PIPE WRAP @ 282 PIECENOT APPLICABLE 12.00
Total Sq Ft Installed: 82.000
EXTERIOR WALLS
CERTAINTEED 20.00
R-19 UNFACED OWENS-CORNING OWENS-CORNING 6.25 1378.00 19
Total Sq Ft Installed: 1348.00
KNEEWALLS
R-19 KRAFT OWENS-CORNING OWENS-CORNING 6.25 283.00 19
Total Sq Ft Installed: 283.00
RIM JOISTS
R-19 KRAFT OWENS-CORNING OWENS-CORNING 6.25 30.00 19
Total Sq Ft Installed: 30.00
FLAT CEILING-BATTS
R-30 UNFACED CERTAINTEED CERTAINTEED 10.00 368.00 30
Total Sq Ft Installed: 368.00
SLOPED CEILING
R-30 UNFACED CERTAINTEED CERTAINTEED 10.00 352.00 30
Total Sq Ft Installed: 352.00
GARAGE CEILING UNDERHEAT F
R-19 UNFACED OWENS-CORNING OWENS-CORNING 6.25 330.00 19
Total Sq Ft Installed: 330.00
CANTILEVER FLOURS
R-19 UNFACED CERTAINTEED CERTAINTEED 6.25 50.00 19
Total Sq Ft Installed: 50.00
UNDERFLOOR
R-19 UNFACED CERTAINTEED CERTAINTEED 6.25 1018.00 19
Total Sq Ft Installed: 1018.00
Remarks: