Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0572 607 R Avenue (2)City of Anacortes 904 6th Street P.O.Box 547 Anacortes, WA 98221-0547 (360) 293-1901 Job Address: 607 R AVE ANACORTES WA 98221 Invoice/Permit #: Applied date Issue date Expire date BLD-2020-0572 09/24/2020 10/01 /2020 04/01 /2022 Permit Type: Commercial Alteration/Repair Permit Project: Remarks: INSTALL PREFABRICATED RESTROOM ON NORTH END OF PROPERTY, _ 06��� Owner: CITY OF ANACORTES Contractor: TBD (� Address: PO BOX 547 Address: ANACORTES WA 98221-0547 Phone: (360) 293-1901 Phone: License #: General Information: Building Valuation 350000 New or Replaced Hard Surface 1332 1st Floor Square Footage 520 # of Wall Heaters 1 # of Gas Water Heaters <= 100k 1 # of Drinking Fountains 1 # of Hose Bibs 1 # of Kitchen Sinks 1 # of Hand Sinks 2 # of utility Sinks 1 # of Floor Sinks 5 # of Urinals 1 # of Ventilation Fans 2 # of Water Closets (Toilets) 3 Fees: Building Permit Fee Plan Review Fee Mechanical Permit Fees Plumbing Permit Fee State Building Code Fee Comm Stormwater Review Total Calculated: Deposits/Receipts: Total Due: 2,393.75 1,555.94 67.50 125.00 25.00 106.56 4,273.75 0.00 4,273.75 permits and Insrp -BLD-�tth20-0F12 e 2h02IP The Issuance o granting o is permit s a not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of t���i@�,-'�4���t��ibr f�®€�F�f�g� 8r1 e�7�rr� order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or tang ��j i®pax( iit Yfy r Etcd to allow construct:.,, ccti✓l;y d ri„y any polio~ of time when such construction is prohibited or rest,,cted ty state c. r r r I io r or decision of the Governor or this State, tnis permit shall not authorize sucn work anc shah not oc � ��.%!y-,SiTj 8*Prj1RR9t ti�Iil �y err `4ii t - va i e bui Ing o Ici I is au orized b prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jCtrrA§SiMit§rk-W%W9 other ordin4nd6�bf "E)xecutive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of Mpa pgnT(kqhtbuilding offi tq al -js authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, i�tr �t� Or2r�{#� information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or ecisiton o the overnor. This permit becomes null and void if work or construction authorized is not commenced 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and expnedWt application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED � � D- 20�.0 - � �7 � 1G, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT IAL & MULQD��AMILY BUILDING PERMIT APPLICATION Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 PLEASE REFER TO THE COMMERCL4L &MULTI-FAMILYBUILDING PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT AI�I➢RESS (Str t, Suite #): PARCEL(S) #: p 130892 " R Ave, Anacortes, WA 98221 Subdivision/Lot #: PROJECT VALUATION: $ 350,000 APPLICANT: Dustin South Phone: 360-299-1948 Address (Street, City, State, Zip): Email Address: PO $ox 547, Anacortes WA 98221 dustins@cityofanacortes.org PROPERTY OWNER: City of Anacortes Phone: 360-299-1948 Address (Street, City, State, Zip): Email Address: dustins@cityofanacortes.org PO Box 547, Anacortes WA 98221 CONTACT I�ERSON: Dustin South Phone: 360-299-1948 Address (Street, City, State, Zip): Email Address: PO Box 547, Anacortes WA 98221 dustins@cityofanacortes.org LENDING AGENCY: N/A Phone: Address (Street, City, State, Zip): Email Address: CONTRACTOR: * TBD - By Sid Phone: Address (Street, City, State, Zip): Email Address Professional License # Exp. Date: *All Contractors &subcontractors must have a valid City of Anacortes business license prior to doing work in the City. Contact the City's Business License #: Exp. Date: Finance Department at (360) 299-1968. PROPOSED WORK: PREFABRICATED restroom unit to be installed on north side of Depot Plaza area. Basement SQ': N/�, 15� Floor SQ': 520 2na Floor SQ': N/A 3`a Floor SQ': N/A 4�' Floor SQ': N/A Garage SQ': Other SQ': Retaining Wall: Yes ❑ No © Fire Sprinkler: Yes ❑ No Occupancy Group(s): Occupant Loads) Type of Construction: Prefabricated concret I declare under penalty of perjury that the information I have provided on this form application is true, correct, and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: Owner ❑ Agent ❑ (specify): Signature: Date: Page 1 of 5 Existing Impervious SQ': IMPERVIOUS 1332 SURFACE AREA* New Impervious SQ': 1332 Total Disturbed Land/Soil SQ': 1332 Total Proposed: Cut: 8 CY Fill: 36 CY New hard surfaces (pervious & impervious) Land converted from native vegetation to lawn or landscaping SQ': 0 Land converted from native Equipment Type: vegetation to pasture SQ': 0 Appliance/Equipment Information (anew and relocated): Total #: Wall Heater: Gas #: Elec #: 1 Other: #: Location(s):Pipe chase 1 Gas Water Heater: #: 1 Location(s): Pipe chase 1 Heat Paillp. Exhaust Fans: Bath #: 2 Laundry #: Kitchen #: Other #: 2 beeation(s). 7 Refrigeration Unit. Elee Other! #. If Fixture Type (new and relocated): TOTAL MECHANICAL OUTLETS: PLUMBING FIXTURES Total # , Fixture Type (new and relocated): Total #: Water Closet (Toilet): 3 Refrigerator water supply (for water/ice dispenser): Kitchen Sink: 1 Pressure Reduction Valve/Pressure Regulator: Utility Sink: 1 Water Service Line: Tub: Water Piping: Hand Sink: 2 Clothes Washer: Shower: Electric Water Heater: Tank -less? Yes ❑ No ❑ * as (tank-1 Page 2 of 5 ss) I PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT COMMERCIAL & MULTI=FAMILY BUILDING PERMIT CHECKLIST Mailing Address: P.O. Box 54 /, Anacortes, WA 98221 Office Location: 904 6" Street, Anacortes WA 98821 Phone: (360) 2934901 PRE -APPLICATION MEETING? ❑ YES � NO IF YES, FILE #: Plans shall be of sufficient clarity to indicate the location, nature, and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: 0 SUBMITTAL REQUIREMENTS:, The number indicates the number of c O copies for submittal (if applicable)., 01 p Commercial & Multi -Family Building Permit Application 1 1 1 1 1 ,>X X Site Plan (Drawn to Scale) 2 2 2 0 2 X Copy of Boundary Survey 2 2 2 0 2 X Building Plans (Drawn to Scale) 2 2 2 2 2 Reduced Site Plan (I I" X 17") 2 2 2 0 2 Reduced Floor Plan (11" X 17") 2 2 2 2 2 X Structural Calculations (if applicable) 2 2 2 2 2 X Energy Code NREC Compliance -including Calculations, 1 1 1 1 1 Lighting, & Commissioning X Stormwater Minimum Requirements 1.9 **Previously submitted 3 3 3 0 0 Landscape Plan 2 2 2 0 0 Parking Plan 2 2 2 0 0 Grading Plan/Cut/Fill 2 2 2 0 0 Critical Areas Report (if applicable) 1 1 1 0 0 Geotechnical Report (if applicable) 1 1 1 0 0 Traffic Impact Analysis (if applicable) 1 1 1 0 1 Plan Review Deposit ✓ ✓ ✓ ✓ ✓ Digital Copy of Plans on Flash/CD (due at permit issuance) ✓ ✓ ✓ ✓ Page 3 of 5 1WL1A 0%1H 1. Handouts and standard details may be found on the City's Planning, Community, & Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, & reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. The drainage analysis /plan & TESC Plan shall comply with the 2012 Department of Ecology's Stormwater Management Manual for Western Washington (as amended in December 2014). 4. Within 180-days of application submittal refunds are allowed up to maximum of 80% of plan review fee so long as no review has been performed by staff (Per IBC 109.6). The applicant must initiate this refund request by submitting a signed letter to the Building Department. Page 4 of 5 Please note, that the subject building permit application will be reviewed by staff for completeness. All of the items above as listed in the "Commercial & Multi -Family Building Permit Checklist" need to be submitted at time of application submittal unless deemed unnecessary by staff. If staff deems the application incomplete, the applicant will be notified by mail and/or email as to what items and/or revisions are still needed. Additionally, if the application is deemed incomplete, the applicant will have 90-days to submit the requested information per AMC 19.20.130(B)(2)(b). If the requested items and/or revisions are not provided by the deadline [90-days], the application may be rejected by staff and returned to the applicant along with any unspent application fees per AMC 19.20.130(C)(3)(b). IS FOR STAFF USE ONLY —COMPLETENESS DETERMINATION. THE t.P:ICATION P ;(CIRCLE If deemed ed incomplete, a is t I e date • it was deemed i I o Iple If If I fd deemed incomplete,,a deemed lled as such at the counter,by lettergor I by letter or emaflilq when Yvas it mailed by USPS or .Ill`V deemed co ICI- e at the counter, when was this cheeldist with items circled (Circle O•) given o the appooicant? 11 deemed co I plet • what is the 90-day deadline for resubmittal of requested items and/or ev isiolis9 If (Please d..IIIed incmill ale e who deemed it .Is sucI 9 include tll'' l' Il in the file detailing additional items or "e' IsIons are still ile`d `d) If such9 the applicationIs deemed tml 1 il't•' what Is the date it was deemed complete & who deemed it as Page 5 of 5 Site Address 607 I� Avg 11 � rig n �„0^ , Project �e5i"a� q Si91 I r� C�/) -- --- � 'J1��rKs � ut�lic i � I I I I — S�.�rrnva?ter I � I I I F ire I I I I Project Enter-neparimen�a{ Plan Q ��� je\N Tracking 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Dec 2019 General Info Project Title: SantiagoS-299 Date 9/11/2020 PROJ-SUM form Project Street Address: RAVE d v,Q� For Building Department Use shall be provided as Project City, County, Zip: ANACORTES, WA 98221 a cover sheet for all compliance form Project Owner or Rep: City of Anacortes submittals. Project Title shall match Jurisdiction: project plans title block. Project Description New Construction and Additions Select all that apply to the scope of project. ❑✓ New Building ® Building Addition FILE Select Addition + Existing Existing Building Retrofit Copy or Alteration + Existing if the existing building will be combined with the addition ❑ Alteration ❑ Change of Occupancy ❑ Change in Space Conditioning or alteration to demonstrate compliance per Section ❑ Historic Building C502.1 or C503.1. Building Elements Scope - Select all that apply ❑ All ❑ Building Envelope Mechanical Systems Q Service Hot Water Systems ❑r Lighting Systems 0 Electrical Systems All Commercial © Group R - R21 R31 & R4 Mixed Use over 3 stories and all R1 Occupancy ��� l9ariC y Type Mixed Use - Building is greater than three stories above grade and it has both Commercial and Group R occupancies. Mixed Occupancy - Building is three stories or less above grade and it has both Commercial and Group R2, R3 or R4 occupancies. Select All Commercial to document compliance for the commercial areas of the building. The residential spaces shall comply with the WSEC Residential Provisions. Select all that apply to the scope of project ❑ Fully Conditioned n Semi-heated2 LJ Refrigerated Spaces (Warehouse and/or Walk-ins) Space Conditioning0 Low Energy Space Category3 Categories Eligible Low Energy Spaces 0 Unconditioned ❑ Low energy heating/cooling capacity ❑ Wireless service ❑ Greenhouse4 ❑ Equipment building equipment shelter Floor Area and Floors Above FloorsBuilding Gross Conditioned Floor Area Project Gross Conditioned Floor Area Stories 1 Q Compliance Method 1 - General C Compliance Method 2 - Total Building Compliance Method t - Projects shall demonstrate compliance with all applicable mandatory and General Compliance prescriptive requirements of this code. Refer to C401.2, Item 1 for more information. Compliance forms to include with a Prescriptive submittal: All applicable ENV, LTG, and MECH. Path Compliance Method 2 - Projects complying via total building performance (TBP) shall include a summary of results from a whole building energy model per Section C407 and shall demonstr liance with all applicable mandatory provisions in this Code. Refer to Section C401.2, Item 2 frRown, Compliance forms to include with a TBP submittal: PROJ-SUM, ENV-CHK, ! all MECH forms except MECH-ECONO and MECH-VENT (pending). C Note 1 -Refrigerated Spaces -They shall comply with the envelope and refrigeration equipment requ coolers and freezers shall also comply with the envelope requirements in C402. C410 takes Note 2 - Semi -heated Spaces - If heated with equipment other than electric resistance may take an e) envelope assemblies shall comply with the thermal envelope provisions. r"�% Note 3 -Exemptions For Low Energy Spaces -Low Energy spaces are exempt from all provisi ns in I however all other applicable provisions in the Cc o pl c ec cal, Note 4 -Eligible Space Conditioning For Low Energy� c sA fi as environment that is used exclusively for cull i Jr I n o la Cc cooling, and any form of heating equipment, al owed under the Low Ene rgreenhouse equipment that requires a condensing unit are NOT eligible. 1 Iuv_r c 2 2M ( EJct�IREs April 23, 2Q21 September 16, 2020 'PT1( OF ANACORTE 2015 WSEC Compliance Forms for Commercial Buildings including R2, R31 & R4 over 3 stories and all R9 Revised Dec 2019 General Info I Project Title: SantiagoS-299 Date 9/11/2020 C406 Additional Building level efficiency options: Current Scope Previous Projects C406.8 Enhanced envelope performance ❑ ❑ Efficiency Package Options Summary C406.9 Reduced air infiltration ❑ ❑ A minimum of two Options are required for new construction, C406.5 On -site renewable energy ❑ ❑ and change in space conditioning or occupancy Building area level efficiency options projects. C406.2 More efficient HVAC equipment ❑ ❑ Select all Options included in the current project scope. Also select Options complied C406.6 Dedicated outside air systems (DOAS) ❑ ❑ with under previous projects (shell and core, other tenant spaces in building, etc) Buildings with multiple tenant C406.7 Reduced energy use in service water heating ❑ ❑ C406.3 Reduced lighting power 1❑ ❑ spaces may comply with C406.4 Enhanced digital lighting controls ❑ ❑ different options (mix & match). C406 Comments: Options are required for all All options but C406.3 are not applicable for this project. space conditioning categories. Include discipline specific information for C406 options in ENV -SUM, LTG -SUM and Refer to SBCC website for official interpretations regarding C406 provisions. EXPIRES Apr 123, 24�1.. September 16, 20?0 2015 Washington State Enerav Code Compliance Forms for Commercial Buildinas including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Project Title: SantiagoS-299 Date 9/11/2020 Compliance forms do not Applicantlnformation. Provide contact information for individual Mo can respond to inquiries about compliance form information provided. For Building Department Use require a password to Company Name: CXT Precast Products, Inc. use. Instructional and Company Address: 6707 E. Flamingo Ave Bldg 300, Nampa, ID 83687 calculating cells Applicant Name: All Cairns are wite- protected. Applicant Phone: 509-892-3238 Applicant Email: Acairns@lbfoster.com Project Description 0 New Building QAddition QAlteration Q No Lighting Scope Include PROJ-SUM form (included in envelope forms wrkbook) Kith lighting compliance forms. Interior Lighting System Two (2) lights servicing each men and women bathroom Description One (1) light servicing the utility room Two (2) lights servicing the chase ® Interior Lighting Plans Included Interior Lighting Power 0 Building Area Method Space -by -space Method Allowance Method Select method used in project. Interior Lighting Controls 61 All C405.2.1- C405.2.8 Lighting Controls OC405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) o Additional Efficiency Package Option C406.4 Enhanced Digital Lighting To comply faith C406.4, no less than 90% of the total installed interior lighting poster shall comply with required controls per C406.4. Dwelling Unit Interior Lighting Permanentlyinstalled interior lighting fixtures in duelling units comply with: 40 No Dwelling OC405.2 thru C405.5 Commercial Lighting Controls and LPA Units OC406.3 High Efficacy Lighting OR404.1 Residential High Efficacy Lighting. Duelling unit lightingcomplies faith WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Description ® Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting . .....................................__....._.....................................................- ......_._.. .... _..................._._...._............. _. _._.._._._....._..... Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Refer to Section C502.2.6 for addition I requirements. _........_ .................. .................................. ...................... ....... ... .__.__._____.___.___ systems in addition are combined with existing 0 0 iAm ing systems to demonstrate compliance p4 C? �t C 3 '►T °r s Z -------------- -- .._.... _..------------- ------ --- ---- mbined with existing: r ting projects, include new + existing -to -remain interior lighting fixture Kettage in os gWattage table in LTG-INT-BLD orLTG-INT-SPACE form. xten r ing projects, include new + existing -to -remain exterior lighting fixture "ettage in se d le and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. 9 FCjS,�gQ �w �sS/nNAL ��G� EXPIRES April 23, 2021 wr�r�r September 16, 2020 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R31 R4 over 3 stories and all R1 Revised Nov 2017 IProjectTitle: SantiagoS-299 (Date 9/11/2020 Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced 0 0 0 Select all Lighting Power and Lighting Control elements that apply to the scope Less than 50% of existing are replaced 0 0 of the retrofit project. If project includes a combination of spaces inhere less than Lamp and/or ballast replacement only 50% of the existing fixtures are replaced —existing total wattage not increased 0 F7 in some spaces, and not others, the of the 50% or more replaced - Total li htin over of new+ existin to -remain fixtures shall coin I with fixtures are replaced in others, then total LPA per Sections C405.4.2 and C405.5.2. Include new +gexisting-to-remain fixtures in y provide separate lighting poorer compliance forms for the two retrofit Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. conditions. Spaces undergoing the same Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed type of retrofit may be combined into one the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed lighting power compliance form. Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to numberof luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wettage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All ......... _._.__......... alteration lightingconshall a New wiring installed to serve added commissioned perC408,3, .3. fixtures and/or fixtures relocated to 0 0 0 new circuit(s) New or moved lighting panel 0 0 0 Interior space is reconfigured - luminaires unchanged or relocated 13 New wiring or circuit - Forinteriorlighting, provide required manual controls perC405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application ® No changes are being made to specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7, the interior or exterior lighting New or moved panel - Provide all applicable lighting controls as noted for New Wiringand automatic systems and existing space time switch controls per C405.2.2, uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed, space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured EXPIRES April 23, 2t121 September 16, 2020 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R9 Revised Nov 2011 Project Title: Santiago S-299 Date 9/11/2020 Calculation Area NOTE 9 ®New Construction Q Addition - Q Spaces where < 50% of O Spaces where >_ 50% of Q Addition O Spaces where the Use For Building Department Use LPA Calculation Type Q Standard Additional Efficiency Package Option C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting Wattage"' Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in f12 Allowed Watts per ftz Watts Allowed (watts/ftz x area) Bathrooms Restroom: all other 387 0.780 302 Chase Workshop 72 1.270 91 utility Workshop 61 1.270 77 Lobby Art/Exhibit Display Allowancefrom LTG-INT-DISPLAYNOTEs� Total Area 520 Retail Display Allowance from LTG-INT-DISPLAY Allowed Watts 471 Proposed Lighting Wattage "°TE' Location (plan #, room #) Fixture Description NOTea, s, s Number of Fixtures Watts/ Fixture NOTES Watts Proposed Bathrooms Surface Mounted Wrap -around (1) 28W LED 4 28 112 Chase Surface Nbunted Wrap -around (1) 28W LED 2 28 56 utility Surface Nbunted Wrap -around (1) 28W LED 1 28 28 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 196 Interior Lighting Power Allowance COMPLIES WITH C446.3 Note 1 -List all unique space types per Table C405.4.2(2) that occurin the project scope. Select space type category from drop down menu. Note 2 -Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 -List all proposed lighting fixtures including exempt lighting equipment and existing -to remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (a.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1. note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 -For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or I luminaires with screvuin lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the voltage lighting, enter the wattage of the transformer. For line voltage track/buswey systems, enter the larger of thei wettsAineal foot, or enter the wattage limit of permanent current limiting device. Note 8 -Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. nt"l p fixtures in LTG-INT-DISPLAY form only. Note 9 -Calculation Area Details: ,r a. Lighting fixtures in a building addition may comply as a stand alone project, or they may 4414Wblinedi lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum a building addition will comply as combined with the overall existing building lighting systems, include all and cross interior areas. Septetnl�er 16, 2020 zu i a vvasnm ton [ace cner co°e com nance rorms ror �ommerciai esuuam s inciuQin KZ K pill K4 Over 3 Si0ne5 anQ all K K@NSBQ NOV ZU I / Project Project Title: SantiagoS-299 Date 9/11/2020 Exterior Lighting Zone * Zone 1 4 Zone 2 0 Zone 3 0 Zone 4 Exterior Lighting Zone selection required to enable LTG-EXT form. Zones are defined in Table C405.5.2(1) and specified by the For Building Department Use Calculation Area New construction 0 Addition- stand alone 0 Addition + existing o Alteration with < 50% 0 Alteration with >_ 50% ext. ext. wattage replaced wattage replaced User Note Building Grounds Applies to individual luminaires > 100 Watts 0 Efficacy > 80 lumens/watt 0 Exemption 0 Controlled by motion sensor Tradable Maximum Allowed Lighting Wattage NOTE? Base Site Allowance: 500 Tradable Surfaces Surface Description Area (ft), perimeter (If) or # of items Allowed Watts per e or per If Allowed Wafts x ft2 (or x If) NOTE 2 Main Entry Door 12 20W/LF door 240 Total Allowed Tradable + Site Allowance Watts: 740 Tradable Proposed LiLyhtinL WattaLye NOTE Tradable Surtace Fixture Description NOTE a, e Number of Fixtures Wafts per Fixture NorE s Watts Proposed Main Entry Door 14W LED 3 14 42 Total proposed tradable watts may not exceed the sum of total a/lowed tradable Total Proposed Tradable Watts: mmtts nlus the hasp site allnmenre Anv haze site allnVwnre not neerierl to 42 make tradable watts comply can be applied to individual non -tradable Non=lradable Maximum Allowed Lighting Watta ge'"""' Site Allowance Remaining: All per ft2, If or item Non -Tradable Proposed Lighting Wattage NOTES,' 500 owed Watts X ft2 (or X If) NOTE 2 Number of atts per Non -Tradable Surface Fixture Description NOTE 415 Fixtures Fixture NOTE s Proposed Watts Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Exterior Lighting Note 1 -List all exterior surfaces per Table C405. o Note 2 - Unlit Message - Enter lighting fixture in for 1 Note 3 - List all proposed lighting fixtures includi tom Note 4 - For proposed Fixture Description,pindic Ir type, Note 5 - Existing -to -remain fixtures still be Acl { as new fixtures. Identify as tin g n d do . Note 6 -For proposed Watts/Fixtu e he lum luminaires with screwin lamps, enter the voltage Aghtinq, enter the wattage of the trans ]VAL Non -Tradable Watts Exceeding LPA: 0 Remaining Site Allowance: 500 Select exterior surface categories from drop down menu Lighting Wattage table to generate Lighting Power Allows lamps in the fixture, and ballast type (if applicable). le Proposed Lighting Wattage tables in the same manner and ballast using manufacturer or other approved source. For input wattage of the fixture (not the lamp wattage). For low EXPIRES April 23, 2t}2i September 1C, 2020 Number of atts per Non -Tradable Surface Fixture Description NOTE 415 Fixtures Fixture NOTE s Proposed Watts Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Exterior Lighting Note 1 -List all exterior surfaces per Table C405. o Note 2 - Unlit Message - Enter lighting fixture in for 1 Note 3 - List all proposed lighting fixtures includi tom Note 4 - For proposed Fixture Description,pindic Ir type, Note 5 - Existing -to -remain fixtures still be Acl { as new fixtures. Identify as tin g n d do . Note 6 -For proposed Watts/Fixtu e he lum luminaires with screwin lamps, enter the voltage Aghtinq, enter the wattage of the trans ]VAL Non -Tradable Watts Exceeding LPA: 0 Remaining Site Allowance: 500 Select exterior surface categories from drop down menu Lighting Wattage table to generate Lighting Power Allows lamps in the fixture, and ballast type (if applicable). le Proposed Lighting Wattage tables in the same manner and ballast using manufacturer or other approved source. For input wattage of the fixture (not the lamp wattage). For low EXPIRES April 23, 2t}2i September 1C, 2020 Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Exterior Lighting Note 1 -List all exterior surfaces per Table C405. o Note 2 - Unlit Message - Enter lighting fixture in for 1 Note 3 - List all proposed lighting fixtures includi tom Note 4 - For proposed Fixture Description,pindic Ir type, Note 5 - Existing -to -remain fixtures still be Acl { as new fixtures. Identify as tin g n d do . Note 6 -For proposed Watts/Fixtu e he lum luminaires with screwin lamps, enter the voltage Aghtinq, enter the wattage of the trans ]VAL Non -Tradable Watts Exceeding LPA: 0 Remaining Site Allowance: 500 Select exterior surface categories from drop down menu Lighting Wattage table to generate Lighting Power Allows lamps in the fixture, and ballast type (if applicable). le Proposed Lighting Wattage tables in the same manner and ballast using manufacturer or other approved source. For input wattage of the fixture (not the lamp wattage). For low EXPIRES April 23, 2t}2i September 1C, 2020 and ballast using manufacturer or other approved source. For input wattage of the fixture (not the lamp wattage). For low EXPIRES April 23, 2t}2i September 1C, 2020 Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG=CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Santiago S-299 Date 9/11/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability Location in Building Department (yes,no,na) Code Section Component I Compliance information required in permit documents Documents Notes LIGHTING CONTROLS Lighting controls, For all lighting fixtures, indicate lighting control method on plans Yes C405.2 general for spaces and lighting zone(s) served, or exception taken S-321 S-33 Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of NA C405.2 lighting controls C405.2 lighting controls; provide description of control (LLLC) capabilities and performance parameters For permanently installed lighting fixtures in dwelling units, NA C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and units lighting zone(s) served, or demonstrate compliance with high efficacy exception C405.2.3 Indicate on plans the method of manual lighting control (whethe Yes C405.2.1.1 C405.2.2.2 Manual controls combined with occupancy sensor, automatic light reduction, S-32, S-33 daylight responsive or specific application controls), location of C405.2.4 manual control device and area or specific application it serves C405.2.5 C405.2.2.1 Indicate on plans which method of manual 50% lighting load Yes C405.2.2.2 Manual interior light reduction is provided, or whether lighting load is reduced via S-321 S-33 reduction controls C405.2.3 occupancy sensors or daylight responsive controls Indicate on plans the method of automatic shut-off control durin unoccupied periods (occupancy sensor, time switch or digital S-32, S-33 Method of automatic timer switch) for all lighting zones; Yes C405.2.2 shut-off control __ _ Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies Indicate on plans the spaces served by occupancy sensors; S-323 S-33 Indicate whether occupancy sensor controls are configured to Yes C405.2.1 Occupancy sensor C405.2.1 A controls be manual -on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception Occupancy sensor Indicate aisleways and open areas in warehouse spaces NA C405.2.1.2 controls - provided with occupancy sensor controls that reduce lighting warehouses power by 50% Automatic time Indicate locations of override switches on plans and the lighting Yes C405.2.2.1 switch controls zone(s) served, include area sq. ft. S-32, S-33 Indicate digital timer switch control includes: manual on/off, time NA C405.2.6 Digital timer switch delay, audible and visual indication of impending time-out Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq, ft_; NA C405.2.4.2 Daylight zones - For small vertical fenestration assemblies (rough opening less C405.2.4.3 Sidelight and toplight than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) tha NA C405.2.4 Daylight responsive apply; controls Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone Additional controls Identify spaces and lighting fixtures on plans that require NA C405.2.5 Specific application specific application lighting controls per this section lighting controls Indicate on plans that display and accent lighting, and display C405.2.5 - Display and accent case lighting are controlled independently from both general NA Items 1 &2 lighting area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting, Motor,and Electrical Permit Checklist, Pg. 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Santiago S-299 I Date 9/11/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes C405.2.5 - Hotel/motel guest Indicate method of automatic control - vacancy or captive key NA Item 3 control of all installed luminaires and switched receptacles in rooms guest room Indicate method and location of automatic shut-off vacancy NA C405.2.5 - Supplemental task control for supplemental task lighting, including under -shelf or Item 4 lighting under -cabinet lighting Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled C405.2.5 - Lighting for non- NA independently from both general area lighting and other lighting Item 5 visual applications applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general C405.2.5 - Lighting equipment area lighting and other lighting applications within the same NA Item 6 for sale or space; demonstration Indicate method of manual lighting control and applicable automatic lighting control Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress _ NA C405.2.5 - Means of egress lighting; Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq, ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; _ Indicate method of automatic shut-off control Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and S-32, S-33 locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed Yes C405.2.7 Exterior lighting opening/closing time; controls For all other exterior lighting, indicate automatic controls shut ofl lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor For building grounds fixtures greater than 100 wafts, indicate on Exterior building plans whether fixtures have efficacy greater than 80 lumens or; NA C405.5A grounds lighting are controlled by motion sensor, or are exempt lighting per controls C405.5.2 Area controls - Indicate location(s) of master control switch(es) intended to C405.2.5 Master control control multiple independent switches; circuit breaker may not NA (listed after switches and circuit be used as a master control switch; C405.2.7) limit Verify that no 20 amp circuit controlled by a single switch or power automatic control is loaded beyond 80°/u ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Enhanced digital NA C406.4 lighting controls 9 9 Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG=CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R31 R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Santiago S-299 I Date 9/11/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability Location in Building Department (yes,no,na) Code Section Component I Compliance information required in permit documents Documents Notes INTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per S-32, S-33 fixture; Identify spaces eligible for lighting power exemption onplans C405AA Total connected and in compliance forms; indicate the exception applied; Yes C405.4.2 interior lighting power Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently Indicate location of exit signs on plans and rated watts per NA C405.3 Exit signs fixture in lighting fixture schedule (maximum 5 watts per side) If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture NA C405.1 Lighting in dwelling schedule if lamps in fixtures are high efficacy per R404.1. units -lamp efficacy Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Interior Lighting Power Calculation - Indicate compliance path taken Complete required compliance forms — proposed wattage per Yes C405.4.2.1 Building Area building area does not exceed maximum allowed wattage per S-323 S-33 Method building area; identify locations of building areas on plans Complete required compliance forms — total proposed wattage Space -By -Space does not exceed maximum allowed wattage; identify locations o NA C405.4.2.2 Method space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior Yes C406.3 Reduced lighting lighting wattage is 25 /o less than the total maximum allowed power density lighting wattage via Building Area Method or Space -By -Space Method For project with dwelling units, to comply with additional Reduced lighting efficiency package option indicate in lighting fixture schedule if NA C406.3 power density - lamps in interior fixtures have efficacy rating of 60 lumens per dwelling unit lamp watt or more. Calculate percentage of fixtures with lamps that efficacy have this efficacy rating (min 95 /o to comply with option) EXTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; _ Identify exterior applications eligible for lighting power Total connected exemption on plans and in compliance forms; indicate exception Yes C405.5.2 exterior lighting applied; power Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.5.2(1) For building grounds fixtures rated at greater than 100 watts tha NA C405.5.1 Exterior building are complying based on efficacy, indicate rated lamp efficacy (i grounds lighting lumens per watt) in fixture schedule Complete required compliance form — proposed wattage for Yes C405.5.2 Exterior lighting exterior lighting plus base site allowed does not exceed power calculations maximum allowed Lighting, Motor, and Electrical P ermit Checklist, • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R31 R4 over 3 stories and all R1 Revised Nov 2017 Santiago S-299 Date 9/11/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING ALTERATIONS Where z 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate compliance path (building area or space -by -space method); include all new and existing4 remain luminaires in compliance form (LTG-INT-BLD or LTG- INT-SPACE); indicate proposed lighting wattage does not Interior and parking exceed maximum allowed per compliance path NA C503.6 garage lighting fixture alterations Where < 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in LTG-INT-SPACE form; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration Where >_ 50% of existing exterior lighting wattage is replaced; include all new and existing4o-remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed maximum allowed Exterior lighting NA C503.6 Where < 50% of existing exterior lighting wattage is replaced; fixture alterations indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not excee total existing wattage prior to alteration Where new wiring is installed to serve new interior luminaires Interior lighting wiring and /or luminaires are relocated to a new circuit; indicate lightin NA C503.6 alterations controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); daylight responsive (C405.2.4); specific application (C405.2.5); exit signs (C405.3) Exterior lighting Where new wiring is installed to serve new exterior luminaires Exte NA C503.6 Exteri alterations and /or luminaires are relocated to new circuit; indicate exterior wirinlighting controls are provided (C405.2.7) Where a new lighting panel is installed or an existing panel is Lighting panel moved (all new raceway and conductor wiring); indicate lighting NA C503.6 alterations controls are provided (as applicable) - same provisions as wiring alterations; time switch controls and manual light reduction controls (C405.2.2) Where interior space(s) is reconfigured (permanently installed NA C503.6 Interior space walls or ceiling -height partitions); indicate lighting controls are reconfiguration provided (as applicable) - same provisions as lighting panel alterations Identify existing luminaires being upgraded with bulb and / or NA C504.2 Lighting repairs ballast replacement; indicate fixture alteration does not increase existing fixture wattage Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables C405.4.2(1) or (2) NA C505.1 Change of space use Indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in compliance form (LTG-INT-BLD or LTG-INT-SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Identify all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include Controlled receptacle configuration such as spacing between controlled NA C405.10 receptacles and uncontrolled, duplex devices, etc; --- --— — --- — --- Indicate on plans whether the method of automatic control for each controlled receptacle zone is by occupant sensor or programmable time -of -day control Lighting, Motor, and Electrical Permit Checklist, • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R31 R4 over 3 stories and all R1 Revised Nov 2017 Santiago S-299 Date 9/11/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability Location in Building Department (yes,no,na) Code Section Component I Compliance information required in permit documents Documents Notes MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C405.6 Electrical Include electrical transformer schedule on electrical plans; transformers indicate transformer size, efficiency, or exception taken Dwelling unit Indicate on electrical plans that each dwelling unit in Group R-2 NA C405.7 electrical energy has a separate electrical energy meter consumption Electric motor Include all motors, including fractional hp motors, in electric NA C405.8 efficiency motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; NA C405.9.1 Elevator cabs Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more Escalators and Indicate escalators comply with ASME A17.1/CSA B44; NA C405.9.2 moving walks automatic controls are configured to reduce operational speed t the minimum permitted when not in use NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) Indicate that all electrical systems (receptacles, transformers, motors, vertical and horizontal transportation) for which the WSEC requires control functions and / or configuration to Scope of electrical perform specific functions are required to be commissioned; NA C408.3 power and lighting Where total building lighting load is > 20 kW, or where total systems commissioning lighting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception; Indicate Cx requirements in plans and specifications for all applicable electrical and lighting control systems per C408; Include general summary with at minimum Items 1 thru 4 of the C405.13 Cx plan per C408.1.2 including: narrative description of Commissioning C408.1.1 requirements in activities, responsibilities of the Cx team, schedule of activities NA C408.1.2 including verification of project close out documentation per C408.1.4.2 construction C103.6, and conflict of interest plan (if required); C103.6 documents Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final electrical inspection Functional Identify in plans and specifications the intended operation of all NA C408.3.1 performance testing equipment and controls during all modes of operation, including criteria interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION Indicate in plans that project close out documentation is Project close out required including WSEC lighting compliance forms and NA C103.6.3 documentation calculations that document all interior and exterior lighting area requirements and / or surface types, lighting power allowances and installed densities If 11no" is selected for any question, provide explanation: 2015 WaSllington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH=SU Mff 2015 Washington State Energy Code Com fiance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Janua 2017 Project Information Project Title: SantiagoS-299 Date 1/1/2015 Applicant Information. Provide contact information for individual who can respond to For Building Dept. Use inquiries about compliance form information provided. Company Name: CXT Precast Products, Inc. Company Address: 6707 E. Flamingo Ave Bldg 300, Nampa, ID 83687 Applicant Name: All Cairns Applicant Phone: 509-892-3238 Project Description ❑J New Building ❑ Building Addition ❑ Tenant Improvement ❑ System Retrofit ❑ No System Changes Briefly describe mechanical systems in Natural Gas Water Heater is being utilized on this project. the text box provided ❑ Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. ❑ Load calculation summary ❑ MECH-LOAD-CALC Form Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. ❑r Mechanical Plans ❑ MECH-EQ Forms (TBD) Mechanical Schedules Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. ❑ DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupancies) All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does not require space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling is required. Dedicated Outdoor Air ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1) System Requirements and ❑ ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception High Efficiency VAV ❑ DOAS included in project, although not required (occupancy not office, retail, education, library or fire station) Alternate ❑ DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per C402.4.1.4 with 100% of conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. ❑ Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. Fan Power ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a separate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Water -loop heat pump ❑ No hydronic systems ❑ Hydronic heating water ❑ Geothermal ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) ° ore efficient than C406 Additional minimum requirements. All stand alone supply, return, and exhaust fans ov ru# > 71 and must be selected within 10% of maximum total or static pressure. Efficiency Options - ❑ C406.6 Dedicated outdoor air system (DOHS) . p WAr C Mechanical Requires 90% of conditioned floor area to be served by a DOAS per d er: qJ tion air in a manner that does not require space conditioning fan operation. �t' ❑ C406.7 Reduced energy in service water heating w.� Requires 90% of floor area be in occupancy types listed In C41.7 . ar e' t 6 hot w too rgy use be provided by heat pump, waste heat recovery or solar w hn s EXPIRES Aprril 23, 2021 7 September 16, 2020 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical SuWgmary, • • A 0 1 k kI 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Equipment Type (s) 0 Hot water heating tank(s) ❑ Instantaneous ❑ No service water systems Service Water Heating Systems ❑ Dedicated boiler ❑ Heat exchange from space heat boiler or Distribution Type (s) central hot water/steam ❑ Circulation System 0 On -demand commissioning Commissioning is required for: ❑ Mechanical systems per C408.2 ❑ Service water heating systems per C408.4 If required, commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: ❑ Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating. Mechanical systems commissioning not required. Capacity of largest service water heating system in building does not exceed 200,000 Btu/h. Service water heating systems commissioning not required. Low Energy and Semi -Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Type Location in Plan(s) Space(s) Served Area Served, square feet Capacity, Btu/h (Note 4) Capacity, Btu/h (Note 5) Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C402.1.1 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h sf. Note 7 - Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. EXPIRES April 23, 2Q21 September 16, 2020 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 20 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R9 Revised January 2017 Project Title: SantiagoS-299 I Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes Equipment - Sizing, Performance and Type Identify equipment to be used in manufacturing, industrial or commercial processes that do not NA Exempt process equipment provide space conditioning; identify provisions applicable to this equipment per C403.1 exception EC403,2.1 Provide load calculations performed per ASHRAE Std 183 or equivalent, using design NA Load calculations parameters per C302 and Appendix C; include load adjustments to account for energy recovery Indicate that output capacities of heating and cooling equipment and systems are no greater NA C403.2.2 Equipment and system than the smallest available equipment size that exceeds the calculated loads; note exceptions sizing taken Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, C403.2.3 HVAC equipment rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply NA C403.2.3.2 performance requirements and OSA cfms and operating hours for all air systems; identify heating and cooling equipment C403.2.13.1 (efficiency) that does not have a corresponding WSEC minimum efficiency (manufacturer rated) List all motors? 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated NA C405.8 Electric motor efficiency efficiency, or exception applied C403.2.14 For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or NA C403.2.11 A Fan power limitation bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified NA C403.2.11.2 Motor nameplate hp are the smallest available motor hp size greater than fan bhp, note exceptions taken For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is >_ 67, or NA C403.2.11.3 Fan efficiency exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency Group R occupancy exhaust For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the NA C403.2.11.4 fan efficacy fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE-57) For fan motors t 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in NA C403.2.13 Variable flow capacity - equipment schedule, or exception taken; for equivalent method for an HVAC system refer to fans HVAC System Controls for additional requirements Maximum air cooled chiller For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled NA C403.2.3 capacity chiller capacity is!- 100 tons, or exception taken For buildings with >_ 300 tons of cooling capacity, indicate method of multi -stage or variable NA C403.4 Large capacity cooling o capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66 Jo systems of the total) For water-cooled centrifugal chillers not designed for operation at standard conditions, provide NA C403.2.3.1 Non-standard water-cooled calculations documenting maximum full load and part load rated equipment performance centrifugal chillers requirements C403.2.13.1 Centrifugal fan open -circuit For open -circuit centrifugal fan cooling towers with t 1te,100 gpm capacity, indicacooling NA C403.4.3.2 cooling towers towers comply with efficiency requirements for axial fan open circuit cooling towers For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating bumer NA C403.4.2 Large capacity boiler For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate turndown ratio C403.4.2.5 systems per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) For pump motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent NA C403.2.13 Variable flow capacity - method) in equipment schedule, or exception taken; for equivalent method for a hydronic pumps system refer to Hydronic System Controls for additional requirements Gas and oil -fired forced air For forced air furnaces with capacity >_ 225,000 Bluth and all unit heaters, indicate in NA C403.2.3 furnace and unit heaters equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss Combustion heating For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating NA C403.2.4.8 equipment or staged combustion control Packaged electric heating / Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of NA C403.2.3.3 cooling equipment heating is a heat pump; include in equipment schedules Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant NA C403.2.12 Heating outside a building systems; refer to HVAC System Controls for additional requirements Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC NA C403.23A Kitchen exhaust hoods System Controls for additional requirements Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate NA C403.2.4.3 Outdoor supply air, exhaust whether dampers are Class 1 motorized, or gravity and exception taken (include leakage and relief dampers rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers Indicate locations of return air dampers that are integral to economizer operation; verify NA C403.2.4.3 Return air dampers dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 20 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: SantiagoS-299 Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Location in Building Department Code Section Code Provision Information Required - Must be in permit documents Documents Notes (yes,no,na) Stairway and shaft vent Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 NA C403.2.4.3 dampers motorized; refer to HVAC System Controls for additional requirements For systems serving areas > 25,000 sf or spanning more than one Floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and NA C403.2AA Zone isolation dampers locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements For cooling systems with humidification equipment that are also required to have air NA C403.2.3.4 Humidification economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible To comply with additional efficiency package option, calculate the percentage of heating and NA C406.2.1 HVAC system selection cooling equipment in the project (based on output capacity) that do not have a corresponding C403.2.3 WSEC listed efficiency; shall be less than 10% to comply C406.2.2 Minimum equipment To comply with additional efficiency package option, indicate that all listed heating and cooling NA C403.2.3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% To comply with additional efficiency package option, indicate rated FEG of stand alone fans is NA C406.2.3 Minimum fan efficiency i 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of C403.2.11.3 the maximum total or static efficiency HVAC System Controls Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent Thermostatic controls openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones NA C403.2AA (thermostats and from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter humidistats) zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 50F higher than the adjacent perimeter zone temperature in heating Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and NA C403.2.4.1.1 heat supplemental heating controlled with outdoor lock -out temperature set to 40OF or less Indicate zone thermostatic controls configured with 50F minimum deadband for systems that NA C403.2.4.1.2 Deadband control both heating and cooling If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve NA C403.2.4.1.3 Setpoint overlap restriction on plans (thermostats) Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling C403.2.4.2 Indicate zone thermostatic controls configured with required automatic setback and manual NA C403.2.4.2.1 Automatic setback and override functions, setback temperatures, and control method (automatic time clock or C403.2.4.2.2 shutdown programmable controls); note exceptions taken Indicate system controls that adjust equipment start time required to bring each area served NA C403.2.4.2.3 Automatic (optimum) start up to design temperature just prior to scheduled occupancy Indicate automatic controls configured to close OSA damper during unoccupied equipment NA C403.2.4.3 Outdoor supply air dampers operation; not including economizer cooling, night flush or IMC required OSA / exhaust Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of NA C403.2.4.3 dampers power) For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that NA C4032.4.4 Zone isolation controls are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken Indicate occupancy sensing or timer switch controls configured to automatically shut off NA C403.2.12 Heating outside a building heating system when area served is unoccupied Indicate automatic controls configured to shut off system when pavement temperature NA C403.2.4.5 Snow melt systems exceeds 50OF and no precipitation is falling, and when outdoor air temperature exceeds 40OF Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or NA C403.2.4.6 controls conditions protect fluid from freezing For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest NA C403.2.4.9 Group R1 hotel / motel rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at guest rooms least 50F; indicate control method - activated by room entry or occupancy sensor 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 20 �M A AAInQhinntnn Rtatp Fnprnv Cndp Cmmnliancp Fnrms fnr Commercial Buildinas includina R2 & R3 over 3 stories and all R9 Revised January 2017 Project Title: SantiagoS-299 jDate 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes (yes,no,na) Group R2 / R3 dwelling For primary space conditioning system, indicate 5-2 programmable thermostats capable of two NA C403.2.4.10 units, Group R2 sleeping setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or C403.2.4.11 units both), required temperature range and at minimum a 10°F deadband; or exception taken Indicate method of ventilation air delivery (natural or mechanical) for each zone If mechanically delivered, indicate that systems are configured to provide not more than 150 % S-32 Yes C403.2.6 Ventilation of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE C403.2.11.4 62A or other applicable code (WAG, OSHA, etc); or exception taken If delivered via natural ventilation, identify required elements per IMC including minimum operable area to the outdoors or qualifying adjoining spaces Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or NA C403.2.6.2 Demand controlled the system has airside economizer or automatic modulating OSA damper; indicate OSA ventilation controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based S-32 OSA control when space is unoccupied and method (closes OSA damper or shuts -off Yes C403.2.6.3 Occupancy sensors equipment); or alternate means provided to automatically reduce OSA when space is partially occupied For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas NA C403.2.6.4 Enclosed loading dock detection system for CO and NO2, or occupancy sensors), and control method (staged or C403.2.6.4.1 ventilation modulating) C403.2.6.4 Enclosed parking garage For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection NA C403.2.6.4.2 ventilation system for CO and NO2, and control method (staged or modulating); or exception taken Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10 % of hood exhaust NA C403.2.7.1 Kitchen exhaust hoods For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements For HVAC fan motors z 7.5 hp, indicate method of variable flow control (VSD, or equivalent NA C403.2.13 Variable flow capacity - control method that reduces design air volume by 50% at 1/3 static design pressure); note HVAC system fans exception taken For DX air handlers with economizer and cooling capacity> 65,000 Btu/h, indicate number of DX air handler variable cooling stages provided and method (multiple compressors and / or variable speed NA C403.3.1 cooling control compressors); indicate minimum displacement (capacity reduction) as % of full load (Under Integrated Economizer) Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) For DX air handling units with cooling capacity- 65,000 Btu/h and evaporative and chilled water air handling units with fan >- 0,25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; NA C403.2.11.5 Fan airflow control indicate minimum fan speed is <- 66%of full speed drawing <- 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is <- 50% of full speed drawing 5 30 % of full speed fan power during periods of low cooling or ventilation only; or exception taken Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table C403.2.4.12.1 NA C403.2.4.12 DDC system capabilities Identify all DDC system input / output control points; indicate capability for trending and graphical display Ducting Systems Indicate on plans that all ductwork is constructed and sealed per IMC NA C403.2.8.7 C403.2.8.3 Duct construction For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC NA C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide test results to NA C403.2.8.3.3 Vest jurisdiction when completed 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 8 of 20 �ni s Wachinntnn State Fnernv Code Comnliance Forms for Commercial Buildinas including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: SantiagoS-299 I Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable Location in Building Department Code Section Code Provision Information Required - Mustbe in permit documents Documents Notes (yes,no,na) For supply and return ductwork located in unconditioned space or outdoors, indicate R-value of insulation on ductwork on plans; identify climate zone; note exceptions taken For supply ductwork located in conditioned space, identify if design supply temperature is < NA C403.2.8.1 Duct insulation 55OF or> 105OF and indicate R-value of insulation on this ductwork on plans; note exception C403.2.8.2 taken For OSA ductwork, shafts and plenums, indicate R-value of insulation on these elements on tans per Table C402.1.3 for steel -framed walls; note exception taken Piping Systems Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in NA C403.2.9 Piping insulation inches) on hydronic piping plans; or exception taken Piping insulation exposed to Indicate method of protection of pipe insulation from damage / degradation on hydronic piping NA C403.2.9.1 weather 1plans Economizers Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including NA C403.3 Air economizer required those with water -side economizer in lieu of air economizer; indicate on plans eligible exception(s) taken and measures to comply with exception(s) Integrated economizer Indicate air and water -side economizers are configured for partial cooling operation even NA C403.3.1 operation - air and water where additional mechanical cooling is required to meet the load Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating NA C403.3.2 impact - air and water energy usage during normal operation Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA NA C403.3.3.1 Air economizer capacity for cooling Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet NA C403.3.1 Integrated air economizer the cooling load, until the leaving air temperature is < 450F C403.3.3.2 For systems with cooling capacity >_ 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NA C403.3.3.3 Air economizer high limit Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 controls For eligible systems where water -side economizer may be provided in lieu of air economizer, NA C403.3AA Water economizer capacity indicate system is capable of 100% design cooling capacity at 50OF db / 450F wb OSA temperatures Water economizer Indicate pressure drop across precooling coils and heat exchangers in water economizer NA C403.3.4.2 maximum pressure drop system do not exceed pressure drop limit DX air handling equipment For DX air handlers with economizer and cooling capacity 2: 65,000 Btu/h, refer to HVAC NA C403.3.1 control System Controls for requirements DX equipment economizer For DX air handlers with economizer and cooling capacity z 54,000 Btu/h, provide a fault NA C403.2.4.7 fault detection and detection and diagnostics (FDD) system to monitor economizer system operation and report diagnostics faults Systems Requiring Energy Recovery For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Energy recovery (ER) - For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate NA C403.5A ventilation / exhaust design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate systems exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by >_ 50% based on delta between OSA and return air enthalpies at design conditions For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to NA C403.2.7.2 Laboratory exhaust systems pre -condition laboratory make-up air; ER effectiveness (min 256F); or alternative method per (energy recovery) exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER C404.10A Pools and permanent spas method and use of waste heat (preheat ventilation air, pool water or service hot water); or NA (under exhaust systems exception taken C404.11) (energy recovery) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by > 360F For buildings with on -site steam heating systems, indicate condensate water ER NA C403.5.2 Energy recovery - steam condensate systems For buildings that use off -site generated steam where condensate is not returned to the source, indicate on -site condensate water ER I 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 9 of 20 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includinq R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: SantiagoS-299 Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable Code Section Code Provision Information Required - Mustbe in permit documents Location in Building Department (yes,no,na) Documents Notes For buildings with food service, meat or deli departments that have >_ 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) NA C403.5.3 Energy recovery - cooler / freezer condensers For buildings with >_ 40,000 sf conditioned floor area and with i 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating For buildings with 24-hour operation and with > 1,500,000 Bluth of heat rejection capacity and NA C403.5A Energy recovery - design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service condenser systems water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 850F). Hydronic System Controls For hydronic system pump motors >_ 7.5 hp, indicate method of variable now control (VSD or equivalent method that requires ? 30 % design wattage at 50% design fluid flow); note NA C403.2.13 Variable flow control - exception taken C403.4.2.7 hydronic system pumps Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chilled water systems >_ 300,000 Btu/h, indicate systems are configured to automatically reset supply water temperature based upon demand; or exception taken. NA C403.2.5 Hydronic system setback If system pump motor hp z 3 hp, also indicate controls automatically reduce flow by >_ 50%. C403,4.2.4 and part load controls For chilled water systems (>_ 300,000 Btu/h, pump motor hp >_ 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open, or to maintain a minimum differential pressure; or exception taken NA C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers For cooling equipment with hot gas bypass, provide either multiple step unloading or NA C403.4.6 Hot gas bypass limitation continuous capacity modulation; indicate bypass capacity per Table C403.4.6 Two -pipe changeover Indicate changeover deadband (min 150F), heating / cooling mode scheduling and NA C403.4.2.2 systems changeover temperature range (limit 30°F) Chiller / boiler plant pump Indicate controls are configured to automatically reduce overall plant flow and shut-off flow NA C403.4.2.6 isolation through individual chillers and boilers when not in use For cooling towers with fan motors z 7.5 hp, indicate VSD and method to adjust fan speed C403.2.13.1.1 (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat NA C403.4.3.1,1 Heat rejection equipment - rejection device) C403.4.3.1.2 variable flow control For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison Heat rejection equipment - Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all NA C403.4.3.3 cooling tower flow turndown cells can be run in parallel Water loop heat pump - Indicate capability of central equipment to provide minimum 20OF water supply temperature NA C403.4.2.3.1 deadband deadband between heat rejection and heat addition modes; or exception taken Water loop heat pump - Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method NA C403.4.2.3.2.1 heat rejection equipment, used to limit system heat loss when heat rejection is not needed Zone 4 Water loop heat pump - For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling NA C403.4.2.3.2.2 heat rejection equipment, tower and heat pump loop Zone 5 Water loop heat pump - For hydronic heat pump systems with total system power > 10 hp, indicate 2-way isolation NA C403.4.2.3.3 isolation valves valves on each heat pump and variable flows stem control Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 For buildings with office, retail, education, library and fire station spaces, identify these spaces C403.6 Dedicated outdoor air on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; NA C403.6.3 systems or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting NA C403.6.1 Energy recovery ventilation calculations. Indicate ER rated effectiveness that increases OSA enthalpy by z 50 /o based on with DOAS delta between OSA and return air enthalpies at design conditions. Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is NA C403.6.2 Heating / cooling system configured to turn down, when there is no call for heating or cooling in the zone they serve controls with DOAS If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cm in equipment schedule 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 10 of 20 9M 5 1Alaehinntnn Cfatc Fnarnv Rode Fnrms for Rnmmercral Ruildinns includinn R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: SantiagoS-299 Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable Location in Building Department Code Section Code Provision Information Required - Must be in permit documents Documents Notes (yes,no,na) Increased prescriptive NA C402A 1.4 maximum vertical Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 C403.6 fenestration area with DOAS Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) Building provided with To comply with additional efficiency package option, indicate that 90 % or more of all occupied, NA C406.6 DOAS conditioned spaces are served b a DOAS per C403.6 Multiple Zone Air Systems Identify supply air systems serving multiple zones and the zones they serve on plans; indicate NA C403.4.4 Air systems serving multiple whether system is VAV and method of primary air control; or provide supporting zones documentation for applied exception to VAV Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and types VAV systems serving For each air terminal include: maximum airflow rates for primary supply air during zone peak NA C403.4.4 heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; multiple zones minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62A multiple zone equation is basis for minimum flow rates, provide calculation on plans Single duct VAV terminal Indicate single duct terminal units are configured to reduce primarysupply air before reheating NA C403AAA units or recooling Dual duct systems - terminal For systems with separate warm air and cool air ducts, indicate terminal units are configured to NA C403.4.4.2 units reduce the flow from one duct to minimum before mixing with air from the other duct Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is <_ 1.2 inch w.g. VAV system static C403AAApressure For systems with zone level DDC, indicate controls are configured to monitor zone damper NA C403.4.1.2 sensors - sensors and DDC set points positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic Multiple -zone VAV system For systems with zone level DDC controls, indicate controls are configured to automatically NA C403.4.4.3 ventilation optimization reduce outdoor airflow in response to changes in system ventilation efficiency; or exception controls taken Indicate controls automatically reset supply air temperature in response to building loads or NA C403AAA VAV system supply air reset outdoor air temperature; or exception taken Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions C403.71 Indicate system is configured for 100% air economizer operation and complies with all related NA Item 1 Air economizer economizer requirements per C403.3 (without economizer exceptions) C403.73 Provide DDC controls for all components of system; identify all DDC system input / output NA Item 2 Direct digital controls (DDC) control points; indicate capability for trending and graphical display For systems with minimum OSA> 2,500 cfm, indicate outdoor airflow monitoring station that C403.71 Outdoor airflow measures OSA intake under all load conditions; indicate control sequence that increases or NA Item 3 measurement and reduction reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) C403.7, For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station NA Item 4 Supply airflow measurement capable of measuring supply air delivered to VAV terminals under all load conditions Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, NA C403.7, Zone isolation and whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are Item 5 maximum area served expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 C403.7, Interior / exterior zone Verify that VAV terminals serving interior cooling driven loads are sized per design supply air NA Item 6 design supply air temperature that is 50F higher than VAV terminals serving exterior zones temperature Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in NA C403.71 Maximum air terminal inlet equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 Item 7 velocity fpm C403.7, Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC NA Item 8 Sequence of operation 36 C403.71 Maximum allowable system Verify fan system bhp is:5 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), NA Item 9 brake horsepower provide MECH-FANSYS form for each system Indicate all series and parallel terminal fans have electronically commutated motors; indicate C403.71 Fan -powered terminal unit DDC control system is configured to vary air terminal fan speed as a function of the load; NA Item 10 motor and control indicate fan speed during periods of low heating, low cooling, or ventilation only is15 66% of peak design airflow or provide supporting documentation for applied exception 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 11 of 20 201.5 Washinntnn State Fnernv Code Comoliance Forms for Commercial Buildings includina R2 & R3 over 3 stories and all R9 Revised January 2011 Project Title: SantiagoS-299 Date 1/1/2015 The following information Is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes C403.73 Application of single duct Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter NA Item 11 and fan -powered terminal zones with envelope loads; verify all other zones are served by single duct terminal units units Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint NA C403.7, Fan -powered terminal unit of all fan -powered terminal units to the minimum required to maintain ventilation during Item 12 primary air reset occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction For spaces > 150 sf with occupant density >_ 25 people 11000 sf, indicate space is served by a C403.71 High occupancy space dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also NA Item 13 controls indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by >_ 5°F For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, C403.7, indicate spaces are served by independent HVAC systems that are separate from HPVAV NA Item 14 Dedicated HVAC systems systems serving rest of building; systems have air economizer y g g; indicate dedicated HVAC controls or energy recovery per C403.3 Exception 9 Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas -fired boiler(s) with thermal C403.7, efficiency >_ 90%, air -to -water heat pumps, or heat recovery chillers NA Central plant efficiency Item 15 If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is s 20 % of total plant capacity, or provide thermal storage sized fors 20% of total plant capacity Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to NA C403.7, Fault detection and land monitor operation and provide fault reporting of required parameters for all VAV air handlers Item 16 diagnostics VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of NA C409.3.1 HVAC equipment energy The all equipment used to provide space heating and cooling, dehumidification and ventilation will use metering provided per C409; indicate equipment eligible for exception Documentation and System Specific Requirement To Support Commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; Scope of mechanical NA C408.2 systems commissioning For buildings with z 240,000 Btu/h total output cooling capacity or >_ 300,000 Btu/h total output healing capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 C403.2.10 C408.1.1 Commissioning including: narrative description of activities, responsibilities of the Cx team, schedule of NA C408.1.2 requirements in construction activities including verification of project close out documentation per C103.6, and conflict of C408.1.4.2 documents interest plan (if required); C103.6 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances NA C408.2.2 Air system and hydronic defined in the specifications; indicate systems shall be balanced in a manner to first minimize system balancing throttling losses, then adjusted to meet design flow conditions Air system balancing Indicate devices that provide the capability to balance all supply air outlets, zone terminals and NA C408.2.2.1 devices air handling equipment requiring system balancing Hydronic system balancing Indicate devices that provide the capability to isolate, balance and measure flow across all NA C408.2.2.2 devices hydronic equipment requiring system balancing including heating and cooling coils and pumps Functional performance Identify in plans and specifications the intended operation of all equipment and controls during NA C408.2.3 testing criteria all modes of operation, including interfacing between new and existing -to -remain systems Project Close Out Documentation Indicate in plans that project close out documentation and training of building operations and project personnel is required for all mechanical components, equipment and systems governed by Yes C103,6 rDnn mittal this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 12 of 20 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: SantiagoS-299 Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions, Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes Equipment - Sizing, Performance and Type SWH equipment type and Provide equipment schedule on plans indicating type and capacity; indicate efficiency complies Yes C404.2 efficiency with required federal standard S-321S-33 For individual SWH equipment serving an entire building with >_ 1,000,000 Btu/h capacity, indicate thermal efficiency t 90%; or exception taken For buildings with aggregate capacity of all SHW equipment >_ 1,000,000 Btu/h (exclude < NA C404.2.1 High input -rated SWH 100,000 Btu/h equipment from threshold calculation), indicate average capacity weighted systems thermal efficiency >_ 90%; or exception taken If applying Exception 1 for site -solar or site -recovered energy, provide calculations and source of annual service water heating energy use estimate Yes C404A Heat traps Indicate piping connected to equipment have heat traps on supply and discharge S-321S-33 Insulation under electric For electric water heaters located in unconditioned spaces or on concrete floors, indicate R-10 NA C404.5 I water heater insulation under equipment Piping Systems Indicate thickness of piping insulation on plans per Table C403.2.9; verify insulation is provided Yes C404.6 Insulation of piping - from the water heater to the final fixture in a line, from the inlet / outlet piping at water heater to heat trap (up to 8 feet), and on piping that is heat traced; note exceptions taken S-323S-33 Indicate method of compliance on plans for all piping runs connecting service hot water source Yes C404.3 Efficient SWH supply piping to hot water fixture (maximum pipe length or maximum pipe volume method per Table C404.3.1); provide calculations for all piping runs documenting the total length and / or volume S-32,S-33 Service Water Heating System Controls For circulation systems with dedicated return piping, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand and when the desired water temperature is met C404.7.1 Heated -water circulating NA C404.8 systems For circulation systems with cold water supply piping serving as the return, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand, or when temperature of water entering the cold water supply pipe is >_ 104°F For heat trace systems provided to maintain temperature of service hot water in piping, NA C404.7.2 Heat trace system controls indicate controls are configured to de -energize system when there is no demand for hot water and when the desired water temperature is met Controls for hot water For systems with separate water heater and storage tank, indicate controls are configured to NA C404.7.3 storage limit operation time of pump after end of heating cycle to s 5 minutes For SWH, pool / spa and pressure boosting pump motors > 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires;!: 30% design wattage at 50% design NA C403.2.13 Variable flow control - fluid flow); note exception taken C403.4.2.7 pumps Identify basis of pump speed control (differential or static pressure setpoint, pressure, zone load demand, etc Pools and Permanent Spas - Equipment and Controls (Sections are under C404.11) Provide equipment schedule on plans indicating type and capacity for all pool heating NA C404.10.1 Pool heating equipment equipment; indicate efficiency complies with required federal standard; for heat pump water efficiency heaters indicate COP >_ 4 NA C403.2.13 flow control - Refer to Service Water Heating System Controls pumpse C404.10.1 Indicate automatic on / off control based on scheduling and readily accessible on / off switch NA C404.10.2 Pool heater on /off controls on heater that operates independent of thermostat setting; note exceptions taken For all pools and in -ground permanent spas, indicate a vapor retardant cover on plans NA C404.10.3 Pool covers For all pools and in -ground spas heated to > 900F, indicate cover shall include insulation i R- 12 For all pools and in -ground spas heated to > 90°F, Indicate on plans that sides and bottom are NA C404.10.3 Pool assembly insulation provided with insulation z R-12 NA C404.12 Energy consumption of Indicate portable spa complies with Association of Pool and Spa Professionals APSP-14 portable spas 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 13 of 20 Energy Recovery (ER) Systems - Service Water Heating and Pool Systems For buildings with pools or permanent spas with water surface area > 200 sf, indicate exhaust C404.10.4 Pools and permanent spas air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); NA (Section exhaust systems or exception taken under C404.11) (energy recovery) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by >_ 36°F For buildings with food service, meat or deli departments that have >_ 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat NA C403.5.3 Energy recovery - service water cooler / freezer condensers For buildings with >_ 40,000 sf conditioned floor area and with >_ 13000,000 Btulh of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water For buildings with 24-hour operation and > 1,500,000 Btu/h of heat rejection capacity and Energy recovery - design SWH load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or NA C403.5A condenser systems exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 850F). Drain water heat recovery For systems incorporating drain water ER, indicate system design complies with CSA B55.2 NA C404.10 units (or CSA 55.1 for Group R); indicate potable waterside pressure loss at design flow is < 10 psi Service Water Heating Energy Use Metering SWH energy usage in For Group R-2 multi -family buildings with central SWH systems, provide metering of hot water NA C404.9 dwelling units energy usage per dwelling unit; indicate metering and data reporting method For new buildings > 50,000 sf and building additions > 25,000 sf, with total SWH equipment NA C409.3.2 SWH equipment energy use capacity >_ 50 kW ( z 170,600 Muth), vefiiy energy use metering of all SWH equipment will be metering provided per C409 Additional Efficiency Package Option, Reduced Energy Use In Service Water Heating - Must comply with both provisions to be eligible To comply with additional efficiency package option, verify that_ 90% of the conditioned floor area of the building is one or more of the occupancies identified in this section, OR; NA C406.7.1 Eligible building type Provide whole building energy analysis per C407 that demonstrates the SWH load in the building is >_ 10% of total building energy loads To comply with additional efficiency package option, provide documentation that verifies >_ 60% of building annual SWH energy is provided by high efficiency sources (heat pump water heater with COP >_ 3, waste heat recovery, solar water -heating system); NA C406.5.2 Load fraction For buildings with 24-hour operation and with > 1,500,OOD Btu/h of heat rejection capacity and - C403..4 design service hot water load > 250,000 Btu/h (per C403.5.4); provide documentation that verifies t 100% of building annual SWH energy is provided by condenser energy recovery or other high efficiency source Documentation and Specific System Requirements to Supporting Commissioning Indicate that all SWH equipment and controls for which the WSEC requires control functions Scope of service water and / or configuration to perform specific functions are required to be commissioned;+D7 NA C408A heating systems For buildings where the largest SWH system has ? 200,000 Btu/h total output capacity, commissioning indicate that all SWH systems regardless of individual capacity are required to be commissioned. Indicate that all pool and permanent spa water heating systems regardless of individual capacity are required to be commissioned; Scope of pool and Indicate that energy recovery equipment that heats pool water regardless of capacity is NA C408.4.1.3 permanent spa systems required to be commissioned; commissioning Identify all pool heating and energy recovery equipment and controls that the WSEC defines as being capable of and / or configured to perform specific functions. Indicate in plans and specifications that Cx per C408 is required for all applicable service water heating systems; C404.13 Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 C408.1.1 Commissioning including: narrative description of activites, responsibilities of the Cx team, schedule of NA C408.1.2 requirements in construction activities including verification of project close out documentation per C103.6, and conflict of C408A A2 documents interest plan (if required); C103.6 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. Functional performance Identify in plans and specifications the intended operation of all equipment and controls during NA C408.4.1 testing criteria all modes of operation, including interfacing between new and existing -to -remain systems Project Close Out Documentation Indicate in plans that project close out documentation and training of building operations Documentation and project personnel is required for all SWH components, equipment and systems governed by this NA C103.6 close out submittal code; indicate close out documentation shall include: record documents, O&M manuals, requirements applicable WSEC compliance forms and calculations