HomeMy WebLinkAboutPermit File 3116 V Place ANACORTES PLANNING & COMMUNITY DEVELOPMENT DEPT. PERMIT CENTER PH (360)293-1901 ' t. P.O.BOX 547,ANACORTES, WA 98221-0547 FAX (360)293-1938 1891 4 IAN MUNCE,DIRECTOR • EDWIN FRANK,BUILDING OFFICIAL • Email:ed@cityofanacortes.org June 12,2003 Ms.Jana Pisciotta The Donut House 2719 Commercial Avenue Anacortes,WA 98221 RE: Grease Interceptor 3116 V Place Dear Ms.Pisciotta, Thank you for the opportunity to provide advance information regarding your proposed commercial furnishing bakery at 3116 V Place. We hope the following information will help in framing plans for the commercial kitchen. We have discussed with the wastewater treatment plan manager,John Franz,your request for use of a 701b above floor grease trap verse an in ground grease interceptor and offer the following. Based on the information provided an in ground grease interceptor would be necessary. (2000 UPC Section 1014.0) The grease interceptor would need to be sized using Appendix H of the 2000 UPC(copy attached). If you have any questions,please feel free to contact me at 360.293.1901. Thank You, CITY OF ANACORTES Don Measamer Plans Examiner DM:md cc. Bob Hyde John Franz r y BUILDING PERMIT CITY OF ANACORTES PERMIT NO.: BLD1999-00126 P.O. BOX 547 APPLIED: 99-06-22 ANACORTES,WA 98221 ISSUED: 99-06-30 (360)293-1901 EXPIRES: 00-06-30 SITE ADDRESS: 3116 V ASSESSOR'S PARCEL NO.: 350230-2-223-0002 PROJECT DESCRIPTION: Tennant improvement: enclose mechanical area on second floor area per approved plans as noted. OWNER CONTRACTOR WHISPERING WINDS P.O. BOX 1390 DALE GEFFE ANACORTES, WA 98221 2210 21 ST STREET ' ANACORTES, WA 98221 Primary Phone: Primary Phone: Phone 1: 360.299.1485 Phone 1: 360.293.1145 License#: LIC DALEGC"012CJ TYPE OF WORK: ALT AREA VALUE: $ 18000.00 TYPE OF USE: IND LOT: sf REQUIRED SETBACKS: CENSUS CATEGORY: 437 1ST FLR: sf ZONING: ? 2ND FLR: sf FRONT: ft Occupancy Groups BASEMENT: sf SIDE 1: ft GAR/CARPORT: sf SIDE 2: ft 1: F2 2: OTHER: sf REAR: ft 3: 4: REQUIRED PARKING Construction Types NUMBER OF UNITS: TOTAL: 1: 5N 2: STORIES: HANDICAPPED: 3: 4: BUILDING HEIGHT: ft COMPACT: IMPRV SURF: sf FEES NOTES: Type By Date Receipt Amount PLCK EF 99-06-30 10277 $153.56 PRMT EF 99-06-30 10277 $236.25 STBC EF 99-06-30 10277 $4.50 Total: $394.31 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and state and federal laws regulating activities covered by this permit. Issued by Appli nt or Own 1 Signature CONDITIONS OF APPROVAL: 24 Hour Notice Required For All Inspections G\t Y o�, CITY OF ANACORTES COMMUNITY DEVELOPMENT DEPARTMENT /�► " PERMIT CENTER — 904-GTN STREET - d t C t.,: . q ,��, �� Gl�1TE OF ® � C�PA1#I�Y This is to'ce$$that the occupancy listed hereon has been inspected Swill hereby approved,Jor use. 1116 V Place COM98-0177 Address of Building/Premises Building Permit No. Whispering Winds Ocekipent . Suit.No. Gala..e radon No. Whispering Winds 5N F2 B Owner Type of Construction TYM of Occupancy . P.O. Box 1390 Industrial Adb u of Owner Zoning District - Maximum Occupancy Load Square Fat Sttwrom of Restrictions First Floor Second Floor F2 = 15,487 square feet = Occupant Load 77 F2 = 5,900 square feet B = 513 square feet = Occupant Load 5 Occupant Load = t9 Total Occupant Load for First Floor = 82 B:= 1,440 square teet Occupant Loan == 15 CO Total for Second Floor = 44 i Inspection Appxlval: Issued By: i l Fire Marshal / Date . Building meal Date /r U THIS,.CE�1' I.CATE 1 , S PIAY'ED IN. LI, IC AREA R.Yised SBg TO,BE.�O L `iY.TI4E:BUILDING OFFICIAL MECHANICAL PERMIT CITY OF ANACORTES PERMIT NO. : MEC99-0003 P .O. BOX 547 APPLIED: 01/05/99 ANACORTES, WA 98221 ISSUED: 01/05/99 (206) 293-1901 EXPIRES : 01/05/00 SITE ADDRESS : 3116 V ASSESSOR' S PARCEL NO. : 350230-2-223-0002 PROJECT DESCRIPTION: Add mechanical equipment. — OWNER — CONTRACTOR WHISPERING WINDS RONK BROS INC. P.O. BOX 1390 837 E MOORE STREET ANACORTES WA 98221 SEDRO WOOLLEY WA 98284 299-1485 855-1025 RONKB**282N3 TYPE OF WORK. . . :ADD BOILERS/COMPRESSORS- DOMES . INCIN • 0 TYPE OF USE •COM 0-3 HP • 0 COMML. INCIN • 0 3-15 HP • 0 RELOC/REPAIR. . . : 0 FUEL TYPES 15-30 HP • 0 CLOTHES DRYERS . : 0 : /GAS/ / / : 30-50 HP • 0 GAS WTR HEATERS : 0 FURN < 100K BTU: 0 50+ HP • 0 STOVE, APPLI . . . : 0 FURN >=100K BTU: 0 AIR HANDLING UNITS-- FIRE LOG/LITE. . : 0 FURN - FLOOR. . . : 0 <= 10000 cfm. : 4 WOODSTOVES • 0 UNIT HEATERS . . . : 1 > 10000 cfm. : 0 OTHER UNITS • 2 VENT FANS • 1 EVAP COOLERS . . . : 0 GAS OUTLETS • 3 VENT SYSTEMS . . . : 0 HOODS • 0 VENT W/O APPLI . : 0 — FEES — NOTES Code Amount---- By- Date---- Receipt PRMT $ 110 . 05 MD 01/05/99 9583 PLCK $ 99 .00 MD 01/05/99 9583 TOTAL $ 209 . 05 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Issued by Applicant or Owner' s Signature 24 Hour Notice Required For All Inspections mecprmt, Rev: 06/11/92 l ��r Chin 911/1g/'Srfio? �?d�S el .LAG' -�m� 5 S S�'r=�'5�2 2 Spo.9.8 f w .£L� afis�1 /I&LS H le 72k = y W l� rf u,vi S Seu,p7 5� �r�vafOY' �no9Y „SS ;h £ LM� r 1111111111111111111 y g73(hyttriazekii _____, Lficl S. tvlw:Ca,/ to 512n 2 // % %�� ) / / � i � „,�� l,, , � .____ Ansi „ „ ,...5 m Inr 11--- ; 111 arO'�5 "a- -) I LO M I /� r� A, ,ram--a-ri 72- li ono S�'zy 'YJ 057 /1 jfl -cVV/ r n4 tz 4 27yj s s 079 �p�NNN M 9LA/D12//7 G/ vAz y & f/ uric 0/ FaT 5 ?4 6 2?d'7 a- Of}i t iv/piS ' /0/5 //r?? 11/93/1998 21:00 3607559215 FABTECH PAGE 01 .1rT id ft9ak Facsimile Cover She!! t To: c iry'of Kati f.17 Pon— Company: Phone: z43- pro Par i93 - LC From: Randy D. ROCkxrQuOW Company; Fab-Tech 66$ Green Rd. Burlington, We. 98233 Phone; (360) 766-021b Fax: (360) 766-0620 . date: /7- Q y 9y No. Pages: -. 4:42,4et Sr�rates LG ac i� av,,,,ir/ © 2,,-re Tye ,Try Lnr,orns- abettads o'er bou t ro,hy SHE Be raixS' to eo grSe,rS to tads Ltd. rs= en cons c .� mm A-t _I�/ r l e6fireQs ♦n �a iS S i,/°W 6-tie 2.,Mai .?T CZ Srl 15 5'nu g.AJOSentsi40 ;x 4L • /�rlx 'yA ---eit,n � ,,ate (360)7��215 I_ f; tw SG G® � siwwt KiStk ts, Pa; M ° � i y G CeSuGeS �� A • � IEm 6* 6 rip,�I/�T �� SAC� w05,76hfbtO WPM 5 S?i9�r��,r1�� .. 't"• CITY OF ANACORTES BUILDING DEPARTMENT sinirewer .-Ny�ctx FAX COVER SHEET iet P.O. Box 547,Anacortes, WA 98221 Office Phone No.: (360) 293-1901 Fax Number: (360)293-1938 TO: way cKI1/41 F LW Cc, FROM: f d ' ' - PAGES INCLUDING COVER SHEET: Z. COMMENTS: It gispe rew Le)cu0 97ctcaf- S Zar2 *-20vc a-) Jtlov'a . \! U .ffI FD f NHS Facsimile Cover Sheet (3: G fv f of "net &r/L01 07 2t5,C Camps �y: Rho le: 2.43_ fie/ F :x: 2-93 - /9 3,17 Fr• in: Randy D. Rockafellow • Comp• ry: Fab-Tech 958 Green Rd. Burlington, Wa. 98233 Pho we: (380) 755-0215 F !x: (380) 755-0620 Da //ft NO. Pag �T71/1 u i fa u.i/5fcr! la.9fJ win ° 5 14 sir 1)/ 4, �� ;i,a • TO 39Hd HO3lfittd SSZ055L69E 63 : 3 866L1t0/TL r Y , r L. L. co ii '. ems; Us NJ 1p NJ L- 0144144HrHiut , I 'IL. Nettofravar IN) - :cri:"; 1144;111%1- Nklit. ( do y/71ltge Viet , ;1 Call r a0/s 11#r1 Lr0 ! I. 9��g C1 �'3de =d GIs' �d�d m fc"s e?f'%?4D1' _ ` s J$W aC 1 , Xnd6y ^^ ' ji/>Y 76f51si Ok err 0410' alaffi 7;Irs 71" ,ga4ra `zc,,X/ pg see Rae,/ zrvdls 57fla' -F.r SO YJ kr wow al NJ 70'rMilfr 19M? .St' 2/ OJ. 51714 �.,,.. .. p., "4,,jg,t s✓lt,f it 02,11ri>"at "» COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : COM98-0177 P.O. BOX 547 APPLIED: 09/02/98 ANACORTES, WA 98221 ISSUED: 09/08/98 (206) 293-1901 EXPIRES : 09/08/99 SITE ADDRESS : 3116 V ASSESSOR' S PARCEL NO. : 350230-2-223-0002 PROJECT DESCRIPTION: Add 100x100 metal building. — OWNER — CONTRACTOR — LENDER WHISPERING WINDS FISHER & SONS, INC. P.O. BOX 1390 P.O. BOX 534 ANACORTES WA 98221 BURLINGTON WA 98233 299-1485 360-757-4094 FISHES*2500E — FEES TYPE OF WORK -ADD AREA (sf) VALU...$: 550000 Code Amount---- By- Date---- Receipt TYPE OF USE •COM LOT • 5397 REQUIRED SETBACKS---- PICK $ 1423.18 ND 09/08/98 8965 CENSUS CATEGORY -999 1ST FLR • 1600 FRONT • 0 ft PANT $ 2189.50 MD 09/28/98 8965 ZONING 2ND FLR • 700 SIDE(1)..: 0 ft STBC $ 4.50 MD 09/08/98 8965 :LM BASEMENT SIDE(2)..: 0 ft SENA $ 3483.00 MD 09/08/98 8965 OCCUPANCY GROUP GAR/CARPORT...: REAR 0 ft NOT $ 2501.18 ND 09/08/98 8965 :F2 :? :? :7 OTHER REQUIRED PARKING-- NISC $ 3420.00 ND 09/08/98 8965 TYPE OF CONSTRUCTION TOTAL • 0 INSP $ 50.00 MD 09/08/98 8965 :5N :? :? :? NUMBER OF UNITS • ACCESSIBLE.: 0 STRN $ 16785.84 ND 09/08/98 8965 OCCUPANT LOAD STORIES COMPACT • 0 G n�/ .tu Co/o hie 0: 0: 0: 0: BUILDING HEIGHT.: ft IMPRV SURF.: 0 sf (f // qni� FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN -0 G� :? 0-3 HP • 0 COMML. INCIN -0 FURN < 100K BTU: 0 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 29857.20 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 0 FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 0 — NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 0 VENT FANS • 0 AIR HANDLING UNITS-- FIRE LOG/LITE..: 0 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 0 HOODS • 0 WATER CLOSETS...: WASHING MACHINES: FLOOR DRAINS • 0 BATH TUBS ELEC WTR HEATERS: WTR PIPING/TREAT: 0 SHOWERS LAUNDRY TRAYS...: HOSE BIBBS • 0 DISHWASHERS URINALS GREASE TRAPS • 0 LAVATORIES WASTE INTERCEPT.: ADD'L FIXTURES..: 0 KIT SINKS W/DISP: DRINKING FOUNT..: I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. / 1 Issued by 1 ' t or Owne s Sig ure 24 Hour Notice Re fired For All Inspections com_prmt, Rev: 11/04/93 RfE STn TF .4 LLL ` . its 0•-��� ::y2 1 IB99 STATE OF WASHINGTON DEPARTMENT OF ECOLOGY Northwest Regional Office, 3190 - 160th Ave S.E. • Bellevue, Washington 98008-5452 • (206) 649-7000 May 14, 1997 Ms. Lynn M. Christofersen P.O. Box 1390 Anacortes, WA 98221 Dear Ms. Christofersen: I have reviewed the information you have provided on your proposed discharge to the City of Anacortes sanitary system from the windchime manufacturing plant. I understand you have,installed a pretreatment system prior to the discharge to the sanitary sewer. The wastewater from your windchime manufacturing process, after passing through the pretreatment system,would be considered not unlike domestic sewage in both quality and volume. The discharge would contain no toxics that could interfere or upset the City of Anacortes wastewater treatment plant. Based on this, your operation would not require a State Wastewater Discharge Permit from the Department of Ecology. If there are other questions on this please contact me at(206) 649-7046. Sincerely, - Robert Newman Water Quality RN:rn:11 cc: Don Measamer, City of Anacortes 0 2 f-, MTC Materials Testing & Consulting, Inc. Report#F1688 FIELD REPORT Materials Testing&Consulting,Inc. FILE NO. 970202 DATE:3/3/97 1687 Old Highway 99 S. CLIENT: ASI Mount Vernon,WA 98273 Phone: (360)428-0900 PROJECT: Whispering Winds Fax: (360)428-6082 ADDRESS: CITY: Anacortes,WA ENGINEER: Mark Radmaker/G.Goedke CLIENT: ASI ARCHITECT: Michael Tausher ADDRESS: 1751 Cedardale Road CONTRACTOR: ASI Mount Vernon, WA 98273 PERMIT NO: COM96-0249 Time: a.m. Temp: 30-40° Per previous contractor scheduling, we visited project to provide high strength bolt testing and inspection. A prefabricated Garco Building System had been erected and the A-325 bolted connections tightened prior to our visit. Contractor .had used turn-of-the-nut method for tightening and '/" bolts were installed with hardened washers. The 5/8" bolts at end wall and eave overhangs were installed without washers. A Skidmore-Wilhelm calibration device was used to get a calibration for torque arbitration testing on 2 bolts as provided on site. The '/" bolt inspection torque came out to 325 ft.lbs. and the 5/8"bolts were checked using a previously established value of 200 ft.lbs. We checked all the primary H.S. bolted connections to above values. Most were tight and a few were tightened during testing. Connections were marked by MTC. Inspected By: Gary MaComb P-Q-CA-�-' Reviewed By: Niall Hackett DISTRIBUTION: v ORIGINAL: ASI COPIES: City of Anacortes • ALL REPORTS ARE CONSIDERED CONFIDENTIAL AND ARE THE PROPERTY OF THE CLIENT AND MTC REPRODUCTION EXCEPT IN FULL WITHOUT THE WRITTEN CONSENT OF MTC IS STRICTLY FORBIDDEN 1687 Old Hwy 99 South • Mt. Vernon, WA 98273 • (360) 428-0900, FAX 428-6082 814 Lakeway Drive, #161 • Bellingham, WA 98226 • (360) 647-6061 MATE1 AL SAFETY DAriCk SHEET h SECTION 1 - IDENTITY OF MATERIAL ,r • Product Name or Number 4677 Concentrate for Vibratory Finishing Conl1)ollnd Synonyms None Reused 1/9/95 Formula None CAS Number None Chemical Family None Assigned Regulated DOT Proper Shipping Name Buffing Compound Identification Shipping PP g ID Number None EI'A Hazardous Waste ID Number . None This Product DOES NOT: Contain any Class I or Class II OZONE DEPLETING SUBSTANCES(ODS), nor have any ODS been used in the manufacture of any of its constituents. • IIAZAI2QOUS INGREDIENTS • Except for those listed below, each of the ingredients in this product is either 1) not listed as a hazardous chemical in 29 CFR 1910.1200 or, 2) is present in amounts too small to be considered hazardous according to OS1-lA's Hazard Communication Standard. Chemical %/Wt '1 LV-TWA NMOSII No. CAS Number None • SECTION 2 - HAZARD SPECIFICATIONS Known Hazards Under 29CFR 1910.1200 UV Not Determined Hazard YES NO Hazard YES No PEL Not Determined combustible liquid X skin hazard X flammable liquid - X eye hazard X NFPA Hazard Signal rop5oncmatenal X toxic agent X Health • Flammability O ( xplosive material x highly toxic agent X 1 unstable material, x sensitizer X water reactive material x carcinogen X Stability ® Special 1 oxidizer x reproductive toxin X organic peroxide X nervous system toxin X corrosive material x blood toxin x DOT Hazard Class compressed gas x lung toxin X None Assigned irritant x liver toxin X kidney toxin X EPA Hazard Waste Class None Assigned SECTION 3 - SAFE USAGE DATA • Eyes Standard industrial glasses for normal use conditions. Reparatory Protective None for ndrrital use conditions. Equipment , Types Gloves Rubber or poly if work involves direct contact. Other None for normal use conditions. General Mechanical No special consideration for normal use conditions. Ventilation Local Exhaust NA handling&Storage Product will begin to freeze or separate at about+40 F. If frozen, r'recautions thaw slowly and stir before using. Other NA ^` ' 'SECTIO e� - EMERGENCY RESPONSE ATA Exnneuhhine Media Should not burn in as is or use condition. . Special Procedure, NA Fire 1\ Unn,nnl ne,„rd, None are known, p e,INdMeasures Wash off with water. If in the eyes, flush with water for considerable time Exposure until burning or irritation stops, y Steps lobe Taken Collect and save for intended use if possible. If not, flush into chemical Spills sewer or absorb and collect for landfill or incineration: {Va,t.DPpo,ulNtemod Separate and remove abrasive fines generated in the mass finishing process,and then neutralize the pH before entering the biological environment. SECTION 5 - PHYSICAL HAZARD DATA LPL Not determined. (XL Not determined. Fasl It Point Not determined, FLAMMABILITY Product should not burn in as is or use condition. Method Used NA Stable Yes STABILITY w„abie No IIAZARDOUS May Occur No r POLY\1EItiZATION Will Not Occur NO INCOMPATIBILITY Materials to Avoid Alkalis and strong oxidants, , , SECTION 6 - HEALTH HAZARD DATA Istfects of Overexposure Overexposure seems unlikely because this product, even in its concentrated form, has exhibited.no harmful effects to workers through many years of industrial use. However, if a worker with particularly sensitive skin becomes irritated by the product or its dilutions, the worker will have to be isolated from the product or otherwise insulated from contact by means of rubber gloves and other necessary protective clothing. , Emergency treatment ,i Induce vomiting if significant amount is ingested. Contact Physician. SECTION 7 - PHYSICAL and CHEMICAL PROPERTIES Boiling Point - approx.220 F Volatile Organic Components None Vapor Pressure <15 tam Hg Vapor Density(Afro-1) NA 1 Solubility In Water complete p11 4-5 Appearance clear amber aqueous solution Material is: liquid Weight/gallon: 8.8 lb 1 Odor mild fruity odor Evaporation Rate(ethyl acetate=1) <1 • SECTION 8 - MANUFACTURER and SUPPLIER DATA Manufacturer Name RODARMER PRODUCTS,INC. Kenneth W.Rodarmer 9036 West RS Avenue < Schoolcraft,MI49087 Signature � 61,6 668-2052 / e i Dis4ibutur � - e/i •vim(_{`/cd ie"--- title ) President,RODARMER PRODUCTS,INC. Date Form Revised January 9, 1995 ±:✓'r'" :_S, aS i:"µ`.van ',7 ' . : . - �- - _ `i'.,2,'.:-")=:?• i•-" ' - Eeeeen V I4aua'NY Date US.De Ont of labor 'u`-"- ' Material SafeH Data S_beet . �,,,,dw, afm.,a tl.la ae,r.,w.m, .=; m.dn u".w t'oaswerar Ignition sources. +_a. .. _ . MarA lades Crii.M• _ .. • • - =`.;"N:: _••.•,;'n • maws('pManOaye 9ardra gvmw.,6lsr FMm1 .- Y.ea -K _ ` •''Jj•" - - ' . 2S CPR laralSA Seam lust be Fran Apwewd ./ . �'.c�- -.; t• . Aen.W s.*pease reanna ern ..tttaaort. - l ;�k •., mosnemmewwammuo Mated Strong oxidizing agents. • Warr N/raga,dd aM lb. - In a nil w es s".nas aar an,as mma erne ... ACETONE Snare: ,. a ire w k .. . e Wean r, .w pe �w f aw , ap.f awn - Combustio may produce CO, Or rarbe n .vide - _ .�°a'�lt`!�' 'Mtataa l `. -• ^• - _ -'- - • •- ' ' ' • i •r...a Me ooze CMOY.MM.d Alkalis may cause condensation reactions to '-.,':iT: yz'`A M..Mm.waer.- IwaaC r•'v .M'�®, - Jaseo'Chemfeal Corp.• - lF n'REC , - 800-424-9300 My xa ooze r'CL,:�;�_�w:';:t,:-rj.-__a":> T..ww'a rwaw M~lien"- - K- Occur, but the rearrfons are not: exnerr.d rn he vials.? ' -e1.-t.:'-.{....:-_;., .M.---* w41710 swag Streett Ca?1 .. q N,A--rr.:7--: ^x:..:.". • ,.. 1710 Villa -. 615-96$-6005 �- ,�Q�� Pena e aavl-Meets MmND.0 - t:,,-.` �:.•.•:, - - Mountain View G 94042 Cant Amass /� ax..ew E,ay. Minn? aa,T ev.mo.0 .., y:.y 1/27/87: ill"- ' iTan age no ran tnt:C[.;,....“?..:t saran a Avon Ann • ' f.n-1Q • n•ff"....'a.,.ar.w C^"e' Prolonged skin tontact•may cause erchema or dryness, Inhalation ^.4;^^• '� - may produce headaches, fecigue, excitement, bronchial irritation end in it • Section a Mumma Ingredients/Identity Mfomrdon - -•v�' -."•Mean;.Ca m�w'v Meet o�..'ra Inn Oman Hymn) � accn rig a.e."Cia"...w.Lanne .,mownNON amounts narcosis. Serious•-a- Moolsonlnt rare. .,='�`,.::. `:,r _ u'e+w•.em NONEE HT" Mc awPaa•t ova a.ewua'_ Acetone (I-propanone) "1000 • 750 300 - dw"•.w sr ew.ca E•Pwa• Skin and eye irritation, headaches, dizzyness, nausea, Aspiration/ of "'ata� -, .4-”. t,-;,-- --y rn--- -hmS^-, p----"..ia. M.aea ea"c.c+. - _ a ,c4i1gv-e.•.ea Esc.. •Some skin allergies and conditions may be aggravated, , ,- -...- • En9lery ua fN b P16M✓M 'll,tr prod,ie$ eoniains a maximum - Plush akin and eye contact with water for 15 minutes, If inhaled -of 800 grams/liter Volatile Organic Compound. .� n remove victim to fresh-air. Restore breathing if necessary. I£ swallowed DO NOT - • - Section VII-Precautions for Sale Handling and Use - induce vomiting. CALL A PHYSICIAN. v Stews Eke Ts n Ca.WUWw Wx.+e at sax v-.4au,.4eh all 'fririnn annrres Contain material n ... . •- x - ' "- - -- -- and absord with sand or vermiculite. A - -_ - %',Stevan al-phyfinUCheminl Charaetedatin -' - a_ .. - , aa+w M s..as a'+ar mF•n. .. 0.791an.o,.o,n .'w .(all , 133 I 5 w_ " Incinerate or dispose of according to local regulations; 186 . n/a ' '• cm '',.e.W" I laanatol. E..enaen I Pnuur.au I.a.Ta.n a Ha"aHand".e ••w sm Keep away from-heat, sparks and open flames. Avoid breathing n• " 'l sada"..w 2.0 On.m ran.a . Vapot, Avoid contact with skin and eves. 'Cempleta • o'a•'nee...a. Keep container closed when not in use, Store in a cool ventilated area, aw.w.e --veer :,. ▪ - - - - -^- - Water white liquid;-sharp penetrating odor.. Ground eonraiesrs when ffnin. nr Pmm.ine •r"Settler,IV-Flee and Papfoabn Dann,Dan -. _ Section VIII-Central Menam • • • IP "..o.v"a -eK 2.15 YES 13.0 w•w.ov P,e.ee.(SP•ar rMa . . E.wova..q e,.we - • ,v^'"raa _..Ej°"� Preferrable Samos . - Watei'epray, carbon dioxide, dry chemical, alcohol foam. • Swa.Pw Pq..w w M•rn."e.?Gene an tse supplied breathing-air and'protective clothing. resistant I'MP'•n Goggles, - •. - cow Moan..CM.M Of AlAan. . .;:4?3 s; ..:;s'.i -'<„uu+r...M E.ea•.-. -. safety shower a.d air. . - - y-.: - _ , _, Predate vapors may be moved by air currents to distant ignition y,,,xx,w,t P.M,c.. Do not eat, drink or smoke around material, Wash-hands after use, - c'` yj*"t"r- 5caltr, i sources. Vapor-air mixtures are fL®able. ••e.-, ;t-:- % i`°Z.} .•i Menht'.. alms rTP 5rc:eve: ee9.a ... r N. w i•;5.... }-.a ye.w-:•, .:_ .. - - --_ - - _ END OF MSDS • - - - - 0874 - - - - � , rm 9-23-1996 04:25PH Tekcast Industries, Inc. 914 576 0070 P.01 a^ l MATERIAL SAFETY DATA SHEET • PRODUCT IDENTITY: "''LEASE-RELEASE,500 ': (NON CFC 14 OZ . AEROSOL CANS) SECTION I . ' • MANUFACTURER' S NAME: GEORGE MANN & CO . , INC. • FORMULATED PRODUCTS DIVISION ADDRESS: P .O. BOX 9066 PROVIDENCE, RI 02940 EMERGENCY TELEPHONE NUMBER: CHEMTREC 1-800-424--9300 INFORMATION TELEPHONE NUMBER: 401-781-5600 EFFECTIVE DATE: 2/6/90 +• SECTION II. HAZARDOUS INGREDIENTS/IDENTITY INFORMATION OSHA ACGIH OTHER as j COMPONENTS CAS NO. PEL TLV LIMITS 1, 1,1 • Trichloroethane** 71-55-6 350ppm 350ppm 450ste1 70 Dimethylmethane . 74-98-6 1000ppm 1000ppm flam gas 12 utane 106-97-8 800ppm 800ppm flam gas 18 • **Componehtstiarked by an asterisk are present above the De minimus level and 'subject to the reporting requirements of Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40CFR Part • 372 . HAZARD CLASSIFICATION: 0--4 /0=minimum/4=severe Health: 2 Flammability: • 1 Reactivity: 0 SECTION III. PHYSICAL/CHEMICAL CHARACTERISTICS BOILING POINT: N/A SPECIFIC GRAVITY (H2O=1) : > 1 , (heavier) VAPORPRESSURE (mm}g) :Not greater MELTING POINT: N/A , than 90psig at 70'F VAPOR DENSITY(AIR1) : > 1 (heavier) EVAPORATION RATE: > 1 (faster) (Butyl Acetate -1) SOLUBILITY IN WATER: Not > 0 . 07gm (gin/100gm water) )APPEARANCE ,AND ODOR: Water White aerosol spray. Irritating odor at high ' concentrations . Post-it"Fax Note 7671 e91e 14 a To Y70/. \ From P l� '/)I Armo0r W Go./Depf.l �`l l 5. �4. ,NC ]RC...h. c T/;• Phase# .,�/W/�_ 1/g3 Phonepr)I�•.� 09-23-1996 04:26PH ,i"ekcast Industries, Inc. �) 914 576 D370 P.02 tsCTION IV. FIRE & 'EXPLOSION HAZARD DATA • FLASH POINT: (OC) -150'F ' Flammable Limits : LEL: 1.5% combined propellants only UEL: 9. 5% EXTINGUISHING MEDIA: Pertinent to cause of fire only . Product not expected to support combustion. SPECIAL; FIRE FIGHTING PROCEDURES : Self contained breathing apparatus . Cool uninvolved cans to prevent possible bursting. UNUSUAL FIRE and EXPLOSION HAZARDS: Floors may be slippery where wet . Toxic vapors/fumes may be produced from combustion. SECTION V. REACTIVITY DATA STABILITY: Stable CONDITIONS to AVOID: Excessive temperatures that may- .tend to thermally deteriorate the material . ' INCOMPATIBLE MATERIALS: Prolonged contact with or storage in aluminum and its alloys , zinc, beryllium. AZARDOUS DECOMPOSITION PRODUCTS : Hydrogen chloride, hydrogen fluoride, small amounts of chlorine and phosgene gas from thermal decomposition. HAZARDOU5' POLYMERIZATION: Will not occur CONDITIONS to AVOID: None known • SECTION Via, HEALTH HAZARD DATA ROUTES of ENTRY Skin Contadt: XX Inhalation: XX ingestion: Not likely to be ingested in acutely toxic amounts . HEALTH HAZARDS Acute/Chronic: Drying of skin to defatting of skin depending on frequency and length .of contact . Excessive vapor concentrations may induce irregular heartbeats . CARCINOGENICITY NTP : Not found IARC Monographs : Not found OSHA Regulated: Not found ., • I ' 2 r—h CM 09-23-193G 04:26PM Tekcast Industries, Inc. / 914 576 0070 P.03 IECTION Via . HEALTH HAZARD DATA Continued ;IGNS AND SYMPTOMS OF OVEREXPOSURE: Dizziness , giddiness , loss of :o'ordination, drunkenness . Drying of skin to defatting depending on luration and frequency of contact . Vapor concentrations of 10, 000ppm may result in unconsciousness and may be fatal . _ DICAL CONDITIONS GENERALLY AGGRAVATED BY OVEREXPOSURE: May increase nyocardial irritability in people with pre-existing conditions . SECTION VIb. EMERGENCY AND FIRST AID PROCEDURES EYE CONTACT: Wash with large amounts of tempered water . If irritation ievelops or persists , consult physician. SKIN CONTACT: Wash off with mild soap and water'. If irritation develops or persists ; consult physician. , • INHALATION: Remove to fresh air . If breathing has ceased, give • artificial respiration. Seek immediate medical attention. Use oxygen as necessary. The use of epinephrine or other catecholaime drugs should .be considered as a last resort in an immediate life threatening situation. i_ ESTION: Do not induce vomiting . Seek immediate medical attention. { SECTION VII . PRECAUTIONS FOR SAFE HANDLING AND USE STEPS TO, BE, TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Small spilis: mop or wipe up. Remove to out of doors . Large spills : ventilate area. Contain liquid and transfer to steel drums . Cap tightly. WASTE DISPOSAL METHOD: Dispose of in accordance with Federal , State and Local Regulations . PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: Store in a cool, dry area, away from direct sunlight . Do not puncture or incinerate can. OTHER PRECAUTIONS : Read label precautions thoroughly before use. Use only as directed. Avoid spraying on skin or into face or eyes . KEEP FROM REACH , OF CHILDREN. • . 1 09-23-1996 04:27PM Tekcast Industries, Inc. 914 576 0070 P.C4 \CTION! VSIZ . SPECIAL PROTECTION INFORMATION RESPIRATORY PROTECTION: None required in normal use VENTILATION: Use in well ventilated area L6CAL EXHAUST: As necessary to keep vapor concentrations I below TLV' s MECHANICAL: Explosion proof in poorly ventilated, depressed or confined areas where materials readily accumulate and displace air . PROTECTIVE GLOVES : Vinyl where repeated or prolonged contact is expected to occur. EYE PROTECTION: Safety glasses recommended OTHER PROTECTIVE EQUIPMENT: N/A WORK/HYGIENIC PRACTICES : To prevent accidental spraying keep cap in place when not in use . The 'information contained herein is furnished without warranty of any kind. Users are responsible for proper use and disposal of this product and the safety' and health of employees and customers . • • T , \) \ j MATERIAL DATA SAFETY SHEET AB-BRIGHT 1 i SECTION I - IDENTIFICATION MANUFACTURER ' S NAME Manufactured by Nebco Chemical Route 197 Dudley, Ma, 01571 Distributed by Abbott Ball ADDRESS . P .O. Box 330100 Railroad Place , West Hartford, Ct. 06133-0100 EMERGENCY PHONE NUMBER FOR TRANSPORTATION EMERGENCY during normal working hours from 8 : 00am-5 : 00pm EST call 1-508-278-3263 . FOR TRANSPORTATION EMERGENCY during all NON-WORKIN( hours 1-508-391- 5451 or 1-203-520-5524 . At the sound of the beep, dial in your number using touch-tone and we will contact you. If touch-tone is unavailable have operator dial for you. PHONE NUMBER 1-203-236-5901 EFFECTIVE DATE 10-05-90 CHEMICAL NAME AB-BRIGHT TRADE NAME AB-BRIGHT ' DOT SHIPPING NAME COMPOUND , CLEANING , LIQUID, n. o . s . D . O .T . I .D. NUMBER None CHEMICAL FAMILY Cleaning compounds . CHEMICAL COMMENT This product contains no chemical listed.. under Section 313 of Title III of SARA. CAS NUMBER 'No CAS ft . Chemical mixture with no hazardous a materials. CHEMICAL FORMULA Mixture of organic acids and wetting agents. { MOLECULAR UT Does not apply for chemical mixture . SECTION II - HAZARDOUS 'INGREDIENTS HAZARDOUS COMPONENTS HAZARDOUS % TLV (Units ) Nohe 0 . 0% None SECTION III - PHYSICAL DATA BOILING Point(F ) 212° , VOLATILITY/VOL( % ) <83 . 0% MELTING POINT 24°F VAPOR PRESSURE (mm Hg ) Not determined. VAPOR DENSITY (Air-1 ) Not determined SOLUBILITY IN H2O - Complete APPEARANCE/ODOR Red liquid SPECIFIC GRAVITY (H20=1 ) 1 . 17 EVAPORATION RATE Butyl acetate e 1 ; >10 PH 4 . 2 to 4 . 6 of the concentration SECTION IV - FIRE AND EXPLOSION HAZARD DATA 04/09/1991 - i` I \ l ✓ I MATERIAL DATA SAFETY SHEET • AB-BRIGHT ' LASH POINT Non-flammable LOWER FLAME LIMIT Not applicable HIGHER FLAME LIMIT Not applicable EXTINGUISH MEDIA Use extinguishing media for main source of fire , such as dry chemical , foam, carbon dioxide or water. SPECIAL FIRE FIGHTING PROCEDURES. . In case of fire , use water spray, foam, • dry chemical , or CO2 . UNUSUAL FIRE HAZARD None ' • SECTION V - HEALTH HAZARD DATA ROUTES OF ENTRY Ingestion HEALTH HAZARDS NO CARCINOGENICITY NO NTP' ' NO , IARC MONOGRAPHS' g0 ' ' OSHA REGULATED' i NO • THRESHOLD LIMIT VALUE Not established for this product. See SECTION II f; TLV of hazardous materials. OVER EXPOSURE EFFECTS EYE CONTACT : Burns on contact. SKIN CONTACT : Burns on contact. ' INHALATION : Respiratory irritation from breathing of mists and/or vapors . INGESTION : Burns to mudous membranes of the mouth, { throat, and stomach linings . ,+ FIRST AID ' EYE CONTACT : Flush eyes with plenty of water for a least 15 minutes . Get medical attention . SKIN CONTACT : Wash thoroughly with soap and water. INGESTION : Get medical attention immediately! Orin two glasses of water or milk . ,Never give anything • by mouth, unconscious person . DO NOT INDUCE VOMITING! INHALATION : Remove. to fresh air. For breathing ' difficulty, give oxygen or artificial respiration. SECTION VI - REACTIVITY DATA CHEMICAL STABILITY Stable CONDITION$ ' TO AVOID Keep from freezing , INCOMPATIBLE MATERIALS Avoid contact with mild steel , strong alkalies , an oxidizing agents . %DECOMPOS'ITION PRODUCTS At flame temperatures , this will emit carbon monoxide and carbon dioxide fumes from thermal decomposition. 04 /09/1991 -2- (� MATERIAL DATA SAFETY SHEET AB-BRIGHT 1 :,AZARDOUS POLYIIERIZATION . Will riot occur. POLYMERIZATION AVOID Not applicable SECTION VII - SPILL OR LEAK PROCEDURE FOR SPILL In case of spillage, absorb with inert material and flush residue with water down sewer. WASTE DISPOSAL METHOD— . Dispose of in accordance with local, state, and federal regulations . • SECTION VIII - SPECIAL PROTECTION RESPIRATORY PROTECTION Approved respiratory protective equipment must be used when vapor or mist concentrations exceed applicable standards . VENTILATION As needed to keep mist or vapors below the TLV . PROTECTIVE GLOVES • , Rubber gloves resistant to acids. EYE PROTECTION Chemical safety goggles and splash shield. ' OTHER PROTECTION Rubber or plastic apron. SECTION TX - SPECIAL PRECAUTIONS • ABEL SUMMARY HMIS HEALTH, HAZApD 1 FLAMMABILITY 0 REACTIVITY 0 HANDLING AND STORAGE , Keep out of reach from children. Keep container closed when not in use . Keep from freezing. DIRECTIONS FOR USE: FOOT IdOTE5':, • l 04/09/ 1991 -3- _ PAGE OI TRADE NAME: DENATURED ALCOHOL SOLVENT - MATERIAL SAFETY PAGE 2 ' COMPLIES WITH OSHA HAZARD COMMUNICATION STANDARD 29 CFR 1910.1200 ' DATE OF PREP:03/20i66 t - - • - - SECTION 5 FIRE Z EXPLOSION-DATA - - . •�_ 45 \e���SECTION - - _ FLAMMABILI : CLASSIFICATION: FLAMMABBLE LIDUID CLASS IS. • SUNNYS:DE COR ORATIONcc r \I Z FOR FLASH POINT: OD DO. F. TAG. CLOSED CUP - . PENTERPAVE - \' \\}lj INFORMATION: (312)-541-S700 _ ' W-EELCARPENTER NG, ILLINOIS 60070 - LOWER EEXPLOSIVE LIMIT: 4.1% ^c35 DG.C. L.cRGENC, T- ---GNE 3I<^ 54 -5700 SONNYSIDE CORPORATION -_ _ _ " :'000• -9300 ... CHEM TREC EXTINGUISHING MEDIA: WATER SPRAY, DRY CHEMICAL, CO2,FOAM. PRODUCT CLASS; ALCOHOL-MIXTURE MANUFACTURER'S CODE. 834 UNUSUAL FIRE AND EXPLOSION HAZARDS: FLAMMABLE-LIQUID. VAPORS ARE HEAVIER THAT TRADE NAME: NATURED ALCOHOL SOLVENT NPCA HMIS.HI F3 RO• AIR AND MAY TRAVEL CONSIDERABLE DISTANCETO A SOURCE OF IGNITION AND FLASH BACK. - . . nD-uUC7APPEARANCE AND ODOR; CLEAR, COLORLESS LIQUID; CHARACTERISTIC ALCOHOL SPc IAL FIRE FIGHTING rnu:.cuURcS: WEAR SELF-CONTAINED BREATHING APPARATUS F L 1 • AND PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN AND EYES, WATER MAY BE- ' INcrFcLoPeE ODOR. i Ncrrcui:VE FOR P1nc FIGHTING, UB'c.WATER SPRAY TO KEEP FZRE--EXPOSED o CTICN 2 HAZARDOUS INGREDIENTS CONTAINERS COOL. - OCCUPATIONAL - _ _ _ ."_ EXPOSURE LIMITS SECTION 6 HEALTH ' ""D DATA INGREDIENT CAS 4 APPROX. TLV PEL VAPOR PRESSURE • PERCENT . THRESHOLD LIMIT VALUE: SEE SECTION 2. • ^-- --- -- — crrcL:o u REXPGSURE: PROLONGED EXPOSURE TO EXCESSIVE CONCENTRATIONS OF ' ETHANOL - 64-17-O 66% 1000 PFi1 -' :GGO PPM 40 71M HG @55 9G F ETHANOL MAY RESULTIN IRRITATION OF MUCOUS MEMBRANES. 'HEADACHE, DROWSINESS, : METHANOL 67-So-I 4% 200 PPM 200 PPM 96MM HG @68 DG F FATIGUE AND NARCOSIS. METHANOL-IS ALSO NARCOTIC-IN EFFECT AND ITS EFFECTS - - - (SKIN) ARE'CUMULATIVE. OVEREXPOSURE TO METHANOL CAN RESULT IN ACIDOSIS AND VISUAL METHYL ISOBUT SOB-30-i 2% 50 PPM 100 PPM 16..5 MM HG @70 DG F DISTURBANCES WHICH MAY PROGRESS 70 PERMANENT LOSS OF VISION. Y . KETONE'. ROUTES OF EX• POSURE: - ETHYL.ACETATE 141-7SS-6 1% 400 PPM 400` PPM 75 MM HG @20 DG C t ^••• -•A--Crii: MFMAYE HARMFUL IF INHALED. HEPTANE 142-82-5 '"•1X 400 PPM 500 PPM 50 MM HG R25 DO C EYES: LIQUID OR VAPOR MAY CAUSE IRRITATION. -- --SE .. 3 EMERGENCY AND FIRST AID PROCEDURES 'SKIN: MAY B'c'HARMFUL IF, ABSORBED THROUGH .HE SKIN. . - INGESTION: MAY RE.FATAL OR CAUSE BLINDNESS IF-SWALLOWED. , POISON! GET MEDICAL ATTENTION IMMEDIATELY. - _ I 1 .6ECT10N 7 REACTIVITY DATA INHALATION:REMOVE.TOO FRESH AIR.. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION, STAB:LITV:STABLE PREFERABLY MOUTH TO MOUTH. VIP BREATHING IS DIFFICULT, GIVE OXYGEN. • EYES: FLUSH WITH PLENTY' OFWATER FOR AT LEAST 19 MINUTES. GET MEDICAL CONDITIONS TO AVOID: KEEP Awn: FROM HEAT, SPARKS AND FL.AME. d� ATTENTION. ' P _ INCOMPATABIL:Y (MATERIALS TO AVOID): OXIDIZING MATERIALS CAN CAUSE A - KIN: FLUSHWITHPLENTY u WATER FOR AT LEAST 3 MINUTES WHILE REMOVING .IuuRGUS REACTION. CONTAMINAES CLOTHING ANDrSHO S. WASH CLOTHING BEFORE REUSE. GET MEDICAL - HAZARDOUS DECOMPOSITION PRODUCTS: COMBUSTION WILL PRODUCE CARBON DIOX:Gc AND - ATTENTION IF IRRITATION PERSISTS. • - PROBABLY BCARBON MONOXIDE. . - .., -.. IRRITATION INBE>..ON: IF SWALLOWED,- INDUCE VOMITING IMMEDIATELY BY GIVING TWO GLASSES HAZARDOUS POL YMEn.1A..uN;WILL NOT OCCUR. •OF WATER AND IOUS PEG ON..-_.. DOWN THROAT" NEEVER GIVE ANYTHING BY MOUTH __ - _.. ___________—___—__— TO AN-UNCONSC:OUSnPEERSON.BcGET IMMEDIATE MEDICAL ATTENTION. SECTION o FILL OR LEAK PROCEDURES STEPSTAKENRELEASED: "_�':.' ---BEL:..,N 4 PHYSICAL '"-" TO SE IN CASE MATERIAL IS SPILLED OR ^nBE'cCOLLD: - -- -------�--- DA'"' ELIMINATE ALL :GNI IGNITION SOURCES. SMALL SPILLSMAY. BE COLLECTED WITH ABSORBENT THE-FOLLOWING DATA REPRESENT APPROXIMATE OR Tip1CA� VALU-cS. THEY DO NOT MATERIALS. FOR LARGE SPILLS FLUSH AREA WITH WATER SPRAY, PREVENT RUN OFF PRO' .. CONSTITUTE PRODUCT TONS. ENTERING DRAINS, SEWERS OR STREAMS.- - "`.:,, R. PET• _ _ HASTE DIS .:SAL METHOD:INCINERA E-UNDER SAFE CONDITIONS OBSERVE ALL FEDERAL. • ,BOILING RANG-E: ' OG.F: P.i VAPOR DENSITY:HEAVIER THAN AIR. - STATE AND LOCALLAWO•CONCERN:NG HEALTH AND ENVIRONMENT. - - RA �SLOW-ER'THANBETHEER % .uLATILE BY VOLUME:100% - - - - - - _ • - WEEIGHT-EVAPORATION FER.�GALLON:6.7S LBS. - - - - - - - SOLUB/LITY IN NITER: COMPLETE - _ _ - 1472 - _ - - CONTINUES ON PAGE 3 - CGNTiNUEu- ON PAGE - - - H. �\ • BADE NAME)_ DENATURED ALCOHOL SOLVENT PAGE 3 . SECTION 9 SAFE HANDLING AND USE INFORMATION RESPIRATORY PRO,c..,.C$: AN APPnurnIATEE NIOSH-APPROVED RESPIRATOR FOR ORGANIC ' ' , ;:“.'-.-•`VAPOR SnCULD SE WORN-IF Nccuc... q•'.li VENTILATION: RECOMMEND AT LEAST TEN AIR CHANGES PER HOUR FOR GOOD GENERAL - ROOM VENTILATION. , ,r;; . PROTECTIVEGLOVEES: 'S T RESISTANT PROTECTIVE GLOVES. " ;:'".':T EYE PROTECTION: SAFETY GinSoco oHOULD BE WORN IN ANY INDUSTRIAL OPERATION. I ' , f H-,::e OTncn rn.a=. ,IVE'EDUIFi NT: SAFFETY'SHOWERR. EYE WASH, AND WASHING FACILITIES , SHOULD BE:AVAILABLE. - • ---------------------SECTION 10 SPECIAL PRECAUTIONS _ " DEPT. OF'LnSOR STORAGE CATEGCSY: FLAMMABLE LIQUID CLASS IS, ✓% 'YGIENIC PRACTICESt KEEP AwA/ FROM HEAT, SPARKS AND OPEN FLAME. KEEP CONTAIN- _ - . . '�\....-.RS CLOSED WHEN NOT IN USE: AVOID EYE CONTACT. AVOID PROLONGED OR REPEATED I CONTACT WITH SKIN. WASH SKIN WITH SOAP AND WATER AFTER CONTACT. - ✓ . ADDITIONAL PREECAUTIONS1 GROUND CONTAINERS WHEN TRANSFERRING LIQUID TO PRE- , VENT STATIC ACCUMULATION AND'DISCHARRGE. ' 'EMPTY' CONTAINER WARNING,'EMPTY" CONTAINERS RETAIN RESIDUE (LIQUID AND/OR , VAPOR) AND CAN BE DANGEROUS. DO NOT PRESSURIZE, CUT, WELD. BRAZE, SOLDER, . DRILL. GRIND OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS OR OTHER ' SOURCES OF IGNITION; THEY MAY EXPLODE AND CAUSE INJURY OR DEATH. DO NOT - ATTEMPT.TO.CLEAN SINCE RESIDUE IS DIFFICULT TO REMOVE. "EMPTY" DRUMS SHOULD 'COMPLETELY DRAINED, PROPERLY BUNGED AND PROMPTLY RETURNED TO SUPPLIER OR DISPOSED OF IN AN ENVIRONMENTALLY SAFE MANNER AND IN ACCORDANCE WITH GOVERNMENTAL REGULATIONS. - - (LAST PAGE: •• - " T. 1 1 - • , 1472-2 - - - -. " • O C 0-1/01/1994 12:06 4016216279 THE COI ITEl1TLO0 PAGE 01 ..e"....1. ) 02/74/91 THE CONTENT' COMPANY PAGE'I 123 STEWAR'T STREET Q. PROVIDENCE,RI 02903 C7` S 401-421-4040/FAX 401-621-8279 , • ` PRODUCT a VERTAL. 92• -alp ) ,:iffifli: : hIm I s c r SECTION 1 : MANUFACTURER INFORMATION • •--- --ia s....a 53::5 , I a. , CNN* MERW$CY NMA'AOER 1st (21 HOURS) HITS0010O H • 0 F - 0 R - 0 PPE • E C.I.Sal 11801-96-6 ttaa (XRIi'11EAilOR NMR1S CLASS D, DIVISION II, SUBDIVISION (B); CPR 55 0111 RARE TALC mil iSits MN MOMS AS ABOVE SOAPSTONE, STEAIITE NYOAOUS MAGNESIUM SILICATE US ' tI 3$I0.IS4D)2,(N)t0 NOT AMIABLE • .. ,.T MUTES NA'> COSMETICS, PNARMACEUTTCALS PAPER, RLNIBER, INE PAINTS 4110 PLASTICS ::22t4:isziiatiaassa$5Msituss tsfsajniiifiatiltutatisazn{SS:::51zia5 a5 afun Ilia; siiii 3^ SECTION 2 : HAZARDOUS INGREDIENTS 222CT:22ai35:Ipat4IPtianflff3n ::::Sit i•iittt fist:; 2itit:22::..i;•.. EHATA00084%TITliOIENTS - 1 1 1 , . :C,A.S. A :LD/50, ROUTE, SPECIE:LC/SO, ROUTE, SPECIE: .::22 2222.2::2•2.tz 2Iati::5 It 21ti4i::z5::: I ETAIC $5 60 E14007-96-6 :NOT AVAILABLE NOT AVAILABLE i j. EMA6NESITF 30-60 :SA6-93-0 :NOT AVAILABLE NOT AVAILABLE 1 , :CHLORITE is, 1• $ 11318-$9-8 :NOT AVAILABLE ,NOT AVAILABLE , AW1FTfa ROTE$• NO A00ITIONAL NOTES PERTINENT TO THIS SECTION. aii it s ;a tat ii SECTION 3 : PHYSICAL DATA 2:2i 1,212221124221 22222::::if;:t2:222...Rft v Lit t a ' PNYSICAL;ITATE PONDER 1 . DOOR/MINCE A FINE .NITS PONDER SLIDPERY TEXTURE. pee n��N,� i j" EARTHY DOOR Post-It'Fax Note 7671 j MS ODOR TMAES14610 Type) HDT ADDI)CABIE To r�MQ Flom /, 5 I ` VAPOR PRESSURE (SS Ng) NOT APPLICABLE C o co. defy { VAPOR DEN6ITY (AIRfI) NOT APPLICABLE if ABLF Piwtle a T VOLATILE: Phone l BY VOLUME SLIGHT MOISTURE Fax° fnf) 90 2 i'2 Fax# , �`) THE CO ITEi I I PAGE 02 ' 01/01/1994 12:06 4016216'�rj CO. 02/24l91 THE CONTENT! COMPANY PAGE:2 123 STEWART STREET PROVIDENCE,F0 02903 401-421-4040/PAX 401.62140279 i PRODUCT : VERTAL 92 ,' 8Y N(IMT SLIGHT MOISTURE ' EVAPIEOBION Rill (11134C21) NOT APPLICABLE SOIL'S POINT C$ 4.C) NOT APPLICABLE FREEIINS POINT (WI.C) NOT APPLICABLE MELTIN0 POINT (1Ea.C) NOF APPLICABLE OH (SY SLURRY); 9.5 SPECiI1C SANITY 2 7 • 21 SOLU1itZTT IN &*TU (20 C) NEGLIGIBLE .. COBITIBIlla IATES/OIL OTST NOT APPLICABLE , II r :zzztiszflh/iiriirllti ass R:s:a[t i SECTION 4 : FIRE & EXPLOSION . :::arrs:::::[rirsIIrgiitrztirit:::zitra::Rtszxtt i t itf:::sir:z is :r s • .; Navin 041181R ' Ill , . FLAAA11 t1TY..1 NO . 1T YEi SUN Iilte NOT APPLICABLE CONDI 7 NEANS (ITINCI;SN NONE REWIRED SPECIA410000:6 1000 NOT APPLICABLE FLAW (C), NEHIDD NO1 APPLICABLE • AUTO Ii0IE184 TrEUATIpE NOT AVAILABLE MHOS UIFiITTON UHAIS CLASS 0 (POISONOUS AND INFECTIOUS MATERIALS), DIVISION II (OThER TOXIC EFFECTS), SUBDIVISION (6); CPR 55 0411, , iON UNiT NOT APPLICABLE LINS „ • I*t4$11 NOT APPLICABLE ' ' tor , .4iittrio PN01YCiS..: NOT APPLICABLE , ‘ iVIIT TO STATIC NO NOT AVAILABLE:e •y,c-YT' NDT AVAILABLE I 1ST AVAILABLE •• grtfitlA ::t:::itsizitttirrzr,ti::::t13:a:Y.r sir sxz::::axis SECTIONS : REACTIVITY DATA RtsZtzIIrtri::ttrtZA{ttirNitititttttiiirtttttritllit:tsiiz::i[ir::srszzzti.....i[r as is it at tar.....:vs CNEN1CACOTAIIUTY YES 21lNCN;�1181SP NOT APPLICABLE HATAA0 IKYNIOSTION NO tilli SNKCN'C$NIITIONSY NOT APPLICABLE CONPATI ItIT VI N ITNER YES SU85TAM8 :;' 4 N1,;tt 1CN Set NOT APPLICABLE REACTIVIT}, IAIOEI SMAi NOT APPLICABLE 1 CONDIii J HAI Ti OF NOT APPLICABLE I DECONPOSIli1N fS i[ . ' t 41l4111994 12:4F 44152;-_•?79 THE GOiITEI!TI`_J PAGE 03 • 02/24/94 THE CONTENTI COMPANY DAGE:J 123 STEWART STREET PROVIDENCE,RI 02003 401- 21-404GfPAX401.821-8279 •. > PRODUCT : VERTAL 92 SSSSSSSSSS SUITS SSSSSSSSSSS t I SECTION 6 : TOXICOLOGICAL PROPERTIES tt,..z.SSSSS SSSSO 22 Stilt SSttthS i2S ROUTE Of ENTRY: $XUN CONTACT NO ADVERSE EFFECTS ARE KNOWN AS A CONSEQUENCE OF APP',ICA1ION TO UNBROKEN SKIN. MIN 110N NO • ,. EYE CONTACT AS WITH MOST DUSTS OR PARTICULATE MATERIALS, THIS PRODUCT CAN CAUSE TEMPORARY DISCOMFORT AND IRRITATION IF ACCIDENTALLY INTRODUCED INTO THE EYE. , INHALATION, ACUTE PRIMARY ROUTE OF ENTRY. ' 'SYMPTOMS OF ACUTE ACCIDENTAL EXPOSURE WOULD SE NON-SPECIFIC AND SiMiLAR TO 14 INHALATION OF ANY OUST. SUCH SYMPiONS MIGHT iNCLUCE COUGHING, ' WHEEIING, DIFFICULT BREATHINS, AND UPPER RESPIRATORY TRACT IRRITATION. iNNALATiON, CANONIC THE AMERICAN HYGIENE ASSOCIATION SUGGESTS THAI PERIODIC PHYSICAL ) EXAMINATIONS SE GIVEN 10 THOSE EMPLOYEES WHO MAY SE EXPOSED TO HIGH TALC OUST CONCENTRATIONS OR AVERAGE CONCENTRATIONS THAT APPROACH THE TWA. THERE ART INDICATIONS THAT A RELATIVELY MiLD PNEUMOCONIOSIS CAN DEVELOP . OVER 10 - 40 YEARS OF OCCUPATIONAL EXPOSURE TO MIXED DUSTS CONTAINING TALC. SNOXING AND CONCOMITANT DISEASE MIGHT IMPOSE AN ADDITIONAL PULMONARY BURDEN WHICH MAY ALTER THE COURSE OF THE PNEUMOCONIOSIS, TMERE ARE NO SPECIFIC ANTIDOTES TO ACUTE OVEREXPOSURE. • • ' TREATMENT SHOULD 8E OIRECTEO AT THE CONTROL OF THE SYMPTOMS AND CLiNiCAL. CONDITION. INDIVIDUALS WiTH ACTIVE PULMONARY DISEASE SHOULD,kOT SE ASSIGNED 10 A WAVY DUST ENVIRONMENT. REFER TO SECTION X FOR ADDITIONAL INFORMATION. TION NO ADVERSE EFFECTS EXPECTED. EFfE ACRP• "'`• -H: SEE ABOVE, IIIOiVIOUAL ROUTES OF ENTRY. SEE MOVE, INHALATION CHRONIC, 41 .•...` 11017 ,L MATERIAL MASHESITET ACGIH TLV. RESPIRABLE DUST TWA-8 HOUR SHIFT/40 HR WEEK 10 MS/CU.M. ,OSHA PEL TOTAL DUST TVA- 8 HR SHIFT/tOHR WORK WEEK. CHLORITE - ACGIH TLV 10 Mg/CU.M RESPIRABLE DUST TVA FOR 8 HOUR SHIFT/40 . . HOUR WEEK. OSHA PEL S Mg/Cu•M TOTAL DUST TWA FOR 8 HOUR SNIFI/I0 HOUR . MEEK. TALC • AC51H; TLV RESPIRATORY DUST 2 Mg/Cu.M TWA BASED ON 8 HOUR SHIFT, 40 , .f HOUR WEEK. OSHA PEL 20 APACE TOTAL DUST TWA BASED 8 HOUR SHIFT, 40 HOUR 1 WEEK, TORINO Ualli tAl NOT AVAILABLE SEMIS 00001IITY Of NOT AVAILABLE NAiERIAk' CARCENOERitCITV CO MATERIAL NOT LISTED OR REGULATED ASA CARCINOGEN ACCORDING TO NIP, ;ARC AND OSHA ROUTE Of ENTRY ' • NOT AVAILABLE 1 SYNEROIS'tiC ACYCO1M$ NOT AVAILABLE 4 1 j O1/Q111991 12:06 4FJ1521 ) THE COIITEHTI CC) PAGE 04 } • 02/24ta THE CONTENTI COMPANY PA6E:4 7 123 STEWART MEET PROVIDENCE,RI 02903 1.) 401 d21-4040/FAX 401 821-82 79 PRODUCT : VENIAL. 92 . :Xi, ttttNt triritttttittrt ,isa ,t SECTION 7 : PREVENTATIVE MEASURES tilt eartsittitttarIr.ri:::.::::t:ttis ,,, : , PROTECTIVE (BOTANIST SLOWS/ SIPE GENERALLY NOT REQUIRED, RECOMMENDED FOR WORKERS WHO SUFFER FROM DERMATITTS OR ARE SUSCEPTIBLE TO IRRITATION AND DRY SKIN. R1:SPIRATOIEY/TYPE AVOID PROLONGED OR REPEATED INHALATION OF OUST. I. USE A NIOSM APPROVED RESPIRATOR AS REQUIRED TO PREVENT OVEREXPOSURE. ETEKtYPE SAFETY GLASSES ARE THE MINIMUM EYE PROTECTION. , GOGGLES SHOULD BE WORN WHEN WORKING IN AREAS OF POTENTTAeLY HIGH DUST CONCENTRATIONS. - j MISIM TYPE YEAR APPROPRIATE FOOTWEAR FOR WORKSITE. COWNS/1M WEAR APPROPRIATE CLOTHING FOR WORKSITE. p14R(TYPE EYE WASH FACILITY SHOULD 8E IN CLOSE PROXIMITY. EMBINEENINM CINTROLS IF CURRENT VENTILATION PRACTICES ARE NOT ADEQUATE IN MAINTAINING AIRBORNE 4, - CONCENTRATIONS OF PRODUCT BELOW THE 11V, ADDITIONAL VENTILATION CR LOCAL EXHAUST SYSTEMS MAY 8E REQUIRED. PROTECTIVE EOMIPRENT IF CLEAN AND DRY, VACUUM, OR SWEEP UP ARO•RETURN TO CONTAINER FOR USE. LE*.'VILL OTHERWISE, SWEEP CR VACUUM UP FOR DISPOSAL. CAUTION : THE USE DF WATER MASHDOWN IS NOT RECOMMENDED UNLESS THE SPILLED MATERIAL IS ALREADY WET. MET MATERIAL ON A WALKING SURFACE WILL BE EXTREMELY SLIPPERY. WET SPILLS SHOULD 8E THOROUGHLY FLUSHED WITH WATER UNTIL NON SLIPPERY. WASTE SISPOSAL, RETNW MI DISPOSE OF IN ACCORDANCE WITH FEDERAL, PROVINCIAL AND LOCAL REGULATIONS. • EONIFOMT THIS IATERIAL IS NOT A HAZARDOUS WASTE BY RCRA CRITERIA (40 CFR 261). DISPOSE OF WASTE BY BURIAL. WET MATERIAL CAN Si SEVERED IF DILUTED ENOUGH THAT HIGH VISCOSITY OR GEES WELL NOT CAUSE A BLOCKAGE. HAWES EIMICEPAIES AO SURFACES SUBJECT TO SPILLS OR OUSTING WITH THIS PRODUCT CAN BECOME ' ERUIPT EXTREMELY SLIPPERY. KEEP ALL FLOORS, WORKSTATIONS, STAIRS AND HANDRAILS CLEAN AL* DRY. STDRARIONI@S RESPIRABLE OusT LEVELS SHOULD 8E MONITORED ON A REGULARLY SCHEDULED BASIS. ' ' SPECTRA PIPPINS IMSTRUCTIONS 007 : NOT REGULATED 4 i100itiittt4*t :12:::Mr z.r:::::,Gar I taxi ; GG:: , ' SECTION 8 : FIRST AID MEASURES Hi :iti in tit in; aZ I ,' EYE CONTACT FLUSH WITH PLENTY OF LOW PRESSURE WATER FOR FIFTEEN MINUTES, OCCASIONALLY 11FTIN6 EYE LIDS. IF IRRITATION OR REDNESS DEVELOPS, SEEK MEDICAL ATTENTION, SKIN CONTACT USUALLY NO GENERAL CONCERN, ,I BROKEN SKIN CAN BE CLEANSED WITH MILD SOAP AND WATER. . IF IRRITATION OR REDNESS PERSISTS, CONSULT A PHYSICIAN. ' IKHALATIOM PRIMARY ROUTE OF ENTRY. IF IRRITATION OF NOSE OR THROAT DEVLOPS, MOVE AWAY FROM THE SOURCE OF EXPOSURE AND INTO FRESH AIR. . IF IRRITATION PERSISTS, SEEK MEDICAL ATTENTION. IF A VICTIM IS NOT BREATHING CR BREATHING DIFFICULTIES DEVELOP, ARTIFICTA. ,;1 RESPIRATION OR OXYGEN SHOULD BE ADMINISTERED BY QUALIFIED PERSONNEL. .y 01/01/1994 12: 05 401E216— ? THE C'OIITEIITI Cf_r -' PAGE 05 • 02/24/9/ THE COMM', COMPANY PAGE:S 128 STEWART STREET PROVIDENCE.RI 02903 401-421.4040/PAX 401-021.0279 PRODUCT : VERTAL 92 , CALL A PHYSICIAN. ttit IIUST1114 NO TREATMENT NECESSARY. • SPECIE INSTARAMOPIS MO SPECIAL PROCEDURES. iii zznSsStnIZ4z44ttttt:::.s.::::[hits Si 2 SECTION 9 : PREPARATION DATE OF M .5 .0 .5 . li 't:::i:ii iictiosi:apiwicaisiiiiiisiis:i::i: t :iiii DISCLAIMER THE INFORMATION CONTAINED HEREIN iS BASED ON DATA AVATLAOLE TO US AND iS ' ;. RELIEVED ID BE CORRECT. HOUEVER, 'FRANK E. DEMPSEY 4 SONS LIMITED' MAKES MO WARRANTY, EXPRESSED OR IMPLIED RE6AROIN5 THE ACCURACY OR COMPLETENESS OF THIS INFORMATION OR THE RESULTS 10 BE OBTAINED FROM THE4USEAIHEREOF, Y sz ::z:iiwsznn:::c:zics[tisi ' SECTION 10 : ADDITIONAL INFORMATION - itsits S t14 zttttititliss:z::zisiissz::::zi ii"t 1..21 i III ADOITEOMAL LITERATURE THiS PRODUCT IS NATURALLY OCCURiNG AND AS SUCH IS PRESUMED TO BE ON THE OSL. • SOURCES USED IN THE PREPARATION OF THiS MSOS INCLUDE : THE AMERICAN INUSTRiAL HYGIENIC GUIDE SERIES ON TALC. THE AMERICAN CONFERENCE OF SOVEAMMENTAL INDUSTRIAL HYSiENiSiS TLV AND BIOLOGICAL EXPOSURE INDICIES {I FOR 218/-2918: SAX' DANGEROUS PROPERTIES OF iNOURSTIAL MATERIALS. MIS PRODUCT IS ON THE TSCA CHEMICAL SUBSTANCE INVENTORY. THIS PRODUCT DOES NOT CONTAIN QUANTIFIABLE CONCENTRATIONS OF ASBESTOS, ABSESTIFORN OR NON•ASBESTIFORM iREMOLITE, ACTINOLITE, ANiHOPYLLITE, OR NO SUSPECTED CARCINOGENS, (LESS THAN O.IY 8Y VEIGHi) DRE11A t 1. N SOYD MOORE OATEp =k'sv ra2419A • • • • 4t. , ^ IMPERIAL SAFETY DATA SHUT mums sot (—) RCO)WANY S SIFICATION i..�w, rodeo t name 2ItIt4e so Material type Water miocible cutting and grinding fluid concentrate classification/synonye(s) Chemical emulsion/Soluble oil Product use Coolant and lubricant in metal romoval .processes Uanufaeturer address MASTER CHEMICAL CORPORATION 501 West Boundary . perryaburg, OH 43551-1263 Emergency telephone 419-874-1902 Pax number 419-874-0684 ' at, cou?OSITIaIitliTO g{ATIoN ON 1N4*EDISHT4 ... OTHER COMPONENT ONEA ACORN LIMITS PER. 3 Tin 3 RECOH,. • CAS Q %R petroleum oil 5mg/m (mist) 5mg/m (mist) Clone . 8002-05-9 ' S0-8t ' petroleum sulfonate none none none 61789-85-3 204.30, chlorinated alkene polymer none none none 68410-99-1 20-3U nonionic surfactant none none none 68991-48-0 1-10 aromatic alcohol none none none 68603-15-6 1-10, ropylene glycol ether none none none 68603-15-6 1-10 , The exact chemical identities end percentages of the raw materials used in TRIMS SOL are trade eectets. This information is being withheld as provided for in the occupational Safety' and Health Administration's Hazard Communication Rule (29 CPR 1910,1200) . cj 3. nanny 20ENTIPICATEOti Easrgsncy overview Dark green liquid No immediate hazard 1 ' Fire may produce Co, CO2, HC1, SO2 ' ' POTENTIAL HEALTH orrscrB : ,Aouto effects of Eye contest Transient irritation Otnrexposure Skin Contact . possible defatting, nonirritant, nonsensititor Inhalation Nontoxic Ingestion Nontoxic Skin Absorption Nontoxic Gon'o Chronic s'usaata of None currently known V O. E illg�9 OM' '�° 252Th vahY(2.04g3 %p „sac, 0 " '/`', Page 1 of 5 (TRIMS Sol) N�A�1®001 A2 Product/Ingredients listed as NTP Annual Report No, :ARC Monographs No carcinogen or potential carcinogen? OSHA No • ' Signs end symptoms None of exposure Medical conditions None known generally aggravated by exposure 4. FIRST AID MEASURES Emergency and first aid Eyes Flush immediately with cool, clean water for procedures at least 15 minutes Skin Wash with mild soap and warm water Inhalation Remove to fresh air Ingestion If large quantities are ingested, contact a physician v. I In every case pet medical attention as required 5, FIRE F;ODTINO i sun i • Flash point (test method) 305° F (152° C) (COC) None (TCC) flammable limits Not determined Y Extinguishing media As appropriate for the surrounding fire: water (flood with water) , dry chemical, Co2 or "alcohol" foam 1 Special fire fighting None Unusual fire and explosion None procedures hazards 6. ' 11CCIDSNTAL RZLEASSURES Steps to be taken if Mop up or use dry absorbent material is released or spilled • 7 tANNLIMOAND STOWH ', Precautions to be taken I Avoid contact with eyes. Avoid prolonged or repeated in handling and storing skin Contact with the concentrate. Wash thoroughly after handling. Do not swallow. Other precautions Refer to Data and Information Sheet or container labels. Page 2 of 5 (TRIM® SOL) • ,i�.,# , Nw;� ;.., 'sr"� t PROTkmOH Respiratory protection None (Specify typo) - ti entiletion Local exhaust Not normally required Mechanical (general) General room ventilation should be sufficient Special • Nona Other None • Protective gloves None • Other protective equipment None Syo protection Safety glasses Exposure Limits None established by ACGIN or OSHA for product as whole Pilfer to Section 2 9. PZilOICAL AND C8VIICAL PROPERTI$s i Appearance Dark green viscous liquid Odor Mild pleasant odor pE of concentrate Not applicable pit of freshly sized emulsion with dsnineralissd water at 5% 9.1 Vapor pressure (psi) <1 /"\Vapor density (Air■1) Not determined )ilibg point (at 760 na fig) , 217°P (103°C) \-rree:iag point Not applicable ' Solubility in water 100% Specific 'gravity (H2 0=1) 0.99 Percent volatile by 18.48% Evaporation rats (butyl acetate=1) 1 10. STABILITY An AN.STfvITY Stability Stable conditions to avoid None incompatibility Strong oxidisers, acids and alkalis (natoriala to avoid) Aasardous 'coabustion or Thermal decomposition (fire) may produce CO, CO2, decomposition products so Uasardous,polyaarisation wi?l not occur Conditions to avoid None Pago 3 of 5 (TRIM. SOL) • f % I4,,, TOXICQ OICAT. INFOR')QN k 1 . Results • Study - Test Animal Concentrate 10% Solution ) ---Acute inhalation Rat % nontoxic ) toxicity LC50>225m9/1 • Acute oral Rat nontoxic nontoxic toxicity LD50>5g/kg ' Abuto dermal Rabbit nontoxic nontoxic . toxicity LD50>2g/kg •• Primary skin Rabbit irritant • nonirritant irritation PDI index-6.75 PDI index-0.00 Primary eye Rabbit irritant nonirritant irritation Repeated insult Human --- possible- defatting patch Volunteers nonirritant a- nonsensitizer 1�- SCOLOOICAL INFORMATION ' --- No data available $ DIS$OSAL CONSIDERATIONS V,• Waste disposal method Must comply with local, state and' federal regulations. If pre-treatment is needed, chemical treatment or ultrafiltration may • be used. contact Master Chemical Tech Line (1-800-537-3365) for assistance. 14. TRANSPORT ‘NFORMATIQH Department of ' DOT Hazard Classy None Transportation TRIMS SOL is not classified as a hazardous material by DOT. try. AZIOULATORY INFORMATION Resource Conservation and EPA Hazardous Waste NUmber(s)' None Recovery Act TRIM® SOL is not classified as a hazardous waste by EPA. 'toxic Substances . All TRIM' SOL ingredients are listed on the TSCA Inventory Control Act of Chemical Substances. Superfund'`'Aaendnents and TRIM® SOL does not contain any Section 302/304 Extremely Reauthorization Act of 1986 Hazardous Substances or Section 313 Toxic chemicals. Page 4 of 5 (TRIM' SOL) . �l ( _) 16. amp tneORMATIOH . -7\ LMIS Basard Index Mica RATINo Concentrate (Hnnith) H = 1 H = 1 (Fire) F = 1 F = 1 (Reactivity) R = 0 R = 0 (Rereonal 'Protection) 'PP = A _ Special hazards a none (safety glasses) Typical Working Solution , H = 1 H = F = 0 F = 0 R = 0 R = 0 PP = A (safety glasses) Special hazards. = none Roy 0 = minimal 1 = alight 2 = moderate 3 = serious 4 = severe Thii information is intended solely for the use of individuals trained in the particular , system. TAW is a registered trademark of Hester Chemical Corporation. (C) 1963 Master Chemical Corporation. The information herein is given in good faith and believed current as of the date of this MOS. Because conditions of use are beyond our control, no guarantee, representation or warranty:expressed or implied is made. Consult Master Chemical Corporation for further information. { Date of, preparation October 1995 • • Page 5 of 5 (TRIM® S0L) • 0 MA MEAL SAFETY DATA SHEET atanthr ua Compounds ROTO-BRITE L-555 Effective Date : December 11, 1992 • Manufacturer : ROTO-FINISH CO. , INC. ' 1600 Douglas Avenue Kalamazoo MI 49007 Kyle J. Eltblad (Mgr. Compound R&D) EMERGENCY ASSISTANCE For emergency assistance call CHEHTREC (800)424-9300A • For product information call Roto-Finish (616)327-7071 HAZARDOUS INGREDIENTS NO HAZARDOUS INGREDIENTS AS PER 29CFR 1910 . 1200 ' NOTE: Product is a biodegradable mixture of surfactants, buffers, lubricants and auxiliary materials . • j PHYSICAL & CHEMICAL CHARACTERISTICS Boiling point : Above 200 F Specific Gravity: 1 . 042 Solubility in water : Complete Reactivity in water :pH 1%:5 . 3 Appearance and odor : Mobile green liquid , cdorlelss FIRE AND EXPLOSION DATA Flash point : Not applicable Method used : TOC Special fire fighting procedures : Not applicable PHYSICAL HAZARDS (REACTIVITY DATA) Incompatibility (materials to avoid ) : Strong oxidizing agents Hazardous Decomposition Products : Oxides of carbon and nitrogen Hazardous Polymerization : Will not occur =L1" Uo en•2 it 11 l"JUJJ 'CCC '��ja'JY I IT I, 2 • ROTO-BRITE L-555 HEALTH HAZARDS INFORMATION Signs and symptoms of exposure : Over exposure could cause skin irritation with 'sensitive individuals Medical conditions generally aggravated by exposure : Unknown Emergency and first aid procedures: For over exposed areas, flush with plenty of water . For eyes, flush with plenty of water for 15 minutes and consult a physician . Inhalation : Unlikely - material not volatile In case of eye contact : Wash thoroughly - consult a physician • In case of skin contact : Wash thoroughly , If swallowed: Not applicable SPECIAL PRECAUTIONS AND SPILL/LEAK PROCEDURES Handling and Storage : Keep drum closed when not in use . Store away 'Prom excessive heat or cold . - Steps to be taken in case material is released or spilled : Spills should be absorbed on sand or sawdust and buried in an approved location, or flushed to drain with large amounts of water . Waste disposal methods : Material is completely biodegradable . Waste can be flused to drain in accordance with all Federal , State and Local regulations. , SPECIAL PROTECTION/CONTROL MEASURES Respiratory protection : Not applicable Ventilation : Not applicable Protective gloves : Rubber or Neoprene Eye protection : Safety glasses with side shields Work/Hygienic practices : Wash thoroughly after using H .H . I .S. RATINGS . Hazardous : 1 Flammability: 0 Reactivity: 0 MP (1 u'aClapay Building Prods iCampany 312 Walnut Street Suite 1600 Cincinnati,Ohio 45202-4036 USA (513)381-4800'Fax(513)762-3519 A Subsidiary of Clopay Corporalion November 26, 1996 do Mike Tausher ASI Construction Mt. Vernon, WA 98274 Via Fax(360) 428-0206 To Whom It May Concern, The Clopay Model 3200 garage door will withstand wind pressures of 16.4 PSF (pounds per square foot)with no additional reinforcement required to a maximum door width of 16'2". 16.4 PSF is equal to approximately 80 MPH wind speed. Sincerely, Mark Westerfield, P. Senior Product En_. eer TOTAL. P.01 (Th FROM : GOEDEI:E ` FHOIIE HO. : 206 644 5999 - ) 11o.... 20 199E 10:0,0h1 Fl GOEDEKE ENGINEERING 17119 SE 47th Court Bellevue, WA 98006-$805 phone/fax (208) 844-5899 FAX TR/_ N_SMITTAL TO: ASI Construction, Inc. PROJECT: Whispering Winds ATTN: Mike Tougher FROM: Gregg Goedeke DATE: 20 November 1998 PAGE 1 OF 2 COMMENTS: Mike: Attached is cal°sheet Page 1A responding to building department item 2, bolt design, under the subject of Building. Please call If there are additional items or questions. Thanks) • GOEPEI E CD IE I10. �n6 F�1.1 589A.--� 'lo... 2n 1995 ln:nc��d9 F^ .. - ... ►'.aS'-Y %,(716. . . . ... .w. €10;. I itA c - . 1 It - 1 • , pc, . /4 . , • _ . I_ 3 ,IIcp e 4II c' 3 i1 LP/ (N- . .. i 95 61It _ ... r7a al I aD� �tirX� 3 �. ... - 73 k '� 1 i rev.. P r jg, -�-2I,2 . . ' , S ,= 4 . ,r..V (c /A \/ ) cr. -� re, t 1. . pew. L' e • .v ... - .. .. U.i.. Y 1 ~ _I cI , 3. ,✓�rtro�4'. m, '� /TA Y[Y-: ^! '"7e" S Trbt 41.. I • 5 ((rr 199. ... � . „svr sr i b-r. .1a : t : II _ . I Li . MATERIAL SAFETY DATA SHEETS - - MSOS NO. 20b01 ISSUE GATE 12-Det-91 - MANUFACTURER: W,D.LOCKWOOD&CO.,INC. - - VI. EMERGENCY FIRST AID PROCEDURES ADDRESS: 81-83FRANKLIN STREET - NEW YORK. NY 10013 - INHALATION. IF INHALED.MOVE TO FRESH AIR.IF DIFFICULTY IN BREATHING.ADMINISTEI TELEPHONE: (212)966-4046 I 226-2878 OXYGEN AND GET IMMEDIATE MEDICAL ATTENTION, li I. PRODUCT IDENTIFICATION INGESTION IF SWALLOWED,GIVE SEVERAL GLASSES OF MILK OR WATER AND INDUCE VOMITING,GET IMMEDIATE MEDICAL ATTENTION,NEVER GIVE FLUIDS OR TRADE NAME: 360 EBONY BUCK INDUCE VOMITING IF PATIENT IS UNCONSCIOUS OR HAS CONVULSIONS. COLOR INDEX NAME: (SOLVENT BLACK 5 ) BLEND EYE CONTACT FLUSH EYES WITH FLOWING WATER FOR AT LEAST I5 MINUTES.IF IRRITATIC NOTE: INGREDIENTS NOT PRECISELY IDENTIFIED ARE PROPRIETARY AND NON- DEVELOPES,CONSULT A PHYSICIAN. HAZARDOUS. CHEMICAL FAMILY: SOLVENT DYE GAS HO, SKIN CONTACT. WASH AFFECTED AREAS THOROUGHLY WITH SOAP AND WATER.IF IRRITATIC CHEMICAL FORMULA: PROPRIETARY SOL.BK 5 1109903-9 DEVELOPES,CONSULT A PHYSICIAN.REMOVE AND LAUNDER CONTAMINATE T.S.C.A.STATUS: INGREDIENTS LISTED BASIC 8L I 3521-06.0 CLOTHING BEFORE REUSE. BASIC BL 26 2580-56.5 II. HAZARDOUS INGREDIENTS VII. REACTIVITY DATA COMPONENTS: NONE AS PER 29CFR PART 1910.1200 STABILITY' STABLE _ CONDITIONS 70 AVOID. NONE KNOWN POLYMERIZATION: WILL NOT OCCUR • INCOMPATIBLE MATERIALS: NONE KNOWN ' HAZARDOUS DECOMPOSISITION PRODUCTS: III. PHYSICAL DATA BURNING WILL PRODUCE OXIDES OF CARBON AND NITROGEN. APPEARANCE&ODOR: BLACK POWDER.SLIGHT ODOR SOLUBILITY IN WATER: SOLUABLE VIII. PRECAUTIONS FOR SAFE HANDING. USE AND DISPOSAL, STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: IV. FIRE&EXPLOSION DATA WHERE EXPOSURE IS NOT KNOWN,WEAR ANIOSH APPROVED OUST . RESPIRATOR.SWEEP OR SHOVEL SPILLS INTO A WASTE DISPOSALCOMAINE FLASH POINT; N/A - USE AN ABSORBANT TO PREVENT DUSTING.WASH DOWN THE AREA WITH WAT, EXTINGUISHING MEDIA: CO 2,DRY CHEMICAL OR WATER - - ( ' SPECIAL PROCEDURES FOR - WASTE DISPOSAL DISPOSE OF MATERIAL IN ACCORDANCE WITH ALL APPLICABLE FEDERAL ETA `/ FIGHTING FIRE: WEAR SCBA - AND LOCAL GOVERNMENTAL REGULATIONS. USUAL HAZARDS; AVOID DUSTING - - V. HEALTH HAZARD AFFECTS DATA IX. SPECIAL PROTECTION INFORMATION - ANIMAL TOXICITY. NOT ESTABLISHED FOR THIS PRODUCT, RESPIRATORY PROTECTION' NIOSH APPROVED DUST RESPIRATOR. VENTILATION- LOCAL EXHAUST TO MINIMIZE EXPOSURE. HUMAN EFFECTS. IN ORDER TO MAKE A PRECISE EVALUATION OF LOCKWOOD'S ABOVE PRODUCT - - - •6O EBONY BLACK . PLEASE READ THE ATTACHED . -PROTECTIVE GLOVES _ WEAR RUBBER OR NEOPRENE GLOVES. MSOS'S ASREFERED TO IN SECTION II'HAZARDOUS INGREDIENTS'. " - - - ASA STANDARD PRECAUTION WITH DYES ANO CHEMICALS,AVOID UNNECESSARY EYE-PROTECTION -WEAR-GOGGLES.WITH SIDE SHIELD IF NECESSARY. PERSONAL CONTACT, -OTHER._ WEAR LONG SLEEVE SHIRT,APRON.COVERALL TO MINIMIZE SKIN CONTACT. ' WA.NOTAPPLICAELE WE•NOT ESTABALISHED WO•NO DATA FOUND 1 - - ,�a�, - - - - - - ^\ PAGE2 PAGE? / 1 1 MSDS NO. - #60 EBONY BLACK 200-01 NOTE: EYEWASH FOUNTAIN SHOULD BE EASILY ACCESIBLE.WASH OR SHOWER AFTER HANDLING - MATERIAL OO NOT EAT OR SMOKE BEFORE WASHING HANDS THOROUGHLY.WORK CLOTHES SHOULD BE WASHED BEFORE REUSE. , • X. SPECIAL PRECAUTION MATERIAL SAFETY DATA SHEET • IN ACCORDANCE WITH GOOD INDUSTRIAL PRACTICE.HANDLE WITH DUE CARE AND AVOID PERSONAL CONTACT. XI. SHIPPING DATA DOT PROPER SHIP NAME: NOT REGULATED OOT HAZARD CLASS: N/A DOTLABELS: N/A - OWNA NUMBER: N/A R.O. N/A - XII. HMIS RATING - * e W. D. Lockwood&Co.,Inc.urges each customer or HEALTH-I redolent of this MSDS to study it carefully to become FIRE•1 aware of and understand the hazards negotiated with REACTIVITY-0 - the product. PROTECTION-SD • Disclaimer: W.0.Lockwood&Co,believes all the information and data given is accurate as of the date of cremation and Is offered In good fath.This inlormedon is given without warranty a representation sdely for you-consideration,investigation and verdication. Shea the condi- - 'lions of use ere beyond orr control,W.D.Lockwood&Co.,Inc. expressly disclaims all Iiabiity for the use or handling of this product. - - _ W,D-LOCKWOOD&CO.,INC. - _ 81-83FRANKUN ST. - - - _ NEWYORK,NY 1C013 - -- - - TEL(212)958•4O4B Y n PAGE) " - - - - - ^f ANACORTES PLANNING & COMMUNITY DEVELOPMENT DEPT. PERMIT CENTER 7 i*3 P.O. BOX 547, ANACORTES, WA 98221 I (360) 293-1901 -FAX (360) 293-1938 IAN MUNCE, DIRECTOR q 't EDWIN FRANK,BUILDING OFFICIAL COI February 5, 1999 Whispering Winds Attn.: Lynn Christoferson P.O. Box 1390 Anacortes,WA 98221 RE: New Addition 3116 V Avenue Permit No. COM98-0177 Dear Lynn: This letter shall stand as a temporary certificate of occupancy for the addition located at 3116 V Avenue. The temporary occupancy permit will expire 60 days from the date of this letter,at which time all corrections will need to be completed and a permanent certificate of occupancy will be issued. I If you have any questions,please feel free to contact me a 293-1901. Sincerely, CITY OF ANACORTES Don Measamer Plans Examiner DM:md cc. Dan Harju II PLUMBING PERMIT CITY OF ANACORTES PERMIT NO. : PLM98-0048 P.O. BOX 547 APPLIED: 11/19/98 ANACORTES, WA 98221 ISSUED: 11/25/98 (206) 293-1901 EXPIRES : 11/25/99 SITE ADDRESS : 3116 V ASSESSOR' S PARCEL NO. : 350230-2-223-0002 PROJECT DESCRIPTION: Plumbing for new building. — OWNER — CONTRACTOR WHISPERING WINDS COMMERCIAL PLUMBING P.O. BOX 1390 1023 COLLEGE WAY ANACORTES WA 98221 MT VERNON WA 98273 299-1485 428-5636 COMMEP1132MM TYPE OF WORK •NEW KIT SINKS W/DISP: 0 WTR PIPING/TREAT: 0 TYPE OF USE •COM WASHING MACHINES : 0 HOSE BIBBS • 0 ELEC WTR HEATERS : 0 GREASE TRAPS • 0 WATER CLOSETS . . . : 6 LAUNDRY TRAYS . . . : 0 ADD'L FIXTURES . . : 2 BATH TUBS • 0 URINALS • 1 SHOWERS • 1 WASTE INTERCEPT. : 0 DISHWASHERS • 0 DRINKING FOUNT. . : 0 LAVATORIES • 5 FLOOR DRAINS • 0 — FEES — NOTES Code Amount---- By- Date---- Receipt PRMT $ 125 . 00 MD 11/25/98 9300 PLCK $ 47 .50 MD 11/25/98 9300 TOTAL $ 172 . 50 I hereby acknowledge that I have read this permit and state the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Issued by Applicant or Owner' s Signature 24 Hour Notice Required For All Inspections plm_prmt, Rev: 06/11/92 7 MECHANICAL PERMIT CITY OF ANACORTES PERMIT NO. : MEC98-0110 P.O. BOX 547 APPLIED: 11/30/98 ANACORTES, WA 98221 ISSUED: 11/30/98 (206) 293-1901 EXPIRES : 11/30/99 SITE ADDRESS : 3116 V ASSESSOR' S PARCEL NO. : 350230-2-223-0002 PROJECT DESCRIPTION: Gas furnace and piping. — OWNER — CONTRACTOR WHISPERING WINDS RONK BROS INC. P.O. BOX 1390 837 E MOORE STREET ANACORTES WA 98221 SEDRO WOOLLEY WA 98284 299-1485 855-1025 RONKB**282N3 TYPE OF WORK. . . :ADD BOILERS/COMPRESSORS- DOMES . INCIN • 0 TYPE OF USE • COM 0-3 HP • 0 COMML. INCIN • 0 3-15 HP • 0 RELOC/REPAIR. . . : 0 FUEL TYPES 15-30 HP • 0 CLOTHES DRYERS . : 0 : /GAS/ / / : 30-50 HP • 0 GAS WTR HEATERS : 0 FURN < 100K BTU: 1 50+ HP • 0 STOVE, APPLI . . . : 0 FURN >=100K BTU: 0 AIR HANDLING UNITS-- FIRE LOG/LITE. . : 0 FURN - FLOOR. . . : 0 <= 10000 cfm. : 0 WOODSTOVES • 0 UNIT HEATERS . . . : 0 > 10000 cfm. : 0 OTHER UNITS • 0 VENT FANS • 0 EVAP COOLERS . . . : 0 GAS OUTLETS • 1 VENT SYSTEMS . . . : 0 HOODS • 0 VENT W/O APPLI . : 0 — FEES — NOTES Code Amount---- By- Date---- Receipt PRMT $ 43 . 05 MD 11/30/98 9314 TOTAL $ 43 . 05 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and Laws regulating activities covered by this permit. ( G/"Le,G-/� cv,„ P \20 Issued by Applicant or'1bwber' s Si e 24 Hour Notice Required For All Inspections mec_prmt, Rev: 06/11/92 • � I MEMORANDUM TO: Al Taylor FROM: Don Measamfv\ DATE: November 25, 1998 RE: Whispering Winds Revision The submitted revision dated 11/19/98 is approved with the following comments. The wood working area is shown as 914 square feet,not requiring an automatic sprinkler system per Section 904.2.5.1. However, equipment,machinery or appliances that generate finely divided combustible waste or that use finely divided combustible material shall be equipped with an approved method of collection and removal per Section 306.8. Please provide design for dust removal and specify equipment. If you have any questions feel free to give me a call at 293-1901. 11/19/1998 15:19 3602936613 PAGE 02 SENT BY: 11-19-98 ; 8:22 : FISHER & SONS, INC-' 3602936613;# 2/ 2 I1 -riJti f L CSF - .e i , ii, . • .ul z=t - 1 / 1 0.- - 1 \ 1 0 _ _I _ _. .__ _ - -. • r y-iL.i W tr I. . lz • • sitsvis. .. —atm , . 1 • �.� 11 \ M i =i 1 aa " @ .� = ` { s� 11/15/199E 15: 19 36029366,'=',, PAGE 03 SENT, BY: _ I-19-98 ; 10:35 ; FISHER & SONS,C _.IC-+ 3602936613;# 2/ 4 — - _ so'-o- 1- • .2ig . 0 a di iscl ._..n...�. _ .•.�+fin��..-,. a ,�� _ _.—s[.._3:r.—.c c..ry.., �J'.. T. • .1. I_I � CC' C -- ti u a; Tr 8 I CI C If. ' Re0104 gt 14 , • 40 o I•- x D> if 1 �6 /•' " � I 41No • . . ti . • • 4,44 .... • . . . •., .. . , . • • • • mow • • ., ,,. (r2 lir °:9'-Q` 4'-5 Vt. .1 IPIIIrr" . . , . - . • Qy �\ • 66 lit A 10"' -CD - 1,,,, . , y : tip... .. g • • [ � Q T.. .,, . take j. oee � F 1 n a m ! 1 W io d ( D [XISfING SWAPS 10 BE REYOYED A REPUGID mom, _ Ea 4 W/NEW MOS. TO BE LOCAIED IN PARRMC ! apyf.111711YK1YAY DIM ELEG �' 6. - ..,, . 4 .iiu iissflttWWWWWWi -_ iwi_ _ -z rat i w r r / I5'-0. / $'-C L es-es Id 5'-0s •5'-0 i I /2'', PROsir RUBBER / �'A'�`� tREAOS I (I� FitsisumT 1 a ® Foe o�+T �� �,�./� A%+�`" As ar , 4 �, . . . r r . r--, _' I 1 • 4. I / ^ti cn • co 01 S . — Il 4- v T. -�1 rj li 1 -Lli ki:41 ., �' s, l 4k ILii ari Itk ,ca � cn WOMEN'S RESTROOM 6 eASE J I/A'.!'-O' !SOLE: En . - / PROM( PRC-FORMED MI N61 WATER SUPPc �. •- • 'L ACCESSIBLE SINKS 1 , D ,JING M.T.C. Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST Report#C6738 CLIENT: Fisher& Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: September 23, 1998 DATE RECEIVED: September 24, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: Elevator Pit wall, spread footing at B.4 and spread footing and strip footing on C line from 1 to 5 lines SAMPLED AT: truck chute CONTRACTOR Fisher&Sons SUPPLIER CNW QUANTITY PLACED,CUIYD 20 yds MIX H&PROPORTIONS 5 �V2 SK w/AEA DELIVERY TICKET NO. 2111154 CEMENT, lbs. Not on ticket TRUCK NO. 152 FLYASH, lbs. BATCH TIME. 7:13 a.m. WATER, gals. SAMPLE TIME 7:35 a.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-I43) 4" COARSE AGGREGATE, lbs. AIR CONTENT, %(ASTM C-231) 3.5 COARSE AGGREGATE, lbs. AIR TEMPERATURE, °F 57o COARSE AGGREGATE, lbs. CONCRETE TEMP, °F(ASTM C-I064) 70n ADMIXTURE, oz.lcwt ADMIXTURE, m_lcwt COMPRESSION TEST RESULTS(ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA.(IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 129 7 9-30 104,000 5.97 27.99 3720 D.A N CAd"a mad`b a MTC'ppra "d"a 130 28 10-21 N ccTmdaw picked W by a Mit mrsavdadc 131 28 10-21 N Tat results comply with applicable specification dpSorda!AA wed sj,,nI spend s4 found H N mRcoagty Alap,oja+d*asd Rdnro.ama amd do,, d a complyu.— a pl.nand,secaamm.® Gans of water weas added O pdoraad O afters samPE REQ'D 28 -- - - - - 3000 REMARKS: MTC on site as requested for concrete inspection. Concrete was placed via truck chute and mechanically vibrated for consolidation. No exceptions. REPORTED BY: Stephen Barrie,Field Technician CHECKED BY: C. Shear,Laboratory Manager // DISTRIBUTION: original: Fisher&Sons,Inc. cc: City of Anacortes cc: cc: cc: cc: A..mmw Ti,the"The P md..mdv.a.ewa..'ndatimd as me anfida,wlp,pnty ofdmd.,ea naMib4m An rul6otio,ofA.Ivmd;.vchnins wawn u.°re nra.d..av maw.,®wd macaw,.mllm.pp°.A \ I M.T.C. ) Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST Report#C 6484 ThIENT: Fisher & Sons, Inc. PROJECT: Whispering Winds 4DDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: September 17, 1998 DATE RECEIVED: September 18, 1998 PERMIT#: FIELD DATA ' LOCATION OF PLACEMENT: Footing—A line 1-5, A-C line 1 SAMPLED AT: I CONTRACTOR Fisher SUPPLIER Concrete Nor'West QUANTITY PLACED, CU/YD 22 MIX#&PROPORTIONS 5 'ASK 3000 ' DELIVERY TICKET NO. 2111066 CEMENT, lbs. TRUCK NO. 37 FLYASH, lbs. BATCH TIME. 1:53 p.m. WATER, gals. SAMPLE TIME 2:28 p.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-143) 4 1/2' COARSE AGGREGATE, lbs. AIR CONTENT, %(ASTM C-231) 3.5% COARSE AGGREGATE, lbs. AIR TEMPERATURE, °F 59° COARSE AGGREGATE, lbs. CONCRETE TEMP, °F(ASTM C-1064) 72° ADMIXTURE, oz./cwt ADMIXTURE, oz./cwt COMPRESSION TEST RESULTS (ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA. (IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 045 7 9/24 122,500 6.0 28.27 4330 D.A. ® Cylinders made by a MTC representative 046 28 10/15 ® Cylinders picked up bye MTC representative 047 28 10/15 ® Test results comply with applicable specifcalion 048 Hold ® Reinforcng steel was visually Inspected antl found to comply with project plans antl specs Reinforcing steel does not comply with project plans and spec,lcations D Gallons of water were added n pnor to/a li after sampling REQ'D 28 - 3000 REMARKS: Concrete placed via truck chute and internally vibrated for consolidation. Resteel complies to details. Slab dowels wet stabbed after placement. REPORTED BY: Mike Westfall, WABO Certified Inspector CHECKED BY: C. Shear, Laboratory Manager DISTRIBUTION: original: Marc Estvold,AIA cc: cc: cc: cc: cc: ,,.n n,mr,u°„m re.,,,.m.n,d,er.,„d„n,d, ,.,ll,rn„n...,r.,,m,„,e n.,.,,,,,ilia,,'d i,°n.,,,.n rer,,,..,,,n„nm„,/.55 i,, p„uer.m°n m a.,n,,,r,n.r°„rm.i,,,.,,,..a,i,,w,,,,,,,r i ds,g°„r rrnmn i,rra,.rd pr„dn,•rnr vdee„•ppr°v.l 1687 Old Highway 99 So • Mount Vet non,Wa.98273 • Phone(360)428-0900 • FAX (360)428-6082 INSPECTION REPORT —r'KOJECT: Whispering Winds _ JOB NO: T8056F ADDRESS: Anacortes,WA REPORT NO: W1 GEOTEST SERVICES, INC. CLIENT: Fisher& Sons DATE: 12-10-98 741 Marine Drive CONTRACTOR: FabTech PAGE: 1 of 1 Bellingham,WA 98225 phone: 360.733.7318 WEATHER: Partly Sunny 42° INSPECTOR: DW fax: 360.733.7418 INSPECTION OF: Fabrication welding of stairs. THURSDAY DECEMBER 10, 1998 On site today at the fabricator FabTech to perform visual weld inspection ins accordance with the AWS D1.1-96 code. Verified WABO certifications for welders working on this project. The single fillet welds on the stair assembly was visually found to be acceptable to the requirements. No exceptions noted. Copies: Fisher& Sons Submitted By: 6'� Anacortes Building Department Grant Richardson Fab-Tech Materials Testing Manager wmain..n y This report shall not be reproduced except in full,without the written approval of GeraTest Services, Inc M.T.C. C) Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND MASONRY GROUT COMPRESSION TEST CLIENT: Fisher & Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: December 01, 1998 DATE RECEIVED: December 03, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: 5— 10', 2nd and final lift of wall for covered walkway, SE side of building SAMPLED AT: Truck chute before pumping CONTRACTOR Fisher& Sons SUPPLIER Concrete Nor'West QUANTITY PLACED,CU/YD 5 cu/yd MIX#&PROPORTIONS 7 SK 30/70 PG Grout DELIVERY TICKET NO. 2112124 CEMENT, lbs. TRUCK NO. 122 FLYASH, lbs. BATCH TIME. 9:15 a.m. WATER, gals. Not SAMPLE TIME 9;45 a.m. FINE AGGREGATE, lbs. On SLUMP, inches(ASTM C-143) 9" COARSE AGGREGATE, lbs. Ticket AIR CONTENT, %(ASTM C-231) __ COARSE AGGREGATE, lbs. AIR TEMPERATURE, °F 45° COARSE AGGREGATE, lbs. CONCRETE TEMP, °F(ASTM C-1064) 56° ADMIXTURE, oz.lcwt ADMIXTURE, oz./cwt COMPRESSION TEST RESULTS (ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA. (IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 1892 7 12/08 32,920 3.93 x 3.98 15.64 2100 C.S. ® Prisms made by a MTC representative 1893 28 12/29 70,300 4.12 x 4.08 16.81 4180 K.S. ® Pnsms picked up by a MTC representative 1894 28 12/29 68,900 4.13 x 3.96 16.35 4210 K.S. ® speestc alloncomply with applicable ® Reinforcing steel was visually Inspected and found to comply with project plans and specs Reinforcing steel does not comply with project plans and specifications 5 Gallons of water were added o prior tot❑ — after sampling. REQ'D 'a: ,; ni ?r `ylc":"4,3130%, 2000 ` 44» REMARKS: MTC on site prior to grouting. Reinforcement per 3/A4.1 and 1/A5. No exceptions taken. One set of three grout prisms cast. REPORTED BY. John Kepner, WABO Certified Inspector CHECKED BY: C. Shear, Laboratory Manager DISTRIBUTION: original: Fisher&Sons,Inc. cc: City of Anacortes✓ cc: A.n,nu,ud p,,en,ei io eLans,bc 1•ubi,,nu,l„nrs,Nn alt rgxms ne,,bnm,ed as Wa mnfdbpial prepenY eleliemt a,,rv,Lonm,ee for pobiicniee of su,nurnq caulos,sea or ea4rt6 Gom or,cganMg ee reporis s reserved pnWmg our wnncn epprevai 1687 Old I-Iighway 99 So. • Mount Vernon,Wa.98273 • Phone(360)428-0900 • FAX(360)428-6082 /r1 M.T.C. Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND MASONRY GROUT COMPRESSION TEST CLIENT: Fisher & Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: December 01, 1998 DATE RECEIVED: December 03, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: 5— 10', 2nd and final lift of wall for covered walkway, SE side of building SAMPLED AT: Truck chute before pumping CONTRACTOR Fisher& Sons SUPPLIER Concrete Nor'West QUANTITY PLACED, CU/YD 5 cu/yd MIX#&PROPORTIONS 7 SK 30/70 PG Grout DELIVERY TICKET NO 2112124 CEMENT, lbs. TRUCK NO. 122 FLYASH, lbs. BATCH TIME. 9:15 a-m. WATER, gals. Not SAMPLE TIME 9:45 a.m. FINE AGGREGATE, lbs. On SLUMP, inches(ASTM C-143) 9" COARSE AGGREGATE, lbs. Ticket AIR CONTENT, %(ASTM C-231) _- COARSE AGGREGATE, lbs. AIR TEMPERATURE, "F 45o COARSE AGGREGATE, lbs. CONCRETE TEMP, "F(ASTM C-1064) 56° ADMIXTURE, oz./cwt ADMIXTURE, oz/cwt COMPRESSION TEST RESULTS(ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA. (IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 1892 7 12/08 32,920 3.93 x 3.98 15.64 2100 C.S. Prisms made by a MTcrepresenlanve 1893 28 12/29 ® Prisms picked up by a MTC representative 1894 28 12/29 p Test reswls comply with applicable speciticabon EReinforcing sleet was visually Inspected and 'ON found to comply with project plans and specs ❑ Reinforcing sleet does not comply with project plans and specifications 15 Gallons of water were added ❑prior to/❑ REQ'D t'-1 iY:rn+ r.:+"w' 33 after sampling '�:yU -,1'j 2000 REMARKS: MTC on site prior to grouting. Reinforcement per 3/A4.1 and 1/A5. No exceptions taken. One set of three grout prisms cast. • REPORTED BY. John Kepner, WABO Certified Inspector CHECKED BY: C. Shear, Laboratory Manager 1 DISTRIBUTION: original: Fisher&Sons,Inc cc: City of Anacortes J cc: ♦,„omoai„om,„w W d,eutl 1110 p„m,..,,d,,,,,,u+c..al,y.,,,..,,sobomod a,me,vmta.,,,m p.oponr"ral.ias..,w.meon."lon for pee.moo orsum„c„o.."o.m.o,m",.alit.raw.r«s.m„is our iepons,s r,w,vcd psi,,iee our wnuc„approve I687 Old Highway 99 So. • Mount Vernon,Wa 98273 • Phone(360)428-0900 • FAX(360)428-6(182 M.T.C. Materials Testing & Consulting, Inc. 1. REPORT OF FIELD INSPECTION AND MASONRY GROUT COMPRESSION TEST CLIENT: Fisher & Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: November 17, 1998 DATE RECEIVED: November 19, 1998 REPORT#: FIELD DATA LOCATION OF PLACEMENT: South entrance -wall 0'to 4' SAMPLED AT: End of pump CONTRACTORS Gen./Sub. Fisher/All Masonry SUPPLIER Concrete Nor'West QUANTITY PLACED,CU/YD 8 MIX#&PROPORTIONS 7 SK 30/70 PG Grout DELIVERY TICKET NO. 2112008 CEMENT, lbs. TRUCK NO. 163 FLYASH, lbs. BATCH TIME. 9:33 a.m. WATER, gals. SAMPLE TIME 12:30 p.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-143) 10" COARSE AGGREGATE, lbs. AIR CONTENT, %(ASTM C-231) -- COARSE AGGREGATE, lbs. AIR TEMPERATURE, °F 46° ADMIXTURE, oz/cwt. CONCRETE TEMP, °F(ASTM C-1064) 56° ADMIXTURE, oz./cwt ADMIXTURE, oz./cwt COMPRESSION TEST RESULTS (UBC 21-18 or 21-17) LOG TEST DATE OF TOTAL LOAD SPECIMEN AREA COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) SIZE. (IN.) (SQ.IN.) STRENGTH BY (DAYS) (PSI) 1759 7 11/24 38,910 4.05 x 4.14 16.77 2320 C.S. ® Prisms made by a MTC representative 1760 28 12/15 ® Prisms picked up by a MTC representative 1 761 28 12/15 ® Test results comply with applicable spec1orcing ® Reinforcing sleet was project ylans ed and found to comply with protect plans and specs Reinforcing steel does not comply with protect plans and specifcations Gallons of water were added ❑prior to/❑ after sampling REO'D 28 REMARKS: Reinforcement checked prior to placement for size, clearance and spacing. Pilaster rod had #5 strings at 16" on center. Grout placed by pump and vibrated internally. One set of three grout prisms cast. REPORTED BY: John Kepner,WABO Certified Inspector CHECKED BY: Curt Shear, Laboratory Manager Cj DISTRIBUTION: original: Fisher& Sons, Inc. cc: City of Anacortes✓ cc: Concrete Nor'West cc: cc: cc: Y..,n,mwl Pumamnwtl,a,b WC iwbhc,md 11, II all uryno uc r,L,nn¢Js Nc mulWa,wl pruVenY°ftl,en,c.u,W anLnmamnfu,Pubbonmmfsu,enm„isomtlusrvne mnwas free°rree,ud,,ewrewn,,smscncdpen4,,,genrwnnmupPmwi 1687 Old Highway 99 So • Mount Vernon,Wa. 98273 • Phone(360)428-0900 • FAX(360)428-6082 M.T.C. Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST Report(IC 6786 CLIENT: Fisher & Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: October 29, 1998 DATE RECEIVED: October 30, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: 211d story slab, gridlines C-B and 1-5 SAMPLED AT: Truck chute, middle of 2"d truck CONTRACTOR Fisher& Sons SUPPLIER Concrete Nor'West QUANTITY PLACED,('IFYD 40 cu/yd MIX N&PROPORTIONS 6 SK DELIVERY TICKET NO 2111740 CEMENT, lbs. T RUCK NO 122 FLYASH, lbs. BA rCII TIME 7:39 a.m. WATER, gals. SAMPLE TIME 8:15 a.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-143) 4" COARSE AGGREGATE, lbs. AIR CONTENT, 96(ASI NI('-231) N/A COARSE AGGREGATE, lbs. AIR TEMPERATURE, °Il 56° COARSE AGGREGATE, lbs CONCRETE TEMP, °P(AS I'M C-I064) 65° ADMIXTURE, oz./cwt ADMIXTURE, oz/cwt COMPRESSION TEST RESULTS(ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA (IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 1241 7 11/05 122,500 5.995 28.23 4340 C.S. ® Cylindeis made by a MTC representative 1242 28 II/26 159,000 6.0 28.27 5620 C.S. ® Cylinders picked up by a MTC representative 1243 28 II/26 162,500 6.0 28.27 5750 C.S. ® Test results comply with applicable specification 1244 Hold ® Retoincofmorcplyingw sittehelprwasoject visuallyplansand inspectespecsd and found ❑ Reinforcing steel does not comply with project plants and specifications 1 s Gallons of water were added 0 print to/❑after ampling REQ n 28 ' 4000 REMARKS: Concrete placed via pump truck and monitored by MTC for slump and temperature. One set of four cylinders cast. REPORTED BY: Brian Steele, Field Technician CHECKED BY: C. Shear, Laboratory Manager t/ DISTRIBUTION: original: Fisher&Sons,Inc. cc: City of Anacortes cc: Concrete Nor'West cc• cc: cc: \v in°w+Iluucamn m Jwro rile public mdnnnat.a.+Ii,epnns use subinntN as the coo(Jnnial property of clients,and aullmrimiron Inc pubLuuou oRum,nenl,,aonelusmns or exnacu from or regarding our reports is reserved pmtliny our wnitnnpprovd 1687 Old Highway 99 So. • Mount Vernon,Wa.98273 • Phone(360)428-0900 • FAX(360)428-6082 M.T.C. r s Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST Report#C6540 CLIENT: Fisher& Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: October 01, 1998 DATE RECEIVED: October 02, 1998 PERMIT#: FIELD DATA • LOCATION OF PLACEMENT: Slab area from 1 to 5 line and A to 10' N of B ; Footing on 5 line from B to C SAMPLED AT: Pump Hose CONTRACTOR Fisher& Sons SUPPLIER Concrete Nor'West QUANTITY PLACED,C•U/YD 70 of 106 cu/yd MIX#&PROPORTIONS 5.5 SK µr/WRA&AEA DELIVERY TICKET NO 2111285 CEMENT, lbs. "I IUJCK NO 37 FLYASH, lbs. I BATCH TIME. 9:18 a•rn. WATER, gals. SAMPLE TIME 9:35 a.m. FINE AGGREGATE, lbs SLUMP, inches(ASTM C-143) 6" COARSE AGGREGATE, lbs. i AIR CONTENT, %(ASrM C•-23I) 4.0% COARSE AGGREGATE, lbs. AIR TEMPERATURE. 'I' 63° COARSE AGGREGATE, lbs. o ADMIXTURE, oz./cwt Pozz Tec 20 0 ONCRrrE"rE6u lmr(ns rna c-un,4) 68 .25/o ADMIXTURE, oz/cwt COMPRESSION TEST RESULTS(ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA.(IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 421 7 10/08 98,000 6.0 28.27 3470 D.A. ® Cylinders made by a MTC repiesentauve 422 28 10/29 136,500 6.0 28.27 4830 - D.A. ® Cylinders picked up by a Ant eepresenlative 423 28 10/29 139,000 6.0 28.27 4920 D.A. ® Test esults comply wills applicable specilicauon 424 ' Hold ® Rninforc'ngs¢el was visuallyinspected and found - tiles comply with project plans and specs ❑ Reinforcing steel does not comply with project plans and specifications Gallons of water were added O prior to/❑after __ sampling REQ'n 28 .yo.35tq :'...` Pfi -s REMARKS: MTC on site as requested for concrete inspection in areas noted above. Concrete was placed via pump truck. Concrete mechanically vibrated in footing areas and hand screed in slab areas for consolidation. Contractor. informed MTC that if necessary, lie will protect slab from rain. REPORTED BY. Stephen Barrie,Field Technician CHECKED BY: C. Shear,Laboratory Manager/ DISTRIBUTION. original: Fisher&Sons,Inc. cc: City of Anacortes✓ cc: Concrete Nor'West cc' cc: cc: n aiwtput plateau.ma dicta,W,piltt alma inn ivoa all rdhon:moo snbnnned as thc coordmnd propcoy or clients awl audmn.anon for publication or:Y¢mcmc conclusions or euuas(ruin or«µammg our reps¢is mooned penning our written appioval 1687 Old Highway 99 So. • Mount Vernon,Wa.98273 • Phone(360)428-0900 • FAX(360)428-6082 M.T.C. Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST Report#C6738 CLIENT: Fisher& Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: September 23, 1998 DATE RECEIVED: September 24, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: Elevator Pit wall, spread footing at B.4 and spread footing and strip footing on C line from 1 to 5 I lines SAMPLED AT: truck chute CONTRACTOR Fisher&Sons SUPPLIER CNW QUANTITY PLACED,CU/YD 20 yds MIX tt&PROPORTIONS 5 '/a SK w/AEA DELIVERY TICKET NO. 2111154 CEMENT, lbs. Not on ticket 1 TRUCK NO 152 FLYASH, lbs. BATCH TIME. 7:13 a.m. WATER, gals. SAMPLE TIME 7:35 a.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-143) 4" COARSE AGGREGATE, lbs. AIR CONTENT, %(ASTM C-231) 3,5 COARSE AGGREGATE, lbs. AIR TEMPERATURE, °F 57° COARSE AGGREGATE, lbs. I CONCRETE TEMP, °F(ASTM C-1064) 70° ADMIXTURE, oz./cwt 1 ADMIXTURE, oz./cwt COMPRESSION TEST RESULTS(ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA.(IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 129 7 9-30 104,000 5.97 27.99 3720 D.A. ® Cylinders made by aMTC representative 130 28 10-21 138,000 5.997 28.25 4880 G.B. ® Cylinders picked up by a MTC representative 131 28 10-21 137,000 5.997 28.25 4850 G.B. ® Test results comply with applicable specification 132 H Ei Reinforcing steel was visually mspeaed and found to comply with project plans and specs Reinforcing steel does not comply with project plans and specifications Gallons of water were added ❑prior for❑after -- sampling REQ'D 28 +i '5rd e',tR,. n„ fe1 . Ji,.S Is; S'd *a+"3:r;,, o it +.', 3000 i REMARKS: MTC on site as requested for concrete inspection. Concrete was placed via truck chute and mechanically vibrated for consolidation. No exceptions. REPORTED BY. Stephen Barrie, Field Technician CHECKED BY: C. Shear,Laboratory Manager DISTRIBUTION: original: Fisher&Sons,Inc. cc: City of Anacortes/ cc. cc: cc: cc: Asnnmu.I pmurnoi,to cheats the pub he out oursehn.11 repens aresubmiiie mbe eosldatWl ptnpeny aregets,and soJmnuUmt rut publication ofsmoaneses.conclusio,u or exuens fmn,or myudmg ounepans is reserved pe„ding ou watt uppenval 1687 Old Highway 99 So. • Mount Vernon,Wa.98273 • Phone(360)428-0900 • FAX(360)428-6082 4 c 's l M.T.C. C Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST CLIENT: Fisher& Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: October 05, 1998 DATE RECEIVED: October 06, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: Interior slab A.75-C line 1-5 and West side cantilever retaining wall SAMPLED AT: Middle of 4d' load at 40 cu/yd CONTRACTOR Fisher& Sons SUPPLIER Concrete Nor'West QUANTITY PLACED,CU/YD 100 MIX#&PROPORTIONS 5.5 SK DELIVERY TICKET NO 40228 CEMENT, lbs. TRUCK N() 103 FLYASII, lbs BATCH TIME. 8:15 a.m. WATER, gals. 1 SAMPLE TIME 9:15 a.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-I43) 3 Viz" COARSE AGGREGATE, lbs AIR CONTENT, %(ASTM C-23I) NI/A COARSE AGGREGATE, lbs AIR TEMPERATURE, °F 570 COARSE AGGREGATE, lbs. CONCRETE TEMP, °F(ASTM C-I064) 68° ADMIXTURE, oz./cwt ADMIXTURE, oz./cwt COMPRESSION TEST RESULTS(ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA.(IN.) AREA STRENGTH BY (DAYS) (SQ.IN.) (PSI) 475 7 10/12 112,000 6.0 28.27 3960 D.A. ® Cylindets made by a M111C rep esenlalive 476 28 11/02 ----- z CYhndcrs picked up by a MT(representative 477 28 11/02 --_-_ ❑ Tea results comply nab applicable specification 478 Hold -----_ ® i compl ny meet rrus vl lanlly m sieecs and found m comply with profen plans ain specs ------- __--_-_ plalansnfureandms vestiricmio does not comply With plofen ---_ p specns -_----_ 5 pns of warm wens added 1g Pnui Oil p afmr sampling REQ' ) 28 t. . " hf4' .w t. ml01)<l,l,:„l',. 4000 > i REMARKS: Concrete placed via pump truck and thickened edge slab internally vibrated for consolidation. . REPORTED BY: Mike Westlall,WABO Certified Inspector CHECKED BY:: C. Shear, Laboratory Manager✓ DISTRIBUTION: original: Fisher&Sons, Inc cc: City of Anacortes✓ cc: Concrete Nor'West cc: cc: cc: As unu at pmua,wno tlunis.the public slid ounelva.all,epons are submittal as 1be coofJenWl prvpeny°ftlbns.aid+unmmauon for publication of mmnrzme murlusmns or exvuns from or nyadinµ ow repans n reserved pending our arsoaupproval 1687 Old Highway 99 So. • Mount Vernon,Wa.98273 • Phone(360)428-0900 • FAX(360)428-6082 1 , 1 �) M.T.C. (IN' Materials Testing & Consulting, Inc. REPORT OF FIELD INSPECTION AND CONCRETE COMPRESSION TEST Report#C 6484 CLIENT: Fisher& Sons, Inc. PROJECT: Whispering Winds ADDRESS: Post Office Box 534 FILE NO: 980911 Burlington, WA 98233 DATE CAST: September 17, 1998 DATE RECEIVED: September 18, 1998 PERMIT#: FIELD DATA LOCATION OF PLACEMENT: Footing—A line 1-5,A-C line 1 SAMPLED AT: CONTRACTOR Fisher SUPPLIER Concrete Nor'West QUANTITY PLACED,CU/YD 22 MIX#&PROPORTIONS 5 'ASK 3000 DELIVERY TICKET NO. 2111066 CEMENT, lbs. TRUCK NO. 37 FLYASH, lbs. BATCH TIME. 1:53 p.m. WATER, gals. SAMPLE TIME 2:28 p.m. FINE AGGREGATE, lbs. SLUMP, inches(ASTM C-143) 4 +%" COARSE AGGREGATE, lbs. AIR CONTENT, %(ASTM C-231) 3.5°/p COARSE AGGREGATE, lbs. AIR TEMPERATURE, °F 59° COARSE AGGREGATE, lbs. CONCRETE TEMP, °F(ASTM C-1064) 72° ADMIXTURE, oz./cwt ADMIXTURE, oz./cwt COMPRESSION TEST RESULTS (ASTM C-39) LOG TEST DATE OF TOTAL LOAD CYLINDER CYLINDER COMPRESSIVE TESTED OBSERVATIONS NO. AGE TEST (LBS) DIA. (IN.) AREA STRENGTH BY 'I (DAYS) (SQ.IN.) (PSI) i 045 7 9/24 122,500 6.0 28.27 4330 D.A. ® Cylinders made by a MTC representative 046 28 10/15 147,500 5.99 28.18 5230 C.S. ® Cylinders picked up by a MTC representative 047 28 10/15 149,000 5.99 28.18 5290 C.S. ® specifecaboncompty with applicable 048 Hold El Reinforcing steel was visually inspected and found to comply with project plans and specs ❑ Reinforcing steel does not comply with project plans and specifications 0 Gallons of water were added ®prior to/❑ � — after sampling. REQ'D 28 ii"}Z F-yS' 4 a .tirhi`.. ,: ::1:I;i0 „tI'.a$ J' l;T.,e—e 3000 �sp,,°t-,;1 REMARKS: Concrete placed via truck chute and internally vibrated for consolidation. Resteel complies to details. Slab dowels wet stabbed after placement. REPORTED BY: Mike Westfall, WABO Certified Inspector CHECKED BY: C. Shear, Laboratory Manager DISTRIBUTION: original: Marc Estvold,AIA cc: cc: cc: cc: cc: n..,,,mdt�uu<n°„moernn n,°p°m,a„dsandt.m,allrean.arc..e°nuea as ni,caatidmii.l puny aidtrats.aid.,Dies,..u°„m,vabe.a,°„°func,ar,ns.co,crosimu or seine,:rc°°,°„°y.m,,,s°°mpona is reserved p°„m„k°a,.nua„appr°•e III 1687 Old Highway 99 So. • Mount Vernon,Wa.98273 • Phone(360)428-0900 • FAX(360)428-6082 ) GY o� ANACORTES PLANNING & COMMUNITY DEVELOPMENT DEPT. PERMIT CENTER `'' P.O.BOX 547,ANACORTES,WA 98221 • (360)293-1901 - FAX (360)293-1938 UNCE, CTOR , EDWIAN IIN FRANK,BUILDING OFFICIAL July 29, 1998 Marc Estvold, Architect 3110 Commercial Avenue Anacortes, WA 98221 RE: Whispering Winds The following comments are based on the plans received July 8, 1998. Please respond to all comments in written form and by revising the plans as necessary. Use Zone: Industrial Lot Area: 53,976 square feet Lot Cover: 26,988 square feet allowed (50%) 16,000 square feet proposed Floor Area: Existing first floor: F-2 5,487=occupant load 27 Existing first floor: B 513 square feet=occupant load 5 Sub Total 6,000 square feet Existing second floor:B 1,440 square feet=occupant load 14 Existing second floor: F-2 1,012 square feet= occupant load 5 Sub Total 2,452 square feet Existing building: 8,452 square feet Proposed Floor Area Totals First floor: F-2 15,487 square feet=occupant load 77 First floor: B 513 square feet=occupant load 5 Sub Total 16,000 square feet first floor 'a Second floor: F-2 5,900 square feet=occupant load 29 Second floor: B 1,440 square feet=occupant load 15 • Sub Total 7,340 square feet y IA Total Building Size: 23,340 square feet Type of Construction: VN allowable area using separation on two side's 16,050 square feet, OK Number of Floors: Two 00 10 Building Height: 30 feet Parking: 31 spaces required 51 spaces shown 8 bike spaces required SITE/GENERAL /r<IT/�We have used an allowable area increase based on separation of two sides, east property line and south property line. The rail road right-of-way has not yet been designated City right-of-way. Allowable area using the two sides is 16,050 square feet. OK ( 2) Please provide a copy of a recent survey. Y Ni-'-" SPlease provide a complete plan indicating types of plants, size of plants and locations. Provide civil drawings indicating drainage needs, sanitary sewer locations and sizes, domestic water locations and sizes, parking lot elevations,parking stall sizes, etc. ��i F, v L,_ c. , o l Show bike rack locations. 4 Landings need to be shown for all stairs and doors. It will be necessary to show Department of Ecology approval for the re- configuration of the existing waste sump. BUILDING Complete plumbing and mechanical applications. l'v 9ux ' : 9 ( Provide mechanical sheets per NREC checklist. Cs, -4 s .s .....3r•RNI 0 How is the R-19 insulation held between the roof purlins? 4✓ Radiant slab insulation Beds to be provided for a total of 36 inches per NREC Section 1311.6. 1 o5. Which spaces are fully heated and semi heated,please verify. Provide manufacturers cut sheets to the mechanical drawings for all thermostats. NREC Section 1310.2. g_eAJ.Suo �6 Provide metal building engineering and structural concrete engineering. The existing pre-engineered building will need to be evaluated for the new roof structure connected to it. enn-1-d 7. The pre-engineered steel building f bricator must be an approved fabricator. 1 2 Marc L. Estvold Architect, Inc. PS, AIA 3110 Commercial Avenue, Suite 102-D Anacortes,WA 98221 Fax(360)293-6613 Phone (360)293-5500 FAX TRANSMISSION DATE: 11/19/98 3:08 PM NO. OF PAGES: Z- (including this page) RECEIVING FAX# : 293-1928 PROJECT NAME : WHISPERING WINDS TO COMPANY: ANACORTES BUILDING DEPT ATTENTION: DON MEASAMER CC: REMARKS: I SPOKE WITH JON AT WHISPERING WINDS ABOUT THE WOODWORKING AREA AND HE SAYS THAT THEY WILL BE DOING PROTOTYPE DISPLAYS SO THERE WILL BE CUTTING & SANDING TYPE WORK BEING PERFORMED IN THIS 914 S.F. AREA THE OTHER AREA WILL REMAIN AS RACK ASSEMBLY AS ORIGINALLY SUBMITTED JUST SMALLER NOW. PLEASE CALL ME AT YOUR CONVENIENCE. Copy to follow via mail Yes No IF YOU HAVE TROUBLE RECEIVING THIS TRANSMISSION PLEASE CALL: (360) 293-5500 fax (360) 293-6613 TO 39t7d ET99E6309E 6T5T 0661/6T/TT C�> Memorandum To: Dave Lervik From: Don Measamer Date: 09/03/98 Re: Whispering Winds Storm Drain GFC Whispering Winds at 3116 V Place is developing 29,815 square feet of pervious area to impervious surfaces. Please verify the following 29,815 square feet+2,000 = 14.9075x$1,126.00 = $16,785.84. Please let me know if you concur. �,,'j/' am/j rtOR L 9/3/98 gave Lervik Date 1 • I ap,S---- o Qrses`'0 aka lee STATE OF WASHINGTON DEPARTMENT OF ECOLOGY Northwest Regional Office, 3190 - 160th Ave 5.E. • Bellevue, Washington 98008-5452 • (425) 649-7000 August 12, 1998 Ms. Lynn M. Christofersen P.O. Box 1390 Anacortes, WA 98221 Dear Ms. Christofersen: I have reviewed the information you have provided on your plant addition. If you are not anticipating an increase in the quantity of the discharge or the quality of the discharge after the pretreatment system the Department of Ecology would still be considered not unlike domestic sewage in both quality and volume. The discharge would contain no toxics that could interfere or upset the City of Anacortes wastewater treatment plant. Based on this, your operation would not require a State Wastewater Discharge Permit from the Department of Ecology. If there are other questions on this please contact me at (425)649-7046. Sincerely, Robert Newman Water Quality RN:clm cc: Don Measamer, City of Anacortes ° CO Memorandum To: Jim Pemberton From: Don Measam Date: 07/29/98 Re: Whispering Winds, 3116 V Avenue Whispering Winds is proposing an addition, which would include the following sanitary fixture units. Water Closets 5x4 = 20 fixture units Lavatory 4x1 = 4 fixture units Urinal 1x3 = 3 fixture units Floor Drains 2x2 = 4 fixture units Janitor Sink 1x2 = 2 fixture units Total 33 fixture units The existing building has 27 fixture units that will be remaining. Please calculate the sewer GFC required. Thank you. a/416 � � g we3 ► / e o Memorandum To: Ian Munce From: Don Measame`h Date: 07/29/98 Re: Traffic Impact Fee Whispering Winds Whispering Winds, 3116 V Avenue, is proposing to add 14,888 square feet of manufacturing area to their existing facility. Using No. 110 of the trip generation schedule would be consistent with the previous impact fee calculation and again seems to be fit the use. #110 = .42x14.888 = 6.25296x$400.00 = 2,501.18. The total traffic impact fee for the addition would be $2,501.18. Please let me know if you concur. Thank you. 8398 Ian Munce Date I G\1 Y 0.4 CITY OF ANACORTES COMMUNITY DEVELOPMENT DEPARTMENT y � PERMIT :,ENTER— 904-6TH STREET '., YWICATE:OF OCCUPANCY • - This Ao,ceidfy that the oa;upancy lsted`liereon has been inspected and is'hetebtapprovedtot-use. 3116 V Avenue C0M96-0249 Address of Building/hernias Building Permit No Whispering Winds Occupant - Suite No. Bunions Registration No. Whispering Winds, Inc. — John Metzger 5N F2, B Owner Type of Construction Type of Occupancy ' r-y 762 Padilla Rte., Anacortes, WA 98221 Industrial i Address of Owner Zoning District . Maximum Occupancy Load F2+25, B.a22 1,2.5a074 sq.ftt — B=2,251 sq.ft. Square Fat Statwnant of Restrictions t issued .In �pection Apprival: ru, ed sy �cr--.. \ Xls 1.—a-1-01") Fire Marsha • Date Budding Official Date HIS CERTIFICATE T ; �,I'SP14vEp iwetwc AKA _Wayland 5-89 TO BE RENIOV .,.t I'.F°I EIBOILOING OFF JAL 41/4AS( -2.kt-`i- Lk - ---- - ---- --- - - - - 02-2\-n-7 P,w --te0c,-14 C .- 'tili - - e,2,e 1 . .k L 1.v - - n Ca 911 y7��. ki 561-c- 4, 13t 50 -C Axis,' COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : COM96-0249 P.O. BOX 547 APPLIED: 12/05/96 ANACORTES, WA 98221 ISSUED: 12/09/96 (206) 293-1901 EXPIRES: 12/09/97 SITE ADDRESS: 3116 V ASSESSOR'S PARCEL NO. : 3116 PROJECT DESCRIPTION: 60x100 Steel building with office and restrooms. — OWNER — CONTRACTOR — LENDER WHISPERING WINDS AXTHELM & SWETT CONSTRUCTION P.O. BOX 1390 1751 CEDARDALE ROAD ANACORTES WA 98221 MT VERNON WA 98273 299-1485 424-6282 AXTHC166RA I, — FEES TYPE OF WORK •NEW AREA (sf) VALU...$: 290000 Code Amount---- By- Date---- Receipt TYPE OF USE •COM LOT • 24160 REQUIRED SETBACKS---- ESPL $ -847.00 DM 12/09/96 6248 CENSUS CATEGORY •999 1ST FLR • 6000 FRONT • 0 ft PLCK $ 847.93 DM 12/09/96 6248 ZONING 2ND FLR 0 SIDE(1)..: 0 ft PRMT $ 1304.50 DM 12/09/96 6248 :I BASEMENT • 0 SIDE(2)..: 0 ft PMEC $ 51.50 DM 12/09/96 6248 OCCUPANCY GROUP GAR/CARPORT...: 0 REAR 0 ft PPLM $ 111.00 DM 12/09/96 6248 :B :F2 •? •? OTHER 0 REQUIRED PARKING-- STBC $ 4.50 DM 12/09/96 6248 TYPE OF CONSTRUCTION TOTAL • 0 SEWR $ 3333.00 DM 12/09/96 6248 :5N •? •? :? : NUMBER OF UNITS • 1 ACCESSIBLE.: 0 IMPT $ 1420.00 DM 12/09/96 6248 OCCUPANT LOAD STORIES • 1 COMPACT • 0 INSP $ 50.00 DM 12/09/96 6248 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0 FURN < 100K BTU: 2 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 6275.43 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 0 FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 1 — NOTES UNIT HEATERS...: 1 50+ HP • 0 STOVE, APPLI...: 0 VENT FANS • 0 AIR HANDLING UNITS-- FIRE LOG/LITE..: 0 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 W00DSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 4 HOODS • 0 WATER CLOSETS...: 3 WASHING MACHINES: 0 FLOOR DRAINS • 1 BATH TUBS • 0 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 1 SHOWERS • 0 LAUNDRY TRAYS...: 0 HOSE BIBBS • 2 DISHWASHERS • 0 URINALS • 0 GREASE TRAPS • 0 LAVATORIES • 3 WASTE INTERCEPT.: 0 ADD'L FIXTURES..: 2 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Ty-i---, A ant i 6 criAcjigo Issued by Ap i ant or wner' s Signature 24 HourNotice Required For AllInspections comy 4 I�rmt, Rev: 11/04/93 ^r4 " A W ,,,,„ Ayt Pk a /�l q'2 u x i e'� 1 MEMORANDUM DATE: November 18, 1996 TO: Jim Pe FROM' on MeasameOrn RE: Please calculate sewer gfc for the Whispering Winds project located at 3116 V Place based on the fixtures listed below. Water Closet 3 x 4 = 12 Lavatories 3 x 1 = 3 Kitchen Sinks 2 x 2 = 4 Washer 1 x 2 = 2 Floor Drains 3 x 2 = 6 Total 27 Plans are available at the Building Department if needed. JAM FG bS ! GAR ev 5- 0arenec(lY G�` � beaus o r So os.tvc 3 • �� = * 3333. 00 r 0 MEMORANDUM DATE: November 15, 1996 TO: Ian Munce C G/ / FROM: Michelle Deaton t° 0` ISM I J jg/ !c RE: Impact Fees for Whispering Winds - 3116 V Place {{{ I calculated the following impact fees for Whispering Winds. 8,449 Square feet of light manufacturing use. Code 110 - Light Industrial/Industrial Park- 8.449 x 0.42 = 3.55 x 400 = $1,420.00. IIERRIGSTAD ENGINEERING Civil Engineer 3001 R Avenue,Suite 210B Dale Herrigstad,P.E. Anacortes,WA 98221 (360)299-8804 WHISPERING WINDS DEVELOPMENT DRAINAGE ANALYSIS October 14, 1996 PROJECT DESCRIPTION: Whispering Winds is developing a 41,701 Sq.ft. lot for commercial purposes. This analysis is to determine the capacity of the downstream storm water drainage system to handle a 100 year storm event for the drainage basin. The existing site is covered by grass. See the attached layout.Plan#1,to show the drainage basin for the area surrounding this development. RESULTS OF ANALYSIS: The following analysis is a conservative analysis of the basin in question and increase of runoff due to the commercial development will be .51 cfs for the 100 year storm event. The downstream analysis shows excellent pipe capacity to the outran of the pipe network at Paddilla Bay. See Plan drawings for pipe capacities at 100 year flow levels. ON SHE DRAINAGE ANALYSIS: The site existing condition is primarily grass and shrubs. The Soil Conservation Service(SCS)maps soil as Bow-Urban land complex,0 to 8 percent slopes and a hydrologic soil group of "D". See the attached detailed site plan #2. UNDEVELOPED: Total area is 41,701 sq.ft or.96 acres. The undeveloped condition of the area is all grass or all pervious surface. Land condition Area "n,"1 "ks"2 "CN"3 Grasses .96 .13 11 85 Time of Concentration Calculatipn: Elements of Travel 1. Sheet flow=150 ft slope=2.0% Tc= 0.42(nsk)o.8 (p2)0.$is `0.4 Tc 0.42 0 n L P2 s k Tc= T Tl 0.42 0.13 150 1.4 0.02 11 18.27 T total= 18.27 Ek 4� ,F wns I40 076 27807 OCT 15 1996 igtzisIoNALE0 t© `�' ' BUILDING Ott"i. _ i— 'Puget Sound Stormwater Management Manual Table III-1.4,page 111-1-16. Sheet flow Manning's values. 2Puget Sound Stormwater Management Manual Table III-1.4,page III-1-16. Shallow Concentrated flow values. 3Puget Sound Stormwater Management Manual Table III-1.3,page III-1-12. SCS Western Washington Runoff Curve Numbers. Used soil group"D". 2 DEVELOPED CONDITIONS DRAINAGE ANALYSIS: Total area is 90%impervious or 37,531 sq. ft or.86 acres and 10%pervious(grass)or.1 acres. Land condition Area "m"4 nk5n5 n n6 Grasses .1 .13 11 85 Impervious .86 .011 27 98 Time of Concentration Calculation: Elements of Travel 1. Sheet flow =22 ft slope=2.0% n= .011 2. CPhP Pipe = 210 ft slope=0.5% Kc=42 3. Swale flow=75 ft slope= 1.0% Kc= 17 Tc= 0.42 (11,0.8 Or T=L/60V Where V2 k(S0)vz (P2)0.5(s)0.4 n L P2 s K Tc= T 0,011 12 1.4 0.02 0.34 210 1.4 0.005 42 1.18 75 1.4 0.01 17 0.74 T total= 2.25 For the time of Concentration I will use 2.3 minutes. RUNOFF CALCULATIONS: Design will use the Santa Barbara Urban Hydrograph Method(SBUH)with the use of the King County HYD program. Runoff calculations using the King County HYD Program. Soil Type"D" Precipitation 25 yr. 2.7 inches 100 yr. 3.2 inches Input information PERVIOUS IMPERVIOUS A CN A CN TC UNDEVELOPED .96 85 0 98 18.3 DEVELOPED .1 85 .86 98 2.25 Output Information Peak Flows(cfs) 25 YR. 100 YR. UNDEVFJ OPED .26 .35 DEVELOPED .72 .86 The adjacent undeveloped property between this development and 30th Avenue if developed to 90%impervious will result in a peak 100 year runoff of 2.31 cfs. This is used in the downstream analysis of the basin pipe drainage system. 4 Management Table Ma nning's Sound Stormwater Manage e t Manual ab a III-1.4,page III-1-16. Sheet flow Manning s values. 5Puget Sound Stormwater Management Manual Table III-1.4,page 11I-1-16. Shallow Concentrated flow values, 6Puget Sound Stormwater Management Manual Table III4.3,page III-1-12. SCS Western Washington Runoff Curve Numbers. Used soil group"D". 7Puget Sound Stormwater Management Manual Isopluvial Maps Appendix AIII-1.1,page III-1-43. � � � > � . I V\\ i \ , \ / ,) •azaz)) h r'r--� i • ti ti \;\\ \ '\ \ \\ EXIST. R'DI WATER j/ \ \'\ \ II 0 ;, ' \DUST. 20' ULITITY EASEMENT 1 I \' \ I �`\ \ 1 \ 1, N89'S6'S"W N89'S6'5"W \ II 7UM AT PC \ \\\ I 145.73' �I - - - - - 15O,6T \ _ - - - - :_ . - CA° = 20.00' \ \\� \,\,\ \ \ 1 I \ \ 1 a,ST. SSMH \\\\ I i � I �tV. ELEY.=2•55' \\` ®®®�� \\\\\\\\ 1 111\ I \\ /, , E Our= H /MST. FH 1r \ \. 1 ;�\ V 1 FLOW DOMING DMINAGE/ SHEET FLOW % rA \'\ I DOING \IA I \ \\ ' C• \ \ in q tV m I M C z I 1 \ IV ci ' ' \ I 1 I 1 z ' II il 1 il ,\No' \ \ ' i I 9 / j , r. s I 1 , \ I ; /\ \' \ / ` \ \ \\ \ \ \ I /I ,\ \ ç \\\ \ I \\ \ \ \ N89'S6'5"W N89'56'5"W I i I \-.1 1 \ \\\\\ _ ' —, , / i'�i ' \ \ i74.51 150.68' / \ \\\ \ /9'' I \ EXISTING DRAINAGE �= ' % EXISTING \ \ \ \ OPoMNAGE TO I \\ \,\\ / / / / j PRIVATE SWAGE \ I \N V J / / EXIST. CB TYPE `tAsl. CB TYPE 7 I RIM ELEV=19.93' R/M fGEY.=19.46' li tuTiiiii;,:le, uoin. �-EXIST. C'B TYPE / PRM1:1/E SWAfE NMUEY.=19.48' 1\ ; YARNS 2' \: - • ill I_ p 1 2 �I —' .\ _Ili =1"- \\�, `IY CMP 50 INLC -I I'=1 -1 -I i- 1-1 / \ �\ \ INV IN= 14.02' 41, \ 460 fT FROM Pl.ro CULVERT \\,�\\ iii DITCH SWALE PROFILE / i aria To.CULVERT INLET AT 5/ (�, / \' 7d1N 51REET SGALE NONE / j y4 ER AP • \ ear. B'IN WATER \ I J/4 TER Itx 'I FT/ Earsra mxwEx I 20' ULITITY EASEMENT \ \ I /F/ \ \;;; V\\ Q \ I I N89.56'SW I I N89'56'5'W \ 1 ON AT PC ,\�\, - --0 I 145.73' - - ' - - - - 150.67' CAP=20.00' \\ •\\ \ ` V !i I ICED SURFACE N Lai 1.O.T :_ P ��\\� V\ TON �`N LOA 67 LF d PIN PIPF S=059 FABR16 -,.\-. , v \\ BURmcTov DB BURUNCroN CB g r csrc" \ �, - I . ern,. '55' iie, \\' 11 I jRIM ELEv=26.0' t I RN E1E1s2315' 0 9ry Our \\V. 1 II '.IUN=10.91' - t 5' 'Ao�{ LW=21.25' I l FN \\\\ 1 V r •`/1 "i5�fi�tl // / / /4 sab' ?, I RFMOYE WnN� NIENST. �(ay q\\ "\ I h 2...I I �'' \\\\ V \� FABRIC , 6,000 SF FUTURE 8'RIRUR 6,000 SF --- - N' I �, \�\\� I EXPANSION g'� lj PRE—ENGINEERED STEEL BUILt3�NG j � \ \�, `, \��� �\ ?/ 22'-6" RIDGE HT i/ \ s \',, \\\ , �\ III I I. 24' FINISH FLOOR ELEV. / aI ,S \ ' 1 p fox ANO F0071NG '1 ' / WRNS 'r A\ \\ \ \ N m BORUNOTON CB, // /77 / / / X I 3 EXTENSIONS `� \ \ , i -i RIM ELEY=2,0' / / / / / �/ o '\ \\ - _ _ RN=10.55'I / - / f/ /_ _ N It \ - ® S:Y10'APRON i. L,5 b �p � IyI - — z ` I UR13 ! O \ �� DIICN I uLr, ! I SS YSC 'I EMSj 9 4 , \ \ TO CUL INLET AT 1 4 0°� V o �� III III O� 1 r. o S S c 3 I' 11 P \ \\,FEET O\.Sa05X paoFREq ( Y A°�N \ '\ PARKIN CfC PROFILE I T( IY MOD. CLASS 9 , I L J CM IV ma' 1 I lox,µ I 14 / t. I K \\ \ SLOPE COVERED WI/H ,> E. 'a �'-'8 „ ,' , \\t\� ;ro _ $ za 1z3g zz 7 zo ryi is S le j 15 ,Is 111 I= % Hire.. D ', 1 \' SwNF Ems•=I$B5' \ 6'PVC PPE V / I / Vp li �0I I' I !I \. (IK'')F \\ ` OUR£T 1Bb' 1 / i / I PROfBE a i ,I hi I P� \ SWALE lSFE Prow 1 1-51/1.ar 1 E '� IV I A I.O.S�V TANG 5¢' �V '� Ij I 1 75 � A � J5! • 1I III I \ VAA _A I 1489156'S"W /C PVC PTC.xi�S=03ZT N89'56'S'W L,3 - o -F— BURUNCION CB '`I \1 \\\ \ 74.51' TYPE ! CB RN EIEY TZO' 150.68' - - p pm CURB W/OIL WAffR SEPARA7 / !NY=10.5' \ \ RIM ELEV 220' i \\ \\ \\ 11 I INV-2a7 �;, J\\ N\ \ �DEVELOPED DRAINAGE Pe ��i !(1 \''.. ;u i ^! MST CB TYPE 1 EXIST: C8 TYPE 1 r� �l RTM dEY.=I9.4J' RIM ESEY.=19.46' �C-�i\V ,�//,q;/+W�J•��j�b I oy : \ ew 12 \ 1. \ BLDG3 FIDALG❑ BOAT YARD WOO➢ING I I \ \ 1 TRACT BALLENGER \ \ \ DEVELOPMENT \ 100 YR PEAK FLOW = 1.46 CFS I w 30TH STREET _���� ' w Y 60 - 'a`_ �`��: y I MAX CAPAC TY 6.97CFS �V VIr 44r # '�! 1 > TYPE 1 CSI A4�C �` � a� I UNDEVELOPED I— TYPE IA CH2 ' TYPE II CB3 bq4, GB2 100 YR FI OW —�—_ I BALANGER DEVELOPMENT PEAK FLOW = 1,46 CFS ` TYPE II CB4 C EXISTING SOUTH/WEST DEVELOPMENT PEAK FLOW = 1.50 CFS \ \ � TTy` - I TOTAL FLOW e CBE 3 CFS < 4,7 CFS CAPACITY \ g� 2q ` Q CB3 100 YR FLOW \ g cFS RCS @ 0 ��` 1 pa VOIDING TRACT PEAK FLOW = .68 CFS r$. PROPOSED WISPERING WINDS FLOW = .86 CFS , — c TOTAL FLOW 2 CBS = 3 + .68 + .86 = 4.54 CFS < 9.2 CFS CAPACITY \�, — — -- \\ TYPE LI CB5 \.CAPACRYRCSP 2 0137 30TH STREET ' ` 8'7a CFS TYPE II C87 832 LF 24' RCSP 2 0,15/. NI., 75 LF 30' RCSP SOUTH WEST 'CB4 100 YR FLOW MAX LAHAC1iY = 8./9 CFs DEVELOPMENT TOTTALLSFLOW 2DING CB4 = 4TRACT PEA 59 FL0 6,13 CFS <FS 8.79 CAPACITY _ — — — MAX CA641I CFS \--OUTLET TO BAY 100 YR PEAK FLOW = .68 CFS .\ TYPE II CB6 Z BAY \ POTENTIAL FLOW THROUGH PIPE AT C136= 8.44 < 8.79 CFS CFS c en \ UNDEVELOPED • I 1 a. g 2.9 ACRES o 1 I POTENTIAL OFFSITE FLOW - 2a1 CFS \ CONCLUSION \\ The developed flow for the 100 yr storm event has 1 not exceedED the capacity of the ort5rn•DR+uw;E n7cx ' I existing storm drain system shown. Even with the completion of' the developable area in this basin the I inset10 r Ar I;IrS 1 capacity of the existing pipes will not be reached, \ 460Fur0s-s ' \ a k al"� w SUETY EASEMENT�- - m... - - ai NS PROPOSED DEVLOPMENT •96 ACRES \I r 100 YR PEAK FLOW %���2�.����j � In. X alr B6 CGS �\ , p J m\,\1/4\ (/ 0fF9/E Ll¢YVME M77I( a® -r IV OULIER2 MET Al ' • '�• \ JOINO F SW a aau ( tie \ -RP W -ktram -- 74IN4G OPEN SW IX meomNNW nul i y 100 YR DOWNSTREAM RUNOFF ANALYSIS OF EXISTING STORM DRAIN PIPES TO BAYcnitv;/€.1 "nae:,,,{5,-;P:7;itil- e. HERRIGSTAD ENGINEERING Civil Engineer 3001 R Avenue,Suite 210B Dale Herrigstad,P.E. Anacortes,WA 98221 (360)299-8804 December 6, 1996 Alan Perkes ASI Construction Inc. 1751 Cedardale Road Mount Vernon, WA 98273 Subject: Soil Survey of Whispering Winds Building Site"V"Place, Anacortes, Washington. Dear Alan, The letter is to address the soil bearing capacities for the floor , footings and parking for the Whispering Winds development. The attached log report shows the 3 test holes dug on April 19, 1996 to determine the type of soils on the site. I concur with the soils technician that the soil meets or exceeds the bearing capacity of 1,500 lb/sq ft for the footings and floor design. A suitable pavement cross-section should contain 8" gravel base, 3" ATB and 2"ACP. If you have any questions please let me know. Sincerely, 1 HER/00 ip OF wAsq„N S) it 4 7 Dale Herrigstad,P.E. Sio rs ° / \Z_(b' / rbNAL U [EXPIRES:me J ' n o APRIL 19, 1996 TEST LOGS FOR: WHISPERING WINDS "V" PLACE, ANACORTES, WA I DON'T SEE ANYTHING TO BE CONCERNED WITH FOR THE TYPE OF STRUCTURE YOU ARE PROPOSING. ACCORDING TO THE LOGS WE DID NOT ENCOUNTER ANY GROUND. ALL THE MATERIAL APPEARS TO BE FIRM TO HARD WITH NO MOTTLING RECORDED. GIVEN THE CONDITIONS ONSITE I BELIEVE IN THE AREAS OF UNCONTROOLLED FILL YOU SHOULD ONLY NEED TO REMOVE 12"OF MATERIALS TO FIND A SUITABLE BEARING SURFACE. IN AREA CONTAINING TOPSOIL, REMOVE BEFORE PLACEMENT OF BACK FILL. TEST LOG LOCATIONS ARE AS FOLLOWS: a-IESf PET 3 Ter a Pa" 151 41'Z sci PQopose Bateniiv6 hecET/ad - IGo' tioRYTH " �(" PIRG WHISPERING WINDS SITE "V" PLACE, ANACORTES, WA TEST PIT# I 0 - UNCONTROLLED FILL, HARD TO VERY HARD 2' - SILT, HARD DRY 3' - CLAY, VERY FIRM, MOIST 5' - TEST PIT#2 0 - UNCONTROLLED FILL, SANDY GRAVEL,VERY FIRM a' - CLAY, SILT, FIRM 5' - TEST PIT#3 0- TOPSOIL 2' UNCONTROLLED FILL, SANDY GRAVEL, HARD a' SILT, FIRM, MOIST 6' - HERRIGSTAD ENGINEERING Civil Engineer 300114 Avenue,Suite 210B Dale Herrigstad,P.E. Anacortes,WA 98221 (360)299-8804 December 6, 1996 Alan Perkes ASI Construction Inc. 1751 Cedardale Road Mount Vernon, WA 98273 Subject: Soil Survey of Whispering Winds Building Site"V"Place, Anacortes, Washington. Dear Alan, The letter is to address the soil bearing capacities for the floor , footings and parking for the Whispering Winds development. The attached log report shows the 3 test holes dug on April 19, 1996 to determine the type of soils on the site. I concur with the soils technician that the soil meets or exceeds the bearing capacity of 1,500 lb/sq ft for the footings and floor design. A suitable pavement cross-section should contain 8" gravel base, 3" ATB and 2" ACP. If you have any questions please let me know. Sincerely, HEkRIti J .�� � AQof wnsgi o Prat Dale Herrigstad,P.E. MOT` 96? sysr ?ONALS u EXPIRES:60P1 t )7 APRIL 19, 1996 TEST LOGS FOR: WHISPERING WINDS "V" PLACE, ANACORTES, WA I DON'T SEE ANYTHING TO BE CONCERNED WITH FOR THE TYPE OF STRUCTURE YOU ARE PROPOSING. ACCORDING TO THE LOGS WE DID NOT ENCOUNTER ANY GROUND. ALL THE MATERIAL APPEARS TO BE FIRM TO HARD WITH NO MOTTLING RECORDED. GIVEN THE CONDITIONS ONSITE I BELIEVE IN THE AREAS OF UNCONTROOLLED FILL YOU SHOULD ONLY NEED TO REMOVE 12"OF MATERIALS TO FIND A SUITABLE BEARING SURFACE. IN AREA CONTAINING TOPSOIL, REMOVE BEFORE PLACEMENT OF BACK FILL. TEST LOG LOCATIONS ARE AS FOLLOWS: • TECT en- 3 — — TOT • - 151 4$t T{gI PIT Peo$ossD gaup/NO LocgTo+' NORM " Y" ?LRc.e f H- WHISPERING WINDS SITE "V" PLACE, ANACORTES,WA TEST PIT# I 0 - UNCONTROLLED FILL, HARD TO VERY HARD 2 SILT,HARD DRY 3' - CLAY,VERY FIRM. MOIST 5' - TEST PIT#2 0 - UNCONTROLLED FILL, SANDY GRAVEL,VERY FIRM 4' - CLAY,SILT, FIRM 5' - TEST PIT#3 0- TOPSOIL 2' - UNCONTROLLED FILL, SANDY GRAVEL, HARD 4' - SILT, FIRM, MOIST 1 6' - I FF.OFI : DOEDEKE ( ) P1-101JE 110. : 206 644 5899 �" Oct. 28 1996 12:OOF'11 P2 STRUCTURAL CALCULATIONS for FOUNDATIONS and FLOOR FRAMING WHISPERING WINDS ANACORTES, WA Prepared by 4,C1G G 1, GOEDEKE ENGINEERING �4 17119 SE 47th Court U' , � Bellevue. WA 98006.5805 + a 1„� 1 phone/fax(206) 644-5899 ' 1 1)' 18452 C. Gregg Goedeke, P.E. Ci ,4jGrS-117:'t , k6426NA1.1:N�' '00� 9 EXPIMES• 10/28/90 l HEL;WVkU OCT 2 91996 BUILDING DEPT. FKOH : GOEDEI.E `-- ' PHONE 110. : 206 644 5899 0 Oct. 28 1996 12:00F11 P3 F-a.AnPa.1u W woev.1 .I � . ... _ _ . _. _. IM<<K V 'ftcw' -ars, T Y,ti,x fI k C .4. (141c0c6140 .3 ; PI- + • FIo � ) . c ..I cb = o1ic .�1 tee b ,s1) . slabr, r ,a s ':t-(2 ) z D, 16. .K1t .. .. . . _ . v. 4 sib Cw .4t ate_, 52' SCA beagi wO = I. N ps ►lit . U. .. l I an `.t' ..._:. _I ► II I "1 444,1 P.A r• ° (=14- '. 64,. _ . . . I .. I .. FPO1'I : GOEUEI E \ / PHOIIE 110. : 206 644 5899 C) Oct. 28 1996 12:01PH F4 riik's.'' .41,011/1114,2_ ft- = o 0 I( it tt l ► 1 "Ti a.< =�mr ibis— �1 �1I = " .� I I I I rz CI = Iaiimy Patel 1 r ,0 i"i It1: .m 1 I-. 1 I . . , ' , . [. .. . . ... .. ... I . Tr .� Zs>.(r 1' C _ I I _ _ i . -- - . I , ` I L . . __ _ _ _ -- - -� n it N at "IIIPIIi p .� a AV:: Z 8 pA p �"�, ►-x iI o _ W v K a o ` 1��ill e In 1994 U.H.C. r ti � ^ 411 U 1994 N.R.E.C. ma's :N \ _ . 1I1°�; i,� CITY OF ANACORTES � � u .1 � INDUSTRIAL Pk ra ::',/-,;,. _; H I 44 [ t REQUIRED PROVIDED o ° �, i%``. 2 3 N (7 C-1 N/A rl''11 ^c' L„ ay tal v �' y � �v 1 -0" 15'__Q�, Pk . u � y„�•- O h 101--0" 26'-0n, 74'%-O" 1- C'Aarra.,� �k 10'-0" 36'-O" . _ co • • 6,000 SF FOOTPRINT / 24,160 SF LAND --4-- .25 z O I . . 8,452 SF BLDG / 24,160 SF LAND .35 g ' o FLOOR LOADING (OFFICE) :a Z - . LL 50I$ 80 MPH D.L. 15# a W IT CD z I ription(s) ,g. \ THE EAST 151.00 FEET OF THAT PORTION OF LOT 4, )02, ACCORDING TO THE MAP THEREOF FILED IN BOOK 12 23 AND 24, RECORDS OF SKAGIT COUNTY WASHINGTON, kS SHOWN THEREON, AND ALSO INCLUDING ANY PORTION AS SHOWN THEREON LYING WITHIN SAID NORTH 160.00 (01114 M.p.T LET OF SAID PORTION OF SAID LOT 4 TOGETHER WITH A CHKD )E DRAINAGE EASEMENT ALONG EITHER THE NORTH M.P.T. 3 . DATE IP jICy�lie P08pIt'°brand tax transmittal memo 7671 DRAIMNC NO. 'pia" I AO.1 es°I ct1V-020 • J )ilation Levels for Whisperingnds Based on Envelope Summary, dated 9/26/96 Floor: Concrete slab on grade No perimeter insulation required Second Floor:None Walls: PE steel: 4" R-13 Roof PE steel: 4" R-13 East 1500 sf: Additional 3-1/2" R-11 over PE steel insulation. for a total of R-24. Puncture PE steel vapor barrier. Add poly vapor barrier over R-11 for use as return air space. Doors: Overhead: U-factor of 0.12 or better. Man doors: U-factor of 0.54 or better. Windows: U-factors of 0.60 or better. i N , . cr- c,r` are Aft 4,0 �.•� ��:r ii'. � 9COpe ndory v. �a BOU der OS 0 c9`4y frt,( 1.+ F}pA�pp102 gpY! 5001°1°dA,p,COR�EspF/ <C. „ /v 4S, / O\ `t pN10 )j ----_____ REP if2' -0.e 5 rtu11; \b ^�` J' ti \S • ''' • ' '*:M. 0 • P‘1411 ___— -----_____ . i . \ REP # #. • Vial. t�i > TPN A a ' �•• _•#$O P#9 oA°o �N �Topd -\\56 �'u� �CU�PToperty f r. - i '9y Former �O 160 Noraboard } 60 fEE} plant ' ! 0 40 ,1 '/ / g Oka1""g0 �gU 1e iN / I copaertratton D1a9r°� �'� a/°5/98 }so • n PC9 �..05C E� N°. fro pQQ OM, _..„,coo Wh ® '04 , K9 'sr d d.C1Y._ '0 > 4 sop m9/ V" - • • c.t P '" S d l EXISTING . . , d 4 a �1 -- �„ ■; SWALE EROSION CONTROL NOTES: 1 Pt • RIM ELEV=1948' 1, All exposed soil along City right-of-ways shall be fertilized and reseeded. Time of application and grass Sc S " LIGHT I seed mixture is to be approved by the City of Anacortes. O O O �� EXIST. CB • • • i •- _ 2. Seeding and Fertilizing shaft meet the requirements of Section 8-01.3(4) of said APWA Standard• e e - - . 4 W Specifications. I exams . 3. Contractor shall be responsible far providing erosion control measures at all times as needed, o t ¢i • 4, Additional Erosion control measures may be required at any time- by the City of Anacortes until all excavation t _ a restored to their approval, Contractor is expected to prevent runoff water with sediment from entering the s c : . - - City storm drainage system. �cc F • 5. Contractor is to protect all existing and proposed (immediately after construction) storm sewer inlets ✓= j`c v '\ - "---: \- .,, INLfr •- : - PARCEL RCEj T /A `_ with fitter fabric fences or gravel and wire mesh filters. �� qs f2 CMP SD 1 C] lv �✓ LL Cl 1NV IN = 14.02' �' a' .27 .. ;_ 4ti0 F7 fhY)M PC" T 6. uubruni bcunnenu7uun cunuur 4uucIuIes snail ue in place curing au pnases or site construction and snail TO CULVERT 24 60 SQ. F' I be maintained to the standards se, by the director of Engineering and Development Services. 7 -y Q \ ..: H\- ._ EXISTING FIRE . . K ����� w `� a (ALSO SEE GENERAL NOTES AND OTHER NOTES) C� et c Q HYDRANT TO BE MAINTAINED _ V. 55 ACRES v - ': ACCESSIBLE To PAVING AND GRADING NOTES : sooty _ T - - T B A - - , Thecontractor shall obtain his awn burning -; - • - .R ;,- , - EXIST. 8' DI WATER f 1 permit and ncoo dinateaanypburning with the Ci of Anacortes. Clearing and grubbing shall conform to said • • SITE. EX/S. WATER r_y4-, , , A.P.W.A. Standard Specifications. I r - ',_. 2 0 " UTILITY EASEMENT EX>sT J�4- RATER MErEr;i 1 _ _ 6'S"VI • 6 5"W• t: ; 2. The contractor shall grade the Site to provide subgrade for road, sidewalk and swages suitable to serve the • N89.5 N89'5 I I final grades and typical section estcblished in the plans in accordance with A.P.W.A Standard ^ - r t. �-. ^^ „' .,r �r�+ . _ •r _. r �� - a - Specifications, Division 2. CID 6l'N�NYG7GNl 1YPE7. 4 I 150.8T - k <, , Q `�� f•o �E L 3, This item also includes the placing and compaction of fill according to compaction Method BRIM AYIC s ° l�d�l� \ Compaction shall meet the Standard Specifications of Compaction Method B.�_Re.4$'-0>1 122 LP Q'AC A E s-a5�L' . _ _ h EXIST 6" PVC PIPE 1 C ' . 5-o0p • 0 FENCE DllM�5iER� , �s oar BURLINGTON C8 /"T I EXIST. SS6Ni ` EXIST BURLINGTON CB� I /RIM ELfV.=20,55. \ 4. Overhaul will be considered incidental to the work, f�4 • ,/- RIM fLEV=2J.D" INV. OUT= - RECYCUNG. $=28'-0' RIM ELLV=2J,25' • � j K 1NV. =21.16' EXIST Al 5. Asphalt concretepavement shalt meet the requirements of Division 5 and 9 of W.S,D,O,T- Standard b."�Y. I INV. =21.501 nil P q �� - Specifications- This item shall include the furnishing, heating, hauling, spreading, rolling, and all other work r / <- incidental to fulfillingthe re uiremerts of the Specifications. /4s O . o% N • \` {3�1D 8.rA7 AIM / A 6. The contractor shall coordinate with the City Public Works Department all inspection of work. This d 'i 9 i ' J�A1B includes, but is not limited to, the tompletion of the underground utilities and subgrade, completion of base r L \\ ?a MOD. 9 / LF course and curbing, placement of crushed surfacing course and during the placement of pavement- 1L CO '• . o / q��r �_ \ sant r '*� 47 �� $ EXISTING METAL BUILDING T Cs=. �� � I \ . Pliny EXCAVATION AND FILL ' y 24' FINISH FLOOR ELEV. /" 8 I 31 1. The contractor shall be responsible for locating subsurface improvements/ utilities, and for Cl) _ C �ii a .:` 4 - NEW PRE•�ENGINEERED METAL BUILDING / �i ! I o I coordinating activities with utilities and others. Call before you dig" �_ _4 r-+-4 I. \. ,\ ` , 1 2. Subgrade for pavement sections shall be stripped of all topsoil and other deleterious ti' - �\ (� EXIST. BURL/NGTON C8 f / v 3 material. Following stripping, the exposed subgrade shall be proof rolled with a 10 cubic 0 '� C to 0. *\' ' , I 10 B£RE]A�ED �// ��j / / Wp yard dump truck, 20 ton self-propelled vibratory roller, or equivalent. Soft areas exposed �• en•. Z4 FINISH FLOOR ELEV. N by the proof-rolling, which cannot be easily compacted, shall be over-excavated and ,` ,` -' o COVERED WALK WAY a `a' backfilled with compacted grarutar fill, h '� . s \ - I - I / 1\N \ ' Q� I / 11 I 3. Fill shall beplaced In maximum 8 to 10 inch lifts and thoroughly car acted. Under paved SA \�3_ t _ _ I of subgrade, -+ / ( 9 Y P - ® '� j- areas, the fill shall be CaMpar.ted to 92 percent, except the upper 12 inches bgr k1 - I . rya\ [ AS NLT -� :s ,' 5iJ = whichshallbecompactedtoaninlmurnof95percentofmaximumdrydensity,� �-_ / x lidili :. , \ E'; a ` ��,• - � STORM RAIN NOTES : ►-' ' .. ' -.' ,� ( / ,,_ , i 1" Footing drai s, roof downspouts and curtain drains are to be connected to the storm drainage system or FLUSH INN '6c' �/r - • \ - / I swages as• shown on the construction plans. up. _ T !'f � ;: SIOEINUCl GRADE Drain pipe and fittings may be PVC ASIM D3034 SDI 35 or ADS single wall, fully �\ �fXlSTINC CURB \ BREAK corrugated or equivalent per the recuirements of AASHTO M252 for 3 through 10" diameter. All fittings - (3 : - \ shall be of like material as pipe, All pipe shall be suitable for use as a gravity storm drain conduit. �� ' NIGH-PT var.( `/1 nu \ • \ R�28-0r NEW EXTRUDED CURB \ 2. Down spout drainage systems and easements will remain private with all operations and maintenance ,. r� \\\ .=48'-0„ EXIST, TYPE f CB \ ji 4 I being the responsibility of the owners or others,\ i N., b-y� ` - - EXIST. 644' " PVC P1PE / \ i I 7-Nbr �7RW EDCUR9 GENERAL NOTES : fee' 4 - • �" r-EXLSIJM; AS°INLT EDGE xIrg721 �' N°9^5�,5"Yr ( 39 \ , XIST 8C/ LINCTON ce 27 8 '\ 1 . Ail work shall comply w/ WSDOT/APWA plans & specs, and City of Anacortes STD details. p \ 36 \, i® Lit, INV d21.24' �l', 7.83' NO0.02'30'E 4 ' \ ';- • \co°. - 8.67' N15'32'12£ 24" CPEP T, • . ;1‘ /'--- ill r..el......„,\ E'"4 :; -, ' \ SLOPE I \ \Si FABRIC EXISTING r .la J. _ 8' P/l RUM • DRAINAGE TO 4" ELBOW 30' DIAM �. ��. �\ \. �'�_ CONTROL SEE AWL 1'Yg0. CYASS 9 /� / _ PRIVATE SWALE SOLID LID l� {� EXIST CB TYPE 1 EXIST CB TYPE 1 (11CGILIVAI -::. • SWALE HIGH POINT .'^ -"' \ l/ s17.0' /- - / RIM ELEV.=19.43. RIM ELEV.=19.46' w., \ ct $1._ E IC1 1 CZZ F :?. /� /{/ �� COUPLE WI�via.• V- \ \-mirai DOSTINS ' . . CC . \\. . Y 39. 77 \EXiIMA a CLIO 06 M\`� \\ N / �1 '' 6fi ( • / PROVIDE CHAIN FOR o fir �� .... 1 2 . // ADJUSTMENT OF SHEAR tt s !s tA, \ \ \ i/ 30' DIAM SOLID LID GATE T RIM ELEV,- 21A' 8' SLAB DYER o O f? !S • PARCEL G � �� ' ; / ��' PLAN � w�`� zs \ . ; `,i TYPE II CB 48' WITH a� - PROVIDE HOOK ~t ti w fi 12223 - SCE. FT i > % f �:- :.e� a W RECEIVED RISERS AS NEEDED _ �,. / ' Cm - �, .- - 4' ELBOW WITH 2 1/2' C t 0` 28 d CRES / " w1 ry $EP 2 OVERFLOW ELEV,= 19,72' DIAM, ❑RIFICE I�y �1 w n Es, Cn CO OS� 8 /' awwtN� KEPT STRAP TD CB t �_3 1/4' DIAM.ELBOW I ORIFICE rTH �'' �': �� / ERR _ 4 - r PR ' X / 270. ORIFICE !i3 ELEV.= 18,60' v of *Asti may. z ` N. ❑RIFI[ #2 ELEV•= 18.30" r rE ti c.c Z nr� �^ t /'}�ry�' /y �/ _ _ - - - • .. L Q / - 1 r71 a f, c°2 �" w C/j y�R PHASE: II ' L/CVELUPM�IYr • ,r. -" : ,, W"' 4�. , .. / x H Jf OF ! COUPLE CMP WITH 8 24' DETENTION PIPE r �)/y/( rC `\\ - /tg�'��1.,� `'n SITE PLAN �� 2��a� 99 l o t : :- .` EXISTING IMPERVIOUS AREA - 2�, SCALE: 1 "=20' �� rs, 1 r� ., �j 151 SF tit' EN a o ' � ' DEVELOPED IMPERVIOUS AREA L7, #' INV OUT = 17A0" INV IN = 17.00' V\� A �7 Sr # » d: <Gt. * 8' CMP -� 2' CLF_ANDUT ACCESS W/ DEVELOPED PERVIOUS' AREA G, 639 J t y p'- d,' • �r ' 1 SHEAR GATE AND HANDLE xPIRES 6/02/99 I .. - - _ I f,y - •� SHEET z:I�, i, •�, ,• . ' STRAP TO CB NO. I ,�„> L C 1 I n iY s: • • AE5 11 1D EE DIEIFR81MIiiED . �, - r BASED AM DESIGN OF ADJACEIVP tin - ��.: C STREET at BY RC LYIY 0P/ M ORO • ti 0 - ORIFICE OPENING IN fi Irt1 / t91.2 SIDE DF 8' CMP JOB N0: 55 .. ; �' r \ a • GRAPHIC SGAI E NEwfy{` 20 0 l0 20. 40 ORIFICE = 1 1/8' DIAM, APPROVED Cy UCTION DATE: June 10, 1998 PR ED FOR / �, SCALE: 1 =20' 4 •• PROFIL •E td r 9/�9� DRAWN: D. HEREIGSTAD 5 - ( IN FEET ) CITY ENGINEER CHECE: "n . 1 inch .i 20ft..: • I EER DATE ,: - s 11 ' q, ( l \ SHEET OF X i E 1 V 7 ,,,..........,,,...::, , ss / , if , RA c-4 c4 \Li.I. \\ IA :InelLis 52., , 'N. to TN i `� l7vi/ D/ HOyaly �Obb , \� i 1 L� , 8[ < N�j r.idG „ d0 ` E _ . - 5 8 b� - - it = 10 9.45 N. fV 1 I ( \ z'ss.s8 S 6Z / 7 • ‘ \ Z I1\ / 1 A • \ .....--....-••••••••- f / 1: -- by) ritil III p I PI SiA +2,1/.26, / /II _ — �- — ---- �I/t / -7� — �. I � o N \� , a, I J E - 32 3 9 , h> ip e s J I ��^ W A y r SSMN -{ `L = +46 08 (_ I w N___10.2 4 �21i10 �� g 66'06'44 �/ roPE( f = 32146 4 I ti tit R L � x o /i '� G 310.40 FT o \ ;; t.f CO49;NW9SE j N - 104 %.63 ! ,.9t6s6 t \, A a O 8 S J.Lii / I t 3lON j 33S - r Z\. o b'' » �7 / •,, \ its ,,94'Z s°� �� / - iv I •xoaddv �,., • o G G;dr ' ii S-� R E ST i ,I � N :( 1 / / ..._ 4,0_79 „. 0 ( \ Olss — ...../ ( M� n1• ' ( in i _ • �.� „4,90.99 N + Q Ill -------- I 1 ,i \ is \ 1 A_.......... I �� /7 I / r _ `l7tZZ" �3M3$ �. �� 1/��/ -, ._! �•. . ' O �� �?.T ��/ I--) Imo ) /-\ Ir - -,\ r-- f ♦�'�— /, , .--' ter— — - \ �� I \ I �� I i \ � ' / \ IN I i pe vi- ri: III /-'\ -F-lo .„„ n 4" J N t _ co IPS ` � I I I V/ AI" �A �o� �go 0 / ;TTIe L - A I t 'cief) / \ / I �n NN V , fi � ilt ,J °id 0 nr ', , ` 5 , � rili I N J�� i � � � j 5C'' 14 ,scn�ES C°:,aP = -0+50 \ I \-) �JLII " 5'° (50 - 32436.23 c rIn it I 1 =20' HOR � j (kWr 10596.40 ��� I 0 1" =2' VER OP „ i t I. \ j L ` ( /30.00 30tOC I 28.00 28.00 i 26.00 - - / • 26.OG ; 24.00 �XM 24.0C yV al 41 22.00 N. 22.0C 9 _- p pi ti 20.00 \ai 20.00 a) r✓, o 18.00 N N 18.0C — 1 + 00 —0+ 50 0+ 00 _ 0+ 50 1 + 00 1 + 50 2+ 00 2+50 11 3+00 3+ 50 4+00 4+ 50 I op cn cn ni Leonard,—Boudinot & Skodje Inc. m NOTES PROFESSIONAL ENGINEERS & LAND SURVEYORS 0 1. CONTACT UTILITY LOCATES PRIOR TO ANY EXCAVATION, 4. HORIZONTAL DATUM = BASIS OF BEARING: XREF RCPRFOOI.DWG 603 South First Street; P.O. Box 1 228 PHONE NO. 1-800-424-5555 SHORT PLAT ANA 95-002, FILED IN BOOK XREF 96079TPO.DWG SH• 1 OF 1 Mount Vernon, WA 98273 l0 a M 12 OF SHORT PLATS, AT PAGES 23 AND 24 A STREET IMPROVEMENT TITLE o RECORDS OF SKAGIT CO. WA, 2.THIS SURVEY DOES NOT PURPORT TO SHOW ALLI CITY OF ANACORTES r EASEMENTS, RESTRICTIONS, RESERVATIONS, PROVISIONS, COVENANTS, 5. THIS MAP DOES NOT REPRESENT A BOUNDARY SURVEY. w OR CONDITIONS WHICH MAY AFFECT THE PARCELS SHOWN HEREON. o 3. THIS MAY REPRESENTS FIELD WORK DONE IN APRIL 1998 6. VERTICAL DATUM IS MLLW, JJB 5-6-98 1' = 20 o USC&GS MON BENCH MARK "TIDAL 5" SET AT THE DRWN. DATE: SCALE: LOCATION: o NE CORNER OF OLD RAILROAD DEPOT IN ANACORTES • I n- ELEVATION = 16.981. cc CHK'D. DATE: PROJECT: cc PRH 5-6-98 9gDo APP'D. JEL DATE: DWG. NO. RCP02001.D G REV. o 41......1. REV. DATE DESCRIPTION DWN. CHK. APPR. N 1/2, SECTION 30, T 35 N, R 2 E. , W. M. ROUND MONU1A5NT IN I FOUND MONIAa?ff IN SE AT INTERSECTION tat � GASH INTERSECTION AVENUE ��• q r TRACT 2 "RR�- 4 `T PLATE U. iNACORTES TIDE AND SHORE LANDS N6T 54 05'E av -43�4.�39 - " 56`TSY40"EI > I A I + '� ® \ V\ r T--___\i3, N 69 5'1 05" E 735.251 SEA% arc._'---_--- .S 419.56' I OT © - �i 5 81 59' 40" E 735.07' (PLAT) W 2 o_ y , G _.:3 c _ 9, ;3". W t) \\ v \ Q 7t, \ Si- ' Aw rf \ ri i-- t 7 Fet- FOUND MONUMENT IN CASE ��d ,C�{\ TRACT 3 TRACT 2 -` 30TH STREET LEGAL 34TH ST. - \ \a ACCESS AND DE5CRIrTIONS. AF+Fe9062'ID04a \ 0 tF . �� \ ILITY DETAIL AFte906290047 LEGEND 4 .- ' 1 • - INDICATES IRON ROD 5ET WITH YELLOW CAP MARKED "SKOOJE I9645'\ �' ( A �r { Q - INDICATES FOLIC IRON ROD WITH YELLOW CAP MARKED lEON/IRD 8992' � 2 �� \ ,r'; 9' �' , OT , 9 - INDICATES FOUND MONUMENT AS SHOWN. 04/07/MI5 \ v . TRACT 3 rid 0 - INDICATES FOLNC) REDAR WITH YELLOW CAP MARKED 'KM IC33- \ a 7'1'61 PLATE II. ANACORTES TIDE N ��\\ 4 r GONGRE?E GOAT :9:. \ • - INDICATES FOUND P-K NAIL WITH YELLOW CAP MARKED LECWARD 8492" U :; AND SHORE LANDS �r 741.. .;y A,",•- p +Y, t; ' _' .y�{ \ \ •C3 . nrj�GJ I LOT 3 fr NEW LOT LINE ��� ram, nF:�'• ' ' 2 ;j--'�� 4? E --- v , s ear Q \ 8.40' iC��13 r.`•4(`•'Jc` I `r3d.02'(S e8 07' S8 E 3392.01 ' R) �� (e9.19'R) , 1• ' -, LOT 1 MCI CIE liar SCALE 1'� 100' 'X- 89.15' 'ram - t; N e9' 58' 05" w 384.42' -,"4 8 ?j 3101 "V" PLACE SOUTH Cr Lae p SOUTH C. STREET I + f -- Ma 1.07 ACRES = 46,615 SQ. FT.(S evoe 17. W R) a salon 30' . 20' UTILITY EASEMENT 9.991' �, I , I TRACT 3 w a 89.84' r i► ,/it OLD LOT LME 1 2• 0 50 100 200 y 1 N 89' 58' 05' W 326.40' _ � r J TRACT 4 STREET RIGHTS OF WAY HEREDY f T 184.85' ie4.e1'R 111.00 ' DEDICATED FOR ACCESS OF _�� Z (328.1c 44) i,/' �+ 11 wins- w "'� " ) rs s y N eE11'34 W 12.e7' R ra -� Z CURVE DATA NO UTILITIES aV tw\g6 kr��e la. rc (�ee)oisod� W R) s 2535.1;,eeo7'se" „�+�!a'1 `f'i ' sREBAR IS ON UNE, ;'+30CURVE DELTA RADIUS TANGENT LENGTH �- �► ail a !� �i Sc (137.08'R)(S (ij�1/• W n�IJ �• r fir;. a q 2 0 0.16 SOUTHERLY dt� 'JO �iA\ .I/ �i I o s 'r� 2338• 20 R) n iJc^ �" ip .: OF COMPUTED o OQ 00' ow 4e0A0' O.o1 0A7 ) <" `Ti \ , F,1 n" �" M' R G" PJ •5 °t ( � LOT ), " / CORNER m 03 35' 00' 4e000' DOf 30A2 A, �� R , .� Z 0.57 c. m 3T 35" 36" 460.00' 153.31 314.14' CJ sa .Cr' S SEE I' 1.65 ACRES = 71925 SQ. FT. e ,• �' 30.17' DETAIL 'A , 3115 "V" PLACE r'J 0 33 5'C 56' 4e0A0' 4Q7e' 'L326' �s�� � LOT 4 , -- )' (535.74' N 89 08' 12 E R) ----- �\�' 595.14' 41.4 3T 35 36' 44000' 14t76' 26670' -1 S4 __ , , 1.70 ACRES 330.89' S34.98' N sr 08 53' E (►� EP 31 35' 3e' 44000' N176' 26e70' 0 IS STREET RIGHT OF WAY yd (WITH DEDICATIONS) W ilII��_____ A- 2 27' t7 595.14 , �1 q� ^ `� Hanby mamma 73,906 SQ. FT. tr !W RL1 08 0' (595.74'R) ``\ 0�� �V I t t 70 THE CITY !7F -� ANACORTES FOR ACCRIS 3i16 "V" PLACE,,,,, ,.lt �,1�1s se' 30.. 9 Rio • ` _ I ANO UTILITIES ACROSS \ h . •�.-' N r0 R-1oo.Do' LOT 3 �°' RAILROAD �{ U� �► / .� I L�27.88' 17 �'� ! ''/ ���� ' 4.85 ACRES (WITH DEDICATIONS of^� F. \\ < ` ��5: ,'_ , 2 t 1, 97 SQ. FT. N " DETAIL "A" rr Cj � 1fi. �.s \ \ 3205 "V" PLACE • r � °p Z �' A.F. No. 8905180037 �, IC'`' ' 96 ' 01 ` • �, 'LF J.41 • �� r, ` J t^ (N 89' 59' 40" W R) 41 �?j / �E�� tow / - o i ` 80 STREET RIGHT OF WAY FEJtEDY N 89 59' 26' W 534.49' --_.S -- 5 a1 �->,� • ! DEDICATED TO TIE CITY OF c, ,F,i�. ' (�Y A %'-- g C G7 - .� p f, \ p ANACORTE! FOR ACCESS el: a� (�� W `�"i i I.i \ �\ � p �i ` Al0 UTILITIES {�r v��u `,�,. ^,t� / Q �Of gRti't ,�44 Al. No. 8812280057 �7 �01 7Q a \ LOT LINE TRACT 4 • / / ': :9F 9645 < 60 STREET RIGHT Cr WAY HERESY 1:1 -�� •`. . ... 'p \ s sren;:: �:�` C DEDICATED TO THE CITY OF ANAGOR E �' \_ 82' • - SCMI[ LAN�"'� FOR ACCESS AND UTILITIES ACROSS RAILROAD \ 140 � k ---- S 89' 08' 12' W 728.38' TRACT 5 �.s q �C2 (, ' . `. NEW LOT LINE EXPIRES fj A`/ (Ti' \ 77 '� .� , • 1 ,��� ` . W 4" AS. No. 9303150081 N 18 01' 0e W n� jv� > Jlei J r`, \ N Pt ) '' 71.53' r.nRv `�' AA A. \ Q aC, EAST DOUNDARY LINE OF MEit.A \ /" �` `�� i, ?:i. w aC;�r. J PARKT ADDITONT or �VOL.TES I INDUSTRIAL. IPLATS \ R 100.00'' 00' ?K. S cEmJF CATS PAGE 19 - 21 I\ \ \ / L-84.07' ii• `, I I-EREBY CERTIFY THAT THIS SHORT SUBDIVISION IS BASED ON AN (N 89. 59' 40" w R) \ /�'.t ACTUAL SURVEY, WHICH 15 RETRACEABLE AND BASED ON A TRUE SUB- N89. 59' 28' W _ 140' ; 114.82';'.,M\ -843 09' 00 E p1VlSION OF THE SECTION. THAT 73E DISTANCES, COURSES, AND ANGLES ' ARE SHOWN THEREON CORRECTLY, AND THAT MONUMENTS HAVE SEEN SET ,c` �\ `, eV MOAN?K1T1ls ANb LOT CORNERS STAKED ON TFE GROUNO AS SHOWN ON THE SHORT ACCEj g _ _ 34TH STREET g AF e4o4oeoo5� PLAT IN ACCORDANCE WITH THE PROVISIONS CONTAINED IN CHAPTER . EXHIDIT F - PAGE 2 Cr 2 332-130 WAC. FOUND MONUMENT IN CASE N 89 59' 28" W 783.90' - _- :>AasT 51' 34" (N 89' 59' 40" W 783.99' R) FOUND 1-1/2' IRON PIPE IN CASE • _ R8, O0, j1fuf cl W r L•85.84' s� 80. FILE COPY Q I \ \ \ YSt1 DEDICATED to WAY JEFFREY A SKODJE, P.L.S. / AUDITOR'S C CAS i I I \ CITY OF ANACORTES FOR CERTIFICATE NO. 19645 DATE &/t /cs- SHEET I OF' 2 I \\\ ACCESS NO ACROSS RALROAD TIES /// FILED FOR RECORD T7-115 . DAY OF PA n Ls 3I , 1M95 AT )0,4 I O'CLOCK I I STYWA 5TRREDY DDEEDI .� SHORTOr MAT NNW: A NA 95 - 0 02 DATE: 4-7-3 -et 5 -. M., IN BOOK a OF SHORT PLATS AT GE P.6 a'ff�AT „T�t _RF��)IJEST OF LEONARD, I 1 TO THE CITY OF ANAGORTEs BOUDINOT AND SKOOJE, INC. UNDER AUDITOR'S FILE NO. �7(L)X( JJ(���4t1� FOR ACCESS NO UTILITIES CITY OF ANAGORTES PORTION OF TRACTS 3,4 AND 5, PLATE II, ANACORTES TIDE AND SHORE LANDS, AND A PORTION OF LOT 52 " ANACORTES INDUSTRIAL PARK LOCATED IN THE NORTH 1/2 , SECTION 30, T 35 N. R. 2 E , W.M S AGIT OUVTY UDITOR CITY OF ANACORTES Minn 518 PG. 65'LEONARD, BOUD/NOT and SKODJE, INC. nil I" • D0' I►MGJaq[MAY a��altNO M"I. HI /.A n Ta WNW M1111{CHIN!($.w-all► .ra a 95050