Loading...
HomeMy WebLinkAboutPermit File BLD-2019-0511 1715 O Avenue (6)F1'dalgo IN= 6-,) tr e e t w GENERAL NOTES: 1. WORK HOURS: THE CITY OF ANACORTES ORDINANCE ALLOWS WORK FROM 7:00 AM TO 10:00 PM, SEVEN DAYS A WEEK (COA ORD. #2316). SOMEONE IN CHARGE SHALL BE ON -SITE AT ALL TIMES WHEN WORK IS IN PROGRESS. IF WORK IS DONE ON WEEKENDS, PLEASE INFORM THE PROJECT MANAGER SO THE CITY OF ANACORTES CAN HAVE AN INSPECTOR ON -SITE. CONTRACTOR WILL BE BILLED FOR CITY OF ANACORTES OVERTIME. 2. CALL 48-HOURS BEFORE THE FOLLOWING: FOR INSPECTION CONTACT 360.299.1951. A. PRIOR TO WORK START UP. B. PRIOR TO ANY UTILITY CONSTRUCTION IN THE RIGHT-OF-WAY. C. PRIOR TO POURING CAST -IN -PLACE CONCRETE STRUCTURES. D. PRIOR TO PLACING ANY CRUSHED ROCK ON ROADWAY SUBGRADE. E. PRIOR TO PLACING CURB, GUTTERS AND SIDEWALKS. F. PRIOR TO ASPHALT PAVING. 3. MATERIALS AND WORKMANSHIP: A. ALL MATERIALS USED, MUST MEET WSDOT, APWA AND CITY OF ANACORTES SPECIFICATIONS B. ALL WORK AND MATERIALS THAT DO NOT MEET THE ABOVE SPECIFICATIONS, MUST BE REMOVED AS DIRECTED BY THE PROJECT INSPECTOR. C. SUBGRADE COMPACTION TESTS: WILL BE DONE BEFORE AN C.S.B.C. IS PUT IN PLACE, ALL TRENCHES WILL BE TESTED FOR COMPACTION. THE MATERIAL TESTING LAB NEEDS 24-HOUR NOTICE. USE THE TESTING PROTOCAL PROVIDED BY THE CITY. ITEMS TO BE COMPACTION TESTED WILL INCLUDE THE PIPE BEDDING (SECTION 7-08.3(1)C), BACKFILL SECTION 7-08.3(3) AND SUB -GRADE FOR SURFACING (SECTION 2-06.3(2) AND ASPHALT SECTION 5-04.3(10)B). D. INSPECTIONS: ALL ASPECTS OF THIS PROJECT WILL BE INSPECTED INCLUDING PIPING, BACKFILL, SUB -GRADE, CONCRETE AND ASPHALT, AS WELL AS FORMS, CURB, GUTTER AND SIDEWALK. IF A PORTION GETS BACKFILLED BEFORE INSPECTION, THE CONTRACTOR WILL DIG UP THAT PORTION FOR INSPECTION. 24-HOUR NOTICE REQUIRED. KNOW THE SCHEDULE AND LET THE CITY KNOW. E. TESTING PROTOCAL: PRIOR TO CONSTRUCTION, A PROCTOR AND SIEVE ANALYSIS SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE CITY OF ANACORTES ON ALL MATERIAL USED IN THE RIGHT-OF-WAY. SEE THE CITY OF ANACORTES TESTING SCHEDULE. F. ALL COMPACTION TEST SHALL BE APPROVED BY THE CITY OF ANACORTES ENGINEER AND PROJECT MANAGER PRIOR TO PLACING OF CRUSHED SURFACING, ASPHALT, CURB, GUTTER AND SIDEWALK (INCLUDING TRENCH RESTORATION WHEN TEST MAY BE REQUIRED IN EACH LIFT). G. CITY OF ANACORTES MAY REQUIRE ADDITIONAL TESTS ON SUBGRADE, TRENCHES, CONCRETE, OR ASPHALT. THE COST OF TESTING SHALL BE PAID FOR AS INDICATED IN THE CONTRACT DOCUMENTS. 4. TRAFFIC CONTROL AND PUBLIC SAFETY: A. FLAGGING: ALL FLAGGERS MUST HAVE FLAGGING CERTIFICATES AND MUST HAVE ATTENDED A FLAGGING COURSE OR AN OFF -DUTY POLICE OFFICER IS REQUIRED. THE JOB WILL BE SHUT DOWN IF ANY UNCERTIFIED PEOPLE ARE FLAGGING. A STOP WORK ORDER WILL BE GIVEN AND WORK WILL NOT PROCEED UNTIL A CERTIFIED PERSON IS FLAGGING. B. SIGNAGE: ALL SIGNAGE MUST BE PER THE MANUAL UNIFORM TRAFFIC DEVICES. BEFORE THE JOB IS TO BEGIN, PROPER SIGNAGE WILL BE IN PLACE WITH FLAGGERS IN PLACE IF NEEDED. EXTRA SIGNAGE MAY BE NEEDED. BE READY TO RENT SIGNS IF NEEDED. C. TRAFFIC CONTROL PLAN: NEEDS TO BE SUBMITTED AND APPROVED BY THE PUBLIC WORKS DIRECTOR PRIOR TO CONSTRUCTION START. TRAFFIC CONTROL PLAN SHALL INCLUDE THE LOCATION OF SIGNAGE, FLAGGERS, WORK ZONE, SAFE ZONE, AND TRAFFIC FLOW AND NEEDED DIMENSIONS. NO DETOURS ALLOWED WITH APPROVAL FROM THE PUBLIC WORKS DIRECTOR. D. FOR STREET CLOSURE: CALL 911 OR FOR CELL PHONES, CALL 360.336.3131. E. CONSTRUCTION SAFETY: IS THE RESPONSIBLITY OF THE CONTRACTOR. 5. ROADWAY EMBANKMENT AND SUBGRADE CONSTRUCTION: A. CRUSHED SURFACING SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY. NO RECYCLED MATERIAL ALLOWED. B. EMBANKMENT AND SUBGRADE MUST BE COMPACTED TO 95% OF MAXIMUM DENSITY. C. PROPER MOISTURE MUST BE MAINTAINED THROUGHOUT PLACING AND COMPACTING. D. COMPACTION TESTING TO BE PERFORMED BY AN INDEPENDENT LAB. USE A "MODIFIED PROCTOR". 6. TRENCHES IN DEVELOPED RIGHT-OF-WAY: SEE CITY OF ANACORTES STANDARD CONSTRUCTION DETAILS AND SECTION 7 OF THE CURRENT WSDOT SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION. A. PIPE ZONE SHALL BE COMPACTED TO 90% OF MAXIMUM DENSITY. B. TRENCH ZONE SHALL BE COMPACTED TO 95% FO MAXIMUM DENSITY IN 12-INCH LIFTS. C. CRUSHED SURFACING SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY. NO RECYCLED MATERIAL ALLOWED. 7. A. ANY PERMANENT FLOW CONTROL FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE FACILITY IS TO FUNCTION AS AN INFILTRATION SYSTEM, THE TEMPORARY FACILITY MUST BE GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE (3) FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. B. OVERFLOWS, SPILLWAYS, GRAVEL FILTER WINDOWS, MUST BE CONSTRUCTED PER PLANS AND SPECIFICATIONS. NO DEVIATIONS. AS -BUILT FOR VERIFICATION REQUIRED. C. QUARRY ROCK MUST BE SOUND "HARD" DURABLE ROCK. NO RECYCLED MATERIAL. D. GRASS LINED SWALES SHALL BE CONSTRUCTED PER THE DETAILS PROVIDED. NO DEVIATION ALLOWED. ALL SWALES MUST BE OPERATIONAL BEFORE ACCEPTANCE. E. CATCH BASINS MUST BE SET TO LINE GRADE USING NO MORE THAN TWO (2) ADJUSTMENT BRICKS. F. MINIMUM 1-FOOT SEPARATION BETWEEN PIPES IN TYPE II CATCH BASINS. 8. RESTORATION OF RIGHT-OF-WAY: A. CONTRACTOR MUST LEAVE THE RIGHT-OF-WAY, EQUAL TO EXISTING OR BETTER CONDITION. B. PLACE COMPACTED TOPSOIL (SECTION 9-14.1(1), (2) AND (3)) AND SEED ALL AREAS DISTURBED BY EXCAVATION. (SECTION 9-14.2) C. ALL DRAINAGE SYSTEMS MUST BE FULLY CLEANED, RESTORED AND OPERATIONAL BEFORE FINAL ACCEPTANCE. (SECTION 7-07.3) 9. FINAL INSPECTION AND ACCEPTANCE: SEE SECTION 1-05.1 1 AND SECTION 1-08.5 A. WHEN THE CONTRACTOR HAS COMPLETED ALL OF THE WORK ON THE APPROVED PLANS, THE CONTRACTOR WILL: - COMPLETE THE "FINAL INSPECTION GUIDELINES FOR CONTRACTORS INSPECTION FORM". - GIVE THE COMPLETED "FINAL INSPECTION GUIDELINES FOR CONTRACTORS INSPECTION FORM" TO THE PUBLIC WORKS INSPECTOR AND REQUEST A SITE INSPECTION. ALL SITE INSPECTIONS ARE ON WEDNESDAY BETWEEN 9 AM TO 12 PM. B. THE PROJECT MANAGER, ENGINEER OF RECORD, INSPECTOR, CONTRACTOR AND OTHER CITY OF ANACORTES DEPARTMENTS WILL WALK THE SITE AND CREATE A PUNCH LIST. THE CONTRACTOR WILL COMPLETE THE PUNCH LIST AND CHECK OFF EACH ITEM, THEN RETURN IT TO THE INSPECTOR FOR REINSPECTION. THE INSPECTOR WILL VERIFY THAT ITEMS ON THE WALK THROUGH ARE COMPLETED. C. THE CITY WILL NOT MAKE THE FINAL INSPECTION UNTIL THE PHYSICAL WORK REQUIRED BY THE CONTRACT AND APPROVED PLANS, INCLUDING FINAL CLEAN-UP AND ALL WORK ORDERED BY THE PROJECT MANAGER, HAS BEEN COMPLETED. (SECTION 1-05.11) D. FINAL APPROVAL OF THE PROJECT WILL NOT BE GRANTED UNTIL "AS-BUILTS" OR "DRAWING OF RECORD" (BOTH DIGITAL AND HARD COPY) HAVE BEEN RECEIVED AND APPROVED BY THE PROJECT MANAGER. E. THE CONTRACTOR MUST FURNISH ALL DOCUMENTATION REQUIRED BY LAW, TO ALLOW THE CITY OF ANACORTES TO PROCESS FINAL ACCEPTANCE OF THE CONTRACT. 10. MISCELLANEOUS: A. AS-BUILTS/DRAWING OF RECORD: REFER TO "GEN-13 - DRAWING OF RECORD". B. UTILITY LOCATE NUMBER: 1.800.424.5555. REQUIRED BEFORE STARTING ANY GROUND WORK. STORM DRAINAGE NOTES A. ALL WORK SHALL CONFORM TO THE CURRENT WSDOT SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, CITY OF ANACORTES DRAINAGE CODES AND ORDINANCES AND THE CITY OF ANACORTES ENGINEERING AND DEVELOPMENT STANDARDS. B. ALL POLY -VINYL CHLORIDE PIPE (PVC) AND FITTINGS SHALL CONFORM TO AND MEET THE REQUIREMENTS OF THE LATEST ASTM SPECIFICATION D3034. PIPE AND FITTINGS SHALL MEET STANDARD DIMENSION RATIO 35. PROVISIONS MUST BE MADE FOR CONTRACTION AND EXPANSION AT EACH JOINT WITH A RUBBER RING, SECURELY PLACED TO PREVENT DISPLACEMENT. C. ALL CONCRETE STORM PIPE SHALL BE RUBBER GASKETED, REINFORCED CONCRETE CULVERT PIPE CONFORMING TO SECTION 9-05.3(2) OF THE SAID APWA STANDARD SPECIFICATIONS. D. ALL CORRUGATED POLYETHYLENE PIPES (CPEP) SHALL BE SMOOTH INTERIOR AND MANUFACTURED FROM HIGH -DENSITY POLYETHYLENE RESIN, WHICH SHALL MEET OR EXCEED THE REQUIREMENTS OF TYPE III, CATEGORY 4 OR 5, GRADE P33 OR REQUIREMENTS OF AASHTO M249. ALL FITTINGS AND ACCESSORIES SHALL BE MANUFACTURED AND FURNISHED BY THE PIPE SUPPLIER. E. ALL 12-INCH THRU 36-INCH DIAMETER CORRUGATED POLYETHYLENE PIPE (CPE) FOR STORM SEWER AND CULVERTS SHALL COMPLY WITH THE REQUIREMENTS OF WSDOT/APWA SECTION 9-05.19 CORRUGATED POLYETHYLENE CULVERT PIPE. JOINTS SHALL BE SOIL -TIGHT. ALL 3-INCH THRU 10-INCH DIAMETER CORRUGATED POLYETHYLENE PIPE (CPE) SHALL COMPLY WITH ALL THE REQUIREMENTS OF AASHTO M252 AND BE MANUFACTURED WITH A SMOOTH INTREGRAL LINING THAT COMPLIES WITH ALL MATERIAL AND STIFFNESS REQUIREMENTS OF AASHTO M294. JOINTS SHALL BE SOIL TIGHT AS DEFINED IN SECTION 9-05.19. F. ALL FITTINGS SHALL BE OF LIKE MATERIAL AS THE PIPE FURNISHED BY THE PIPE SUPPLIER. G. ALL PIPES SHALL BE SUITABLE FOR USE AS A GRAVITY DRAIN CONDUIT. H. THE END OF THE ROOF AND FOOTING DRAIN STUB OUTS SHALL BE MARKED "STORM DRAIN" ON A PVC PIPE. I. THE MARKER SHALL EXTEND A MINIMUM OF 36-INCHES ABOVE THE GROUND. THE PORTION ABOVE THE GROUND SHALL BE LABELED "STORM SEWER" WITH BLACK LETTERS. IT SHALL ALSO IDENTIFY THE INVERT OF THE STUB. J. CLEAN -OUTS SHALL HAVE CAST IRON CASES. K. DRIVEWAY CULVERTS LOCATED WITHIN THE RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. L. FOOTING DRAINS, ROOF DOWN SPOUT AND CURTAIN DRAINS ARE TO BE CONNECTED TO THE STORM DRAINAGE OR SWALES AS SHOWN ON THE CONSTRUCTION PLANS. M. MINIMUM SLOPE ON ROOF AND FOUNDATION DRAIN STUBS SHALL BE 0.5% AND HAVE A MINIMUM OF 1-FOOT OF COVER. ROOF DRAINS AND FOUNDATION DRAINPIPES SHALL BE CONSTRUCTED OF PVC ASTM D3034 SDR 35, AND ASTM F679. N. DRAINAGE OUTLETS (STUB OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT. STUB -OUTS SHALL CONFORM TO THE FOLLOWING: - EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS, FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO RENDER LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE -FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORM WATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. - OUTLETS ON EACH LOT SHALL BE LOCATED WITH A SECTION OF PVC PIPE MARKED "STORM" ON THE END OF THE PIPE AND SHALL EXTEND 36-INCHES ABOVE THE GROUND. - DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. - THE ENGINEER/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB OUT CONVEYANCE LINES WITH RESPECT TO UTILITIES (E.G., POWER, GAS TELEPHONE, CABLE, ETC.) - ALL INDIVIDUAL STUB OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT OWNER. 0. CATCH BASINS AT THE CURB LINE SHALL BE RECESSED 0.1 FEET. P. ALL STORM DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES, NOT LOCATED WITHIN A TRAVELED, PAVED ROADWAY OR CONCRETE SIDEWALK, SHALL HAVE LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT DETENTION FACILITY SHALL HAVE LOCKING LIDS. ALL DRAINAGE STRUCTURES LOCATED WITH A BIKE OR WALKING PATH SHALL HAVE LOCKING LIDS. Q. ALL CATCH BASIN GRATES SHALL INCLUDE THE STAMPING "OUTFALL TO STREAM, DUMP NO POLLUTANTS". R. CATCH BASINS SHALL CONFORM TO TYPE 1, TYPE 11, OR THE INLET TYPE AS DEFINED IN SAID APWA STANDARD SPECIFICATIONS AND STANDARD PLANS WITH FLAT TOP FRAME AND GRATE. S. CATCH BASINS MUST BE SET TO LINE GRADE USING NO MORE THAN TWO (2) ADJUSTMENT RINGS. T. THE CAST IRON FRAME MAY BE PLACED FLANGE DOWN ON THE ADJUSTMENT BLOCKS IN LIEU OF PRECAST COLLAR. THE INSTALLATION OF CATCH BASINS SHALL INCLUDE FINAL ADJUSTMENT AS MAY BE REQUIRED TO FINISH GRADE. INSTALLATION WITH THE PAVED ROADWAY SHALL BE PER THE CITY OF ANACORTES TYPE I CATCH BASIN WITH 18-INCH BARRIER CURB DETAIL UNLESS SPECIFIED AS A THRU-CURB INLET. U. CAST IRON FRAME FOR TYPE I CATCH BASIN SHALL ACCOMMODATE; A 20-INCH X 24-INCH GRATE. V. A LOW PRESSURE AIR TEST AT 5 PSI FOR 15 MINUTES FOR SEWER MAINS IS REQUIRED. THE CITY OF ANACORTES MAINTENANCE CAMERA CREW WILL VIDEO SANITARY SEWER AND STORM SEWER MAINS. CALL 360.293.1921 TO SCHEDULE APPOINTMENT. 48-HOUR NOTICE REQUIRED. (SECTION 7-17.3(2)H). W. THE CONTRACTOR SHALL BE REQUIRED TO PLACE METALLIC TAPE OVER ALL NON-METALLIC PIPES. THE METALLIC TAPE SHALL BE A MINIMUM OF 2-INCHES IN WIDTH AND PLACED CONTINUOUSLY THE LENGTH OF THE STORM DRAIN TRENCH. X. ALL TRENCHES FOR STORM DRAINS SHALL BE IN ACCORDANCE WITH THE SECTION 7 OF THE CURRENT WSDOT SPECIFICATIONS FOR ROAD, BRIDGES AND MUNICIPAL CONSTRUCTION. Y. ANY PERMANENT FLOW CONTROL FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE FACILITY IS TO FUNCTION AS AN INFILTRATION SYSTEM, THE TEMPORARY FACILITY MUST BE GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE (3) FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. Z. OVERFLOW, SPILLWAY, GRAVEL FILTER WINDOWS MUST BE CONSTRUCTED PER PLANS AND SPECIFICATIONS. NO DEVIATIONS. AS -BUILT FOR VERIFICATION REQUIRED. AA. QUARRY ROCK MUST BE SOUND "HARD" DURABLE ROCK. NO RECYCLED MATERIAL. BB. GRASS LINED SWALE SHALL BE CONSTRUCTED PER THE DETAILS PROVIDED. NO DEVIATIONS ALLOWED. ALL SWALES MUST BE OPERATIONAL BEFORE ACCEPTANCE. CC. MINIMUM 1-FOOT SEPARATION BETWEEN PIPES IN TYPE II CATCH 9ASINS. DUST CONTROL NOTES 1. Dust control shall be maintained during construction by watering the construction road when and where truck traffic is concentrated. VICINITY PLAN SCALE: 1 "=300' 1. CITY OF ANACORTES: A. STEVEN LANGE: PROJECT MANAGER B. JUSTIN: PUBLIC WORKS INSPECTOR OFFICE: 360.299.1983 OFFICE: 360.299.1972 CELL: 360.661.3468 CELL: 360.661.3547 FAX: 360.293.1938 FAX: 360.293.1938 EMAIL: STEVEL®CITYOFANACORTES.ORG EMAIL: JIMBOCITYOFANACORTES.ORG C. ERIC SHJARBACK: ASSISTANT CITY ENGINEER OFFICE: 360.293.1920 FAX: 360.293.1938 THE PROJECT MANAGER IS THE KEY PERSON OF CONTACT FOR THE CITY OF ANACORTES REGARDING TECHNICAL AND ENGINEERING MATTERS. THE PUBLIC WORKS INSPECTOR IS THE KEY PERSON OF CONTACT FOR THE CITY OF ANACORTES FOR QUALITY ASSURANCE, SAFETY, FIELD COORDINATION AND INSPECTIONS. ANY OTHER CITY PERSONEL SHOWING IMPLIED AUTHORITY ON -SITE SHOULD BE DIRECTED TO THE PROJECT MANAGER. IF THE PROJECT MANAGER IS UNAVAILABLE, THE LINE OF COMMUNICATION SHOULD BE FOLLOWED. B. CITY OF ANACORTES WATER DEPARTMENT 2. ADDITIONAL CONTACT INFORMATION: TERRY NEMETH: FOREMAN OFFICE: 360.293.1921 A. CITY OF ANACORTES STREET DEPARTMENT BILL LARSEN: FOREMAN COMCAST CABLE OFFICE: 360.293.1921 Bill Inama, Construction Maintenance C. COMCAST CABLE CELL; 360-815-6354 CASEY JONES: NEW CONSTRUCTION 360-527-8302 EMAIL bill_inamaOcable.comcast.com EMAIL CELL: 425.508.7335 FAX: 360.527.8302 CASCADE NATURAL GAS EMAIL: CASEY-JONESOCABLE.COMCAST.COM Jim Hobbs D. CASCADE NATURAL GAS OFFICE: 360-336-3911 Ted McCommant CELL 360-941-0499 OFFICE: 360.336.3842, FAX: 360-336-2564 Cell: 360-708-4689 EMAIL james.hobbs®cngc.com FAX: 360.336.2564 p ENERGY SCHEDULE OF DRAWINGS Cl Cover Sheet, Vicinity Plan & Construction Notes C2 Existing Site Plan C3 Erosion Control Plan C4 Site Improvements Plan C5 Perk Filter and BMP Details C6 Details C7 Details EMAIL: ted.mccammantOcngc.com UGET SOUND CONSTRUCTION SEQUENCE Jane Major -Municipal Construction E. PSE/INTOLIGHT Planner Lane Mahler, Project Manager OFFICE: 360-766-5571 OFFICE: 425-462-3624 CELL 360-791-2748 1. CELL: 425-429-1356 EMAIL- Jone.majorOpse.com FAX: 425.462.3149 Frontrier 2. EMAIL:- lane.mahlerOPSE.COM Bret Murdock OFFICE: 360-707-0641 CELL 425-417-7085 FAX: 360-757-4338 EMAIL bret.t.rrurdock®ftr.com DEVELOPER COMPANY NAME: Madrona Real Estate Investors OWNER NAME: Brad Augustine OFFICE: 206-623-7662 CELL: FAX: EMAIL: BradcOMadronaRealEstate.com EERING FI COMPANY NAME: Herrigstad Engineering PS OWNER NAME: Dale Herrigstad OFFICE: 360-299-8804 CELL: 360-770-2585 FAX: EMAIL: dole®herrigstad.com NAME: James Sullivan OFFICE: 206-623-7662 Ext 107 CELL: 206-538-2951 FAX: EMAIL: JamesS®MadronaRealEstate.com MATERIAL TESTING COMPANY: COMPANY NAME: OWNER NAME: OFFICE: CELL: FAX: EMAIL: NAME: TBD OFFICE CELL EMAIL: .; INSTALL TEMPORARY EROSION CONTROL MEASURES. COMPLETE OFFSITE STORM WATER IMPROVEMENTS. PROJECT DATUM NAVD88 AT TOP OF SDMH RIM IN NE CORNER OF INTERSECTION NEAR CURB AT 18TH & "0" AVENUE. ELEV.=30.09' NAVD88 FIE UT Y PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anocortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of corn lionce with a plicable laws and permit requirements. III. 1`l.l CITY ENGINEER DATE The acceptance will expire one year from the date noted above. 16-2019 Rev. B, October 16, 2019 a Ono 21; O O _4 I 0 cQ CC 54 W CQ w o CQ z � a> it W � CO y O _ CO C ra CO W� 0 � � 4-) %1 0 SHEET NO. C1 REV.: B JOB NO: 2018-11 DATE: October 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRIGSTAD SHEET L OF EX. SSMH L-034 RIM=28,83' I.E,=15,73' SD I N 40,0' I l 28.3V 28,98'� I x 29,441- III Ss O O TYPE 2 SDMH RIM ELEV,=18,74' INV, OUT = 12' CONC. SDI SD SD w EXIST, TYPE1 CB RIM ELEV: 18,82' — — — — — — — — — — `� INV, OUT = 15.57' — d �i\i VL I I L1 O RIM=21,29' �r U I.E,=19,68' I 1 as as I CIS I — —�--- — — I F10 i B �fYPE1EXIST. 8" PI C SD EXI T. 8 PVC SD aI 9 IM=22,44' 7 I EX, CB 3 I 2RIM=19,,8iILE,=17,5SPARAEXIST. 8" P I 1 I > I I I I c I I EX, CB TY I 28,06' SS PAVED G I EX, CUR I EXIST. 8" j PVC SD IE 1�i 90' SD SD EX, CB TYPE'1- I I J�� �� 1 1 RIM=21,96' i INGRE7AF� �Ji I I.E,=20,81' EGRESI EX. SSMHI EASEM�� I L-034 1 j #9812SEE G ��~ I RIM=23,65' I I --- E=1�0-------- --- I---INFORMOIDN ----- -EXISTING ASPHALT EX. 8" PVC SS Z26,47'SS 25.41ss NITTE_97 T SH ENCLOSURE EX, URB r--------�--- —-------I------� GARAGE I 24,08' cc I I I I 23.88 HAVE 23.11' BEEN N L I I 1 REMOVED I � I z 0 I j 22.87 I q 1014 I I 7' SIDEWALK I HOUSE I ``'_ 18TH T. l I I I 1020 1 18TH ST,i 1 13 14 I I 15 I 2 4 I 1 1 , 19 1 20 I q 11 16 , 17 1 0 0 23.36 I x I L J I EXIST, TYPEI CB RIM ELEV.=19.71' INV, BUT = 17.49 SEXIST. 8" PVC SD 40,0' 40,0' 25� 6 — -- -- -- I Y WM PP11 26.7 ' EXIST. 6' SIDEWALK WM 7RIM=30,09 , S MH EX, FACE OF CURB 27,25' 6,71' 28 886' 27.72 �- 27,5' 18th STRE T 4,29, - - - S 89058'5V Q 379,63' W EX, 6" DI WATER W W GRAPHIC SCALE ( IN FEET ) 1 inch = 20 ft W 8" CMP SD sDSD '�--EX, CB TYPE1 a RIM=22,03' o I.E,=20Y21' u-� X TYPE1 CB a rTYPEl CB LEGEND FENCE —x x x x x— GAS c SANITARY SEWER ss STORM SEWER SD WATER MAIN W OVERHEAD POWER --oP----oP----oP----oa--- ERHEAD TELEPHONE --oT----aT----oT----oT--- SDCB ❑ SSCB 0 SSMH 0 WFH2 R WGV N WMET ED FDUND MONUMENT � WITH CASE & COVER 5-3-2014 V1 PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anacortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the Professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of com lionce with applicable laws and permit requirements. 'F-4- 1\•\9.\9 CITY ENGINEER DATE The acceptance will expire one year from the date noted above. D-16-2019 Rev, B, October 16, 2019 o I q� � o �j d �T V W W c� N a, I~ C j C\2 O� CD � O � O W � SHEET NO. C2 REV.: — JOB NO: 2018-11 July 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRIGSTAD 2 7 tt-��-�F� QazP4o,ww,•a-- TESC NOTES W HIGH VISIBILITY FENCE ALONG PERIMETER DOE BMP C103 40,0' EX. 5' SIDEWALK x I I x 'a Ix I x I x II a I x e I I LX, CB TYPEI RIM=22,44' Tr- —innnl PAVED 11 PARKING CONSTRUCTION ENTRANCE DOE x BMP C105 DOE FIGURE II-4.1.1.10 SAWCUT(on-o'64 EXISTING ASPHALT EX, 8' PVC S% 28,06' /26,47' EX. SSMH AWCUT� L-034 C P C152) RIM=28.83' I.E.=15,73' 28,31' x 29, 5' HIGH VISIBILITY FENCE x ALONG PERIMETER44 DOE BMP C103 OR CHAIN LINK FENCE " .d cn 00 28,98' x 00 q Z 0 ib X W U 09A4'j- T 30� EXIST, RIM=3C I.E.=24 P 55160 PARKING LOT WILL BE STABILIZED WITH CRUSHED SURFACING FOR CONSTRUCTION PARKING 1 APARTMENT 2733 BUILDING 4,432 SF 27,59' FLOOR RISER ELEV,=28,63' R00 2'^IRETAP59' f G a <a A — Q�q---X X —� 27,70' ra 25.4 26,93' 7,25' C�_X RIM=21,29' 1.E,=19.68' ST. 8" PVC SD EX. \CURB 3,11' 23.3 as aS EXIST. 8 PVC SD EX. CB TYPE1- RIM=19,94' IE,=OIL/ W/ OIL/WATER SEPARATOR EXIST. 8" PVC Q_ EX, CB TYf'­F-_1- EXIST. 8" PVC SD RIM=20,27' IE=1790' SD EX. CB TYPE1 — — SD — _ RIM=21,96' INGRESS/ I.E.=20,81' EGRESS CB INLET PROTECTION WITH EASEMENT AF WSDOT 1-40.20-00 #9812040003 INSERT FILTER SOCK(Em?e ) SEE GENERAL EX. SSMH INFORMATION L-034 RIM=23,65' NOTE 9, I,E.=16,0' 1710 COMMERCIAL AVE 11'x11' SEDIMENT TRAP DURING CONSTRUCTION SEE SECTION B-B BELOW (51y\P C'"o) SILT FENCE DOE BMP C233 DOE FIGURE BMP C154 CONCRETE WASHOUT AREA BMP C123 COVER SOILS STOCKPILES, -CONSTRUCTION JOB-SH,AUK — — 6' MH EX. FACE F CURB 27.25'�f�„ f' R 9 27,72' SAWCUT CONSTRUCTION ENTRY 9 28,86' _ 18TH STREET BMP C105 DOE FIGURE II-4.1.1. I(J_H VISIBILITY FENCE ALONG PERIMETER DOE BMP C103 w w EX. 6" DI WATER V w ti TRAP OUTLET SECTION C-C r E DOE EXIST. 6' SIDEWALK to HIM 7' SIDEWALK CB INLET PROTECTION WITH WSDOT 1-40.20-00 INSERT FILTER SOCK _ I 1' OVERFLOW DISHARGE TO STABILIZED 2'-4' n RIPRAP CONVEYANCE 31 SIDE SLOPE 3.5 'BOTTOM ELEV. 3:1 SIDE 1 = 285' SLOPE FLAT BOTTOM 3/4'-1,5' WASHED ROCK GEOTEXTILE TYPICAL TRAP CROSS SECTION B-B - ?-ky\� Gz°ix) SCALE: 1"=5' .l 1' MIN, DEPTH OVERFLOW SPILLWAY --,3/4'-1.5' GEOTEXTILE WASHED ROCK TRAP OUTLET SECTION C-C SCALE: 1'=5' GRAPHIC SCALE ( IN FEET ) 1 inch = 20 ft. EXIST. TYPE: CB I RIM ELEV,=19.71' INV. OUT = 17.49 I �—EXIST. 8" PVC SD 40,0' LLJ Q ,l u 400, 8" CMP S p EX. CB TYPE1 RIM=22,03' I.E.=20,21' A. A Certified Erosion and Sediment Control Supervisor is required, The ESC Supervisor dust have attended and Erosion and Sediment Control class within 3years from today's date. Must provide certification card, B, The Certified Erosion and Sediment Control Supervisor will oversee and be responsible for all erosion control, The facilities shall be inspected daily and maintained to ensure proper functioning, Written records shall be kept of weekly reviews and after every significant storm event of the ESC facilities during the wet season (October 1 to April 30), Monthly reviews during the dry season (May 1 to September 30). Written records shall be turned into the Project Manager or Inspector on a weekly basis at the weekly scheduled project meetings. C. Shall be in place per the approved set of plans prior to any construction start, D. The erosion control shall be inspected once a day and modified to meet the surrounding conditions as needed, E. Provide a sign displaying a 24-hour contact number and name of the ESC Supervisor, The letter size shall be a minimum of 2' letters, This shall be in place prior to construction start. Remember, the look of the sign will be a reflection of the Contractor and Developer and Development, F. The storm drain system and existing ditches shall be cleaned daily (Section 707,3), All drainage systems shall be cleaned to the acceptance of the City of Anacortes prior to acceptance of the project, G. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained during the duration of the project, Additional measures may be required such as wash pads to ensure that all paved areas are kept clean, No mud is allowed to enter onto City streets, H. Any soils exposed that will not be disturbed for two (2) days during the wet season or seven (7) days in the dry season shall be immediately stabilized with the approved ESC methods (seeding, mulching, plastic covering, etc,) I, Two (2) weeks prior to the beginning of the wet season (October 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one (1) week of the beginning of the wet season, A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted to the Project Manager, The Project Manager can require seeding in additional areas in order to protect surface waters, adjacent properties or drainage facilities, J, Penalties for an Erosion Control violation are subject to a $300 to $1000 fine under Chapter 17,66 - Penalties for Violation, Each day is considered a different violation, K, Remove all temporary erosion control measures when the site is landscaped and soils are stabilized, L. All Dewatering shall dischage into a sediment trap or sediment pond. M. The contractor is to provide to the city inspector their spill prevention program to be inplace during construction. N, A sign shall be posted at the pro jext site that complies with AMC chapter 17,40,060(E) regulating signage within the City of Anacortes, The sign shall advertise the name and phone number of the Contractor who is accessible 24/7 to handle complaints, 0, Work hours are limited to 7+00 AM to 10:00 PM, Sunday to Saturday. No work outside these hours are permited. 0 PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anocortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of compliance with applicable lows and permit requirements. Q,cc�pt�� /as uo� CITY ENGINEER DATE The acceptance will expire one year from the date noted above. D-16-2019 Rev, B, October 16, 2019 z 0 o q v� a I M CRC,P4� o rl�^l WQ� A �� cat CC E� M 04w Q4 W Cn W x�o �� W a) ~ f, a) .> a) -6-.) � W y �00 o +"--' C\2 ~ co Cn �GZ Cn O T Q c� O G� o ^r—� CJ o � 'n . 7=1 o � W� SHEET NO. C3 REV.: - JOB NO: 2018-11 DATE: Oct. 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRIGSTAD SHEET.!! —OF 40,0' I 6,5' S IV- z Q O DRIVEWAY EN Ct WSDOT STND PLAN F-60,10-03 TYPE 4 EX, SSMH --� L-034 RIM=28,83' I,E,=15,73' BMP T513 POST Mimi EXT�Vg2P Slpe IpL A1�r (� yd LJ� WILL.L-Al2— �r��pLk �S"t'v.N(�t�.eo A.-tit-� (Y-4o.15-031 �Mt%--•D Tb GIT'� �c�1�\R.�w1�7CS d- W EX. FIRE HYDRANT I O REMOVE EXIST, BLOCK I WALL TRASH ENCLOSURE Q QI `� I NEW SSMH O(NDOGHOUSE O USE MH) 47,5M15,8;o 18' S5 LF PVC STO BLDG WITH IRON LID - L SS — I CONSTRUCTION SOILS ON i ALL NEW GRASS AND LANDSCAPING AREAS. �Z r I � d X W SECTION A -A SHOWN BELOW PERPENDICULAR CURB­­,6,5 RAMP B WSDOT STND PLAN F-4015-03 — SEXIS , SDMH RIM= 0109' I,E,=2 ,29' 11 EXISTING 17th STREET W W W REMOVE NEW 5' STORM DRAIN EASEMENT EX. CB TYPEI ®r(2) WM RIM=21,29' CB TYPE1 I.E.=19,68' RIM=22,44' POLE REPLACE WITH 48 LF 12' CPEP SD SLOPE=0,005 FT/FT 180 LF 12' CPCP SD SLOPE=0,005 FT/FT W EX. 12' CONC. ST TYPE 2 SDMH EXIST, TYPEI CB RIM ELEV,=18.74' qr:�TYPEI CB x RIM ELEV.=18,82' rn co INV, OUT � 3 o WA VALVE EX, 12" AC WA EPLACE Tl C TYPEI CB EXIST�TYPE1 CBRIM=19,01' RIM ELEV,=19,01' I,E,=15,81' INV, OUT = 17.46I 0 1 — — INV,=18,47' - — - ` - - - - - - - POLE 12 LF 12 CPCP SD - -- as - - - - - - - _ SLOPE=,0050 ____ EX. CB TYPEI EXIST. 8 PVC SD EXIST. _ 13s LF 8" PVC SD S=1.51% EX, ____-- CB TYPEI PERKFILTER 1 RIM=22,44' I RIM=19,94' STEEL CATCH BASIN GIs walk IS %oe� ,E,=19,84' I I EPLACE NEW 5 WIDE STORM LE.=17,57' FOUR CARTRIDGE o vNOP� L�NoCti� Sw\Ol�h I I DRAINAGE EASEMENT OVER W/ OIL/WATER RIM = 19.94' I \T- LF 12' I EXISTING STORM LINE AND SEPARATOR I I.E. = 16,00' OUT C EP SD I Q LE, IN = 17,5 ' I NEW EXTENSION TO PARCEL EXIST. 8" PVC SD SL PE=0,005 I N I P55161 I I EX. CB TYPEI I i EX. CURB EXIST. 8" PVC SD RIM=20,27' I SD LE.=17,90 CB YPEI I I O —SEX. CB TYPE1 - - S—� - I RIM=21.96' INGRESS/ INV, B 86' I ��O ° I.E,=20,81' EGRESS EX, SSMH EASEMENT AF L-034 #9812040003 36 " `�,� RIM=23.65' CPEPF D ��~ I.E.=16,0' SEE GENERAL SLL0P� INFORMATION GA VALVE \ NOTE 9, �IAIl_1}(. 8' PVC SS i—�- 21, S S C,O, GAS POWER METER METERS MOM L �i - \ ' \ 1 C 1BELOW V 21' 01 19, CU o \ 10' �—� 27,2 26,93' 7,06' 2' RETAIS91 SJI}EWALK 27,70' Ly rWM 8,5' PF EX. FACE OF CURB '- 19' -' DRIVEWAY ENTRANCE WSDOT STND PLAN -PROVIDE 18 T H S T R E E T F-80,10-03 TYPE 4 INV: 28,63' ELEV� 19, 41' 'A PARTMENT BUILDING 21.33 00 27,59'- 4C co,432 SF FLOOR RISEI ELEV,=88,63' ROOM SIDEWA K GUY' WIRE O ER SIDEWAL W I"* EX 6" DI WATER W REMOVE WATER METER AND DISCONNECT AT MAIN 4' WATER TAP FOR FIRE REMOVE WATER METER SURVICE LINE AND DISCONNECT AT W/ 4' DI VALVE MAIN AND 2' TAP FOR DOMESTIC WATER LINE WATER METER SIZE TO BE DETERMINE BY CITY SCALE: 1'=20' HORIZONTAL/ 1'=10' VERTICAL EXTRUDED CURB I I 1710 COMMERCIAL AVE GRAPHIC SCALE W Q 40,0' EXIST. 6' SIDEWALK I w B SCALE: 1'=20' HORIZONTAL/ 1'=10' VERTICAL // 8" CMP D s� '--EX, CB CB TYPEI RIM=22.03' I.E.=20.21' LEGEND FENCE GAS SANITARY SEWER SS - STORM SEWER SD WATER MAIN W OVERHEAD POWER —OP — — — — OP — — _RHEAD TELEPHONE — pT — — — — OT — — SDCB ❑ SSCO a SSMH WFH2 A WGV D4 WMET ES CURB/GUTTER AND SIDEWALK WORKMANSHIP AND AESTHETICS 1. CURB/GUTTER AND SIDEWALK CONSTRUCTION SHALL FOLLOW A TRUE AND UNIFORM HORIZONTAL AND VERTICAL ALIGNMENT. 2. THE VERTICAL AND HORIZONTAL SURFACE SHALL BE A SMOOTH BROOM FINISH WITH NO DETECTABLE FINISHING BLEMISHES, UNDULATIONS, RIPPLES, SWELLS, WAVES, RUTS, FURROWS, GRAFFITI OR OTHER OBJECTIONABLE MARKS. THE END RESULT SHALL BE A NEAT AND PROFESSIONALLY FINISHED APPEARANCE. 3. THE EDGE FINISH ADJACENT TO THE EXPANSION JOINT MATERIAL SHALL BE CLEAN AND FREE OF EXCESS SLURRY. THE EXPANSION JOINT MATERIAL SHALL BE TRIMMED TO A LEVEL EVEN WITH THE ADJACENT CONCRETE RESULTING IN A NEAT AND PROFESSIONALLY FINISHED APPEARANCE. 4. THE CITY ENGINEER IN HIS SOLE DISCRETION RESERVES THE AUTHORIY TO ORDER THE REMOVAL OF SECTIONS OF CURB/GUTTER AND SIDEWALK THAT DO NOT MEET THE WORKMANSHIP AND AESTHETIC STANDARDS OF THE CITY OF ANACORTES. 5. SECITONS OF NEWLY CONSTRUCTED CURB/GUTTER AND SIDEWALK THAT EXHIBIT CRACKING FOLLOWING THE CURING, SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT. - CRACKING RESULTING FROM SUB -BASE FAILURE OR CONSTRUCTION SITE DAMAGE SHALL BE IMMEDIATELY REMOVED AND REPLACED TO THE NEAREST EXPANSION JOINT. - MINOR HAIR LINE STRESS CRACKS MAY, AT THE DISCRETION OF THE PROJECT MANAGER, BE MONITORED AND RE-EVALUATED FOR POSSIBLE REMOVAL AT THE END OF THE MAINTENANCE PERIOD. FOUND MONUMENT WITH CASE ___7 / 3�p(�vES'r ��KII-16 SPvcES Tb Fes. �vlo� d.La-lV �b iSJt�.,uE., �7� L I`1.(�1 p36 - b40- �rC �ill_DIN% F�mcC SITE F1 l A7..0) SIoN (I.OS-19 I PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anacortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of compliance with applicable laws and permit requirements. A�-r�-e as Now - � I1 IS.I�i UITY ENGINEER DATE The acceptance will expire one year from the date noted above. 14-2019 Rev,C, November 14, 2019 �. o � I q W a cQ a o � ao� Cn F� cf I w� W x�o o � W m a> a O^ � � rrTT� O SHEET NO. C4 REV.: - JOB NO: 2018-11 DATE: Oct 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRIGSTAD SHEET 4 OF 7 w E— Q h PLAN VIEW (INTERNALS NOT SHOWN FOR CLARITY) SCALE 314' - V-0' e1e'XY DEEP KNOCKOUT -TO BE REMOVED BY CONTRACTOR FOR PIPING DO NOT USE THIS END KNOCKOUT ra 4' VIEW D (INTERNALS NOT SHOWN FOR CLARITY) SCALE 3W = T-O' N STAII WEIR WALL STAINLESS STEEL BAFFLE HOOD PIPE TO BE FULLY GROUTED AFTER INSTALLATION STAINLESS STEEL n WEIR WAIL on NOT USE THIS END KNOCKOUT DO NOT USE THIS END KNOCKOUT SECTION F-F (INTERNALS) SCALE: 3t4' = V-D' SECTION G-G (INTERNALS) SCALE: 3W = V-O' LOW ROW OPENING TO CARTRIDGE CHAMBER DO NOT USE THIS SO KNOCKOUT HOLD DOWN DESIGN NOTES: BAR 1. DESIGN LOADINGS: 1K 19' PwkFlb1® A HS-20 TRUCK WHEEL LOAD WI IMPACT. CARTRIDGE STACK B. SOIL DENSITY: 120 PCF(AWNED). C. WATER TABLE: TOP OF STRUCTURE (ASSUMED). D. DRY LATERAL EARTH PRESSURE (EFP) : 40 PCF. E. LATERAL LIVE LOAD SURCHARGE: 80 PCF. 2 CONCRETE: A 28 DAY COMPRESSIVE STRENGTH: fc = 5,000 PSI. 3. REINFORCING: A. REBAR: ASTM A-615 OR A-706 GRADE 60. B. MESH: ASTMA-1064 GRADE 65. 4. CEMENT: ASTM C-150. 5. DESIGN SPECIFICATIONS & CODES: A ASTM C-858, ASTM C-913. B. ACI-316 BUILDING CODE. 6. PRECAST DESIGN DOES NOT INCLUDE ANY LATERAL OR SURCHARGE LOADS FROM OTHER BUILDING OR FOUNDATIONS ADJACENT TO THIS STRUCTURE. THIS STRUCTURE SHALL BE KEPT A MINIMUM OF 1:1 RATIO AWAY FROM OTHER FOOTINGS OR FOUNDATIONS. CONTRACTOR NOTES: 1. OLDCASTLE TO PROVIDE & INSTALL ALL INTERNAL COMPONENTS(SOME COMPONENTS NOT SHOWN). 2. CONTRACTOR TO PROVIDE CRANE AND RIGGING CAPABLE OFF LIFTING WEIGHTS SHOWN. 3. FRAMES MAY BE ADJUSTED TO GRADE Wl NON -SHRINK GROUT. Treatment Flow Rate 10.2 gpm / 0.023 cfs Total Flow Capacity 1.3 cfs Stormwater Figure 11-4.1.7b Concrete Washout Area Strew bale 10 mi plastic lining SntwiB Native material (2 per Deb) (Optional) Wood or meta stares (2 par bast) Section B-B f�-- 3m Minimum Stake Bt Varies Straw bale J (tYP ) Plan Binding wire Plywood 1200 mm x 610 mm Wood post painted white (89 mm x 89 mm Lag screws x2.4 m) (12.5 mm) c: i Black letters i1oncR wnsNouTtl 150 mm height 915 mm 11 91155 mm Concrete Washout Sign Detail (or equivalent) �B �-- 10 trill pleeflo lining 50 mm 200 mm 3.05 mm dia. steel wine Staple Detail Notes: 1. Actual layout determined in the laid. 2. The concrete wasbo t sign shall be Installed within 10 m of the temporary concrate washout facility. T "Above Grade" with Straw Bales Figure 11-4.1.7b Concrete Washout Area NOT TO SCALE DEPARTMENT OF Revised June 2015 ECOLOGY Please we h*:IAvww.eoy.wa.gdv/copyrA ftW for copyright notice including permissions, State of Washington lhrHt tan of Habiliy, and disdeimer. 2014 Stormwater Management Manual for Western Washington Volume 11- Chapter 4 - Page 323 Figure 11-4.1.1 Stabilized Construction Entrance d �XTsa�Roa Insw driveway aivert If Mere is a roadside ditch present Notes: 1. Driveway shall meet the requirements of the permitting agency. 2. N is recommended that the entrance be dawned So that runoff drains off the pad. 4' - 8' quarry spells GeotexNle 12' minimum thickness 100' min NOT TO SCALE Figure II-4.1.1 Stabilized Construction Entrance DEPARTMENT OF Revised June 2015 ECOLOGY Please see hdp pwww acy m goHcop),dghthhnl for copyright notice including permissions, State of WaShinglonj fsilalion of liability, and disclaimer. 2014 Stomlwater Management Manual for Westem Washington Volume 11- Chapter 4 - Page 273 Figure 11-4.2.12 Silt Fence Joints in filer fabric shall be spliced at posts. Use staples, Wine rings or equivalent to attach fabric to posts 2')0 by 14 Ga. wire or equivalent, If standard strength fabric used --� rr--------_.....,-------- rl MlNmlxmh I g iTim I I Tom- �7I 4'x4•tranch I I I I Poet apeckg may be Increased 108' d wire bacldng is used Yxr wood posts. steel farce posts, or equivalent 2YY by 14 Ga. Wire or equivalent, if standard strength fabric used Filter fabric Seddia bench with nellve sod or- 1.5• waded gravel I 2'min lArdmurn 4'x4•trench J/LJ 2-YZ wood posts, steel fence posts, or equivalent NOT TO SCALE Figure II-4.2.12 Silt Fence DEPARTMENT OF Ravised October 2014 ECOLOGY Please see hNpy/www.ecy.wa.gov/copyrlghthrml for copyright notice Including permissions, State of Washington Bnnitation of liability, and disclaimer. 2014 Stormwater Management Manual for Western Washington Volume ll - Chapter 4 - Page 369 k►�J PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anocortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of coon fiance with applicable laws and permit requirements. 0114.15 CITY ENGINEER DATE The acceptance will expire one year from the date noted above. Rev, B October 16, 2019 V � O cc qw a C\2 � � r _ .--I E� x �1 w � I� O a rn y� rn a> � Cd cc oa to �N F2 R s.: O `d ^� SHEET NO. C5 REV.: - JOB NO: 2018-11 DATE: July 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRIGSTAD SHEET 5 OF G LANDING GRADE BREAK SEE CONTRACT PLANS - 4' - O" MIN. CEMENT CONCRETE SIDEWALK- SEE NOTE 5 2.0% MAX. FLARE (TYP.) NOTES CURB RAMP WIDTH 4'- O" MIN. LANDING TO MATCH q CURB RAMP WIDTH -SEE CONTRACT PLANS CURB RAMP WIDTH 4'- W MIN. 1. Provide a separate Curb Ramp for each marked or unmarked crosswall LANDING TO MATCH CURB RAMP WIDTH - SEE CONTRACT PLANS Curb Ram location shall be laced within the width Of the associated P P GRADE BREAK LANDING crosswalk or as shown in the Contract Plans. SEE CONTRACT PLANS - CURB RAMP 4' - O" MIN. GRADE BREAK 2• Where "GRADE BREAK" Is called Out, the entire length of the grade CEMENT CONCRETE SIDEWALK - break between the two adjacent surface planes shall be flush. SEE NOTE 5 PROVIDE SMOOTH TRANSITION TO SIDEWALK 2--0- 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurtt SEE CONTRACT PLANS - WIDTH (TYP.) MIN. SEE CONTRACT PLANS - nances In front Of the Curb Ramp or on any part Of the Curb Ramp Or 4' - O" MIN. 2.0� MAX. 4' - 0' MIN. Landing. 3/8" EXPANSION JOINT (TYP.) -SEE �. BUFFER WIDTH -MATCH TO CURB RAMP DEPTH (TYP ) See the Contract Plans for the curb design specified. See Standard PI, 3/8' EXPANSION CURB RAMP STANDARD PLAN F-30.10 v 4. g P JOINT (TYP.) - SEE v �,, F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and TANDARD PLAN F-30.10 GRADE P J � BREAK TRANSITION TO SIDEWALK BUFFER, IF� Pedestrian Curb details. GRADE BREAK PRESENT, OR TO BACK OF CURB (TYP.) - �� ,o ° SEE CONTRACT PLANS 5 See Standard Plan F-30.10 for Cement Concrete Sidewalk details. CURB, OR CURB AND GUTTER - SEE NOTE 4 FACE OF CURB MEASURED PARALLEL TO CURB (TYP.) SLOPE TREATMENT - SEE STANDARD PLAN F-30.10 .0%MAX. EiEiiEEEi ii•.^ir.i 10.0%MAX- See Contract Plans for width and placement of sidewalk. ......... ..::: •:: :..:.:.. CURB, OR CURB CEMENT CONCRETE - AND GUTTER - PEDESTRIAN CURB - 6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include DETECTABLE WARNING SURFACE - SEE NOTE 4 D SEE NOTE 4 the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, SEE STANDARD PLAN F45.10 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F-45.10 Pedestrian Curb, Or Sidewalk. FACE OF CURB DEPRESSED CURB AND GUTTER - CROSSWALK SEE NOTE L PLAN VIEW TYPE PERPENDICULAR A DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F45.10 4'- 0" MIN. 1 ' - "MAX. SEE CONTRACT PLANS SEE NOTE 7 2.0% MAX. GRADE BREAK 8.3% MAX, LANDING J CURB RAMP J a SECTION OA ALL SIDEWALK RAMPS TO BE STAMPED PER ST-06 OF THE COA EDS STANDARDS, THE DWD ARE EITHER BLACK AND WHITE OR COLOR, DEPRESSED CURB AND GUTTER 7• The Curb Ramp maximum running slope shall not require the ramp lenl CROSSWALK to exceed 15-feet to avoid chasing the slope indefinitely when connectil to steep grades. When applying the 15-foot maximum length, the runnil slope of the Curb Ramp shall as flat as feasible. $• Curb Ramp, Landing, and Flares shall receive broom finish. See PLAN VIEW LEGEND Standard Specifications 8 14. TYPE PERPENDICULAR B EIN EITHER DIRECTION (SHOWN WITH BUFFER) CEMENT CONCRETE DETECTABLE WARNING SURFACE - PEDESTRIAN CURB - SEE STANDARD PLAN F45.10 GRADE BREAK SEE NOTE 4 COUNTER SLOPE - 5.0% MAX. 3' R TYP DEPRESSED CURB AND GUTTER - SEE NOTE 4 TOP OF ROADWAY CEMENT CONCRETE CURB D, AND GU ER -SEE NOTE 4 DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F-10.12 CURB RADIUS DETAIL O CEMENT CONCRETE CURB RAMP "TYPE 'MIT - SEE NOTE 6 A\ ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT PERPENDICULAR CURB RAMP STANDARD PLAN F-40.15-02 6120113 ALL TRAFFIC CURBS TO BE CONSTRUCTED TO WSDOT STNDARD PLAN F-10,12-03 "CEMENT CONCRETE TRAFFIC CURB AND GUTTER", 2 Z BROOMED VARIES 3/8" (IN) EXPANSION JOINT (TYP.) - FINISH (TYP.) (SEE CONTRACT PLANS) SEE STANDARD PLAN F-30.10 2.0°/D MAX. MATCH SIDEWALK WIDTH CONCRETE CEMENT 0. \\\\\��\�. � (SEE CONTRACT) SIDEWALK . MATCH SIDEWALK WIDTH (SEE CONTRACT) 6' - 0" VARIES 6'- 0' (SEE CONTRACT) 3/8" (IN) EXPANSION JOINT (TYP.) - - "'r SEE STANDARD PLAN F30.10 F- L)\\�\\ \ \ FINISH (TYP.) Z .r Z O J" LU W \ Wr LU \ (SEE NOTE 1) 2' -6- 2' - 6" CEMENT CONCRETE DRIVEWAY ENTRANCE (SEE NOTE 1) CEMENT CONCRETE BUFFER STRIP (TYP.) E (TYP) (TYP) CURB & GUTTER SIDE SLOPE (TYP.) F CURB & GUTTER (SEE NOTE 3) (SEE NOTE 3) PLAN VIEW DRIVEWAY ENTRANCE PLAN VIEW TYPE 3 SIDE SLOPE (TYP.) TYPE 4 SEE RAISED EDGE DETAIL - THIS SHEET 1`I ALL CUT MIN. SLOPES 2.Oq 1J Oa - / SIDEWALK (SEE CONTRACT) 112 (IN) R. (TYP.) e 2 0% MAX. 3/8" (IN) PREMOLDED JOINT FILLER WITH RAISED EDGE SIDEWALK (SEE CONTRACT) 1/2' (IN) R. (TYP.) 1 2.0% MAX. a 3/V (IN) PREMOLDED JOINT FILLER ADJACENT TO CURB (STEEP FILL SLOPES) SIDEWALK (SEE CONTRACT) - 112- (IN) R. (TYP.) `v 2.0% MAX 3/8' (IN) PREMOLDED JOINT FILLER ADJACENT TO CURB FOR SIDE TREATMENT SIDEWALK 6 1/2" 8(ii) 6 112" SEE OTHER SIDEWALK SECTIONS (SEE CONTRACT) CONTRACTION FACE OF CURB JOINT 51/2" 1" CURB NOT INCLUDED IN BID ITEM - SEE STANDARD PLAN F-10.12 1 2.0% MAX 'v D OFINISHED GRADE 1" (IN) BELOW TOP OF CONCRETE SURFACE CURB NOT INCLUDED IN BID ITEM - SEE STANDARD PLAN F-10.12 WALL OR BARRIER 1/2"(11J1 R. CURB NOT INCLUDED IN BID ITEM - SEE STANDARD PLAN F-10.12 D D io ROADWAY 1' (IN) R. D SEE CURB FACE DETAIL D MONOLITHIC CEMENT CONCRETE D CURB AND SIDEWALK 6^ s 1/z^ t^ O NOTE I - CURB FACE DETAIL 1. Four feet of the sidewalk width shall be the minimum pedestrian accessible W route free of vertical and horizontal obstructions. Gratings, Access Covers, EXTEND SIDEWALK TRANSVERSE EXPANSION Junction Boxes, Cable Vaults, Pull Boxes and other appurtenances within the JOINTS TO INCLUDE CURB (FULL DEPTH) sidewalk must have slip resistant surfaces, be flush with surface, and match d' grade of the sidewalk. O 3/8" (IN) PREMOLDED JOINT FILLER SIDEWALK ADJACENT TO WALL DETAIL DGE OR PEDESTRIAN RAILING BARRIER - SEE _ -\` _ SIDEWALK CONTRACT PLANS (SEE CONTRACT) - 1/2" (IN) R. (TYP.) CURB NOT INCLUDED IN BID ITEM - FLUSH -i `v 2.0% MAX. SEE STANDARD PLAN F-10.12 VERTICAL WALL - _/� 3/8" (IN) PREMOLDED SEE DETAIL JOINT FILLER (TYP.) ADJACENT TO CURB AND RAILING OR WALL T-O" MIN. SIDE TREATMENT SIDEWALK BUFFER STRIP OTHER SIDEWALK (SEE CONTRACT) (SEE CONTRACT) SECTIONS 1 1/2" (IN) R. CURB NOT INCLUDED IN BID ITEM - a 2.0% MAX. (TYP.) SEE STANDARD PLAN F-10.12 FINISHED GRADE V (IN) BELOW TOP OF CONCRETE SURFACE FOR PLANTING - FLUSH IF PAVED ADJACENT TO BUFFER STRIP 1/2" (IN) R. (TYP.) MATCH SIDEWALK WIDTH (SEE CONTRACT) (SEE CONTRACT) DRIVEWAY ,Il-� I 1/2" (IN) LIP BETWEEN (SEE NOTE 7) IL 2.0% MAX `O.( ROADWAY GUTTER & CURB (OR SEE CONTRACT) SIDEWALK DRIVEWAY DEPRESSED 3/8" (IN) EXPANSION JOINT (TYP.) - RAMP CURB &GUTTER SEE STANDARD PLAN F-30.10 (SEE NOTE 3) SECTION O "CEMENT CONCRETE DRIVEWAY ENTRANCE TYPE 3" PAY LIMIT DRIVEWAY (SEE NOTE 7)� CL. 4000 CONCRETE PER STANDARD SPEC. 8.06.3 ISOMETRIC VIEW TYPE 3 'CEMENT CONCRETE DRIVEWAY ENTRANCE TYPE 4" PAY LIMIT DRIVEWAY (SEE NOTE 7) CL. 4000 CONCRETE PER STANDARD SPEC. Ill THIS ENTRANCE TYPE SHALL NOT BE USED ALONG A PEDESTRIAN ROUTE 1/2" (IN) R. (TYP.) DRIVEWAY J (SEE NOTE 7) DRIVEWAY RAMP SECTION O 1/2" (IN) LIP BETWEEN ROADWAY GUTTER & CURB (OR SEE CONTRACT) DEPRESSED CURB & GUTTER (SEE NOTE 3) WSDOT STND PLAN F-80.10-03 ISOMETRIC VIEW CEMENT CONCRETE TYPE DRIVEWAY ENTRANCE TYPES 3, & 4 SHEET 2 OF 2 SHEETS 6111114 DRAINAGE GRATE GRATE FRAME IR! SEDIMENT AND DEBRIS DRAINAGE GRATE - RECTANGULAR GRATE SHOWN U11 BELOW INLET GRATE DEVICE FILTERED WATER NOT TO SCALE TRIM will service. a d collected material. OVERFLOW BYPASS BELOW INLET GRATE DEVICE " cc GI I qw a 0" C BROOMED FINISH (TYP.) 0" A E 4" (IN) WIDE, SMOOTH -TROWELED t2 PERIMETER [ Q CO �+ CEMENT CONCRETE CURB �( rZ4* d' 4 G (CURB AND GUTTER SHOWN) C:I, O " NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12 CQ 4 E� � 03 OWN O E � i \ W E-•� � CONTRACTION JOINT IN SIDEWALK ONLY W O LEVEL 1/L" FF F�q EXPANSION JOINT IN BOTH 1/2" (IN) R. 2a�� CURB AND SIDEWALK A `v D m ISOMETRIC VIEW D ' RAISED EDGE DETAIL EXTEND SIDEWALK TRANSVERSE JOINTS TO INCLUDE RAISED EDGE f op p p. PREMOLDED JOINT FILLER EO EXPANSION JOINT 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it 2, The BIGD shall have a built-in high -flow relief system (overflow bypass). 3. The retrieval system must allow removal of the BIGD without spilling the 4. Perform maintenance in accordance with Standard Specification 8-01.3(15). RETRIEVAL SYSTEM (TYP.) STORM DRAIN INLET OVERFLOW BYPASS (TYP.) PROTECTION STANDARD PLAN 1-40.20-00 C�J JOINT AND FINISH DETAIL 1/8'TO1/4" CEMENT CONCRETE SIDEWALK STANDARD PLAN F-30.10-03 "p p SHEET 1 OF 1 SHEET 6111114 (Z)CONTRACTION JOINT PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anocortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of complIkInce with applicable laws and permit requirements. �- 11.1q,1� CITY ENGINEER DATE The acceptance will expire one year from the date noted above. 16-2019 Rev, B, October 16, 2019 U a a N D 4-) C-4 F, Zj C\2 CQ °'ate N moo+ V 1 �It Fi •--1 r� SHEET NO. C6 REV.: - JOB NO: 2018-11 DATE: July 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRRIGSTAD SHEET 6 OFJ 0 0 e. i e SEWER C SEWER ; • • e• y'e a ' • e e • •e n • G�� F�O� •e •e o OUTSIDE PAVED AREAS 0 PAVED AREAS J. D B rU n < 3 2' d. _ LEGEND: b A. MANHOLE RING AND COVER PROFILE B. EXISTING SURFACE C. 3000 P.S.I. CEMENT CONCRETE PERIMETER SEAL D. INSTALL PRECAST ADJUSTMENT RINGS OR CONCRETE BLOCKS AS NECESSARY TO MATCH FINAL GRADE. NOTES: 1. THE CONCRETE SHALL CONFORMING TO THE CURRENT WSDOT 9-03.1(4) AND BE 5.5 SACK MIX. (MINIMUM 3000-PSI 28-DAY STRENGTH. 2. WHERE DEPTH OF NECK EXCEEDS 24 INCHES, ADJUST MANHOLE TO GRADE BY INSERTING A NEW MANHOLE BARREL SECTION BETWEEN THE CONE AND EXISTING BARREL. 3. ADJUSTMENT RINGS/BLOCK SHALL BE SET IN 3/4" NON -SHRINK GROUT, PLASTER SMOOTH INSIDE AND OUT. 4. STEPS OR RUNGS SHALL BE ADDED AS NEEDED. 5. PRECAST ADJUSTMENT RINGS SHALL BE CAST WITH GROOVE TO ALLOW FIELD INSTALLATION OF SAFETY STEP. 6. MORTAR SHALL BE PLACED BETWEEN EACH LEVEL OF ADJUSTMENT CONCRETE BLOCKS, ADJUSTMENT RINGS, TOP OF CONE SECTION AND BOTTOM OF IRON RING. 7. THE CONCRETE PERIMETER SEAL SHALL EXTEND TO 12 INCH MINIMUM OR 2 INCHES BELOW THE BOTTOM OF THE ADJUSTMENT RINGS OR BLOCKS. S. THE UnLffV SHOWN IS A SANFFARV SEWER MANHOLE LI IL1TY CASINGS LIKE WATER VALVES, MONUMENTS, GAS VALVES, ETC. WILL FOLLOW THE SAME PROCEDURE AND GUIDELINES. SCALE: NOT TO SCALE �%IV 0" DETAIL: ST-02 DRAWN BY: S.L. FILE: ST-02 STRUCTURE ADJUSTMENT.DWG STRUCTURE ADJUSTMENT EFFECTIVE DATE: REVIEW BY DATE: REVIEWER: . AND PERIMETER SEAL ,01-20-2005 05-31-2013 BUCKENMEYER �'a 0 `4� PPENDIX A - STANDARD DRAWING 2009 SIGN POST - 2 1/4" (IN) SQUARE, 12-GAGE STEELTUBE o SIGN POST - 2" (IN) o OR 2 1/4" (IN) SQUARE, N F 12-GAGE STEEL TUBE z 0r. Z g W ,N. III W TOP OF LOWER G � z SQUARE TUBE FINISHED H °- w FINISHED GROUND LINE��! J w : 0) E m GROUND .r LINE SIGN POST - 2" (IN), 2 1/4" (IN), OR 2 1/2^ (IN) a SQUARE, 12-GAGE W STEELTUBE 0 Z w W FINISHED GROUND LINE PUBLIC EASEMENTS 0 O PAVED STREET SCALE: NOT TO SCALE DRAWN BY: S.L. FILE: ST-01 UTILITY TRENCH TYPICAL.DWG EFFECTIVE DATE: REVIEW BY DATE: REVIEWER: 01-20-2005 05-31-2013 BUCKENMEYI x N W In x 5 N O IL a O N = W W ti SIGN PANEL SIGN BRACE, WHEN REQUIRED - SEE STD. PLAN G-50.10 N � SIGN POST - 2 112' (IN) 2 SQUARE, 12-GAGE STEEL TUBE (SEE w NOTE 3) FCI I W STABILIZER FIN — Q m io II CLEAN -OUT BAR ~ BOLT STOP FOR SIGN POST ANCHOR w 0 LEG ANGLE LOWER SIGN POST SUPPORT - 2 1l2" (IN) COMPACTED NATIVE BACKFILL MATERIAL SQUARE, 12-GAGE STEEL TUBE COMPACTED NATIVE ELEVATION 9°°-jl DIAM. 12" DIAM. BACKFILL MATERIAL TYPE ST-3 SIGN SUPPORT ELEVATION ELEVATION BURIED POST SIZE DEPTH TYPE ST-1 SIGN SUPPORT TYPE ST-2 SIGN SUPPORT z-s^ 2^,21/4^ 3'- 0" 2 1 /2" TOP OF SIGN TOP OF �� SIGN POST SIGN PANEL C w BOTTOM OF SIGN 11,\r- VIEW OA SIGN POST TYPE ST-1 SIGN POST SIGN POST LOWER SIGN POST SUPPORT SIGN POST WEDGE STABILIZER FIN HEX BOLT WITH NUT AND WASHER (TYP.) ANCHOR LEG ANGLE BOLT STOP FOR SIGN POST TYPE ST-2 BOTTOM OF SIGN FINISHED GROUND LINE ' 1B —III _ -- - - - _- ll_ —III _ _ -_ __ 'I 1 II II I I -- - - __ I 0 ITI—--_- - - - -- -- III. ------ - - - - -- r-0' MINIMUM 1A CONCRETE\ PAVED STREET GENERAL NOTES: IA. 3 INCH MINIMUM CLASS B ASPHALT, PER SECTION 2-06,3(2) OF THE 2002 WSDOT STANDARD SPECIFICATIONS FOR ROADS, BRIDGES AND MUNICIPAL CONSTRUCTION. 1B. CONCRETE PATCH TO BE THE SAME DEPTH AS EXISTIN( CONCRETE STREET. SB 1C. 12 INCHES - COMPACTED DEPTH TOP SOIL TO BE FINISHED WITH SEED OR SOD. SEED TO BE WEED FREE. 2, SAWCUT 3. ALL JOINTS BETWEEN OLD AND NEW ASPHALT TO BE SEALED (SECTION 5-05.3(8)B) USING A HOT POURED JOINT SEALANT, PER SECTION 9-04.20). 4. 6 INCHES - CRUSHED SURFACING, PER SECTION 9-03.(9)3, AND PREPARED PER SECTION 2-06.3(2), 'SUBGRADE FOR SURFACING'. 5(A). GRAVEL BASE MATERIAL, APPROVED WSDOT SPECIFIEI MATERIAL, OR SPECIFIED IN THE APPROVED PLANS, MATERIAL TO BE COMPACTED TO 95%, PER SECTION 7-09.3(11) 'COMPACTION BACKFILL'. SEE ALSO, SECTION 7-08.3(3) 'BACKFILLING'. 50). CONTROL DENSITY FILL WILL BE REQUIRED BY THE CONTRACTOR IF THE TRENCH CROSSING FAILS. 6, THE PIPE ZONE SHALL BE BACKFILLED WITH SAND BACKFILL TO 12-INCHES ABOVE THE PIPE, PER SECTION 7-09.300) 'BACKFILLING TRENCHES'. THE PIPE ZONE SHALL BE COMPACTED TO 907, PER SECTION 7-08.3(1)C, 7. SAND BACKFILL - PIPE ZONE B. 6 INCHES - SAND BACKFILL 9, LAY ALUMINUM LOCATE TAPE A MINIMUM OF 12 INCHES BELOW FINISHED GRADE AND 12 INCHES ABOVE PIPE. DETAIL: ST-01 STREET CUT REPAIR TYPICAL PPENDIX A - STANDARD DRAWING 2009 i x (� N w F x J~Z O W a TOP OF i LOWER SQUARE TUBE ll � 1N ` w � 1K NYLON WASHER o �T io " �B1OLT STOP 7/16" (IN) INSIDE DIAMETER (I.D.) FOR SIGN POST STEEL FLAT WASHER 3/8" (IN) DIAM. LOWER SIGN POST 3 1/2" (IN) LONG SUPPORT - 3" (IN), HEX HEAD BOLT 7-GAGE, HOT -DIP GALV., HEAVY-DUTY ANCHOR SIGN PANEL 12COMMERCIAL CONCRETE DIAM. ELEVATION E ST-4 SIGN SUPPORT SIGN POST ,61 LOWER SIGN _/� F LA NGED SHOULDER BOLT POST SUPPORT WITH NUT AND WASHERS - 2 REQUIRED (TYP.) CLEAN OUT BAR BOLT STOP FOR SIGN POST —3 TYPE ST-4 DETAIL OB 2 v �a V 6 I i v r�11' v n kF 4 F O - F v O 5 9 v. v v � e DETAIL NOTES: 1, 8 INCH OFFSET FROM CENTER LINE ON SEWER LINES ENTERING THE MANHOLE BASE AT LESS THAN 80 DEGREE . 2, LESS THAN 80 DEGREES TYPICAL. 3, 80' OR MORE TYPICAL, 4. CONCRETE SHELF SHALL HAVE A BROOM FINISH 5. FLOW CHANNELS MUST BE FINISHED SMOOTH 6. PRECAST BASE TYPICAL 7, PVC TO CONCRETE ADAPTOR COLLAR 8. COLLAR SHALL EXTEND INTO THE MAN HOLE NO MORE THAN 3/4 OF AN INCH. 9. ALL COLLARS AND LIFTING HOLES SHALL BE GROUTED INSIDE AND ❑UTSIDE THE MAN HOLES TO STOP INFILTR TION. SCALE: NOT TO SCALE DRAWN BY: S.L. FILE: S-01 FLOW CHANNEL MANHOLE.DWG EFFECTIVE DATE: REVIEW BY DATE: REVIEWER: 07-20-20C 05-31-2013 BUCKENMEYI 3/8" (IN) HEX HEAD NUT 7/16" (IN) I.D. STEEL LOCK WASHER SIGN POST STEEL SIGN SUPPORT TYPES ST-1 - ST-4 INSTALLATION DETAILS WSDOT STANDARD PLAN G-24.50-05 SHEET 1 OF 1 SHEET 08/7/19 DETAIL: S-01 FLOW CHANNEL TYPICAL PENDIX A - STANDARD DRAWING 2009 ADDITIONAL STANDARD DETIALS COA STANDARD WATER DETAIL PW#19-136-DEV This plan sheet is accepted for construction in accordance with the City of Anacortes ordinances and policies. Actual conformance of the design with applicable laws is the sole responsibility of the professional engineer, whose name and stamp appear on this sheet. Acquiring, complying with, and providing mitigation for all Federal, State, County, and Local Laws, permits, and mandates, including but not limited to the Endangered Species Act, Federal Wetland Permit, State Department of Fisheries Hydraulics Permit, Federal Flood Plain Permits, National Pollutant Discharge Elimination System Permits is the responsibility of the Developer, Landowner, and their Engineer. The issuance of this permit shall not be construed as proof of com li is with applicable laws and permit requi ments. �� 11.t5.L- CITY ENGINEER DATE The acceptance will expire one year from the date noted above. D-16-2019 Rev, B, October 16, 2019 O cc q a � zo v Q� C\2 �I wE� Pq O Z U f/] a W a> a a� Z 4 CO fr -N Cn C\2 M � Co . CO O 4•-> or M ^T� �N! r4-) f-i r� �I SHEET NO. C'7 REV.: - JOB NO: 201E-11 DATE: Oct. 2019 SCALE: Noted DRAWN: D. HERRIGSTAD CHECK: D. HERRRIIGSTAD SHEET! ! OF