Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0668 3010 Georgia Place 1 ' City of Anacortes Invoice/Permit#: BLD-2021-0668 904 6th Street • Applied date: 08/09/2021 P.O.Box 547 Issue date: 09/20/2021 '0: Anacortes, WA 98221-0547 Expire date: 03/19/2023 ;,''"' 4,r., (360) 293-1901 Job Address: 3010 GEORGIA PL Permit Type: Single Family Residence Permit ANACORTES WA 98221 Project: APN: P108595 Remarks: NEW SFR Owner: BONNIE VANSICKLE Contractor: KREIDER CONSTRUCTION Address: 3708 35TH AVE SW Address: 1010 22ND ST SEATTLE WA 98126 ANACORTES WA 98221-2521 Phone: (206)249-3182 Phone: (360)707-5588 License#: General Information: Fees: Occupancy Group it-1 Plan Application Fee 200.00 Use Zone R2A Building Permit Fee 4,896.25 Flood plain development N Plan Review Fee 3,182.56 New or Replaced Hard Surface 6813 Mechanical Permit Fees 139.40 Lot Area 23344 Plumbing Permit Fee 195.00 1st Floor Square Footage 1763 State Building Code Fee Resi 6.50 2nd Floor Square Footage 1977 Sewer Inspection Fee 52.14 Garage Square Footage 630 Storm Drain GFC-Residential 1,746.97 Deck Square Footage 563 Sewer GFC-Residential 9,331.86 Porch Square Footage 51 Park Impact Fee 615.00 Stove, Appliance 2 Traffic Impact Fee 2,817.69 Building Valuation 850000 Non Sprinklered SFR Fire Fee 102.58 #of Radiant Hydronic Piping 1 EMS Impact Fee 363.70 #of Heat Pumps on 3 Hp 1 SFR/duplex: site plan/design 60.00 Stormwater Review 545.04 #of Tubs, bath 2 #of Clothes Dryers 1 Total Calculated: 24,254.69 #of Clothes Washers 1 Deposits/Receipts: 0.00 #of Dishwashers 1 #_of_Gas Outlets 6 Total Due: 24,254.69 #of Gas Fireplace 1 #of Gas Piping 1 #of Water Piping 2 #of Hose Bibs 4 #of Kitchen Sinks 2 #of Hand Sinks 5 #of Other Mechanical Units 1 #of Range Hoods 1 #of Showers 3 #of utility Sinks 1 #of Ventilation Fans 5 #of Water Closets(Toilets) 4 Y O . City of Anacortes Invoice/Permit#: BLD-2021-0668 904 6th Street Applied date: 08/09/2021 P.O.Box 547 Anacortes, WA 98221-0547 Issue date: 09/20/2021 (360) 293-1901 Expire date: 03/19/2023 C g, The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order, proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. 3e4:64:4 SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY /44,. -1 '''IrdlillitillaWr 1r '. ' r • ,,..,"7'1010004,4,,/ , ' 1..cit, I V% ec,o.VI '1:7014101,s,41V,/ . Finance Department Finance Department 021316-0002 Amber R. 09/27/2021 12:24PM 021316-0003 Amber R. 09/27/2021 12:25PM PERMITS AND INSPECTIONS PERMITS AND INSPECTIONS MARK STONER ARCHITECT LLC MARK STONER ARCHITECT LLC BLD-2021-0668 BLD-2021-0668 Single Family Residence Single Family Residence Permit Permit NEW SFR NEW SFR issued issued 2021 Item: BLD-2021-0668 2021 Item; BLD-2021-0668 Plan Application Fee 200,00 Plan Application Fee 0.00 -, Building Permit Fee 4,896.25 Building Permit Fee 0.00 Plan Review Fee 3,182.56 Plan Review Fee 0.00 Mechanical Permit Fees 139.40 Mechanical Permit Fees 0.00 Plumbing Permit Fee 195.00 Plumbing Permit Fee 0.00 State Building Code Fee State Building Code Fee Resi 6.50 Resi 0.00 Sewer Inspection Fee 52.14 Sewer Inspection Fee 0.00 Storm Drain Storm Drain GFCResidential 1,746,97 GFC-Residential 0.00 Sewer GFC-Residential 6,835,87 Sewer GFC-Residential 2,495.99 Park Impact Fee 0.00 Park Impact Fee 615.00 Traffic Impact Fee 0,00 Traffic Impact Fee 2,817,69 Non Sprinklered SFR Non Sprinklered SFR Fire Fee 0.00 Fire Fee 102.58 EMS Impact Fee 0,00 EMS Impact Fee 363.70 SFR/duplex: site SFR/duplex: site plan/design 0,00 plan/design 60.00 . Stormwater Review 0.00 Stormwater Review 545,04 Payment Id: 329195 Payment Id: 329196 17,254.69 1,000.00 - Subtotal 17,254.69 Subtotal 7,000.00 Total 17,254.69 Total 7,000.00 CHECK 17,254.69 CHECK 7,000,00 Check Number1012 Check Number07062 Change due 0.00 Change due 0.00 Paid by: MARK STONER ARCHITECT LLC Paid by: MARK STONER ARCHITECT LLC 1111311114111111111111111111 • N1iNIIIIMI111111111111 ... ___________ 2018 Washington State Energy Code—Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family—New&Additions(effective February 1,2021) Version 1.0 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings(townhouses). Project Information I I Contact Information VanSickle Residence Mark Stoner, Stoner Architects I 3010 Georgia PI,Anacortes WA 98221 mark@stonerarch.com (206) 284-2205 Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. Authorized Representative 'Date 08/07/2021 All Climate Zones(Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC b,e n/a n/a Ceiling e 49 0.026 Wood Frame Wall g,h 21 int 0.056 Floor 30 0.029 Below Grade Wall`•h 10/15/21 int+TB 0.042 Slab d.f R-Value& Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21+5TB" means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21+5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 2018 Washington State Energy Code-Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family-New&Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: . credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: i credits All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 creaits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Credits-select ONE Options Fuel Normalization Descriptions heating option User Notes P 1 Combustion heating minimum NAECAb 0.0 0 2 Heat pump` 1.0 3 Electric resistance heat only-furnace or zonal -1.0 0 4 DHP with zonal electric resistance per option 3.4 0.5 0 I 5 All other heating systems -1.0 0 I Energy Credits-select ONE Options Energy Credit Option Descriptions energy option from each p category 1.1 Efficient Building Envelope 0.5 0 1.2 Efficient Building Envelope 1.0 0 1.3 Efficient Building Envelope 0.5 0 1.4 Efficient Building Envelope 1.0 0 1.5 Efficient Building Envelope 2.0 0 1.6 Efficient Building Envelope 3.0 0 1.7 Efficient Building Envelope 0 0.5 0 2.1 Air Leakage Control and Efficient Ventilation 0.5 OO 2.2 Air Leakage Control and Efficient Ventilation 1.0 0 2.3 Air Leakage Control and Efficient Ventilation 1.5 0 2.4 Air Leakage Control and Efficient Ventilation 02.0 0 3.1' High Efficiency HVAC 1.0 0 3.2 High Efficiency HVAC 1.0 0 3.3' High Efficiency HVAC 1.5 0 I 3.4 High Efficiency HVAC 1.5 0 3.5 High Efficiency HVAC 1.5 0 3.6a High Efficiency HVAC 0 2.0 ® Hydronic (no heating ducts) 4.1 High Efficiency HVAC Distribution System 0.5 0 4.2 High Efficiency HVAC Distribution System 0 1.0 0 r Prescriptive Path-Single Family 2018 Washington State Energy Code-R 2 2018 Washington State Energy Code—Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family—New&Additions(effective February 1,2021) Summary of Table R406.2(cont.) Energy Credits-select ONE Energy Credit Option Descriptions(cont.) energy option from User Notes Options each category d 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 0 5.3 Efficient Water Heating 1.0 0 5.4 Efficient Water Heating 1.5 0 I 5.5 Efficient Water Heating 2.0 0 I 5.6 Efficient Water Heating 0 2.5 ® IIntegrated w HVAC heat pump 6.1e Renewable Electric Energy(3 credits max) 1.0 0 L 7.1 Appliance Package 0.5 ❑ Total Credits I 6.0 Calculate Total Clear Form a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4)or C403.3.2(5) c. Equipment listed in Table C403.3.2(1)or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may be combined with options 5.2 through 5.6.See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path—Single Family 2018 Washington State Energy Code-R 3 Simple Heating System Size:Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at energycode@energy.wsu.edu or(360) 956-2042 for assistance. I Project Information Contact Information VanSickle Residence Mark Stoner,Stoner Architects 3010 Georgia PI2 1 mark@stonerarchitects.com Anacortes WA 98221 (206)284-2205 M-1 Heating System Type: 0 All Other Systems O Heat Pump To see detailed instructions for each section,place your cursor on the word"Instructions" Design Temperature Instructions Design Temperature Difference(AT) 46 I Anacortes It 0 AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) Average Ceiling Height Conditioned Volume ln,uu,.uuo, Average Ceiling Height(ft) 9.8 36,465 Glazing and Doors U-Factor X Area = UA Instructions U-0.30 I t 0.300 IM 273.30 Skylights U-Factor X Area = UA Instructions 0.50 48 24.00 Insulation Attic U-Factor X Area = UA Instructions 0.026 [ 0 I R-49 NI Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-49 Advanced 0.020 1,977 39.54 Above Grade Walls(see Figure S) U-Factor X Area UA Instructions 0.056 2,211 123.82 I R-21 Intermediate 0 Floors U-Factor X Area UA Instructions rl 0.025 258 6.45 I R-38 L�J Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions 0.064 1,064 68.10 R-10 Continuous Exterior I J Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions I 110 Fully insulated r�l 0.303 86 26.06 Slab on Grade(see Figure 1) F-Factor X _ Length UA Instructionsil Fully Insulated 0.360 104 37.44 Location of Ducts Instructions Duct Leakage Coefficient IIILUnconditioned Space J Ad ) 1.10 Sum of UA 598.70 Envelope Heat Load 27,540 Btu/Hour Figure 1. Sum ofUAxAT Air Leakage Heat Load 18,116 Btu/Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 45,656 Btu/Hour Air leakage+envelope heat loss --low era' Building and Duct Heat Load 50,222 Btu/Hour Ducts in unconditioned space:sum of building heat loss x 1.10 Ducts in conditioned space:sum of building heat loss x 1 Maximum Heat Equipment Output 62,777 Btu/Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07/01/13) 0 Y O PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT • � Mailing Address: P.O. Box 547, Anacortes, WA 98221 1 Office Location: 904 6th Street, Anacortes WA 98821 ` 47 Phone: (360) 293-1901 Residential Building Permit Application Submittal Packet New Single Family Residences (SFR) Duplexes Additions and Remodels (SFR& Duplex) Accessory Dwelling Units Manufactured Homes Residential decks and retaining walls SUBMITTAL CHECKLIST a ,) v a ce �. Residential Building Permit 0 o al F, Submittal Requirement Checklist ce m - c �, a v Y N -a o H = O c 7 a) - C Qy See pages 2-3 of this handout for information about each 3 v v v O E a, c E Q V submittal item listed below. Z , Q o ix •_ 2 x n 2 0 Residential Building Permit Application Form X X X X X (FORM BP-1—attached) Structure &Site Information Form X X X X X (FORM BP-2—attached) Mechanical & Plumbing Fixtures Form X X X (FORM BP-3—attached) Architectural Plans X X X X X (requirements listed on FORM BP-4-attached) Stormwater Management Minimum Requirements Determination X X X X (FORM BP-5,attached) Stormwater Site Plan X X X X Site Plan & Landscape Plans X X X X X (requirements listed on Form BP-6) Structural Plans&Calculations X X X X X Energy Code Plans& Forms X X Manufacturer's Specifications/Cut Sheets X Copy of recorded survey X X X X Technical Reports X X X X Other Required Permits X X X X X ADU Affidavit of Owner Occupancy(signed) X Required Number of Copies and Plan Size Fees 2 paper copies of each item above • Plan review deposit is taken at time of Plans must be minimum 11"x 17",to scale, and legible application submittal. 1 reduced size copy(maximum size 11" X 17") of the Site • Permit fees are paid prior to building Plan, Floor Plan and complete Building Plans permit issuance. Page 1 of 18 I .G �o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 � Phone: (360) 293-1901 REQUIRED SUBMITTAL INFORMATION Additional details on certain submittal items is provided below to ensure Applicants are fully aware what City staff will be looking for when an application is submitted to the City. FORMS AND PLANS • FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION FORM. Provides key information about your project, including type of permit you are applying for, and property owner, contractor, and contact information. • FORM BP-2: STRUCTURE AND SITE INFORMATION FORM. Provides key information about the proposed structure, including height,floor areas, fire protection proposed, and asks questions about site characteristics that are used to determine whether your project requires any other information or additional permit applications to be submitted. • FORM BP-3: PLUMBING AND MECHANICAL INFORMATION. Form BP-3 provides space for you to fill in fixture information for plumbing and mechanical appliances and equipment that are included as part of your project. • FORM BP-4: ARCHITECTURAL PLAN REQUIREMENTS. Form BP-4 contains a list of all the items required to be shown on Architectural Plans. • FORM BP-5: STORMWATER MANAGEMENT DETERMINATION FORM. Most development within the City of Anacortes that involves disruption of soils, or construction of buildings, streets, parking lots, etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed (grading,vegetation removal), or the amount of hard surface that is created or replaced on a site (building footprint, concrete, asphalt or gravel parking, sidewalk, etc.). Form BP-5 assists you in determining the level of stormwater review (applicable Minimum Requirements) required for your project. • STORMWATER SITE PLAN. The Stormwater Site Plan is the comprehensive report containing all of the technical information and analysis necessary for regulatory agencies to evaluate your project for compliance with stormwater requirements. The level of stormwater review and contents of the Stormwater Site Plan will vary with the type and size of the project, and individual site characteristics. Use Form BP-5 to determine the level of stormwater review and then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Engineering Department Forms website and provide required submittal items/plans. • FORM BP-6: SITE PLANS & LANDSCAPE PLANS. Form BP-6 contains a list of all the items required to be shown on Site and Landscape Plans. • STRUCTURAL PLANS: Plans prepared and stamped by a State of Washington licensed professional structural engineer drawn at a scale approved by the Building Official clearly indicating the information required by the "Permits" section of the currently adopted International Building Code and Chapter 19.27 RCW (State Building Code Act, Statewide amendments), and City submittal forms including: structural members labeled as to size and spacing as well as bracing, blocking, bridging, special connectors, and anchor bolts; cross-section details, as needed,to show typical foundation, floor,wall, ceiling and roof construction; insulation of walls,floors and roof/ceiling; and details of stairs, fireplaces and special construction, if any. Res. Building Permit Application Submittal Checklist I II'1r1 t rI flrtr, r�n 7n1Q I .G � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 w� Phone: (360) 293-1901 • STRUCTURAL CALCULATIONS: An analysis of loads, materials, etc., prepared and stamped by a State of Washington licensed professional structural engineer. • ENERGY CODE FORMS: The standard Washington State Energy Office form requesting the information required under Chapter 51-11 WAC detailing building components used to comply with the State Residential or Nonresidential Energy Code, as applicable. • MANUFACTURER'S SPECIFICATIONS/CUT SHEETS: A document that summarized the performance and other technical characteristics of a product, machine, component, material, or subsystem (e.g., a power supply) in sufficient detail that allows the City to determine the product will be incompliance with applicable codes. • COPY OF RECORDED SURVEY. A survey of your property is needed so that conformance with minimum setback requirements and other development standards can been confirmed and verified on site by the inspectors. Property markers must be visible on your property. If they are not at the time an inspection is requested, you may need to have a new survey completed. OTHER SUBMITTALS DETERMINED ON A CASE-BY-CASE BASIS TECHNICAL REPORTS Following is a list of technical reports that will be required to be submitted to the City when certain circumstances exist on or near a site an Applicant is planning on making improvements to. The general triggers for each of the listed technical reports I provided below: A. CRITICAL AREAS REPORTS: In general, Critical Area reports are required when wetlands and/or streams are located on or near a site. Critical area mitigation plans may also be required, depending on the project proposal. See Anacortes Municipal Code Ch. 17.70 for additional information. B. GEOTECHNICAL REPORT: In general, Geotechnical Reports are required when work is proposed on or near slopes in excess of 15%and/or known landslide hazard areas. See Anacortes Municipal Code Ch. 17.70 for additional information. OTHER PERMITS DETERMINED ON A CASE-BY-CASE BASIS OTHER FORMS Following is a list of other permits that could be required in certain circumstances. The general triggers for each of the listed permits is provided below. A. FILL AND GRADE PERMIT: Grading(importing, exporting, and/or moving material on a site) of more than 50 cubic yards and/or if grading modifies the existing flow of stormwater or groundwater. B. RIGHT-OF-WAY PERMIT: A right-of-way permit is required anytime the public right-of-way is disturbed or obstructed in any way by private development or the general public. Res. Building Permit Application Submittal Checklist I Irlrlt.rl nrrrih r in 7n1Q 4y o� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT ;l Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 ` 111Fwi Phone: (360) 293-1901 Page left blank intentionally. Res. Building Permit Application Submittal Checklist I Inrlaterl nrrch r in 7niQ G�ni y 04 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT I Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 ` ' Phone: (360) 293-1901 FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: 3010 Georgia PI P108595 Subdivision/Lot#: Zoning Designation: Lot area (size): 23,344 sf s ft. R2A q 2. TYPE OF PROJECT • New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) ❑ New Duplex ❑ Attached to Primary Unit ❑ Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building ❑ Fence or retaining wall or duplex (new/repair) ❑ Other: Project Summary: Construction of a two-story new Single Family Residence. Project Valuation: $ $850,000 3. PROPERTY OWNER INFORMATION Name: Bonnie VanSickle Phone: 206-249-3182 Address(Street,City,State,Zip): Email Address: 3708 35 th Ave SW Seattle WA 98126 bonnieandsydney@yahoo.com 4. CONTRACTOR INFORMATION Name:* Kreider Construction, Inc. Phone: 360-707-5588 Contractor's Business Licenses State License#: City License#: *All Contractors&Subcontractors must have a valid City CC KREIDCI024PE UBI: 601-887-123 of Anacortes business license prior to doing work in the Expiration Date: Expiration Date: City. 10-30-2021 7-31-2022 Address 1010 22nd St/Anacortes,WA 98221 Email Address: 5. CONTACT PERSON Select one person the city will contact for anything related to this project: Applicant ❑ Property Owner ❑ Contractor ❑ Other(list below) -Name: Mark Stoner/ Stoner Arch. LLC Phone: 206-284-2205 Address(Street,City,State,Zip): Email Address: 2400 E Boston St, Unit 106 mark@stonerarch.com Seattle, WA 98112 Res. Building Permit Application Submittal Checklist I Ir,daterl nrtc,her in 7ni Q I .G � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 1\74 w L Phone: (360) 293-1901 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write"no lenders"on the Name Line below. Name: N /A Phone: N /A Address(Street,City,State,Zip): Email Address: N /A N /A 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: MGS I understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technically complete and sufficient for staff review. MGS I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. MGS I understand and acknowledge that I could be responsible for providing as-built drawings (on paper or electronically) as part of the project's certificate of occupancy process. MGS I understand and acknowledge that Special Inspections could be required as part of my project, and if needed I will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am MGS completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. I understand that if permits are reviewed concurrently such as design review,site plan,traffic MGS concurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. 8-6-2021 Signature Date Mark G Stoner Printed Name Res. Building Permit Application Submittal Checklist I Irlrlt.rl firm,,in 7niq G� y O'er PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT 4;l Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 two Phone: (360) 293-1901 FORM BP-2: STRUCTURE AND SITE INFORMATION 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3010 Georgia PI Anacortes WA 98221 PARCEL P108595 NUMBER(S) 2. DETAILED PROPOSED STRUCTURE INFORMATION Complete the following information as it relates to your project. Mark items that are not applicable with "N/A". Structure height: 26'-6 1/4" AREA SQUARE FOOTAGE OCCUPANCY GROUP CONSTRUCTION TYPE OCCUPANT LOAD 1st Floor: 1,763 sf R3 V-B N/A 2nd Floor: 1,977 sf R3 V-B N/A 3rd Floor: N/A N/A N/A N/A Basement: N/A N/A N/A N/A Garage: 630 sf R3 V-B N/A Total deck: 563 sf R3 V-B N/A Total porch: 51 sf R3 V-B N/A Other: N/A N/A N/A N/A Other: N/A N/A N/A N/A Other: N/A N/A N/A N/A 3. QUESTIONS ABOUT THE PROPOSED STRUCTURE Is a fire sprinkler system being installed? ❑ YES NO Is a monitored fire alarm being installed? ❑ YES NO Are retaining wall(s) being built? YES ❑ NO Are structural plans required? YES ❑ NO 4. PROJECT SITE INFORMATION A. Is work within the City's right-of-way proposed? If yes, you will be required ❑ YES NO to submit a right-of-way permit application. If you have already submitted a ROW permit, list the permit number here: B. Is the property located in a flood zone? ❑ YES NO If yes, list the flood zone designation: C. Are there slopes in excess of 15%on or abutting the site? If yes, a � YES ❑ NO geotechnical report will likely need to be submitted. Res. Building Permit Application Submittal Checklist NOTE: Per site feasibility phone call with City of Anacortes, Undated nrtnhpr in 7ni npntp.(.hnir'al rRnnrt WAS CiP.tP.rminP.Ci not rP.ntjimrt_ I .G � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 '\ woI Phone: (360) 293-1901 D. Are there critical areas or buffers on or abutting (within 300-feet of)the ❑ YES NO project site? If yes, a critical areas report will likely need to be submitted. E. Is the lot less than 5,000 sq. ft. in area? ❑ YES NO If yes,your site and building will need to comply with the standards in AMC 19.43.010.C. F. Is your project involving an accessory dwelling unit? ❑ YES NO If yes,your site and building will need to comply with the standards in AMC 19.47. G. Will more than 2-acres be cleared and/or more than 5,000 board feet ❑ YES • NO (about 1 log truck load) of timber be harvested? If so you may need to obtain a forest practices permit from DNR. H. Is this project subject to the SEPA process? If yes,you will be required to ❑ YES • NO submit a SEPA checklist. If you have already completed the SEPA process, list the permit number here: 5. REQUIRED SIGNATURE I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects,true, correct, and complete to the best of knowledge and belief. 8-6-2021 Signature Date Mark G Stoner Printed Name Res. Building Permit Application Submittal Checklist I Irlrlt.rl nrrrlh r in 7n1Q G� y o� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT lllok Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 lc ol w� Phone: (360) 293-1901 FORM BP-3: PLUMBING AND MECHANICAL FIXTURES lir 1. ill MECHANICAL Equipment Type: Appliance/Equipment Information (new and relocated): Total #: Furnace: Gas#: Elec#: BTU: Other#: Wall Heater: Gas#: Elec#: Other: #: Gas Water #: Location(s): Heat Pump: Elec#: 1 Other#: Capacity: Mechanical room 1 Air Conditioning: Elec#: Other#: Capacity: Radiant/Hydronicc Gas#: Elec#: 1 Other:#: entire floor, both floors 1 Exhaust Fans: Bath It: 4 Laundry#: 1 Other: See plans 5 Range Hood: #: 1 Location(s): Kitchen 1 Fireplace: Gas#: 2 Elec#: Other:#: Living room, basement 2 Clothes Dryer& Duct: Gas#: Elec#: 1 Other: It Laundry 1 Stove/Range/Oven: Gas#: 1 Elec#: 1 Other: #: Kitchen 2 _Gas Piping/Outlet(s): #: 3 Location(s): patio fire pit, lower patio, deck Boiler Gas#: Elec#: BTUs: Other: #: Location(s): TOTAL MECHANICAL OUTLETS: PLUMBING Fixture Type(new and Total#: Fixture Type(new and relocated): Total #: relocated): Water Closet(Toilet): 4 Refrigerator water supply(for water/ice 1 Kitchen Sink: 2 Pressure Reduction Valve/Pressure Regulator: Utility Sink: (incl. dog wash station) 1 Water Service Line: 1 Tub: 2 Water Piping: Hand Sink: 5 Clothes Washer: 1 Shower: 3 Electric Water Heater: Tank-less? Yes ❑ Dishwasher: 1 Backflow Prevention Assembly: Hose Bib: 4 Other: House heat pump will also heat potable hot 1 water storage tank TOTAL PLUMBING FIXTURES: Res. Building Permit Application Submittal Checklist I Indaterl nrtc h r in 7ni q G�'T y o� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT I Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 'rC) Phone: (360) 293-1901 FORM BP-4: ARCHITECTURAL PLAN REQUIREMENTS Ir 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3010 Georgia PI Anacortes WA 98221 PARCEL P108595 NUMBER(S) 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant architectural plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11" x 17" and drawn in an architectural scale. • Architectural plans for structures 4,000 square feet or larger are required to be prepared and stamped by an architect licensed in the State of Washington. • Structural plans must be stamped by a structural engineer licensed in the state of Washington. 3. REQUIREMENTS FOR ALL ARCHITECTURAL PLANS COMPLETE REQUIREMENTS PAGE#ON ? YOUR PLANS Cover(or 1st page) must include: • Site address • Parcel number Yes • Lot number(if applicable) A0.0 • Lot size • Lot coverage • % impervious surface coverage Yes Floor plans with existing (if applicable) and proposed building layout with square A1.4, A1.5 footages and with the use of each room/area labeled. Window and door sizes labeled and window ventilation area. Commercial, A1.4,A1.5, Yes Multi-Family, and Mixed-Use Structures must also include door and window schedules. A5.1 Yes Plumbing, duct, and electrical layout. Penetration protection must be shown. A1.4, A1.5 Yes Opening headers, size, and material. S2.2, S2.3 Cross section details, showing typical foundation,floor, wall, ceiling and roof Yes construction and insulation. A4.1 Yes Structural members labeled as to size and spacing as well as bracing, blocking, S2.1, S2.2, bridging, special connectors, and anchor bolts. S2.3 Yes Details documenting energy code compliance. A0.0 Yes Exterior building elevations demonstrating compliance with applicable structure A2.1,A2.2, type design standards (small lot, duplex, or ADU) and maximum building height A2.3, A2.4 Res. Building Permit Application Submittal Checklist I IIIfI�t d fl ,,h,r in 7nia I .G � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 � Phone: (360) 293-1901 Building height(see AMC 19.42.120 for measurement methods,exceptions and modifications). • Label the building height at the highest point of the structure from the average of the natural topography at the foundation at the front of the building. • Label the average elevation of the natural topography at the front of the A2.1,A2.2, Yes building. A2.3, A2.4 • Label the elevation at the center of all exterior walls of the proposed building. • For ADUs only, include elevations demonstrating compliance with the height/setback plane(see AMC 19.47.030(C)(6)). N /A Special details as needed (i.e., stairs,fireplaces, special construction). N /A Yes Insulation and insulation values of walls, slab,floors, and roof/ceiling. A0.0,A4.1 Yes Existing and proposed grades with slope of lot shown. A3.1, A3.3 Res. Building Permit Application Submittal Checklist I Inrl�tcrl rirtnhcr 1(1 7(11Q I .G �o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 w� Phone: (360) 293-1901 FORM BP-5: STORMWATER MANAGEMENT MINIMUM REQUIREMENTS DETERMINATION 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3010 Georgia PI Anacortes WA 98221 PARCEL NUMBER(S) P108595 2. GENERAL INFORMATION Most development within the City of Anacortes that involves disruption of soils,or construction of buildings, streets, parking lots,etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed (grading,vegetation removal),or the amount of hard surface that is created or replaced on a site(building footprint,concrete,asphalt or gravel parking,sidewalk,etc.) This form is largely targeted for small projects and single family residences. For larger projects and more information please refer to the Anacortes Municipal Code(Chapter 19.76 Stormwater Management)and the latest Washington State Department of Ecology Stormwater Management Manual for Western Washington (Ecology Manual). 3. HARD SURFACE AREA CALCULATION Please calculate your project's hard surface amount;guidance is provided on the next page of this document. Use your project's total hard surface calculation to follow the flow chart(s) in this packet and determine the level of stormwater management required for you project. When determining your permit level or if stormwater thresholds are met or exceeded the entire project must be considered. A project is that portion of a property, properties,or right of way subject to land disturbing activities, new hard surfaces and replaced hard surfaces. The hard surface on your property will determine the storm water utility fees and the stormwater general facility charge. All new or replaced hard surfaces should be accounted for. Below are excerpts from the Anacortes Municipal Code and Ecology Manual that may assist you in preparing this information. "Hard surface area"means an impervious surface, a permeable pavement,or a vegetated roof. "Impervious surface"means a non-vegetated surface area which either prevents or retards the entry of water into the soil mantle as under natural conditions prior to development. A non-vegetated surface area which causes water to run off the surface in greater quantities or at an increased rate of flow from the flow present under natural conditions prior to development. "Replaced impervious surface"means,for structures, the removal and replacement of impervious surfaces down to the foundation. For other impervious surfaces, the removal down to bare soil or base course and replacement. Res. Building Permit Application Submittal Checklist I Ir,d tcrl(lrt, her 1(1 /n1Q I . .et PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 � Phone: (360) 293-1901 Land disturbance Description Total (SF) Total Area of Land disturbing activity 11,556 sf Total area converted from vegetation to 3,714 sf lawn or landscaped areas Hard surface area calculation Existing Removed Proposed Proposed Description (SF) (SF) Replaced New (SF) (SF) Non Pollution Generating Hard Surface Area 0 sf 0 sf 0 sf 5,152 sf (Sidewalks, paths, patios,etc.) Pollution Generating Hard Surface Area 0 sf 0 sf 0 sf 1,661 sf (Driveways, parking areas, etc.) Total Hard Surface 0 sf 0 sf 0 sf 6,813 sf Site Size 23,344 sf Existing impervious surface coverage% 29.2% (sq.ft. hard surface/site size) Use the information in the above table to navigate the flow chart(s) on the next page and determine the applicable stormwater management minimum requirements for your project. Then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Engineering Department Forms website and provide required submittal items/plans. Check applicable box Minimum Requirements Determination Minimum Requirements#1-9. Minimum Requirements #1-5. Res. Building PerrrrEt Application Submittal Checklist I Ird tcrl rlrtnhcr /nica Minimum Reauirement#2. PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 ��t'� w� Phone: (360) 293-1901 FLOW CHART FOR DETERMINING REQUIREMENTS FOR NEW DEVELOPMENT Start Here Does the site have 35% Yes See Redevelopment Minimum or more of existing ► Requirements and Flow Chart impervious coverage? (Figure I-2,4,2). No Does the project convert 3/4 acres or more of vegetation to Does the project result in lawn or landscaped areas,or 5,000 square feet,or No convert 2.5 acres or more of greater,of new plus I. native vegetation to pasture? replaced hard surface area? No Yes Yes Does the project result in 2,000 square feet,or greater,of new plus All Minimum Requirements replaced hard surface area? apply to the new and replaced hard surfaces and converted Yes No vegetation areas. Does the project have land Minimum Requirements#1 disturbing activities of 7,000 through#5 apply to the new Yes square feet or greater? and replaced hard surfaces and the land disturbed. No w Minimum Requirement#2 applies. r,� Figure 1-2.4.1 Flow Chart for Determining Requirements for 641 New Development DEPARTMENT OF Revised June2015 ECOLOGY Please see http://wwwecywa.govicopyright.html for copyright notice including permissions, State of Washington limitation of liability,and disclaimer. Res. Building Permit Application Submittal Checklist I Inrl�tcrl(lrtnhcr in /n1Q I .G �o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT • Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 � Phone: (360) 293-1901 FLOW CHART FOR DETERMINING REQUIREMENTS FOR REDEVELOPMENT Does the project result in 2,000 square feet,or more,of new plus replaced hard surface area? OR Does the land disturbing activity total 7,000 square feet or greater? Yes No Minimum Requirements#1 through#5 apply to the new and replaced hard Minimum Requirement#2 applies. surfaces and the land disturbed. jr Next Question Does the project add 5,000 square feet or more of new hard surfaces? OR Convert%4 acres or more of vegetation to lawn or landscaped areas? OR Convert 2.5 acres or more of native vegetation to pasture? Yes No V All Minimum Requirements apply Next Question Is this a road to the new hard surfaces and the 0related project? No converted vegetation areas. Yes Does the project add 5,000 square feet or more of new hard surfaces? Yes No Is the total of new plus replaced hard surfaces Do the new hard 5,000 square feet or more, surfaces add 50%or No No additional No AND more to the existing requirements. I does the value of the proposed improvements hard surfaces within -including interior improvements-exceed the project limits? 50%of the assessed value(or replacement value)of the existing site improvements? Yes' • All Minimum Requirements apply to the new and replaced ' hard surfaces and converted vegetation areas. Yes Figure 1-2.4.2 Flow Chart for Determining Requirements for Redevelopment DEPARTMENT OF Revised June2015 ECOLOGY Please see http;//www ecy.we,gov/copyrighthfml for copyright notice including permissions, State of Washington limitation of liability,and disclaimer Res. Building Permit Application Submittal Checklist I ir,d tcrl rlrtnhcr in /n1Q I � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 � Phone: (360) 293-1901 FORM BP-6: SITE PLAN REQUIREMENTS 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: 3010 Georgia PI Anacortes WA 98221 PARCEL P108595 NUMBER(S) 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant site plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11" x 17" and drawn in an engineering or architectural scale. 3. INFORMATION REQUIRED ON ALL SITE PLANS COMPLETE? REQUIREMENTS PAGE#ON YOUR PLANS Cover sheet must contain all of the following: • Vicinity Map • Name of the project • Name, address, and telephone number of owner and agent(s) • Name, address, and telephone number of Applicant (if different from the owner) Yes • Zoning designation of the site A0.0,A1.1 • Area, in square feet and acreage, of the project site • Reference to the Building Code used • Proposed use • Occupancy group • Construction type • Square footage and height of each individual building • Percent lot coverage • Percent impervious surfaces Yes Scale and North Arrow A1.1 Property features: Location, identification, and dimensions of all property lines and Yes easements. All easements shown on the title report, Record of A1.1 Survey, or plat must be dimensioned and shown. N /A Location and dimensions of existing critical areas (wetlands, streams, N /A steep slopes) and their associated buffers. N /A Location of Ordinary High Water Mark and shoreline jurisdiction limits N /A (if adjacent to a shoreline). Existing and proposed contours and site elevations (i.e.finished Yes grades) at 5-foot minimum increments. The horizontal and vertical A1.1 control datum must be clearly shown. Res. Building Permit Application Submittal Checklist I Ir,d tcrl(lrtnhcr in 7nio I G �o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 � Phone: (360) 293-1901 Structures: Yes Location, identification, dimensions and size of all existing and A1.1 proposed buildings and other structures. Yes Location of existing and proposed retaining walls, rockeries, and A1.1 Yes Location, identification, and dimensions of all setbacks. A1.1 Show proposed projections into required setbacks, including Yes dimensions (see AMC 19.44.140) A1.1 Utilities & Easements: Location and dimensions of existing and proposed stormwater, sanitary sewer, potable water, and fiber lines/facilities. All wells and Yes septic systems located on or near the project site must also be A1.1 identified. Location of all existing and proposed fire hydrants within 300 feet of Yes the boundary of the project site. A1.1 Location and dimensions of existing and proposed freestanding Yes lighting fixtures, utility junction boxes, public utility transformers. A1.1 Stormwater Proposed Temporary Erosion and Sediment Control Measures, if not Yes located on other plans. Cl Yes Proposed permanent stormwater management BMPs. Cl Access, Circulation & Parking Location, identification, and dimensions of all existing and proposed Yes on-site and adjacent streets and alleys, including the location and A1.1 dimensions of all existing and proposed curbs,gutters, sidewalks, median islands, and street trees. Show existing and proposed vehicular access to the site, including the Yes size and location of driveways and curb cuts. A1.1 Yes Show existing and proposed parking spaces, including surface material Al.1 and dimensions of spaces. Open Space (ADUs, Small Lots, and Duplexes) Show calculations, location, dimensions and provided square footage N /A of required open space area per AMC 19.43.010.C, E, or AMC 19.47, N /A as applicable. Landscaping Show the location and design of landscape areas to be preserved and Yes planted, and a plant list to include the location, number, size and type A1.2 of plant material by botanical and common name. N /A Location of irrigation system if a permanent or temporary system is N /A proposed. Show the location of existing trees to be retained in conformance Yes with AMC 16.50, and tree protection measures to be implemented, A1.2 when applicable. Res. Building Permit Application Submittal Checklist I Ir,d tcrl(lrtnhcr in 7nio I .G � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 w� Phone: (360) 293-1901 Provide a maintenance plan for any infiltration-based stormwater N /A best management practices (BMPs) built as part of the landscaping N /A design, including the specifications and maintenance procedures of any soil amendments. Show new trees to be planted and tree unit credit calculations, in Yes conformance with AMC 16.50 Tree preservation,when applicable A1.2 The following table,with project specific information filled in, must be placed on the site plan: Required Landscaping For Example Calculations Site Area 7,500 sq.ft. of site area to be landscaped (per 20%- R2A zone AMC Tables 19.42.020-.030) 1,500 sq.ft. required 1,850 sq.ft. provided Compliance with AMC Ch. 16.50 Tree unit credits required: Tree Preservation. • 8 tree units required Tree unit credits retained: • 2 trees 6"dbh=4 tree unit credits retained Tree unit credits provided: • 2 new deciduous trees(min. 2" caliper @ 6"above ground) • 2 new evergreen trees(8' in height) Number of required street trees 1 per 30'of frontage 60 lineal feet of frontage=3 street trees Res. Building Permit Application Submittal Checklist I Ir,d tcrl(lrtnhcr in 7nio 5� i \� i C_r ."--- ---:---- / \ \ \\ *42. '2\" \ \ ROCK �� ss �® \ BLACKBERRY 1. ROCK WALL ,— ZiN ENCROACHMENT LEG -\D 0 4" PVC SD k ,,,i EXIST. '' - 1 " CPE`J'� FENCE x x S STUB 176.��� G PIPE DISCHARGE X S �, GAS /� 18\ oj" UNDERGROUND ucP G��* PN�CF.P V, POWER S E ��N EXIST. SANITARY \\ 9Z�S S EF�'� - FENCE ON SEWERA SS ��\\\�\� CONC. WALL 790_ �� STORM / -- �o P108595 - �_ SEWER SD $ I Georgia 195- WATER W � MAIN �s Place Catch Basin �• ��200— rxi EO a Sanitary Sewer Man Hole '9 �� 2.05- �` Fire Hydrant Water Gate Valve 210- Water Meter EDGE i 215 —. CPB�� 10' UTILITIES EASEMENT ROCK = • •, �- - - - - -LANDSCAPIi �� 2,20 — FF�`. 0 G GECORGIA PL. FOUND REARPC-\\\\ 0 AND CAP R=215.00' 1000 L=35.20' D=9°22'48" R=147.00' L=77.68' j D=30°16'33" HERRIGSTAD ENGINEERING & SURVEYING 2010 GEORGIA PLACE DATE SITE TOPOGRAPHY SURVEY FOR ROB & JEANNETTE 3-12-2020 4320 WHISTLE LAKE ROAD SCALE: ANACORTES, WA 98221 299-8804 PAPDAKIS NOTED