GENERAL NOTES:
1. WORK HOURS:
THE CITY OF ANACORTES ORDINANCE ALLOWS WORK FROM 7:00 AM TO 10:00 PM, SEVEN
DAYS A WEEK (COA ORD. #2316). SOMEONE IN CHARGE SHALL BE ON -SITE AT ALL TIMES
WHEN WORK IS IN PROGRESS. IF WORK IS DONE ON WEEKENDS, PLEASE INFORM THE
PROJECT MANAGER SO THE CITY OF ANACORTES CAN HAVE AN INSPECTOR ON -SITE.
CONTRACTOR WILL BE BILLED FOR CITY OF ANACORTES OVERTIME.
2. CALL
48-HOURS
BEFORE THE FOLLOWING:
FOR
INSPECTION CONTACT 360.299.1951.
A.
PRIOR
TO
WORK START UP.
B.
PRIOR
TO
ANY UTILITY CONSTRUCTION IN THE RIGHT-OF-WAY.
C.
PRIOR
TO
POURING CAST -IN -PLACE CONCRETE STRUCTURES.
D.
PRIOR
TO
PLACING ANY CRUSHED ROCK ON ROADWAY SUBGRADE.
E.
PRIOR
TO
PLACING CURB, GUTTERS AND SIDEWALKS.
F.
PRIOR
TO
ASPHALT PAVING.
3. MATERIALS AND WORKMANSHIP:
A. ALL MATERIALS USED, MUST MEET WSDOT, APWA AND CITY OF ANACORTES SPECIFICATIONS
B. ALL WORK AND MATERIALS THAT DO NOT MEET THE ABOVE SPECIFICATIONS, MUST BE
REMOVED AS DIRECTED BY THE PROJECT INSPECTOR.
C. SUBGRADE COMPACTION TESTS: WILL BE DONE BEFORE AN C.S.B.C. IS PUT IN PLACE,
ALL TRENCHES WILL BE TESTED FOR COMPACTION. THE MATERIAL TESTING LAB NEEDS
24-HOUR NOTICE. USE THE TESTING PROTOCAL PROVIDED BY THE CITY. ITEMS TO BE
COMPACTION TESTED WILL INCLUDE THE PIPE BEDDING (SECTION 7-08.3(1)C), BACKFILL
SECTION 7-08.3(3) AND SUB -GRADE FOR SURFACING (SECTION 2-06.3(2) AND ASPHALT
SECTION 5-04.3(10)B).
D. INSPECTIONS: ALL ASPECTS OF THIS PROJECT WILL BE INSPECTED INCLUDING PIPING,
BACKFILL, SUB -GRADE, CONCRETE AND ASPHALT, AS WELL AS FORMS, CURB, GUTTER AND
SIDEWALK. IF A PORTION GETS BACKFILLED BEFORE INSPECTION, THE CONTRACTOR WILL
DIG UP THAT PORTION FOR INSPECTION. 24-HOUR NOTICE REQUIRED. KNOW THE SCHEDULE
AND LET THE CITY KNOW.
E. TESTING PROTOCAL: PRIOR TO CONSTRUCTION, A PROCTOR AND SIEVE ANALYSIS SHALL
BE SUBMITTED, REVIEWED AND APPROVED BY THE CITY OF ANACORTES ON ALL MATERIAL
USED IN THE RIGHT-OF-WAY. SEE THE CITY OF ANACORTES TESTING SCHEDULE.
F. ALL COMPACTION TEST SHALL BE APPROVED BY THE CITY OF ANACORTES ENGINEER AND
PROJECT MANAGER PRIOR TO PLACING OF CRUSHED SURFACING, ASPHALT, CURB, GUTTER
AND SIDEWALK (INCLUDING TRENCH RESTORATION WHEN TEST MAY BE REQUIRED IN EACH
LIFT).
G. CITY OF ANACORTES MAY REQUIRE ADDITIONAL TESTS ON SUBGRADE, TRENCHES, CONCRETE,
OR ASPHALT. THE COST OF TESTING SHALL BE PAID FOR AS INDICATED IN THE CONTRACT
DOCUMENTS.
4. TRAFFIC CONTROL AND PUBLIC SAFETY:
A. FLAGGING: ALL FLAGGERS MUST HAVE FLAGGING CERTIFICATES AND MUST HAVE ATTENDED
A FLAGGING COURSE OR AN OFF -DUTY POLICE OFFICER IS REQUIRED. THE JOB WILL BE
SHUT DOWN IF ANY UNCERTIFIED PEOPLE ARE FLAGGING. A STOP WORK ORDER WILL BE
GIVEN AND WORK WILL NOT PROCEED UNTIL A CERTIFIED PERSON IS FLAGGING.
B. SIGNAGE: ALL SIGNAGE MUST BE PER THE MANUAL UNIFORM TRAFFIC DEVICES. BEFORE
THE JOB IS TO BEGIN, PROPER SIGNAGE WILL BE IN PLACE WITH FLAGGERS IN PLACE IF
NEEDED. EXTRA SIGNAGE MAY BE NEEDED. BE READY TO RENT SIGNS IF NEEDED.
C. TRAFFIC CONTROL PLAN: NEEDS TO BE SUBMITTED AND APPROVED BY THE PUBLIC WORKS
DIRECTOR PRIOR TO CONSTRUCTION START. TRAFFIC CONTROL PLAN SHALL INCLUDE THE
LOCATION OF SIGNAGE, FLAGGERS, WORK ZONE, SAFE ZONE, AND TRAFFIC FLOW AND NEEDED
DIMENSIONS. NO DETOURS ALLOWED WITH APPROVAL FROM THE PUBLIC WORKS DIRECTOR.
D. FOR STREET CLOSURE: CALL 911 OR FOR CELL PHONES, CALL 360.336.3131.
E. CONSTRUCTION SAFETY: IS THE RESPONSIBLITY OF THE CONTRACTOR.
5. ROADWAY EMBANKMENT AND SUBGRADE CONSTRUCTION:
A. CRUSHED SURFACING SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY. NO
RECYCLED MATERIAL ALLOWED.
B. EMBANKMENT AND SUBGRADE MUST BE COMPACTED TO 95% OF MAXIMUM DENSITY.
C. PROPER MOISTURE MUST BE MAINTAINED THROUGHOUT PLACING AND COMPACTING.
D. COMPACTION TESTING TO BE PERFORMED BY AN INDEPENDENT LAB. USE A "MODIFIED
PROCTOR".
6. TRENCHES IN DEVELOPED RIGHT-OF-WAY:
SEE CITY OF ANACORTES STANDARD CONSTRUCTION DETAILS AND SECTION 7 OF THE
CURRENT WSDOT SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION.
A. PIPE ZONE SHALL BE COMPACTED TO 90% OF MAXIMUM DENSITY.
B. TRENCH ZONE SHALL BE COMPACTED TO 95% FO MAXIMUM DENSITY IN 12-INCH LIFTS.
C. CRUSHED SURFACING SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY. NO RECYCLED
MATERIAL ALLOWED.
7.
A. ANY PERMANENT FLOW CONTROL FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE
MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE
STORAGE CAPACITY. IF THE FACILITY IS TO FUNCTION AS AN INFILTRATION SYSTEM, THE
TEMPORARY FACILITY MUST BE GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST
THREE (3) FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY.
B. OVERFLOWS, SPILLWAYS, GRAVEL FILTER WINDOWS, MUST BE CONSTRUCTED PER PLANS AND
SPECIFICATIONS. NO DEVIATIONS. AS -BUILT FOR VERIFICATION REQUIRED.
C. QUARRY ROCK MUST BE SOUND "HARD" DURABLE ROCK. NO RECYCLED MATERIAL.
D. GRASS LINED SWALES SHALL BE CONSTRUCTED PER THE DETAILS PROVIDED. NO DEVIATION
ALLOWED. ALL SWALES MUST BE OPERATIONAL BEFORE ACCEPTANCE.
E. CATCH BASINS MUST BE SET TO LINE GRADE USING NO MORE THAN TWO (2) ADJUSTMENT
BRICKS.
F. MINIMUM 1-FOOT SEPARATION BETWEEN PIPES IN TYPE II CATCH BASINS.
8. RESTORATION OF RIGHT-OF-WAY:
A. CONTRACTOR MUST LEAVE THE RIGHT-OF-WAY, EQUAL TO EXISTING OR BETTER CONDITION.
B. PLACE COMPACTED TOPSOIL (SECTION 9-14.1(1), (2) AND (3)) AND SEED ALL AREAS
DISTURBED BY EXCAVATION. (SECTION 9-14.2)
C. ALL DRAINAGE SYSTEMS MUST BE FULLY CLEANED, RESTORED AND OPERATIONAL BEFORE FINAL
ACCEPTANCE. (SECTION 7-07.3)
9. FINAL INSPECTION AND ACCEPTANCE:
SEE SECTION 1-05.1 1 AND SECTION 1-08.5
A. WHEN THE CONTRACTOR HAS COMPLETED ALL OF THE WORK ON THE APPROVED PLANS, THE
CONTRACTOR WILL:
- COMPLETE THE "FINAL INSPECTION GUIDELINES FOR CONTRACTORS INSPECTION FORM".
- GIVE THE COMPLETED "FINAL INSPECTION GUIDELINES FOR CONTRACTORS INSPECTION FORM"
TO THE PUBLIC WORKS INSPECTOR AND REQUEST A SITE INSPECTION. ALL SITE INSPECTIONS
ARE ON WEDNESDAY BETWEEN 9 AM TO 12 PM.
B. THE PROJECT MANAGER, ENGINEER OF RECORD, INSPECTOR, CONTRACTOR AND OTHER CITY
OF ANACORTES DEPARTMENTS WILL WALK THE SITE AND CREATE A PUNCH LIST. THE CONTRACTOR
WILL COMPLETE THE PUNCH LIST AND CHECK OFF EACH ITEM, THEN RETURN IT TO THE INSPECTOR
FOR REINSPECTION. THE INSPECTOR WILL VERIFY THAT ITEMS ON THE WALK THROUGH ARE COMPLETED.
C. THE CITY WILL NOT MAKE THE FINAL INSPECTION UNTIL THE PHYSICAL WORK REQUIRED BY THE
CONTRACT AND APPROVED PLANS, INCLUDING FINAL CLEAN-UP AND ALL WORK ORDERED BY THE
PROJECT MANAGER, HAS BEEN COMPLETED. (SECTION 1-05.11)
D. FINAL APPROVAL OF THE PROJECT WILL NOT BE GRANTED UNTIL "AS-BUILTS" OR "DRAWING
OF RECORD" (BOTH DIGITAL AND HARD COPY) HAVE BEEN RECEIVED AND APPROVED BY THE
PROJECT MANAGER.
E. THE CONTRACTOR MUST FURNISH ALL DOCUMENTATION REQUIRED BY LAW, TO ALLOW THE CITY
OF ANACORTES TO PROCESS FINAL ACCEPTANCE OF THE CONTRACT.
10. MISCELLANEOUS:
A. AS-BUILTS/DRAWING OF RECORD: REFER TO "GEN-13 - DRAWING OF RECORD".
B. UTILITY LOCATE NUMBER: 1.800.424.5555. REQUIRED BEFORE STARTING ANY GROUND WORK.
STORM DRAINAGE NOTES
A. ALL WORK SHALL CONFORM TO THE CURRENT WSDOT SPECIFICATIONS FOR ROAD, BRIDGE AND
MUNICIPAL CONSTRUCTION, CITY OF ANACORTES DRAINAGE CODES AND ORDINANCES AND
THE CITY OF ANACORTES ENGINEERING AND DEVELOPMENT STANDARDS.
B. ALL POLY -VINYL CHLORIDE PIPE (PVC) AND FITTINGS SHALL CONFORM TO AND MEET THE
REQUIREMENTS OF THE LATEST ASTM SPECIFICATION D3034. PIPE AND FITTINGS SHALL
MEET STANDARD DIMENSION RATIO 35. PROVISIONS MUST BE MADE FOR CONTRACTION
AND EXPANSION AT EACH JOINT WITH A RUBBER RING, SECURELY PLACED TO PREVENT
DISPLACEMENT.
C. ALL CONCRETE STORM PIPE SHALL BE RUBBER GASKETED, REINFORCED CONCRETE CULVERT PIPE
CONFORMING TO SECTION 9-05.3(2) OF THE SAID APWA STANDARD SPECIFICATIONS.
D. ALL CORRUGATED POLYETHYLENE PIPES (CPEP) SHALL BE SMOOTH INTERIOR AND
MANUFACTURED FROM HIGH -DENSITY POLYETHYLENE RESIN, WHICH SHALL MEET OR EXCEED
THE REQUIREMENTS OF TYPE III, CATEGORY 4 OR 5, GRADE P33 OR REQUIREMENTS OF
AASHTO M249. ALL FITTINGS AND ACCESSORIES SHALL BE MANUFACTURED AND FURNISHED
BY THE PIPE SUPPLIER.
E. ALL 12-INCH THRU 36-INCH DIAMETER CORRUGATED POLYETHYLENE PIPE (CPE) FOR STORM
SEWER AND CULVERTS SHALL COMPLY WITH THE REQUIREMENTS OF WSDOT/APWA SECTION
9-05.19 CORRUGATED POLYETHYLENE CULVERT PIPE. JOINTS SHALL BE SOIL -TIGHT. ALL 3-INCH
THRU 10-INCH DIAMETER CORRUGATED POLYETHYLENE PIPE (CPE) SHALL COMPLY WITH ALL
THE REQUIREMENTS OF AASHTO M252 AND BE MANUFACTURED WITH A SMOOTH INTREGRAL
LINING THAT COMPLIES WITH ALL MATERIAL AND STIFFNESS REQUIREMENTS OF AASHTO
M294. JOINTS SHALL BE SOIL TIGHT AS DEFINED IN SECTION 9-05.19.
F. ALL FITTINGS SHALL BE OF LIKE MATERIAL AS THE PIPE FURNISHED BY THE PIPE SUPPLIER.
G. ALL PIPES SHALL BE SUITABLE FOR USE AS A GRAVITY DRAIN CONDUIT.
H. THE END OF THE ROOF AND FOOTING DRAIN STUB OUTS SHALL BE MARKED "STORM DRAIN" ON
A PVC PIPE.
I. THE MARKER SHALL EXTEND A MINIMUM OF 36-INCHES ABOVE THE GROUND. THE PORTION
ABOVE THE GROUND SHALL BE LABELED "STORM SEWER" WITH BLACK LETTERS. IT SHALL ALSO
IDENTIFY THE INVERT OF THE STUB.
J. CLEAN -OUTS SHALL HAVE CAST IRON CASES.
K. DRIVEWAY CULVERTS LOCATED WITHIN THE RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH
TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF
THE DITCH.
L. FOOTING DRAINS, ROOF DOWN SPOUT AND CURTAIN DRAINS ARE TO BE CONNECTED TO THE
STORM DRAINAGE OR SWALES AS SHOWN ON THE CONSTRUCTION PLANS.
M. MINIMUM SLOPE ON ROOF AND FOUNDATION DRAIN STUBS SHALL BE 0.5% AND HAVE A
MINIMUM OF 1-FOOT OF COVER. ROOF DRAINS AND FOUNDATION DRAINPIPES SHALL BE
CONSTRUCTED OF PVC ASTM D3034 SDR 35, AND ASTM F679.
N. DRAINAGE OUTLETS (STUB OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT. STUB -OUTS
SHALL CONFORM TO THE FOLLOWING:
- EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO
AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS, FOOTING DRAINS, DRIVEWAYS, YARD
DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO RENDER
LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE -FLOWING,
POSITIVE DRAINAGE TO AN APPROVED STORM WATER CONVEYANCE SYSTEM OR TO AN
APPROVED OUTFALL LOCATION.
- OUTLETS ON EACH LOT SHALL BE LOCATED WITH A SECTION OF PVC PIPE MARKED
"STORM" ON THE END OF THE PIPE AND SHALL EXTEND 36-INCHES ABOVE THE GROUND.
- DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO
CONVEY FLOWS THROUGH INDIVIDUAL LOTS.
- THE ENGINEER/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF
ALL STUB OUT CONVEYANCE LINES WITH RESPECT TO UTILITIES (E.G., POWER, GAS
TELEPHONE, CABLE, ETC.)
- ALL INDIVIDUAL STUB OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT
OWNER.
0. CATCH BASINS AT THE CURB LINE SHALL BE RECESSED 0.1 FEET.
P. ALL STORM DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES, NOT LOCATED
WITHIN A TRAVELED, PAVED ROADWAY OR CONCRETE SIDEWALK, SHALL HAVE LOCKING LIDS.
ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT DETENTION FACILITY SHALL HAVE
LOCKING LIDS. ALL DRAINAGE STRUCTURES LOCATED WITH A BIKE OR WALKING PATH SHALL
HAVE LOCKING LIDS.
Q. ALL CATCH BASIN GRATES SHALL INCLUDE THE STAMPING "OUTFALL TO STREAM, DUMP NO
POLLUTANTS".
R. CATCH BASINS SHALL CONFORM TO TYPE 1, TYPE 11, OR THE INLET TYPE AS DEFINED IN SAID
APWA STANDARD SPECIFICATIONS AND STANDARD PLANS WITH FLAT TOP FRAME AND GRATE.
S. CATCH BASINS MUST BE SET TO LINE GRADE USING NO MORE THAN TWO (2) ADJUSTMENT
RINGS.
T. THE CAST IRON FRAME MAY BE PLACED FLANGE DOWN ON THE ADJUSTMENT BLOCKS IN LIEU OF
PRECAST COLLAR. THE INSTALLATION OF CATCH BASINS SHALL INCLUDE FINAL ADJUSTMENT AS
MAY BE REQUIRED TO FINISH GRADE. INSTALLATION WITH THE PAVED ROADWAY SHALL BE
PER THE CITY OF ANACORTES TYPE I CATCH BASIN WITH 18-INCH BARRIER CURB DETAIL
UNLESS SPECIFIED AS A THRU-CURB INLET.
U. CAST IRON FRAME FOR TYPE I CATCH BASIN SHALL ACCOMMODATE; A 20-INCH X 24-INCH
GRATE.
V. A LOW PRESSURE AIR TEST AT 5 PSI FOR 15 MINUTES FOR SEWER MAINS IS REQUIRED. THE
CITY OF ANACORTES MAINTENANCE CAMERA CREW WILL VIDEO SANITARY SEWER AND
STORM SEWER MAINS. CALL 360.293.1921 TO SCHEDULE APPOINTMENT. 48-HOUR
NOTICE REQUIRED. (SECTION 7-17.3(2)H).
W. THE CONTRACTOR SHALL BE REQUIRED TO PLACE METALLIC TAPE OVER ALL NON-METALLIC
PIPES. THE METALLIC TAPE SHALL BE A MINIMUM OF 2-INCHES IN WIDTH AND PLACED
CONTINUOUSLY THE LENGTH OF THE STORM DRAIN TRENCH.
X. ALL TRENCHES FOR STORM DRAINS SHALL BE IN ACCORDANCE WITH THE SECTION 7 OF THE
CURRENT WSDOT SPECIFICATIONS FOR ROAD, BRIDGES AND MUNICIPAL CONSTRUCTION.
Y. ANY PERMANENT FLOW CONTROL FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE
MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE
ADEQUATE STORAGE CAPACITY. IF THE FACILITY IS TO FUNCTION AS AN INFILTRATION SYSTEM,
THE TEMPORARY FACILITY MUST BE GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST
THREE (3) FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY.
Z. OVERFLOW, SPILLWAY, GRAVEL FILTER WINDOWS MUST BE CONSTRUCTED PER PLANS AND
SPECIFICATIONS. NO DEVIATIONS. AS -BUILT FOR VERIFICATION REQUIRED.
AA. QUARRY ROCK MUST BE SOUND "HARD" DURABLE ROCK. NO RECYCLED MATERIAL.
BB. GRASS LINED SWALE SHALL BE CONSTRUCTED PER THE DETAILS PROVIDED. NO DEVIATIONS
ALLOWED. ALL SWALES MUST BE OPERATIONAL BEFORE ACCEPTANCE.
CC. MINIMUM 1-FOOT SEPARATION BETWEEN PIPES IN TYPE II CATCH 9ASINS.
DUST CONTROL NOTES
1. Dust control shall be maintained during construction by watering the
construction road when and where truck traffic is concentrated.
VICINITY PLAN
SCALE: 1 "=300'
1. CITY OF ANACORTES:
A. STEVEN LANGE: PROJECT MANAGER B. JUSTIN: PUBLIC WORKS INSPECTOR
OFFICE: 360.299.1983 OFFICE: 360.299.1972
CELL: 360.661.3468 CELL: 360.661.3547
FAX: 360.293.1938 FAX: 360.293.1938
EMAIL: STEVEL®CITYOFANACORTES.ORG EMAIL: JIMBOCITYOFANACORTES.ORG
C. ERIC SHJARBACK: ASSISTANT CITY ENGINEER
OFFICE: 360.293.1920
FAX: 360.293.1938
THE PROJECT MANAGER IS THE KEY PERSON OF CONTACT FOR THE CITY OF ANACORTES
REGARDING TECHNICAL AND ENGINEERING MATTERS.
THE PUBLIC WORKS INSPECTOR IS THE KEY PERSON
OF CONTACT FOR THE CITY OF ANACORTES
FOR QUALITY ASSURANCE, SAFETY, FIELD COORDINATION AND INSPECTIONS.
ANY OTHER CITY PERSONEL SHOWING IMPLIED
AUTHORITY ON -SITE SHOULD BE DIRECTED TO THE
PROJECT MANAGER. IF THE PROJECT MANAGER
IS UNAVAILABLE, THE LINE OF COMMUNICATION
SHOULD BE FOLLOWED.
B. CITY OF ANACORTES WATER DEPARTMENT
2. ADDITIONAL CONTACT INFORMATION:
TERRY NEMETH: FOREMAN
OFFICE: 360.293.1921
A. CITY OF ANACORTES STREET DEPARTMENT
BILL LARSEN: FOREMAN
COMCAST CABLE
OFFICE: 360.293.1921
Bill Inama, Construction Maintenance
C. COMCAST CABLE
CELL; 360-815-6354
CASEY JONES: NEW CONSTRUCTION
360-527-8302
EMAIL bill_inamaOcable.comcast.com
EMAIL
CELL: 425.508.7335
FAX: 360.527.8302
CASCADE NATURAL GAS
EMAIL: CASEY-JONESOCABLE.COMCAST.COM
Jim Hobbs
D. CASCADE NATURAL GAS
OFFICE: 360-336-3911
Ted McCommant
CELL 360-941-0499
OFFICE: 360.336.3842,
FAX: 360-336-2564
Cell: 360-708-4689
EMAIL james.hobbs®cngc.com
FAX: 360.336.2564
p ENERGY
SCHEDULE OF DRAWINGS
Cl Cover Sheet, Vicinity Plan
& Construction Notes
C2 Existing Site Plan
C3 Erosion Control Plan
C4 Site Improvements Plan
C5 Perk Filter and BMP Details
C6 Details
C7 Details
EMAIL: ted.mccammantOcngc.com UGET SOUND CONSTRUCTION SEQUENCE
Jane Major -Municipal Construction
E. PSE/INTOLIGHT
Planner
Lane Mahler, Project Manager
OFFICE: 360-766-5571
OFFICE: 425-462-3624
CELL 360-791-2748 1.
CELL: 425-429-1356
EMAIL- Jone.majorOpse.com
FAX: 425.462.3149
Frontrier 2.
EMAIL:- lane.mahlerOPSE.COM
Bret Murdock
OFFICE: 360-707-0641
CELL 425-417-7085
FAX: 360-757-4338
EMAIL bret.t.rrurdock®ftr.com
DEVELOPER
COMPANY NAME: Madrona Real Estate Investors
OWNER NAME: Brad Augustine
OFFICE: 206-623-7662
CELL:
FAX:
EMAIL: BradcOMadronaRealEstate.com
EERING FI
COMPANY NAME: Herrigstad Engineering PS
OWNER NAME: Dale Herrigstad
OFFICE: 360-299-8804
CELL: 360-770-2585
FAX:
EMAIL: dole®herrigstad.com
NAME: James Sullivan
OFFICE: 206-623-7662 Ext 107
CELL: 206-538-2951
FAX:
EMAIL: JamesS®MadronaRealEstate.com
MATERIAL TESTING COMPANY:
COMPANY NAME:
OWNER NAME:
OFFICE:
CELL:
FAX:
EMAIL:
NAME: TBD
OFFICE
CELL
EMAIL:
.;
INSTALL TEMPORARY EROSION CONTROL MEASURES.
COMPLETE OFFSITE STORM WATER IMPROVEMENTS.
PROJECT DATUM
NAVD88 AT TOP OF
SDMH RIM IN NE
CORNER OF
INTERSECTION NEAR
CURB AT 18TH & "0"
AVENUE.
ELEV.=30.09'
NAVD88
FIE UT Y
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anocortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
corn lionce with a plicable laws and permit requirements.
III. 1`l.l
CITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
16-2019 Rev. B, October 16, 2019
a
Ono
21;
O
O
_4
I
0
cQ
CC
54
W
CQ
w
o
CQ
z
�
a>
it
W
�
CO
y
O
_
CO
C
ra
CO
W�
0
� �
4-)
%1
0
SHEET
NO.
C1
REV.: B
JOB NO: 2018-11
DATE:
October 2019
SCALE:
Noted
DRAWN:
D. HERRIGSTAD
CHECK:
D. HERRIGSTAD
SHEET L OF
EX. SSMH
L-034
RIM=28,83'
I.E,=15,73'
SD
I
N
40,0'
I
l 28.3V
28,98'�
I x
29,441-
III
Ss
O
O
TYPE 2 SDMH
RIM ELEV,=18,74'
INV, OUT =
12' CONC. SDI SD
SD
w EXIST, TYPE1 CB
RIM ELEV: 18,82'
— — — — — — — — — — `� INV, OUT = 15.57'
— d
�i\i VL I I L1 O
RIM=21,29' �r U
I.E,=19,68'
I 1 as as I CIS I — —�--- — — I
F10 i B �fYPE1EXIST. 8" PI C SD EXI T. 8 PVC SD aI 9 IM=22,44' 7 I EX, CB 3 I 2RIM=19,,8iILE,=17,5SPARAEXIST. 8" P
I 1 I > I I I I
c I I EX, CB TY I
28,06' SS
PAVED
G I EX, CUR I EXIST. 8" j PVC SD IE 1�i 90'
SD SD
EX, CB TYPE'1-
I I J�� �� 1 1 RIM=21,96' i INGRE7AF�
�Ji I I.E,=20,81' EGRESI EX. SSMHI EASEM�� I L-034 1 j #9812SEE G
��~ I RIM=23,65' I I
--- E=1�0-------- --- I---INFORMOIDN
-----
-EXISTING ASPHALT EX. 8" PVC SS
Z26,47'SS 25.41ss NITTE_97
T SH ENCLOSURE EX, URB r--------�--- —-------I------�
GARAGE I 24,08'
cc I I
I I 23.88
HAVE
23.11'
BEEN N L I I 1
REMOVED
I � I
z 0 I j 22.87 I
q 1014 I I 7' SIDEWALK I
HOUSE I ``'_ 18TH T.
l I I I
1020 1
18TH ST,i 1 13 14 I I 15
I 2 4 I 1 1 , 19 1 20
I q 11 16 , 17 1 0 0
23.36
I x I L J I
EXIST, TYPEI CB
RIM ELEV.=19.71'
INV, BUT = 17.49
SEXIST. 8" PVC SD
40,0'
40,0'
25� 6 — -- -- --
I
Y WM PP11 26.7 '
EXIST. 6' SIDEWALK
WM
7RIM=30,09
, S MH EX, FACE OF CURB 27,25' 6,71'
28 886' 27.72 �- 27,5' 18th STRE T
4,29,
- - - S 89058'5V Q 379,63'
W
EX, 6" DI WATER
W W
GRAPHIC SCALE
( IN FEET )
1 inch = 20 ft
W
8" CMP SD
sDSD
'�--EX, CB TYPE1
a RIM=22,03'
o I.E,=20Y21'
u-�
X
TYPE1 CB
a
rTYPEl CB
LEGEND
FENCE —x x x x x—
GAS c
SANITARY
SEWER ss
STORM
SEWER SD
WATER
MAIN W
OVERHEAD POWER --oP----oP----oP----oa---
ERHEAD TELEPHONE --oT----aT----oT----oT---
SDCB ❑
SSCB 0
SSMH 0
WFH2 R
WGV N
WMET ED
FDUND MONUMENT
� WITH CASE &
COVER 5-3-2014
V1
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anacortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
Professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
com lionce with applicable laws and permit requirements.
'F-4-
1\•\9.\9
CITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
D-16-2019 Rev, B, October 16, 2019
o
I
q�
� o
�j d �T
V
W
W
c�
N
a,
I~
C j C\2
O�
CD
� O
�
O
W
�
SHEET
NO.
C2
REV.: —
JOB NO:
2018-11
July 2019
SCALE: Noted
DRAWN: D. HERRIGSTAD
CHECK: D. HERRIGSTAD
2 7
tt-��-�F� QazP4o,ww,•a--
TESC NOTES
W
HIGH VISIBILITY FENCE
ALONG PERIMETER
DOE BMP C103
40,0'
EX. 5' SIDEWALK
x
I
I
x
'a
Ix
I
x
I
x
II
a
I
x
e
I
I
LX, CB TYPEI
RIM=22,44'
Tr- —innnl
PAVED
11 PARKING
CONSTRUCTION ENTRANCE DOE
x
BMP C105
DOE FIGURE II-4.1.1.10
SAWCUT(on-o'64 EXISTING ASPHALT EX, 8' PVC
S% 28,06' /26,47'
EX. SSMH AWCUT�
L-034 C P C152)
RIM=28.83'
I.E.=15,73' 28,31' x
29, 5'
HIGH VISIBILITY FENCE x
ALONG PERIMETER44
DOE BMP C103
OR CHAIN LINK FENCE " .d
cn
00
28,98' x 00
q
Z
0
ib
X
W
U
09A4'j-
T
30�
EXIST,
RIM=3C
I.E.=24
P 55160
PARKING LOT WILL
BE STABILIZED WITH
CRUSHED SURFACING
FOR CONSTRUCTION
PARKING
1 APARTMENT 2733
BUILDING
4,432 SF 27,59'
FLOOR RISER
ELEV,=28,63' R00
2'^IRETAP59' f
G a <a
A —
Q�q---X X —�
27,70'
ra
25.4
26,93'
7,25'
C�_X
RIM=21,29'
1.E,=19.68'
ST. 8" PVC SD
EX. \CURB
3,11'
23.3
as aS
EXIST. 8 PVC SD
EX. CB TYPE1-
RIM=19,94'
IE,=OIL/
W/ OIL/WATER
SEPARATOR
EXIST. 8" PVC Q_
EX, CB TYf'F-_1-
EXIST. 8" PVC SD RIM=20,27'
IE=1790'
SD
EX. CB TYPE1 — — SD — _
RIM=21,96' INGRESS/
I.E.=20,81' EGRESS
CB INLET PROTECTION WITH EASEMENT AF
WSDOT 1-40.20-00 #9812040003
INSERT FILTER SOCK(Em?e ) SEE GENERAL
EX. SSMH INFORMATION
L-034
RIM=23,65' NOTE 9,
I,E.=16,0'
1710 COMMERCIAL AVE
11'x11'
SEDIMENT TRAP
DURING CONSTRUCTION
SEE SECTION B-B BELOW
(51y\P C'"o)
SILT FENCE
DOE BMP C233
DOE FIGURE
BMP C154
CONCRETE
WASHOUT AREA
BMP C123
COVER SOILS
STOCKPILES,
-CONSTRUCTION
JOB-SH,AUK — —
6'
MH EX. FACE F CURB 27.25'�f�„ f' R
9 27,72' SAWCUT CONSTRUCTION ENTRY
9 28,86' _ 18TH STREET BMP C105
DOE FIGURE II-4.1.1.
I(J_H VISIBILITY FENCE
ALONG PERIMETER
DOE BMP C103
w w
EX. 6" DI WATER
V
w ti
TRAP OUTLET SECTION C-C
r
E DOE
EXIST. 6' SIDEWALK
to
HIM
7' SIDEWALK
CB INLET PROTECTION WITH
WSDOT 1-40.20-00
INSERT FILTER SOCK
_ I 1' OVERFLOW DISHARGE TO STABILIZED
2'-4' n
RIPRAP CONVEYANCE
31 SIDE
SLOPE 3.5 'BOTTOM ELEV. 3:1 SIDE 1
= 285' SLOPE
FLAT BOTTOM 3/4'-1,5'
WASHED ROCK GEOTEXTILE
TYPICAL TRAP CROSS SECTION B-B - ?-ky\� Gz°ix)
SCALE: 1"=5'
.l
1' MIN, DEPTH
OVERFLOW
SPILLWAY
--,3/4'-1.5'
GEOTEXTILE WASHED ROCK
TRAP OUTLET SECTION C-C
SCALE: 1'=5'
GRAPHIC SCALE
( IN FEET )
1 inch = 20 ft.
EXIST. TYPE: CB I
RIM ELEV,=19.71'
INV. OUT = 17.49 I
�—EXIST. 8" PVC SD
40,0'
LLJ
Q
,l
u 400,
8" CMP S
p EX. CB TYPE1
RIM=22,03'
I.E.=20,21'
A. A Certified Erosion and Sediment Control Supervisor is required, The ESC Supervisor
dust have attended and Erosion and Sediment Control class within 3years from today's
date. Must provide certification card,
B, The Certified Erosion and Sediment Control Supervisor will oversee and be responsible
for all erosion control, The facilities shall be inspected daily and maintained to ensure
proper functioning, Written records shall be kept of weekly reviews and after every
significant storm event of the ESC facilities during the wet season (October 1 to April
30), Monthly reviews during the dry season (May 1 to September 30). Written records shall
be turned into the Project Manager or Inspector on a weekly basis at the weekly
scheduled project meetings.
C. Shall be in place per the approved set of plans prior to any construction start,
D. The erosion control shall be inspected once a day and modified to meet the surrounding
conditions as needed,
E. Provide a sign displaying a 24-hour contact number and name of the ESC Supervisor,
The letter size shall be a minimum of 2' letters, This shall be in place prior to
construction start. Remember, the look of the sign will be a reflection of the Contractor
and Developer and Development,
F. The storm drain system and existing ditches shall be cleaned daily (Section 707,3), All
drainage systems shall be cleaned to the acceptance of the City of Anacortes prior to
acceptance of the project,
G. Stabilized construction entrances and roads shall be installed at the beginning of
construction and maintained during the duration of the project, Additional measures may
be required such as wash pads to ensure that all paved areas are kept clean, No mud is
allowed to enter onto City streets,
H. Any soils exposed that will not be disturbed for two (2) days during the wet season or
seven (7) days in the dry season shall be immediately stabilized with the approved ESC
methods (seeding, mulching, plastic covering, etc,)
I, Two (2) weeks prior to the beginning of the wet season (October 1), all disturbed areas
shall be reviewed to identify which ones can be seeded in preparation for the winter
rains. Disturbed areas shall be seeded within one (1) week of the beginning of the wet
season, A sketch map of those areas to be seeded and those areas to remain uncovered
shall be submitted to the Project Manager, The Project Manager can require seeding in
additional areas in order to protect surface waters, adjacent properties or drainage
facilities,
J, Penalties for an Erosion Control violation are subject to a $300 to $1000 fine under
Chapter 17,66 - Penalties for Violation, Each day is considered a different violation,
K, Remove all temporary erosion control measures when the site is landscaped and soils
are stabilized,
L. All Dewatering shall dischage into a sediment trap or sediment pond.
M. The contractor is to provide to the city inspector their spill prevention program to
be inplace during construction.
N, A sign shall be posted at the pro jext site that complies with AMC chapter 17,40,060(E)
regulating signage within the City of Anacortes, The sign shall advertise the name and
phone number of the Contractor who is accessible 24/7 to handle complaints,
0, Work hours are limited to 7+00 AM to 10:00 PM, Sunday to Saturday. No work outside
these hours are permited.
0
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anocortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
compliance with applicable lows and permit requirements.
Q,cc�pt�� /as uo�
CITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
D-16-2019 Rev, B, October 16, 2019
z
0
o
q
v�
a
I
M
CRC,P4�
o
rl�^l
WQ�
A
��
cat
CC
E�
M
04w
Q4
W
Cn
W
x�o
��
W
a)
~
f,
a)
.>
a)
-6-.)
�
W
y
�00
o
+"--'
C\2
~
co
Cn
�GZ
Cn
O
T
Q
c�
O
G�
o
^r—�
CJ
o
�
'n
.
7=1
o
�
W�
SHEET
NO.
C3
REV.: -
JOB NO: 2018-11
DATE:
Oct. 2019
SCALE:
Noted
DRAWN:
D. HERRIGSTAD
CHECK:
D. HERRIGSTAD
SHEET.!! —OF
40,0'
I
6,5'
S IV-
z
Q
O
DRIVEWAY EN Ct
WSDOT STND PLAN
F-60,10-03 TYPE 4
EX, SSMH --�
L-034
RIM=28,83'
I,E,=15,73'
BMP T513 POST
Mimi
EXT�Vg2P Slpe IpL A1�r (� yd LJ�
WILL.L-Al2—
�r��pLk
�S"t'v.N(�t�.eo A.-tit-� (Y-4o.15-031
�Mt%--•D Tb GIT'� �c�1�\R.�w1�7CS
d- W
EX. FIRE HYDRANT
I O REMOVE EXIST, BLOCK
I WALL TRASH
ENCLOSURE
Q
QI
`� I NEW SSMH
O(NDOGHOUSE O
USE MH)
47,5M15,8;o 18' S5 LF PVC STO BLDG WITH
IRON LID
- L
SS —
I
CONSTRUCTION SOILS ON i
ALL NEW GRASS AND
LANDSCAPING AREAS.
�Z
r
I � d
X
W
SECTION A -A
SHOWN BELOW
PERPENDICULAR CURB,6,5
RAMP B WSDOT STND
PLAN F-4015-03
— SEXIS , SDMH
RIM= 0109'
I,E,=2 ,29'
11
EXISTING
17th STREET
W W W
REMOVE
NEW 5' STORM DRAIN EASEMENT EX. CB TYPEI ®r(2) WM
RIM=21,29'
CB TYPE1 I.E.=19,68'
RIM=22,44'
POLE
REPLACE WITH 48 LF 12'
CPEP SD
SLOPE=0,005 FT/FT
180 LF 12' CPCP SD
SLOPE=0,005 FT/FT
W
EX. 12' CONC. ST
TYPE 2 SDMH
EXIST, TYPEI CB RIM ELEV,=18.74' qr:�TYPEI CB
x RIM ELEV.=18,82' rn
co INV, OUT
� 3
o WA VALVE
EX, 12" AC WA EPLACE Tl C TYPEI CB
EXIST�TYPE1 CBRIM=19,01'
RIM ELEV,=19,01' I,E,=15,81'
INV, OUT = 17.46I
0 1
— —
INV,=18,47' -
—
- ` - - - -
- - -
POLE
12 LF 12 CPCP
SD
-
--
as - - - - - -
- _
SLOPE=,0050
____
EX. CB TYPEI
EXIST. 8 PVC SD EXIST.
_
13s LF 8" PVC SD S=1.51% EX,
____--
CB TYPEI
PERKFILTER
1
RIM=22,44' I
RIM=19,94'
STEEL CATCH
BASIN
GIs walk IS %oe�
,E,=19,84' I I
EPLACE
NEW 5 WIDE STORM
LE.=17,57'
FOUR CARTRIDGE
o
vNOP� L�NoCti� Sw\Ol�h
I I
DRAINAGE EASEMENT OVER
W/
OIL/WATER
RIM = 19.94'
I
\T-
LF 12'
I
EXISTING STORM LINE AND
SEPARATOR
I
I.E. = 16,00' OUT
C EP SD I
Q
LE, IN = 17,5
'
I NEW EXTENSION TO PARCEL EXIST. 8" PVC SD
SL PE=0,005 I N I P55161
I I EX. CB TYPEI
I i EX. CURB EXIST. 8" PVC SD RIM=20,27'
I SD LE.=17,90
CB YPEI I I O —SEX. CB TYPE1 - - S—� -
I RIM=21.96' INGRESS/
INV, B 86' I ��O ° I.E,=20,81' EGRESS
EX, SSMH EASEMENT AF
L-034 #9812040003
36 " `�,� RIM=23.65'
CPEPF D ��~ I.E.=16,0' SEE GENERAL
SLL0P� INFORMATION
GA VALVE \ NOTE 9,
�IAIl_1}(. 8' PVC SS
i—�- 21, S S
C,O, GAS
POWER METER
METERS
MOM L
�i -
\
'
\
1 C
1BELOW
V 21' 01
19,
CU o
\ 10' �—� 27,2 26,93'
7,06'
2' RETAIS91
SJI}EWALK 27,70' Ly rWM 8,5' PF
EX. FACE OF CURB '- 19' -' DRIVEWAY ENTRANCE
WSDOT STND PLAN
-PROVIDE 18 T H S T R E E T F-80,10-03 TYPE 4
INV:
28,63' ELEV�
19, 41'
'A PARTMENT
BUILDING 21.33
00 27,59'-
4C co,432 SF
FLOOR RISEI
ELEV,=88,63' ROOM
SIDEWA K GUY'
WIRE O ER
SIDEWAL
W
I"*
EX 6" DI WATER W
REMOVE WATER METER
AND DISCONNECT AT
MAIN
4' WATER TAP FOR FIRE REMOVE WATER METER
SURVICE LINE AND DISCONNECT AT
W/ 4' DI VALVE MAIN
AND 2' TAP FOR DOMESTIC
WATER LINE WATER METER
SIZE TO BE DETERMINE BY
CITY
SCALE: 1'=20' HORIZONTAL/ 1'=10' VERTICAL
EXTRUDED
CURB
I
I
1710 COMMERCIAL AVE
GRAPHIC SCALE
W
Q
40,0'
EXIST. 6' SIDEWALK I
w
B
SCALE: 1'=20' HORIZONTAL/ 1'=10' VERTICAL
// 8" CMP D
s� '--EX, CB CB TYPEI
RIM=22.03'
I.E.=20.21'
LEGEND
FENCE
GAS
SANITARY
SEWER
SS -
STORM
SEWER
SD
WATER
MAIN
W
OVERHEAD POWER
—OP — — — — OP — —
_RHEAD TELEPHONE
— pT — — — — OT — —
SDCB ❑
SSCO a
SSMH
WFH2 A
WGV D4
WMET ES
CURB/GUTTER AND SIDEWALK WORKMANSHIP AND AESTHETICS
1. CURB/GUTTER AND SIDEWALK CONSTRUCTION SHALL FOLLOW A TRUE AND
UNIFORM HORIZONTAL AND VERTICAL ALIGNMENT.
2. THE VERTICAL AND HORIZONTAL SURFACE SHALL BE A SMOOTH BROOM
FINISH WITH NO DETECTABLE FINISHING BLEMISHES, UNDULATIONS, RIPPLES,
SWELLS, WAVES, RUTS, FURROWS, GRAFFITI OR OTHER OBJECTIONABLE MARKS.
THE END RESULT SHALL BE A NEAT AND PROFESSIONALLY FINISHED
APPEARANCE.
3. THE EDGE FINISH ADJACENT TO THE EXPANSION JOINT MATERIAL SHALL BE
CLEAN AND FREE OF EXCESS SLURRY. THE EXPANSION JOINT MATERIAL SHALL
BE TRIMMED TO A LEVEL EVEN WITH THE ADJACENT CONCRETE RESULTING IN
A NEAT AND PROFESSIONALLY FINISHED APPEARANCE.
4. THE CITY ENGINEER IN HIS SOLE DISCRETION RESERVES THE AUTHORIY TO
ORDER THE REMOVAL OF SECTIONS OF CURB/GUTTER AND SIDEWALK THAT DO
NOT MEET THE WORKMANSHIP AND AESTHETIC STANDARDS OF THE CITY OF
ANACORTES.
5. SECITONS OF NEWLY CONSTRUCTED CURB/GUTTER AND SIDEWALK THAT
EXHIBIT CRACKING FOLLOWING THE CURING, SHALL BE SUBJECT TO REMOVAL
AND REPLACEMENT.
- CRACKING RESULTING FROM SUB -BASE FAILURE OR CONSTRUCTION SITE
DAMAGE SHALL BE IMMEDIATELY REMOVED AND REPLACED TO THE NEAREST
EXPANSION JOINT.
- MINOR HAIR LINE STRESS CRACKS MAY, AT THE DISCRETION OF THE
PROJECT MANAGER, BE MONITORED AND RE-EVALUATED FOR POSSIBLE
REMOVAL AT THE END OF THE MAINTENANCE PERIOD.
FOUND MONUMENT
WITH CASE
___7
/ 3�p(�vES'r ��KII-16 SPvcES Tb Fes. �vlo� d.La-lV �b iSJt�.,uE.,
�7� L I`1.(�1 p36 - b40- �rC �ill_DIN% F�mcC SITE F1 l
A7..0) SIoN (I.OS-19
I
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anacortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
compliance with applicable laws and permit requirements.
A�-r�-e as Now -
� I1 IS.I�i
UITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
14-2019 Rev,C, November 14, 2019
�.
o
� I
q W a cQ
a o
� ao�
Cn
F� cf I
w�
W x�o
o �
W
m
a>
a
O^
�
�
rrTT�
O
SHEET
NO.
C4
REV.: -
JOB NO: 2018-11
DATE:
Oct 2019
SCALE:
Noted
DRAWN:
D. HERRIGSTAD
CHECK:
D. HERRIGSTAD
SHEET 4 OF 7
w
E—
Q
h
PLAN VIEW
(INTERNALS NOT SHOWN FOR CLARITY)
SCALE 314' - V-0'
e1e'XY DEEP KNOCKOUT -TO BE
REMOVED BY CONTRACTOR FOR PIPING
DO NOT USE THIS
END KNOCKOUT
ra 4'
VIEW D
(INTERNALS NOT SHOWN FOR CLARITY)
SCALE 3W = T-O'
N
STAII
WEIR WALL
STAINLESS STEEL
BAFFLE HOOD
PIPE TO BE FULLY
GROUTED AFTER
INSTALLATION
STAINLESS STEEL n
WEIR WAIL
on NOT USE THIS
END KNOCKOUT
DO NOT USE THIS
END KNOCKOUT
SECTION F-F (INTERNALS)
SCALE: 3t4' = V-D'
SECTION G-G (INTERNALS)
SCALE: 3W = V-O'
LOW ROW OPENING TO
CARTRIDGE CHAMBER
DO NOT USE THIS
SO KNOCKOUT
HOLD DOWN
DESIGN NOTES:
BAR
1.
DESIGN LOADINGS:
1K 19' PwkFlb1®
A HS-20 TRUCK WHEEL LOAD WI IMPACT.
CARTRIDGE STACK
B. SOIL DENSITY: 120 PCF(AWNED).
C. WATER TABLE: TOP OF STRUCTURE
(ASSUMED).
D. DRY LATERAL EARTH PRESSURE (EFP) : 40
PCF.
E. LATERAL LIVE LOAD SURCHARGE: 80 PCF.
2
CONCRETE:
A 28 DAY COMPRESSIVE STRENGTH: fc =
5,000 PSI.
3.
REINFORCING:
A. REBAR: ASTM A-615 OR A-706 GRADE 60.
B. MESH: ASTMA-1064 GRADE 65.
4.
CEMENT: ASTM C-150.
5.
DESIGN SPECIFICATIONS & CODES:
A ASTM C-858, ASTM C-913.
B. ACI-316 BUILDING CODE.
6.
PRECAST DESIGN DOES NOT INCLUDE ANY
LATERAL OR SURCHARGE LOADS FROM
OTHER BUILDING OR FOUNDATIONS
ADJACENT TO THIS STRUCTURE. THIS
STRUCTURE SHALL BE KEPT A MINIMUM OF 1:1
RATIO AWAY FROM OTHER FOOTINGS OR
FOUNDATIONS.
CONTRACTOR NOTES:
1.
OLDCASTLE TO PROVIDE & INSTALL ALL
INTERNAL COMPONENTS(SOME COMPONENTS
NOT SHOWN).
2.
CONTRACTOR TO PROVIDE CRANE AND RIGGING
CAPABLE OFF LIFTING WEIGHTS SHOWN.
3.
FRAMES MAY BE ADJUSTED TO GRADE Wl
NON -SHRINK GROUT.
Treatment Flow Rate
10.2 gpm / 0.023 cfs
Total Flow Capacity 1.3 cfs
Stormwater
Figure 11-4.1.7b Concrete Washout Area
Strew bale
10 mi plastic lining
SntwiB Native material
(2 per Deb) (Optional)
Wood or
meta stares
(2 par bast)
Section B-B
f�-- 3m Minimum
Stake
Bt
Varies
Straw bale J
(tYP )
Plan
Binding wire
Plywood
1200 mm x 610 mm Wood post
painted white (89 mm x 89 mm
Lag screws x2.4 m)
(12.5 mm) c: i Black letters
i1oncR wnsNouTtl 150 mm height
915 mm 11
91155 mm
Concrete Washout Sign
Detail (or equivalent)
�B
�-- 10 trill pleeflo lining
50 mm
200 mm 3.05 mm dia.
steel wine
Staple Detail
Notes:
1. Actual layout
determined in the laid.
2. The concrete wasbo t
sign shall be Installed
within 10 m of the
temporary concrate
washout facility.
T "Above Grade" with Straw Bales
Figure 11-4.1.7b
Concrete Washout Area
NOT TO SCALE
DEPARTMENT OF Revised June 2015
ECOLOGY Please we h*:IAvww.eoy.wa.gdv/copyrA ftW for copyright notice including permissions,
State of Washington lhrHt tan of Habiliy, and disdeimer.
2014 Stormwater Management Manual for Western Washington
Volume 11- Chapter 4 - Page 323
Figure 11-4.1.1 Stabilized Construction Entrance
d
�XTsa�Roa
Insw driveway
aivert If Mere is a
roadside ditch present
Notes:
1. Driveway shall meet
the requirements of the
permitting agency.
2. N is recommended that
the entrance be
dawned So that runoff
drains off the pad.
4' - 8' quarry
spells
GeotexNle
12' minimum thickness
100' min
NOT TO SCALE
Figure II-4.1.1
Stabilized Construction Entrance
DEPARTMENT OF Revised June 2015
ECOLOGY Please see hdp pwww acy m goHcop),dghthhnl for copyright notice including permissions,
State of WaShinglonj fsilalion of liability, and disclaimer.
2014 Stomlwater Management Manual for Westem Washington
Volume 11- Chapter 4 - Page 273
Figure 11-4.2.12 Silt Fence
Joints in filer fabric shall be spliced
at posts. Use staples, Wine rings or
equivalent to attach fabric to posts
2')0 by 14 Ga. wire or equivalent,
If standard strength fabric used
--� rr--------_.....,-------- rl
MlNmlxmh I g iTim I I
Tom- �7I
4'x4•tranch I I I I
Poet apeckg may be Increased
108' d wire bacldng is used Yxr wood posts. steel
farce posts, or equivalent
2YY by 14 Ga. Wire or equivalent,
if standard strength fabric used
Filter fabric
Seddia bench with
nellve sod or-
1.5• waded gravel
I
2'min
lArdmurn
4'x4•trench J/LJ
2-YZ wood posts, steel
fence posts, or equivalent NOT TO SCALE
Figure II-4.2.12
Silt Fence
DEPARTMENT OF Ravised October 2014
ECOLOGY Please see hNpy/www.ecy.wa.gov/copyrlghthrml for copyright notice Including permissions,
State of Washington Bnnitation of liability, and disclaimer.
2014 Stormwater Management Manual for Western Washington
Volume ll - Chapter 4 - Page 369
k►�J
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anocortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
coon fiance with applicable laws and permit requirements.
0114.15
CITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
Rev, B October 16, 2019
V
�
O
cc
qw
a
C\2
�
�
r _
.--I
E�
x
�1
w
�
I�
O
a
rn
y�
rn
a>
�
Cd
cc
oa
to
�N
F2
R
s.:
O
`d
^�
SHEET NO.
C5
REV.: -
JOB NO: 2018-11
DATE: July 2019
SCALE: Noted
DRAWN: D. HERRIGSTAD
CHECK: D. HERRIGSTAD
SHEET 5 OF
G
LANDING
GRADE BREAK
SEE CONTRACT PLANS -
4' - O" MIN.
CEMENT CONCRETE
SIDEWALK- SEE NOTE 5
2.0% MAX.
FLARE (TYP.)
NOTES
CURB RAMP WIDTH 4'- O" MIN. LANDING TO MATCH
q
CURB RAMP WIDTH -SEE CONTRACT PLANS
CURB RAMP WIDTH 4'- W MIN.
1.
Provide a separate Curb Ramp for each marked or unmarked crosswall
LANDING TO MATCH CURB RAMP
WIDTH - SEE CONTRACT PLANS
Curb Ram location shall be laced within the width Of the associated
P P
GRADE BREAK LANDING
crosswalk or as shown in the Contract Plans.
SEE CONTRACT PLANS - CURB RAMP
4' - O" MIN.
GRADE BREAK
2•
Where "GRADE BREAK" Is called Out, the entire length of the grade
CEMENT CONCRETE SIDEWALK -
break between the two adjacent surface planes shall be flush.
SEE NOTE 5
PROVIDE SMOOTH
TRANSITION TO
SIDEWALK
2--0-
3.
Do not place Gratings, Junction Boxes, Access Covers, or other appurtt
SEE CONTRACT PLANS -
WIDTH (TYP.)
MIN.
SEE CONTRACT PLANS -
nances In front Of the Curb Ramp or on any part Of the Curb Ramp Or
4' - O" MIN.
2.0�
MAX.
4' - 0' MIN.
Landing.
3/8" EXPANSION
JOINT (TYP.) -SEE �.
BUFFER WIDTH -MATCH TO
CURB RAMP DEPTH (TYP )
See the Contract Plans for the curb design specified. See Standard PI,
3/8' EXPANSION CURB RAMP STANDARD PLAN F-30.10 v 4. g P
JOINT (TYP.) - SEE v �,, F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and
TANDARD PLAN F-30.10 GRADE P
J � BREAK TRANSITION TO SIDEWALK BUFFER, IF� Pedestrian Curb details.
GRADE BREAK PRESENT, OR TO BACK OF CURB (TYP.) -
�� ,o ° SEE CONTRACT PLANS 5 See Standard Plan F-30.10 for Cement Concrete Sidewalk details.
CURB, OR CURB
AND GUTTER -
SEE NOTE 4
FACE OF CURB
MEASURED PARALLEL
TO CURB (TYP.)
SLOPE TREATMENT -
SEE STANDARD PLAN F-30.10
.0%MAX. EiEiiEEEi ii•.^ir.i 10.0%MAX-
See Contract Plans for width and placement of sidewalk.
......... ..::: •:: :..:.:..
CURB, OR CURB CEMENT CONCRETE
- AND GUTTER - PEDESTRIAN CURB - 6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include
DETECTABLE WARNING SURFACE - SEE NOTE 4 D SEE NOTE 4 the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter,
SEE STANDARD PLAN F45.10 DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F-45.10 Pedestrian Curb, Or Sidewalk.
FACE OF CURB
DEPRESSED CURB AND GUTTER -
CROSSWALK SEE NOTE
L
PLAN VIEW
TYPE PERPENDICULAR A
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F45.10
4'- 0" MIN. 1 ' - "MAX.
SEE CONTRACT PLANS SEE NOTE 7
2.0% MAX. GRADE BREAK
8.3% MAX,
LANDING J CURB RAMP J a
SECTION OA
ALL SIDEWALK RAMPS TO BE STAMPED PER
ST-06 OF THE COA EDS STANDARDS, THE DWD
ARE EITHER BLACK AND WHITE OR COLOR,
DEPRESSED CURB AND GUTTER 7• The Curb Ramp maximum running slope shall not require the ramp lenl
CROSSWALK to exceed 15-feet to avoid chasing the slope indefinitely when connectil
to steep grades. When applying the 15-foot maximum length, the runnil
slope of the Curb Ramp shall as flat as feasible.
$• Curb Ramp, Landing, and Flares shall receive broom finish. See
PLAN VIEW LEGEND Standard Specifications 8 14.
TYPE PERPENDICULAR B EIN EITHER DIRECTION
(SHOWN WITH BUFFER) CEMENT CONCRETE DETECTABLE WARNING SURFACE -
PEDESTRIAN CURB - SEE STANDARD PLAN F45.10
GRADE BREAK SEE NOTE 4
COUNTER SLOPE -
5.0% MAX. 3' R TYP DEPRESSED CURB AND GUTTER -
SEE NOTE 4
TOP OF ROADWAY
CEMENT CONCRETE CURB
D,
AND GU ER -SEE NOTE 4
DEPRESSED CURB AND GUTTER -
SEE STANDARD PLAN F-10.12 CURB RADIUS DETAIL O
CEMENT CONCRETE CURB RAMP "TYPE
'MIT - SEE NOTE 6 A\
ISOMETRIC VIEW
TYPE PERPENDICULAR A PAY LIMIT
ISOMETRIC VIEW
TYPE PERPENDICULAR B PAY LIMIT
PERPENDICULAR
CURB RAMP
STANDARD PLAN F-40.15-02
6120113
ALL TRAFFIC CURBS TO BE CONSTRUCTED TO WSDOT STNDARD PLAN
F-10,12-03 "CEMENT CONCRETE TRAFFIC CURB AND GUTTER",
2 Z BROOMED VARIES 3/8" (IN) EXPANSION JOINT (TYP.) -
FINISH (TYP.) (SEE CONTRACT PLANS) SEE STANDARD PLAN F-30.10
2.0°/D MAX. MATCH SIDEWALK WIDTH
CONCRETE
CEMENT 0. \\\\\��\�.
� (SEE CONTRACT)
SIDEWALK . MATCH SIDEWALK WIDTH
(SEE CONTRACT) 6' - 0" VARIES 6'- 0'
(SEE CONTRACT)
3/8" (IN) EXPANSION JOINT (TYP.) - -
"'r SEE STANDARD PLAN F30.10 F-
L)\\�\\ \ \ FINISH (TYP.)
Z .r Z
O
J" LU W \
Wr LU \
(SEE NOTE 1) 2' -6- 2' - 6" CEMENT CONCRETE DRIVEWAY ENTRANCE (SEE NOTE 1) CEMENT CONCRETE
BUFFER STRIP (TYP.) E (TYP) (TYP) CURB & GUTTER SIDE SLOPE (TYP.) F CURB & GUTTER
(SEE NOTE 3) (SEE NOTE 3)
PLAN VIEW DRIVEWAY ENTRANCE PLAN VIEW
TYPE 3 SIDE SLOPE (TYP.) TYPE 4
SEE RAISED EDGE
DETAIL - THIS SHEET
1`I
ALL CUT MIN.
SLOPES
2.Oq
1J Oa - /
SIDEWALK
(SEE CONTRACT)
112 (IN) R. (TYP.)
e 2 0% MAX.
3/8" (IN) PREMOLDED
JOINT FILLER
WITH RAISED EDGE
SIDEWALK
(SEE CONTRACT)
1/2' (IN) R. (TYP.)
1 2.0% MAX.
a 3/V (IN)
PREMOLDED
JOINT FILLER
ADJACENT TO CURB
(STEEP FILL SLOPES)
SIDEWALK
(SEE CONTRACT)
- 112- (IN) R. (TYP.)
`v 2.0% MAX
3/8' (IN) PREMOLDED
JOINT FILLER
ADJACENT TO CURB
FOR SIDE TREATMENT SIDEWALK 6 1/2" 8(ii) 6 112"
SEE OTHER SIDEWALK SECTIONS (SEE CONTRACT) CONTRACTION FACE OF CURB
JOINT 51/2" 1"
CURB NOT INCLUDED IN BID ITEM -
SEE STANDARD PLAN F-10.12 1 2.0% MAX 'v
D
OFINISHED GRADE 1" (IN) BELOW
TOP OF CONCRETE SURFACE
CURB NOT INCLUDED IN BID ITEM -
SEE STANDARD PLAN F-10.12
WALL OR BARRIER
1/2"(11J1 R.
CURB NOT INCLUDED IN BID ITEM -
SEE STANDARD PLAN F-10.12
D D io ROADWAY
1' (IN) R.
D
SEE CURB FACE DETAIL D
MONOLITHIC CEMENT CONCRETE D
CURB AND SIDEWALK 6^ s 1/z^ t^ O
NOTE I -
CURB FACE DETAIL
1. Four feet of the sidewalk width shall be the minimum pedestrian accessible W
route free of vertical and horizontal obstructions. Gratings, Access Covers, EXTEND SIDEWALK TRANSVERSE EXPANSION
Junction Boxes, Cable Vaults, Pull Boxes and other appurtenances within the JOINTS TO INCLUDE CURB (FULL DEPTH)
sidewalk must have slip resistant surfaces, be flush with surface, and match d'
grade of the sidewalk. O
3/8" (IN) PREMOLDED
JOINT FILLER
SIDEWALK ADJACENT TO WALL DETAIL
DGE OR PEDESTRIAN
RAILING
BARRIER - SEE _
-\`
_ SIDEWALK
CONTRACT PLANS
(SEE CONTRACT)
-
1/2" (IN) R. (TYP.)
CURB NOT INCLUDED IN BID ITEM -
FLUSH -i
`v
2.0% MAX.
SEE STANDARD PLAN F-10.12
VERTICAL WALL - _/�
3/8" (IN) PREMOLDED
SEE DETAIL
JOINT FILLER (TYP.)
ADJACENT
TO CURB AND RAILING OR
WALL
T-O" MIN.
SIDE TREATMENT
SIDEWALK
BUFFER STRIP
OTHER SIDEWALK
(SEE
CONTRACT)
(SEE CONTRACT)
SECTIONS
1
1/2" (IN) R.
CURB NOT INCLUDED IN BID ITEM -
a
2.0% MAX.
(TYP.)
SEE STANDARD PLAN F-10.12
FINISHED GRADE V (IN) BELOW TOP OF CONCRETE
SURFACE FOR PLANTING - FLUSH IF PAVED
ADJACENT TO BUFFER STRIP
1/2" (IN) R. (TYP.) MATCH SIDEWALK WIDTH (SEE CONTRACT)
(SEE CONTRACT)
DRIVEWAY ,Il-� I 1/2" (IN) LIP BETWEEN
(SEE NOTE 7) IL 2.0% MAX `O.( ROADWAY GUTTER & CURB
(OR SEE CONTRACT)
SIDEWALK
DRIVEWAY DEPRESSED
3/8" (IN) EXPANSION JOINT (TYP.) - RAMP CURB &GUTTER
SEE STANDARD PLAN F-30.10 (SEE NOTE 3)
SECTION O
"CEMENT CONCRETE DRIVEWAY
ENTRANCE TYPE 3" PAY LIMIT
DRIVEWAY
(SEE NOTE 7)�
CL. 4000 CONCRETE
PER STANDARD SPEC. 8.06.3
ISOMETRIC VIEW
TYPE 3
'CEMENT CONCRETE DRIVEWAY
ENTRANCE TYPE 4" PAY LIMIT
DRIVEWAY
(SEE NOTE 7)
CL. 4000 CONCRETE
PER STANDARD SPEC. Ill
THIS ENTRANCE TYPE SHALL NOT BE USED ALONG A PEDESTRIAN ROUTE
1/2" (IN) R. (TYP.)
DRIVEWAY J
(SEE NOTE 7) DRIVEWAY
RAMP SECTION O
1/2" (IN) LIP BETWEEN
ROADWAY GUTTER & CURB
(OR SEE CONTRACT)
DEPRESSED
CURB & GUTTER
(SEE NOTE 3)
WSDOT STND PLAN F-80.10-03
ISOMETRIC VIEW CEMENT CONCRETE
TYPE DRIVEWAY ENTRANCE
TYPES 3, & 4
SHEET 2 OF 2 SHEETS
6111114
DRAINAGE GRATE
GRATE FRAME
IR!
SEDIMENT AND DEBRIS
DRAINAGE GRATE
- RECTANGULAR GRATE SHOWN
U11
BELOW INLET GRATE DEVICE
FILTERED
WATER
NOT TO SCALE
TRIM
will service.
a d
collected material.
OVERFLOW BYPASS
BELOW INLET GRATE DEVICE
"
cc
GI
I
qw a
0" C BROOMED FINISH (TYP.)
0" A E 4" (IN) WIDE, SMOOTH -TROWELED
t2 PERIMETER [ Q CO
�+ CEMENT CONCRETE CURB �( rZ4* d'
4 G (CURB AND GUTTER SHOWN) C:I, O
" NOT INCLUDED IN BID ITEM
SEE STANDARD PLAN F-10.12 CQ
4 E� � 03
OWN
O
E � i
\ W E-•� �
CONTRACTION JOINT
IN SIDEWALK ONLY
W O
LEVEL 1/L"
FF F�q EXPANSION JOINT IN BOTH
1/2" (IN) R. 2a�� CURB AND SIDEWALK A
`v
D
m
ISOMETRIC VIEW
D '
RAISED EDGE DETAIL
EXTEND SIDEWALK TRANSVERSE
JOINTS TO INCLUDE RAISED EDGE
f
op p p.
PREMOLDED
JOINT FILLER
EO EXPANSION JOINT
1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it
2, The BIGD shall have a built-in high -flow relief system (overflow bypass).
3. The retrieval system must allow removal of the BIGD without spilling the
4. Perform maintenance in accordance with Standard Specification 8-01.3(15).
RETRIEVAL SYSTEM (TYP.)
STORM DRAIN INLET
OVERFLOW BYPASS (TYP.) PROTECTION
STANDARD PLAN
1-40.20-00
C�J
JOINT AND FINISH
DETAIL
1/8'TO1/4" CEMENT CONCRETE
SIDEWALK
STANDARD PLAN F-30.10-03
"p p SHEET 1 OF 1 SHEET
6111114
(Z)CONTRACTION JOINT
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anocortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
complIkInce with applicable laws and permit requirements.
�- 11.1q,1�
CITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
16-2019 Rev, B, October 16, 2019
U
a
a
N
D
4-)
C-4
F,
Zj
C\2
CQ
°'ate
N
moo+
V 1
�It
Fi
•--1
r�
SHEET NO.
C6
REV.: -
JOB NO: 2018-11
DATE: July 2019
SCALE: Noted
DRAWN: D. HERRIGSTAD
CHECK: D. HERRRIGSTAD
SHEET 6 OFJ
0
0
e.
i e
SEWER C
SEWER ; •
• e•
y'e
a '
• e e • •e n • G�� F�O� •e •e
o OUTSIDE PAVED AREAS
0
PAVED AREAS J.
D B
rU
n < 3
2' d. _
LEGEND: b
A. MANHOLE RING AND COVER PROFILE
B. EXISTING SURFACE
C. 3000 P.S.I. CEMENT CONCRETE PERIMETER SEAL
D. INSTALL PRECAST ADJUSTMENT RINGS OR
CONCRETE BLOCKS AS NECESSARY TO MATCH
FINAL GRADE.
NOTES:
1. THE CONCRETE SHALL CONFORMING TO THE CURRENT WSDOT 9-03.1(4) AND BE 5.5 SACK MIX.
(MINIMUM 3000-PSI 28-DAY STRENGTH.
2. WHERE DEPTH OF NECK EXCEEDS 24 INCHES, ADJUST MANHOLE TO GRADE BY INSERTING A NEW MANHOLE
BARREL SECTION BETWEEN THE CONE AND EXISTING BARREL.
3. ADJUSTMENT RINGS/BLOCK SHALL BE SET IN 3/4" NON -SHRINK GROUT, PLASTER SMOOTH INSIDE AND OUT.
4. STEPS OR RUNGS SHALL BE ADDED AS NEEDED.
5. PRECAST ADJUSTMENT RINGS SHALL BE CAST WITH GROOVE TO ALLOW FIELD INSTALLATION OF SAFETY STEP.
6. MORTAR SHALL BE PLACED BETWEEN EACH LEVEL OF ADJUSTMENT CONCRETE BLOCKS, ADJUSTMENT RINGS,
TOP OF CONE SECTION AND BOTTOM OF IRON RING.
7. THE CONCRETE PERIMETER SEAL SHALL EXTEND TO 12 INCH MINIMUM OR 2 INCHES BELOW THE BOTTOM
OF THE ADJUSTMENT RINGS OR BLOCKS.
S. THE UnLffV SHOWN IS A SANFFARV SEWER MANHOLE LI IL1TY CASINGS LIKE WATER VALVES, MONUMENTS, GAS VALVES, ETC. WILL
FOLLOW THE SAME PROCEDURE AND GUIDELINES.
SCALE: NOT TO SCALE �%IV 0" DETAIL: ST-02
DRAWN BY: S.L.
FILE: ST-02 STRUCTURE ADJUSTMENT.DWG STRUCTURE ADJUSTMENT
EFFECTIVE DATE: REVIEW BY DATE: REVIEWER: . AND PERIMETER SEAL
,01-20-2005 05-31-2013 BUCKENMEYER �'a 0
`4� PPENDIX A - STANDARD DRAWING 2009
SIGN POST - 2 1/4" (IN)
SQUARE, 12-GAGE
STEELTUBE
o
SIGN POST - 2" (IN)
o
OR 2 1/4" (IN) SQUARE,
N F
12-GAGE STEEL TUBE z
0r.
Z
g W
,N.
III
W TOP OF LOWER
G �
z SQUARE TUBE
FINISHED
H °-
w FINISHED
GROUND
LINE��!
J
w :
0) E
m GROUND
.r LINE
SIGN POST - 2" (IN),
2 1/4" (IN), OR 2 1/2^ (IN)
a SQUARE, 12-GAGE
W STEELTUBE
0
Z
w
W
FINISHED
GROUND
LINE
PUBLIC EASEMENTS
0
O
PAVED STREET
SCALE: NOT TO SCALE
DRAWN BY: S.L.
FILE: ST-01 UTILITY TRENCH TYPICAL.DWG
EFFECTIVE DATE: REVIEW BY DATE: REVIEWER:
01-20-2005 05-31-2013 BUCKENMEYI
x
N W
In x
5 N
O
IL
a
O
N =
W
W
ti
SIGN PANEL
SIGN BRACE, WHEN
REQUIRED - SEE
STD. PLAN G-50.10
N �
SIGN POST - 2 112' (IN)
2 SQUARE, 12-GAGE
STEEL TUBE (SEE
w NOTE 3)
FCI
I
W
STABILIZER FIN
— Q
m
io
II
CLEAN -OUT BAR
~
BOLT STOP
FOR SIGN POST
ANCHOR
w
0
LEG ANGLE
LOWER SIGN POST
SUPPORT - 2 1l2" (IN)
COMPACTED NATIVE
BACKFILL MATERIAL
SQUARE, 12-GAGE STEEL TUBE
COMPACTED NATIVE ELEVATION
9°°-jl
DIAM.
12"
DIAM.
BACKFILL MATERIAL
TYPE ST-3 SIGN SUPPORT
ELEVATION
ELEVATION
BURIED POST SIZE
DEPTH
TYPE ST-1 SIGN SUPPORT
TYPE ST-2 SIGN
SUPPORT
z-s^ 2^,21/4^
3'- 0" 2 1 /2"
TOP OF SIGN TOP OF
�� SIGN POST
SIGN PANEL
C
w
BOTTOM
OF SIGN 11,\r-
VIEW OA
SIGN POST
TYPE ST-1
SIGN POST
SIGN
POST
LOWER SIGN
POST SUPPORT
SIGN POST
WEDGE
STABILIZER FIN
HEX BOLT WITH NUT
AND WASHER (TYP.)
ANCHOR
LEG ANGLE
BOLT STOP
FOR SIGN POST
TYPE ST-2
BOTTOM
OF SIGN
FINISHED
GROUND
LINE
' 1B
—III _ -- - - - _- ll_
—III _ _ -_ __
'I 1 II II I I -- - - __ I 0
ITI—--_- - - - -- --
III.
------ - - - - --
r-0'
MINIMUM
1A CONCRETE\ PAVED STREET
GENERAL NOTES:
IA. 3 INCH MINIMUM CLASS B ASPHALT, PER SECTION
2-06,3(2) OF THE 2002 WSDOT STANDARD
SPECIFICATIONS FOR ROADS, BRIDGES AND MUNICIPAL
CONSTRUCTION.
1B. CONCRETE PATCH TO BE THE SAME DEPTH AS EXISTIN(
CONCRETE STREET.
SB 1C. 12 INCHES - COMPACTED DEPTH TOP SOIL TO BE
FINISHED WITH SEED OR SOD. SEED TO BE WEED FREE.
2, SAWCUT
3. ALL JOINTS BETWEEN OLD AND NEW ASPHALT TO BE
SEALED (SECTION 5-05.3(8)B) USING A HOT POURED
JOINT SEALANT, PER SECTION 9-04.20).
4. 6 INCHES - CRUSHED SURFACING, PER SECTION
9-03.(9)3, AND PREPARED PER SECTION 2-06.3(2),
'SUBGRADE FOR SURFACING'.
5(A). GRAVEL BASE MATERIAL, APPROVED WSDOT SPECIFIEI
MATERIAL, OR SPECIFIED IN THE APPROVED PLANS,
MATERIAL TO BE COMPACTED TO 95%, PER SECTION
7-09.3(11) 'COMPACTION BACKFILL'. SEE ALSO,
SECTION 7-08.3(3) 'BACKFILLING'.
50). CONTROL DENSITY FILL WILL BE REQUIRED BY THE
CONTRACTOR IF THE TRENCH CROSSING FAILS.
6, THE PIPE ZONE SHALL BE BACKFILLED WITH SAND
BACKFILL TO 12-INCHES ABOVE THE PIPE, PER
SECTION 7-09.300) 'BACKFILLING TRENCHES'. THE
PIPE ZONE SHALL BE COMPACTED TO 907, PER
SECTION 7-08.3(1)C,
7. SAND BACKFILL - PIPE ZONE
B. 6 INCHES - SAND BACKFILL
9, LAY ALUMINUM LOCATE TAPE A MINIMUM OF 12 INCHES
BELOW FINISHED GRADE AND 12 INCHES ABOVE PIPE.
DETAIL: ST-01
STREET CUT REPAIR
TYPICAL
PPENDIX A - STANDARD DRAWING 2009 i
x
(�
N
w
F
x
J~Z
O
W
a
TOP OF i
LOWER
SQUARE
TUBE
ll �
1N ` w � 1K NYLON WASHER
o �T
io " �B1OLT STOP 7/16" (IN) INSIDE DIAMETER (I.D.)
FOR SIGN POST STEEL FLAT WASHER
3/8" (IN) DIAM.
LOWER SIGN POST 3 1/2" (IN) LONG
SUPPORT - 3" (IN), HEX HEAD BOLT
7-GAGE, HOT -DIP GALV.,
HEAVY-DUTY ANCHOR SIGN PANEL
12COMMERCIAL CONCRETE
DIAM.
ELEVATION
E ST-4 SIGN SUPPORT
SIGN POST
,61
LOWER SIGN _/� F LA NGED SHOULDER BOLT
POST SUPPORT WITH NUT AND WASHERS -
2 REQUIRED (TYP.)
CLEAN OUT
BAR
BOLT STOP
FOR SIGN POST
—3 TYPE ST-4
DETAIL OB
2
v �a V 6
I i
v
r�11'
v
n kF 4 F
O - F
v
O 5
9 v.
v v
� e
DETAIL NOTES:
1, 8 INCH OFFSET FROM CENTER LINE ON SEWER LINES ENTERING THE MANHOLE BASE AT LESS THAN 80 DEGREE .
2, LESS THAN 80 DEGREES TYPICAL.
3, 80' OR MORE TYPICAL,
4. CONCRETE SHELF SHALL HAVE A BROOM FINISH
5. FLOW CHANNELS MUST BE FINISHED SMOOTH
6. PRECAST BASE TYPICAL
7, PVC TO CONCRETE ADAPTOR COLLAR
8. COLLAR SHALL EXTEND INTO THE MAN HOLE NO MORE THAN 3/4 OF AN INCH.
9. ALL COLLARS AND LIFTING HOLES SHALL BE GROUTED INSIDE AND ❑UTSIDE THE MAN HOLES TO STOP INFILTR TION.
SCALE: NOT TO SCALE
DRAWN BY: S.L.
FILE: S-01 FLOW CHANNEL MANHOLE.DWG
EFFECTIVE DATE: REVIEW BY DATE: REVIEWER:
07-20-20C 05-31-2013 BUCKENMEYI
3/8" (IN) HEX
HEAD NUT
7/16" (IN) I.D.
STEEL LOCK
WASHER
SIGN POST
STEEL SIGN SUPPORT
TYPES ST-1 - ST-4
INSTALLATION DETAILS
WSDOT STANDARD PLAN
G-24.50-05
SHEET 1 OF 1 SHEET
08/7/19
DETAIL: S-01
FLOW CHANNEL
TYPICAL
PENDIX A - STANDARD DRAWING 2009
ADDITIONAL STANDARD DETIALS
COA STANDARD WATER DETAIL
PW#19-136-DEV
This plan sheet is accepted for construction in accordance with the
City of Anacortes ordinances and policies. Actual conformance of the
design with applicable laws is the sole responsibility of the
professional engineer, whose name and stamp appear on this sheet.
Acquiring, complying with, and providing mitigation for all Federal,
State, County, and Local Laws, permits, and mandates, including but
not limited to the Endangered Species Act, Federal Wetland Permit,
State Department of Fisheries Hydraulics Permit, Federal Flood Plain
Permits, National Pollutant Discharge Elimination System Permits is
the responsibility of the Developer, Landowner, and their Engineer.
The issuance of this permit shall not be construed as proof of
com li is with applicable laws and permit requi ments.
�� 11.t5.L-
CITY ENGINEER DATE
The acceptance will expire one year from the date
noted above.
D-16-2019 Rev, B, October 16, 2019
O
cc
q
a
�
zo
v
Q�
C\2
�I
wE�
Pq
O
Z
U
f/]
a
W
a>
a
a�
Z
4
CO
fr
-N Cn
C\2
M
�
Co
.
CO
O
4•->
or
M
^T�
�N!
r4-)
f-i
r�
�I
SHEET NO.
C'7
REV.: -
JOB NO: 201E-11
DATE: Oct. 2019
SCALE: Noted
DRAWN: D. HERRIGSTAD
CHECK: D. HERRRIIGSTAD
SHEET! ! OF