Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2021-0809 1314 37th Street (2)
Y4S, • 3 = Cityof Anacortes Invoice/Permit #: BLD-2021-0809 904 6th Street Applied date: 09/28/2021 N:46014114elloor P.O.Box 547 Issue date: 09/28/2021 ,' Anacortes, WA 98221-0547 Expire date: 03/27/2023 . ''�' (360) 293-1901 *IckC-, Job Address: 1314 37TH ST Permit Type: Single Family Interior Only Alteration Permit ANACORTES WA 98221-4245 Project: APN: P121384 Remarks: ADD A SECOND FLOOR DECK TO BACK OF HOME, ALONG WITH STAIRS TO GROUND LEVEL. +++ CONTRACTOR WILL NEED A CITY BUSINESS LICENSE ENDORSEMENT PRIOR TO WORK +++ Always there... Owner: CONNOR J ODONNELL Contractor: DEXPERTS Address: 1314 37TH ST Address: PO BOX 1992 ANACORTES WA 98221-4245 BELLINGHAM WA 98227-1992 Phone: (207) 317-1669 Phone: (360) 305-9260 License #: General Information: Fees: Deck Square Footage 120 Building Permit Fee 251 .25 Building Valuation 15000 Plan Review Fee 163.31 State Building Code Fee Resi 6.50 Total Calculated: 421 .06 Deposits/Receipts: 0.00 Total Due: 421 .06 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read an amin d this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUE BY PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6th Street, Anacortes WA 98821 mot' O.COD n"le: (360)293-1901 4�g E co C,1T Y 0 �A{, w, � Lial Building Permit Application 4, 1891 1 ✓� Tn FIELq�5ec ckL.L INew rarniiy Residences (SFR) Duplexes Additions and Remodels (SFR& Duplex) Accessory Dwelling Units Manufactured Homes Residential decks and retaining walls FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: I S 1'-- Pii' 131V Subdivision/Lot#: Zoning Designation:y Lot area (size): 7 D Lt1 t I R 1 sq.ft. 2. TYPE OF PROJECT ❑ New SFR ❑ New Accessory Dwelling Unit: ec orch( e► /repair) ❑ New Duplex ID Attached to Primary Unit ❑ Interior remodel n Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building ❑ Retaining wall or duplex (new/repair) ❑ Other: Project Summary: ADIN6A, C© fl R DEUk- TO Etstic OF 00111, LL. #IULLa.4DG)e-TGIZiDfc V S Project Valuation: $ PQ—I. CVO 3. PROPERTY OWNER INFORMATION Name: Coto r e_ 4 /III —L+L Phone: Y.) -a ` t b 4 1 Address(Street,City,State,Zip): Email Address: 114 ?r1 S-Tocur y Cr. J. Po6AeJl rActi I. Ca7ii•,L 4. CONTRACTOR INFORMATION Name:* Agivs3 CDMKTe lltLT)014 Phone: ( DL:) Contractor's Business Licenses State License#: City License#: *Ali Contractors&Subcontractors must have a valid City NAPNIC S i 7 JjI1 of Anacortes business license prior to doing work in the Expiration Date: te: Expiration Date: City. i1 0'-e�-- AN Address(Street,City,State,Zip): Erna Address: i L r.70q SotAn4 f ttut V of6 , " - LI Page 3.of19 Res. Building Permit Application Submittal Checklist Updated April 20,2021 Y D PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT ' "{' Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 mod, ' Dh.,'?e: (360) 293-1901 -\ coDE co 47A s`��' G1TY0 , " '1 Ali m.tSON -` yr. ity will contact for anything r , + 1891 <Sr z ❑ Applicant &Property Owner ❑ contractor — �✓, C Cal 6s`o Torreio11.45 Phone: Address(Street,City,State,Zip): Email Address: 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write"no lenders"on the Name Line below. Name: 00 1 ehDr)ciz Phone: Address(Street,City, ,SState,Zip): Email Address: 7. ACKNOWLEDGEMENTS & SIGNATURE • Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean --the application has been deemed technically complete and sufficient for staff review. I understand that if I submit incomplete, inaccurate,and/or erroneous information it will take the lap City longer to process my permits. I understand and acknowledge that I could be responsible for providing as-built drawings(on paper iliii rat iii__ or electronically)as part of the project's certificate of occupancy process. 4_...I understand and acknowledge that Special Inspections could be required as part of my project, and VW if needed I will be required to pay for the cost of these inspections. ,.. I understand and acknowledge that financial securities could be required as part of the work I am mpleting and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. 1i...co I 1_understand that if permits are reviewed concurrently such as design review, site plan,traffic (vim' 'c�oncurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. Res.Building Permit Application Submittal Checklist Updated Aprif 20,2021 Page 2 of 19 Y o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT '{' Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 ` on to Phnne: (360) 293-1901 - � G1T Y O A w�� { Allialk I am either the owner of the property listed on this application or the owner of 4, 1891% t�,, ithorized me to be their representative to act for them. I also declare under ``QCOR� c ,. - nder the laws of the State of Washington that all of the statements and answers ��FrELn-3 nd the information submitted with this application form is in all respects,true, correct, and complete to the best of knowledge and belief. ____C)).--,,, _.....-'---\-----,_ (')/13f(A E16)- Signature Date CcoR. D)0A)"../eLL Printed Name Res. Building Permit Application Submittal Checklist Updated April 20,2021 Page 3 of 19 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 ' -ne: (360)293-1901 �O40R E cpv1/46 I 6 TRUCTURE AND SITE INFORMATION 1891 �✓'VCp �w MEREo� ERE WORK IS OCCURRING A o rret 0 PARCEL � J Nl1MRFR1S1 PI rp�-I v3l"1 (L 1 p- - "1} ) 2. DETAILED PROPOSED STRUCTURE INFORMATION Complete the following information as it relates to your project. Mark items that are not applicable with "NI/a" Structure height: ( 0 par AREA SQUARE FOOTAGE OCCUPANCY GROUP CONSTRUCTION TYPE OCCUPANT LOAD 15t Floor: 2nd Floor: f 0 3rd Floor: Basement: Garage: Total deck: aQ Total porch: Other: Other: Other: 3. QUESTIONS ABOUT THE PROPOSED STRUCTURE is a fire sprinkler system being installed? ❑ YES Nr NO Is a monitored fire alarm being installed? ❑ YES NO Are retaining wall(s) being built? ❑ YES NO Are structural plans required? _ ❑ YES al NO 4. PROJECT SITE INFORMATION A. Is work within the City's right-of-way proposed? If yes,you will be required ❑ YFg � NO to submit a right-of-way permit application. If you have already submitted a ROW permit, list the permit number here: B. Is the property located in a flood zone? ❑ YES Ei NO If yes, list the flood zone designation: C. Are there slopes in excess of 15% on or abutting the site? If yes, a ❑ YES El NO geotechnical report will likely need to be submitted. Res. Building Permit Application Submittal Checklist Updated April 20,2021 Page 8 of 19 , � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT !!� Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6th Street, Anacortes WA 98821 FO% conEco"` ie: (360) 293-1901 _ Illel Allee rn areas or buffers on or abutting (within 300-feet of)the ❑ YES NO y ?s, a critical areas report will likely need to be submitted. 1891 eCt! ,Z S o - l �cr OnRSe�G�` -I 5,000 sq.ft. in area? El 14 NO It yes,your site and building will need to comply with the standards in AMC 19.43.O10.C. F. Is your project involving an accessory dwelling unit? ❑ YES ,g) NO if yes,your site and building will need to comply with the standards in AMC 19,47. G. Will more than 2-acres be cleared and/or more than 5,000 board feet ❑ YES gi NO (about 1 log truck load) of timber be harvested? If so you may need to obtain a forest practices permit from DNR. H. Is this project subject to the SEPA process? If yes,you will be required to ❑ YES NO submit a SEPA checklist. If you have already completed the SEPA process, list the permit number _ here: 5. REQUIRED SIGNATURE 1 hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects,true, correct, and complete to the best of knowledge and belief. aA1)-t,1)-1 Signature Date L___ f1Dr niAe1 - Printed Name Res, Building Permit Application Submittal Checklist Updated April 20,2021 Page 9 of 19 F � "t y D PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT ' Mailing Address: A.O. Box 547, Anacortes, WA 98221 � ` `'�- Office Location: 904 6c6 Street, Anacortes WA 98821 4• +co Eco A le: (360) 293-1901 w" 1TYO c rr. � N ' LUMBING AND MECHANICAL FIXTURES 4, 1891 °FIELD ESQ Equipment Type: Appliance/Equipment Information (new and relocated): Total#: Furnace: Gas if: Elec#: BTU: Other#: Wall Heater: Gas#: Elec#: Other:#: Location(s): L. fi) Gas Water #: Location(s): Heat Pump: Elec#: Other#: Capacity: Air Conditioning: Elec#: Other#: Capacity: Radiant/Hydronic Gas#: Elec If: Other:#: Location(s): Exhaust Fans: Bath#: Laundry#: Other: Range Hood: #: Location(s): _ Y Fireplace: Gas#: Elec#: Other:#: Location(s): Clothes Dryer & Duct: Gas#: Elec#: Other:#: Location(s): Stove/Range/Oven: Gas#: Elec#: Other:#: Location(s): Gas Piping/Outlet(s): #: Location(s): Boiler Gas#: Elec#: BTUs: Location(s): - Other: ,#: Location(s): V TOTAILMECHANICAL OUTLETS, fr) , PLUMBING Fixture Type (new and Total#: Fixture Type(new and relocated): Total#: relocated): ,Water Closet(Toilet): Refrigerator water supply(for water/ice 0---- Kitchen Sink: I _ Pressure Reduction Valve/Pressure Regulator: t -, Utility Sink: Water Service Line: Tub: Water Piping: 1 Hand Sink: Clothes Washer: Shower: Electric Water Heater: Tank-less? Yes ❑ Dishwasher: L Backflow Prevention Assembly: Hose Bib: Other: TOTAL PLUMBING FIXTURES: � '�.°���E. -..'3..�?x��' � " 1 .yxs�i�lu,ai.'x..�F°�i .:�}9'SaF� w�`k_'wtrda'»y.,y .x�, sswi..�:. - ..... Res. Building Permit Application Submittal Checklist Updated April 20,2021 Page 10 of 19 r _ _ Y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT ° 'T oe Mailing Address; A.O. Box 547, Anacortes, WA 98221 "�°" Office Location: 904 6th Street,Anacortes WA 98821 c oco� ie: (360)293-1901 ��,„�C,1T Y O A{� m �G � 1891 AA, . . A RCH!TECTURAL PLAN REQUIREMENTS • ����T�CC1Rse�� !HERE WORK IS OCCURRING rrf_t ADDRESS: 1. j S- cr PARCEL { ) p II I R� (t-cfr 1-NUM6ER SI 1 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete,code compliant architectural plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11" x 17" and drawn in an architectural scale. • Architectural plans for structures 4,000 square feet or larger are required to be prepared and stamped by an architect licensed in the State of Washington. • Structural plans must be stamped by a structural engineer licensed in the state of Washington. 3. REQUIREMENTS FOR ALL ARCHITECTURAL PLANS COMPLETE PAGE#ON REQUIREMENTS a YOUR PLANS Cover(or 1st page) must include: • Site address • Parcel number • Lot number(if applicable) • Lot size • Lot coverage a % impervious surface coverage Floor plans with existing(if applicable) and proposed building layout with square footages and with the use of each room/area labeled. Window and door sizes labeled and window ventilation area. Commercial, Multi-Family, and Mixed-Use Structures must also include door and window schedules. _ WAPlumbing, duct, and electrical layout. Penetration protection must be shown. NIA Opening headers, size, and material. Cross section details, showing typical foundation, floor, wall, ceiling and roof construction and insulation. Structural members labeled as to size and spacing as well as bracing, blocking, bridging, special connectors, and anchor bolts. f' Details documenting energy code compliance. Exterior building elevations demonstrating compliance with applicable structure type design standards (small lot, duplex, or ADU) and maximum building height Res.Building Permit Application Submittal Checklist updated April 20,2021 Page 11 of 19 A F; t'�y Q PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT ,., Mailing Address: P.O. Box 547, Anacortes, WA 98221 t'( ':9a+r , ' Office Location:904 6th Street, Anacortes WA 98821 1 _RCOD� aFo cow le: (360)293-1901 ,w�`�G-0 Y O Ae m- tieight (see AMC 19.42.120 for measurement methods,exceptions and modifications). �4, Is9' 2V e how a line representing,and label the elevations of,the existing natural .. ``QCo -' 6- )pography at the foundation at the front of the building. ��Fn:Lose( or corner lots and lots that slope downhill from the property line at the front 1 of the building: Show a line representing,and label the elevations at the center of all exterior walls of the building. • For ADUs only,include elevations demonstrating compliance with the height/setback plane(see AMC 19.47.030(C)(6)), Special details as needed (i.e., stairs,fireplaces, special construction). N/F) Insulation and insulation values of walls, slab,floors, and roof/ceiling. Allii Existing and proposed grades with slope of lot shown. T; I;° I1 Res.Building Permit Application Submittal Checklist Updated April 20,2021 Page 12 of 19 � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 �'' oeoRcY ego e: (360) 293-1901 fi I G` STORMWATER MANAGEMENT MINIMUM +„ 891 <9COg'5 k, e 5 DETERMINATION T�FIELD 1 _. 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: R i[,1 '1"r� e.�.�.�- PARCEL NUMBER(S) Pr -t 3 J Lor 1-6 2. GENERAL INFORMATION Most development within the City of Anacortes that involves disruption of soils,or construction of buildings, streets, parking lots, etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed(grading,vegetation removal), or the amount of hard surface that is created or replaced on a site(building footprint,concrete,asphalt or gravel parking,sidewalk,etc.) This form is largely targeted for small projects and single family residences. For larger projects and more information please refer to the Anacortes Municipal Code(Chapter 19.76 Stormwater Management)and the latest Washington State Department of Ecology Stormwater Management Manual for Western Washington (Ecology Manual). 3. HARD SURFACE AREA CALCULATION Please calculate your project's hard surface amount;guidance is provided on the next page of this document. Use your project's total hard surface calculation to follow the flow chart(s)in this packet and determine the level of stormwater management required for you project. When determining your permit level or if stormwater thresholds are met or exceeded the entire project must be considered. A project is that portion of a property,properties,or right of way subject to land disturbing activities, new hard surfaces and replaced hard surfaces. The hard surface on your property will determine the storm water utility fees and the stormwater general facility charge. Ali new or replaced hard surfaces should be accounted for. Below are excerpts from the Anacortes Municipal Code and Ecology Manual that may assist you in preparing this information. "Hard surface area"means an impervious surface, a permeable pavement,or a vegetated roof 'impervious surface'means a non-vegetated surface area which either prevents or retards the entry of water into the soil mantle as under natural conditions prior to development. A non-vegetated surface area which causes water to run off the surface in greater quantities or at an increased rate of flow from the flow present under natural conditions prior to development. "Replaced impervious surface"means,for structures, the removal and replacement of impervious surfaces dawn to the foundation. Far other impervious surfaces, the removal down to bare soil or base course and replacement. Res.Building Permit Application Submittal Checklist Updated April 20,2021 Page13of19 p •t� y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT ` A' Mailing Address: P.O. Box 547, Anacortes, WA 98221 i , ►'Ap,1„ Office Location: 904 6rh Street, Anacortes WA 98821 ��QFORconEco e: (360) 293-1901 w 1TY O A t m 7 N,-' y ince 4CORS ° Total 4vFIELDSe� �7r1 (sr) , - l Total Area of Land disturbing activity0 Total area converted from vegetation to lawn or landscaped areas (Z)I Hard surface area calculation NA Existing Removed Proposed Proposed Description (SF) (SF) Replaced New (SF) (SF) Non Pollution Generating Hard Surface Area (Sidewalks,paths, patios,etc.) Pollution Generating Hard Surface Area (Driveways, parking areas,etc.) Total Hard Surface Site Size Existing impervious surface coverage% (sq.ft. hard surface/site size) Use the information in the above table to navigate the flow chart(s) on the next page and determine the applicable stormwater management minimum requirements for your project. Then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Engineering Department Forms website and provide required submittal items/plans. Check applicable box Minimum Requirements Determination 0 Minimum Requirements#1-9. 0 Minimum Requirements #1-5. Res.Building Perr�Application 5ubmil tal Checklist Updated April 20, 21 Minimum Requirement#2. Page-fie f 19 ,z Please have property i. line clearly marked at ` time of footing inspection. 4- is At - y z-s �`8 = s. "0, `'� r \. U, /-1 -4 Q\\ 011 , W V. 4 i- 1 = r- . 4-- 42 f F, •w a sc.� Y�� Y U y�rtCE �o CITY OF A ACORTES z .., 04 s�`� J I28' = PLANNING AND BUILDING DEPT: 0 , fg o :. 0 ° APPROVED PLANS 6cd C' • o f 2 REVIEWED FOR CODE COMPLIANCE g u.3 3 o A� ��` PERMIT#: BLD-2021-0809 0 CI x co 0 IX 0) g ��1� ADDRESS: 1 11 7T� T. j APPROVED BY: / fr N 0 8 i SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT i'CC lb Z I BE ALTERED WITHOUT AUTHORIZA ON. 1ST ttrw\--noklfV\ 1i Less than 4" spacing , � rLLVFcT JDI� Provide 4 DTT1Zs or required. two DTT2Zs at deck to house attachment. PIO( Oar-����i[i - , 04-X-I 0 I ILTL i 17 I .SPALI tL, 13!: A ,, 7_,FL, Li _ /— c: 6 .4 WEL (a C) 137- I i - ___ 4, —► la x ID col srs 12." U 2X8 PT HF #2 wo old be structurally Ida0,5"joidi i-i tp c L-f' fr),S 0 c 1p �„ ip�s adequate in lieu of (c.� e,-o �f l y,� ' 2 2X1 Os. c � or lo'I�-- WO�� �''x ors) Posy 17xt 6x6 --6,, 6' Provide minimum - 1 P" Rcv TF� 2X8 deck ledger, ay - -I Material to be secured to house , ; `,b EP with 1/2" lag bolts at - - pressure treated or 22" OC spacing or �-' naturally decay resistant. equivalent. RD�W� - o r U w 4/, ./1.74 5-& 1 STAIR. bt-i-Al LL focisr 1 i E - --ill., 1111114' I I 1.--- I. If treads are open, Less than 4" spacing they must prevent the required. �c passage of a 4" �o ti s � sphere. o ›. :. Oo o r C.) w �3fi 5�