Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0163 3929 Rock Ridge Parkway 1 C} City of Anacortes Invoice/Permit#: BLD-2021-0163 904 6th Street Applied date: 03/02/2021 P.O.Box 547 Issue date: 03/02/2021 _� t►�: Anacortes, WA 98221-0547 Expire date: 08/29/2022 (360) 293-1901 Job Address: 3929 ROCK RIDGE PKWY Permit Type: PV Solar Permit ANACORTES WA 98221 Project: APN: Remarks: INSTALL RACKING FOR ROOF MOUNTED SOLAR PV SYSTEM. Owner: MICHAEL&VICKIE HAMLETT Contractor: ECOTECH SOLAR Address: 994 CLERMONT DR Address: 1331 MEADOR AVE SUITE 103 RICHLAND WA 99352-9507 BELLINGHAM WA 98229 Phone: Phone: (360)318-7646 License#: General Information: Fees: Building Valuation 2005 Building Permit Fee 83.25 Plan Review Fee 54.11 State Building Code Fee Resi 6.50 Total Calculated: 143.86 Deposits/Receipts: 0.00 Total Due: 143.86 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. ?�- SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY �OOR CODE c tc,� 1� Y O {e .L.- Aphk,et, .4. s `Y 1t1 > 2, 0 FIELO�rt5e� Minimum eighteen inches unobstructed pathway shall be maintained along each side of any ‘111., horizontal ridge per IFC 1204.2.1 Not applicable if roof pitch is 2:12 or less. i _ CITY OF ANACORTES PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED F2O,C,�OQ5Q� MPLIANCE PERMIT#: DLL) 1 U 5 ADDRESS: 3929 Rock Rid e APPROVED BY: ILA,/ v SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT BE ALTERED WITHOUT AUTHORIZA ON. 4°R CODS CO �A w4 1� Y O c, 7 sr- to FIELD IN$� 0w I • AO 41011 3929 Rock Ridgerkwy L r„„,,,„144012%.... ii 1.-.5.....— "ea r 0 _ - - . IN _ IN t illii. ap ow, _ N _ 4 , •ilio 4114- Minimum eighteen inches unobstructed pathway 1 ilk ' ' — 4EL . — "" 5riner' 1.41r-rii,"011111hbami shall be maintained along each side of any horizontal ridge per IFC 1204.2.1 T , "lip t r ea' - . ' Not applicable if roof 41 • pitch is 2:12 or less. I ;0-. , .., 41P i . PPP' ilO _ .,///111017.48818011/11‘44116, . ,ad 'ir 1 4 .. st. gi IMP .... .4. 411". : d...._ . ill.11110.1141116 r '. -.--- 41I la It; frit 116 iiii M .err FOR CODE co w�'` 1 TY d1/44{e �� 9n As RCp .,z po City of Anacortes Photovoltaic System Permit r0 F/ELn +,co" Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic (PV) systems, including roof top arrays, ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor & Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code (Current Edition) International Fire Code (Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot, with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE: The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review. FOR CODE co 44 1TY 00{• Alphk,?, 9n 4, 1891 As roFIELD'v To Be Completed By the Applicant Project Address: 3929 Rock Ridge Parkway Project Applicant: Ecotech Energy Systems LLC DBA Ecotech Solar Applicant Email: info@ecotechsolar.com Phone No.:360-318-7646 Site Owner Name: Ross Hamlett & Vickie Capps PV System Description:8.71kW roof mounted solar electric system Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or x ❑ town home. 2. PV System is designed for rooftop of house in general compliance with applicable g ❑ codes. 3. Mounting system is engineered and designed for PV. X ❑ 4. Rooftop is made from light weight material such as shingles. X ❑ 5. PV system will be permitted and pre-approved by Labor& Industries Electrical X ❑ division. 6. To address uplift, panel are mounted no higher than 18"above the surface of the I ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings, race ways,and all other X ❑ appurtenances weight no more than one of the following. IF Yes, indicate which: o No more than three and one half(3.5 pounds per square foot(PSF) o Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF o Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. X ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to ❑ pitched roofs). Comments: IN By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑Yes ❑ No �Op[Z CODE Co A tcw�' 11Y O -e rri 7111111011 `r, 4, 1891 IRON RI DGE Engineering Design Guide Overview %4COR eye' roFin.nt-s Assembled Views I I 4 4 I F 1 f. - , 0—_• I . • 1 1 ....J.- f S Y I - I 1 . I I .�. a - I r _- T I— J I , A. • : -+ 4 'mama - - - - y .,--T I I■IIIII . ' - MIMI 1■111111H11 i SI / i■IIni It1111111111'• _ t :T i'',f' , ..,,HV111+ ;t . I , 1 11■11■11M I1111111111 ' - . A. •\ Flush Mounted I i I . I I I I I I ' , i \• . • '1 , .r r 1 - 1 5 -, I I I I I I I ! - I -t `] I *Sr - - +ii saw : . . . . i I, . . . : . • . -• . ♦ ♦ ♦ . } '• ♦ .: . • • • - -+--4 - , ♦ • • , • ♦ • • T 4— -• • - + • • 11{'III��I --i } t • Y' •� Tilt Mounted For a complete 360 degree interactive roof mounting viewing environment,go to:ironridge.com/products/roofmounting/360view. support@ I ironridge.com I (800)227-9523 Page 2 2015 v1.73 FOR CODE co 446 � 9n M UMW `nG�7'7Y� 1891 '�e IRONRIDGE Engineering Design Guide System Parts , C� OR �r0 FIELD Xv"- XR1000 Rail XR1000 is a heavyweight among solar mounting rails,built to handle extreme climates and spans 12 feet or more for commercial applications. Property Value 1114 Material 6000 Series Aluminum Finish Clear Anodized Beam Height 3.00" ilpierior.,-Illill Weight/Linear Foot 0.945 Lbs Total Cross-Sectional Area 0.807 In2 Section Modulus(X-axis) 0.530 In3 Moment of Inertia(X-axis) 0.843 In4 Moment of Inertia(Y-axis) 0.182 In4 Torsional Constant 0.436 In3 Polar Moment of Inertia 0.3299 In4 r- XR100 Rail XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions,while also maximizing spans. Property Value 1111 Material 6000 Series Aluminum Finish Clear&Black Anodized Beam Height 2.44" Weight/Linear Foot 0.68 Lbs Total Cross-Sectional Area 0.582 In2 Section Modulus(X-axis) 0.297 In3 +............ammuswasemnimmaimmuk Moment of Inertia(X-axis) 0.390 In4 Moment of Inertia(Y-axis) 0.085 In4 Torsional Constant 0.214 In3 Polar Moment of Inertia 0.126 In4 XR10 Rail XR10 is a low-profile mounting rail, perfectly matched to regions with light snow. It achieves 6 foot spans,while staying light and economical. Property Value Material 6000 Series Aluminum Finish Clear&Black Anodized i Beam Height 1.75" Weight/Linear Foot 0.436 Lbs Total Cross-Sectional Area 0.363 In2 -immiliftemnienniumuniminumminumillil Section Modulus(X-axis) 0.136 In3 Moment of Inertia(X-axis) 0.124 In4 Moment of Inertia(Y-axis) 0.032 In4 Torsional Constant 0.076 In3 Polar Moment of Inertia 0.033 In4 support@ I ironridge.com 1 (800)227-9523 Page 5 2015 v1.73 FOR CODE co 1Y {e �� 9n nG�7+4 1891 �e IRON RI DGE Engineering Design Guide System Parts COR °FIELI)11.4�e\ Internal Splice IronRidge Rails are easy to extend with our patent-pending Internal Splices. Property Value Material 6000 Series Aluminum Finish Mill Length 12" 1 Hardware 2 SS Self-tapping Screws End Clamp IronRidge End Clamps secure PV modules to XR Rails using the top slot,independent upon the module's mounting holes. Property Value Material 5000&6000 Series Aluminum Finish Mill&Black Height Varies depending on Module fit. Width 1.5" Depth 1.5" Weight 0.05 Lbs Hardware '"-20 SS Nut and Bolt Mid Clamp IronRidge Mid Clamps secure PV modules to the rail when there are multiple modules in a row. 4 Property Value Material 5000 Series Aluminum 4 Finish Mill&Black 4* Spacing between Modules Y" Width 1" Depth 1.5" Weight 0.05 Lbs Hardware 1/4"-20 SS Nut and Bolt Grounding Mid Clamp Grounding Mid Clamps pierce through anodized coatings to ground array,being ETL listed to UL 2703. Property Value Material 304 Stainless Steel Finish Mill&Black Spacing between Modules IA" Width 1" Depth 1.2" Weight 0.08 Lbs Hardware .4"-20 SS Nut and Bolt support@ I ironridge.com I (800)227-9523 Page 6 2015 v1.73 FOR CODE co 446 AW 9n rn `-f 4" 1891 ' ., I RON RI DGE Engineering Design Guide Overview fro Fri:t.1)trl`-`\ Assembly CAD Details Download AutoCAD File I Download PDF - -VARIES I I I I I I I I I I I I I I I I I I I I I I I I I I Mid Clamp I I I I I I I I I I I I I I TI 1 1 1 1 1 1 1 1 1 1 1 1 Hi 1 1 1 1 I I I I I I I I I I I I 1 1 1 1 410I 11iI1 1111 1 1111Iw 1 1 1 1 1 E /A I I I I Detail A-Mid Clamp to Rail-Plan 1 1 1 1 1 I 1 —SLOPE 3"=1'-0" Ill I l l I l l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Typical Flush Mount Array-Plan View 1/2"=1'-0" End Clamp L-Foot 4 I' `Aluminum StantlaR Existing Roof Shuduree\\\`Membrane/Insulation Section-Flush Mount-Flat Roof Detail B-End Clamp to Rail-Plan 3/4"=1'-0" 3"=1'-0" XR Rail Rear Tilt Leg(Length Vanes) 11 Steel StandoffN :i riXalra WAVA Mid Clamp // Solar Panel Exisgig Roof Shuclure Membranellnsulabon Section-Tilt Mount-Flat Roof ` L-Foot 3/4"=1'-0" -��• A.M1 Mid Clamp End Clamp XR Rail • Flashing AIM Existing Roof Structure NIP Detail C-Typical Roof Connection 3"=1'-0" Detail D-Mid Clamp to Rail-Elevation Detail E-End Clamp to Rail-Elev. — XR Rao — VARIES — C fD fE L-Foot I+ m f CS mf g u u u u u Exlshng Roof Structure VARIES Exishn8 Roof Structure Section-Flush Mount-Sloped Roof 3/4"=1'-0" Typical Flush Mount Array-Elevation 3/4"=1'-0" support@ I ironridge.com I (800)227-9523 Page 4 2015 v1.73 FOR CODE co w�w 1 T Y O <> eftaloo , p, E 1891 ec `C a Residential Building Permit Application •rOFIELI)`1.4Se� City of Anacortes Building Department P.O. Box 547 Anacortes, WA 98221 Street Address: 904 6th Street Phone: (360) 293-1901 Fax: (360) 293-1938 SITE ADDRESS:3929 Rock Ridge Parkway CONTRACTOR Igl Applicant PROJECT DESCRIPTION Name Ecotech Solar Address 1331 Meador Ave, Ste 103 City/State/Zip Bellingham, WA 98229 Phone 360-318-7646 FAX - Racking for roof mounted solar electric system State License#602-441-974 Exp 10.31.21 PARCEL NUMBER City of Anacortes Business License:X Yes ❑No P 133959 PROPERTY OWNER ❑Applicant LEGAL DESCRIPTION Name Ross Hamlett &Vickie Capps (0.2202 RECORDED ON NOVEMBER 6 LOT 12,PLAT OF 00K RIDGE N ER AUDITORS FILE AS PER PLAT NO.201711060065,RECORDS OF SKAGIT COUNTY,WASHINGTON. Address 994 Clermont Dr City/State/Zip Richland, WA 99352 PROJECT VALUATION Phone 509-942-9292 FAX _ $2005.00 Number of Dwelling Units E-Mail Address mrhamlet@icloud.com, Number of Stories vlcapps@icloud.com _ Building Area: ❑Architect❑Designer ❑Engineer❑ Applicant 1st Floor s.f. 2nd Floor s.f. Name 3`d Floor s.f. Basement s.f. Address Garage_ s.f. Carport s.f. City/State/Zip Deck s.f. Lot Area s.f. Phone FAX E-mail Address CONTACT ❑Applicant LENDER LENDER INFORMATION MUST BE PROVIDED FOR PROJECTS OVER$5,000 Name Libby Chartier- Ecotech Solar IN VALUATION PER RCW. Address see applicant above Name City/State/Zip Address Phone FAX City/State/Zip E-mail Address Phone No. CONTINUED ON THE BACK `JF(:)it. CODE w4 c.1TY O 0{• � 9n 'Y , At,. 1891 �w `� R C O e Residential Mechanical Fixtures �r0 FfELO Fuel Type ❑ Natural Gas ❑x Electric ❑ Wood ❑ Propane Gas ❑ Other Type of Equipment Number of Type of Equipment Number of Fixtures Fixtures Furnace<=100K BTU Clothes Dryer Boilers/AC/Heat Pump Gas Water Heater Gas Outlets Gas Fireplace Ventilation Fans Fireplace Insert Stove,Appliance Other Units Range Hood PV Array X Residential Plumbing Fixtures Type of Fixture Number of Type of Fixture Number of Fixtures Fixtures Toilet Clothes Washer Bathtub Electric Water Heater Shower Utility Sink Dishwasher Hose Bibb Hand Sink Water Piping Kitchen Sink w/Disposal Additional Fixtures I HEREBY ACKNOWLEDGE IF HAVE READ THIS PERMIT APPLICANT AND STATE THE INFORMATION IS CORRECT,AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING ACITIVIES COVERED BY THIS PERMIT APPLICATION. WITH THIS PERMIT ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT WASHINGTON STATE CONTRACTORS LICENSE AND A CITY BUSINESS LICENSE. STOP WORK ORDERS WILL BE ISSUED ON JOB SITES WHERE CONTRACTORS/SUBCONTRACTORS ARE WORKING WITHOUT PROPER LICENSE. 3/2/2021 APP A T'S SIGNATURE DATE Last Updated Nov.9,2012 FOR CODE co 4�O 't ZR: 4i�ge Parkway (#741434) I I ,�W .• -. P. 9t 28357 INDUSTRIAL BLVD., HAYWARD,CA 94545 Ry n et•'rs l A 1 7041143 K.) 3929 Rockridge Parkway Date 03/02/2021 ��� `��LGiifts..•��`c 3929 Rockridge Parkway,Anacortes, WA 98221 Total modules 26 &ile�s Hanwha Q.Cells: Q.PEAK DUO BLK-G6+ 335 (32mm) Total watts 8,710 Dimensions 68.5"x 40.55" x 1.26" (1740.0mm x 1030.0mm x 32.0mm) Attachments 32 ASCE 7-10 System Weight Load Assumptions Total system weight 1,332.8 lbs Wind exposure B Weight/attachment 41.6 lbs Wind speed 110 mph Racking weight 191.9 lbs Ground snow load 15 psf Distributed weight 2.6 psf Attachment spacing portrait 6.0' Roof Information Roof material Metal Building height 30 ft Roof attachment L-Foot Only Roof slope 9 ° Attachment hardware Square Risk category II Span Details XR100 - Portrait Reaction Forces XR100 - Portrait Zone Down Uplift Lateral Zone Max span Max cantilever (Ibs) (Ibs) (Ibs) 1 8' 5" 3' 4" 1 354 135 54 2 8' 5" 3' 4" 2 354 281 54 3 8' 1" 3' 3" 3 354 450 54 Last updated by Libby Chartier on 03/02/21 12:52 PM Page 1 of 4 FOR CODE Cp -O 't ZR: 4i9e Parkway (#741434) I I ,' .• -. P. 7i 28357 INDUSTRIAL BLVD., HAYWARD,CA 94545 M nn - io- 1 (1•„ 4. - fo', "� } Roof Section Weights Roof Section (all segments) ''0 . Po:. e, Total weight: 1,332.8 lbs Provided rail: 230' [14 x 14', 2 x 17'] �r0FI LO ' Portrait orientation Weight/attachment: 41.6 lbs Attachments: 32 Graphical entry Total Area: 509.8 sq ft Splices: 8 Distributed weight: 2.6 psf Clamps: 44 Diagram T NM N 11 I 51' 2" 1 Segments Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 3 10' 4" 2' 2" None 28' [2 x 14'] 4 0 4 5 17' 2" 2' 7" None 56' [4 x 141 6 2 8 Row segment totals (x 2) -> 112' [8 x 14'] 12 4 16 13 44' 6" 1' 3" None 90' [4 x 14', 2 x 171 16 4 24 Splice Details { r I I — I Last updated by Libby Chartier on 03/02/21 12:52 PM Page 2 of 4 FOR CODE Cp ," 't ZR: 4Vvle, ,9e Parkway (#741434) I I ,�W •' -• A �7� 28357 INDUSTRIAL BLVD., HAYWARD,CA 94545 M iiiiiiiy• • -ta 74" 1891 Aye N Z C'TrOFIE T. W FR(MODULE PV MODULE FRAME �_ RAIL # JIM. �C T- M— CAMO CAMO ...-------/I Mir RAIL CAMO End Clamp, Plan CAMO End Clamp, Front Grounding Diagram 0< 0 tO ,= = =0 TO � o � 1 .O< 101 O- -FM - -O Or 0- mo< 0 1011 FM 0 101 ov i I i 6 co 0, OUFO Clamp • Grounding Lug * Fault Current Ground Path I Min 10 AWG Copper Wire * Bonded Splice (Rail Connection) *Grounding Lugs and Wire are not required in systems using Enphase microinverters. Last updated by Libby Chartier on 03/02/21 12:52 PM Page 3 of 4 FOR CODE CO TWO ' j-R: 4i�e Parkway (#741434) •' -. AvIe, 7 28357 INDUSTRIAL BLVD., HAYWARD,CA 94545 iLdigioija M to=als nG7(� 1891 wS I ? .• v" Spares _ Total Qty sWiplices XR-100-204B 0 2 XR100,Rail 204"(17 Feet)Black XR-100-168B 0 14 XR100,Rail 168"(14 Feet)Black XR100-BOSS-01-M1 Bonded Splice,XR100 0 8 Clamps&Grounding UFO-C L-01-B 1 0 44 Universal Module Clamp,Black CAMO-01-M1 0 16 Hidden End Cam(universal clamp) XR-LUG-03-A1 Grounding Lug,Low Profile 0 4 Attachments LFT-03-B1 0 32 Slotted L-Foot,Black BHW-SQ-02-A1 0 32 Square-Bolt Bonding Hardware Last updated by Libby Chartier on 03/02/21 12:52 PM Page 4 of 4